1
|
Guleken Z, Ceylan Z, Aday A, Bayrak AG, Hindilerden İY, Nalçacı M, Jakubczyk P, Jakubczyk D, Depciuch J. Application of Fourier Transform InfraRed spectroscopy of machine learning with Support Vector Machine and principal components analysis to detect biochemical changes in dried serum of patients with primary myelofibrosis. Biochim Biophys Acta Gen Subj 2023; 1867:130438. [PMID: 37516257 DOI: 10.1016/j.bbagen.2023.130438] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 07/24/2023] [Accepted: 07/24/2023] [Indexed: 07/31/2023]
Abstract
Primary myelofibrosis (PM) is a myeloproliferative neoplasm characterized by stem cell-derived clonal neoplasms. Several factors are involved in diagnosing PM, including physical examination, peripheral blood findings, bone marrow morphology, cytogenetics, and molecular markers. Commonly gene mutations are used. Also, these gene mutations exist in other diseases, such as polycythemia vera and essential thrombocythemia. Hence, understanding the molecular mechanism and finding disease-related biomarker characteristics only for PM is crucial for the treatment and survival rate. For this purpose, blood samples of PM (n = 85) vs. healthy controls (n = 45) were collected for biochemical analysis, and, for the first time, Fourier Transform InfraRed (FTIR) spectroscopy measurement of dried PM and healthy patients' blood serum was analyzed. A Support Vector Machine (SVM) model with optimized hyperparameters was constructed using the grid search (GS) method. Then, the FTIR spectra of the biomolecular components of blood serum from PM patients were compared to those from healthy individuals using Principal Components Analysis (PCA). Also, an analysis of the rate of change of FTIR spectra absorption was studied. The results showed that PM patients have higher amounts of phospholipids and proteins and a lower amount of H-O=H vibrations which was visible. The PCA results indicated that it is possible to differentiate between dried blood serum samples collected from PM patients and healthy individuals. The Grid Search Support Vector Machine (GS-SVM) model showed that the prediction accuracy ranged from 0.923 to 1.00 depending on the FTIR range analyzed. Furthermore, it was shown that the ratio between α-helix and β-sheet structures in proteins is 1.5 times higher in PM than in control people. The vibrations associated with the CO bond and the amide III region of proteins showed the highest probability value, indicating that these spectral features were significantly altered in PM patients compared to healthy ones' spectra. The results indicate that the FTIR spectroscope may be used as a technique helpful in PM diagnostics. The study also presents preliminary results from the first prospective clinical validation study.
Collapse
Affiliation(s)
- Zozan Guleken
- Gaziantep University of Islam Science and Technology, Faculty of Medicine, Department of Physiology, Küçükkızılhisar, 27220 Şahinbey/Gaziantep, Turkey (b)Medical College of Rzeszow University, Rzeszów, Poland; Medical College of Rzeszow University, Rzeszów, Poland.
| | - Zeynep Ceylan
- Samsun University, Faculty of Engineering, Department of Industrial Engineering, Samsun, Turkey
| | - Aynur Aday
- Istanbul University, Faculty of Medicine, Department of Internal Medicine, Division of Medical Genetics, Istanbul, Turkey
| | - Ayşe Gül Bayrak
- Istanbul University, Faculty of Medicine, Department of Internal Medicine, Division of Medical Genetics, Istanbul, Turkey
| | - İpek Yönal Hindilerden
- Istanbul University Istanbul Faculty of Medicine, Department of Internal Medicine, Division of Hematology, Istanbul, Turkey
| | - Meliha Nalçacı
- Istanbul University Istanbul Faculty of Medicine, Department of Internal Medicine, Division of Hematology, Istanbul, Turkey
| | | | - Dorota Jakubczyk
- Faculty of Mathematics and Applied Physics, Rzeszow University of Technology, Powstancow Warszawy 12, PL-35959 Rzeszow, Poland
| | - Joanna Depciuch
- Institute of Nuclear Physics, PAS, 31342 Krakow, Poland; Department of Biochemistry and Molecular Biology, Medical University of Lublin, 20-093 Lublin, Poland.
| |
Collapse
|
2
|
Guleken Z, Ceylan Z, Aday A, Bayrak AG, Hindilerden İY, Nalçacı M, Jakubczyk P, Jakubczyk D, Depciuch J. FTIR- based serum structure analysis in molecular diagnostics of essential thrombocythemia disease. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 2023; 245:112734. [PMID: 37295134 DOI: 10.1016/j.jphotobiol.2023.112734] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 04/18/2023] [Accepted: 05/30/2023] [Indexed: 06/12/2023]
Abstract
Essential thrombocythemia (ET) reflects the transformation of a multipotent hematopoietic stem cell, but its molecular pathogenesis remains obscure. Nevertheless, tyrosine kinase, especially Janus kinase 2 (JAK2), has been implicated in myeloproliferative disorders other than chronic myeloid leukaemia. FTIR analysis was performed on the blood serum of 86 patients and 45 healthy volunteers as control with FTIR spectra-based machine learning methods and chemometrics. Thus, the study aimed to determine biomolecular changes and separation of ET and healthy control groups illustration by applying chemometrics and ML techniques to spectral data. The FTIR-based results showed that in ET disease with JAK2 mutation, there are alterations in functional groups associated with lipids, proteins and nucleic acids significantly. Moreover, in ET patients the lower amount of proteins with simultaneously higher amount of lipids was noted in comparison with the control one. Furthermore, the SVM-DA model showed 100% accuracy in calibration sets in both spectral regions and 100.0% and 96.43% accuracy in prediction sets for the 800-1800 cm-1 and 2700-3000 cm-1 spectral regions, respectively. While changes in the dynamic spectra showed that CH2 bending, amide II and CO vibrations could be used as a spectroscopy marker of ET. Finally, it was found a positive correlation between FTIR peaks and first bone marrow fibrosis degree, as well as the absence of JAK2 V617F mutation. The findings of this study contribute to a better understanding of the molecular pathogenesis of ET and identifying biomolecular changes and may have implications for early diagnosis and treatment of this disease.
Collapse
Affiliation(s)
- Zozan Guleken
- Department of Physiology, Faculty of Medicine, Gaziantep, Islam, Science and Technology University, 27220, Gaziantep, Turkey.
| | - Zeynep Ceylan
- Samsun University, Faculty of Engineering, Department of Industrial Engineering, Turkey
| | - Aynur Aday
- Istanbul University, Faculty of Medicine, Department of Internal Medicine, Division of Medical Genetics, Turkey
| | - Ayşe Gül Bayrak
- Istanbul University, Faculty of Medicine, Department of Internal Medicine, Division of Medical Genetics, Turkey
| | - İpek Yönal Hindilerden
- Istanbul University Istanbul Faculty of Medicine, Department of Internal Medicine, Division of Hematology, Turkey
| | - Meliha Nalçacı
- Istanbul University Istanbul Faculty of Medicine, Department of Internal Medicine, Division of Hematology, Turkey
| | | | - Dorota Jakubczyk
- Faculty of Mathematics and Applied Physics, Rzeszow University of Technology, Powstancow Warszawy 12, PL-35959 Rzeszow, Poland
| | - Joanna Depciuch
- Institute of Nuclear Physics, PAS, 31342 Krakow, Poland; Department of Biochemistry and Molecular Biology, Medical University of Lublin, 20-093 Lublin, Poland
| |
Collapse
|
3
|
COMPARISON OF DIAGNOSTIC PREDICTORS OF NEONATAL SURVIVABILITY IN NONDOMESTIC CAPRINAE. J Zoo Wildl Med 2022; 53:31-40. [DOI: 10.1638/2020-0064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/20/2021] [Indexed: 11/21/2022] Open
|
4
|
Sharafeldin M, Davis JJ. Characterising the biosensing interface. Anal Chim Acta 2022; 1216:339759. [DOI: 10.1016/j.aca.2022.339759] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/08/2022] [Accepted: 03/22/2022] [Indexed: 12/19/2022]
|
5
|
Bel’skaya LV, Sarf EA, Solomatin DV. Application of FTIR Spectroscopy for Quantitative Analysis of Blood Serum: A Preliminary Study. Diagnostics (Basel) 2021; 11:diagnostics11122391. [PMID: 34943626 PMCID: PMC8700755 DOI: 10.3390/diagnostics11122391] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 12/14/2021] [Accepted: 12/17/2021] [Indexed: 11/16/2022] Open
Abstract
The aim of this study was to analyze the possibility of simultaneous determination of the concentration of components from the characteristics of FTIR spectra using the example of a model blood serum. To prepare model solutions, a set of freeze-dried control sera based on bovine blood serum was used, certified for approximately 38 parameters. Based on the values of the absorbance and areas of absorption bands in the FTIR spectra of model solutions, a regression equation was constructed by solving a nonlinear problem using the generalized reduced gradient method. By using the absorbance of the absorption bands at 1717 and 3903 cm−1 and the areas of the absorption bands at 616, 3750, and 3903 cm−1, it is possible to simultaneously determine the concentrations of 38 components with an error of less than 0.1%. The results obtained confirm the potential clinical use of FTIR spectroscopy as a reagent-free express method for the analysis of blood serum. However, its practical implementation requires additional research, in particular, analysis of real blood serum samples and validation of the method.
Collapse
Affiliation(s)
- Lyudmila V. Bel’skaya
- Biochemistry Research Laboratory, Omsk State Pedagogical University, 644099 Omsk, Russia;
- Correspondence:
| | - Elena A. Sarf
- Biochemistry Research Laboratory, Omsk State Pedagogical University, 644099 Omsk, Russia;
| | - Denis V. Solomatin
- Department of Mathematics and Mathematics Teaching Methods, Omsk State Pedagogical University, 644043 Omsk, Russia;
| |
Collapse
|
6
|
Current Diagnostic Methods for Assessing Transfer of Passive Immunity in Calves and Possible Improvements: A Literature Review. Animals (Basel) 2021; 11:ani11102963. [PMID: 34679982 PMCID: PMC8532593 DOI: 10.3390/ani11102963] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 09/29/2021] [Accepted: 10/05/2021] [Indexed: 12/26/2022] Open
Abstract
Simple Summary The transfer of passive immunity (TPI) from cows to calves needs to be routinely assessed on farms and in field research. The gold standard method for assessing TPI is radial immunodiffusion (RID) because it directly assesses the immunoglobulin G (IgG) concentration in calf serum samples. In addition to RID, there are several other methods available for the assessment of TPI which determine the concentration of IgG or other serum components. It is known that several components present in the colostrum are absorbed by the calves and aid passive immunity. We conducted a literature review of the methods scientifically reported by experts in the field. Abstract Several direct or indirect methods can be used to assess immunoglobulin G (IgG) concentrations in calves, which evaluates the transfer of passive immunity (TPI). Radial immunodiffusion (RID) is the gold standard method to measure serum IgG in bovines. Previous studies have shown that colostrum provides several molecules in addition to immunoglobulins, which play an important role in the passive immunity of the calf. However, no studies have yet determined the level of interference of these components in the immunity, health and survival of calves. In this sense, the objective of this study is to review the methods of evaluation available for the laboratory and field diagnosis of TPI in calves and discuss the main aspects of each technique. Several methods available for TPI evaluation in calves may provide insights into the various components of colostrum involved in passive immunity.
Collapse
|
7
|
Field E, Scurr DJ, Piggott MJ, Anderson TS, Chanoit GP. The chemical and ultra-structural analysis of thin plastic films used for surgical attenuation of portosystemic shunts in dogs and cats. Res Vet Sci 2019; 126:192-198. [PMID: 31539796 DOI: 10.1016/j.rvsc.2019.08.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 08/05/2019] [Accepted: 08/12/2019] [Indexed: 11/16/2022]
Abstract
The objective of the study was to (1) characterize and compare the chemical composition at the surface, subsurface and in the bulk of thin plastic films used for portosystemic shunt attenuation in their native state and after plasma exposure. (2) Assess the presence, concentration and location of irritant compounds (e.g dicetyl phosphate) within the films. Attenuated Total Reflectance Infrared Spectroscopy (ATR-IR), X-ray Photoelectron Spectroscopy (XPS) and dynamic Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) were used to analyze thirteen thin plastic films. Sample thickness was visualized and measured using Scanning Electron Microscopy (SEM). Sample thicknesses were compared using a one-way ANOVA. XPS reported low phosphorous concentrations (surrogate marker of dicetyl phosphate) between 0.01 and 0.19% wt at the sample surfaces (top 10 nm). There were significant differences between film thicknesses (P < .001) observed by SEM. The ATR-IR and ToF-SIMS identified four distinct surface and bulk chemical profiles: 1) Cellophane, 2) Polypropylene, 3) Modified Cellophane, and 4) Unique. Following plasma immersion for 6 weeks, samples showed little change in film thickness or chemical composition. This study confirmed that films used to attenuate portosystemic shunts were commonly not pure cellophane, with significant variations in surface and bulk chemistry. Suspected irritant compounds were not readily identifiable in significant proportions. Pronounced variability existed in both the thickness and chemical composition of these films (surface vs. bulk). The present findings lead to a legitimate question about the reproducibility of shunt occlusion when using thin plastic films from different origins.
Collapse
Affiliation(s)
- ElinorJ Field
- University of Bristol, Faculty of Health and Science, Bristol Veterinary School, UK
| | - David J Scurr
- University of Nottingham, School of Pharmacy, Advanced Materials and Healthcare Technologies, UK
| | - Matthew J Piggott
- University of Nottingham, School of Pharmacy, Advanced Materials and Healthcare Technologies, UK
| | - Thomas S Anderson
- University of Bristol, Faculty of Health and Science, Bristol Veterinary School, UK
| | - Guillaume P Chanoit
- University of Bristol, Faculty of Health and Science, Bristol Veterinary School, UK.
| |
Collapse
|
8
|
Elsohaby I, Mweu MM, Mahmmod YS, McClure JT, Keefe GP. Diagnostic performance of direct and indirect methods for assessing failure of transfer of passive immunity in dairy calves using latent class analysis. Prev Vet Med 2019; 164:72-77. [PMID: 30771896 DOI: 10.1016/j.prevetmed.2019.02.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2018] [Revised: 12/29/2018] [Accepted: 02/04/2019] [Indexed: 10/27/2022]
Abstract
Accurate diagnosis of failure of transfer of passive immunity (FTPI) in newborn calves is an essential component of dairy farm management plan. Several methods (direct and indirect) are available for diagnosis of FTPI in dairy calves. However, the indirect methods offer an advantage over the direct methods in not requiring an experienced veterinarian, rapid, cost efficient and can be performed under field-setting. The objective of this study was to estimate the diagnostic performance of radial immunodiffusion (RID) assay, transmission infrared (TIR) spectroscopy and digital Brix refractometer for diagnosis of FTPI in dairy calves using latent class models at four cut-off values of digital Brix refractometer. Holstein calves (n = 691) from 40 commercial dairy farms in the four Atlantic Canada provinces were blood-sampled and tested for detection of FTPI. Results showed that the number of calves with FTPI was 253 (36.6%) by RID, 194 (28.1%) by TIR and 204 (29.5%) by Brix refractometer at cut-off value of 8.2%. Estimates of SeRID was higher than SeTIR and SeBrix, at all Brix refractometer cut-offs, but with increase of Brix refractometer cut-off from 8.2 to 8.5%, SeRID and SeTIR were decreased from 96.0% (95% PCI: 88.0-99.0) and 79.0% (95% PCI: 70.0-85.0), to 92.0% (95% PCI: 77.0-99.0) and 74.0% (95% PCI: 61.0-82.0), respectively. SpRID and SpTIR were always higher than SpBrix at all tested cut-offs and were above 92.0%, and 96.0%, respectively. With increasing the cut-off of Brix refractometer from 8.2 to 8.5%, SeBrix estimate has remarkably increased from 79.0% (95% PCI: 70.0-96.0) to 95.0% (95% PCI: 87.0-100.0), respectively. Whilst, SpBrix was decreased from 95.0% (95% PCI: 91.0-98.0) at cut-off 8.2% to 84.0% (95% PCI: 78.0-94.0) at cut-off 8.5%. In conclusion, RID has a higher Se than TIR and Brix, if the latter is used with cut-offs of 8.2% or 8.3%. However, the higher the cut-off, the more comparable sensitivities of RID and digital Brix refractometer. The median estimate of SpTIR was always higher than SpRID and SpBrix at all tested cut-offs. However, the 95% confidence interval estimates of the three tests were overlapping across the tested cut-offs of digital Brix refractometer reflecting the inability to prefer a test over the other based on the Sp estimate.
Collapse
Affiliation(s)
- Ibrahim Elsohaby
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada; Department of Animal Medicine, Division of Infectious Diseases, Faculty of Veterinary Medicine, Zagazig University, Zagazig City, Sharkia Province, Egypt.
| | - Marshal M Mweu
- School of Public Health, College of Health Sciences, University of Nairobi, Nairobi, Kenya
| | - Yasser S Mahmmod
- Department of Animal Medicine, Division of Infectious Diseases, Faculty of Veterinary Medicine, Zagazig University, Zagazig City, Sharkia Province, Egypt; IRTA, Centre de Recerca en Sanitat Animal (CReSA, IRTA), Campus de la Universitat Autònoma de Barcelona, 08193, Bellaterra, Cerdanyola del Vallès, Barcelona, Spain; Universitat Autònoma de Barcelona, 08193, Bellaterra, Cerdanyola del Vallès, Barcelona, Spain
| | - J Trenton McClure
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada
| | - Greg P Keefe
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada
| |
Collapse
|
9
|
Elsohaby I, McClure JT, Waite LA, Cameron M, Heider LC, Keefe GP. Using serum and plasma samples to assess failure of transfer of passive immunity in dairy calves. J Dairy Sci 2018; 102:567-577. [PMID: 30415862 DOI: 10.3168/jds.2018-15070] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 09/23/2018] [Indexed: 11/19/2022]
Abstract
The objectives of this study were (1) to determine the differences in IgG and total protein (TP) content of serum and plasma samples collected from the same calves; (2) to evaluate the correlation between calf serum and plasma IgG levels, Brix scores, and TP concentrations; (3) to determine whether different cut-off values should be used for plasma and serum to assess failure of transfer of passive immunity (FTPI) in dairy calves; and (4) to evaluate the level of agreement between results obtained from using serum and plasma samples of the same calves to assess FTPI using optimal cut-off values. Blood samples (n = 217) were collected from Holstein calves at 3 to 10 d of age on 30 commercial dairy farms in Nova Scotia and Newfoundland, Canada. Paired serum and plasma samples were analyzed for IgG concentration by the reference radial immunodiffusion assay, transmission infrared (TIR) spectroscopy, digital and optical Brix refractometers, and optical TP refractometer. The IgG concentrations measured by RID and TIR spectroscopy in serum were similar to those in plasma. However, the Brix and TP refractometer readings were significantly higher in plasma than in serum. The prevalence of FTPI in serum and plasma samples based on a RID-IgG concentration <10 g/L was 43.3 and 46.5%, respectively. The RID-IgG concentration was correlated with TIR-IgG (r = 0.92 and 0.89), digital Brix (r = 0.80 and 0.80), optical Brix (r = 0.77 and 0.77), and optical TP (r = 0.75 and 0.77) refractometers in serum and plasma, respectively. The correlations between paired serum and plasma IgG content were 0.85 by TIR spectroscopy, 0.80 by digital Brix, 0.77 by optical Brix, and 0.79 by optical TP refractometer. The optimal cut-off values for TIR spectroscopy, digital Brix, optical Brix, and TP refractometers to assess FTPI using serum were 13.1 g/L, 8.7% Brix, 8.4% Brix and 5.1 g/dL, respectively; and the optimal cut-off values with plasma were 13.4 g/L, 9.4% Brix, 9.3% Brix and 5.8 g/dL, respectively. When using these optimal cut-off values, the level of agreement (88.1%) between results derived from testing serum and plasma by TIR spectroscopy was substantial, with a kappa (κ) value of 0.76. The results derived from testing serum and plasma by digital Brix refractometer showed substantial agreement (83.4%), with a κ value of 0.65, which is higher than the agreement and κ value (74.7% and 0.51) reported for the optical Brix refractometer. Substantial agreement (81.6%) between serum and plasma TP was also obtained when using the optical TP refractometer, with a κ value of 0.63. In conclusion, serum or plasma samples can be used interchangeably for measuring IgG concentrations and assessing FTPI in dairy calves. However, different cut-offs must be used to assess FTPI depending on the sample matrix. Furthermore, results obtained from serum samples showed higher agreement with the reference RID assay than those obtained from plasma samples.
Collapse
Affiliation(s)
- I Elsohaby
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3; Department of Animal Medicine, Division of Infectious Diseases, Faculty of Veterinary Medicine, Zagazig University, Zagazig City 44511, Sharkia Province, Egypt.
| | - J T McClure
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| | - L A Waite
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| | - M Cameron
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| | - L C Heider
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| | - G P Keefe
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| |
Collapse
|
10
|
Todd CG, McGee M, Tiernan K, Crosson P, O'Riordan E, McClure J, Lorenz I, Earley B. An observational study on passive immunity in Irish suckler beef and dairy calves: Tests for failure of passive transfer of immunity and associations with health and performance. Prev Vet Med 2018; 159:182-195. [PMID: 30314781 DOI: 10.1016/j.prevetmed.2018.07.014] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Revised: 06/19/2018] [Accepted: 07/24/2018] [Indexed: 10/28/2022]
Abstract
The study objectives were to: 1) evaluate the diagnostic performance of passive immunity tests for classification of failure of passive transfer (FPT) risk, based on their relationships with calf health and performance, and 2) describe the epidemiology of morbidity and mortality in suckler beef and dairy calves under Irish conditions. A total of 1392 suckler beef calves (n = 111 farms) and 2090 dairy calves (84 farms) were included in this observational study. Blood samples were collected by jugular venipuncture. Serum samples were analysed for total IgG concentration using an ELISA assay, total protein concentration by clinical analyser (TP - CA), globulin concentration, zinc sulphate turbidity (ZST) units, total solids percentage by Brix refractometer (TS - BRIX), and total protein concentration by digital refractometer (TP - DR). Crude and cause-specific morbidity, all-cause mortality, and standardised 205-day body weight (BW) were determined. Generalised linear mixed models were used to evaluate associations between suckler beef and dairy calves for morbidity, mortality, growth and passive immunity. Receiver operating characteristic (ROC) curves were constructed to determine optimal test cut-offs for classification of health and growth outcomes. Overall, 20% of suckler beef and 30% of dairy calves were treated for at least one disease event by 6 mo. of age. Suckler beef calves had greater odds of bovine respiratory disease (BRD; odds ratio (OR), 95% confidence interval (CI): 2.8, 1.2-6.5, P = 0.01), navel infection (5.1, 1.9-13.2, P < 0.001), and joint infection/lameness (3.2, 1.3-7.8, P = 0.01) during the first 6 mo. of life than dairy calves. In addition, from birth to 6 mo. of age, suckler beef calves had greater rates of navel infection (incidence rate ratio (IRR), 95% CI: 3.3, 1.3-8.4, P = 0.01), but decreased rates of diarrhoea (0.9, 0.2-0.9, P = 0.03) compared to dairy calves. Optimal test cut-offs for classification of morbidity and mortality outcomes in suckler beef calves ranged from 8 to 9 mg/ml ELISA, 56 to 61 g/l TP - CA, 26 to 40 g/l globulin, 12 to 18 ZST units, 8.4% TS - BRIX, and 5.3 to 6.3 g/dl TP - DR. Optimal test cut-offs for classification of morbidity and growth outcomes in dairy calves ranged from 10 to 12 mg/ml ELISA, 57 to 60 g/l TP - CA, 29 to 34 g/l globulin, 19 ZST units, 7.8 to 8.4% TS - BRIX, and 5.7 to 5.9 g/dl TP - DR.
Collapse
Affiliation(s)
- C G Todd
- Animal & Grassland Research and Innovation Centre, Teagasc, Grange, Dunsany, Co. Meath, Ireland
| | - M McGee
- Animal & Grassland Research and Innovation Centre, Teagasc, Grange, Dunsany, Co. Meath, Ireland
| | - K Tiernan
- Animal & Grassland Research and Innovation Centre, Teagasc, Grange, Dunsany, Co. Meath, Ireland; School of Veterinary Medicine, University College Dublin, Belfield, Dublin 4, Co. Dublin, Ireland
| | - P Crosson
- Animal & Grassland Research and Innovation Centre, Teagasc, Grange, Dunsany, Co. Meath, Ireland
| | - E O'Riordan
- Animal & Grassland Research and Innovation Centre, Teagasc, Grange, Dunsany, Co. Meath, Ireland
| | - J McClure
- Irish Cattle Breeding Federation, Bandon, Co. Cork, Ireland
| | - I Lorenz
- School of Veterinary Medicine, University College Dublin, Belfield, Dublin 4, Co. Dublin, Ireland; Bavarian Animal Health Service, Poing, Germany
| | - B Earley
- Animal & Grassland Research and Innovation Centre, Teagasc, Grange, Dunsany, Co. Meath, Ireland.
| |
Collapse
|
11
|
Elsohaby I, McClure JT, Riley CB, Bryanton J, Bigsby K, Shaw RA. Centrifugal ultrafiltration of human serum for improving immunoglobulin A quantification using attenuated total reflectance infrared spectroscopy. J Pharm Biomed Anal 2017; 150:413-419. [PMID: 29288967 DOI: 10.1016/j.jpba.2017.12.031] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 11/23/2017] [Accepted: 12/15/2017] [Indexed: 01/31/2023]
Abstract
Attenuated total reflectance infrared (ATR-IR) spectroscopy is a simple, rapid and cost-effective method for the analysis of serum. However, the complex nature of serum remains a limiting factor to the reliability of this method. We investigated the benefits of coupling the centrifugal ultrafiltration with ATR-IR spectroscopy for quantification of human serum IgA concentration. Human serum samples (n = 196) were analyzed for IgA using an immunoturbidimetric assay. ATR-IR spectra were acquired for whole serum samples and for the retentate (residue) reconstituted with saline following 300 kDa centrifugal ultrafiltration. IR-based analytical methods were developed for each of the two spectroscopic datasets, and the accuracy of each of the two methods compared. Analytical methods were based upon partial least squares regression (PLSR) calibration models - one with 5-PLS factors (for whole serum) and the second with 9-PLS factors (for the reconstituted retentate). Comparison of the two sets of IR-based analytical results to reference IgA values revealed improvements in the Pearson correlation coefficient (from 0.66 to 0.76), and the root mean squared error of prediction in IR-based IgA concentrations (from 102 to 79 mg/dL) for the ultrafiltration retentate-based method as compared to the method built upon whole serum spectra. Depleting human serum low molecular weight proteins using a 300 kDa centrifugal filter thus enhances the accuracy IgA quantification by ATR-IR spectroscopy. Further evaluation and optimization of this general approach may ultimately lead to routine analysis of a range of high molecular-weight analytical targets that are otherwise unsuitable for IR-based analysis.
Collapse
Affiliation(s)
- Ibrahim Elsohaby
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, C1A 4P3, Canada; Department of Animal Medicine, Division of Infectious Diseases, Faculty of Veterinary Medicine, Zagazig University, Zagazig City 44511, Sharkia Province, Egypt.
| | - J Trenton McClure
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, C1A 4P3, Canada
| | - Christopher B Riley
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, C1A 4P3, Canada; Institute of Veterinary, Animal and Biomedical Sciences, Massey University, Palmerston North 4442, New Zealand
| | - Janet Bryanton
- School of Nursing, University of Prince Edward Island, Charlottetown, Prince Edward Island, C1A 4P3, Canada
| | - Kathryn Bigsby
- Queen Elizabeth Hospital, Charlottetown, Prince Edward Island, C1A 8T5, Canada
| | - R Anthony Shaw
- National Research Council of Canada, Medical Devices Portfolio, Winnipeg, Manitoba, R3B 1Y6, Canada
| |
Collapse
|
12
|
Bonnier F, Blasco H, Wasselet C, Brachet G, Respaud R, Carvalho LFCS, Bertrand D, Baker MJ, Byrne HJ, Chourpa I. Ultra-filtration of human serum for improved quantitative analysis of low molecular weight biomarkers using ATR-IR spectroscopy. Analyst 2017; 142:1285-1298. [DOI: 10.1039/c6an01888b] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Monitoring of changes in the concentrations of the low molecular weight constituents enhanced by abundant proteins depletion.
Collapse
Affiliation(s)
- Franck Bonnier
- Université François-Rabelais de Tours
- Faculté de Pharmacie
- EA 6295 Nanomédicaments et Nanosondes
- 37200 Tours
- France
| | - Hélène Blasco
- CHRU de Tours
- Laboratoire de Biochimie et de Biologie Moléculaire
- Tours
- France
- INSERM
| | - Clément Wasselet
- Université François-Rabelais de Tours
- Faculté de Pharmacie
- EA 6295 Nanomédicaments et Nanosondes
- 37200 Tours
- France
| | - Guillaume Brachet
- Université François Rabelais de Tours
- UMR CNRS 7292 Génétique
- Immunothérapie
- Chimie et Cancer
- Faculté de Médecine
| | - Renaud Respaud
- Université François-Rabelais de Tours
- UMR 1100
- CHRU de Tours
- Service de Pharmacie
- F-37032 Tours
| | - Luis Felipe C. S. Carvalho
- Universidade do Vale do Paraiba
- Laboratory of Biomedical Vibrational Spectroscopy
- Sao José dos Campos
- Brazil
| | | | - Matthew J. Baker
- WestCHEM
- Technology and Innovation Centre
- Department of Pure and Applied Chemistry
- University of Strathclyde
- Glasgow G1 1XL
| | - Hugh J. Byrne
- FOCAS Research Institute
- Dublin Institute of Technology (DIT)
- Dublin 8
- Ireland
| | - Igor Chourpa
- Université François-Rabelais de Tours
- Faculté de Pharmacie
- EA 6295 Nanomédicaments et Nanosondes
- 37200 Tours
- France
| |
Collapse
|
13
|
Elsohaby I, McClure JT, Cameron M, Heider LC, Keefe GP. Rapid assessment of bovine colostrum quality: How reliable are transmission infrared spectroscopy and digital and optical refractometers? J Dairy Sci 2016; 100:1427-1435. [PMID: 27988130 DOI: 10.3168/jds.2016-11824] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Accepted: 10/25/2016] [Indexed: 11/19/2022]
Abstract
The objectives of this study were to evaluate the performance of the transmission infrared (IR) spectroscopic method and digital and optical Brix refractometers for measurement of colostral IgG concentration and assessment of colostrum quality of dairy cows. Colostrum samples (n = 258) were collected from Holstein cows on 30 commercial dairy farms in Nova Scotia and Newfoundland, Canada. Colostral IgG concentrations of 255 samples were measured by the reference radial immunodiffusion (RID) assay and IR spectroscopy. The Brix scores were determined on 240 of these samples using both the digital and optical Brix refractometers. Approximately half (48%) of the colostrum samples had RID IgG concentrations <50 g/L, which was the cut-point for poor quality. The correlation between RID and IR IgG concentrations was 0.88. The correlations between RID IgG concentration and Brix scores, as determined by the digital and optical refractometers, were 0.72 and 0.71, respectively. The optimal cutoff levels for distinguishing good- and poor-quality colostrum using IR spectroscopy, and digital and optical Brix refractometers were at 35 g/L and 23% Brix, respectively. The IR spectroscopy showed higher sensitivity (90%) and specificity (86%) than the digital (74 and 80%, respectively) and optical (73 and 80%, respectively) Brix refractometers for assessment of colostrum quality, as compared with RID. In conclusion, the transmission-IR spectroscopy is a rapid and accurate method for assessing colostrum quality, but is a laboratory-based method, whereas Brix refractometers were less accurate but could be used on-farm.
Collapse
Affiliation(s)
- I Elsohaby
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3; Infectious Diseases, Department of Animal Medicine, Faculty of Veterinary Medicine, Zagazig University, Zagazig City 44511, Sharkia Province, Egypt.
| | - J T McClure
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| | - M Cameron
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| | - L C Heider
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| | - G P Keefe
- Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3
| |
Collapse
|