1
|
Mo X, Cui Y, Yuan J, Hang Z, Jiang X, Duan G, Liang L, Huang Z, Li S, Sun P, Chen W, Wei L, Guo Y, Deng D. Study on a new "One-stop-shop" scan protocol combining brain CT perfusion and head-and-neck CT angiography by using 256-detector CT for stroke patients. Eur J Radiol 2022; 154:110426. [PMID: 35797790 DOI: 10.1016/j.ejrad.2022.110426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 03/20/2022] [Accepted: 06/24/2022] [Indexed: 12/30/2022]
Abstract
PURPOSE We sought to evaluate the performance of a new "one-stop-shop" scan protocol combining brain computed tomography perfusion (CTP) and head-and-neck CT angiography (CTA) imaging for acute stroke patients using a 256-detector CT scanner. METHOD From March to August 2020, 60 patients (30 men and 30 women) aged 22-88 years with suspected acute stroke were enrolled and randomly divided into 2 groups to undergo brain CTP and head-and-neck CTA with a 256-detector CT system. Group A used traditional scan protocol with a separate brain CTP and head-and-neck CT examination that included non-contrast-enhanced and contrast-enhanced acquisitions; group B used the new "one-stop-shop" scan protocol with head-and-neck CTA data inserted into brain CTP scans at the peak time (PT) of the arterial phase. The insertion point of the head-and-neck CTA data was determined by a test bolus. The examination time, contrast dose, radiation dose, and image quality were compared between the groups. RESULTS The total contrast dose was reduced by 40% in group B compared to group A (60 mL vs. 100 mL). The imaging time was 52.5 ± 2.6 s in group B and 74.9 ± 3.3 s in group A, showing a reduction of approximately 43% in group B. There was no significant difference in image quality both quantitatively and qualitatively between the groups (all P > 0.05). Group B had a slight reduction in dose length product (1139.0 ± 45.3 vs. 1211.6 ± 31.9 mGy·cm, P < 0.001). CONCLUSIONS The proposed "one-stop-shop" scan protocol combining brain CTP and head-and-neck CTA on a 256-detector CT system can reduce imaging time and contrast dose, without affecting image quality or perfusion results, compared to the traditional protocol of separating the examinations.
Collapse
Affiliation(s)
- Xiaping Mo
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Yu Cui
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Jie Yuan
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Zufei Hang
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Xueyuan Jiang
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Gaoxiong Duan
- Department of Radiology, The People's Hospital of Guangxi Zhuang Autonomous Region, Nanning 530021, Guangxi, China
| | - Lingyan Liang
- Department of Radiology, The People's Hospital of Guangxi Zhuang Autonomous Region, Nanning 530021, Guangxi, China
| | - Zengchao Huang
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Shasha Li
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Peiyi Sun
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Wei Chen
- Department of Neurology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Lanzhen Wei
- Department of Radiology, First Affiliated Hospital, Guangxi University of Chinese Medicine, Nanning 530023, Guangxi, China
| | - Ying Guo
- GE Healthcare, Computed Tomography Research Center, Beijing 100176, China
| | - Demao Deng
- Department of Radiology, The People's Hospital of Guangxi Zhuang Autonomous Region, Nanning 530021, Guangxi, China.
| |
Collapse
|
2
|
Chen PA, Chen CW, Chou CC, Fu JH, Wang PC, Hsu SH, Lai PH. Impact of 80 kVp with iterative reconstruction algorithm and low-dose contrast medium on the image quality of craniocervical CT angiography. Clin Imaging 2020; 68:124-130. [PMID: 32592973 DOI: 10.1016/j.clinimag.2020.05.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 05/08/2020] [Accepted: 05/27/2020] [Indexed: 11/19/2022]
Abstract
PURPOSE To assess the image quality of 80-kVp craniocervical CT angiography (CCCTA) protocol combined with adaptive statistical iterative reconstruction-V (ASIR-V) and low-dose contrast medium (CM). METHODS A total of 119 patients were randomly divided into three groups. For group A, 120-kVp protocol was followed with 60 ml CM and filtered back projection; for group B, 80-kVp protocol with 60 ml CM and ASIR-V; and for group C, 80-kVp protocol with 45 ml CM and ASIR-V. Both subjective and objective image quality and radiation doses were evaluated. RESULTS Arterial attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the head, neck, and shoulder regions were significantly higher in groups B and C compared with group A. Group C yielded significantly better subjective image quality than that observed in groups A and B (both p < .05). As compared with group A, effective radiation dose and the iodine load of group C were reduced by 51.4% and 25%, respectively. CONCLUSIONS The CCCTA protocol with 80 kVp, ASIR-V, and 45 ml of CM injected at 3 ml/s significantly reduced the radiation dose, iodine load, and iodine delivery rate while providing better subjective and objective image quality, including higher arterial enhancement and a higher SNR and CNR compared with the 120-kVp protocol.
Collapse
Affiliation(s)
- Po-An Chen
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan
| | - Chih-Wei Chen
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan
| | - Chiung-Chen Chou
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan
| | - Jui-Hsun Fu
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan
| | - Po-Chin Wang
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan
| | - Shuo-Hsiu Hsu
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan
| | - Ping-Hong Lai
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan.
| |
Collapse
|
3
|
Hsiao CC, Chen PC, Kuo PC, Ho CH, Jao JC. Assessment of image quality and dose in contrast-enhanced head and neck CT angiography of New Zealand rabbit. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2020; 28:739-750. [PMID: 32597826 DOI: 10.3233/xst-200669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
BACKGROUND Although computed tomography (CT) is a powerful diagnostic imaging modality for diagnosing vascular diseases, it is some what risky to human health due to the high radiation dosage. Thus, CT vendors have developed low dose computed tomography (LDCT) aiming to solve this problem. Nowadays, LDCT has gradually become a main stream of CT examination. OBJECTIVE This study aimed to assess the feasibility of LDCTAin an animal model and compare the imaging features and doses in two clinical scanners. METHODS Twenty-two New Zealand rabbit head and neck CTA images pre- and post-contrast agent injection were performed using256-sliceand 64-slice CT scanners. The tube voltages used in the 256-slice and the 64-slice CTA were 70 kVp and 80 kVp, respectively. Quantitative images indices and radiation doses obtained from CTA in these two scanners were compared. RESULTS More neck arterial vessels could be visualized in multi-planar reconstruction (MPR) CTA on the 256-slice CT scanner than on the 64-slice CT scanner. After contrast agent injection, all observed neck arterial vessels had higher CT numbers in 256-slice CTA than in 64-slice CTA. There was no significant difference in contrast-to-noise (CNR) of CTA images between these two scanners. CT dose index (CTDI) and dose length product (DLP) for the 256-slice CTA were lower than those for the 64-slice CTA. CONCLUSIONS Low dose CTA of rabbits with 70 or 80 kVp is feasible in a 256-slice or a 64-slice CT scanner. The radiation dose from the 256-slice CTA was much lower than that from the 64-slice CTA with comparable SNR and CNR. The technique can be further applied in longitudinal monitoring of an animal stroke model in the future.
Collapse
Affiliation(s)
- Chia-Chi Hsiao
- Department of Radiology, Kaohsiung Veterans General Hospital, Taiwan, R.O.C
| | - Po-Chou Chen
- Department of Biomedical Engineering, I-Shou University, Taiwan, R.O.C
| | - Pei-Chi Kuo
- Department of Biomedical Engineering, I-Shou University, Taiwan, R.O.C
| | - Chih-Hao Ho
- Department of Medical Imaging, Taipei City Hospital (Yangming Branch), Taiwan, R.O.C
| | - Jo-Chi Jao
- Department of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, Taiwan, R.O.C
| |
Collapse
|