1
|
Regal A, Tuifua TS, Scharer BM, DeVries JG. Effect of Preoperative Coronal Plane Alignment on Actual Versus Predicted Alignment Using Patient Specific Instrumentation in Total Ankle Replacement. J Foot Ankle Surg 2024; 63:724-730. [PMID: 39098649 DOI: 10.1053/j.jfas.2024.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Revised: 06/24/2024] [Accepted: 07/25/2024] [Indexed: 08/06/2024]
Abstract
Alignment in total ankle replacement is important for success and implant survival. Recently there has been the introduction and adoption of patient specific instrumentation for implantation in total ankle replacement. Current literature does not evaluate the effect of preoperative deformity on accuracy of patient specific instrumentation. A retrospective radiographic analysis was performed on 97 consecutive patients receiving total ankle replacement with patient specific instrumentation to assess the accuracy and reproducibility of the instrumentation. Subgroup analysis evaluated the effect of preoperative deformity. All surgeries were performed by fellowship trained foot and ankle surgeons without industry ties to the implants used. Preoperative and postoperative films were compared to plans based on computerized tomography scans to assess how closely the plan would be implemented in patients. Overall postoperative coronal plane alignment was within 2° of predicted in 87.6% (85 patients). Similarly, overall postoperative sagittal plane alignment was within 2° of predicted in 88.7% (86 patients). Tibial implant size was accurately predicted in 81.4% (79 patients), and talus implant size was correct in 75.3% (73 patients). Patients with preoperative varus deformity had a higher difference between predicted and actual postoperative alignment compared to valgus deformity (1.1° compared to 0.3°, p = .02). A higher average procedure time was found in varus patients, and more adjunctive procedures were needed in patients with varus or valgus deformity, but these were not significant, p > .5. Surgeons can expect a high degree of accuracy when using patient specific instrumentation overall, but less accurate in varus deformity.
Collapse
Affiliation(s)
- Andrew Regal
- Podiatric Medicine and Surgery Residency, Ascension Wisconsin Hospital, Milwaukee, WI.
| | - Tisileli S Tuifua
- Radiology Department, Aurora St. Luke's Medical Center, Milwaukee, WI
| | | | | |
Collapse
|
2
|
van Es LJM, Sierevelt IN, Kerkhoffs GMMJ, Haverkamp D. Analyzing Learning Curve Effects: Total Ankle Replacement Design Switch and Long-Term Survival. J Foot Ankle Surg 2024; 63:593-597. [PMID: 38909964 DOI: 10.1053/j.jfas.2024.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 06/05/2024] [Accepted: 06/08/2024] [Indexed: 06/25/2024]
Abstract
Different aspects of the learning curve in total ankle replacement (TAR) have been studied in the short to mid-term, with 30 cases often considered critical. However, its impact on long-term (10- and 15-year) survival remains unclear. Therefore, we retrospectively analyzed 77 consecutive TARs performed by one orthopedic surgeon. The main outcome was long-term survival between cases 1-30 and 31-77 using the Kaplan-Meier with Competing Risk Analyses. Secondarily, we used Moving Average Method with LOESS regression to confirm the learning curve based on the perioperative complications. Thirdly, associations between perioperative complications and operation time on long-term survival were assessed using Cox proportional hazard models. The 10-year survival of cases 1-30 was 89.9% (95% CI 70.4-96.5), and of 31-77, 92.4% (95% CI 7745- 97.5) (p = .58). The 15-year survival was 81.8% (95% CI 59.5-91.8) and 74.8% (95% CI 52.4-86.6), respectively (p = .97). The long-term survival rate for the TAR that endured perioperative complication was 96.70% (95% CI 90.28-103.12), and for the uncomplicated TAR 87.50% (95% CI 77.12-97.88%) (p = .24). Operating time nor occurrence of perioperative fractures were significantly associated with long-term survival (p = .11 and 0.26, respectively). However, moving average method revealed a significant decreasing trend with a cut-off value of 33 procedures regarding the marginal probability of perioperative osseous complications (p < .01). In conclusion, surgeons should note a learning curve when adapting arthroplasty procedures. After the prosthesis design switch, the learning curve regarding perioperative osseous complications was confirmed at 33 TAR. The switch did not affect long-term survival.
Collapse
Affiliation(s)
- Laurian J M van Es
- Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, The Netherlands; Department of Orthopedic Surgery and Sports Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
| | - Inger N Sierevelt
- Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, The Netherlands; Department of Orthopedic Surgery, Spaarne Gasthuis Academy, Hoofddorp, The Netherlands
| | - Gino M M J Kerkhoffs
- Department of Orthopedic Surgery and Sports Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands; Program Sports and Musculoskeletal Health, Amsterdam Movement Sciences, Amsterdam, The Netherlands; Academic Center for Evidence-Based Sports Medicine, Amsterdam, The Netherlands; Amsterdam Collaboration on Health and Safety in Sports, International Olympic Committee Research Centers, Amsterdam, The Netherlands
| | - Daniel Haverkamp
- Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, The Netherlands
| |
Collapse
|
3
|
Teasdall RJ, Vesely BD, Wood TR, Kipp JA, Lynch KA, Rosas S, Scott AT. Total Ankle Arthroplasty Templating: Preoperative Computer Templating Correlates Highly with Intraoperative Component Selection. J Foot Ankle Surg 2024:S1067-2516(24)00179-0. [PMID: 39168276 DOI: 10.1053/j.jfas.2024.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 05/25/2024] [Accepted: 08/10/2024] [Indexed: 08/23/2024]
Abstract
Proper alignment and sizing are critical to the performance of a successful total ankle arthroplasty. While it is common practice in preoperative planning prior to total knee and total hip arthroplasty, preoperative computer templating has not been well established in the setting of total ankle arthroplasty. A retrospective review of all total ankle arthroplasties performed during a 10-year period by a single fellowship-trained orthopaedic surgeon was conducted. Computer templating was utilized for all preoperative Anterior to Posterior (AP) and lateral standing radiographs, and templated component sizes were compared to the operative reports and postoperative radiographs to determine the precision of the available templates. Statistical analysis was performed with Interclass Correlation Coefficients (ICC) and descriptive statistical tests. Seventy patients with a mean age of 64.8 years (range, 48-87) and mean BMI of 30.34 (range, 19.1-55.6) were included. The ICC demonstrated that both the AP (ICC 0.80 - 95% CI 0.679-0.876) and lateral (ICC 0.786 - 95% CI 0.655-0.867) radiographs provided accurate tibial total ankle arthroplasty component templating. Similarly, the AP (ICC 0.842 - 95% CI 0.745-0.902) and lateral (ICC 0.809 - 95% CI 0.692-0.881) radiographs provided accurate talar templating. No differences were observed when comparing AP to lateral radiographs in percentage of correct component templating: tibial AP 61.4% vs lateral 58.6%, p = .119 and talar component AP 57.1% vs lateral 45.7%, p = .176. These study findings demonstrate that preoperative templating for total ankle arthroplasties is accurate in determining appropriate implant sizing. Accurate templating is an absolute necessity for future templating studies.
Collapse
Affiliation(s)
- Robert J Teasdall
- Department of Orthopaedic Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC
| | - Bryanna D Vesely
- Department of Orthopaedic Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC
| | - Taylor R Wood
- Department of Orthopaedic Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC
| | - Jennifer A Kipp
- Department of Orthopaedic Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC.
| | - Kyle A Lynch
- Department of Orthopaedic Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC
| | - Samuel Rosas
- Department of Orthopaedic Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC
| | - Aaron T Scott
- Department of Orthopaedic Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC
| |
Collapse
|
4
|
Arceri A, Abdi P, Mazzotti A, Zielli SO, Artioli E, Langone L, Sgubbi F, Faldini C. Standard Total Ankle Arthroplasty vs. Patient-Specific Instrumentation: A Comparative Study. J Pers Med 2024; 14:770. [PMID: 39064024 PMCID: PMC11278035 DOI: 10.3390/jpm14070770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 07/06/2024] [Accepted: 07/13/2024] [Indexed: 07/28/2024] Open
Abstract
PURPOSE This retrospective study aims to compare surgical outcomes between two cohorts of patients who underwent total ankle arthroplasty (TAA) using either standard technique or patient-specific instrumentation (PSI). METHODS A consecutive series of patients who affected of end-staged ankle osteoarthritis were retrospectively assessed and divided into two groups based on TAA techniques: a TAA standard technique group and a TAA-using PSI group. The two groups were compared in terms of operative time, additional procedures, complications (neurovascular and wound problems, infection, loosening and osteolysis, revision and explantation rates, and perioperative fracture), clinical scores, and range of motion (ROM). RESULT Fifty-one patients underwent standard TAA, while 13 patients underwent TAA with PSI. At 1-year follow-up, there were no significant differences in complication rates between the two groups (p > 0.05). AOFAS scores were similar, with the standard TAA group scoring 83.33 ± 7.55 and the PSI group scoring 82.92 ± 9.7 (p = 0.870). Likewise, the postoperative ROM did not differ significantly, with 15.12 ± 7.6 degrees for the standard TAA group and 16.05 ± 6.7 degrees for the PSI group (p = 0.689). However, the standard TAA group experienced significantly longer operative time (107.1 ± 22.1 min) compared to the PSI group (91.92 ± 22.9 min, p = 0.032). Additionally, the standard TAA group required more adjunctive procedures (29.7%) compared to the PSI group (7.7%, p = 0.04). Residual pain was also more frequently reported in the standard TAA group (62.7%) than in the PSI group (30.7%, p = 0.038). CONCLUSION While both techniques resulted in comparable complication rates, clinical scores and ROM, the PSI group reported significantly shorter operative time and less residual pain, thus requiring fewer postoperative procedures.
Collapse
Affiliation(s)
- Alberto Arceri
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Pejman Abdi
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Antonio Mazzotti
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
- Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy
| | - Simone Ottavio Zielli
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Elena Artioli
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Laura Langone
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Federico Sgubbi
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Cesare Faldini
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
- Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy
| |
Collapse
|
5
|
Etges APBDS, Jones P, Liu H, Zhang X, Haas D. Improvements in technology and the expanding role of time-driven, activity-based costing to increase value in healthcare provider organizations: a literature review. Front Pharmacol 2024; 15:1345842. [PMID: 38841371 PMCID: PMC11151087 DOI: 10.3389/fphar.2024.1345842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 04/19/2024] [Indexed: 06/07/2024] Open
Abstract
Objective This study evaluated the influence of technology on accurately measuring costs using time-driven activity-based costing (TDABC) in healthcare provider organizations by identifying the most recent scientific evidence of how it contributed to increasing the value of surgical care. Methods This is a literature-based analysis that mainly used two data sources: first, the most recent systematic reviews that specifically evaluated TDABC studies in the surgical field and, second, all articles that mentioned the use of CareMeasurement (CM) software to implement TDABC, which started to be published after the publication of the systematic review. The articles from the systematic review were grouped as manually performed TDABC, while those using CM were grouped as technology-based studies of TDABC implementations. The analyses focused on evaluating the impact of using technology to apply TDABC. A general description was followed by three levels of information extraction: the number of cases included, the number of articles published per year, and the contributions of TDABC to achieve cost savings and other improvements. Results Fourteen studies using real-world patient-level data to evaluate costs comprised the manual group of studies. Thirteen studies that reported the use of CM comprised the technology-based group of articles. In the manual studies, the average number of cases included per study was 160, while in the technology-based studies, the average number of cases included was 4,767. Technology-based studies, on average, have a more comprehensive impact than manual ones in providing accurate cost information from larger samples. Conclusion TDABC studies supported by technologies such as CM register more cases, identify cost-saving opportunities, and are frequently used to support reimbursement strategies based on value. The findings suggest that using TDABC with the support of technology can increase healthcare value.
Collapse
Affiliation(s)
- Ana Paula Beck Da Silva Etges
- PEV Healthcare Consulting, São Paulo, Brazil
- Avant-garde Health, Boston, MA, United States
- Programa de Pós-graduação em Epidemiologia da Escola de Medicina da Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
| | | | - Harry Liu
- Avant-garde Health, Boston, MA, United States
| | | | - Derek Haas
- Avant-garde Health, Boston, MA, United States
| |
Collapse
|
6
|
Mehraban N, Lew AR, Foran IM, Lee S, Bohl DD, Hamid KS. Lateral Locking Plate Fixation of Simple Weber B Fibula Fractures Without a Lag Screw Yields Excellent Radiographic Results. Foot Ankle Spec 2024; 17:131-136. [PMID: 34747245 DOI: 10.1177/19386400211055280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The most common first-line fixation technique for simple Weber B fibula fractures is a lag screw with lateral neutralization plate. The most common surgical technique for unstable Weber B fibula fracture is one-third semi-tubular plate and cortical screws, implemented with lag screw when appropriate. However, the lag technique can be technically challenging in osteoporotic bone or within fibulas of smaller diameter, and in some cases can result in fragmentation at the fracture site, malreduction, or peroneal irritation. The purpose of this study is to examine an alternative first-line method for routine treatment of simple Weber B fibula fractures. METHODS Fifty-two consecutive patients undergoing open reduction internal fixation (ORIF) of a Weber B fibula fracture by a single surgeon were included in this retrospective study. After reduction, a lateral locking plate was applied with cortical screws proximally and locking screws distally. No screw crossed the fracture in any case. Per published precedent, nonunion was defined as either a gap of >3 mm between fracture surfaces >6 months postoperatively or a fracture line >2 to 3 mm wide and sclerosing of the fracture surfaces. Similarly, malunion was defined as one or more of the following: talar tilt >2º, talar subluxation >2 mm, or tibiofibular clear space ≥5 mm. RESULTS The mean (± standard deviation) age of the 52 included patients was 44.2 ± 16.2 years, the mean body mass index was 27.7 ± 6.6 kg/m2, and 63.5% of patients identified themselves as female sex. The mean follow-up was 6.2 (range: 1.5-15) months. In addition to undergoing fixation of the lateral malleolus, 21 patients also underwent fixation of the posterior malleolus, 27 underwent fixation of the medial malleolus, 29 underwent fixation across the syndesmosis, and 7 underwent repair of the deltoid. In all patients, bony anatomic union of the fibula and congruence of the mortise were achieved with no cases of malunion or nonunion. CONCLUSIONS The Arbeitsgemeinschaft für Osteosynthesefragen (AO) fixation technique for simple Weber B fractures with a lag screw and lateral neutralization plating has provided good outcomes for decades. We present an alternative technique for ORIF of these fractures with a lateral locking plate and no lag screw. In our series, we evaluated radiographic union and alignment as our primary outcome measures and found no cases of nonunion or malunion. Prospective cohort testing of lateral locking plates versus traditional fixation in the context of patient-centered value is warranted.Level of Evidence: Level III.
Collapse
Affiliation(s)
- Nasima Mehraban
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois (NM, ARL, IMF, SL, DDB, KSH)
| | - Alexandra R Lew
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois (NM, ARL, IMF, SL, DDB, KSH)
| | - Ian M Foran
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois (NM, ARL, IMF, SL, DDB, KSH)
| | - Simon Lee
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois (NM, ARL, IMF, SL, DDB, KSH)
| | - Daniel D Bohl
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois (NM, ARL, IMF, SL, DDB, KSH)
| | - Kamran S Hamid
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois (NM, ARL, IMF, SL, DDB, KSH)
| |
Collapse
|
7
|
Yau J, Emmerson B, Kakwani R, Murty AN, Townshend DN. Patient-Reported Outcomes in Total Ankle Arthroplasty: Patient Specific Versus Standard Instrumentation. Foot Ankle Spec 2024; 17:30S-37S. [PMID: 37350251 PMCID: PMC11016196 DOI: 10.1177/19386400231179124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/24/2023]
Abstract
BACKGROUND Total ankle arthroplasty (TAA) can now be performed using patient-specific instrumentation (PSI). Advantages include the ability to preoperatively plan and reduce the number of intraoperative surgical steps. The aim of this study was to compare PSI with standard instrumentation (SI) in a nonrandomized retrospective cohort study with respect to patient-reported outcome measures (PROMs). Secondary aims were to compare complications, reoperations, tourniquet time, fluoroscopy time, and postoperative alignment. METHODS In all, 159 patients (111 men, 48 women) undergoing a total of 168 Infinity TAA (Stryker, Memphis, TN) using PSI (Prophecy, Stryker, Memphis, TN) or SI between 2014 and 2021 were included with a minimum follow-up of 12 months. The PROMs were obtained preoperatively and at 1 year, and included the Manchester-Oxford Foot Questionnaire (MOXFQ), Ankle Osteoarthritis Scale (AOS), and European Quality of Life 5 Dimension 3 Level (EQ-5D-3L). Coronal plane deformity correction was assessed using the midline tibiotalar angle (MTTA). Demographics, tourniquet time, and intraoperative fluoroscopy times were obtained from the hospital records. RESULTS There were 61 TAAs in the PSI group and 107 TAAs in the SI group. There was no significant difference in total MOXFQ, AOS, or EQ-5D. There was a significantly reduced tourniquet time (PSI mean: 95.39 minutes, SI mean: 116.87 minutes, P < .001) and radiation exposure (PSI mean: 31 seconds, SI mean: 53 seconds, P < .001). Angular correction was more accurate in the PSI group (PSI mean: 1.29°, SI mean: 2.26°, P = .005). CONCLUSION This study supports the use of PSI to decrease operative time, reduce intraoperative fluoroscopy, improve accuracy of implantation, and improve postoperative alignment in TAA. There was a significant difference (P = .032) in favor of PSI in the walking/standing domain of the MOXFQ at 12 months but no significant difference in overall PROMs. LEVELS OF EVIDENCE Level III, Retrospective.
Collapse
Affiliation(s)
- James Yau
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK
| | | | - Rajesh Kakwani
- Northumbria Healthcare NHS Foundation Trust, North Shields, UK
| | | | - David N. Townshend
- Northumbria Healthcare NHS Foundation Trust, North Shields, UK
- University of Newcastle upon Tyne, Newcastle upon Tyne, UK
| |
Collapse
|
8
|
Iachecen F, Dallagassa MR, Portela Santos EA, Carvalho DR, Ioshii SO. Is it possible to automate the discovery of process maps for the time-driven activity-based costing method? A systematic review. BMC Health Serv Res 2023; 23:1408. [PMID: 38093275 PMCID: PMC10720189 DOI: 10.1186/s12913-023-10411-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 11/30/2023] [Indexed: 12/17/2023] Open
Abstract
OBJECTIVES The main objective of this manuscript was to identify the methods used to create process maps for care pathways that utilized the time-driven activity-based costing method. METHODS This is a systematic mapping review. Searches were performed in the Embase, PubMed, CINAHL, Scopus, and Web of Science electronic literature databases from 2004 to September 25, 2022. The included studies reported practical cases from healthcare institutions in all medical fields as long as the time-driven activity-based costing method was employed. We used the time-driven activity-based costing method and analyzed the created process maps and a qualitative approach to identify the main fields. RESULTS A total of 412 studies were retrieved, and 70 articles were included. Most of the articles are related to the fields of orthopedics and childbirth-related to hospital surgical procedures. We also identified various studies in the field of oncology and telemedicine services. The main methods for creating the process maps were direct observational practices, complemented by the involvement of multidisciplinary teams through surveys and interviews. Only 33% of the studies used hospital documents or healthcare data records to integrate with the process maps, and in 67% of the studies, the created maps were not validated by specialists. CONCLUSIONS The application of process mining techniques effectively automates models generated through clinical pathways. They are applied to the time-driven activity-based costing method, making the process more agile and contributing to the visualization of high degrees of variations encountered in processes, thereby making it possible to enhance and achieve continual improvements in processes.
Collapse
Affiliation(s)
- Franciele Iachecen
- Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná., 1155, Imaculada Conceição st., Curitiba, Paraná, 80215-90, Brazil.
| | - Marcelo Rosano Dallagassa
- Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná., 1155, Imaculada Conceição st., Curitiba, Paraná, 80215-90, Brazil
| | | | - Deborah Ribeiro Carvalho
- Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná., 1155, Imaculada Conceição st., Curitiba, Paraná, 80215-90, Brazil
| | - Sérgio Ossamu Ioshii
- Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná., 1155, Imaculada Conceição st., Curitiba, Paraná, 80215-90, Brazil
| |
Collapse
|
9
|
Mathieu J, Dagneaux L. Midfoot Tarsectomy in Cavovarus: Why PSI Makes a Difference? Foot Ankle Clin 2023; 28:791-803. [PMID: 37863535 DOI: 10.1016/j.fcl.2023.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2023]
Abstract
The cavovarus foot is a complex deformity that can be treated using multiple surgical procedures, ranging from soft tissue surgery to triple arthrodesis. Among these options, anterior midfoot tarsectomy is a three-dimensional closed-wedge osteotomy, traditionally performed slowly and progressively in a blind fashion, and remaining a challenge for unexperimented surgeons with variable outcomes. As such, we investigated and discussed the use of patient-specific cutting guides (PSCGs) in computer-assisted anterior midfoot tarsectomy in terms of accuracy, reproducibility, and safety.
Collapse
Affiliation(s)
- Julie Mathieu
- Department of Orthopedic Surgery, Lower Limb Surgery Unit, Univ Montpellier, 371 av. Gaston Giraud, Montpellier Cedex 05 34295, France
| | - Louis Dagneaux
- Department of Orthopedic Surgery, Lower Limb Surgery Unit, Univ Montpellier, 371 av. Gaston Giraud, Montpellier Cedex 05 34295, France; Laboratoire de mécanique et génie civil (LMGC), CNRS, Montpellier University of Excellence (MUSE), 860, rue de St-Priest, Montpellier 34090, France.
| |
Collapse
|
10
|
April PM, Locke E, Champagne PH, Angers M, Martinez-Gomez AP, Seidel A, Jibri Z, Lalonde KA, Meulenkamp B. Accuracy of a Patient-Specific Total Ankle Arthroplasty Instrumentation. Foot Ankle Int 2023; 44:1150-1157. [PMID: 37727986 DOI: 10.1177/10711007231194049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
BACKGROUND Total ankle arthroplasty (TAA) is a preferred surgical option for end-stage ankle osteoarthritis; however, it is a demanding procedure with a higher historical rate of revision compared with ankle fusion. Patient-specific instrumentation (PSI) has been introduced to optimize prosthesis alignment and theoretically overall improve TAA outcomes. The goal of this study is to report on the experience and surgical outcomes of one implant with specific evaluation of the accuracy and reproducibility of the system with respect to prosthesis alignment and prediction of implant size. METHODS A retrospective, multicentered study involving 4 foot and ankle fellowship-trained orthopaedic surgeon's patients undergoing TAA between January 1, 2015, and December 31, 2018, using the PROPHECY PSI system. RESULTS 80 TAA procedures were performed. On average the postoperative tibial component alignment was 89.9 (range, 86.1-96.5) degrees in the coronal plane, with a mean sagittal alignment of 88.1 (range, 81.3-96.7) degrees. The mean deviation from neutral sagittal alignment improved from 4.9 ± 3.9 degrees preoperatively to 2.7 ± 1.7 degrees postoperatively, whereas the mean coronal alignment improved from 3.3 ± 2.5 degrees to 1.3 ± 1.1 degrees. The PSI software correctly determined the tibial implant size in 70 patients (89%). Prediction of talar implant sizing was less accurate than the tibial component, with 56 patients (71%) using the predicted sized implant. The overall implant survival at a mean follow-up of 45 months (range, 27-76) was 97.5%. CONCLUSION We found that this PSI system accurately and reliably assisted in implant total ankle prosthesis positioning within a clinically acceptable margin and without significant outliers. Prediction of implant size was not as accurate as component orientation. LEVEL OF EVIDENCE Level III, retrospective study.
Collapse
Affiliation(s)
| | - Eric Locke
- Department of Orthopaedics, Civic Hospital, Ottawa, Canada
| | | | | | | | - Angela Seidel
- Department of Orthopaedics, Civic Hospital, Ottawa, Canada
| | - Zaid Jibri
- Department of Orthopaedics, Civic Hospital, Ottawa, Canada
| | | | | |
Collapse
|
11
|
Biela G, Piraino J, Roukis TS. An Analysis of 50 Consecutive Total Ankle Replacements Undergoing Preoperative Computerized Tomography Scan-Based, Engineer-Provided Planning From a Single Noninventor, Nonconsultant Surgeon. J Foot Ankle Surg 2023; 62:228-236. [PMID: 35871115 DOI: 10.1053/j.jfas.2022.06.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 06/14/2022] [Accepted: 06/23/2022] [Indexed: 02/03/2023]
Abstract
Preoperative computerized tomography (CT) scan-based, engineer-provided alignment plans and patient-specific pinning blocks for total ankle replacement (TAR) are available for use in the United States. However, nonbiased studies that justify the additional expense associated with this technology through support of the marketed benefits of less procedural complexity, less intraoperative radiation and reduced surgical time, are lacking. Therefore, to verify the manufacturer's proposed benefits, we sought to investigate our experience with this preoperative CT scan-based, engineer-provided plan and patient-specific pinning blocks during primary TAR. In review of our 50 TAR patients, we found that "perfect" radiographic alignment was not consistently achieved and the accuracy of component prediction was modest. Furthermore, the preoperative plans and patient-specific pinning blocks did not simplify the complexity of our operations since the operative time, intraoperative image intensification time and radiation dose per case all exceeded published historical TAR controls. Interestingly, we identified a significant difference in placement accuracy between the arced and flat-top talar component types that were implanted with the arced being more frequently malaligned. We did not find associations between preoperative deformity severity and accuracy of postoperative alignment. These findings suggest that it is imperative to have surgeons continue to rely on their own surgical planning and experience to achieve optimum radiographic alignment rather than depending on engineer-based recommendations or "surface matched" pinning blocks. Ultimately, we were unable to support the purported benefits of this CT scan-based, engineer-provided alignment plan and patient-specific pinning blocks for this manufacturer's primary TAR systems.
Collapse
Affiliation(s)
- Garrett Biela
- Post-Graduate Year 2 Resident, Department of Orthopaedic Surgery & Rehabilitation, Foot & Ankle Service Line, University of Florida College of Medicine-Jacksonville, Jacksonville, FL.
| | - Jason Piraino
- Associate Professor, Department of Orthopaedic Surgery & Rehabilitation, Chairman, Foot & Ankle Service Line, University of Florida College of Medicine-Jacksonville, Jacksonville, FL
| | - Thomas S Roukis
- Professor, Department of Orthopaedic Surgery & Rehabilitation, Foot & Ankle Service Line, University of Florida College of Medicine-Jacksonville, Jacksonville, FL
| |
Collapse
|
12
|
Hinh CM, Chong ACM, Bierman BR, Uglem TP. Computed Tomography Derived Patient-specific Instrumentation Total Ankle Arthroplasty Survivorship Outcomes. J Foot Ankle Surg 2023; 62:338-346. [PMID: 36180364 DOI: 10.1053/j.jfas.2022.08.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/19/2022] [Accepted: 08/27/2022] [Indexed: 02/03/2023]
Abstract
Computed tomography (CT) derived patient-specific total ankle arthroplasty (TAA) systems have been utilized for improved accuracy and reproducible implant alignment. The purpose of the present study was to report the overall implant survivorship as well as radiographic analysis of patients who underwent primary TAA utilizing CT-derived patient-specific instrumentation. A retrospective review of medical charts and radiographs were performed on patients who had undergone primary TAA at a single institution in the Midwest region from March 2013 to October 2020. Radiographic analysis included preoperative, initial postoperative, and final follow-up coronal and sagittal tibiotalar alignment as well as periprosthetic radiolucency. A total of 96 patients with a mean follow-up of 3 years (range, 0.3-7.3 years) were included. Implant survivorship was found to be 92% at median follow-up of 3 years. A total of 8 cases (8.3%) required revision/reoperation, with 6 (6.3%) of these reoperations directly related for failure of one of the metallic implant components. There was significant improvement in both coronal and sagittal tibiotalar alignment from preoperative to initial postoperative follow-up (p < .001). At latest postoperative follow-up, there were 88% of TAAs that remained in a neutral alignment following surgery. A total of 10 cases were found to have radiolucency at latest follow-up. In conclusion, the use of CT derived patient-specific TAA showed high implant survivorship with significant improvement of sagittal and coronal tibiotalar alignment. With better implant alignment and position, it potentially reduces the risk of early implant failure or implant loosening in long-term follow-up.
Collapse
Affiliation(s)
- Christopher M Hinh
- Sanford Health Podiatric Medicine and Surgery Residency, Sanford Orthopedics and Sports Medicine, Fargo, ND
| | - Alexander C M Chong
- Sanford Health Podiatric Medicine and Surgery Residency, Sanford Orthopedics and Sports Medicine, Fargo, ND; Department of Graduate Medical Education - Sanford Health, Fargo, ND.
| | - Bennen R Bierman
- Sanford Health Podiatric Medicine and Surgery Residency, Sanford Orthopedics and Sports Medicine, Fargo, ND
| | - Timothy P Uglem
- Sanford Health Podiatric Medicine and Surgery Residency, Sanford Orthopedics and Sports Medicine, Fargo, ND
| |
Collapse
|
13
|
Benignus C, Buschner P, Meier MK, Wilken F, Rieger J, Beckmann J. Patient Specific Instruments and Patient Individual Implants—A Narrative Review. J Pers Med 2023; 13:jpm13030426. [PMID: 36983609 PMCID: PMC10051718 DOI: 10.3390/jpm13030426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/20/2023] [Accepted: 02/25/2023] [Indexed: 03/02/2023] Open
Abstract
Joint arthroplasties are one of the most frequently performed standard operations worldwide. Patient individual instruments and patient individual implants represent an innovation that must prove its usefulness in further studies. However, promising results are emerging. Those implants seem to be a benefit especially in revision situations. Most experience is available in the field of knee and hip arthroplasty. Patient-specific instruments for the shoulder and upper ankle are much less common. Patient individual implants combine individual cutting blocks and implants, while patient individual instruments solely use individual cutting blocks in combination with off-the-shelf implants. This review summarizes the current data regarding the implantation of individual implants and the use of individual instruments.
Collapse
Affiliation(s)
- Christian Benignus
- Department of Traumatology and Orthopedic Surgery, Hospital Ludwigsburg, Posilipostr. 4, 71640 Ludwigsburg, Germany
| | - Peter Buschner
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Malin Kristin Meier
- Department of Orthopedic Surgery and Traumatology, Inselspital, University Hospital Bern, University of Bern, Freiburgstr. 4, 3010 Bern, Switzerland
| | - Frauke Wilken
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Johannes Rieger
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Johannes Beckmann
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
- Correspondence:
| |
Collapse
|
14
|
Wang J, Wang X, Sun B, Yuan L, Zhang K, Yang B. 3D-printed patient-specific instrumentation decreases the variability of patellar height in total knee arthroplasty. Front Surg 2023; 9:954517. [PMID: 36704513 PMCID: PMC9871753 DOI: 10.3389/fsurg.2022.954517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 12/16/2022] [Indexed: 01/11/2023] Open
Abstract
Objective Three-dimensionally (3D) printed patient-specific instrumentation (PSI) might help in this regard with individual design and more accurate osteotomy, but whether the utility of such instrumentations minimizes the variability of patellar height in total knee arthroplasty (TKA) and the reasons for this effect are unknown. Our aim is to compare and analyze the variability of patellar height with PSI and conventional instrumentation (CI) in TKA. Methods Between March 2018 and November 2021, 215 patients with severe knee osteoarthritis who were treated with primary unilateral TKA were identified for this observational study. The patients were divided into the CI-TKA group and PSI-TKA group according to the osteotomy tools used in TKA. Preoperative and postoperative radiographic parameters including hip-knee-ankle angle (HKA), posterior tibial slope (PTS), Insall-Salvati ratio, modified Caton-Deschamps (mCD) ratio, anterior condylar offset (ACO), and posterior condylar offset (PCO) were evaluated. Results The groups were similar in patients' demographic data, clinical scores, and radiographic parameters preoperatively. Overall, according to the results of the Insall-Salvati ratio, postoperative patellar height reduction was noted in 140 patients (65.1%). Interestingly, the variability of patellar height was smaller in the PSI-TKA group. Radiographic evaluation revealed that the Insall-Salvati ratio after TKA had a minor change in the PSI-TKA group (p = 0.005). Similarly, the mCD ratio after TKA also had a minor change in the PSI-TKA group (p < 0.001). Compared to those in the CI-TKA group, the ACO (p < 0.001) and PCO (p = 0.011) after TKA had a minor change in the PSI-TKA group, but no minor PTS change (p = 0.951) was achieved in the PSI-TKA group after TKA. However, even with 3D-printed patient-specific instrumentation, there were still significant reductions in patellar height, ACO, PCO, and PTS after TKA (p < 0.001). Conclusion The variability of patellar height was sufficiently minimized with more accurate anterior and posterior femoral condyle osteotomy when 3D printed PSI was used. Furthermore, there was a trend in over-resection of the femoral anterior and posterior condyle and a marked reduction in PTS during TKA, which could lead to a change in patellar height and might result in more patellofemoral complications following TKA. Level of evidence Level II.
Collapse
|
15
|
Stauffer TP, Kim BI, Grant C, Adams SB, Anastasio AT. Robotic Technology in Foot and Ankle Surgery: A Comprehensive Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:686. [PMID: 36679483 PMCID: PMC9864483 DOI: 10.3390/s23020686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/11/2022] [Accepted: 12/30/2022] [Indexed: 06/17/2023]
Abstract
Recent developments in robotic technologies in the field of orthopaedic surgery have largely been focused on higher volume arthroplasty procedures, with a paucity of attention paid to robotic potential for foot and ankle surgery. The aim of this paper is to summarize past and present developments foot and ankle robotics and describe outcomes associated with these interventions, with specific emphasis on the following topics: translational and preclinical utilization of robotics, deep learning and artificial intelligence modeling in foot and ankle, current applications for robotics in foot and ankle surgery, and therapeutic and orthotic-related utilizations of robotics related to the foot and ankle. Herein, we describe numerous recent robotic advancements across foot and ankle surgery, geared towards optimizing intra-operative performance, improving detection of foot and ankle pathology, understanding ankle kinematics, and rehabilitating post-surgically. Future research should work to incorporate robotics specifically into surgical procedures as other specialties within orthopaedics have done, and to further individualize machinery to patients, with the ultimate goal to improve perioperative and post-operative outcomes.
Collapse
Affiliation(s)
| | - Billy I. Kim
- School of Medicine, Duke University, Durham, NC 27710, USA
| | - Caitlin Grant
- School of Medicine, Duke University, Durham, NC 27710, USA
| | - Samuel B. Adams
- Departmen of Orthopaedic Surgery, Duke University, Durham, NC 27710, USA
| | | |
Collapse
|
16
|
Heisler L, Vach W, Katz G, Egelhof T, Knupp M. Patient-Specific Instrumentation vs Standard Referencing in Total Ankle Arthroplasty: A Comparison of the Radiologic Outcome. Foot Ankle Int 2022; 43:741-749. [PMID: 35209725 PMCID: PMC9168897 DOI: 10.1177/10711007221077100] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Existing literature on the superiority of patient-specific instrumentation (PSI) in total ankle arthroplasty (TAA) over standard referencing (SR) is limited. Advantages presented include better implant alignment, shorter operating times, and increased accuracy of implant size prediction. The aim of this retrospective study was to analyze PSI in the hands of an experienced foot and ankle surgeon new to both PSI and SR for this specific implant, in regard to determining implant alignment, operative times, and radiologic short-term outcome and predicting implant size for tibial and talar components. METHODS Twenty-four patients undergoing TAA using PSI were compared to 25 patients using SR instrumentation. Outcome measures included alignment of the tibial component (α coronal plane, γ sagittal plane), the tibiotalar tilt (β), and the talar offset x on the sagittal view as well as the presence of radiolucent lines, operation time, and wound healing. Postoperative outcome was assessed at 6 weeks, 4 months, and 1 year postoperatively. RESULTS Implant positioning was similar in both groups, and no advantage in regard to the operative time could be seen when comparing TAA using PSI to SR. Implant size prediction was more reliable for the tibia than for the talus. Three patients (1 from the SR group and 2 from the PSI group) showed radiolucent lines around the tibial component. Two patients (both SR group) suffered delayed wound healing, albeit not requiring any additional measures. CONCLUSION The PSI method did not show an advantage over SR in regard to positioning of the components or the duration of the surgery. The current study suggests that no initial advantage of PSI over SR are to be expected in standard total ankle replacement. LEVEL OF EVIDENCE Level III, retrospective study.
Collapse
Affiliation(s)
| | - Werner Vach
- Basel Academy for Quality and Research
in Medicine, Basel, Switzerland
| | - Georg Katz
- Merian Iselin Klinik, Institute for
Radiology, Basel, Switzerland
| | - Thomas Egelhof
- Merian Iselin Klinik, Institute for
Radiology, Basel, Switzerland
| | - Markus Knupp
- University of Basel, Basel,
Switzerland,Orthopedic Surgery & Traumatology,
Mein Fusszentrum AG, Basel, Switzerland,Markus Knupp, MD, Specialist in Orthopedic
Surgery & Traumatology, Mein Fusszentrum AG, Eichenstrasse 31, Basel CH
4054, Switzerland.
| |
Collapse
|
17
|
Advances in the Application of Three-dimensional Printing for the Clinical Treatment of Osteoarticular Defects. Curr Med Sci 2022; 42:467-473. [PMID: 35451806 DOI: 10.1007/s11596-022-2565-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 10/26/2021] [Indexed: 11/03/2022]
Abstract
As a promising manufacturing technology, three-dimensional (3D) printing technology is widely used in the medical field. In the treatment of osteoarticular defects, the emergence of 3D printing technology provides a new option for the reconstruction of functional articular surfaces. At present, 3D printing technology has been used in clinical applications such as models, patient-specific instruments (PSIs), and customized implants to treat joint defects caused by trauma, sports injury, and tumors. This review summarizes the application status of 3D printing technology in the treatment of osteoarticular defects and discusses its advantages, disadvantages, and possible future research strategies.
Collapse
|
18
|
Fram B, Corr DO, Rogero RG, Pedowitz DI, Tsai J. Short-Term Complications and Outcomes of the Cadence Total Ankle Arthroplasty. Foot Ankle Int 2022; 43:371-377. [PMID: 34549617 DOI: 10.1177/10711007211043853] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Total ankle arthroplasty (TAA) is an increasingly popular option for the operative treatment of ankle arthritis. The Cadence TAA entered clinical use in 2016 and was designed to address common failure modes of prior systems. We report early complications and radiographic and clinical outcomes of this total ankle system at a minimum of 2 years of follow-up. METHODS We performed a retrospective review of a consecutive cohort of patients undergoing primary Cadence TAA by a single surgeon from 2016 to 2017. Complications and reoperations were documented using the American Orthopaedic Foot & Ankle Society (AOFAS) TAA reoperation coding system. Patients completed the Foot and Ankle Ability Measure (FAAM) Activities of Daily Living (ADL) and Sport subscales, SF-12 Mental (MCS) and Physical (PCS) Component Summaries, and visual analog scale (VAS) pain rating (0-100). Radiographic evaluation was performed to assess postoperative range of motion (ROM) of the sole of the foot relative to the long axis of the tibia, alignment, and implant complications. RESULTS Fifty-eight patients with a mean age of 63.3 years and mean body mass index of 31.9 kg/m2 were included. Twelve of 58 patients (20.7%) underwent an additional procedure(s) within 2 years, including 3 (5.2%) who required removal of one or both components, 2 for infection and 1 for osteolysis. Forty-three patients were followed for a minimum of 2 years with radiographic imaging; 1 patient's (2.3%) radiographs had signs of peri-implant osteolysis, with no cases demonstrating loosening or subsidence. FAAM-ADL, FAAM-Sport, SF-12 PCS, and VAS pain scores all improved at a mean of 27.4 months postoperatively, with mean score changes (± SD) of 16.3 (± 22.0), 25.3 (± 24.5), 6.0 (± 11.1), and -32.3 (± 39.8), respectively. Radiographic analysis revealed that average coronal alignment improved from 6.9 degrees from neutral preoperatively to 2.3 degrees postoperatively. The average ROM of the foot relative to the tibia was 36.5 degrees total arc of motion based on lateral radiographs. CONCLUSION Early experience with this 2-component total ankle replacement was associated with a high component retention rate, improved coronal plane alignment, good postoperative ROM, radiographically stable implants, and improved patient function. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
- Brianna Fram
- Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | - Daniel O Corr
- Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | - Ryan G Rogero
- Rothman Orthopaedic Institute, Philadelphia, PA, USA.,University of Tennessee Campbell Clinic Orthopaedics, Germantown, TN, USA
| | | | - Justin Tsai
- Rothman Orthopaedic Institute, Philadelphia, PA, USA
| |
Collapse
|
19
|
Doyle MD, Ishibashi MA, Sherick RM, Mitchell LH, Castellucci-Garza FM, Rao NM. Outcomes and Complications of the INFINITY Total Ankle: A Systematic Review. Foot Ankle Spec 2022:19386400221079491. [PMID: 35189714 DOI: 10.1177/19386400221079491] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Matthew D Doyle
- Silicon Valley Reconstructive Foot and Ankle Fellowship, Palo Alto Medical Foundation, Mountain View, California
| | - Megan A Ishibashi
- Kaiser San Francisco Bay Area Foot and Ankle Residency Program, Kaiser Foundation Hospitals, Oakland, California
| | - Ryan M Sherick
- Silicon Valley Reconstructive Foot and Ankle Fellowship, Palo Alto Medical Foundation, Mountain View, California
| | - Logan H Mitchell
- Kaiser San Francisco Bay Area Foot and Ankle Residency Program, Kaiser Foundation Hospitals, Oakland, California
| | - Francesca M Castellucci-Garza
- Kaiser San Francisco Bay Area Foot and Ankle Residency Program, Department of Orthopedics, Kaiser Foundation Hospitals, Antioch, California
| | - Nilin M Rao
- Silicon Valley Reconstructive Foot and Ankle Fellowship, Palo Alto Medical Foundation, Mountain View, California
| |
Collapse
|
20
|
Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review. INTERNATIONAL ORTHOPAEDICS 2021; 45:2445-2452. [PMID: 34345975 DOI: 10.1007/s00264-021-05145-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Accepted: 07/07/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Patient-specific instrument (PSI) may theoretically make total ankle arthroplasty (TAA) more accurate. Several studies have reported the outcomes of PSI TAA. The aim of this study is to systematically review the literature of PSI TAA. METHODS PubMed, Embase, Web of Science, and Cochrane Library databases were systematically reviewed according to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines for PSI TAA. The quality of the included studies was evaluated according to Methodological Index for Non-Randomized Studies (MINORS). RESULT Nine articles were ultimately included in the systematic review. The implant position and function outcome of TAA was similar between PSI and SI. Prediction accuracy of implant size remained great difference. PSI can shorten the operative time and fluoroscopy time. The quality of current studies on PSI TAA is insufficient to produce high-level evidence. CONCLUSION PSI can get similar implant position and clinical outcome in TAA compared to SI, but current evidence is not strong enough to evaluate PSI TAA.
Collapse
|
21
|
Escudero MI, Le V, Bemenderfer TB, Barahona M, Anderson RB, Davis H, Wing KJ, Penner MJ. Total Ankle Arthroplasty Radiographic Alignment Comparison Between Patient-Specific Instrumentation and Standard Instrumentation. Foot Ankle Int 2021; 42:851-858. [PMID: 33749342 DOI: 10.1177/1071100721996379] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Several benefits are published supporting patient-specific instrumentation (PSI) in total ankle arthroplasty (TAA). This study seeks to determine if TAA with PSI yields different radiographic outcomes vs standard instrumentation (SI). METHODS Sixty-seven primary TAA patients having surgery using PSI or SI between 2013 and 2015 were retrospectively reviewed using weightbearing radiographs at 6-12 weeks postsurgery. Radiographic parameters analyzed were the medial distal tibia angle (MDTA), talar-tilt angle (TTA), anatomic sagittal distal tibia angle (aSDTA), lateral talar station (LTS), and talar component inclination angle (TCI). A comparison of the 2 groups for each radiologic parameter's distribution was performed using a nonparametric median test and Fisher exact test. Furthermore, TAAs with all radiographic measurements within acceptable limits were classified as "perfectly aligned." The rate of "perfectly aligned" TAAs between groups was compared using a Fisher exact test with a significance of .05. RESULTS Of the 67 TAAs, 51 were done with PSI and 16 with SI. There were no differences between groups in MDTA (P = .174), TTA (P = .145), aSDTA (P = .98), LTS (P = .922), or TCI angle (P = .98). When the rate of "perfectly aligned TAA" between the 2 groups were compared, there was no significant difference (P = .35). CONCLUSION No significant radiographic alignment differences were found between PSI and SI implants. This study showed that both techniques achieve reproducible TAA radiographic coronal and sagittal alignment for the tibial component when performed by experienced surgeons. The talar component's sagittal alignment is similar whether or not PSI was used but is noticeably different from normal anatomic alignment by design. LEVEL OF EVIDENCE Level III, retrospective cohort study using prospectively collected data.
Collapse
Affiliation(s)
- Mario I Escudero
- Department of Orthopaedics, University of Chile, Santiago, Chile
| | - Vu Le
- Pacific Orthopaedic Associates, Alhambra, CA, USA
| | | | | | | | - Hodges Davis
- Department of Orthopaedics, OrthoCarolina, Charlotte, NC, USA
| | - Kevin J Wing
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Murray J Penner
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
22
|
Time-Driven Activity-Based Costing Provides a Lower and More Accurate Assessment of Costs in the Field of Orthopaedic Surgery Compared With Traditional Accounting Methods. Arthroscopy 2021; 37:1620-1627. [PMID: 33232748 DOI: 10.1016/j.arthro.2020.11.028] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 11/01/2020] [Accepted: 11/02/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE To analyze the implementation and benefits of time-driven activity-based costing (TDABC) in the field of orthopaedic surgery. METHODS We performed a search of PubMed, Google Scholar, and Embase in March 2020, using the following terms: "Time-Driven Activity-Based Costing," "TDABC," "Orthopaedic Surgery," and "Cost." Then we selected the studies that used the TDABC methodology to generate costs for a particular aspect of orthopaedic surgery. The included studies were divided into the following 5 main categories for ease of analysis: joint arthroplasty, trauma, hand, electronic medical record (EMR) implementation, and pediatric. We analyzed the overall ability of TDABC in the field of orthopaedic surgery, compared to the standard costing methods. RESULTS We included a total of 19 studies that implemented the TDABC methodology to generate a cost, which was compared to traditional accounting methods. The orthopaedic subspecialty with the most amount of TDABC implementation has been the field of joint arthroplasty. In these studies, the authors have noted that TDABC has provided a more granular breakdown of costs and has calculated a lower cost compared with traditional accounting methods. CONCLUSION TDABC is a powerful cost analysis method that has demonstrated benefit over the activity-based costing (ABC) approach in determining a lower and more accurate cost of orthopaedic procedures. Furthermore, the TDABC method generates an average cost reduction of $10,000 and $12,000 for total hip arthroplasty and total knee arthroplasty, respectively. CLINICAL RELEVANCE TDABC can allow health care administration to better determine and understand the cost drivers of particular orthopaedic procedures at their institutions. With improved estimates on the true cost of an activity, hospital administrators and department chairs can adjust to ensure cost-effective, patient-centered health care.
Collapse
|
23
|
Giardini P, Di Benedetto P, Mercurio D, Gisonni R, Molinari M, Causero A, Cortese F. Infinity ankle arthroplasty with traditional instrumentation and PSI prophecy system: preliminary results. ACTA BIO-MEDICA : ATENEI PARMENSIS 2020; 91:e2020021. [PMID: 33559635 PMCID: PMC7944708 DOI: 10.23750/abm.v91i14-s.10989] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 11/30/2020] [Indexed: 02/01/2023]
Abstract
Ankle arthrodesis has been considered the surgical Gold Standard for advanced ankle arthritis; prosthetic replacement of the tibio-talar joint played a secondary role.The introduction of last generation ankle prostheses lead to better outcome and a lower rate of complication. PSI represents the most recent innovations introduced on the market of ankle arthroplasty:PSI is proposed as a surgical technique capable of making ankle arthroplasty more accurate and more reproducible compared to standard referencing guides Aim of the study is to report early clinical and radiographic outcomes obtained from a single surgeon experience by implanting the same ankle prosthesis using a standard (STD) or a PSI instrumentation Unlike no difference in the average increment of normalized sub score related to function in each group (PSI vs STD), the analysis of normalized pain sub score pointed out a greater average improvement in the PSI group(+75%)compared to the STD group(+62%);this result has been adovacated to the absence of post operative gutter impingement syndrome in the PSI group compared to the STD referencing group. The analysis of radiographic angles revealed a more accurate and reproducible positioning of the components in the PSI group; ankle arthroplasty performed with PSI reported a reduction of both surgical times and the need of intraop.fluoroscopy. PSI ankle arthroplasty achived more accurate and reproducible clinical and radiographic results compared to STD instrumentation;long-term follow-up are needed to demonstrate whether a better positioning of the implant is associated with an increased survival of the prosthesis and therefore justifies the additional costs of PSI.
Collapse
Affiliation(s)
| | - Paolo Di Benedetto
- Department of Orthopaedic Surgery, University Hospital of Udine, Udine, Italy.
| | - Domenico Mercurio
- Department of Orthopaedic Surgery, S. Maria della Misericordia Hospital, Rovereto, Italy.
| | - Renato Gisonni
- Department of Orthopaedic Surgery, University Hospital of Udine, Udine, Italy.
| | - Marco Molinari
- Department of Orthopaedic Surgery, Fiemme Hospital, Cavalese, Italy.
| | - Araldo Causero
- Department of Orthopaedic Surgery, University Hospital of Udine, Udine, Italy.
| | - Fabrizio Cortese
- Department of Orthopaedic Surgery, S. Maria della Misericordia Hospital, Rovereto, Italy.
| |
Collapse
|
24
|
A new ligament-compatible patient-specific 3D-printed implant and instrumentation for total ankle arthroplasty: from biomechanical studies to clinical cases. J Orthop Traumatol 2020; 21:16. [PMID: 32876778 PMCID: PMC7468019 DOI: 10.1186/s10195-020-00555-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 07/29/2020] [Indexed: 12/18/2022] Open
Abstract
Background Computer navigation and patient-specific instrumentation for total ankle arthroplasty have still to demonstrate their theoretical ability to improve implant positioning and functional outcomes. The purpose of this paper is to present a new and complete total ankle arthroplasty customization process for severe posttraumatic ankle joint arthritis, consisting of patient-specific 3D-printed implant and instrumentation, starting from a ligament-compatible design. Case presentation The new customization process was proposed in a 57-year-old male patient and involved image analysis, joint modeling, prosthesis design, patient-specific implant and instrumentation development, relevant prototyping, manufacturing, and implantation. Images obtained from a CT scan were processed for a 3D model of the ankle, and the BOX ankle prosthesis (MatOrtho, UK) geometries were customized to best fit the model. Virtual in silico, i.e., at the computer, implantation was performed to optimize positioning of these components. Corresponding patient-specific cutting guides for bone preparation were designed. The obtained models were printed in ABS by additive manufacturing for a final check. Once the planning procedure was approved, the models were sent to final state-of-the-art additive manufacturing (the metal components using cobalt-chromium-molybdenum powders, and the guides using polyamide). The custom-made prosthesis was then implanted using the cutting guides. The design, manufacturing, and implantation procedures were completed successfully and consistently, and final dimensions and location for the implant corresponded with the preoperative plan. Immediate post-op X-rays showed good implant positioning and alignment. After 4 months, clinical scores and functional abilities were excellent. Gait analysis showed satisfactory joint moment at the ankle complex and muscle activation timing within normality. Conclusions The complete customization process for total ankle arthroplasty provided accurate and reliable implant positioning, with satisfactory short-term clinical outcomes. However, further studies are needed to confirm the potential benefits of this complete customization process. Level of evidence 5. Case report.
Collapse
|
25
|
Ke S, Ran T, He Y, Lv M, Song X, Zhou Y, Xu Y, Wang M. Does patient-specific instrumentation increase the risk of notching in the anterior femoral cortex in total knee arthroplasty? A comparative prospective trial. INTERNATIONAL ORTHOPAEDICS 2020; 44:2603-2611. [PMID: 32852600 DOI: 10.1007/s00264-020-04779-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Accepted: 07/02/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE Patient-specific instrumentation (PSI) was usually applied in total knee arthroplasty (TKA) to acquire a favourable alignment. We hypothesized that using PSI had a potential risk of notching in the anterior femoral cortex, because the femoral component may be placed in an overextension position due to the distal femoral sagittal anteversion. The aim of this study was to figure out the relationship between the notch and the distal femoral sagittal anteversion in PSI-assisted TKA. METHODS One hundred thirty-one patients who were to undergo total knee arthroplasty (TKA) were randomly divided into conventional instrumentation (CI) group and PSI group. The computed tomography (CT) data of lower extremities was collected and imported to the Mimics software to reconstruct the three-dimensional (3D) bone image of the femur. The angle between distal femoral anatomic axis (DFAA) and femoral mechanical axis (FMA) on sagittal plane was defined as distal femoral sagittal anteverted angle (DFSAA) and measured. The number of notch intra-operative and post-operative was recorded. Then, we calculated the incidence of the notch and analyzed its relationship with DFSAA. RESULTS The average DFSAA of 262 femurs is 2.5° ± 1.5° (range, 0.0°-5.7°). When DFSAA ≥ 3°, the incidence of notch was 7.10% in CI group and 33.30% in PSI group, respectively, which shows significant statistical difference in the two groups (P = 0.016 < 0.05). When DFSAA < 3°, the incidence of notch was 6.50% in CI group and 5.30% in PSI group, respectively, which shows no significant statistical difference in the two groups (P = 0.667 > 0.05). CONCLUSION DFSAA could be taken as an indicator to predict the notch when performing TKA assisted with PSI. Especially when the DFSAA ≥ 3°, the risk of notch could be markedly increased.
Collapse
Affiliation(s)
- Song Ke
- Department of Orthopaedics, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, China
| | - Tianfei Ran
- Department of Orthopaedics, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, China
| | - Yongqin He
- Department of Orthopaedics, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, China
| | - Mingrui Lv
- Department of Orthopaedics, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, China
| | - Xin Song
- Department of Orthopaedics, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, China
| | - Yuanyuan Zhou
- Department of Orthopaedics, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, China
| | - Yuan Xu
- Department of Orthopaedics, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, China
| | - Min Wang
- Department of Orthopaedics, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, China.
| |
Collapse
|
26
|
Etges APBDS, Ruschel KB, Polanczyk CA, Urman RD. Advances in Value-Based Healthcare by the Application of Time-Driven Activity-Based Costing for Inpatient Management: A Systematic Review. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2020; 23:812-823. [PMID: 32540239 DOI: 10.1016/j.jval.2020.02.004] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 12/31/2019] [Accepted: 02/12/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES Implementation of value-based initiatives depends on cost-assessment methods that can provide high-quality cost information. Time-driven activity-based costing (TDABC) is increasingly being used to solve the cost-information gap. This study aimed to review the use of the TDABC methodology in real-world settings and to estimate its impact on the value-based healthcare concept for inpatient management. METHODS This systematic review was conducted by screening PubMed/MEDLINE and Scopus databases following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, including all studies up to August 2019. The use of TDABC for inpatient management was the main eligibility criterion. A qualitative approach was used to analyze the different methodological aspects of TDABC and its effective contribution to the implementation of value-based initiatives. RESULTS A total of 1066 studies were retrieved, and 26 full-text articles were selected for review. Only studies focused on surgical inpatient conditions were identified. Most of the studies reported the types of activities on a macrolevel. Professional and structural cost variables were usually assessed. Eighteen studies reported that TDABC contributed to value-based initiatives, especially cost-saving findings. TDABC was satisfactorily applied to achieve value-based contributions in all the studies that used the method for this purpose. CONCLUSIONS TDABC could be a strategy for increasing cost accuracy in real-world settings, and the method could help in the transition from fee-for-service to value-based systems. The results could provide a clearer idea of the costs, help with resource allocation and waste reduction, and might support clinicians and managers in increasing value in a more accurate and transparent way.
Collapse
Affiliation(s)
| | - Karen Brasil Ruschel
- National Institute of Science and Technology for Health Technology Assessment, Porto Alegre, Brazil
| | - Carisi Anne Polanczyk
- National Institute of Science and Technology for Health Technology Assessment, Porto Alegre, Brazil; Graduate Program in Cardiology and Cardiovascular Sciences, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil
| | - Richard D Urman
- Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital/Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
27
|
Affiliation(s)
- Louis Dagneaux
- Department of Orthopaedic Surgery, Lower Limb Surgery Unit, Lapeyronie University Hospital, Montpellier, France
| | - François Canovas
- Department of Orthopaedic Surgery, Lower Limb Surgery Unit, Lapeyronie University Hospital, Montpellier, France
| |
Collapse
|
28
|
Escudero MI, Symes M, Bemenderfer TB, Barahona M, Anderson R, Davis H, Wing KJ, Penner MJ. Does Patient-Specific Instrumentation Have a Higher Rate of Early Osteolysis Than Standard Referencing Techniques in Total Ankle Arthroplasty? A Radiographic Analysis. Foot Ankle Spec 2020; 13:32-42. [PMID: 30757922 DOI: 10.1177/1938640019828069] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Introduction: Patient-specific instrumentation (PSI) has been developed for total ankle arthroplasty (TAA), with proven benefits. One concern regarding PSI is the need for more soft tissue dissection in order to accurately position the PSI guides, which has the theoretical disadvantage of increased osteolysis. The purpose of our study is to compare the incidence and magnitude of osteolysis for the INFINITY Total Ankle System between PSI and standard referencing (SR) techniques. Methods: Sixty-seven patients who underwent primary TAA using Prophecy (PSI) or SR technique between 2013 and 2015 were reviewed in a retrospective observational study. Osteolysis was assessed on radiographs at 2 years. The incidence was calculated by binomial distribution. The number of zones compromised and the magnitude of osteolysis was calculated using the median as a summary statistic and interquartile range as dispersion statistic. Fisher exact test was used to compare both groups, then a regression model was estimated to calculate the odds ratio for osteolysis. Results: Of the 67 TAAs, 51 were in the PSI group and 16 in the SR group. In the PSI group the incidence, number of compromised zones (CZ), and magnitude was 41% (25%-59%), 1 [1-2], and 2 [2-3], respectively. In the SR group these were 36% (13%-65%), 3 [2-3], and 3 [2-4], respectively. No significant differences were found (P = .46, P = .12, P = .33). A slightly higher risk of osteolysis was found in the PSI group (odds ratio = 1.33 [0.36-4.83]) (P = .46). The majority of lesions were in 1 zone with size of 2 to 5 mm (63% for all cohort, 64% PSI, 60% SR). Two cases underwent revision for aseptic loosening, 1 in the SR group and 1 in the PSI group. Conclusion: According to our data, there is no significant difference between PSI and SR in terms of risk, incidence, size and magnitude of osteolysis in the INFINITY Total Ankle System at 2 years. Levels of Evidence: Therapeutic, Level III, Retrospective cohort study.
Collapse
Affiliation(s)
- Mario I Escudero
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Michael Symes
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Thomas Bradford Bemenderfer
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Maximiliano Barahona
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Robert Anderson
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Hodges Davis
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Kevin J Wing
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Murray J Penner
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| |
Collapse
|
29
|
|
30
|
Savage-Elliott I, Wu VJ, Wu I, Heffernan JT, Rodriguez R. Comparison of Time and Cost Savings Using Different Cost Methodologies for Patient-Specific Instrumentation vs Standard Referencing in Total Ankle Arthroplasty. FOOT & ANKLE ORTHOPAEDICS 2019; 4:2473011419884278. [PMID: 35097347 PMCID: PMC8697097 DOI: 10.1177/2473011419884278] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Background: Patient-specific 3-D printing cutting blocks (PSI) have been used instead of traditional intramedullary cutting guides. We hypothesized that PSI would lead to significantly decreased operating room (OR) time and significant cost savings to our institution with noninferior radiographic outcomes and no difference in expected vs actual implant size when compared with standard referencing (SR). Methods: Patients who had undergone total ankle replacements at our institution from 2013 through 2016 were included in the study. Associations between demographic variables and postoperative alignment in the SR vs PSI group were calculated using the Wilcoxon rank-sum test and the intraclass correlation coefficient. The cost of the operation was calculated using both an institutionally based fixed cost of OR time and using Time Driven Activity Based Cost (TDABC) accounting. A total of 43 patients were included in the study, 13 in the SR group and 30 in the PSI group. Results: Operative time (168 vs 137 minutes) and tourniquet time (123 vs 113 minutes) were significantly lower in the PSI vs the SR group. PSI predictions were accurate 100% of the time for tibial components and 83% of the time for talar components. Average costs of TAA using PSI were significantly reduced by $7597.00 when using traditional OR accounting, whereas PSI was $836.00 more expensive on average using TDABC accounting. Conclusion: Further research is needed to determine the cost-effectiveness of PSI vs SR in TAA; however, it does appear to save time intraoperatively. The long-term effect on clinical outcomes requires further study. Level of Evidence: Level III, case-control study.
Collapse
Affiliation(s)
- Ian Savage-Elliott
- Department of Orthopedic Surgery, Tulane University, New Orleans, LA, USA
| | - Victor J Wu
- Department of Orthopedic Surgery, Tulane University, New Orleans, LA, USA
| | - Isabella Wu
- Department of Orthopedic Surgery, Tulane University, New Orleans, LA, USA
| | | | - Ramon Rodriguez
- Department of Orthopedic Surgery, Tulane University, New Orleans, LA, USA
| |
Collapse
|
31
|
Abstract
Total ankle arthroplasty has been in development for more than 40 years. Although early designs were experimental with high failure rates, current implants are significantly improved, showing promising functional results and clinical outcomes. Total ankle replacement designs are split into mobile-bearing and fixed-bearing designs. When deciding whether to perform ankle arthroplasty, many factors need to be considered to determine if the patient is suitable and which implant is the best fit for patient and surgeon. Many prostheses are available in the United States today and the purpose of this article is to outline options for foot and ankle surgeons.
Collapse
Affiliation(s)
- Amber Shane
- Department of Podiatric Surgery, Advent East Podiatric Surgical Residency, Advent Health System, Orlando Foot and Ankle Clinic, 250 North Alafaya Trail Suite 115, Orlando, FL 32828, USA.
| | - Hannah Sahli
- Department of Podiatric Surgery, Advent Health System, 250 North Alafaya Trail Suite 115, Orlando, FL 32828, USA
| |
Collapse
|
32
|
Saito GH, Sanders AE, O'Malley MJ, Deland JT, Ellis SJ, Demetracopoulos CA. Accuracy of patient-specific instrumentation in total ankle arthroplasty: A comparative study. Foot Ankle Surg 2019; 25:383-389. [PMID: 30321969 DOI: 10.1016/j.fas.2018.02.008] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 01/22/2018] [Accepted: 02/05/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Patient-specific instrumentation (PSI) for TAA is a novel technology with several potential benefits. The primary goal of this study was to compare the use of PSI with the standard referencing guide (SRG) in regards to accuracy of tibial implant positioning. Operative time, fluoroscopy time and accuracy of PSI preoperative reports were also evaluated. METHODS A retrospective analysis of 99 patients who underwent a primary TAA with the INFINITY prosthesis (Wright Medical, Memphis, TN) was performed. Patients were divided in two groups based on the type of instrumentation used during the TAA (75 in the PSI group vs 24 in the SRG group). There was no significant difference between groups in regards to age at the time of surgery (P=0.122), sex (P=0.138), number of concomitant procedures performed during surgery (P=0.567) and etiology (P=0.841). However, preoperative deformity was significantly smaller in the PSI group (P=0.002). RESULTS Tibial implant positioning was similar between groups. In the coronal plane, the absolute deviation of the tibial implant from the intended alignment was 1.7±1.4° for the SRG and 1.6±1.2° for PSI (P=0.710). In the sagittal plane, the absolute alignment deviation of the tibial implant was 1.8±1.4° for the SRG and 1.9±1.5° for PSI (P=0.675). Operative time (167 vs 190min, P=0.040) and fluoroscopy time (85 vs 158s, P<0.001) were significantly decreased in the PSI group. The PSI preoperative plan report correctly predicted the implant size in 73% of cases for the tibial component and in 51% of cases for the talar component. CONCLUSIONS PSI provided similar tibial component alignment as standard instrumentation. Additionally, PSI preoperative plan reports were poor predictors of implant sizing. Therefore, the final decision should always be based on surgeon's experience in order to prevent errors in implant sizing and positioning. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
Affiliation(s)
- Guilherme H Saito
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021, United States.
| | - Austin E Sanders
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| | - Martin J O'Malley
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| | - Jonathan T Deland
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| | - Scott J Ellis
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| | - Constantine A Demetracopoulos
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| |
Collapse
|
33
|
Jordan Y, Buchowski JM, Mokkarala M, Peters C, Bumpass DB. Outcomes and cost-minimization analysis of cement spacers versus expandable cages for posterior-only reconstruction of metastatic spine corpectomies. ANNALS OF TRANSLATIONAL MEDICINE 2019; 7:212. [PMID: 31297377 DOI: 10.21037/atm.2019.05.07] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Background Reconstruction of the thoracolumbar spine after tumor corpectomy can be accomplished using either an expandable metallic cage (EC) or a polymethylmethacrylate (PMMA) cement spacer. Few studies have compared the relative successes between these two forms of reconstructions in the management of metastatic spine disease (MSD). The purpose of this study was to compare both the outcomes and costs of EC and PMMA spacers in the treatment of MSD. We hypothesized that the rate of complications and revision surgery when using PMMA spacers to reconstruct the spine after corpectomy for MSD would be equivalent to use of an EC, with lower implant and operating room (OR) costs. Methods A single surgeon performed 65 vertebral corpectomies for MSD requiring anterior column reconstruction from 2007-2014. Charts were retrospectively reviewed and no patients were excluded. All resections were single-stage resections/reconstructions of the vertebral body through a posterior-only approach. Outcomes evaluated included perioperative complications, intraoperative time, postoperative survival, subsequent reoperations, and changes in radiographic spinal alignment. Results Thirty-six patients were treated with PMMA spacers; 29 were treated with EC. Baseline age, BMI, comorbidities, and disease severity as measured by Tokuhashi scores were equivalent between treatment groups. The cohorts had no significant differences in operative complications, blood loss, postoperative survival, number of subsequent reoperations, or changes in radiographic alignment. PMMA patients had a significantly shorter mean operative duration (328.6 vs. 241.1 min, P<0.001). Institutional implant cost savings were $4,355 favoring the PMMA cohort ($75 for cement vs. $5,000 for cage). Mean OR time savings were calculated to be $2,001 less for the PMMA cohort. Total cost minimization per PMMA case was thus $6,356, which was robust in 2-way sensitivity analyses varying both implant costs and time costs by 30%. Conclusions In the largest series of posterior-only corpectomies for MSD reconstructed with PMMA, PMMA intervertebral spacers provided equivalent stability and longevity to EC, at a fraction of the cost. PMMA showed excellent durability while minimizing costs by $6,356 per case, an important consideration as reimbursement pressures increasingly influence surgical decision making.
Collapse
Affiliation(s)
- Yusef Jordan
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Jacob M Buchowski
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Mahati Mokkarala
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Colleen Peters
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - David B Bumpass
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| |
Collapse
|
34
|
Penner M, Davis WH, Wing K, Bemenderfer T, Waly F, Anderson RB. The Infinity Total Ankle System: Early Clinical Results With 2- to 4-Year Follow-up. Foot Ankle Spec 2019; 12:159-166. [PMID: 29865886 PMCID: PMC6507063 DOI: 10.1177/1938640018777601] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
AIMS This study presents the first report of clinical and radiographic outcomes of the Infinity Total Ankle System (Wright Medical, Memphis, TN) with minimum 2-year follow-up. PATIENTS AND METHODS The first 67 consecutive patients who underwent primary total ankle arthroplasty (TAA) with the Infinity system at 2 North American sites between August 2013 and May 2015 were reviewed in a prospective, observational study. Demographic, radiographic, and functional outcome data were collected preoperatively, at 6 to 12 months postoperatively, and annually thereafter. RESULTS The overall implant survival rate was 97% (65 of 67 implants) at a mean follow-up of 35.4 months (27 to 47 months). Two cases underwent talar component revision for aseptic loosening. Six of the 67 cases (9%) required a nonrevision reoperation. Mean Foot Function Index and Ankle Osteoarthritis Scale scores at latest follow-up improved from preoperative by 21.6 ( P < .0001) and 34.0 ( P < .0001), respectively. No radiographic loosening of any talar or tibial components was identified in the 65 nonrevised cases. CONCLUSION Early clinical and radiographic outcomes with the Infinity TAA are promising and compare favorably to those reported for both fixed- and mobile-bearing third-generation TAA designs, even when used in cases with deformity and increased case complexity. LEVELS OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Murray Penner
- Murray Penner, MD, FRCSC, Department of
Orthopaedics, University of British Columbia, 560-1144 Burrard Street,
Vancouver, British Columbia V6Z 2A5, Canada; e-mail:
| | | | | | | | | | | |
Collapse
|
35
|
Cody EA, Taylor MA, Nunley JA, Parekh SG, DeOrio JK. Increased Early Revision Rate With the INFINITY Total Ankle Prosthesis. Foot Ankle Int 2019; 40:9-17. [PMID: 30175612 DOI: 10.1177/1071100718794933] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND: A number of new 2-component total ankle arthroplasty systems that emphasize minimal bone resection have been introduced for which few clinical outcomes reports are available. Our aim was to identify the rate of early revision among patients receiving the 2-component INFINITY prosthesis. METHODS: Patients from 2 prospectively collected databases at the authors' institution were screened for inclusion in the present study. All patients who underwent a primary total ankle arthroplasty (TAA) with the INFINITY prosthesis and who were at least 1 year postoperative were included. A total of 159 ankles with a mean 20 months of follow up (range, 12-37) met these criteria. All surgeries were performed by 1 of 2 orthopedic foot and ankle surgeons with extensive experience in TAA. The primary outcome was the need for revision surgery, defined as removal of 1 or both metal components. Peri-implant lucency at most recent follow-up was a secondary outcome. Weightbearing radiographs at most recent follow-up were graded for lucency independently by 2 reviewers. RESULTS: Sixteen ankles (10%) underwent revision at a mean 13 months postoperatively. The most common reasons for revision were symptomatic tibial component loosening and deep infection (6 patients each, 3.8%). Of the 108 ankles with retained components and at least 1 year of radiographic follow-up, 8 (7.4%) had global lucency around the tibial component suggestive of loosening at most recent follow-up. CONCLUSIONS: Our initial review of patients undergoing TAA with this new 2-component prosthesis demonstrates an elevated early revision rate due to tibial component loosening compared to other implant systems. LEVEL OF EVIDENCE: Level IV, case series.
Collapse
|
36
|
Sun Z, Li N, Zhang T, Xin J, Ma X. [Progress of total ankle arthroplasty for end-stage ankle osteoarthritis]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2018; 32:1313-1316. [PMID: 30215493 DOI: 10.7507/1002-1892.201803028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To review the progress of total ankle arthroplasty (TAA) in treatment of end-stage ankle osteoarthritis (AOA). Methods The domestic and foreign literatures about TAA in recent years were reviewed. The current status and progress of TAA were summarized from the results of traditional and computer-assisted TAA clinical outcomes. Results End-stage AOA often leads to severe pain and dysfunction, and arthrodesis is still the main selective treatment option. In recent years, with the advancement of surgical techniques and prosthesis design, TAA which can remain joint mobility has increased gradually, and the surgical results also have significant progress. Accurate prosthesis implant and mechanical alignment restoration are critical factors for TAA, and surgery-related malalignment is correlative to the prosthesis failure. Computer assisted patient-specific guide can simplify the TAA procedures and obtain the accuracy of tibia and talus osteotomy. Conclusion The clinical efficiency of preoperative CT based patient-specific guide technology for TAA needs further clinical follow-up. Meanwhile, it is necessary to further develop intraoperative navigation and robotic surgery system suitable for TAA.
Collapse
Affiliation(s)
- Zhenhui Sun
- Department of Foot and Ankle Surgery, Tianjin Hospital, Tianjin, 300211, P.R.China[]
| | - Nan Li
- Department of Foot and Ankle Surgery, Tianjin Hospital, Tianjin, 300211, P.R.China[]
| | - Tao Zhang
- Department of Foot and Ankle Surgery, Tianjin Hospital, Tianjin, 300211, P.R.China[]
| | - Jingyi Xin
- Department of Foot and Ankle Surgery, Tianjin Hospital, Tianjin, 300211, P.R.China[]
| | - Xinlong Ma
- Department of Foot and Ankle Surgery, Tianjin Hospital, Tianjin, 300211, P.R.China[]
| |
Collapse
|
37
|
Use of CT Scan-derived Patient-specific Instrumentation in Total Ankle Arthroplasty. TECHNIQUES IN FOOT & ANKLE SURGERY 2017. [DOI: 10.1097/btf.0000000000000175] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|