1
|
Richter A, Stukenborg-Colsman C, Plaass C. SPECT/CT of Total Ankle Arthroplasty. Clin Podiatr Med Surg 2024; 41:649-663. [PMID: 39237177 DOI: 10.1016/j.cpm.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
Use of SPECT/CT (Single Photon Emission Computed Tomography/Computed Tomography) is increasing providing additional information in patients with inconclusive clinical examination and unremarkable imaging findings presenting with chronic pain after total ankle arthroplasty. To differentiate the cause of pain after total ankle arthroplasty can be challenging. SPECT/CT combines structural and metabolic imaging as a hybrid tool leading to higher specificity and overall diagnostic accuracy presumably in cases of gutter impingement, prosthetic loosening, and osteoarthritis of adjacent joints. Moreover, SPECT/CT can complement diagnostic work up in periprosthetic joint infections. Basal tracer enhancement has to be considered for the interpretation of imaging findings.
Collapse
Affiliation(s)
- Alena Richter
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany
| | - Christina Stukenborg-Colsman
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany
| | - Christian Plaass
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany.
| |
Collapse
|
2
|
de Carvalho KAM, Barbachan Mansur NS, DaCosta A, Godoy-Santos AL, de Cesar Netto C. Cone-Beam Weight-Bearing Computed Tomography of Ankle Arthritis and Total Ankle Arthroplasty. Clin Podiatr Med Surg 2024; 41:665-684. [PMID: 39237178 DOI: 10.1016/j.cpm.2024.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
Weight-bearing computed tomography has multiple advantages in evaluating the hindfoot and ankle. It can assess hindfoot and ankle alignment, pathology in ankle arthritis, and complications related to total ankle replacements. It is an essential tool in ankle osteoarthritis diagnostic, preoperative planning, and total ankle replacement outcomes. It allows for better accuracy and reproducibility of alignment and implant size. In addition, it has the potential to more assertively detect complications related to weight bearing.
Collapse
Affiliation(s)
| | | | - Albert DaCosta
- Department of Orthopedic Surgery (IOT), Division of Foot and Ankle, University of São Paulo (USP), São Paulo-SP, Brazil
| | - Alexandre Leme Godoy-Santos
- Department of Orthopedic Surgery (IOT), Division of Foot and Ankle, University of São Paulo (USP), São Paulo-SP, Brazil
| | - Cesar de Cesar Netto
- Department of Orthopedic Surgery, Division of Foot and Ankle, Duke University, Durham-NC, USA.
| |
Collapse
|
3
|
Lewis TL, Walker R, Alkhalfan Y, Latif A, Abbasian A. Custom Patient-Specific 3D-Printed Titanium Truss Tibiotalocalcaneal Arthrodesis Implants for Failed Total Ankle Replacements: Classification, Technical Tips, and Treatment Algorithm. Foot Ankle Int 2024; 45:950-961. [PMID: 38872312 DOI: 10.1177/10711007241255381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/15/2024]
Abstract
BACKGROUND The management of failed total ankle replacements, with significant loss of bone stock, is challenging with high rates of complications and associated morbidity. Recent technological advances have enabled the development of patient-customized 3D-printed titanium truss arthrodesis implants, which offer an alternative salvage option for failed total ankle replacements. METHODS A prospective observational study was performed of 6 cases of failed total ankle replacements that were managed using custom patient-specific 3D-printed titanium truss arthrodesis implants. Technical tips, classification, and a treatment algorithm were developed based on our initial experience. RESULTS Between November 2018 and March 2022, 6 patients underwent arthrodesis for failed total ankle replacements. Follow-up was available for all cases. The mean follow-up was 3.0 years (range 1-4.5). The mean MOXFQ Index improved from 73.1 to 32.3 (P < .05). The mean EQ-5D-5L Index improved from 0.366 to 0.743 (P < .05) and the EQ-VAS also improved from 53.0 to 63.3 (P = .36). The mean VAS-Pain score at final follow-up was 27.5. There were no cases of nonunion. None of the patients were smokers. The overall complication rate was 50%. Two patients returned to surgery: one for wound washout following TAR explantation and a second for removal of metalwork 2 years following surgery for a prosthetic joint infection secondary to hematogenous spread. No patients underwent revision fixation or amputation. CONCLUSION Custom patient-specific 3D-printed titanium truss arthrodesis implants are a viable treatment option for failed total ankle replacements.
Collapse
Affiliation(s)
- Thomas L Lewis
- Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Roland Walker
- Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Yousif Alkhalfan
- Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Ahmed Latif
- Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Ali Abbasian
- Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
4
|
Henry JK, Teehan E, Deland J, Ellis SJ, Demetracopoulos C. Lessons From Revision Total Ankle Replacement: Tibias Fail Earlier, and Taluses Fail Later (and Fail Again). Foot Ankle Int 2024; 45:993-999. [PMID: 38798096 DOI: 10.1177/10711007241255112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
BACKGROUND The literature on survivorship and outcomes after revision total ankle replacement (TAR) in the modern era is limited. This study aimed to describe the timing to revision and survivorship after revision TAR. We hypothesized that tibial-sided failures would occur earlier after the primary TAR, and secondary revisions after failure of revision TAR would occur more due to talar-sided failures than tibial-sided failures. METHODS This is a single-institution retrospective study of TAR patients with minimum 2-year follow-up. Revision TARs (defined as exchange of tibial and/or talar components) for aseptic causes with any implant were included. Etiology of failure necessitating revision and ultimate outcomes after revision (survival of TAR revision, additional revision, conversion to fusion, and below-knee amputation [BKA]) were recorded. RESULTS There were 46 revision TARs, with mean age of 60.6 (range: 31-77) years and mean 3.5 years' follow-up postrevision. Revisions for tibial failure occurred significantly earlier (n = 22, 1.3 ± 0.5 years after index procedure) than those for talar failure (n = 19, 2.3 ± 1.7 years after index procedure) or combined tibial-talar failure (n = 5, 3.4 ± 3.4 years after index procedure) (P = .015). Revisions for tibial-only failure had better survival (95.5%) than revisions for talar or combined tibial-talar failures: 26% of talar failures and 20% of combined tibial-talar failures underwent ≥1 revisions. Of the 6 additional revisions after failure of the talar component, 1 ultimately underwent BKA, 2 were converted to total talus replacement, 2 were revised to modular augmented talar components, and 1 was treated with explant and cement spacer for PJI after the revision. CONCLUSION TAR tibial failures occurred earlier than talar failures or combined tibial-talar failures. Revisions for talar failures and combined tibial-talar failures were more likely to require additional revision or ultimately fail revision treatment. This is important given the consequences of talar implant subsidence, bone necrosis, loss of bone stock, and limited salvage options.
Collapse
Affiliation(s)
- Jensen K Henry
- Foot & Ankle Department, Hospital for Special Surgery, New York, NY, USA
| | - Emily Teehan
- Foot & Ankle Department, Hospital for Special Surgery, New York, NY, USA
| | - Jonathan Deland
- Foot & Ankle Department, Hospital for Special Surgery, New York, NY, USA
| | - Scott J Ellis
- Foot & Ankle Department, Hospital for Special Surgery, New York, NY, USA
| | | |
Collapse
|
5
|
Palma J, Shaffrey I, Kim J, Cororaton A, Henry J, Ellis SJ, Demetracopoulos CA. Postoperative Medial Malleolar Fractures in Total Ankle Replacement Are Associated With Decreased Medial Malleolar Width and Varus Malalignment: A Case-Control Study. Foot Ankle Int 2024; 45:1009-1017. [PMID: 38912602 DOI: 10.1177/10711007241258167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/25/2024]
Abstract
BACKGROUND There are limited data regarding risk factors associated with periprosthetic medial malleolar fractures in total ankle arthroplasty (TAA). This case-control study aimed to identify the risk factors and analyze the effect of prophylactic screw fixation in preventing a medial malleolar fracture after TAA. METHODS A case-control study was conducted on 149 patients who underwent primary TAA. Twenty patients with postoperative medial malleolar fractures >4 weeks postoperatively (cases) were identified. An additional 129 patients (controls) were randomly selected from the TAA database. Radiographic evaluation included tibial component coronal alignment and postoperative medial malleolar width. Demographics and radiographic variables were compared between cohorts. Logistic regression was used to investigate the association between medial malleolar fracture and postoperative coronal alignment, medial malleolar width, and prophylactic fixation of the medial malleolus. RESULTS Mean (SD) medial malleolar width was significantly smaller in the fracture cohort (8.52 mm [1.6]) than in the control group (11.78 mm [1.74]) (P < .001). Mean (SD) tibial component coronal alignment was 92.17 degrees (2.77) in the fracture cohort and 90.21 degrees (1.66) in the control group (P = .002). Regression analysis identified a significant negative association between postoperative medial malleolar width and the probability of fracture (OR = 0.06, 95% CI 0.01, 0.26, P < .001). Varus malalignment of the tibial component was positively associated with the probability of fracture (OR = 1.90, 95% CI 1.27, 2.86, P = .002). Prophylactic screw fixation resulted in more than 90% reduction in the odds of a fracture (OR = 0.04, 95% CI 0.01, 0.45, P = .01). ROC curve analysis determined a medial malleolar width of 10.3 mm as a potential threshold for predicting fracture. CONCLUSION Decreased medial malleolar width and postoperative varus malalignment were associated with an increased risk of postoperative medial malleolar fracture. Therefore, surgeons should consider prophylactic screw fixation in patients with a medial malleolar width <10.3 mm or at risk of postoperative varus deformity.
Collapse
Affiliation(s)
- Joaquin Palma
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA
- Department of Orthopaedic Surgery, School of Medicine, Pontificia Universidad Catolica de Chile, Santiago, Santiago Metropolitan Region, Chile
| | - Isabel Shaffrey
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Jaeyoung Kim
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Agnes Cororaton
- Biostatistics Core, Hospital for Special Surgery, New York, NY, USA
| | - Jensen Henry
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Scott J Ellis
- Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | | |
Collapse
|
6
|
Lee MS, Lee GW, Lee KB. Bone grafting for periprosthetic bone cysts following total ankle arthroplasty. Bone Joint J 2024; 106-B:475-481. [PMID: 38688515 DOI: 10.1302/0301-620x.106b5.bjj-2023-1091.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
Aims The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan. Methods We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured. Results Out of 37 ankles, graft incorporation was successful in 30 cases. Among the remaining seven cases, four (10.8%) exhibited cyst re-progression, so secondary bone grafting was needed. After secondary bone grafting, no further progression has been noted, resulting in an overall 91.9% success rate (34 of 37) at a mean follow-up period of 47.5 months (24 to 120). The remaining three cases (8.1%) showed implant loosening, so tibiotalocalcaneal arthrodesis was performed. Functional outcomes were also improved after bone grafting in all variables at the latest follow-up (p < 0.05). The mean incorporation rate of the grafts according to the location of the cysts was 84.8% (55.2% to 96.1%) at the medial malleolus, 65.1% (27.6% to 97.1%) at the tibia, and 81.2% (42.8% to 98.7%) at the talus. Smoking was identified as a significant predisposing factor adversely affecting graft incorporation (p = 0.001). Conclusion Bone grafting for periprosthetic bone cysts following primary TAA is a reliable procedure with a satisfactory success rate and functional outcomes. Regular follow-up, including CT scan, is important for the detection of cyst re-progression to prevent implant loosening after bone grafting.
Collapse
Affiliation(s)
- Min-Su Lee
- Department of Orthopedic Surgery, Chonnam National University Medical School and Hospital, Gwangju, South Korea
| | - Gun-Woo Lee
- Department of Orthopedic Surgery, Chonnam National University Medical School and Hospital, Gwangju, South Korea
| | - Keun-Bae Lee
- Department of Orthopedic Surgery, Chonnam National University Medical School and Hospital, Gwangju, South Korea
| |
Collapse
|
7
|
Ferrao PNF, Saragas NP, Naude JJ. Outcomes of Total Ankle Arthroplasty After Periprosthetic Cyst Curettage and Bone Grafting. Foot Ankle Clin 2024; 29:123-143. [PMID: 38309797 DOI: 10.1016/j.fcl.2023.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2024]
Abstract
Total ankle arthroplasty (TAA) has become a popular management option for ankle arthritis. Periprosthetic osteolysis is one of the most common causes for reoperation in TAA. A CT scan should be done in all suspected osteolysis cases to confirm location, quantify size and aid in surgical planning. These patients are often asymptomatic with limited evidence regarding appropriate management. Smaller lesions should be monitored for progression in size. Periprosthetic cysts measuring 10-15mm in all three axes should be considered for debridment and curettage with autogenous bone grafting. The authors believe that bone grafting of large asymptomatic periprosthetic cysts could prevent implant failure.
Collapse
Affiliation(s)
- Paulo N F Ferrao
- The Orthopaedic Foot & Ankle Unit, Netcare Linksfield Hospital, 303 Linksfield Medical Centre, 24 12th Avenue, Linksfield West, 2192, South Africa; Department of Orthopaedic Surgery, University of the Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193, South Africa.
| | - Nikiforos P Saragas
- The Orthopaedic Foot & Ankle Unit, Netcare Linksfield Hospital, 303 Linksfield Medical Centre, 24 12th Avenue, Linksfield West, 2192, South Africa; Department of Orthopaedic Surgery, University of the Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193, South Africa
| | - Jaco J Naude
- The Orthopaedic Foot & Ankle Unit, Netcare Linksfield Hospital, 303 Linksfield Medical Centre, 24 12th Avenue, Linksfield West, 2192, South Africa; Life Wilgers Hospital, Denneboom road, Wilgers ext 14, Pretoria, 0040, South Africa
| |
Collapse
|
8
|
Henry JK, Shaffrey I, Wishman M, Palma Munita J, Zhu J, Cody E, Ellis S, Deland J, Demetracopoulos C. Early outcomes of the Exactech Vantage fixed-bearing total ankle replacement. Bone Joint J 2023; 105-B:1099-1107. [PMID: 37777206 DOI: 10.1302/0301-620x.105b10.bjj-2023-0173.r2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/02/2023]
Abstract
Aims The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. Methods This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years' follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes. Results There were 168 patients (171 ankles) included with a mean follow-up of 2.81 years (2 to 4.6) and mean age of 63.0 years (SD 9.4). Of the ten ankles with implant failure (5.8%), six had loosening of the tibial component. In the remaining four failed implants, one was due to periprosthetic joint infection (PJI), one was due to loosening of the talar component, and two were due to loosening of both the tibial and talar components. Seven patients underwent reoperation: irrigation and debridement for superficial infection (n = 4); bone grafting for cysts (n = 2); and open reduction internal fixation (n = 1). Asymptomatic peri-implant lucency/subsidence occurred in 20.1% of ankles, with the majority involving the tibial component (n = 25). There were statistically significant improvements in PROMs in all domains. Conclusion Short-term results of this implant demonstrate early survival comparable to the reported survivorship of similar low-profile, non-stemmed implants. Radiological lucency occurred more commonly at the tibial component, and revisions occurred primarily due to loosening of the tibial component. Further research is needed to evaluate longer-term survivorship.
Collapse
Affiliation(s)
- Jensen K Henry
- Foot and Ankle Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Isabel Shaffrey
- Foot and Ankle Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Mark Wishman
- Weill Cornell Medical College, New York, New York, USA
| | - Joaquín Palma Munita
- Foot and Ankle Surgery, Hospital for Special Surgery, New York, New York, USA
- Department of Orthopedic Surgery, Hospital Sótero del Río, Santiago, Brazil
| | - Jiaqi Zhu
- Foot and Ankle Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Elizabeth Cody
- Foot and Ankle Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Scott Ellis
- Foot and Ankle Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Jonathan Deland
- Foot and Ankle Surgery, Hospital for Special Surgery, New York, New York, USA
| | | |
Collapse
|
9
|
Richter A, Stukenborg-Colsman C, Plaass C. SPECT/CT of Total Ankle Arthroplasty. Foot Ankle Clin 2023; 28:493-507. [PMID: 37536815 DOI: 10.1016/j.fcl.2023.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Use of SPECT/CT (Single Photon Emission Computed Tomography/Computed Tomography) is increasing providing additional information in patients with inconclusive clinical examination and unremarkable imaging findings presenting with chronic pain after total ankle arthroplasty. To differentiate the cause of pain after total ankle arthroplasty can be challenging. SPECT/CT combines structural and metabolic imaging as a hybrid tool leading to higher specificity and overall diagnostic accuracy presumably in cases of gutter impingement, prosthetic loosening, and osteoarthritis of adjacent joints. Moreover, SPECT/CT can complement diagnostic work up in periprosthetic joint infections. Basal tracer enhancement has to be considered for the interpretation of imaging findings.
Collapse
Affiliation(s)
- Alena Richter
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany
| | - Christina Stukenborg-Colsman
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany
| | - Christian Plaass
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany.
| |
Collapse
|
10
|
de Carvalho KAM, Barbachan Mansur NS, de Cesar Netto C. Cone-Beam Weight-Bearing Computed Tomography of Ankle Arthritis and Total Ankle Arthroplasty. Foot Ankle Clin 2023; 28:509-528. [PMID: 37536816 DOI: 10.1016/j.fcl.2023.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Weight-bearing computed tomography has multiple advantages in evaluating the hindfoot and ankle. It can assess hindfoot and ankle alignment, pathology in ankle arthritis, and complications related to total ankle replacements. It is an essential tool in ankle osteoarthritis diagnostic, preoperative planning, and total ankle replacement outcomes. It allows for better accuracy and reproducibility of alignment and implant size. In addition, it has the potential to more assertively detect complications related to weight bearing.
Collapse
Affiliation(s)
| | | | - Cesar de Cesar Netto
- Department of Orthopedics and Rehabilitation, University of Iowa, Carver College of Medicine, Iowa City, IA, USA; Department of Orthopedic Surgery, Division of Orthopedic Foot and Ankle Surgery, Duke University, Durham, NC, USA.
| |
Collapse
|
11
|
Hur ES, Mehta N, Lee S, Bohl DD. Management of Periprosthetic Bone Cysts After Total Ankle Arthroplasty. Orthop Clin North Am 2023; 54:109-119. [PMID: 36402507 DOI: 10.1016/j.ocl.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Modern improvements in total ankle arthroplasty (TAA) have increased the performance of this procedure for treatment of end-stage ankle arthritis. A common finding after TAA is the formation of periprosthetic bone cysts, which can be clinically silent or result in TAA failure. The exact cause of periprosthetic bones cysts has not been established, but major theories are related to osteolysis secondary to implant wear, micromotion, and stress shielding. Treatment can be nonoperative with clinical observation for small, asymptomatic cysts. Large, progressive, and symptomatic cysts often merit surgical treatment with debridement and grafting, revision TAA, or salvage arthrodesis.
Collapse
Affiliation(s)
- Edward S Hur
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W. Harrison Street, Suite 400, Chicago, IL 60612, USA
| | - Nabil Mehta
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W. Harrison Street, Suite 400, Chicago, IL 60612, USA
| | - Simon Lee
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W. Harrison Street, Suite 400, Chicago, IL 60612, USA
| | - Daniel D Bohl
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W. Harrison Street, Suite 400, Chicago, IL 60612, USA.
| |
Collapse
|
12
|
Conti MS, Irwin TA, Ford SE, Jones CP, Anderson RB, Davis WH. Complications, Reoperations, and Patient-Reported Outcomes Following a 2-Stage Revision Total Ankle Arthroplasty for Chronic Periprosthetic Joint Infections. Foot Ankle Int 2022; 43:1614-1621. [PMID: 36367126 DOI: 10.1177/10711007221133398] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND As total ankle arthroplasty (TAA) becomes more common, chronic periprosthetic joint infections (PJIs) will be encountered more frequently. No studies have reported on patient-reported outcomes following a 2-stage revision procedure for a chronic PJI after a TAA. The primary purpose of this study was to investigate postoperative clinical outcomes at a minimum of 2 years following a 2-stage revision TAA for chronic PJI. METHODS Patients who underwent a 2-stage revision TAA for a chronic PJI (>4 weeks after a primary TAA) between January 2010 and December 2019 were eligible to be included in this study. Chronic PJI was defined as a sinus tract that directly communicated with the prosthesis or the same organism identified in ≥2 synovial fluid samples. Twelve patients were eligible to be included in this case series. One patient died prior to 2-year follow-up, which left 11 patients available for analysis. All 11 patients underwent reimplantation. The data were found not to be normally distributed; therefore, medians and interquartile ranges (IQRs) were reported. RESULTS At a median of 3.0 years (IQR 2.0-4.0 years) following the second stage of their revision arthroplasty, the median Foot and Ankle Ability Measure (FAAM) Activities of Daily Living and Sports scores were 60.7 (IQR 52.4, 79.8) and 31.3 (IQR 9.4, 40.6), respectively. At final follow-up, 10 patients (90.9%) were ambulating with a TAA in place. Seven patients (63.6%) required a reoperation including 1 patient who underwent a below-knee amputation. CONCLUSION Our study suggests that a 2-stage revision TAA may be an option for patients with a chronic PJI. However, patients who undergo a 2-stage revision TAA for a chronic PJI have lower than previously published 2-year FAAM scores and a high rate of reoperation. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
| | - Todd A Irwin
- OrthoCarolina Foot & Ankle Institute, Charlotte, NC, USA
| | - Samuel E Ford
- OrthoCarolina Foot & Ankle Institute, Charlotte, NC, USA
| | | | - Robert B Anderson
- Bellin Health Titletown Sports Medicine & Orthopedics, Green Bay, WI, USA
| | - W Hodges Davis
- OrthoCarolina Foot & Ankle Institute, Charlotte, NC, USA
| |
Collapse
|
13
|
Kim J, Rajan L, Fuller R, O'Malley M, Levine D, Deland J, Ellis S, Demetracopoulos C. Mid-term functional outcomes following reoperation after total ankle arthroplasty: A retrospective cohort study. Foot Ankle Surg 2022; 28:1463-1467. [PMID: 36088242 DOI: 10.1016/j.fas.2022.08.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 05/23/2022] [Accepted: 08/31/2022] [Indexed: 02/04/2023]
Abstract
BACKGROUND Despite a significant reported rate of non-revision reoperation after total ankle arthroplasty (TAA), it is uncertain if these subsequent procedures have an impact on the longer term outcomes. This study aimed to compare minimum five-year functional outcomes of patients who had undergone reoperation after TAA to those who did not require reoperation. METHODS Seventy-six ankles (74 patients) who underwent TAA with the Salto Talaris fixed bearing system between 2007 and 2014 were allocated into two groups based on presence (n = 16) or absence of reoperation (n = 60). Reoperations included all secondary procedures after index TAA, excluding revision surgeries requiring removal or exchange of the original prosthesis. The foot and ankle outcome score (FAOS) at preoperative and minimum five-year follow-up was compared between the groups. Additionally, improvements in FAOS subscales were compared. Preoperative deformity, postoperative implant alignment, number of periprosthetic cysts, and subsidence between groups were compared using standard weightbearing radiographs. RESULTS The most common cause of reoperation was gutter impingement (n = 11), followed by stress fracture of the medial malleolus (n = 2), tarsal tunnel syndrome (n = 1), periprosthetic cyst (n = 1), and infection (n = 1). In comparison to the non-reoperation group, all FAOS subscales except for the Sports and Recreational Activities subscale were significantly lower in the reoperation group at final follow-up. The reoperation group exhibited significantly less improvement in the Pain, Symptoms, and Quality of Life subscales at final follow-up (p < 0.05). There were no statistical differences in the radiographic parameters between both groups. CONCLUSIONS Patients who underwent reoperation after TAA demonstrated inferior functional outcomes at mid-term follow-up. An emphasis should be placed on preventing possible causes of reoperations to achieve favorable patient outcomes. Additionally, if a reoperation is deemed necessary, a thorough evaluation and surgical correction of underlying causes should be achieved.
Collapse
Affiliation(s)
- Jaeyoung Kim
- Hospital for Special Surgery, 532 East 72nd Street, 5th Floor, New York, NY 10021, United States.
| | - Lavan Rajan
- Hospital for Special Surgery, 532 East 72nd Street, 5th Floor, New York, NY 10021, United States.
| | - Robert Fuller
- Hospital for Special Surgery, 532 East 72nd Street, 5th Floor, New York, NY 10021, United States.
| | - Martin O'Malley
- Hospital for Special Surgery, 532 East 72nd Street, 5th Floor, New York, NY 10021, United States.
| | - David Levine
- Hospital for Special Surgery, 420 E 72nd St Ground Floor, New York, NY 10021, United States.
| | - Jonathan Deland
- Hospital for Special Surgery, 532 East 72nd Street, 5th Floor, New York, NY 10021, United States.
| | - Scott Ellis
- Hospital for Special Surgery, 532 East 72nd Street, 5th Floor, New York, NY 10021, United States.
| | | |
Collapse
|
14
|
Hermus JP, Voesenek JA, van Gansewinkel EHE, Witlox MA, Poeze M, Arts JJ. Complications following total ankle arthroplasty: A systematic literature review and meta-analysis. Foot Ankle Surg 2022; 28:1183-1193. [PMID: 35872118 DOI: 10.1016/j.fas.2022.07.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 06/25/2022] [Accepted: 07/04/2022] [Indexed: 02/04/2023]
Abstract
BACKGROUND Total ankle arthroplasty (TAA) is increasingly used as a treatment for end-stage ankle arthropathy. However, TAA may be more sensitive to complications, failure and subsequent re-operations compared to ankle arthrodesis. The aim of this systematic review and meta-analysis is to generate an overview of complications of TAA surgery. METHODS PubMed, EMBASE and the Cochrane library were searched between 2000 and 2020 to identify all papers reporting on complications in TAA surgery. Meta-analysis was conducted based on type of complication in TAA surgery. Pooled estimates of complications were calculated using a random effects model. Risk of bias and quality was assessed using the Cochrane risk of bias and ROBINS-I tools. The confidence in estimates was rated and described according to the recommendations of the GRADE working group. RESULTS One hundred twenty-seven studies were included in this systematic review. All combined, they reported on 16.964 TAAs with an average follow-up of 47.99 ± 29.18 months. Complications with highest reported pooled incidence were intra-operative fracture 0.06 (95 %CI 0.04-0.08) (GRADE Very low) and impingement 0.06 (95 %CI 0.04-0.08) (GRADE low) respectively. CONCLUSION Reported complication incidence of TAA surgery is still high and remains a significant clinical problem that can be severely hampering long-term clinical survival of the prosthesis. The results of this systematic review and meta-analysis can help guide surgeons in informing their patient about complication risks. Implementation of more stringent patient selection criteria might contribute to diminishing TAA complication rates.
Collapse
Affiliation(s)
- J P Hermus
- Department of Orthopaedic Surgery, Research School CAPHRI, Maastricht University Medical Center+, the Netherlands.
| | - J A Voesenek
- Department of Orthopaedic Surgery, Research School CAPHRI, Maastricht University Medical Center+, the Netherlands
| | - E H E van Gansewinkel
- Department of Orthopaedic Surgery, Research School CAPHRI, Maastricht University Medical Center+, the Netherlands
| | - M A Witlox
- Department of Orthopaedic Surgery, Research School CAPHRI, Maastricht University Medical Center+, the Netherlands
| | - M Poeze
- Department of Traumasurgery, Research School CAPHRI, Maastricht University Medical Center+, the Netherlands
| | - J J Arts
- Department of Orthopaedic Surgery, Research School CAPHRI, Maastricht University Medical Center+, the Netherlands
| |
Collapse
|
15
|
Heisler L, Vach W, Katz G, Egelhof T, Knupp M. Patient-Specific Instrumentation vs Standard Referencing in Total Ankle Arthroplasty: A Comparison of the Radiologic Outcome. Foot Ankle Int 2022; 43:741-749. [PMID: 35209725 PMCID: PMC9168897 DOI: 10.1177/10711007221077100] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Existing literature on the superiority of patient-specific instrumentation (PSI) in total ankle arthroplasty (TAA) over standard referencing (SR) is limited. Advantages presented include better implant alignment, shorter operating times, and increased accuracy of implant size prediction. The aim of this retrospective study was to analyze PSI in the hands of an experienced foot and ankle surgeon new to both PSI and SR for this specific implant, in regard to determining implant alignment, operative times, and radiologic short-term outcome and predicting implant size for tibial and talar components. METHODS Twenty-four patients undergoing TAA using PSI were compared to 25 patients using SR instrumentation. Outcome measures included alignment of the tibial component (α coronal plane, γ sagittal plane), the tibiotalar tilt (β), and the talar offset x on the sagittal view as well as the presence of radiolucent lines, operation time, and wound healing. Postoperative outcome was assessed at 6 weeks, 4 months, and 1 year postoperatively. RESULTS Implant positioning was similar in both groups, and no advantage in regard to the operative time could be seen when comparing TAA using PSI to SR. Implant size prediction was more reliable for the tibia than for the talus. Three patients (1 from the SR group and 2 from the PSI group) showed radiolucent lines around the tibial component. Two patients (both SR group) suffered delayed wound healing, albeit not requiring any additional measures. CONCLUSION The PSI method did not show an advantage over SR in regard to positioning of the components or the duration of the surgery. The current study suggests that no initial advantage of PSI over SR are to be expected in standard total ankle replacement. LEVEL OF EVIDENCE Level III, retrospective study.
Collapse
Affiliation(s)
| | - Werner Vach
- Basel Academy for Quality and Research
in Medicine, Basel, Switzerland
| | - Georg Katz
- Merian Iselin Klinik, Institute for
Radiology, Basel, Switzerland
| | - Thomas Egelhof
- Merian Iselin Klinik, Institute for
Radiology, Basel, Switzerland
| | - Markus Knupp
- University of Basel, Basel,
Switzerland,Orthopedic Surgery & Traumatology,
Mein Fusszentrum AG, Basel, Switzerland,Markus Knupp, MD, Specialist in Orthopedic
Surgery & Traumatology, Mein Fusszentrum AG, Eichenstrasse 31, Basel CH
4054, Switzerland.
| |
Collapse
|