1
|
Hsieh MK, Lee DM, Chen WP, Li YD, Kao FC, Lin YC, Tsai TT, Lai PL, Tai CL. Forcefully engaging rods into tulips with gap discrepancy leading to pedicle screw loosening-a biomechanical analysis using long porcine spine segments. Spine J 2024; 24:1773-1780. [PMID: 38499068 DOI: 10.1016/j.spinee.2024.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 02/05/2024] [Accepted: 03/12/2024] [Indexed: 03/20/2024]
Abstract
BACKGROUND CONTEXT Long-segment pedicle screw instrumentation is widely used to treat complex spinal disorders. Rods are routinely precontoured to maximize assistance on the correcting side of the deformity, but there often exists a residual gap discrepancy between the precontoured rods and screw tulips. No previous research has investigated the diminished pullout strength of the most proximal or distal pedicle screw resulting from a mismatched rod in long-segment pedicle screw instrumentation. PURPOSE The present study aimed to investigate the decreased pullout force of pedicle screws affected by the gap discrepancy when forcefully engaging a mismatched rod into a tulip in a normal-density porcine spine. STUDY DESIGN The pedicle screw fixation strength under axial pullout force was compared among three different gap discrepancies between rods and tulips using long porcine spine segments. METHODS Twelve porcine lumbar vertebrae (L3-L6) were implanted with pedicle screws and rods. Screws on one side had no gap between the tulip and rod (0-mm group), while the most proximal screw on the other side had an intentional gap of 3 mm (3-mm group) or 6 mm (6-mm group). Three hours after forcefully engaging the rod into the tulips at room temperature, the set screws in all specimens were loosened, and each specimen was dissected into individual vertebrae for subsequent pullout testing. RESULTS The control group exhibited significantly greater pullout strength (1987.68 ± 126.80 N) than the groups from different rod-tulip configurations (p<.05), with significantly greater strength in the 3-mm group (945.62 ± 97.43 N) than the 6-mm group (655.30 ± 194.49 N) (p<.05). Only 47.6% and 33.0% of the pullout strength was retained in the 3-mm and 6-mm groups, respectively, compared to the control group. CONCLUSIONS Gap discrepancies between rods and tulips can significantly reduce pedicle screw pullout strength, with a correlation between decreased strength and increased gaps. Surgeons should avoid forcefully engaging mismatched rods and consider well-fitted contoured rods in spinal surgery to minimize the risk of screw loosening. CLINICAL SIGNIFICANCE The gap discrepancy between rod and tulip significantly affected pullout strength, with greater gaps leading to reduced strength. Forcefully engaging mismatched rods into tulips in degenerative spinal surgery should be avoided to minimize the risk of early screw pullout.
Collapse
Affiliation(s)
- Ming-Kai Hsieh
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, No. 5, Fushing St., Kweishan Dist., Taoyuan City 33305, Taiwan
| | - De-Mei Lee
- Department of Mechanical Engineering, Chang Gung University, No. 259, Wenhua 1(st) Rd., Kweishan Dist., Taoyuan City 33302, Taiwan
| | - Weng-Pin Chen
- Department of Mechanical Engineering, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Daan Dist., Taipei City 10608, Taiwan
| | - Yun-Da Li
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, No. 5, Fushing St., Kweishan Dist., Taoyuan City 33305, Taiwan; Department of Biomedical Engineering, Chang Gung University, No. 259, Wenhua 1(st) Rd., Kweishan Dist., Taoyuan City 33302, Taiwan
| | - Fu-Cheng Kao
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, No. 5, Fushing St., Kweishan Dist., Taoyuan City 33305, Taiwan
| | - Yue-Chen Lin
- Department of Mechanical Engineering, Chang Gung University, No. 259, Wenhua 1(st) Rd., Kweishan Dist., Taoyuan City 33302, Taiwan
| | - Tsung-Ting Tsai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, No. 5, Fushing St., Kweishan Dist., Taoyuan City 33305, Taiwan
| | - Po-Liang Lai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, No. 5, Fushing St., Kweishan Dist., Taoyuan City 33305, Taiwan
| | - Ching-Lung Tai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, No. 5, Fushing St., Kweishan Dist., Taoyuan City 33305, Taiwan; Department of Biomedical Engineering, Chang Gung University, No. 259, Wenhua 1(st) Rd., Kweishan Dist., Taoyuan City 33302, Taiwan.
| |
Collapse
|
2
|
Zhang C, Guo LX. Effect of whole-body vibration at different frequencies on the lumbar spine: A finite element study based on a whole human body model. Proc Inst Mech Eng H 2022; 236:1752-1761. [DOI: 10.1177/09544119221135688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Many previous studies have found that occupational drivers commonly suffered from low back pain, and low back pain and degeneration of the intervertebral disc might be associated with vibration conditions. However, the biomechanical mechanisms of whole-body vibration that caused pain and injury were not clear. In this study, a validated whole human body finite element model was used, and vibration loads at frequencies of 3, 5, 7 and 9 Hz were loaded to evaluate the frequency effects on the spine. The results showed that the responses of the spine were strong at the 5 Hz vibration load. Vibration loads would produce alternating stresses and bulges in the annulus fibrosus and change the direction of the pressure in the nucleus pulposus. The posterior region of the intervertebral disc showed greater stress fluctuations than the anterior region. The Risk Factors showed that long-term exposure to whole-body vibrations at 5 and 7 Hz might have greater adverse effects on the spine. The findings of this study confirmed that vibrations near the resonance frequency of the human body would cause more injuries to the spine than other frequencies. Alternating stress and bulge might cause fatigue and the degeneration of the intervertebral disc, which might be the mechanisms of spinal injury caused by whole-body vibration, and the posterior regions of the intervertebral disc were more susceptible to degeneration. Some appropriate measures should be taken to reduce the adverse effects of whole-body vibration on spinal health.
Collapse
Affiliation(s)
- Chi Zhang
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| | - Li-Xin Guo
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| |
Collapse
|