Roy A, Bennett A, Pruitt L. Feasibility of using diamond-like carbon films in total joint replacements: a review. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2024; 35:47. [PMID: 39136884 PMCID: PMC11322245 DOI: 10.1007/s10856-024-06814-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Accepted: 07/16/2024] [Indexed: 08/16/2024]
Abstract
Diamond-like Carbon (DLC) has been used as a coating material of choice for a variety of technological applications owing to its favorable bio-tribo-thermo-mechanical characteristics. Here, the possibility of bringing DLC into orthopedic joint implants is examined. With ever increasing number of patients suffering from osteoarthritis as well as with the ingress of the osteoarthritic joints' malaise into younger and more active demographics, there is a pressing need to augment the performance and integrity of conventional total joint replacements (TJRs). Contemporary joint replacement devices use metal-on-polymer articulations to restore function to worn, damaged or diseased cartilage. The wear of polymeric components has been addressed using crosslinking and antioxidants; however, in the context of the metallic components, complications pertaining to corrosion and metal ion release inside the body still persist. Through this review article, we explore the use of DLC coatings on metallic bearing surfaces and elucidate why this technology might be a viable solution for ongoing electrochemical challenges in orthopedics. The different characteristics of DLC coatings and their feasibility in TJRs are examined through assessment of tribo-material characterization methods. A holistic characterization of the coating-substrate interface and the wear performance of such systems are discussed. As with all biomaterials used in TJRs, we need mindful consideration of potential in-vivo challenges. We present a few caveats for DLC coatings including delamination, hydrophobicity, and other conflicting as well as outdating findings in the literature. We recommend prudently exploring DLC films as potential coatings on metallic TJR components to solve the problems pertaining to wear, metal ion release, and corrosion. Ultimately, we advise bringing DLC into clinical use only after addressing all challenges and concerns outlined in this article.
Collapse
Affiliation(s)
- Anurag Roy
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA.
| | - Annette Bennett
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Lisa Pruitt
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| |
Collapse
|
2
|
熊 守, 屈 亚, 任 佳, 张 静, 李 辉, 陈 瑱. [Effect of prosthetic joint line installation height errors on insert wear in unicompartmental knee arthroplasty]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2023; 40:1192-1199. [PMID: 38151943 PMCID: PMC10753317 DOI: 10.7507/1001-5515.202307051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 11/02/2023] [Indexed: 12/29/2023]
Abstract
The clinical performance and failure issues are significantly influenced by prosthetic malposition in unicompartmental knee arthroplasty (UKA). Uncertainty exists about the impact of the prosthetic joint line height in UKA on tibial insert wear. In this study, we combined the UKA musculoskeletal multibody dynamics model, finite element model and wear model to investigate the effects of seven joint line height cases of fixed UKA implant on postoperative insert contact mechanics, cumulative sliding distance, linear wear depth and volumetric wear. As the elevation of the joint line height in UKA, the medial contact force and the joint anterior-posterior translation during swing phase were increased, and further the maximum von Mises stress, contact stress, linear wear depth, cumulative sliding distance, and the volumetric wear also were increased. Furthermore, the wear area of the insert gradually shifted from the middle region to the rear. Compared to 0 mm joint line height, the maximum linear wear depth and volumetric wear were decreased by 7.9% and 6.8% at -2 mm joint line height, and by 23.7% and 20.6% at -6 mm joint line height, the maximum linear wear depth and volumetric wear increased by 10.7% and 5.9% at +2 mm joint line height, and by 24.1% and 35.7% at +6 mm joint line height, respectively. UKA prosthetic joint line installation errors can significantly affect the wear life of the polyethylene inserted articular surfaces. Therefore, it is conservatively recommended that clinicians limit intraoperative UKA joint line height errors to -2-+2 mm.
Collapse
Affiliation(s)
- 守林 熊
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang’an University, Xi’an 710064, P. R. China
| | - 亚飞 屈
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang’an University, Xi’an 710064, P. R. China
| | - 佳轩 任
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang’an University, Xi’an 710064, P. R. China
| | - 静 张
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang’an University, Xi’an 710064, P. R. China
| | - 辉 李
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang’an University, Xi’an 710064, P. R. China
| | - 瑱贤 陈
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang’an University, Xi’an 710064, P. R. China
| |
Collapse
|
3
|
Dreyer MJ, Trepczynski A, Hosseini Nasab SH, Kutzner I, Schütz P, Weisse B, Dymke J, Postolka B, Moewis P, Bergmann G, Duda GN, Taylor WR, Damm P, Smith CR. Standardized Tibio-Femoral Implant Loads and Kinematics. J Biomech 2022; 141:111171. [DOI: 10.1016/j.jbiomech.2022.111171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 04/10/2022] [Accepted: 05/26/2022] [Indexed: 10/18/2022]
|
4
|
Abdelgaied A, Fisher J, Jennings L. Understanding the differences in wear testing method standards for total knee replacement. J Mech Behav Biomed Mater 2022; 132:105258. [DOI: 10.1016/j.jmbbm.2022.105258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 03/04/2022] [Accepted: 04/29/2022] [Indexed: 10/18/2022]
|
5
|
Mell SP, Wimmer MA, Lundberg HJ. Sensitivity of total knee replacement wear to variability in motion and load input: A parametric finite element analysis study. J Orthop Res 2020; 38:1538-1549. [PMID: 32458460 PMCID: PMC9595431 DOI: 10.1002/jor.24755] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Revised: 03/30/2020] [Accepted: 05/25/2020] [Indexed: 02/04/2023]
Abstract
Polyethylene wear remains a contributor to long term failure in total knee replacements (TKRs). Advances in materials have improved polyethylene wear rates, therefore further wear reductions require a better understanding of patient-specific factors that lead to wear. Variability of gait within patients is considerable and could lead to significant variability in wear rates that cannot be predicted by standard testing methods. An in-silico study was performed to investigate the influence of gait variability on TKR polyethylene wear. Nine characteristic peaks within the load and motion profiles used for TKR wear testing were varied 75% to 125% from baseline (ISO-14243-3:2014) to generate 310 unique waveforms. Wear was calculated for 1-million cycles using a finite element TKR wear model. From the results, a surrogate model was developed using multiple linear regression, and used to predict how wear changes due to dispersion of motion and force peaks within a) ±5%, the maximum allowable input tolerance of ISO, and b) ±25%, more reflective of patient gait inter-variability. The range of wear within the ±5% tolerance was 0.65 mm3 /million cycles and was 3.24 mm3 /million cycles within the ±25% variability more in line with the dispersion observed within patients. Although no one kinematic or kinetic peak dominated variability in TKR volumetric wear, variability within flexion/extension peaks were the largest contributor to wear rate variability. Interaction between the peaks of different waveforms was also important. This study, and future studies incorporating patient-specific data, could help to explain the connection between patient-specific gait factors and wear rates.
Collapse
|
6
|
Enhanced In-Silico Polyethylene Wear Simulation of Total Knee Replacements During Daily Activities. Ann Biomed Eng 2020; 49:322-333. [PMID: 32607843 DOI: 10.1007/s10439-020-02555-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 06/19/2020] [Indexed: 10/24/2022]
Abstract
A computational wear simulator is an efficient tool for evaluating the wear of artificial knee joints. The classical Archard's wear law-based simulator has questionable accuracy and is focused on walking. In this study, an in silico polyethylene wear simulation of total knee replacements was developed considering the various highly demanding daily activities. A good predicted accuracy (error = 8.1%) was found through comparison of the experimental results. A relatively larger averaged wear loss was found under the loading condition (1.53 mg/mc) of daily activities compared with the walking condition (1.32 mg/mc). The squatting movement (2.57 mg/mc) produces the highest overall wear rate. In addition, a relatively larger amount of wear was found on the medial side knee prosthesis than that on the lateral side. The enhanced in silico polyethylene wear simulator provides an accurate and comprehensive tool for wear prediction in preclinical wear testing.
Collapse
|
7
|
Burchardt A, Abicht C, Sander O. An efficient and robust simulator for wear of total knee replacements. Proc Inst Mech Eng H 2020; 234:921-930. [PMID: 32579092 DOI: 10.1177/0954411920933022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Wear on total knee replacements is an important criterion for their performance characteristics. Numerical simulations of such wear have seen increasing attention over the last years. They have the potential to be much faster and less expensive than the in vitro tests in use today. While it is unlikely that in silico tests will replace actual physical tests in the foreseeable future, a judicious combination of both approaches can help making both implant design and pre-clinical testing quicker and more cost-effective. The challenge today for the design of simulation methods is to obtain results that convey quantitative information and to do so quickly and reliably. This involves the choice of mathematical models as well as the numerical tools used to solve them. The correctness of the choice can only be validated by comparing with experimental results. In this article, we present finite element simulations of the wear in total knee replacements during the gait cycle standardized in the ISO 14243-1 document, used for compliance testing in several countries. As the ISO 14243-1 standard is precisely defined and publicly available, it can serve as an excellent benchmark for comparison of wear simulation methods. We use comparatively simple wear and material models, but we solve them using a new wear algorithm that combines extrapolation of the geometry changes with a contact algorithm based on nonsmooth multigrid ideas. The contact algorithm works without Lagrange multipliers and penalty parameters, achieving unparalleled stability and efficiency. We compare our simulation results with the experimental data from physical tests using two different actual total knee replacements. Even though the model is simple, we can predict the total mass loss due to wear after 5-million gait cycles, and we observe a good match between the wear patterns seen in experiments and our simulation results. When compared with a state-of-the-art penalty-based solver for the same model, we measure a roughly fivefold increase of execution speed.
Collapse
Affiliation(s)
- Ansgar Burchardt
- Institut für Numerische Mathematik, Technische Universität Dresden, Dresden, Germany
| | | | - Oliver Sander
- Institut für Numerische Mathematik, Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
8
|
Hussin MS, Fernandez J, Ramezani M, Kumar P, Kelly PA. Analytical and computational sliding wear prediction in a novel knee implant: a case study. Comput Methods Biomech Biomed Engin 2020; 23:143-154. [PMID: 31928215 DOI: 10.1080/10255842.2019.1709118] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Osteoarthritis (OA) is a commonly occurring cartilage degenerative disease. The end stage treatment is Total Knee Arthroplasty (TKA), which can be costly in terms of initial surgery, but also in terms of revision knee arthroplasty, which is quite often required. A novel conceptual knee implant has been proposed to function as a reducer of stress across the joint surface, to extend the period of time before TKA becomes necessary. The objective of this paper is to develop a computational model which can be used to assess the wear arising at the implant articulating surfaces. Experimental wear coefficients were determined from physical testing, the results of which were verified using a semi-analytical model. Experimental results were incorporated into an anatomically correct computational model of the knee and implant. The wear-rate predicted for the implant was 27.74 mm3 per million cycles (MC) and the wear depth predicted was 1.085 mm/MC. Whereas the wear-rate is comparable to that seen in conventional knee implants, the wear depth is significantly higher than for conventional knee prostheses, and indicates that, in order to be viable, wear-rates should be reduced in some way, perhaps by using low-wear polymers.
Collapse
Affiliation(s)
- Mohd Sabri Hussin
- Department of Engineering Science, University of Auckland, Auckland, New Zealand.,School of Manufacturing Engineering, Universiti Malaysia Perlis, Perlis, Malaysia
| | - Justin Fernandez
- Department of Engineering Science, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Maziar Ramezani
- Department of Mechanical Engineering, Auckland University of Technology, Auckland, New Zealand
| | | | - Piaras A Kelly
- Department of Engineering Science, University of Auckland, Auckland, New Zealand
| |
Collapse
|
9
|
Mell SP, Fullam S, Wimmer MA, Lundberg HJ. Computational Parametric Studies for Preclinical Evaluation of Total Knee Replacements. LECTURE NOTES IN COMPUTATIONAL VISION AND BIOMECHANICS 2020. [DOI: 10.1007/978-3-030-43195-2_6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
10
|
Johnston H, Abdelgaied A, Pandit H, Fisher J, Jennings LM. The effect of surgical alignment and soft tissue conditions on the kinematics and wear of a fixed bearing total knee replacement. J Mech Behav Biomed Mater 2019; 100:103386. [PMID: 31408775 DOI: 10.1016/j.jmbbm.2019.103386] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 07/18/2019] [Accepted: 08/02/2019] [Indexed: 11/19/2022]
Abstract
As life expectancy and activity levels of patients increase so does the demand on total knee replacements (TKRs). Abnormal mechanics and wear of TKRs can lead to implant loosening and revision. Component alignment after surgery varies due to the presurgical alignment, the accuracy of the surgical instrumentation and due to patient factors, such as the soft tissue balance. This study experimentally investigated the effect of variation in component alignment and the soft tissue conditions on the kinematics and wear of a fixed bearing TKR. DePuy Sigma fixed bearing TKRs with moderately cross-linked UHMWPE were used. Different alignment conditions were simulated in the coronal, sagittal and transverse planes in an ISO force-controlled simulation system. Three different soft tissue conditions were simulated using virtual springs to represent a stiff knee, a preserved PCL and a resected PCL. Four different alignment conditions were studied; ideal alignment, 4° tibial and femoral varus joint line, 14° rotational mismatch and 10° posterior tibial slope. The varus joint line alignment resulted in similar kinematics and lower wear rate compared to ideal alignment. The rotational mismatch alignment resulted in significantly higher tibial rotation and abduction-adduction as well as a significantly higher wear rate than ideal alignment. The posterior tibial slope alignment resulted in significantly higher wear than the ideal alignment and dislocated under the lower tension soft tissue conditions. Component alignment and the soft tissue conditions had a significant effect on the kinematics and wear of the TKR investigated in this study. The surgical alignment of the TKR is an important factor in the clinical outcome of the joint as factors such as increased tibial rotation can lead to anterior knee pain and instability and increased wear can lead to aseptic loosening and early failure resulting in revision.
Collapse
Affiliation(s)
- Helena Johnston
- Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| | | | - Hemant Pandit
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, Faculty of Medicine and Health, University of Leeds, Leeds, UK
| | - John Fisher
- Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| | - Louise M Jennings
- Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK.
| |
Collapse
|
11
|
Mell SP, Wimmer MA, Lundberg HJ. The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3. J Biomech 2019; 88:104-112. [PMID: 30940359 DOI: 10.1016/j.jbiomech.2019.03.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 03/08/2019] [Accepted: 03/18/2019] [Indexed: 01/16/2023]
Abstract
A leading cause of long-term failure of total knee replacements (TKRs) is osteolysis caused by polyethylene wear particles. The current gold standard for preclinical wear testing of TKRs is mechanical knee simulators. The definition of the femoral center of flexion-extension rotation (CoR) has been identified as one possible source of variability within TKR wear tests, since the femoral curvature varies from distal to posterior. The magnitude of the influence on wear due to changes in location of femoral CoR has not been investigated in depth. During this study, a computational framework utilizing finite element analysis for modelling wear of TKRs was developed and used to investigate the influence of the location of femoral CoR on TKR polyethylene wear during standardized displacement controlled testing (ISO 14243-3:2014). The study was carried out using a 40-point Latin Hypercube Design of Experiments approach. Volumetric wear was highly correlated to femoral CoR in both the superior/inferior and anterior/posterior directions, with a stronger relationship in the superior/inferior direction. In addition, wear scars showing linear penetration were examined, with large differences in simulations at the extreme ends of the sampling region. In this study, it was found that variations in the location of the femoral center of rotation can represent a large source of variability in the preclinical testing and evaluation of the wear performance of total knee replacements. This study represents the first attempt at quantifying the effect on wear of different femoral center of rotations across a large sampling space.
Collapse
|
12
|
Johnston H, Abdelgaied A, Pandit H, Fisher J, Jennings LM. Representing the effect of variation in soft tissue constraints in experimental simulation of total knee replacements. J Mech Behav Biomed Mater 2018; 87:87-94. [DOI: 10.1016/j.jmbbm.2018.07.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Revised: 07/04/2018] [Accepted: 07/05/2018] [Indexed: 11/25/2022]
|
13
|
Comparison of CMM and Micro-CT Volumetric Analysis of Polyethylene Tibial Knee Inserts in Total Knee Replacement. INT J POLYM SCI 2018. [DOI: 10.1155/2018/3601480] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Ultrahigh molecular weight polyethylene (UHMWPE) bearings are used widely in orthopaedic joint replacement as a prominent material for improving the longevity, which is dramatically influenced by wear of polyethylene. Polyethylene tibial knee components from knee simulators under two different input conditions were analyzed using CMM and Micro-CT measurement techniques for volumetric loss with gravimetric measurement as reference. Based on the coordinates and image slices obtained, the surface curve fitting and image digitization methodology were used for the creation of nominal “original” surface in the case of no prewear data provided. The comparison results indicate that gravimetric remains the gold standard and the CMM measurement took less time and had better precision, accuracy, and repeatability compared to Micro-CT measurement technique.
Collapse
|
14
|
Mell SP, Fullam S, Wimmer MA, Lundberg HJ. Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners. Proc Inst Mech Eng H 2018; 232:545-552. [PMID: 29658386 DOI: 10.1177/0954411918770700] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Current treatment for end-stage osteoarthritis is total knee replacement. Given that the number of total knee replacement surgeries is expected to approach 3.48 million by 2030, understanding long-term failure is important. One of the preclinical tests for total knee replacements is carried out using mechanical wear testing under generic walking conditions. Used for this purpose is the International Standards Organization's generic walking profile. Recently this standard was updated by reversing the direction of anterior/posterior translation and internal/external rotation. The effects of this change have not been investigated, and therefore, it is unknown if comparisons between wear tests utilizing the old and new version of the standard are valid. In this study, we used a finite element model along with a frictional energy-based wear model to compare the kinematic inputs, contact conditions, and wear from the older and newer versions of the ISO standard. Simulator-tested components were used to validate the computational model. We found that there were no visible similarities in the contact conditions between the old and new versions of the standard. The new version of the standard had a lower wear rate but covered a larger portion of the articular surface. Locations of wear also varied considerably. The results of the study suggest that major differences between the old and new standard exist, and therefore, historical wear results should be compared with caution to newly obtained results.
Collapse
Affiliation(s)
- Steven P Mell
- 1 Department of Orthopedic Surgery, Rush University, Chicago, IL, USA
| | - Spencer Fullam
- 1 Department of Orthopedic Surgery, Rush University, Chicago, IL, USA
| | - Markus A Wimmer
- 1 Department of Orthopedic Surgery, Rush University, Chicago, IL, USA
| | - Hannah J Lundberg
- 1 Department of Orthopedic Surgery, Rush University, Chicago, IL, USA
| |
Collapse
|
15
|
Abdelgaied A, Fisher J, Jennings LM. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements. J Mech Behav Biomed Mater 2017; 78:282-291. [PMID: 29195220 PMCID: PMC5776076 DOI: 10.1016/j.jmbbm.2017.11.022] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 11/10/2017] [Accepted: 11/13/2017] [Indexed: 12/02/2022]
Abstract
A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active patients (National_Joint_Registry, 2016). The current study has developed and validated a comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements (TKR). The input mechanical (elastic modulus and Poisson’s ratio) and wear parameters of the moderately cross-linked ultra-high molecular weight polyethylene (UHMWPE) bearing material were independently measured from experimental studies under realistic test conditions, similar to the loading conditions found in the total knee replacements. The wear predictions from the computational wear simulation were validated against the direct experimental wear measurements for size 3 Sigma curved total knee replacements (DePuy, UK) in an independent experimental wear simulation study under three different daily activities; walking, deep squat, and stairs ascending kinematic conditions. The measured compressive mechanical properties of the moderately cross-linked UHMWPE material were more than 20% lower than that reported in the literature under tensile test conditions. The pin-on-plate wear coefficient of moderately cross-linked UHMWPE was significantly dependant of the contact stress and the degree of cross-shear at the articulating surfaces. The computational wear predictions for the TKR from the current framework were consistent and in a good agreement with the independent full TKR experimental wear simulation measurements, with 0.94 coefficient of determination of the framework. In addition, the comprehensive combined experimental and computational framework was able to explain the complex experimental wear trends from the three different daily activities investigated. Therefore, such a framework can be adopted as a pre-clinical simulation approach to optimise different designs, materials, as well as patient’s specific total knee replacements for a range of activities.
Collapse
|
16
|
Abdelgaied A, Fisher J, Jennings LM. A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements. Proc Inst Mech Eng H 2017; 231:643-651. [PMID: 28661228 PMCID: PMC5495426 DOI: 10.1177/0954411917696519] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
More robust preclinical experimental wear simulation methods are required in order to simulate a wider range of activities, observed in different patient populations such as younger more active patients, as well as to fully meet and be capable of going well beyond the existing requirements of the relevant international standards. A new six-station electromechanically driven simulator (Simulation Solutions, UK) with five fully independently controlled axes of articulation for each station, capable of replicating deep knee bending as well as other adverse conditions, which can be operated in either force or displacement control with improved input kinematic following, has been developed to meet these requirements. This study investigated the wear of a fixed-bearing total knee replacement using this electromechanically driven fully independent knee simulator and compared it to previous data from a predominantly pneumatically controlled simulator in which each station was not fully independently controlled. In addition, the kinematic performance and the repeatability of the simulators have been investigated and compared to the international standard requirements. The wear rates from the electromechanical and pneumatic knee simulators were not significantly different, with wear rates of 2.6 ± 0.9 and 2.7 ± 0.9 mm3/million cycles (MC; mean ± 95% confidence interval, p = 0.99) and 5.4 ± 1.4 and 6.7 ± 1.5 mm3/MC (mean ± 95 confidence interval, p = 0.54) from the electromechanical and pneumatic simulators under intermediate levels (maximum 5 mm) and high levels (maximum 10 mm) of anterior-posterior displacements, respectively. However, the output kinematic profiles of the control system, which drive the motion of the simulator, followed the input kinematic profiles more closely on the electromechanical simulator than the pneumatic simulator. In addition, the electromechanical simulator was capable of following kinematic and loading input cycles within the tolerances of the international standard requirements (ISO 14243-3). The new-generation electromechanical knee simulator with fully independent control has the potential to be used for a much wider range of kinematic conditions, including high-flexion and other severe conditions, due to its improved capability and performance in comparison to the previously used pneumatic-controlled simulators.
Collapse
Affiliation(s)
| | - John Fisher
- Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| | - Louise M Jennings
- Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
17
|
Cowie RM, Briscoe A, Fisher J, Jennings LM. PEEK-OPTIMA ™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study. Proc Inst Mech Eng H 2016; 230:1008-1015. [PMID: 27637723 PMCID: PMC5256473 DOI: 10.1177/0954411916667410] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These preliminary findings showed that PEEK-OPTIMA™ gives promise as an alternative bearing material to cobalt chrome alloy in the femoral component of a total knee replacement with respect to wear performance.
Collapse
Affiliation(s)
- Raelene M Cowie
- 1 Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| | - Adam Briscoe
- 2 Invibio Ltd, Technology Centre, Hillhouse International, Thornton Cleveleys, UK
| | - John Fisher
- 1 Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| | - Louise M Jennings
- 1 Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK
| |
Collapse
|