1
|
Lewis TL, Trowbridge S, Franklin S, Lau B, Shehata R, Lyle S, Ray R. Cartiva interpositional arthroplasty versus arthrodesis in the treatment of Hallux rigidus: A retrospective comparative study with mean 2 year follow up. Foot Ankle Surg 2024; 30:587-593. [PMID: 38744636 DOI: 10.1016/j.fas.2024.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 05/06/2024] [Indexed: 05/16/2024]
Abstract
BACKGROUND Hallux rigidus is a common condition characterised by first metatarsophalangeal joint (MTPJ) degeneration, pain and limited range of motion (ROM). The gold standard surgical treatment is arthrodesis, providing good pain relief, but sacrifices ROM. The Cartiva synthetic cartilage implant (SCI) has been utilised as an interpositional arthroplasty, aiming to reduce pain whilst preserving range of motion. Current evidence for Cartiva SCI is limited. The aim was to evaluate the clinical outcomes of Cartiva SCI compared to arthrodesis undertaken in our centre. METHODS A retrospective cohort study was conducted, enrolling all adult patients who underwent primary first MTPJ SCI arthroplasty or arthrodesis for the treatment hallux rigidus. The primary outcome was a validated patient-reported outcome measure (PROM), the Manchester-Oxford Foot Questionnaire (MOXFQ). Secondary outcomes included EQ-5D, complication rates, VAS Pain and FAAM (ADL). RESULTS Between 2017 and 2020 there were 33 cases divided into two groups (17 Cartiva SCI, 16 arthrodesis, mean age 59.0 ± 9.9 years) with a mean follow up of 2.3 years. There was no statistically significant difference in any of the MOXFQ, EQ-5D, VAS Pain or FAAM (ADL) outcome scores between the Arthrodesis and SCI groups (p > 0.05). The mean MOXFQ Index score was 7.2 ± 6.4 for the SCI group and 3.9 ± 5.8 for the Arthrodesis group at final follow up (p = 0.15). Although complications were high in both groups, the overall hallux reoperation rate was 29.4 % in the SCI cohort and 0.0 % for arthrodesis. CONCLUSION This retrospective comparative study found no significant superiority of Cartiva SCI over arthrodesis in terms of PROMs. Due to the higher rate of further surgical intervention in the SCI cohort, we recommend arthrodesis as the preferred surgical option for hallux rigidus. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- T L Lewis
- King's Foot and Ankle Unit, King's College NHS Foundation Trust, United Kingdom.
| | - S Trowbridge
- King's Foot and Ankle Unit, King's College NHS Foundation Trust, United Kingdom
| | - S Franklin
- King's Foot and Ankle Unit, King's College NHS Foundation Trust, United Kingdom
| | - B Lau
- King's Foot and Ankle Unit, King's College NHS Foundation Trust, United Kingdom
| | - R Shehata
- King's Foot and Ankle Unit, King's College NHS Foundation Trust, United Kingdom
| | - S Lyle
- King's Foot and Ankle Unit, King's College NHS Foundation Trust, United Kingdom
| | - R Ray
- King's Foot and Ankle Unit, King's College NHS Foundation Trust, United Kingdom
| |
Collapse
|
2
|
Fletcher WR, Collins T, Fox A, Pillai A. Mid-term efficacy of the Cartiva synthetic cartilage implant in symptomatic hallux rigidus. Bone Jt Open 2024; 5:799-805. [PMID: 39314066 PMCID: PMC11420640 DOI: 10.1302/2633-1462.59.bjo-2024-0031.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/25/2024] Open
Abstract
Aims The Cartiva synthetic cartilage implant (SCI) entered mainstream use in the management of first metatarsophalangeal joint (MTPJ) arthritis following the positive results of large trials in 2016. Limited information is available on the longer-term outcomes of this implant within the literature, particularly when independent from the originator. This single-centre cohort study investigates the efficacy of the Cartiva SCI at up to five years. Methods First MTPJ arthritis was radiologically graded according to the Hattrup and Johnson (HJ) classification. Preoperative and sequential postoperative patient-reported outcome measures (PROMs) were evaluated using the Manchester-Oxford Foot Questionnaire (MOXFQ), and the activities of daily living (ADL) sub-section of the Foot and Ankle Ability Measure (FAAM). Results Patients were followed up for a mean of 66 months (SD 7.1). Of an initial 66 cases, 16 did not return PROM questionnaires. A total of six failures were noted, with survival of 82%. Overall, significant improvement in both objective scores (MOXFQ and FAAM ADL) was maintained versus preoperatively: 18.2 versus 58.0 (p > 0.001) and 86.2 versus 41.1 (p > 0.001), respectively. The improvement was noted to be less pronounced in males. Subjective scores had deteriorated since early follow-up, with an interval decrease in patient satisfaction from 89% to 68%. Furthermore, a subset of cases demonstrated clinically important interval deterioration in objective scores. However, no specific patient factors were found to be associated with outcomes following analysis. Conclusion This study represents the longest-term independent follow-up in the literature. It shows reassuring mid-term efficacy of the Cartiva SCI with better-than-expected survival. However, deterioration in scores for a subset of patients and lower satisfaction may predict ongoing failure in this group of patients. Additionally, males were noted to have a lower degree of improvement in scores than females. As such, ongoing observation of the SCI to assess durability and survivability, and identify predictive factors, is key to improving patient selection.
Collapse
Affiliation(s)
| | | | - Anna Fox
- Orthopaedics, Wythenshawe Hospital, Manchester, UK
| | - Anand Pillai
- Orthopaedics, Wythenshawe Hospital, Manchester, UK
| |
Collapse
|
3
|
Budde K, Claassen L, Plaass C, Stukenborg-Colsman C, Daniilidis K, Yao D. Synthetic cartilage implant vs. first metatarsophalangeal arthrodesis for the treatment of hallux rigidus. Arch Orthop Trauma Surg 2024:10.1007/s00402-024-05534-9. [PMID: 39287788 DOI: 10.1007/s00402-024-05534-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Accepted: 09/01/2024] [Indexed: 09/19/2024]
Abstract
BACKGROUND This study evaluated the outcome of the Cartiva synthetic cartilage implant (SCI) in the treatment of hallux rigidus. METHODS In the present retrospective matched case-control study, we compared 18 patients with Cartiva SCI (mean follow-up: 17.7 months) to 18 patients with metatarsophalangeal joint arthrodesis (mean follow-up: 20 months) using multiple function measures, along with four specified visual analog subscales for pain. Pre- and postoperative radiographs were compared, and radiographic abnormalities were documented. RESULTS We observed no significant differences in function measures between groups. While both groups experienced significant pain reduction, the arthrodesis group reported significantly lower exertion pain than the Cartiva SCI group (p = 0.004). Radiographic abnormalities, including implant site enlargement (6/18, 33.3%), erosive changes of the metatarsal bone (11/18, 61.1%) or articular surfaces (10/18, 55.6%), and bright sclerotic margins (12/18, 66.7%), occurred in the Cartiva SCI group. CONCLUSION The present study showed good functional results and a high satisfaction rate after MTP joint arthrodesis, which is considered the gold standard surgical treatment for higher grade hallux rigidus. While the Cartiva SCI group did not show significant differences from the arthrodesis in most aspects of function and clinical scores, the arthrodesis group tended to have better results in terms of satisfaction, residual pain, and revision rate. Even after the short follow-up period, there were some remarkable radiographic findings in the Cartiva SCI group, the long-term effects of which are not yet evident, but which may lead to implant loss. Cartiva SCI has advantages for patients who prioritize postoperative mobility, but the potential risks should be considered in the patient's informed consent. Therefore, the present study highlights the importance of MTP joint arthrodesis for the treatment of hallux rigidus. LEVEL OF EVIDENCE Level IV - Retrospective matched case-control study.
Collapse
Affiliation(s)
- Konrad Budde
- Orthopedic Department, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
| | - Leif Claassen
- Orthopedic Department, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany
- Rueckenprofis Hannover, Luisenstraße 10-11, 30159, Hannover, Germany
| | - Christian Plaass
- Orthopedic Department, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany
| | | | | | - Daiwei Yao
- Orthopedic Department, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany
- Emma Klinik, Klinik für operative Medizin GmbH & Co. KG, Frankfurter Straße 51, 63500, Seligenstadt, Germany
| |
Collapse
|
4
|
Daniels T, Cristofaro C, Halai M. Cartiva: A Review of the Best Evidence. Foot Ankle Clin 2024; 29:485-493. [PMID: 39068023 DOI: 10.1016/j.fcl.2023.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/30/2024]
Abstract
The Cartiva implant is a synthetic polyvinyl alcohol hydrogel cartilage substitute that is used as a treatment of first metatarsophalangeal joint arthritis. The implant was designed to relieve the pain associated with hallux rigidus while preserving or restoring range of motion. A summary of outcomes, reasons for these outcomes, and technique pearls will be reviewed here. Seminal articles and current evidence are all included in this article. The aim is for the surgeon to understand all the literature, allowing the surgeon to counsel their patients appropriately, optimize patient selection and to deal with complications.
Collapse
Affiliation(s)
- Timothy Daniels
- Department of Orthopaedics, University of Toronto, Canada; Department of Orthopaedics, St Michael's Hospital, Toronto, Canada
| | - Caroline Cristofaro
- Department of Orthopaedics, University of Toronto, Canada; Department of Orthopaedics, St Michael's Hospital, Toronto, Canada
| | - Mansur Halai
- Department of Orthopaedics, University of Toronto, Canada; Department of Orthopaedics, St Michael's Hospital, Toronto, Canada.
| |
Collapse
|
5
|
Chopra A, Fletcher AN, Madi NS, Parekh SG. Revision Surgery After Failed Index Synthetic Cartilage Implant Resurfacing for Hallux Rigidus: Single-Surgeon 5-Year Experience. Foot Ankle Spec 2024; 17:365-374. [PMID: 36727310 DOI: 10.1177/19386400221147773] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND While metatarsophalangeal joint (MTPJ) arthrodesis is regarded as the gold standard treatment option for end-stage hallux rigidus (HR), synthetic cartilage implant (SCI) resurfacing has gained popularity. This study aimed to identify the SCI resurfacing failure rate for a single surgeon, while also comparing clinical outcomes of patients who underwent SCI replacement or MTPJ arthrodesis after failed index SCI resurfacing. METHODS Health records were queried from 2016 to 2021 for patients with HR who were treated with SCI resurfacing by a single surgeon. Preoperative and postoperative range of motion, visual analog scale (VAS) pain scores, and hallux valgus angles were compared. A subgroup analysis was performed on patients who underwent revision with SCI replacement or MTPJ arthrodesis. SCI replacement included the use of bone graft, bone putty, or a custom 3D printed baseplate to prevent implant subsidence. RESULTS A total of 219 SCI resurfacing procedures were performed by a single surgeon, including 23 revisions. When analyzing index procedures, an 8.2% revision rate was determined. The revision cohort (n = 23) consisted of 19 female patients and presented with a mean body mass index of 29.5 ± 5 kg/m2, mean age of 52.8 ± 11 years, mean follow-up duration of 22.3 (range, 3-54) months, and mean time to a revision surgery of 12.1 ± 12 (range, 1-50) months. Specifically, 12 procedures resulted in an SCI replacement, while 11 procedures resulted in arthrodesis. While all patients experienced significant improvement in their VAS pain scores (P < .001), the arthrodesis cohort experienced a greater improvement than the SCI revision cohort (P = .04). CONCLUSION When analyzing SCI revision procedures, MTPJ arthrodesis reduced pain more significantly than SCI replacement. LEVELS OF EVIDENCE Level IV: Retrospective case series.
Collapse
Affiliation(s)
- Aman Chopra
- Georgetown University School of Medicine, Washington, District of Columbia
| | - Amanda N Fletcher
- Department of Orthopaedic Surgery, Duke University, Durham, North Carolina
| | - Naji S Madi
- Department of Orthopaedic Surgery, Duke University, Durham, North Carolina
| | | |
Collapse
|
6
|
Butler JJ, Dhillon R, Wingo T, Lin CC, Samsonov AP, Azam MT, Kennedy JG. Polyvinyl alcohol hydrogel implant for the treatment of hallux rigidus is associated with a high complication rate and moderate failure rate at short-term follow-up: a systematic review. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:1765-1778. [PMID: 38554163 DOI: 10.1007/s00590-024-03895-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Accepted: 02/28/2024] [Indexed: 04/01/2024]
Abstract
PURPOSE Moderate-to-severe hallux rigidus is a debilitating pathology that is optimally treated with surgical intervention. Arthrodesis produces reliable clinical outcomes but is limited by restriction in 1st metatarsophalangeal joint range of motion. The advent of polyvinyl alcohol hydrogel (PVA) implants have produced early promise based on initial trials, but more recent studies have called into question the efficacy of this procedure. The purpose of this systematic review was to evaluate the clinical and radiological outcomes following the use of PVA for hallux rigidus. METHODS The MEDLINE, EMBASE and Cochrane library databases were systematically reviewed using the preferred reporting items for systematic reviews and meta-analyses guidelines. 18 studies were included. RESULTS In total, 1349 patients (1367 feet) underwent PVA at a weighted mean follow-up of 24.1 ± 11.1 months. There were 168 patients (169 feet) included in the cheilectomy cohort and 322 patients (322 feet) included in the arthrodesis cohort. All 3 cohorts produced comparable improvements in subjective clinical outcomes. Postoperative imaging findings in the PVA cohort included joint space narrowing, peri-implant fluid, peri-implant edema and erosion of the proximal phalanx. The complication rate in the PVA cohort, cheilectomy cohort and arthrodesis cohort was 27.9%, 11.8% and 24.1%, respectively. The failure rates in the PVA cohort, cheilectomy cohort and arthrodesis cohort was 14.8%, 0.3% and 9.0%, respectively. CONCLUSION This systematic review demonstrated that PVA produced a high complication rate (27.9%) together with concerning postoperative imaging findings at short-term follow-up. In addition, a moderate failure rate (14.8%) and secondary surgical procedure rate (9.5%) was noted for the PVA cohort. The findings of this review calls into question the efficacy and safety of PVA for the treatment of hallux rigidus. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- James J Butler
- Foot and Ankle Division, Department of Orthopaedic Surgery, NYU Langone Health, 171 Delancey Street, 2nd Floor, New York, NY, 10002, USA.
| | | | - Taylor Wingo
- Foot and Ankle Division, Department of Orthopaedic Surgery, NYU Langone Health, 171 Delancey Street, 2nd Floor, New York, NY, 10002, USA
| | - Charles C Lin
- Foot and Ankle Division, Department of Orthopaedic Surgery, NYU Langone Health, 171 Delancey Street, 2nd Floor, New York, NY, 10002, USA
| | - Alan P Samsonov
- Foot and Ankle Division, Department of Orthopaedic Surgery, NYU Langone Health, 171 Delancey Street, 2nd Floor, New York, NY, 10002, USA
| | - Mohammad T Azam
- Foot and Ankle Division, Department of Orthopaedic Surgery, NYU Langone Health, 171 Delancey Street, 2nd Floor, New York, NY, 10002, USA
| | - John G Kennedy
- Foot and Ankle Division, Department of Orthopaedic Surgery, NYU Langone Health, 171 Delancey Street, 2nd Floor, New York, NY, 10002, USA.
| |
Collapse
|
7
|
Lee W, Wang C, Prat D, Wapner KL, Chao W, Farber DC. Patient Satisfaction Following Hallux Rigidus Treatment With a Synthetic Cartilage Implant. Foot Ankle Spec 2023; 16:527-536. [PMID: 33769110 DOI: 10.1177/19386400211001993] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND There remains no clear consensus on patient satisfaction and functional outcomes following synthetic cartilage implant (SCI) implantation for hallux rigidus. The purpose of this study was to review our experience at a single academic institution using an SCI for treatment of hallux rigidus. METHODS A retrospective review was performed of patients who underwent the SCI procedure for treatment of hallux rigidus between January 2017 and May 2019. Functional outcomes were evaluated using Patient-Reported Outcome Measures Informational System (PROMIS)-10 scores as well as a survey investigating patient satisfaction, self-reported clinical improvement, and changes in sporting ability. Patients were divided into satisfied versus unsatisfied subgroups, and between-group differences in preoperative variables and complications were reviewed. A total of 90 patients (96 implants) were included in this study. The mean follow-up time was 26.4 months. RESULTS In all, 81.2% of patients reported that their foot was "much improved" (55.2%) or "improved" (26.0%) since undergoing the SCI procedure, whereas a slightly lower percentage, 74.0%, stated that they were "extremely satisfied" (41.7%) or "satisfied" (32.3%) at final follow-up. Patients were able to tolerate higher impact sporting activities after the procedure, and 75.0% of patients stated they would have the same surgery again. PROMIS-10 T-scores averaged 54.2 points for physical health and 57.4 points for mental health. Only 2.1% of patients required conversion to arthrodesis. Significant differences between the satisfied versus unsatisfied subgroups were found in preoperative corticosteroid injection use (21.1% vs 41.1%, respectively; P = .029) and preoperative VAS pain score (8.2 vs 7.1, respectively; P = .036). CONCLUSION The SCI procedure can be a viable option for treating hallux rigidus with high satisfaction overall, increased sport activity levels, and a very low revision rate. However, maximizing patient satisfaction may require more careful consideration of preoperative prognosticators and extensive patient counseling to ensure realistic expectations for recovery time and individual outcome. LEVEL OF EVIDENCE Level IV: Retrospective case series.
Collapse
Affiliation(s)
- Wonyong Lee
- Division of Foot and Ankle Surgery, Department of Orthopaedic Surgery, University of Pennsylvania Health System, Philadelphia, Pennsylvania
| | - Carol Wang
- Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Dan Prat
- Division of Foot and Ankle Surgery, Department of Orthopaedic Surgery, University of Pennsylvania Health System, Philadelphia, Pennsylvania
| | - Keith L Wapner
- Division of Foot and Ankle Surgery, Department of Orthopaedic Surgery, University of Pennsylvania Health System, Philadelphia, Pennsylvania
| | - Wen Chao
- Division of Foot and Ankle Surgery, Department of Orthopaedic Surgery, University of Pennsylvania Health System, Philadelphia, Pennsylvania
| | - Daniel C Farber
- Division of Foot and Ankle Surgery, Department of Orthopaedic Surgery, University of Pennsylvania Health System, Philadelphia, Pennsylvania
| |
Collapse
|
8
|
Schapira B, Johnson O, Faroug R. Surgical Outcomes of Synthetic Cartilage Implant Hemiarthroplasty for Metatarsophalangeal Arthropathy. Cureus 2023; 15:e49036. [PMID: 38116339 PMCID: PMC10728759 DOI: 10.7759/cureus.49036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/18/2023] [Indexed: 12/21/2023] Open
Abstract
Introduction Metatarsophalangeal joint (MTPJ) arthropathy in the great toe causes considerable pain and debilitation, severely impacting quality of life. Traditional management options included conservative measures, steroid injections, and arthrodesis. New options include Cartiva, a synthetic cartilage hemiarthroplasty for the MTPJ. This prosthesis has evidence of improved pain and function without the sacrifice of joint movement seen with arthrodesis. However, the implant itself has mixed reviews. This study aims to identify the pre-, peri, and short-term post-surgical outcomes of Cartiva surgery and review the literature for existing reported outcomes. Methods We retrospectively reviewed a cohort of 22 consecutive Cartiva procedures between 2016 and 2022 in a single UK institution. Hospital records were analyzed for peri-operative complications, implant survival, additional operative interventions, patient-reported outcomes, and functional improvement. Results Twenty-one patients underwent Cartiva for the first MTPJ pathology and one for the third MTPJ pathology. Prior to surgery, 40.9% of patients had undergone alternative therapies, including MTPJ steroid injections (seven patients), cheilectomy (four patients), and bunionectomy (one patient). Total complication rates, inclusive of medical, surgical, and implant complications were 45.5% (10/22). Total reoperation rates were 18.2% (4/22) including two revisions to arthrodesis and two manipulations under anesthesia (MUA) with local anesthetic injection. At the final follow-up, 55% were still experiencing pain, 15% neurovascular symptoms, 10% swelling, and 50% stiffness or reduced range of movement. However, 85% of patients returned to usual activities of daily living within two years. Conclusion Cartiva surgery for metatarsophalangeal arthropathy has demonstrated outcomes of persistent pain, limited range of movement, and restricted function at short-term follow-up. Rates of reoperation and revision to arthrodesis were comparable with similar studies.
Collapse
Affiliation(s)
| | - Oscar Johnson
- Trauma and Orthopedics, Lister Hospital, Stevenage, GBR
| | | |
Collapse
|
9
|
Guyton GP. Philosophies of Surgical Care Are Embedded in Outcome Studies: An Illustrative Reanalysis of the Cartiva MOTION Trial. Foot Ankle Int 2022; 43:1364-1369. [PMID: 35979930 DOI: 10.1177/10711007221112928] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Subjective assumptions on the definition of surgical success are inherent to the design of clinical trials with a categorial outcome. The current study used reasonable alternative assumptions about surgical care to reassess data for the randomized controlled Cartiva trial (MOTION). METHODS Data from the published study were augmented by publicly accessible internal US Food and Drug Administration documents. As in the published report, 1-sided lower bound 95% CIs (LBCI95) for the difference of proportions were calculated for a series of alternative scenarios in which the assumptions underlying what constitutes surgical success were altered. RESULTS Using a noninferiority margin of -15%, the MOTION trial reported success based on a 1-sided LBCI95 of -10.9%. Each of the 3 independent alternative scenarios analyzed yielded results that altered the primary outcome of the trial: (1) eliminating failures based solely upon radiographs findings, thereby considering a painless pseudarthrosis as a success (1-sided LBCI95 of -15.9%), (2) considering only major surgical revision as a failure and discounting isolated hardware removal (1-sided LBCI95 of -15.1%), and (3) using a visual analog scale (VAS) pain threshold of <30 as the success criterion rather than a 30% reduction in VAS pain score (1-sided LBCI95 of -15.8%). CONCLUSION In this reanalysis, applying any of 3 reasonable alternative assumptions about the definition of surgical success to the data resulted in failure to prove noninferiority of Cartiva over arthrodesis, a reversal of the reported trial result. These results highlight the effect of subjective assumptions in the design of clinical trials with a categorical outcome and illustrate how differing philosophies about what constitutes surgical success can be pivotal in determining the final result. LEVEL OF EVIDENCE Level II, prospective comparative study.
Collapse
Affiliation(s)
- Gregory P Guyton
- Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD, USA
| |
Collapse
|
10
|
Zanzinger C, Harrasser N, Gottschalk O, Dolp P, Hinterwimmer F, Hoerterer H, Walther M. One-year Follow-Up Results with Hydrogel Implant in Therapy of Hallux Rigidus: Case Series with 44 Patients. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2022; 160:414-421. [PMID: 33647994 DOI: 10.1055/a-1365-9655] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
BACKGROUND The Cartiva implant (CI) is being increasingly used in the surgical therapy of hallux rigidus. Despite a growing number of studies, numerous questions regarding patient selection remain unanswered. PATIENTS AND METHODS As part of a retrospective case series with prospective follow-up (average follow-up period: 12 months), a total of 44 patients (male/female = 16/28; mean age at the time of surgery: 55.4 years) with 44 CI were analysed (VAS, EFAS-, AOFAS-score). Using a correlation analysis and a machine learning algorithm, risk factors for therapy failure were investigated. RESULTS The overall survival rate of the CI was 93% at 12 months. The VAS, EFAS and AOFAS scores showed a significant improvement in comparison to the preoperative condition. The mobility of the metatarsophalangeal joint showed no increase. Patients with a medium osteoarthritis grade and a medium level of clinical restraint showed the greatest improvement in relation to their preoperative condition. CONCLUSION The CI can be seen as an effective therapy for hallux rigidus. Nonetheless, realistic patient expectations must be communicated.
Collapse
Affiliation(s)
- Christoph Zanzinger
- Specialist Centre for Foot and Ankle Joint Surgery, Schön Clinic Munich-Harlaching, Munich, Germany
| | - Norbert Harrasser
- Orthopaedics, Clinics Rechts der Isar of the Technical University of Munich, Germany
| | - Oliver Gottschalk
- Specialist Centre for Foot and Ankle Joint Surgery, Schön Clinic Munich-Harlaching, Munich, Germany.,Department of Gerneral, Trauma and Reconstructive Surgery, LMU Munich, Germany
| | - Patrick Dolp
- Specialist Centre for Foot and Ankle Joint Surgery, Schön Clinic Munich-Harlaching, Munich, Germany
| | - Florian Hinterwimmer
- Orthopaedics, Clinics Rechts der Isar of the Technical University of Munich, Germany
| | - Hubert Hoerterer
- Specialist Centre for Foot and Ankle Joint Surgery, Schön Clinic Munich-Harlaching, Munich, Germany.,Department of Gerneral, Trauma and Reconstructive Surgery, LMU Munich, Germany
| | - Markus Walther
- Specialist Centre for Foot and Ankle Joint Surgery, Schön Clinic Munich-Harlaching, Munich, Germany
| |
Collapse
|
11
|
Metikala S, Mahmoud K, O'Connor KM, Chao W, Wapner KL, Farber DC. Adverse Events Related to Cartiva Hemiarthroplasty of First Metatarsal: An Analysis of Reports to the United States Food and Drug Administration. Foot Ankle Spec 2022; 15:113-118. [PMID: 32723089 DOI: 10.1177/1938640020943715] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background: The results supporting Cartiva, a synthetic cartilage implant (Wright Medical) in hallux rigidus have come from limited institutions creating observational bias. Complications experienced in community centers are not routinely included in the published literature. To look at a broader range of potential complications, we reviewed the United States Food and Drug Administration's (FDA) voluntary device database and compared that data with published literature. Methods: The Manufacturer and User Facility Device Experience (MAUDE) database of the FDA was retrospectively reviewed between July 2016 and October 2019 using the product code: PNW, assigned for Cartiva. Results: A total of 49 events have been reported and implant subsidence was the most common with 16 reports. Others include fragmentation (9), infection (4), bone erosion (3), foreign body reaction (1) and unspecified (16). Thirty-five events mentioned further surgeries at a mean interval of 4.75 months. Conclusions: The analysis of the MAUDE database disclosed certain device-related dysfunctions that have been underreported in the published literature. Because of the voluntary nature of reporting, the true incidence of each complication is unknown with this data representing a baseline. The MAUDE database could be further strengthened by a more robust reporting mechanism or mandatory reporting of device-related complications.Levels of Evidence: Level IV: Case series from large database analysis.
Collapse
Affiliation(s)
- Sreenivasulu Metikala
- Department of Orthopaedic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania
| | - Karim Mahmoud
- Department of Orthopaedic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania
| | - Kathryn M O'Connor
- Department of Orthopaedic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania
| | - Wen Chao
- Department of Orthopaedic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania
| | - Keith L Wapner
- Department of Orthopaedic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania
| | - Daniel C Farber
- Department of Orthopaedic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania
| |
Collapse
|
12
|
Cercone M, Chevalier J, Kennedy JG, Miller AD, Fortier LA. Early Failure of a Polyvinyl Alcohol Hydrogel Implant With Osteolysis and Foreign Body Reactions in an Ovine Model of Cartilage Repair. Am J Sports Med 2021; 49:3395-3403. [PMID: 34424105 DOI: 10.1177/03635465211033601] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Hemiarthroplasty using a polyvinyl alcohol (PVA) hydrogel synthetic implant has been suggested as a good alternative to arthrodesis for the treatment of hallux rigidus. However, failure rates as high as 20% have been recorded. PURPOSE To characterize the pathological processes in bone, cartilage, and the synovial membrane after PVA hemiarthroplasty in an ovine model with 6 months of follow-up. STUDY DESIGN Controlled laboratory study. METHODS A unilateral osteochondral defect (8-mm diameter × 10-mm depth) was made in the medial femoral condyle in 6 sheep. Animals were randomized to receive a PVA implant (n = 4) or to have an empty defect (n = 2) and were monitored for 6 months. Patellofemoral radiographs were obtained at monthly intervals, and quantitative computed tomography was performed at the end of the study. After death, the joints were macroscopically evaluated and scored. Osteochondral and synovial membrane histological findings were assessed using modified Osteoarthritis Research Society International (OARSI) and aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) scoring systems. Immunohistochemistry using Iba1 was performed to evaluate activated macrophage infiltration. RESULTS Overall, 2 sheep with PVA implants were euthanized at 1 and 5 months because of uncontrollable pain and lameness (failed implants). Quantitative computed tomography showed that sheep with failed implants had 2.1-fold more osteolysis than those with successful implants. The sheep with failed implants had osteoarthritis with extensive glycosaminoglycan loss and cartilage fibrillation of the condyle and opposing tibial surface on histological examination. A foreign body reaction with severe chronic lymphoplasmacytic and granulomatous inflammation with giant cells was detected surrounding the implant. The synovial membrane ALVAL score was 9 of 19 and 14 of 19 in failed implants with synovial hyperplasia and lymphoplasmacytic and macrophage infiltration. In contrast, the synovial membrane in successful implants and empty defects was normal (ALVAL score = 0/19). Immunolabeling for Iba1 in failed implants confirmed extensive and dense macrophage infiltration within the condyle and synovial membrane, with the highest immunoreactive score (9/9). CONCLUSION PVA hydrogel implants had a 50% failure rate with uncontrollable pain, severe osteolysis, inflammation, and foreign body reactions. CLINICAL RELEVANCE The failure rate and pathological characteristics of the PVA implants suggest that their use should not be continued in human patients without further in vivo safety studies.
Collapse
Affiliation(s)
- Marta Cercone
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA
| | - Jacqueline Chevalier
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA
| | - John G Kennedy
- Department of Orthopedic Surgery, New York University Langone Health, New York, New York, USA
| | - Andrew D Miller
- Section of Anatomic Pathology, Department of Biomedical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA
| | - Lisa A Fortier
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA
| |
Collapse
|
13
|
Lunati M, Mahmoud K, Kadakia R, Coleman M, Bariteau J. Complications Associated with the Surgical Management of Hallux Rigidus. Orthop Clin North Am 2021; 52:291-296. [PMID: 34053574 DOI: 10.1016/j.ocl.2021.03.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Hallux rigidus is the most common arthritic pathology of the foot. This review article discusses the pathophysiology and common clinical presentation of hallux rigidus. Furthermore, we discuss multiple classification systems that categorize the arthritic process and guide management. Surgical interventions include cheilectomy, Moberg osteotomy, synthetic cartilage implants, interpositional arthroplasty, and arthrodesis. The common complications are reviewed, and the rates of these complications highlighted. Surgical options for hallux rigidus globally have successful outcomes with low rates of complications when done on appropriate patients.
Collapse
Affiliation(s)
- Matthew Lunati
- Department of Orthopaedic Surgery, Emory University School of Medicine, 59 Executive Park South, Suite 2000, Atlanta, GA 30329, USA
| | - Karim Mahmoud
- Department of Orthopaedic Surgery, Emory University School of Medicine, 59 Executive Park South, Suite 2000, Atlanta, GA 30329, USA
| | - Rishin Kadakia
- Department of Orthopaedic Surgery, Emory University School of Medicine, 59 Executive Park South, Suite 2000, Atlanta, GA 30329, USA
| | - Michelle Coleman
- Department of Orthopaedic Surgery, Emory University School of Medicine, 59 Executive Park South, Suite 2000, Atlanta, GA 30329, USA
| | - Jason Bariteau
- Department of Orthopaedic Surgery, Emory University School of Medicine, 59 Executive Park South, Suite 2000, Atlanta, GA 30329, USA.
| |
Collapse
|
14
|
Akoh CC, Chen J, Kadakia R, Park YU, Kim H, Adams SB. Adverse events involving hallux metatarsophalangeal joint implants: Analysis of the United States Food and Drug Administration data from 2010 to 2018. Foot Ankle Surg 2021; 27:381-388. [PMID: 32505511 DOI: 10.1016/j.fas.2020.05.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/27/2020] [Accepted: 05/08/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND The prevalence of osteoarthritis of the hallux metatarsophalangeal joint (MTPJ) is 1 in 40 people over the age of 50. Surgical treatment options for MTPJ arthritis include joint preservation, joint resurfacing, and arthrodesis. Hallux MTPJ implants have evolved over the past several decades, but are associated with various complications. The aim of this study was to examine the MAUDE database to determine reported adverse events for hallux MTPJ implants. MATERIALS AND METHODS The US Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience (MAUDE) database was reviewed from 2010 to 2018 to review voluntary reported adverse event reports for approved implants within the United States. We recorded the type of adverse event and excluded duplicate reports and those extracted from already published literature. RESULTS Among 64 reported hallux MTPJ implant adverse events, the most common modes of adverse events were component loosening (34%), infection (14.1%), component fracture (9.4%), inflammation (9.4%), and allergic reaction (7.8%). Regarding implant type, Cartiva SCI had the highest percentage of adverse events (23.4%), followed by Arthrosurface ToeMotion (20.3%), Ascension MGT (12.5%), Arthrosurface HemiCAP® (10.9%), Futura primus (9.4%), and Osteomed Reflexion (6.3%). There was an increase in reported adverse events after 2016. The MAUDE database does not report the total incidence of implant insertion. CONCLUSION Our study of the MAUDE database demonstrated that component loosening and infection are the most common modes of adverse events for hallux MTPJ implants. Cartiva accounted for one-fourth of the implant-related adverse events during our study period, followed by ToeMotion, and Ascension MGT implants. Continued reporting of adverse events will improve our understanding on short and long-term complications of various hallux MTPJ implants. LEVEL OF EVIDENCE Level IV; Case Series from Large Database Analysis; Treatment Study.
Collapse
Affiliation(s)
- Craig C Akoh
- Duke University Medical Center, Box 2887, Durham, NC 27710, United States.
| | - Jie Chen
- Duke University Medical Center, Box 2887, Durham, NC 27710, United States
| | - Rishin Kadakia
- Duke University Medical Center, Box 2887, Durham, NC 27710, United States
| | - Young Uk Park
- Department of Orthopedic Surgery, Ajou University Hospital, Ajou University School of Medicine, Suwon, Gyeonggido, Republic of Korea
| | - Hyongnyun Kim
- Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Republic of Korea
| | - Samuel B Adams
- Duke University Medical Center, Box 2887, Durham, NC 27710, United States
| |
Collapse
|
15
|
Shimozono Y, Hurley ET, Kennedy JG. Early Failures of Polyvinyl Alcohol Hydrogel Implant for the Treatment of Hallux Rigidus. Foot Ankle Int 2021; 42:340-346. [PMID: 33040611 DOI: 10.1177/1071100720962482] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this study was to evaluate the clinical and radiological outcomes following a polyvinyl alcohol hydrogel implant in the treatment of hallux rigidus. METHODS A retrospective cohort study investigating patients treated with a polyvinyl alcohol hydrogel implant for hallux rigidus was performed. Clinical outcomes were evaluated with the Foot and Ankle Outcomes Score (FAOS) and visual analog scale (VAS) score at the final follow-up. Plain radiographs were assessed postoperatively. Eleven patients (11 feet) with a mean follow-up of 20.9 months (range, 14-27 months) were included. The mean age was 60.3 years. RESULTS All FAOS subscales showed pre- to postoperative improvements, but there was no statistical significance in all subscales. The mean VAS score showed improvement from 4.1 to 3.0 (P = .012). On postoperative plain radiographs, implant subsidence was observed 60% (6/10) at 4 weeks after surgery and 90% (9/10) at the final follow-up. Fifty percent (5/10) showed radiologic lucency around the implant. Forty percent (4/10) had erosion of the proximal phalanx of the great toe. Four patients (36%) reported no improvement following surgery at the final follow-up, which were considered as failures. Three patients required additional surgery related to the implants. An additional patient is waiting to revise the implant. CONCLUSION Our current cohort study demonstrated a high failure rate with the polyvinyl alcohol hydrogel implant in patients with hallux rigidus. Significant radiologic subsidence with lysis around the implant, erosion of the proximal phalanx countersurface, and implant wear are harbingers for concern in the long term. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
| | - Eoghan T Hurley
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA
| | - John G Kennedy
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA
| |
Collapse
|
16
|
Chrea B, Eble SK, Day J, Ellis SJ, Drakos MC. Comparison Between Polyvinyl Alcohol Implant and Cheilectomy With Moberg Osteotomy for Hallux Rigidus. Foot Ankle Int 2020; 41:1031-1040. [PMID: 32723096 DOI: 10.1177/1071100720947380] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND In 2016, the US Food and Drug Administration (FDA) approved the use of a polyvinyl alcohol (PVA) hydrogel implant for the surgical management of hallux rigidus. Though recent studies have evaluated the safety and efficacy of the implant, no study has compared outcomes following PVA implantation with those following traditional joint-preserving procedures for hallux rigidus, such as cheilectomy with Moberg osteotomy. The purpose of this study was to compare clinical and patient-reported outcomes for patients undergoing cheilectomy and Moberg osteotomy, with or without PVA implant, at a single multisurgeon academic center. Our hypothesis was that the addition of the PVA implant would result in superior clinical and patient-reported outcomes. METHODS In total, 166 patients were identified who underwent cheilectomy and Moberg osteotomy with (PVACM; n = 72) or without (CM; n = 94) a PVA implant between January 2016 and December 2018 by 1 of 8 foot and ankle fellowship-trained orthopedic surgeons at our institution. Of these patients, 60 PVACM and 73 CM patients had both baseline and minimum 1-year postoperative Patient-Reported Outcomes Measurement Information System (PROMIS) scores. The average time to survey follow-up was 14.5 months for PVACM patients and 15.6 months for CM patients. Retrospective chart review was performed to assess the incidence of postoperative complications and reoperations, with an average clinical follow-up of 27.7 (range, 16.0-46.4) months for PVACM patients and 36.6 (range, 18.6-47.8) months for CM patients. RESULTS Both PVACM and CM cohorts demonstrated significant improvement in the PROMIS Physical Function, Pain Interference, Pain Intensity, and Global Physical Health domains when comparing preoperative and postoperative scores within each group (P < .01). When comparing scores between the PVACM and CM cohorts, preoperative scores were similar, while CM patients demonstrated significantly higher postoperative Physical Function (51.8 ± 8.7 vs 48.8 ± 8.0; P = .04) and significantly lower Pain Intensity (39.9 ± 8.3 vs 43.4 ± 8.7; P = .02) scores. The pre- to postoperative change in Physical Function was also significantly greater for CM patients (7.1 ± 8.5 vs 3.6 ± 6.2; P = .011). In the PVACM group, there were 3 revisions (5%), 1 reimplantation, 1 conversion to arthrodesis, and 1 revision to correct hyperdorsiflexion. In the CM group, there was 1 revision (1.4%), a conversion to arthrodesis (P = .21). Other postoperative complications included persistent pain (7 out of 60 PVACM patients [11.7%] and 8 out of 73 CM patients [11.0%]; P = .90) and infection in 3 PVACM patients (5%) and no CM patients (P = .05). CONCLUSION Though our results generally support the safety and utility of the PVA implant as previously established by the clinical trial, at 1 to 2 years of follow-up, CM without a PVA implant may provide equivalent or better relief compared with a PVACM procedure, while avoiding potential risks associated with the implant. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
Affiliation(s)
- Bopha Chrea
- Hospital for Special Surgery, New York, NY, USA
| | | | | | | | | | -
- Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
17
|
Eble SK, Hansen OB, Chrea B, Cabe TN, Garfinkel J, Drakos MC. Clinical Outcomes of the Polyvinyl Alcohol (PVA) Hydrogel Implant for Hallux Rigidus. Foot Ankle Int 2020; 41:1056-1064. [PMID: 32646235 PMCID: PMC7549279 DOI: 10.1177/1071100720932526] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Hallux rigidus is a common arthritic condition that has been addressed surgically with a range of techniques, from an isolated cheilectomy to first metatarsophalangeal (MTP) joint fusion. Recently, hemiarthroplasty with polyvinyl alcohol (PVA) hydrogel implant has been used as an alternative treatment to relieve pain while preserving motion of the first MTP joint. We retrospectively reviewed patient-reported outcome scores and clinical outcomes for patients treated for hallux rigidus with PVA hydrogel implant at an academic, multisurgeon center. METHODS A total of 103 patients who underwent first MTP hemiarthroplasty with PVA hydrogel implant between January 2017 and October 2018 were retrospectively reviewed (average, 26.2 months). Eight surgeons were represented. Baseline Patient-Reported Outcomes Measurement Information System (PROMIS) scores for the Physical Function, Pain Interference, Pain Intensity, Global Physical Health, Global Mental Health, and Depression domains were collected prospectively and compared with PROMIS scores collected at a minimum of 1 year postoperatively (average, 13.9 months). Seventy-three patients had both preoperative and postoperative scores. Ten of these patients had undergone a prior procedure of the first MTP, and 52 underwent concurrent Moberg osteotomy at the time of PVA hydrogel implantation. RESULTS For patients with baseline and postoperative PROMIS scores, significant pre- to postoperative improvement was detected for the Physical Function, Pain Interference, Pain Intensity, and Global Physical Health domains (P < .05). Patients who had undergone a prior procedure of the first MTP had significantly higher postoperative Pain Intensity scores compared with those who did not undergo a prior procedure. Patients undergoing concurrent Moberg osteotomy had significantly lower postoperative Pain Interference and Pain Intensity scores compared with those who did not undergo a Moberg. Two patients underwent revision procedures in the first 2 years postoperatively, one with revision hemiarthroplasty and one with conversion to arthrodesis. CONCLUSION On average across our entire cohort, physical function and pain scores improved significantly pre- to postoperatively; however, postoperative pain scores were significantly higher for patients who had undergone a prior procedure of the first MTP and significantly lower for patients who underwent concurrent Moberg osteotomy. The implant displayed excellent survivorship in the first 2 years postoperatively, with only 2 revision procedures. LEVEL OF EVIDENCE Level III, comparative series.
Collapse
Affiliation(s)
| | | | - Bopha Chrea
- Hospital for Special Surgery, New York,
NY, USA
| | | | | | | | | |
Collapse
|
18
|
Fogleman J, Robles A, Hollyfield J, Whitlow S, Lundeen GA. Failed Hydrogel Synthetic Cartilage Implant With Osteolytic Cyst Formation in the First Metatarsophalangeal Joint. FOOT & ANKLE ORTHOPAEDICS 2020; 5:2473011420934384. [PMID: 35097394 PMCID: PMC8697190 DOI: 10.1177/2473011420934384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Affiliation(s)
| | - Abrianna Robles
- University of Nevada, Reno, School of Medicine, Reno, NV, USA
| | | | | | | |
Collapse
|
19
|
Thordarson DB, Cassinelli SJ, Charlton TP, Chen S. Response to "Letter Regarding: Early Outcomes and Complications of Synthetic Cartilage Implant for Treatment of Hallux Rigidus in the United States". Foot Ankle Int 2019; 40:1152-1153. [PMID: 31600477 DOI: 10.1177/1071100719878413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|