1
|
Valbonesi M, Frisoni R, Florio G, Ferrari M. Intraoperative Blood Salvage: A New Artificial Organ? Int J Artif Organs 2018. [DOI: 10.1177/039139889501800305] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Optimal blood supply is critical to modern medical practice. Among the different possibilities of improving the quality and safety of blood, it is generally felt that autologous donation has played an important role and has contributed to changing transfusional practices, mainly since the appearance of HIV and HCV on the blood transfusion scene. At the San Martino Hospital Immunohematology Service, the autotransfusion era began in 1985. Autologous predeposit donation was the first to be introduced, followed by intentional perioperative hemodilution, intraoperative blood salvage with DFC apparatuses and lastly post-operative blood salvage. From about 200 autologous donations in 1985 we reached 5,372 in 1993 and more than 6,000 autologus donations are expected for 1994. Only 189 intraoperative blood salvages, were carried out in 1986, 593 in 1989, 1,207 in 1993 and more than 1,500 blood salvage sessions are anticipated for 1994. In the meantime, the total number of homologous RBC units employed in the Hospital dropped from 45,000 in 1985 to 18,000 in 1994, with the Onco-hematological Divisions using approximately 10,000 units of packed RBC.
Collapse
Affiliation(s)
- M. Valbonesi
- Immunohematology Services, San Martino University Hospital, Genova - Italy
| | - R. Frisoni
- Immunohematology Services, San Martino University Hospital, Genova - Italy
| | - G. Florio
- Immunohematology Services, San Martino University Hospital, Genova - Italy
| | - M. Ferrari
- Immunohematology Services, San Martino University Hospital, Genova - Italy
| |
Collapse
|
2
|
The Fresenius Continuous Autotransfusion System (CATS): Preliminary Studies and Application. Int J Artif Organs 2018. [DOI: 10.1177/039139889601900709] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A new CFC apparatus for intraoperative blood salvage (CATS) has been introduced by Fresenius and submitted to preliminary evaluation at our hemapheresis unit. The volume of shed blood submitted to washing was 1714 ± 496 with a hematocrit of 19% and the volume of PRBC ready for transfusion 297.9 ml with hematocrit of 64.3%. Elimination of contaminant activated platelets and WBC was 92% and 74% respectively. Elimination of contaminants such as protein, free hemoglobin, LDH and K ions was always over 95%. Regular application of CATS is warrented after our study.
Collapse
|