1
|
Mollaee S, Fuentes-Aguilar RQ, Huegel JC, Budgett DM, Taberner AJ, Nielsen PMF. A pneumatic reconfigurable socket for transtibial amputees. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3801. [PMID: 38185908 DOI: 10.1002/cnm.3801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 11/06/2023] [Accepted: 12/07/2023] [Indexed: 01/09/2024]
Abstract
Many transtibial amputees rate the fit between their residual limb and prosthetic socket as the most critical factor in satisfaction with using their prosthesis. This study aims to address the issue of prosthetic socket fit by reconfiguring the socket shape at the interface of the residual limb and socket. The proposed reconfigurable socket shifts pressure from sensitive areas and compensates for residual limb volume fluctuations, the most important factors in determining a good socket fit. Computed tomography scan images are employed to create the phantom limb of an amputee and to manufacture the reconfigurable socket. The performance of the reconfigurable socket was evaluated both experimentally and numerically using finite element modelling. The study showed that the reconfigurable socket can reduce interface pressure at targeted areas by up to 61%.
Collapse
Affiliation(s)
- Saeed Mollaee
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Rita Q Fuentes-Aguilar
- Institute of Advanced Materials for Sustainable Manufacturing, Tecnologico de Monterrey, Zapopan, Mexico
| | - Joel C Huegel
- School of Engineering and Sciences, Tecnologico de Monterrey, Zapopan, Mexico
| | - David M Budgett
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Andrew J Taberner
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
- Department of Engineering Science and Biomedical Engineering, The University of Auckland, Auckland, New Zealand
| | - Poul M F Nielsen
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
- Department of Engineering Science and Biomedical Engineering, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
2
|
Cullen S, Mackay R, Mohagheghi A, Du X. 3D Motion Analysis for the Assessment of Dynamic Coupling in Transtibial Prosthetics: A Proof of Concept. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2023; 4:141-147. [PMID: 38274781 PMCID: PMC10810304 DOI: 10.1109/ojemb.2023.3296978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 05/09/2023] [Accepted: 07/10/2023] [Indexed: 01/27/2024] Open
Abstract
Assessment of coupling between transtibial sockets and users is historically based on clinicians' observations and experience, but can be inaccurate and unreliable. Therefore, we present a proof of concept, for five out of six possible degrees of freedom coupling metric system for a socket, using motion analysis calibrated on a 3D printed limb substitute. The method is compatible with any socket suspension method and does not require prior modifications to the socket. Calibration trials were used to locate the axis of rotation of the knee joint referenced against a marker cluster on the thigh; this allowed for the identification of the limb during test trials despite the entire residuum being obscured from view by the socket. The error in the technique was found to be within 0.7 mm in displacement and 0.7 degrees in rotation, based on the control data. Dynamic testing showed the Inter Quartile Range (IQR) of inter time step variance was <0.5 mm/deg for all metrics. The method can form a basis for objective socket evaluation, improve clinical practice and the quality of life for amputees.
Collapse
Affiliation(s)
- Sean Cullen
- Department of Mechanical and Aerospace Engineering, College of Engineering, Design and Physical SciencesBrunel University LondonUB8 3PHUxbridgeU.K.
| | - Ruth Mackay
- Department of Mechanical and Aerospace Engineering, College of Engineering, Design and Physical SciencesBrunel University LondonUB8 3PHUxbridgeU.K.
| | - Amir Mohagheghi
- Division of Sport, Health & Exercise Sciences, College of Health, Medicine and Life SciencesBrunel University LondonUB8 3PHUxbridgeU.K.
| | - Xinli Du
- Department of Mechanical and Aerospace Engineering, College of Engineering, Design and Physical SciencesBrunel University LondonUB8 3PHUxbridgeU.K.
| |
Collapse
|
3
|
Armitage L, Cho K, Sariyildiz E, Buller A, O’Brien S, Kark L. Validation of a Custom Interface Pressure Measurement System to Improve Fitting of Transtibial Prosthetic Check Sockets. SENSORS (BASEL, SWITZERLAND) 2023; 23:3778. [PMID: 37050838 PMCID: PMC10099032 DOI: 10.3390/s23073778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 03/31/2023] [Accepted: 04/04/2023] [Indexed: 06/19/2023]
Abstract
Achievement of fit between the residual limb and prosthetic socket during socket manufacture is a priority for clinicians and is essential for safety. Clinicians have recognised the potential benefits of having a sensor system that can provide objective socket-limb interface pressure measurements during socket fitting, but the cost of existing systems makes current technology prohibitive. This study will report on the characterisation, validation and preliminary clinical implementation of a low cost, portable, wireless sensor system designed for use during socket manufacture. Characterisation and benchtop testing demonstrated acceptable accuracy, behaviour at variable temperature, and dynamic response for use in prosthetic socket applications. Our sensor system was validated with simultaneous measurement by a commercial sensor system in the sockets of three transtibial prosthesis users during a fitting session in the clinic. There were no statistically significant differences between the sensor system and the commercial sensor for a variety of functional activities. The sensor system was found to be valid in this clinical context. Future work should explore how pressure data relates to ratings of fit and comfort, and how objective pressure data might be used to assist in clinical decision making.
Collapse
Affiliation(s)
- Lucy Armitage
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Kenny Cho
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Emre Sariyildiz
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Angela Buller
- Orthopaedic Appliances, Pty, Ltd. (OAPL), Alexandria, NSW 2015, Australia
| | - Stephen O’Brien
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Lauren Kark
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
- Tyree Foundation Institute of Health Engineering, University of New South, Sydney, NSW 2052, Australia
| |
Collapse
|
4
|
Armitage L, McDonald KA, Kark L, Buller A, Ford B. Transtibial prosthetic socket fitting: Australian prosthetist perspectives on primary challenges, management strategies, and opportunities for workflow and technological innovation. Prosthet Orthot Int 2023; 47:194-203. [PMID: 36112475 DOI: 10.1097/pxr.0000000000000174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 05/31/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND Following transtibial amputation, a custom-built socket is the most common interface between the prosthesis and residual limb. Desire from both prosthetists and prosthesis users for improved socket fitting processes have been well documented. However, there is currently limited information available about prosthetists' experiences of how prosthetic manufacturing workflow can contribute to socket fit problems. OBJECTIVES This study aims to determine how socket fit problems are currently detected and managed by prosthetists and to identify challenges, management strategies, and opportunities for workflow and technological innovation during prosthesis manufacture and socket fitting. STUDY DESIGN Mixed-method (quantitative and qualitative) survey. METHODS An online survey was developed and piloted in consultation with members of the Australian Orthotic Prosthetic Association. The final 25-question survey was distributed through their membership database. Mixed methods were used to analyze survey items. Qualitative items were grouped and coded under themes relating to challenges, management strategies, and opportunities. Quantitative data were analyzed using nonparametric descriptive methods. RESULTS Twenty-three respondents with a range of experience completed the survey. Seven of eight major Australian states/territories were represented. Primary workflow stages presenting challenges with limited strategies/solutions available to the prosthetists were roll-on liner selection, mold or cast modifications, communication with the client, and check socket fitting. Suggested solutions included improved socket-limb interface monitoring technology. CONCLUSIONS This study provides the first insights into prosthetist-identified challenges and limitations at different stages of the socket workflow and presents a starting point for more targeted research into innovation that may assist in these processes.
Collapse
Affiliation(s)
- Lucy Armitage
- School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, New South Wales, Australia
| | - Kirsty A McDonald
- School of Health Sciences, University of New South Wales, Sydney, New South Wales, Australia
| | - Lauren Kark
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - Angela Buller
- Orthopaedic Appliances Pty. Ltd, Sydney, New South Wales, Australia
| | - Belinda Ford
- Health Systems Science, The George Institute for Global Health, University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
5
|
Optimal design and 3D printing of prosthetic socket based on the interface pressure between the socket and residual limb. Prosthet Orthot Int 2023; 47:87-93. [PMID: 35511448 DOI: 10.1097/pxr.0000000000000147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 03/16/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND At present, the quantifiable pressure distribution at the interface between the socket and stump is seldom applied in the design and fabrication of the socket. OBJECTIVES This study aimed to optimize the socket based on the interface pressure of residual limb-socket, thereby avoiding excessive local load on the residual limb, reducing the load on the pressure-sensitive (PS) regions and making the limb more evenly loaded. METHODS The residual limb was divided into the main load-bearing regions, the pressure-tolerant regions, and the PS regions according to the carrying capacity at its different regions. Based on these bearing regions, a mathematical function was developed, which applied modifications/adjustments to the socket design in a Computer Aided Design (CAD) environment by using the adjustment function. Besides, three adjusted sockets were produced by using selective laser sintering 3D printing technology. RESULTS The wearing of the 3D-adjusted printed sockets reduced the contact interface pressures in the distal tibial region and the fibular head region by 85.6% and 84.4%, respectively. In addition, the walking distance of the subject was increased by 18.34%, and the overall pressure distribution on the stump became more uniform. CONCLUSIONS The pressures in the original overpressure regions and the PS regions could reduce, whereas the pressure in the low-load regions of main load-bearing or pressure-tolerant regions could increase by modifying the socket with the pressure adjustment function. At the same time, the pressure among different regions was more uniform except for the sensitive regions.
Collapse
|
6
|
Cullen S, Mackay R, Mohagheghi A, Du X. The Use of Smartphone Photogrammetry to Digitise Transtibial Sockets: Optimisation of Method and Quantitative Evaluation of Suitability. SENSORS (BASEL, SWITZERLAND) 2021; 21:8405. [PMID: 34960503 PMCID: PMC8703273 DOI: 10.3390/s21248405] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 11/28/2021] [Accepted: 12/12/2021] [Indexed: 11/17/2022]
Abstract
The fit of a lower limb prosthetic socket is critical for user comfort and the quality of life of lower limb amputees. Sockets are conventionally produced using hand-crafted patient-based casting techniques. Modern digital techniques offer a host of advantages to the process and ultimately lead to improving the lives of amputees. However, commercially available scanning equipment required is often expensive and proprietary. Smartphone photogrammetry could offer a low cost alternative, but there is no widely accepted imaging technique for prosthetic socket digitisation. Therefore, this paper aims to determine an optimal imaging technique for whole socket photogrammetry and evaluate the resultant scan measurement accuracy. A 3D printed transtibial socket was produced to create digital and physical twins, as reference models. The printed socket was photographed from 360 positions and simplified genetic algorithms were used to design a series of experiments, whereby a collection of photos were processed using Autodesk ReCap. The most fit technique was used to assess accuracy. The accuracy of the socket wall volume, surface area and height were 61.63%, 99.61% and 99.90%, respectively, when compared to the digital reference model. The scanned model had a wall thickness ranging from 2.075 mm at the top to 7.758 mm towards the base of the socket, compared to a consistent thickness of 2.025 mm in the control model. The technique selected did not show sufficient accuracy for clinical application due to the degradation of accuracy nearer to the base of the socket interior. However, using an internal wall thickness estimation, scans may be of sufficient accuracy for clinical use; assuming a uniform wall thickness.
Collapse
Affiliation(s)
- Sean Cullen
- Department of Mechanical and Aerospace Engineering, College of Engineering Design and Physical Sciences, Brunel University, Kingston Lane, Uxbridge UB8 3PH, UK; (R.M.); (X.D.)
| | - Ruth Mackay
- Department of Mechanical and Aerospace Engineering, College of Engineering Design and Physical Sciences, Brunel University, Kingston Lane, Uxbridge UB8 3PH, UK; (R.M.); (X.D.)
| | - Amir Mohagheghi
- Sport, Health & Exercise Sciences, College of Health, Medicine and Life Sciences, Brunel University, Kingston Lane, Uxbridge UB8 3PH, UK;
| | - Xinli Du
- Department of Mechanical and Aerospace Engineering, College of Engineering Design and Physical Sciences, Brunel University, Kingston Lane, Uxbridge UB8 3PH, UK; (R.M.); (X.D.)
| |
Collapse
|
7
|
Rankin K, Steer J, Paton J, Mavrogordato M, Marter A, Worsley P, Browne M, Dickinson A. Developing an Analogue Residual Limb for Comparative DVC Analysis of Transtibial Prosthetic Socket Designs. MATERIALS 2020; 13:ma13183955. [PMID: 32906701 PMCID: PMC7557588 DOI: 10.3390/ma13183955] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 09/01/2020] [Accepted: 09/02/2020] [Indexed: 12/18/2022]
Abstract
Personalised prosthetic sockets are fabricated by expert clinicians in a skill- and experience-based process, with research providing tools to support evidence-based practice. We propose that digital volume correlation (DVC) may offer a deeper understanding of load transfer from prosthetic sockets into the residual limb, and tissue injury risk. This study’s aim was to develop a transtibial amputated limb analogue for volumetric strain estimation using DVC, evaluating its ability to distinguish between socket designs. A soft tissue analogue material was developed, comprising silicone elastomer and sand particles as fiducial markers for image correlation. The material was cast to form an analogue residual limb informed by an MRI scan of a person with transtibial amputation, for whom two polymer check sockets were produced by an expert prosthetist. The model was micro-CT scanned according to (i) an unloaded noise study protocol and (ii) a case study comparison between the two socket designs, loaded to represent two-legged stance. The scans were reconstructed to give 108 µm voxels. The DVC noise study indicated a 64 vx subvolume and 50% overlap, giving better than 0.32% strain sensitivity, and ~3.5 mm spatial resolution of strain. Strain fields induced by the loaded sockets indicated tensile, compressive and shear strain magnitudes in the order of 10%, with a high signal:noise ratio enabling distinction between the two socket designs. DVC may not be applicable for socket design in the clinical setting, but does offer critical 3D strain information from which existing in vitro and in silico tools can be compared and validated to support the design and manufacture of prosthetic sockets, and enhance the biomechanical understanding of the load transfer between the limb and the prosthesis.
Collapse
Affiliation(s)
- Kathryn Rankin
- Bioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK; (K.R.); (J.S.); (J.P.); (A.M.); (M.B.)
- µ-VIS X-Ray Imaging Centre, University of Southampton, Southampton SO17 1BJ, UK;
| | - Joshua Steer
- Bioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK; (K.R.); (J.S.); (J.P.); (A.M.); (M.B.)
| | - Joshua Paton
- Bioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK; (K.R.); (J.S.); (J.P.); (A.M.); (M.B.)
| | - Mark Mavrogordato
- µ-VIS X-Ray Imaging Centre, University of Southampton, Southampton SO17 1BJ, UK;
| | - Alexander Marter
- Bioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK; (K.R.); (J.S.); (J.P.); (A.M.); (M.B.)
| | - Peter Worsley
- Skin Health Research Group, School of Health Sciences, University of Southampton, Southampton SO16 6YD, UK;
- Institute for Life Sciences, University of Southampton, Southampton SO17 1BJ, UK
| | - Martin Browne
- Bioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK; (K.R.); (J.S.); (J.P.); (A.M.); (M.B.)
- Institute for Life Sciences, University of Southampton, Southampton SO17 1BJ, UK
| | - Alexander Dickinson
- Bioengineering Science Research Group, School of Engineering, University of Southampton, Southampton SO17 1BJ, UK; (K.R.); (J.S.); (J.P.); (A.M.); (M.B.)
- Institute for Life Sciences, University of Southampton, Southampton SO17 1BJ, UK
- Correspondence: ; Tel.: +44-(238)-059-5394
| |
Collapse
|
8
|
Agcayazi T, Menguc Y, Reese S. Skin in the Game: A Tunable Interface-Quality Sensor for Human-Coupled Accessories. IEEE SENSORS LETTERS 2020; 4:1-4. [DOI: 10.1109/lsens.2020.3011864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|