1
|
Vignesh R, Sharma V, Basu B. Computational nodal displacement analysis of acetabulum fossa for injection molded cemented polyethylene acetabular liner. J Mech Behav Biomed Mater 2023; 147:106109. [PMID: 37742598 DOI: 10.1016/j.jmbbm.2023.106109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 09/05/2023] [Accepted: 09/05/2023] [Indexed: 09/26/2023]
Abstract
The acetabular liner (AL) is one of the key components that determine the functionality and durability of the total hip joint replacement (THR) device. The performance of Ultra high molecular weight polyethylene (UHMWPE)-based AL depends critically on the manufacturing route and its properties, which are evaluated pre-clinically using a host of experimental and computational analyses. The conventional manufacturing of an AL involves multiple stages, including extrusion/compression molding followed by machining, which is time/cost intensive and leads to material loss. In such a scenario, injection molding is a promising alternative, yet its feasbility remains unexplored for the manufacturing of AL for THA applications. Against this backdrop, the two-fold objectives of this work are to report our recent efforts to establish the efficacy of the injection molding of new generation UHMWPE biomaterial; HU (60 wt% HDPE- 40 wt% UHMWPE blend) for manufacturing AL prototype and to present the key biomechanical response analysis of this prototype, in silico. A range of manufacturing relevant material properties, as well as customized mold design to manufacture HU-based AL with external design features, are discussed. Such guidelines are particularly relevant to mold polymeric parts with a higher thickness (>8 mm). As part of the pre-clinical validation of AL with new design features, a less explored in silico approach to assess biomechanical micro-strain in the acetabulum fossa is presented, and the results are analysed in accordance with the mechanostat theory. The outcomes revealed that for a 100 kg subject weight, average micro-strain in the remodelling region was 1132, while it was determined as 723 for a 55 kg subject weight. Such results highlight the influence of subject weight on micro-strain generation and distribution in the acetabulum fossa. The von Mises stress in AL also increased with subject weight from 17 MPa in a subject weight of 55 kg to 28 MPa in a subject weight of 100 kg. Taken together, this work demonstrates the feasibility and competence of this new generation biomaterial in terms of implant manufacturing via injection molding with a clinically desired biomechanical response.
Collapse
Affiliation(s)
- R Vignesh
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore 560012, India; Centre of Excellence for Dental and Orthopedic Applications, Material Research Centre, Indian Institute of Science, Bangalore 560012, India
| | - Vidushi Sharma
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore 560012, India; Centre of Excellence for Dental and Orthopedic Applications, Material Research Centre, Indian Institute of Science, Bangalore 560012, India
| | - Bikramjit Basu
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore 560012, India; Centre of Excellence for Dental and Orthopedic Applications, Material Research Centre, Indian Institute of Science, Bangalore 560012, India; Centre for Biosystems Science and Engineering, Indian Institute of Science, Bangalore 560012, India.
| |
Collapse
|
2
|
Gupta A, Dutta A, Dutta K, Mukherjee K. Biomechanical influence of plate configurations on mandible subcondylar fracture fixation: a finite element study. Med Biol Eng Comput 2023; 61:2581-2591. [PMID: 37233860 DOI: 10.1007/s11517-023-02854-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 05/17/2023] [Indexed: 05/27/2023]
Abstract
Mandible subcondylar fractures have very high complication rate, yet there is no consensus on suitable plate design for optimal patient outcomes. Our study is aimed at comparing single mini, trapezoid, lambda, strut and double mini plates. A finite-element (FE) model of intact mandible was developed based on healthy CT-scan data, which was further virtually osteotomized and fixated with plates. The cortical and cancellous bones were assigned region-specific orthotropic and heterogenous isotropic material properties respectively. The models were subjected to six load cases representing the mastication cycle. Under opposite lateralities, the tensile and compressive mandibular strain distributions were found as the opposite, with tensile strains at the posterior border under ipsilateral molar clenching (RMOL) resulting in lesser mandibular strain in reconstructed mandible with single mini plate under RMOL but highest mandibular strain under the contralateral molar clenching (LMOL). Owing to the reduced mandibular strains under LMOL than RMOL, the contralateral chewing is preferred during the immediate post-surgery period for patients. Under LMOL, the peak von Mises stresses in the plate decreased with increase in the number of screws. Furthermore, the presence of two arms in double mini and trapezoid plates seems beneficial to neutralise the tensile and compressive strains across load cases.
Collapse
Affiliation(s)
- Anoushka Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India
| | - Abir Dutta
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India
- Department of Ortho and MSK Science, University College London, London, UK
| | - Kaushik Dutta
- Department of Oral Medicine and Radiology, Guru Nanak Institute of Dental Sciences and Research, Kolkata, India
| | - Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India.
| |
Collapse
|
3
|
Saviour CM, Gupta S. Design of a functionally graded porous uncemented acetabular component: Influence of polar gradation. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023:e3709. [PMID: 37089063 DOI: 10.1002/cnm.3709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 02/14/2023] [Accepted: 04/05/2023] [Indexed: 05/03/2023]
Abstract
The functionally graded porous metal-backed (FGPMB) acetabular component has the potential to minimize strain-shielding induced bone resorption, caused by stiffness mismatch of implant and host bone. This study is aimed at a novel design of FGPMB acetabular component, which is based on numerical investigations of the mechanical behavior of acetabular components with regard to common failure scenarios, considering various daily activities and implant-bone interface conditions. Both radial and polar functional gradations were implemented, and the effects of the polar gradation exponent on the failure criteria were evaluated. The relationships between porosity and orthotropic mechanical properties of a tetrahedron-based unit cell were obtained using a numerical homogenization method. Strain-shielding in cancellous bone was relatively lesser for the FGPMB than solid metal-backing. Few nodes around the rim were susceptible to implant-bone interfacial debonding, irrespective of the polar gradation exponent. Although the most favorable bone remodeling predictions were obtained for a polar gradation exponent of 0.1, a sudden change in the porosity was observed near the rim of FGPMB. Bone remodeling patterns were similar for polar gradation exponent of 5.0 and solid metal-backing. Moreover, the volumetric wear was maximum and minimum for polar gradation exponents of 0.1 and 5, respectively. Furthermore, the micromotions of different polar gradation exponents were within a range (20-40 μm) that might facilitate bone ingrowth. Considering common failure mechanisms, the FGPMB having polar gradation exponents in the range of 0.1-0.5 appeared to be a viable alternative to the solid acetabular component, within which a gradation exponent of 0.25 seemed the most appropriate design parameter.
Collapse
Affiliation(s)
- Ceby Mullakkara Saviour
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| |
Collapse
|
4
|
Dutta A, Mukherjee K, Seesala VS, Dutta K, Paul RR, Dhara S, Gupta S. Comparative evaluation of a patient-specific customised plate designs and screws for partial mandibular reconstruction. Med Eng Phys 2023; 111:103941. [PMID: 36792242 DOI: 10.1016/j.medengphy.2022.103941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 09/27/2022] [Accepted: 12/06/2022] [Indexed: 12/13/2022]
Abstract
Mandibles with odontogenic tumors are often partially reconstructed with a metallic bone graft analogue with dental roots, crowns, along with a customized plate fixed with monocortical or bicortical screws, following resection of the tumor. In this study, two different designs of patient specific customized Ti reconstruction plates, solid and plate with holes, were considered. Fixation through both bicortical and monocortical screw types were investigated. FE models of the reconstructed mandibles were developed to analyse the influence of the plate-screw type combination on the load transfer across the mandibles under a mastication cycle. The effective homogenized orthotropic material properties of the lattice structures with 0.6 mm fibre diameter with 0.5 mm inter-fibre space were assigned to material properties for the bone graft analogue. The study shows that the combination of plate and screw types influences the state of stresses in the reconstructed mandible. Based on the results of this patient specific study, following resection of the tumor, either solid Ti plate with bicortical screws or Ti plate with holes along with monocortical screws may be used for partial mandibulectomy. It should also be noted that stresses in none of the plates or screws exceeded the yield limit for Ti under the mastication cycle indicating that the components are safe for mandibular reconstruction. However, the choice of this combination of reconstruction plates and screws is dependant on the condition and severity of the tumor in the diseased mandible.
Collapse
Affiliation(s)
- Abir Dutta
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India
| | - Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India; Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India.
| | - Venkata Sundeep Seesala
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India
| | - Kaushik Dutta
- Gurunanak Institute of Dental Science and Research, Department of Oral and Maxillofacial Pathology, Kolkata, West Bengal 700 114, India
| | - Ranjan Rashmi Paul
- Gurunanak Institute of Dental Science and Research, Department of Oral and Maxillofacial Pathology, Kolkata, West Bengal 700 114, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India
| |
Collapse
|
5
|
Xiong B, Yang P, Lin T, Xu J, Xie Y, Guo Y, Liu C, Zhou QI, Lai Q, He W, Wei Q, Zhang Q. Changes in hip joint contact stress during a gait cycle based on the individualized modeling method of "gait-musculoskeletal system-finite element". J Orthop Surg Res 2022; 17:267. [PMID: 35568957 PMCID: PMC9107226 DOI: 10.1186/s13018-022-03094-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Accepted: 03/20/2022] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE To construct a comprehensive simulation method of "gait-musculoskeletal system (MS)-finite element (FE)" for analysis of hip joint dynamics characteristics and the changes in the contact stress in the hip throughout a gait cycle. METHODS Two healthy volunteers (male and female) were recruited. The 3D gait trajectories during normal walking and the CT images including the hip and femur of the volunteers were obtained. CT imaging data in the DICOM format were extracted for subjected 3D hip joint reconstruction. The reconstructed 3D model files were used to realize the subject-specific registration of the pelvis and thigh segment of general musculoskeletal model. The captured marker trajectory data were used to drive subject-specific musculoskeletal model to complete inverse dynamic analysis. Results of inverse dynamic analysis were exported and applied as boundary and load settings of the hip joint finite element in ABAQUS. Finally, the finite element analysis (FEA) was performed to analyze contact stress of hip joint during a gait cycle of left foot. RESULTS In the inverse dynamic analysis, the dynamic changes of the main hip-femoral muscle force with respect to each phase of a single gait cycle were plotted. The hip joint reaction force reached a maximum value of 2.9%BW (body weight) and appeared at the end of the terminal stance phase. Twin peaks appeared at the initial contact phase and the end of the terminal stance phase, respectively. FEA showed the temporal changes in contact stress in the acetabulum. In the visual stress cloud chart, the acetabular contact stress was mainly distributed in the dome of the acetabulum and in the anterolateral area at the top of the femoral head during a single gait cycle. The acetabular contact area was between 293.8 and 998.4 mm2, and the maximum contact area appear at the mid-stance phase or the loading response phase of gait. The maximum contact stress of the acetabulum reached 6.91 MPa for the model 1 and 6.92 MPa for the model 2 at the terminal stance phase. CONCLUSIONS The "Gait-MS-FE" technology is integrated to construct a comprehensive simulation framework. Based on human gait trajectories and their CT images, individualized simulation modeling can be achieved. Subject-specific gait in combination with an inverse dynamic analysis of the MS provides pre-processing parameters for FE simulation for more accurate biomechanical analysis of hip joint.
Collapse
Affiliation(s)
- Binglang Xiong
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,The Lab of Orthopaedics of Chinese Medicine of Lingnan Medical Research Center, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,Department of Joint Orthopaedic, the First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China
| | - Peng Yang
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,The Lab of Orthopaedics of Chinese Medicine of Lingnan Medical Research Center, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,Department of Joint Orthopaedic, the First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,Second People's Hospital of Shenzhen, Shenzhen, 518000, Guangdong, China
| | - Tianye Lin
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,The Lab of Orthopaedics of Chinese Medicine of Lingnan Medical Research Center, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,Department of Joint Orthopaedic, the First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China
| | - Jingli Xu
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,The Lab of Orthopaedics of Chinese Medicine of Lingnan Medical Research Center, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,Department of Joint Orthopaedic, the First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China
| | - Yong Xie
- Guangzhou University, Guangzhou, 510006, Guangdong, China
| | - Yongliang Guo
- Brain Hospital Affiliated to Jinan University, Guangzhou, 510510, Guangdong, China
| | - Churong Liu
- Brain Hospital Affiliated to Jinan University, Guangzhou, 510510, Guangdong, China
| | - QIzhao Zhou
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,The Lab of Orthopaedics of Chinese Medicine of Lingnan Medical Research Center, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,Department of Joint Orthopaedic, the First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China
| | - Qizhong Lai
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,The Lab of Orthopaedics of Chinese Medicine of Lingnan Medical Research Center, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China.,Department of Joint Orthopaedic, the First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510405, Guangdong, China
| | - Wei He
- The Third Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510240, Guangdong, China.
| | - Qiushi Wei
- The Third Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510240, Guangdong, China.
| | - Qingwen Zhang
- The Third Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, 510240, Guangdong, China.
| |
Collapse
|
6
|
Mathai B, Dhara S, Gupta S. Bone remodelling in implanted proximal femur using topology optimization and parameterized cellular model. J Mech Behav Biomed Mater 2021; 125:104903. [PMID: 34717117 DOI: 10.1016/j.jmbbm.2021.104903] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 09/09/2021] [Accepted: 10/12/2021] [Indexed: 10/20/2022]
Abstract
The clinical relevance of bone remodelling predictions calls for accurate finite element (FE) modelling of implant-bone structure and musculoskeletal loading conditions. However, simplifications in muscle loading, material properties, has often been used in FE simulations. Bone adaptation induces changes in bone apparent density and its microstructure. Multiscale simulations, involving optimization methods and biomimetic microstructural models, have proven to be promising for predicting changes in bone morphology. The objective of the study is to develop a novel computational framework to predict bone remodelling around an uncemented femoral implant, using multiscale topology optimization and a parameterized cellular model. The efficacy of the scheme was evaluated by comparing the remodelling predictions with those of isotropic strain energy density (SED) and orthotropy based formulations. The characteristic functional groups and low-density regions of Ward's triangle, predicted by the optimization scheme, were comparable to micro-CT images of the proximal femur. Although the optimization scheme predicted well comparable material distribution in the 2D femur models, the obscured material orientations in some planes of the 3D model indicate the need for a more robust modelling of the boundary conditions. Regression analysis revealed a higher correlation (0.6472) between the topology optimization and SED models than the orthotropic predictions (0.4219). Despite higher bone apposition of 10-20% around the distal tip of the implant, the bone density distributions were well comparable to clinical observations towards the proximal femur. The proposed computational scheme appears to be a viable method for including bone anisotropy in the remodelling formulation.
Collapse
Affiliation(s)
- Basil Mathai
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India.
| |
Collapse
|
7
|
Mathai B, Dhara S, Gupta S. Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation. Biomech Model Mechanobiol 2021; 20:1115-1134. [PMID: 33768358 DOI: 10.1007/s10237-021-01436-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 02/11/2021] [Indexed: 11/25/2022]
Abstract
Peri-prosthetic bone adaptation has usually been predicted using subject-specific finite element analysis in combination with remodelling algorithms and assuming isotropic bone material property. The objective of the study is to develop an orthotropic bone remodelling algorithm for evaluation of peri-prosthetic bone adaptation in the uncemented implanted femur. The simulations considered loading conditions from a variety of daily activities. The orthotropic algorithm was tested on 2D and 3D models of the intact femur for verification of predicted results. The predicted orthotropic directionality, based on principal stress directions, was in agreement with the trabecular orientation in a micro-CT data of proximal femur. The validity of the proposed strain-based algorithm was assessed by comparing the predicted results of the orthotropic model with those of the strain-energy-density-based isotropic formulation. Despite agreement in cortical densities [Formula: see text], the isotropic remodelling algorithm tends to predict relatively higher values around the distal tip of the implant as compared to the orthotropic model. Both formulations predicted 4-8% bone resorption in the proximal femur. A linear regression analysis revealed a significant correlation [Formula: see text] between the stresses and strains on the cortex of the proximal femur, predicted by the isotropic and orthotropic formulations. Despite reasonable agreement in peri-prosthetic bone density distributions, the quantitative differences with isotropic model predictions highlight the combined influences of bone orthotropy and mechanical stimulus in the adaptation process.
Collapse
Affiliation(s)
- Basil Mathai
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal, 721 302, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal, 721 302, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal, 721 302, India.
| |
Collapse
|
8
|
Mathai B, Gupta S. The influence of loading configurations on numerical evaluation of failure mechanisms in an uncemented femoral prosthesis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2020; 36:e3353. [PMID: 32436357 DOI: 10.1002/cnm.3353] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Revised: 04/14/2020] [Accepted: 05/09/2020] [Indexed: 06/11/2023]
Abstract
The clinical relevance of numerical predictions of failure mechanisms in femoral prosthesis could be impaired due to simplification of musculoskeletal loading. This study investigated the extent to which loading configurations affect the preclinical analysis of an uncemented femoral implant. Patient-specific, CT-scan based FE models of intact and implanted femurs were developed and analysed using three loading configurations, which comprised of load cases representing daily activities. First loading configuration consisted of two load cases, each of walking and stair climbing. The second consisted of more number of load cases for each of these activities. The third included load cases of additional activities of standing up and sitting down. Failure criteria included maximum principal strains, interface debonding, implant-bone relative displacement and adaptive bone remodelling. Simplified loading configurations led to a reduction (100-1500 με) around cortical principal strains. The area prone to interface debonding were observed in the proximo-medial part of implant and was maximum when all activities were considered. This area was reduced by 35%, when simplified loading configurations were chosen. Interfacial area of 88%-96% experienced implant-bone relative displacements below 40 μm; however maximum of 110 μm was observed at the calcar region. Lack of consideration of variety of activities overestimated (30%-50%) bone resorption around the lateral part of the implant; hence, these bone remodelling results were less clinically relevant. Considering a variety daily activities along with an adequate number of load cases for each activity seemed necessary for pre-clinical evaluations of reconstructed femur.
Collapse
Affiliation(s)
- Basil Mathai
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal, India
| |
Collapse
|
9
|
Chatterjee S, Kobylinski S, Basu B. Finite Element Analysis to Probe the Influence of Acetabular Shell Design, Liner Material, and Subject Parameters on Biomechanical Response in Periprosthetic Bone. J Biomech Eng 2019; 140:2681672. [PMID: 30029239 DOI: 10.1115/1.4040249] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Indexed: 11/08/2022]
Abstract
The implant stability and biomechanical response of periprosthetic bone in acetabulum around total hip joint replacement (THR) devices depend on a host of parameters, including design of articulating materials, gait cycle and subject parameters. In this study, the impact of shell design (conventional, finned, spiked, and combined design) and liner material on the biomechanical response of periprosthetic bone has been analyzed using finite element (FE) method. Two different liner materials: high density polyethylene-20% hydroxyapatite-20% alumina (HDPE-20%HA-20%Al2O3) and highly cross-linked ultrahigh molecular weight polyethylene (HC-UHMWPE) were used. The subject parameters included bone condition and bodyweight. Physiologically relevant load cases of a gait cycle were considered. The deviation of mechanical condition of the periprosthetic bone due to implantation was least for the finned shell design. No significant deviation was observed at the bone region adjacent to the spikes and the fins. This study recommends the use of the finned design, particularly for weaker bone conditions. For stronger bones, the combined design may also be recommended for higher stability. The use of HC-UHMWPE liner was found to be better for convensional shell design. However, similar biomechanical response was captured in our FE analysis for both the liner materials in case of other shell designs. Overall, the study establishes the biomechanical response of periprosthetic bone in the acetabular with preclinically tested liner materials together with new shell design for different subject conditions.
Collapse
Affiliation(s)
- Subhomoy Chatterjee
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India
| | - Sabine Kobylinski
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Technical University of Applied Sciences Regensburg (OTH Regensburg), Regensburg 93047, Germany
| | - Bikramjit Basu
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India e-mails:
| |
Collapse
|
10
|
Mathai B, Gupta S. Numerical predictions of hip joint and muscle forces during daily activities: A comparison of musculoskeletal models. Proc Inst Mech Eng H 2019; 233:636-647. [DOI: 10.1177/0954411919840524] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Musculoskeletal loading plays an important role in pre-clinical evaluations of hip implants, in particular, bone ingrowth and bone remodelling. Joint force estimation using musculoskeletal models evolved as a viable alternative to in vivo measurement owing to the development of computational resources. This study investigated the efficiencies of four eminent open-source musculoskeletal models in order to determine the model that predicts the most accurate values of hip joint reaction and muscle forces during daily activities. Seven daily living activities of slow walking, normal walking, fast walking, sitting down, standing up, stair down and stair up were simulated in OpenSim using inverse dynamics method. Model predictions of joint kinematics, kinetics and muscle activation patterns were compared with published results. The estimated values of hip joint reaction force were found to corroborate well with in vivo measurements for each activity. Although the estimated values of hip joint reaction force were within a satisfactory range, overestimation of hip joint reaction force (75% BW of measured value) was observed during the late stance phase of walking cycles for all the models. In case of stair up, stair down, standing up and sitting down activities, the error in estimated values of hip joint reaction force were within ~20% BW of the measured value. Based on the results of our study, the London Lower Extremity Model predicted the most accurate value of hip joint reaction force and therefore can be used for applied musculoskeletal loading conditions for numerical investigations on hip implants.
Collapse
Affiliation(s)
- Basil Mathai
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| |
Collapse
|
11
|
Dutta A, Mukherjee K, Dhara S, Gupta S. Design of porous titanium scaffold for complete mandibular reconstruction: The influence of pore architecture parameters. Comput Biol Med 2019; 108:31-41. [PMID: 31003177 DOI: 10.1016/j.compbiomed.2019.03.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 03/05/2019] [Accepted: 03/05/2019] [Indexed: 01/16/2023]
Abstract
Patients having a medical history of oral cancer, infectious diseases or trauma are often advised surgical intervention with customized complete mandibular constructs (CMC) made of Titanium (Ti) scaffolds. A numerical framework based on a homogenization technique was developed to investigate the influence of pore architecture parameters on homogenized orthotropic material properties of the scaffolds. A comparative 3D Finite Element (FE) analysis of six CMC models, having homogenized orthotropic material properties, under a mastication cycle, was undertaken to pre-clinically determine the optimal CMC for a patient. Orthotropic material properties of Ti-scaffolds decreased with an increase in the inter-strut distance. Stress and strain distributions of CMC models during right molar bite were investigated. Despite small differences in stress distributions in the 'body' region of CMC models, the overall stress distribution (tensile and compressive) of CMC models (30-32 MPa) were well comparable to that of an intact mandible (34.54 MPa). Higher magnitudes of tensile strains were observed for models with 0.2 mm (9884μɛ) and 0.4 mm strut diameter (SD), both having 0.5 mm inter-strut distance (ID), at articular condyle area, body and symphysis equivalent part of the constructs. The maximum principal tensile strains were higher in the CMC models with 0.5 mm ID as compared to those having 0.3 mm ID. Comparatively, the scaffolds with lesser ID (0.3 mm) resulted in higher stiffness, thereby evoking less principal strains in the CMC models. Moreover, considering the weight of the scaffolds, the CMC models having 0.3 mm ID with 0.2 mm SD and 0.5 mm ID with 0.6 mm SD seemed most appropriate for a patient.
Collapse
Affiliation(s)
- Abir Dutta
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur, 721 302, West Bengal, India
| | - Kaushik Mukherjee
- Department of Bioengineering, Imperial College London, South Kensington, SW7 2AZ, UK; Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721 302, West Bengal, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur, 721 302, West Bengal, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721 302, West Bengal, India.
| |
Collapse
|
12
|
Ravera EP, Crespo MJ, Catalfamo Formento PA. A subject-specific integrative biomechanical framework of the pelvis for gait analysis. Proc Inst Mech Eng H 2018; 232:1083-1097. [PMID: 30280643 DOI: 10.1177/0954411918803125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Analysis of the human locomotor system using rigid-body musculoskeletal models has increased in the biomechanical community with the objective of studying muscle activations of different movements. Simultaneously, the finite element method has emerged as a complementary approach for analyzing the mechanical behavior of tissues. This study presents an integrative biomechanical framework for gait analysis by linking a musculoskeletal model and a subject-specific finite element model of the pelvis. To investigate its performance, a convergence study was performed and its sensitivity to the use of non-subject-specific material properties was studied. The total hip joint force estimated by the rigid musculoskeletal model and by the finite element model showed good agreement, suggesting that the integrative approach estimates adequately (in shape and magnitude) the hip total contact force. Previous studies found movements of up to 1.4 mm in the anterior-posterior direction, for single leg stance. These results are comparable with the displacement values found in this study: 0-0.5 mm in the sagittal axis. Maximum von Mises stress values of approximately 17 MPa were found in the pelvic bone. Comparing this results with a previous study of our group, the new findings show that the introduction of muscular boundary conditions and the flexion-extension movement of the hip reduce the regions of high stress and distributes more uniformly the stress across the pelvic bone. Thus, it is thought that muscle force has a relevant impact in reducing stresses in pelvic bone during walking of the finite element model proposed in this study. Future work will focus on including other deformable structures, such as the femur and the tibia, and subject-specific material properties.
Collapse
Affiliation(s)
- Emiliano P Ravera
- 1 Group of Analysis, Modeling, Processing and Clinician Implementation of Biomechanical Signals and Systems, Bioengineering and Bioinformatics Institute, CONICET-UNER, Oro Verde, Argentina.,2 Human Movement Research Laboratory, School of Engineering, National University of Entre Ríos (UNER), Oro Verde, Argentina
| | - Marcos J Crespo
- 3 Gait and Motion Analysis Laboratory, FLENI Institute for Neurological Research, Escobar, Argentina
| | - Paola A Catalfamo Formento
- 1 Group of Analysis, Modeling, Processing and Clinician Implementation of Biomechanical Signals and Systems, Bioengineering and Bioinformatics Institute, CONICET-UNER, Oro Verde, Argentina.,2 Human Movement Research Laboratory, School of Engineering, National University of Entre Ríos (UNER), Oro Verde, Argentina
| |
Collapse
|
13
|
Mukherjee K, Gupta S. Combined Bone Ingrowth and Remodeling Around Uncemented Acetabular Component: A Multiscale Mechanobiology-Based Finite Element Analysis. J Biomech Eng 2017; 139:2644120. [PMID: 28696483 DOI: 10.1115/1.4037223] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Indexed: 11/08/2022]
Abstract
Bone ingrowth and remodeling are two different evolutionary processes which might occur simultaneously. Both these processes are influenced by local mechanical stimulus. However, a combined study on bone ingrowth and remodeling has rarely been performed. This study is aimed at understanding the relationship between bone ingrowth and adaptation and their combined influence on fixation of the acetabular component. Based on three-dimensional (3D) macroscale finite element (FE) model of implanted pelvis and microscale FE model of implant–bone interface, a multiscale framework has been developed. The numerical prediction of peri-acetabular bone adaptation was based on a strain-energy density-based formulation. Bone ingrowth in the microscale models was simulated using the mechanoregulatory algorithm. An increase in bone strains near the acetabular rim was observed in the implanted pelvis model, whereas the central part of the acetabulum was observed to be stress shielded. Consequently, progressive bone apposition near the acetabular rim and resorption near the central region were observed. Bone remodeling caused a gradual increase in the implant–bone relative displacements. Evolutionary bone ingrowth was observed around the entire acetabular component. Poor bone ingrowth of 3–5% was predicted around the centro-inferio and inferio-posterio-superio-peripheral regions owing to higher implant–bone relative displacements, whereas the anterio-inferior and centro-superior regions exhibited improved bone ingrowth of 35–55% due to moderate implant–bone relative displacement. For an uncemented acetabular CoCrMo component, bone ingrowth had hardly any effect on bone remodeling; however, bone remodeling had considerable influence on bone ingrowth.
Collapse
Affiliation(s)
- Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Sanjay Gupta
- Professor Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India e-mail:
| |
Collapse
|
14
|
Mukherjee K, Gupta S. Influence of Implant Surface Texture Design on Peri-Acetabular Bone Ingrowth: A Mechanobiology Based Finite Element Analysis. J Biomech Eng 2017; 139:2592752. [PMID: 27925634 DOI: 10.1115/1.4035369] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Indexed: 11/08/2022]
Abstract
The fixation of uncemented acetabular components largely depends on the amount of bone ingrowth, which is influenced by the design of the implant surface texture. The objective of this numerical study is to evaluate the effect of these implant texture design factors on bone ingrowth around an acetabular component. The novelty of this study lies in comparative finite element (FE) analysis of 3D microscale models of the implant-bone interface, considering patient-specific mechanical environment, host bone material property and implant-bone relative displacement, in combination with sequential mechanoregulatory algorithm and design of experiment (DOE) based statistical framework. Results indicated that the bone ingrowth process was inhibited due to an increase in interbead spacing from 200 μm to 600 μm and bead diameter from 1000 μm to 1500 μm and a reduction in bead height from 900 μm to 600 μm. Bead height, a main effect, was found to have a predominant influence on bone ingrowth. Among the interaction effects, the combination of bead height and bead diameter was found to have a pronounced influence on bone ingrowth process. A combination of low interbead spacing (P = 200 μm), low bead diameter (D = 1000 μm), and high bead height (H = 900 μm) facilitated peri-acetabular bone ingrowth and an increase in average Young's modulus of newly formed tissue layer. Hence, such a surface texture design seemed to provide improved fixation of the acetabular component.
Collapse
Affiliation(s)
- Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India
| | - Sanjay Gupta
- Professor Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India e-mail:
| |
Collapse
|