Engelen MM, Verhamme P, Vanassche T. Clotting of the Extracorporeal Circuit in Hemodialysis: Beyond Contact-Activated Coagulation. Semin Nephrol 2023; 43:151473. [PMID: 38233291 DOI: 10.1016/j.semnephrol.2023.151473] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
Thrombotic complications in patients with end-stage kidney disease are frequent. While being a lifesaving treatment for these patients, hemodialysis introduces a thromboinflammatory environment. Additionally, the extracorporeal hemodialysis circuit itself is prone to clotting because of an interaction between different activation mechanisms of the coagulation system, platelets, and the immune system. Anticoagulation of the patient and the machine is frequently complicated by bleeding. We discuss the factors important in this balancing act and touch on potential strategies that are on the horizon to target thromboinflammation.
Collapse
Affiliation(s)
- Matthias M Engelen
- Department of Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium; Center for Molecular and Vascular Biology, Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.
| | - Peter Verhamme
- Department of Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium; Center for Molecular and Vascular Biology, Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium
| | - Thomas Vanassche
- Department of Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium; Center for Molecular and Vascular Biology, Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium
| |
Collapse
|
2
|
Jonsson P, Stegmayr C, Stegmayr B, Forsberg U. Venous chambers in clinical use for hemodialysis have limited capacity to eliminate microbubbles from entering the return bloodline: An in vitro study. Artif Organs 2023. [PMID: 36594759 DOI: 10.1111/aor.14495] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/24/2022] [Accepted: 12/27/2022] [Indexed: 01/04/2023]
Abstract
BACKGROUND During hemodialysis (HD), blood passes through an extracorporeal circuit (ECC). To prevent air administration to the patient, a venous chamber (chamber) is located before the blood return. Microbubbles (MBs) may pass through the chamber and end up as microemboli in organs such as the brain and heart. This in vitro study investigated the efficacy of various chambers in MB removal. MATERIALS AND METHODS The in vitro recirculated setting of an ECC included an FX10 dialyzer, a dextran-albumin solution to mimic blood viscosity and chambers with different flow characteristics in clinical use (Baxter: AK98 and Artis, Fresenius: 5008 and 6008) and preclinical test (Embody: Emboless®). A Gampt BCC200 device measured the presence and size of MBs (20-500 μm). Percentage change of MBs was calculated: ΔMB% = 100*(outlet-inlet)/inlet for each size of MB. Blood pump speed (Qb) was 200 (Qb200) or 300 (Qb300) ml/minute. Wilcoxon paired test determined differences. RESULTS With Qb200 median ΔMB% reduction was: Emboless -58%, AK98 -24%, Fresenius 5008 -23%, Artis -8%, and Fresenius 6008 ± 0%. With Qb300 ΔMB% was: Emboless -36%, AK98 ± 0%, Fresenius 5008 ± 0%, Artis +25%, and Fresenius 6008 + 21%. The Emboless was superior to all other chambers with Qb200 and Qb300 (p < 0.001). Further, the Emboless with Qb300 still eliminated more MBs than all other chambers with Qb200 (p ≤ 0.003). CONCLUSION The results from the present study indicate that flow characteristics of the chamber and the Qb are important factors to limiting exposure of MB to the return bloodline. The Emboless chamber reduced MBs more effective than those chambers in clinical use investigated.
Collapse
Affiliation(s)
- Per Jonsson
- Department of Public Health and Clinical Medicine, Umea University, Umea, Sweden
| | - Christofer Stegmayr
- Department of Public Health and Clinical Medicine, Umea University, Umea, Sweden
| | - Bernd Stegmayr
- Department of Public Health and Clinical Medicine, Umea University, Umea, Sweden
| | - Ulf Forsberg
- Department of Public Health and Clinical Medicine, Umea University, Umea, Sweden
| |
Collapse
|
3
|
Raina R, Sethi S, Khooblall A, Kher V, Deshpande S, Yerigeri K, Pandya A, Nair N, Datla N, McCulloch M, Bunchman T, Davenport A. Non-anticoagulation pediatric continuous renal replacement therapy methods to increase circuit life. Hemodial Int 2022; 26:147-159. [PMID: 34989465 DOI: 10.1111/hdi.13003] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 12/20/2021] [Accepted: 12/21/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Acute kidney injury (AKI) is a clinical condition characterized by an abrupt increase in serum creatinine levels due to functional changes in the kidneys from a newfound insult or injury. For supportive treatment, continuous renal replacement therapy (CRRT) is one of the most widely used modalities due to its precise control of fluid balance over extended periods of time. However, its complications include circuit clotting, the most frequent cause for CRRT interruption. Vascular access and circuit management were found to be major determinants of performance efficiency. Anticoagulation required to prevent clotting has the downside of increasing the risk of bleeding, especially in the setting of overdosage. Hence, a delicate balance needs to be maintained consistently. METHODS This study explores the adequacy of non-anticoagulation measures in the prevention of circuit clotting. A comprehensive literature search was conducted using PubMed/Medline and Embase databases to include all relevant studies. FINDINGS The most-effective CRRT catheter would be made of nonthrombogenic material, noncuffed and nontunneled with separate lumens for arterial and venous blood. Further, studies show that blood flow during the process is optimized at 200 ml/min, which can be lowered in the pediatric population due to more narrow catheters. Platelet count and hematocrit need to be closely monitored as levels above 450,000 × 106 /L and 0.40, respectively, increase risk of clotting. Predilution is a non-anticoagulation technique to reduce the risk of clotting by returning replacement solution to the blood before it reaches the filter. Also, biocompatible membranes such as polyacrylonitrile or polysulfone activate the coagulation cascade significantly less than the conventional cellulose-based membranes, thereby reducing clotting chances. DISCUSSIONS With the advent of such techniques and maneuvers, anticoagulation can be efficiently maintained in patients undergoing CRRT without increasing the risk of bleeding.
Collapse
Affiliation(s)
- Rupesh Raina
- Akron Nephrology Associates, Cleveland Clinic Akron General Medical Center, Akron, Ohio, USA.,Department of Nephrology, Akron Children's Hospital, Akron, Ohio, USA
| | - Sidharth Sethi
- Pediatric Nephrology, Kidney Institute, Medanta, The Medicity Hospital, Gurgaon, Haryana, India
| | - Amrit Khooblall
- Akron Nephrology Associates, Cleveland Clinic Akron General Medical Center, Akron, Ohio, USA.,Department of Nephrology, Akron Children's Hospital, Akron, Ohio, USA
| | - Vijay Kher
- Pediatric Nephrology, Kidney Institute, Medanta, The Medicity Hospital, Gurgaon, Haryana, India
| | - Shweta Deshpande
- Akron Nephrology Associates, Cleveland Clinic Akron General Medical Center, Akron, Ohio, USA.,Department of Nephrology, Akron Children's Hospital, Akron, Ohio, USA
| | - Keval Yerigeri
- Department of Medicine, Northeast Ohio Medical University, Rootstown, Ohio, USA
| | - Aadi Pandya
- Akron Nephrology Associates, Cleveland Clinic Akron General Medical Center, Akron, Ohio, USA.,Department of Nephrology, Akron Children's Hospital, Akron, Ohio, USA
| | - Nikhil Nair
- Akron Nephrology Associates, Cleveland Clinic Akron General Medical Center, Akron, Ohio, USA.,Department of Nephrology, Akron Children's Hospital, Akron, Ohio, USA
| | - Nithin Datla
- Akron Nephrology Associates, Cleveland Clinic Akron General Medical Center, Akron, Ohio, USA.,Department of Nephrology, Akron Children's Hospital, Akron, Ohio, USA
| | - Mignon McCulloch
- Red Cross War Memorial Children's Hospital, University of Cape Town, Cape Town, South Africa
| | - Timothy Bunchman
- Pediatric Nephrology & Transplantation, Children's Hospital of Richmond at VCU, Richmond, Virginia, USA
| | - Andrew Davenport
- University College London Centre for Nephrology, Division of Medicine, University College London Medical School, Royal Free Hospital, London, UK
| |
Collapse
|
4
|
Goto J, Forsberg U, Jonsson P, Matsuda K, Nilsson B, Nilsson Ekdahl K, Henein MY, Stegmayr BG. Interdialytic weight gain of less than 2.5% seems to limit cardiac damage during hemodialysis. Int J Artif Organs 2020; 44:539-550. [PMID: 33339470 PMCID: PMC8366174 DOI: 10.1177/0391398820981385] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Aims: To investigate if a single low-flux HD induces a rise in cardiac biomarkers and if a change in clinical approach may limit such mechanism. Material and methods: A total of 20 chronic HD patients each underwent three different study-dialyses. Dialyzers (low-flux polysulfone, 1.8 sqm) had been stored either dry or wet (Wet) and the blood level in the venous chamber kept low or high. Laboratory results were measured at baseline, 30 and 180 min, adjusted for the effect of fluid shift. Ultrasound measured microemboli signals (MES) within the return line. Results: Hemodialysis raised cardiac biomarkers (p < 0.001): Pentraxin 3 (PTX) at 30 min (by 22%) and at 180 min PTX (53%), Pro-BNP (15%), and TnT (5%), similarly for all three HD modes. Baseline values of Pro-BNP correlated with TnT (rho = 0.38, p = 0.004) and PTX (rho = 0.52, p < 0.001). The changes from pre- to 180 min of HD (delta-) were related to baseline values (Pro-BNP: rho = 0.91, p < 0.001; TnT: rho = 0.41, p = 0.001; PTX: rho = 0.29, p = 0.027). Delta Pro-BNP (rho = 0.67, p < 0.001) and TnT (rho = 0.38, p = 0.004) correlated with inter-dialytic-weight-gain (IDWG). Biomarkers behaved similarly between the HD modes. The least negative impact was with an IDWG ⩽ 2.5%. Multiple regression analyses of the Wet-High mode does not exclude a relation between increased exposure of MES and factors such as release of Pro-BNP. Conclusion: Hemodialysis, independent of type of dialyzer storage, was associated with raised cardiac biomarkers, more profoundly in patients with higher pre-dialysis values and IDWG. A limitation in IDWG to <2.5% and prolonged ultrafiltration time may limit cardiac strain during HD, especially in patients with cardiovascular risk.
Collapse
Affiliation(s)
- Junko Goto
- Institute of Public Health and Clinical Medicine, Division of Medicine, Umeå University, Umeå, Sweden.,Department of Emergency and Critical Care Medicine, School of Medicine, University of Yamanashi, Yamanashi, Japan
| | - Ulf Forsberg
- Institute of Public Health and Clinical Medicine, Division of Medicine, Umeå University, Umeå, Sweden.,Department of Internal Medicine, Skellefteå County Hospital, Skellefteå, Sweden
| | - Per Jonsson
- Institute of Public Health and Clinical Medicine, Division of Medicine, Umeå University, Umeå, Sweden
| | - Kenichi Matsuda
- Department of Emergency and Critical Care Medicine, School of Medicine, University of Yamanashi, Yamanashi, Japan
| | - Bo Nilsson
- Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
| | - Kristina Nilsson Ekdahl
- Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden.,Linnaeus Centre of Biomaterials Chemistry, Linnaeus University, Kalmar, Sweden
| | - Michael Y Henein
- Institute of Public Health and Clinical Medicine, Division of Medicine, Umeå University, Umeå, Sweden
| | - Bernd G Stegmayr
- Institute of Public Health and Clinical Medicine, Division of Medicine, Umeå University, Umeå, Sweden
| |
Collapse
|
5
|
Forsberg U, Jonsson P, Stegmayr B. Air contamination during medical treatment results in deposits of microemboli in the lungs: An autopsy study. Int J Artif Organs 2019; 42:477-481. [PMID: 30973284 DOI: 10.1177/0391398819840363] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
INTRODUCTION Microbubbles of air may enter into patients during conventional hemodialysis, infusions of fluids, or by injections. The aim of this study was to investigate whether the air that enters the patient during hemodialysis can be detected in the lungs after death, and if so, whether this may be related to tissue damage. METHODS The material consisted of lung tissue from five chronic hemodialysis patients who died either during (two) or after hemodialysis (range 10 min from start until 3333 min after the last hemodialysis session); as reference group tissue was taken from seven patients who died due to amyotrophic lateral sclerosis. The lung tissue was investigated by microscopy after autopsy using a fluorescein-marked polyclonal antibody against fibrinogen as a marker for clots preformed before death. RESULTS All five hemodialysis patients had microbubbles of air in the lung tissue, whereas two of seven amyotrophic lateral sclerosis patients had such findings (Fisher's test p = 0.0278, relative risk = 3.5, confidence interval: 1.08-11.3). There were more microbubbles of air/10 randomly investigated microscopic fields of tissue in the hemodialysis patients than the amyotrophic lateral sclerosis patients (Student's test, p < 0.05). All hemodialysis patients had a medium graded extent of pulmonary fibrosis that was not found in any of the ALS patients. The microbubbles of air were surrounded by fibrin as a sign of development of clots around the air bubbles while the patients were still alive. CONCLUSION Exposure to microbubbles of air during various treatments such as hemodialysis may result in microemboli. Future studies should clarify whether microbubbles of air contribute to tissue scarring. We suggest preventive measures against the exposure to microbubbles of air during especially repeated exposures such as hemodialysis.
Collapse
Affiliation(s)
- Ulf Forsberg
- 1 Department of Public Health and Clinical Medicine, Skellefteå Research Unit, Umeå University, Umeå, Sweden
| | - Per Jonsson
- 2 Department of Public Health and Clinical Medicine, Faculty of Medicine, Umeå University, Umeå, Sweden
| | - Bernd Stegmayr
- 2 Department of Public Health and Clinical Medicine, Faculty of Medicine, Umeå University, Umeå, Sweden
| |
Collapse
|
6
|
Stegmayr BG. Sources of Mortality on Dialysis with an Emphasis on Microemboli. Semin Dial 2016; 29:442-446. [DOI: 10.1111/sdi.12527] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- Bernd G. Stegmayr
- Department Public Health and Clinical Medicine; Division of Nephrology; Umeå University; Umeå Sweden
| |
Collapse
|
7
|
Forsberg U, Jonsson P, Stegmayr C, Jonsson F, Nilsson B, Nilsson Ekdahl K, Stegmayr B. A high blood level in the venous chamber and a wet-stored dialyzer help to reduce exposure for microemboli during hemodialysis. Hemodial Int 2013; 17:612-7. [PMID: 23627921 DOI: 10.1111/hdi.12052] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
During hemodialysis (HD), microemboli develop in the blood circuit of the apparatus. These microemboli can pass through the venous chamber and enter into the patient's circulation. The aim of this study was to investigate whether it is possible to reduce the risk for exposure of microemboli by altering of the treatment mode. Twenty patients on chronic HD were randomized to a prospective cross-over study of three modes of HD: (a) a dry-stored dialyzer (F8HPS, Fresenius, steam sterilized) with a low blood level in the venous chamber (DL), (b) the same dialyzer as above, but with a high level in the venous chamber (DH), and (c) a wet-stored dialyzer (Rexeed, Asahi Kasei Medical, gamma sterilized) with a high blood level (WH). Microemboli measurements were obtained in a continuous fashion during 180 minutes of HD for all settings. A greater number of microemboli were detected during dialysis with the setting DL vs. WH (odds ratio [OR] 4.07, 95% confidence interval [CI] 4.03-4.11, P<0.0001) and DH vs. WH (OR 1.18, 95% CI 1.17-1.19, P<0.0001) and less for DH vs. DL (OR 0.290, 95% CI 0.288-0.293, P<0.0001). These data indicate that emboli exposure was least when using WH, greater with DH, and most with DL. This study shows that using a high blood level in the venous chamber and wet-stored dialyzers may reduce the number of microemboli.
Collapse
Affiliation(s)
- Ulf Forsberg
- Department of Public Health and Clinical Medicine, Division of Medicine, Umeå University, Umeå, Sweden; Department of Internal Medicine, Skellefteå County Hospital, Skellefteå, Sweden
| | | | | | | | | | | | | |
Collapse
|
8
|
Kim JC, Cruz D, Garzotto F, Kaushik M, Teixeria C, Baldwin M, Baldwin I, Nalesso F, Kim JH, Kang E, Kim HC, Ronco C. Effects of dialysate flow configurations in continuous renal replacement therapy on solute removal: computational modeling. Blood Purif 2013; 35:106-11. [PMID: 23343554 DOI: 10.1159/000346093] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND/AIMS Continuous renal replacement therapy (CRRT) is commonly used for critically ill patients with acute kidney injury. During treatment, a slow dialysate flow rate can be applied to enhance diffusive solute removal. However, due to the lack of the rationale of the dialysate flow configuration (countercurrent or concurrent to blood flow), in clinical practice, the connection settings of a hemodiafilter are done depending on nurse preference or at random. METHODS In this study, we investigated the effects of flow configurations in a hemodiafilter during continuous venovenous hemodialysis on solute removal and fluid transport using computational fluid dynamic modeling. We solved the momentum equation coupling solute transport to predict quantitative diffusion and convection phenomena in a simplified hemodiafilter model. RESULTS Computational modeling results showed superior solute removal (clearance of urea: 67.8 vs. 45.1 ml/min) and convection (filtration volume: 29.0 vs. 25.7 ml/min) performances for the countercurrent flow configuration. Countercurrent flow configuration enhances convection and diffusion compared to concurrent flow configuration by increasing filtration volume and equilibrium concentration in the proximal part of a hemodiafilter and backfiltration of pure dialysate in the distal part. In clinical practice, the countercurrent dialysate flow configuration of a hemodiafilter could increase solute removal in CRRT. Nevertheless, while this configuration may become mandatory for high-efficiency treatments, the impact of differences in solute removal observed in slow continuous therapies may be less important. Under these circumstances, if continuous therapies are prescribed, some of the advantages of the concurrent configuration in terms of simpler circuit layout and simpler machine design may overcome the advantages in terms of solute clearance. CONCLUSION Different dialysate flow configurations influence solute clearance and change major solute removal mechanisms in the proximal and distal parts of a hemodiafilter. Advantages of each configuration should be balanced against the overall performance of the treatment and its simplicity in terms of treatment delivery and circuit handling procedures.
Collapse
Affiliation(s)
- Jeong Chul Kim
- Department of Nephrology, Dialysis and Transplantation, San Bortolo Hospital, Vicenza, Italy
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Forsberg U, Jonsson P, Stegmayr C, Stegmayr B. A high blood level in the air trap reduces microemboli during hemodialysis. Artif Organs 2012; 36:525-9. [PMID: 22360799 DOI: 10.1111/j.1525-1594.2011.01415.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Previous studies have demonstrated the presence of air microemboli in the dialysis circuit and in the venous circulation of the patients during hemodialysis. In vitro studies indicate that a high blood level in the venous air trap reduces the extent of microbubble formation. The purpose of this study was to examine whether air microbubbles can be detected in the patient's access and if so, whether the degree of microbubble formation can be altered by changing the blood level in the venous air trap. This was a randomized, double-blinded, interventional study of 20 chronic hemodialysis patients. The patients were assigned to hemodialysis with either an elevated or a low blood level in the air trap. The investigator and the patient were blinded to the settings. The numbers of microbubbles were measured at the site of the arteriovenous (AV) access for 2 min with the aid of an ultrasonic Doppler device. The blood level in the air trap was then altered to the opposite setting and a new measurement was carried out after an equilibration period of 30 min. Median (range) for the number of microbubbles measured with the high air trap level and the low air trap level in AV access was 2.5 (0-80) compared with 17.5 (0-77), respectively (P = 0.044). The degree of microbubble formation in hemodialysis patients with AV access was reduced significantly if the blood level in the air trap was kept high. The exposure of potentially harmful air microbubbles was thereby significantly reduced. This measure can be performed with no additional healthcare cost.
Collapse
Affiliation(s)
- Ulf Forsberg
- Department of Internal Medicine, Skellefteå County Hospital, Skellefteå Institute of General Health and Medicine, Department of Medicine, Norrland University Hospital Institute of Technology, University of Umeå Department of Nephrology, Norrland University Hospital, Umeå, Sweden
| | | | | | | |
Collapse
|
10
|
Brunet P, Simon N, Roubicek C, Papa K, Berland Y, Bruguerolle B. [Manufacturing waste of hemodialyzers decreases oxidative phosphorylation of mitochondria isolated from rats]. Nephrol Ther 2010; 6:576-80. [PMID: 20598955 DOI: 10.1016/j.nephro.2010.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2010] [Revised: 05/19/2010] [Accepted: 05/20/2010] [Indexed: 10/19/2022]
Abstract
INTRODUCTION The persistence of manufacturing waste in hemodialysers is a neglected aspect of lack of hemodialysis biocompatibility. The effect of waste was tested on mitochondria isolated from rat liver. MATERIAL AND METHODS After throwing the first two liters of the rinse solution of hemodialysers, the third liter is lyophilized. The waste is placed in the presence of mitochondria. The parameter V3 is the synthesis of ATP, the respiratory control (RC) is the ability to activate phosphorylation in the presence of ADP, ADP/O is the ratio of ADP used on oxygen consumption. The study was conducted on two hemodialyzers sterilized with gamma rays (Tricea and APS) and one hemodialyzer sterilized with flowing steam (FX60). RESULTS The respiratory parameters in the presence of waste are expressed as percentage of values obtained in the presence of control (sterile water). The respective values with Tricea, APS and the FX are for V3: 67±14, 79±10, and 81±8% (T vs A p=0.02; T vs F p=0.01; A vs F p=0.68) ; for CR : 44±6, 63±7, and 74±9% (T vs A p<0.001; T vs X p<0.001; A vs F p=0.004) ; for ADP/O : 75±11, 90±19, 91±11% (T vs A p=0.16; T vs F p=0.01; A vs F p=0.68). The dose-response curves confirm the differences concerning V3 and RC but not concerning ADP/O. CONCLUSION The hemodialyzers contain waste which has toxic effects on isolated mitochondria. This waste impairs the oxidative phosphorylation. The fact that this waste is still present in the dialyzers despite rinsing with two liters should alert users about the importance of extensive rinsing and manufacturers about the importance of effective procedures in order to eliminate manufacturing waste.
Collapse
Affiliation(s)
- Philippe Brunet
- Centre de néphrologie et transplantation rénale, hôpital de la Conception, université de la Méditerranée Aix-Marseille-2, Assistance publique-Hôpitaux de Marseille, 147, boulevard Baille, 13005 Marseille, France.
| | | | | | | | | | | |
Collapse
|
11
|
Forsberg U, Jonsson P, Stegmayr C, Stegmayr B. Microemboli, developed during haemodialysis, pass the lung barrier and may cause ischaemic lesions in organs such as the brain. Nephrol Dial Transplant 2010; 25:2691-5. [PMID: 20305135 DOI: 10.1093/ndt/gfq116] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Chronic haemodialysis (HD) may relieve some medical problems of terminal uraemia, but the life expectancy of patients is still significantly shortened, and there is a greatly increased morbidity. This includes pulmonary morbidity and chronic central nervous system (CNS) abnormalities. Previous studies have shown that a considerable amount of air microbubbles emanate within the blood lines of the dialysis device and pass the air detector without sounding an alarm. The aim of this study was to investigate whether microemboli can pass to the patient and whether they could be detected in the carotid artery. METHODS A total of 54 patients on chronic HD (16 with central dialysis catheter) were investigated with an ultrasound detector (Hatteland, Røyken, Norway) for the presence of microemboli at the arteriovenous (AV) fistula/graft and at the common carotid artery before and during HD. Measurements were taken for 2 and 5 min, respectively. Non-parametric paired statistics were used (Wilcoxon). RESULTS The median number (range) and mean +/- SD of microembolic signals detected at the AV access site before commencing dialysis and during HD were 0 (0-3) and 0.2+/- 0.5 versus 4 (0-85) and 13.5 +/- 20 (P = 0.000); at the carotid artery, 1 (0-14) and 1.7 +/- 2.9 versus 2 (0-36) and 3.5 +/- 5.8 (P = 0.008). CONCLUSIONS The infused and returning fluid from HD devices contains air microbubbles that enter the patient without triggering any alarms. These small emboli pass the lung and may cause ischaemic lesions in organs supported by the arterial circuit, such as the brain.
Collapse
Affiliation(s)
- Ulf Forsberg
- Medicin-Geriatriska Kliniken, Skelleftea lasarett, Lasarettsvagen 29, Skelleftea, Sweden.
| | | | | | | |
Collapse
|