1
|
Konopińska J, Gołaszewska K, Saeed E. Minimally invasive bleb surgery versus minimally invasive glaucoma surgery: a 12-month retrospective study. Sci Rep 2024; 14:12850. [PMID: 38834618 DOI: 10.1038/s41598-024-61811-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 05/09/2024] [Indexed: 06/06/2024] Open
Abstract
This study aimed to compare the IOP-lowering effectiveness and safety of standalone Preserflo MicroShunt and iStent 1st generation implantation combined with phacoemulsification in Caucasian patients with a 12-month follow-up period. This retrospective study analyzed the medical histories of patients undergoing antiglaucoma surgery at the Department of Ophthalmology, Medical University of Bialystok, between January 2019 and January 2022. The main outcome measures were success rates (complete: proportion of eyes with IOP < 18 mmHg (criterion A) and < 15 mmHg (criterion B) or 20% reduction in IOP without any glaucoma medication; qualified: proportion of eyes achieving IOPs < 18 mmHg and < 15 mmHg or 20% reduction in IOP from baseline with or without medications), mean reduction (%) in IOP, medication burden, number of complications and additional interventions. In both groups, a significant decrease in IOP and medication burden were observed at 6 and 12 months when compared with baseline. At 12 months, qualified surgical success in criterion A was recorded in 67.4% and 85.7% of patients in the Preserfo and iStent groups, respectively (p = 0.045). Complete surgical success in criterion B at 12 months accounted to 61.4% of patients from Prserflo group and 32.7% patients in iStent group (p = 0.04). Surgical failure at 12 months was documented in 30.2% and 6.3% of patients, respectively (p = 0.003). There was a significant difference between groups in %IOP reduction after 12 months. Greater reduction was observed in Preserflo group, MD = - 8.41 CI95 [- 15.88; - 0.95], p = 0.028, (- 33.49% ± 21.59 vs - 25.07% ± 14.15 in iStent group). Both procedures effectively reduced IOP and postoperative use of antiglaucoma medications in glaucoma patients.
Collapse
Affiliation(s)
- Joanna Konopińska
- Department of Ophthalmology, Medical University of Białystok, Białystok, Poland.
| | - Kinga Gołaszewska
- Department of Ophthalmology, Medical University of Białystok, Białystok, Poland
| | - Emil Saeed
- Department of Ophthalmology, Medical University of Białystok, Białystok, Poland
| |
Collapse
|
2
|
Yam GHF, Pi S, Du Y, Mehta JS. Posterior corneoscleral limbus: Architecture, stem cells, and clinical implications. Prog Retin Eye Res 2023; 96:101192. [PMID: 37392960 DOI: 10.1016/j.preteyeres.2023.101192] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 06/22/2023] [Accepted: 06/23/2023] [Indexed: 07/03/2023]
Abstract
The limbus is a transition from the cornea to conjunctiva and sclera. In human eyes, this thin strip has a rich variation of tissue structures and composition, typifying a change from scleral irregularity and opacity to corneal regularity and transparency; a variation from richly vascularized conjunctiva and sclera to avascular cornea; the neural passage and drainage of aqueous humor. The limbal stroma is enriched with circular fibres running parallel to the corneal circumference, giving its unique role in absorbing small pressure changes to maintain corneal curvature and refractivity. It contains specific niches housing different types of stem cells for the corneal epithelium, stromal keratocytes, corneal endothelium, and trabecular meshwork. This truly reflects the important roles of the limbus in ocular physiology, and the limbal functionality is crucial for corneal health and the entire visual system. Since the anterior limbus containing epithelial structures and limbal epithelial stem cells has been extensively reviewed, this article is focused on the posterior limbus. We have discussed the structural organization and cellular components of the region beneath the limbal epithelium, the characteristics of stem cell types: namely corneal stromal stem cells, endothelial progenitors and trabecular meshwork stem cells, and recent advances leading to the emergence of potential cell therapy options to replenish their respective mature cell types and to correct defects causing corneal abnormalities. We have reviewed different clinical disorders associated with defects of the posterior limbus and summarized the available preclinical and clinical evidence about the developing topic of cell-based therapy for corneal disorders.
Collapse
Affiliation(s)
- Gary Hin-Fai Yam
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; McGowan Institute for Regenerative Medicine, Pittsburgh, PA, USA.
| | - Shaohua Pi
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Yiqin Du
- Department of Ophthalmology, University of South Florida, Tampa, FL, USA
| | - Jodhbir S Mehta
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Program, Duke-National University of Singapore (NUS) Medical School, Singapore.
| |
Collapse
|
3
|
Feinberg L, Swampillai AJ, Byles D, Smith M. Six year outcomes of combined phacoemulsification surgery and endoscopic cyclophotocoagulation in refractory glaucoma. Graefes Arch Clin Exp Ophthalmol 2022; 261:1339-1347. [PMID: 36482212 DOI: 10.1007/s00417-022-05906-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 10/13/2022] [Accepted: 11/08/2022] [Indexed: 12/13/2022] Open
Abstract
PURPOSE This study is to describe the 6-year results of combined phacoemulsification surgery and endoscopic cyclophotocoagulation (Phaco-ECP) surgery in patients with uncontrolled glaucoma and no previous glaucoma surgery. METHODS This is a retrospective case series of 84 eyes. The primary outcome measure was intraocular pressure (IOP) reduction 6 years postoperatively. Secondary outcome measures were the cumulative probability of failure of the surgical procedure at 6 years. Failure was defined as IOP higher than 21 mm Hg or lower than 6 mm Hg or IOP not reduced by 20% from baseline at the 1, 2, 3, 4, 5, or 6-year time points or further laser or other surgery to reduce IOP at any timepoint. RESULTS There was a statistically significant decrease in mean IOP from 18.9 mmHg pre-operatively to 13.7, 12.8, 13.0, 12.7, 12.5, and 12.3 mmHg at the 1, 2, 3, 4, 5, and 6 years post-operatively respectively (p < 0.001). Fifty-seven (68%) reached criteria for failure by 6 years. In 36% of cases, this was due to inadequate IOP control, whereas 32% required further laser or surgery. When we excluded patients who only had selective laser trabeculoplasty rather than further surgery, the failure rate reduced to 51%. Eleven percent had a post-operative complication, 2.4% requiring further surgical intervention. CONCLUSIONS At 6 years postoperatively, combined phaco-ECP achieved a significant reduction in IOP in patients with uncontrolled glaucoma and no previous drainage surgery. Significant complications were uncommon, but 68% was classified as surgical failures by the six year point.
Collapse
Affiliation(s)
- Leo Feinberg
- West of England Eye Unit, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, EX2 5DW, Devon, UK.
| | - Andrew J Swampillai
- West of England Eye Unit, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, EX2 5DW, Devon, UK
| | - Daniel Byles
- West of England Eye Unit, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, EX2 5DW, Devon, UK
| | - Michael Smith
- West of England Eye Unit, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, EX2 5DW, Devon, UK
| |
Collapse
|
4
|
Baumgarten S, Plange N, Htoon HM, Lohmann T, Videa A, Koutsonas A, Schellhase H, Kuerten D, Walter P, Fuest M. Outcomes of combined single-use dual blade goniotomy and cataract surgery. Int Ophthalmol 2022; 42:2685-2696. [PMID: 35357642 PMCID: PMC9420088 DOI: 10.1007/s10792-022-02257-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Accepted: 03/12/2022] [Indexed: 11/26/2022]
Abstract
Purpose Single-use dual blade goniotomy (SBG) is a novel ab interno procedure that removes three to five clock hours of trabecular meshwork (TM). We analysed the reduction of intraocular pressure (IOP) and topical glaucoma medication (Meds) in eyes following combined cataract surgery and SBG (Cat-SBG).
Methods IOP and Meds were evaluated retrospectively in 55 eyes of 38 patients. 44 eyes had high tension glaucoma (HTG) and eleven eyes had normal tension glaucoma (NTG). Complete success (no Meds) and qualified success (with Meds) for IOP levels ≤ 21, ≤ 18 , ≤ 16 mmHg or ≥ 20% IOP reduction at the two- and six-month follow-up were evaluated.
Results IOP and Meds were significantly reduced from before to two months after Cat-SBG in HTG- and NTG-patients (HTG: IOP 19.4 ± 3.3 to 15.1 ± 3.3 mmHg; p < 0.001; Meds 2.1 ± 1.3 to 0.8 ± 1.3; p < 0.001; NTG: IOP 14.0 ± 2.3 to 11.5 ± 2.3 mmHg; p = 0.004; Meds 1.6 ± 0.7 to 0.3 ± 0.7; p < 0.001). IOP and Meds did not change significantly from two to six months after Cat-SBG. In HTG, complete and qualified success rates were 43% (19/44) and 93% (41/44) for IOP ≤ 18 mmHg, 36% (16/44) and 64% (28/44) for IOP ≤ 16 mmHg and 30% (13/44) and 43% (19/44) for ≥ 20% IOP reduction six months after surgery. In NTG, complete and qualified success was 81% (9/11) and 100% (11/11) for IOP ≤ 18 and ≤ 16 mmHg, and 27% (3/11) for IOP reduction ≥ 20%. IOP and Meds reduction were comparable between HTG and NTG eyes. Only minor postoperative complications occurred. Conclusion Cat-SBG is an efficient method to significantly lower IOP in patients with HTG and NTG.
Collapse
Affiliation(s)
- Sabine Baumgarten
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany.
| | - Niklas Plange
- Augenzentrum Am Annapark, Steigerweg 3, 52477, Alsdorf, Germany
| | - Hla Myint Htoon
- Singapore Eye Research Institute, 11 Third Hospital Ave, Singapore City, 168751, Singapore.,Duke-NUS Medical School, 8 College Road, Singapore City, 169857, Singapore
| | - Tibor Lohmann
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany
| | - Andreas Videa
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany
| | - Antonis Koutsonas
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany
| | - Hannah Schellhase
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany
| | - David Kuerten
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany
| | - Peter Walter
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany
| | - Matthias Fuest
- Department of Ophthalmology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany.
| |
Collapse
|
5
|
Jabłońska J, Lewczuk K, Konopińska J, Mariak Z, Rękas M. Microinvasive glaucoma surgery: a review and classification of implant-dependent procedures and techniques. Acta Ophthalmol 2022; 100:e327-e338. [PMID: 33988310 PMCID: PMC9291507 DOI: 10.1111/aos.14906] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 03/08/2021] [Accepted: 04/22/2021] [Indexed: 12/25/2022]
Abstract
The aim of this article is to discuss how physiology and anatomical background affect the effectiveness of implant‐dependent microinvasive glaucoma surgery (MIGS). First, we provide a micro view of aqueous outflow and tissue behaviour. Second, we review studies exploring the mechanisms of the pressure‐lowering effect of MIGS, as well as tissue behaviour during aqueous flow and tissue motion. We also describe and classify microinvasive surgical procedures and the most important types of implants, as well as their mechanisms of action, implantation techniques and efficacy. Further, we summarize the indications and surgical results presented in recent studies, providing an evidence‐based update on novel and emerging MIGS techniques for the treatment of open‐angle glaucoma. These data can help surgeons to personalize the management of glaucoma and to choose the best MIGS option for individual glaucoma patients.
Collapse
Affiliation(s)
- Joanna Jabłońska
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| | - Katarzyna Lewczuk
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| | - Joanna Konopińska
- Department of Ophthalmology Medical University of Bialystok Białystok Poland
| | - Zofia Mariak
- Department of Ophthalmology Medical University of Bialystok Białystok Poland
| | - Marek Rękas
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| |
Collapse
|
6
|
Fujita A, Hashimoto Y, Matsui H, Yasunaga H, Aihara M. Recent trends in glaucoma surgery: a nationwide database study in Japan, 2011-2019. Jpn J Ophthalmol 2022; 66:183-192. [PMID: 35044562 DOI: 10.1007/s10384-021-00898-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 11/24/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE To clarify recent trends in glaucoma surgery in Japan, including minimally invasive glaucoma surgery. STUDY DESIGN Retrospective cohort study. METHODS We used the Diagnostic Procedure Combination database, a nationwide administrative database in Japan. Patients who underwent glaucoma-related procedures were included. We calculated the number of surgeries stratified by procedures and age categories. We also investigated the number of glaucoma-related procedures in combination with cataract surgery. RESULTS From fiscal years 2011 to 2019, we identified 134,331 glaucoma-related procedures at 720 hospitals. The total number of glaucoma-related procedures increased by 215% from 6516 in 2011 to 20,569 in 2019. The numbers of filtering surgeries, trabeculotomies, and glaucoma drainage devices with plates [GDD(p +)] procedures significantly increased (P = 0.002, 0.002, and 0.006, respectively), whereas the number of cyclocryotherapy procedures significantly decreased (P = 0.002). The number of iStent procedures increased by 49% from 371 in 2018 to 551 in 2019. The ≥ 65 year age group accounted for > 80% of the iStent procedures. In the 0 to 14 year age group, trabeculotomy accounted for about 70% of the procedures, and the GDD(p +) procedure became the second most common procedure after trabeculotomy because of the decrease in filtering surgeries. Among combination surgeries, trabeculotomy was most frequently performed. The proportion of combination surgery increased, especially in trabeculotomy. CONCLUSIONS The total number of glaucoma-related procedures increased throughout the observation period. Before 2017 filtering surgery was the most common procedure, whereas trabeculotomy was most common after 2018. The proportion of trabeculotomies performed in combination with cataract surgery continuously increased.
Collapse
Affiliation(s)
- Asahi Fujita
- Department of Ophthalmology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan. .,Department of Clinical Epidemiology and Health Economics, School of Public Health, The University of Tokyo, Tokyo, Japan.
| | - Yohei Hashimoto
- Department of Ophthalmology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.,Department of Clinical Epidemiology and Health Economics, School of Public Health, The University of Tokyo, Tokyo, Japan
| | - Hiroki Matsui
- Department of Clinical Epidemiology and Health Economics, School of Public Health, The University of Tokyo, Tokyo, Japan
| | - Hideo Yasunaga
- Department of Clinical Epidemiology and Health Economics, School of Public Health, The University of Tokyo, Tokyo, Japan
| | - Makoto Aihara
- Department of Ophthalmology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| |
Collapse
|
7
|
Salimi A, Watt H, Harasymowycz P. Long-term outcomes of two first-generation trabecular micro-bypass stents (iStent) with phacoemulsification in primary open-angle glaucoma: eight-year results. EYE AND VISION 2021; 8:43. [PMID: 34782017 PMCID: PMC8594216 DOI: 10.1186/s40662-021-00263-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 10/11/2021] [Indexed: 02/06/2023]
Abstract
Background The short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up. Methods This longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery. Eight-year efficacy outcomes included mean intraocular pressure (IOP) and medications, as well as surgical success. Eight-year safety outcomes included best-corrected visual acuity (BCVA), visual field mean deviation (VF-MD), cup-to-disc ratio (CDR), retinal nerve fiber layer (RNFL) thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, and adverse events. Results A total of 62 eyes with primary open-angle glaucoma (POAG) were included. At 8 years postoperative, IOP reduced by 26% from 19.2 ± 3.9 mmHg preoperatively to 14.2 ± 2.4 mmHg (P < 0.001), 91.1% of eyes achieved IOP ≤ 18 mmHg (vs. 51.6% preoperatively), 69.6% of eyes achieved IOP ≤ 15 mmHg (vs. 14.5% preoperatively), and 25% of eyes achieved IOP ≤ 12 mmHg (vs. 1.6% preoperatively). Medication use decreased by 17.9% from 2.8 ± 1.1 preoperatively to 2.3 ± 1.2 (P = 0.018). Surgical success was 90%, as six eyes underwent subsequent glaucoma surgeries. Safety measures of BCVA, CDR, RNFL thickness and GC-IPL thickness remained stable through 8 years postoperative. VF-MD remained stable until postoperative year 5 and subsequently progressed according to the natural history of glaucomatous disease. Conclusions Implantation of two iStents with concomitant cataract surgery is an effective and safe treatment option for surgery-naïve POAG eyes, evidenced by significant IOP and medication reductions, reasonable surgical success, and favorable safety outcomes, throughout the 8-year follow-up. Our data additionally supports the efficacy of this combined procedure in stabilizing or slowing disease progression. Supplementary Information The online version contains supplementary material available at 10.1186/s40662-021-00263-1.
Collapse
Affiliation(s)
- Ali Salimi
- Department of Ophthalmology, Faculty of Medicine, McGill University, Montreal, QC, Canada.,Montreal Glaucoma Institute, Montreal, QC, Canada
| | - Harrison Watt
- Faculty of Medicine, McGill University, Montreal, QC, Canada
| | - Paul Harasymowycz
- Montreal Glaucoma Institute, Montreal, QC, Canada. .,Department of Ophthalmology, University of Montreal, 4135 de Rouen, Montreal, QC, H1V1G5, Canada.
| |
Collapse
|
8
|
Efficacy of Selective Laser Trabeculoplasty after iStent Implantation in Primary Open-Angle Glaucoma. J Pers Med 2021; 11:jpm11080797. [PMID: 34442441 PMCID: PMC8400945 DOI: 10.3390/jpm11080797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 07/31/2021] [Accepted: 08/13/2021] [Indexed: 11/17/2022] Open
Abstract
iStent implantation is thought to augment the trabecular outflow channel in the anterior segment of the eye. We hypothesized that iStent with subsequent selective laser trabeculoplasty (SLT) would better control the intraocular pressure (IOP) compared to standalone SLT in patients with primary open-angle glaucoma (POAG). We, therefore, determined if the presence of an iStent combined with SLT was statistically associated with IOP lowering compared to standalone SLT. Through retrospective electronic medical record review, records of 824 eyes from 440 patients who received primary SLT without a history of iStent were considered. Additionally, 42 eyes from 28 patients who received SLT after combined phacoemulsification and iStent implantation that failed to control intraocular pressure (IOP) and/or the progression of the disease were retrospectively reviewed. IOP and number of medications, which were tracked in each patient for up to 12 months post laser, were also examined. Successful outcome was defined as a statistically significant reduction in IOP or number of medications at 6 months. As defined in univariate analysis (p ≤ 0.01), multivariate analysis included iStent, age, sex, race, and initial IOP as variables. IOP reduction was statistically associated with patients pre-SLT IOP (p < 0.001) but not with patients with iStent (p = 0.222). Medication reduction was statistically associated with the pre-SLT number of medications (p < 0.001) and iStent (p < 0.001). In eyes that received SLT, iStent was not statistically associated with a greater reduction in IOP compared to controls, but was associated with a higher reduction in the overall number of medications used 6 months after receiving SLT. The work presented should guide clinicians to consider SLT as an effective therapy after iStent implantation, in terms of glaucoma medication reduction in iStent patients, but clinicians should know that the presence of an iStent does not necessarily make subsequent SLT more effective at lowering IOP.
Collapse
|
9
|
Abstract
Micro- or minimally invasive glaucoma surgeries (MIGS) have been the latest addition to the glaucoma surgical treatment paradigm. This term refers not to a single surgery, but rather to a group of distinct procedures and devices that aim to decrease intraocular pressure. Broadly, MIGS can be categorized into surgeries that increase the trabecular outflow [Trabectome, iStent (first and second generations), Hydrus microstent, Kahook Dual Blade and gonioscopy-assisted transluminal trabeculotomy], surgeries that increase suprachoroidal outflow (Cypass microstent and iStent Supra), and conjunctival bleb-forming procedures (Xen gel stent and InnFocus microshunt). Compared to traditional glaucoma surgeries, such as trabeculectomy and glaucoma drainage device implantation (Ahmed, Baerveldt, and Molteno valves), MIGS are touted to have less severe complications and shorter surgical time. MIGS represent an evolving field, and the efficacy and complications of each procedure should be considered independently, giving more importance to high-quality and longer-term studies.
Collapse
Affiliation(s)
- David J Mathew
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario M5T 2S8, Canada;
| | - Yvonne M Buys
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario M5T 2S8, Canada;
| |
Collapse
|
10
|
Hamze H, Mohite AA, Pandey P, Sung VCT, Masood I. Comparison of 1-year surgical outcomes of combined cataract surgery and gonioscopy-assisted transluminal trabeculotomy (GATT) versus cataract surgery and iStent Inject. Graefes Arch Clin Exp Ophthalmol 2021; 259:3035-3044. [PMID: 34014384 DOI: 10.1007/s00417-021-05133-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 02/11/2021] [Accepted: 02/16/2021] [Indexed: 10/21/2022] Open
Abstract
PURPOSE Evaluate the efficacy, safety, and complication rates of phacoemulsification cataract surgery when combined with either gonioscopy-assisted transluminal trabeculotomy (GATT) or iStent Inject. METHODS This is a retrospective case-control study to compare the surgical outcomes of combined phacoemulsification cataract surgery with either GATT (phaco-GATT) or iStent Inject (phaco-iStent). Both groups had at least 1-year follow-up. The primary outcome measures were IOP and number of glaucoma medications (NGMs) at 1 year. Secondary outcomes measures were best corrected visual acuity (BCVA) and intra- or postoperative complications within the first year of follow-up. Success was defined as intraocular pressure (IOP) < 21 mmHg and ≥ 20% reduction in IOP at 1 year regardless of the NGM. RESULTS Each group included 37 patients. The median baseline IOP (24 vs 17) and NGM (3 vs 2) were higher in the phaco-GATT group (p < 0.001). Phaco-GATT achieved a 38% (p < 0.0001) reduction in IOP compared to 13.2% (p < 0.001) in the phaco-iStent group at 1-year follow-up. The reduction in IOP and NGM was significantly higher in the phaco-GATT group (p < 0.01). After adjusting for baseline IOP, the reduction in IOP at 12 months was still significantly higher in the phaco-GATT group (p = 0.042). At 1 year, 86.4% of patients in the phaco-GATT group met the success criteria compared to 35.1% in the phaco-iStent group. Safety outcomes were slightly favourable in the phaco-iStent group. CONCLUSION Phaco-GATT and phaco-iStent showed a significant reduction in IOP and NGM, with phaco-GATT having a significantly higher reduction. Phaco-iStent appears to have a higher safety profile and is probably preferable in monocular patients and those with a high risk of bleeding.
Collapse
Affiliation(s)
- Hisham Hamze
- Birmingham and Midland Eye Centre, City Hospital, Sandwell and West Birmingham Hospitals NHS Trust, Dudley Road, Birmingham, B18 7QH, UK
| | - Abhijit Anand Mohite
- New Cross Hospital, Royal Wolverhampton NHS Trust, Wolverhampton Rd, Heath Town, Wolverhampton, WV10 0QP, UK
| | - Pravin Pandey
- Birmingham and Midland Eye Centre, City Hospital, Sandwell and West Birmingham Hospitals NHS Trust, Dudley Road, Birmingham, B18 7QH, UK
| | - Velota C T Sung
- Birmingham and Midland Eye Centre, City Hospital, Sandwell and West Birmingham Hospitals NHS Trust, Dudley Road, Birmingham, B18 7QH, UK
| | - Imran Masood
- Birmingham and Midland Eye Centre, City Hospital, Sandwell and West Birmingham Hospitals NHS Trust, Dudley Road, Birmingham, B18 7QH, UK.
| |
Collapse
|
11
|
Standalone iStent Trabecular Micro-bypass Glaucoma Surgery: A Systematic Review and Meta-Analysis. J Glaucoma 2021; 30:606-620. [PMID: 33596009 DOI: 10.1097/ijg.0000000000001805] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 01/07/2021] [Indexed: 11/25/2022]
Abstract
PRECIS Standalone trabecular micro-bypass glaucoma surgery with the iStent devices is associated with clinically relevant reductions in intraocular pressure (IOP) sustained over a reasonably long-term while simultaneously reducing medication burden and a relatively favorable safety profile. PURPOSE While there is a relatively large body of evidence supporting the implantation of the iStent trabecular micro-bypass devices during phacoemulsification in patients with open-angle glaucoma (OAG), its efficacy as a standalone procedure has been less widely reported. The aims of this study were to systematically identify and quantitatively evaluate the efficacy of iStent devices (iStent and iStent inject) when performed independently of cataract surgery in patients with OAG. METHODS A systematic review of the literature was undertaken in August 2019 to identify studies of standalone trabecular micro-bypass glaucoma surgery with iStent devices in patients with OAG. All randomized trials were considered and nonrandomized studies that included at least 6 months of follow-up or more than 10 eyes. Key efficacy analyses included postoperative IOP and medication use, which were used to evaluate weighted mean differences from baseline, and the proportion of eyes free of ocular medication. Postoperative adverse events were descriptively summarized. RESULTS A total of 13 studies were identified including 4 randomized controlled trials and 9 nonrandomized or single-arm studies providing data for 778 eyes. In eyes implanted with iStent devices, a weighted mean IOP reduction of 31.1% was observed at 6 to 12 months. In studies reporting longer-term outcomes (36 to 48 mo or 60 mo), the weighted mean IOP reduction was 30.4% and 32.9%, respectively. The pooled weighted mean reduction in IOP from baseline across all studies at 6 to 12 months and 36 to 60 months poststent implantation was 7.01 mm Hg (95% confidence interval: 5.91, 8.11) and 6.59 mm Hg (95% confidence interval: 5.55, 7.63), respectively. Medication burden was reduced by ~1.0 medication at 6 to 18 months and 1.2 medications at 36 to 60 months. Adverse events reported in more than 5% of participants were progression of pre-existing cataract/cataract surgery and loss of best-corrected visual acuity but these rates were no different to those reported in comparator medical therapy study arms. CONCLUSIONS The results from these studies support the independent effect of the iStent trabecular bypass devices on IOP and medication burden over a duration of follow-up of up to 5 years.
Collapse
|
12
|
Kasahara M, Shoji N. Effectiveness and limitations of minimally invasive glaucoma surgery targeting Schlemm's canal. Jpn J Ophthalmol 2020; 65:6-22. [PMID: 33150512 DOI: 10.1007/s10384-020-00781-w] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Accepted: 09/07/2020] [Indexed: 12/15/2022]
Abstract
Glaucoma surgery is performed to lower intraocular pressure (IOP); ideally, the IOP reduction is safely maintained for an extended period of time. Although trabeculectomy was considered the gold standard for glaucoma surgery for many years because of its effective IOP reduction, yet now it is considered unsafe because of serious complications. In recent years, minimally invasive glaucoma surgery (MIGS), which emphasizes safety and can be performed rapidly, has become widespread. Because MIGS does not involve conjunctival incisions, patients can undergo future trabeculectomy. If IOP reduction can be maintained safely, the number of anti-glaucoma drops can be reduced and visual function maintained, good outcomes for patients with glaucoma. Currently, many types of MIGS approved in Japan are reported to yield relatively good results, with targets of approximately 15-19 mmHg. However, the IOP-lowering effects of MIGS are limited. In procedures targeting Schlemm's canal, it is difficult to lower IOP beyond episcleral venous pressure. In some instances, a beneficial effect cannot be achieved if function is reduced beyond the collector channel. There are many unclear aspects regarding long-term outcomes following MIGS. Notably, investigation is ongoing to determine which patients are likely to benefit most from surgery. Based on previous reports, this review describes the characteristics and results of MIGS, approved in Japan, as well as underlying factors that affect the preoperative predictions and outcomes of the surgical procedure.
Collapse
Affiliation(s)
- Masayuki Kasahara
- Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan
| | - Nobuyuki Shoji
- Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan.
| |
Collapse
|
13
|
The Effectiveness of First-Generation iStent Microbypass Implantation Depends on Initial Intraocular Pressure: 24-Month Follow-Up-Prospective Clinical Trial. J Ophthalmol 2020; 2020:8164703. [PMID: 32676205 PMCID: PMC7330650 DOI: 10.1155/2020/8164703] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 05/04/2020] [Accepted: 05/27/2020] [Indexed: 11/18/2022] Open
Abstract
Background Evaluation of efficacy of the iStent trabecular bypass implant in reducing intraocular pressure (IOP) depending on the value pretreatment IOP and number of medications used before surgery in patients with primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma (PXG) and coexisting cataract. Methods A prospective, uncontrolled, interventional case series. 72 patients, on a mean age of 72.42 ± 9.17, were divided into two groups depending on baseline IOP: group I < 26 mmHg and group II ≥ 26 mmHg. All subjects underwent ab interno implantation of a single iStent together with cataract surgery. Best-corrected visual acuity (BCVA), IOP, number of antiglaucoma medications, visual field, and number and type of complications were examined before and after surgery. Postoperative patients were followed up at 1, 7, and 30 days and 3, 6, 12, and 24 months. All the patients were washed out preoperatively as well as postoperatively. Results The mean observation time was 20 months. The mean preoperative IOP was 21.03 ± 1.44 mmHg in group I and reduced to mean 15.60 ± 2.12 mmHg after operation. In group II, mean IOP reduced from 26.00 ± 0.00 to 18.56 ± 1.81 (p=0.003). Mean glaucoma medications decreased from 1.35 ± 0.65 to 0.29 ± 0.52 in group I (p < 0.001) and from 2.89 ± 1.18 to 1.33 ± 1.50 in group II (p < 0.001). At 24 months, medication reduction was significantly greater in group I than group II (p=0.026). Conclusions Combined cataract surgery with implantation of iStent seems to be an effective procedure in patients with mild-to-moderate open-angle glaucoma and cataract. In patients with baseline IOP < 26 mmHg, surgery reduced IOP and medication use significantly declined to 2 years, with greater reductions achieved versus patients with baseline IOP ≥ 26 mmHg. This trial is registered with NCT03807869.
Collapse
|
14
|
Use of iStent as a Standalone Operation in Patients with Open-Angle Glaucoma. J Ophthalmol 2020; 2020:8754730. [PMID: 32566270 PMCID: PMC7267876 DOI: 10.1155/2020/8754730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 05/03/2020] [Accepted: 05/12/2020] [Indexed: 12/04/2022] Open
Abstract
Purpose The iStent provides a direct pathway for aqueous outflow from the anterior chamber to Schlemm's canal in patients with open-angle glaucoma (OAG). We performed a meta-analysis to evaluate the effectiveness of iStent as a standalone operation in patients with OAG in reducing the intraocular pressure (IOP) and the number of topical glaucoma medications. Methods We searched various databases between January 1, 2000, and September 30, 2019, and included only peer-reviewed, prospective, or retrospective clinical studies in our analyses. Details regarding the IOP and the number of medications at baseline and end point were recorded from each study. Standardized mean differences (SMDs) of IOP and medication numbers were calculated. Furthermore, the success rate (the proportion of IOP ≤18 mmHg and IOP reduction ≥20% at end point) and the complication rate were also summarized. Finally, a subgroup analysis was done based on the iStent generation (first and second), follow-up duration (≤6, 6–18, 18–36, and >36 months), and iStent number (one, two, and three). The outcome measures were aggregated SMDs computed from each study. Results A total of 17 studies with 978 eyes were included in this analysis. All studies demonstrated a reduction in IOP after iStent implantation. Aggregated SMDs of IOP revealed a significant reduction (SMD = −2.64, 95% confidence interval (CI): −3.21 to −2.07). The success rate was significantly good, and most of the complication rates were low. The number of medications was also significantly reduced (SMD = −1.71, 95% CI: −2.18 to −1.24). The subgroup analysis revealed a reduction in IOP and medication burden in each category of iStent generation, follow-up duration of up to 42 months, and iStent numbers. Conclusion Use of iStent as a standalone procedure does reduce the IOP and the number of glaucoma medications. The benefit of iStent lasts for at least 42 months.
Collapse
|
15
|
Comparison of Using One Trabecular Microbypass Stent versus Two during Cataract Surgery at Two Sites: One-Year Follow-Up. BIOMED RESEARCH INTERNATIONAL 2020; 2020:1920352. [PMID: 32337227 PMCID: PMC7166285 DOI: 10.1155/2020/1920352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Revised: 01/29/2020] [Accepted: 03/07/2020] [Indexed: 11/17/2022]
Abstract
Purpose To compare IOP and ocular hypotensive medication reduction of using one trabecular microbypass stent versus two in patients with open-angle glaucoma. Setting. Palo Alto Veterans Affairs (VA) Hospital and the Byers Eye Institute at Stanford University, Palo Alto, California, USA. Design Retrospective case series. Methods A chart review included patients who underwent trabecular microbypass implantation with cataract surgery in 2015-2017, with at least one-year follow-up. Subjects were divided into two groups by location (always one stent at Stanford versus two stents at the VA). Primary outcome measures included IOP and medication reduction at baseline and 12-month follow-up. Results 132 subjects (166 eyes) were included. The preoperative IOP was 16.3 ± 3.4 mmHg on 2.6 ± 1.1 medications in the one-stent group (N = 85) and 17.5 ± 3.1 mmHg on 2.7 ± 0.6 medications in the two-stent group (N = 81). There was no significant difference between the two groups (p = 0.06). At the 12-month visit, there was a 13.37% ± 2.93 reduction in IOP in the 1-stent group (p ≤ 0.001) and 13.49% ± 2.69 in the 2-stent group (p ≤ 0.001); both were not significantly different from each other (p = 0.074). At 12 months, there was also a 14.5% reduction in medication use for the 1-stent group and 15.3% reduction in the 2-stent group, both statistically significant from baseline, (p = 0.022 and p = 0.037, respectively). Conclusions Implantation with either one or two stents during cataract surgery in patients with glaucoma demonstrated similar IOP and med reduction in both groups between the two sites.
Collapse
|
16
|
Chen DZ, Sng CCA, Sangtam T, Thomas A, Shen L, Huang PK, Cheng J. Phacoemulsification vs phacoemulsification with micro‐bypass stent implantation in primary angle closure and primary angle closure glaucoma: A randomized single‐masked clinical study. Clin Exp Ophthalmol 2020; 48:450-461. [DOI: 10.1111/ceo.13721] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Revised: 12/15/2019] [Accepted: 12/30/2019] [Indexed: 12/11/2022]
Affiliation(s)
- David Z. Chen
- Department of OphthalmologyNational University Hospital Singapore Singapore
| | - Chelvin C. A. Sng
- Department of OphthalmologyNational University Hospital Singapore Singapore
- Glaucoma ServiceMoorfields Eye Hospital London UK
- Singapore Eye Research Institute Singapore Singapore
| | - Tiakumzuk Sangtam
- Department of Ophthalmology and Visual ScienceKhoo Teck Puat Hospital Singapore Singapore
| | - Anoop Thomas
- Department of Ophthalmology and Visual ScienceKhoo Teck Puat Hospital Singapore Singapore
| | - Liang Shen
- Biostatistics Unit, Yong Loo Lin School of MedicineNational University of Singapore Singapore Singapore
| | - Philemon K. Huang
- Department of Ophthalmology and Visual ScienceKhoo Teck Puat Hospital Singapore Singapore
| | - Jason Cheng
- Department of Ophthalmology and Visual ScienceKhoo Teck Puat Hospital Singapore Singapore
- Department of OphthalmologyUniversity of New South Wales, Liverpool Hospital Sydney Australia
| |
Collapse
|
17
|
Rosdahl JA, Gupta D. Prospective Studies of Minimally Invasive Glaucoma Surgeries: Systematic Review and Quality Assessment. Clin Ophthalmol 2020; 14:231-243. [PMID: 32158182 PMCID: PMC6986542 DOI: 10.2147/opth.s239772] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Accepted: 12/24/2019] [Indexed: 12/05/2022] Open
Abstract
Glaucoma is a common blinding disease; while there is no cure, effective treatments include medications, laser, and incisional surgery. There is significant interest from patients and doctors to develop safer surgical options throughout the spectrum of disease, to minimize treatment burden in mild glaucoma patients and to minimize risk of complications in patients needing more aggressive treatment. Surgical procedures called Minimally or Micro-Invasive Glaucoma Surgery (MIGS) are growing in popularity. Eighty-seven prospective studies on MIGS were identified and assessed for quality. Most (74%) did not have a control group. Twelve of the highest quality were reviewed. MIGS procedures appeared to have fewer complications, and lowered intraocular pressure, and reduced medication use. Studies were limited by small sample size, narrow spectrum of glaucomatous disease, and/or conflicts of interest. There is a need for high quality, independently funded and performed, comparative studies on the MIGS to help make treatment decisions.
Collapse
Affiliation(s)
- Jullia A Rosdahl
- Department of Ophthalmology, Duke University, Durham, NC27710, USA
| | - Divakar Gupta
- Department of Ophthalmology, Duke University, Durham, NC27710, USA
| |
Collapse
|
18
|
Wang SY, Singh K, Stein JD, Chang RT. Ocular Antihypertensive Medication Use After iStent Implantation Concurrent With Cataract Surgery vs Cataract Surgery Alone in a Large US Health Care Claims Database. JAMA Ophthalmol 2019; 137:21-27. [PMID: 30267072 DOI: 10.1001/jamaophthalmol.2018.4461] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance The iStent Trabecular Micro-Bypass (Glaukos Corporation) is a minimally invasive glaucoma implant used in conjunction with cataract surgery to lower intraocular pressure. Objective To determine whether implantation of the iStent concurrent with cataract surgery is associated with reduced use of ocular antihypertensive medications in a US health care claims database. Design, Setting, and Participants Retrospective, observational longitudinal cohort study of individuals enrolled in a US managed care network who underwent iStent implantation with cataract surgery (iStent/CEIOL) from 2012 to 2016 (n = 1509 bilateral and n = 1462 unilateral surgery). A control group of individuals who underwent bilateral cataract surgery only (CEIOL) were matched 1:1 to patients undergoing bilateral iStent/CEIOL on baseline demographic and clinical factors. Data were analyzed between November 1, 2017, and January 31, 2018. Main Outcomes and Measures The number of topical ocular antihypertensive agents used postoperatively by patients undergoing iStent/CEIOL compared with baseline and with matched CEIOL control individuals, and hazard ratios with 95% confidence intervals for sustained reduced use of at least 1 topical ocular antihypertensive agent postoperatively. Results Of the 2971 eligible enrollees, mean age at first surgery was 74.3 years, and 1659 (55.8%) were women. Patients undergoing iStent/CEIOL had diagnoses that included primary open-angle glaucoma (n = 2329; 78.4%), narrow angles (n = 381; 12.8%), and secondary glaucomas (n = 261; 8.8%). At baseline, 1223 (41.2%) were receiving no topical glaucoma agents; 876 (29.5%), 437 (14.7%), and 435 (14.6%) were receiving 1, 2, or at least 3 agents, respectively. Although only 678 persons (22.8%) completed at least 2 years of postoperative follow-up, the proportion of patients receiving no drops increased postoperatively (64.7%, 20-24 months, P < .001, χ2). Patients receiving at least 1 topical agent at baseline had mean reduction of 1.01 and 0.61 medications used at 20 to 24 months with bilateral or unilateral surgery, respectively (both P < .001, paired t). Sustained reduction in glaucoma medication use was more likely in patients receiving at least 3 vs 1 medication at baseline (hazard ratio, 1.68; 95% CI, 1.36-2.09). Compared with matched control individuals undergoing CEIOL, patients undergoing bilateral iStent/CEIOL had a greater mean reduction in drops used (0.99 vs 0.49; postoperative month 20-24; P < .001; paired t) and a higher proportion receiving no drops postoperatively (73.5% vs 55.3%, postoperative month 20-24; P < .001; χ2). Conclusions and Relevance Implantation of the iStent trabecular micro-bypass stent concurrent with cataract surgery was associated with moderately reduced use of topical ocular antihypertensive medication. Reduction in the use of glaucoma medications may lessen the burden of medication adverse effects and promote better adherence.
Collapse
Affiliation(s)
- Sophia Y Wang
- Byers Eye Institute, Stanford University, Palo Alto, California
| | - Kuldev Singh
- Byers Eye Institute, Stanford University, Palo Alto, California
| | - Joshua D Stein
- Department of Ophthalmology and Visual Sciences, Center for Eye Policy and Innovation, University of Michigan, Ann Arbor.,Department of Health Management and Policy, University of Michigan, Ann Arbor
| | - Robert T Chang
- Byers Eye Institute, Stanford University, Palo Alto, California
| |
Collapse
|
19
|
Ferguson TJ, Ibach M, Schweitzer J, Karpuk KL, Stephens JD, Berdahl JP. Trabecular micro‐bypass stent implantation with cataract extraction in pigmentary glaucoma. Clin Exp Ophthalmol 2019; 48:37-43. [DOI: 10.1111/ceo.13638] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 07/29/2019] [Accepted: 09/07/2019] [Indexed: 11/30/2022]
Affiliation(s)
| | - Mitch Ibach
- Vance Thompson Vision Sioux Falls South Dakota
| | | | | | | | | |
Collapse
|
20
|
Salimi A, Winter A, Li C, Harasymowycz P, Saheb H. Effect of Topical Corticosteroids on Early Postoperative Intraocular Pressure Following Combined Cataract and Trabecular Microbypass Surgery. J Ocul Pharmacol Ther 2019; 35:413-420. [DOI: 10.1089/jop.2019.0019] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Ali Salimi
- Faculty of Medicine, McGill University, Montreal, Quebec, Canada
| | - Aaron Winter
- Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Cody Li
- Department of Ophthalmology, McGill University, Montreal, Quebec, Canada
| | - Paul Harasymowycz
- Department of Ophthalmology, University of Montreal, Montreal, Quebec, Canada
- Montreal Glaucoma Institute, Montreal, Quebec, Canada
| | - Hady Saheb
- Department of Ophthalmology, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
21
|
Hooshmand J, Rothschild P, Allen P, Kerr NM, Vote BJ, Toh T. Minimally invasive glaucoma surgery: Comparison of iStent with iStent
inject
in primary open angle glaucoma. Clin Exp Ophthalmol 2019; 47:898-903. [DOI: 10.1111/ceo.13526] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 03/13/2019] [Accepted: 04/23/2019] [Indexed: 11/28/2022]
Affiliation(s)
| | - Philip Rothschild
- Tasmanian Eye Institute Launceston Tasmania Australia
- Clinical SchoolUniversity of Tasmania Launceston Tasmania Australia
| | - Penny Allen
- Tasmanian Eye Institute Launceston Tasmania Australia
- Clinical SchoolUniversity of Tasmania Launceston Tasmania Australia
| | - Nathan M. Kerr
- Royal Victorian Eye and Ear Hospital Melbourne Victoria Australia
| | | | - Tze'Yo Toh
- Tasmanian Eye Institute Launceston Tasmania Australia
| |
Collapse
|
22
|
Lee GA, Porter AJ, Vincent RA, Makk J, Vincent SJ. Combined phacoemulsification and microinvasive glaucoma surgery in comparison to phacoemulsification alone for open angle glaucoma. Eye (Lond) 2019; 34:312-318. [PMID: 31076657 DOI: 10.1038/s41433-019-0459-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Revised: 03/19/2019] [Accepted: 04/22/2019] [Indexed: 11/10/2022] Open
Abstract
IMPORTANCE Microinvasive glaucoma surgery (MIGS) combined with phacoemulsification is increasingly utilised in glaucoma management. OBJECTIVE To describe the postoperative outcomes of phacoemulsification alone compared to combined phacoemulsification and iStent (Glaukos, San Clemente, CA) or Hydrus (Ivantis, Irvine, CA) for open angle glaucoma. METHODS Retrospective single surgeon comparative case series in a private practice setting. A total of 297 eyes in 190 patients (M:F = 85:105) were included consecutively from March 2011 to June 2017 with the data analysed using linear mixed models. Main outcome measures were intraocular pressure (IOP) and number of medications. RESULTS By 6 months, all groups showed a reduction in IOP, with the combined iStent group by 4.2 mm Hg and the combined Hydrus group by 4.5 mm Hg, and this trend was sustained with follow-up to two years. All groups also showed a reduction in number of medications, with the phacoemulsification alone cases by 0.3, the combined iStent group by 0.7 and the combined Hydrus group by 1.1 medications. Both the combined surgeries had sustained reduction of number of medications with follow-up to 2 years. Postoperative complications from MIGS device insertion were uncommon and all resolved by one month. CONCLUSIONS AND RELEVANCE The combination of phacoemulsification and a MIGS device in open angle glaucoma patients reduced the intraocular pressure and the number of medications by the first postoperative month and had longer-term effects at 2 years follow-up. If the device is inserted without intraoperative complication, the rate of significant short-term risks are low.
Collapse
Affiliation(s)
- Graham A Lee
- City Eye Centre, Brisbane, QLD, Australia. .,University of Queensland, Brisbane, QLD, Australia. .,Mater Health Services, Brisbane, QLD, Australia.
| | | | | | | | | |
Collapse
|
23
|
Hernstadt DJ, Cheng J, Htoon HM, Sangtam T, Thomas A, Sng CCA. Case Series of Combined iStent Implantation and Phacoemulsification in Eyes with Primary Angle Closure Disease: One-Year Outcomes. Adv Ther 2019; 36:976-986. [PMID: 30820873 DOI: 10.1007/s12325-019-00899-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of combined iStent® trabecular micro-bypass device (Glaukos, Laguna Hills, CA) and phacoemulsification in eyes with primary angle closure disease. METHODS A two-center prospective interventional case series of consecutive patients with primary angle closure (PAC) or primary angle closure glaucoma (PACG) on at least one glaucoma medication, who underwent iStent implantation with cataract surgery. Postoperatively, patients were assessed on days 1 and 7, and months 1, 3, 6, and 12. The intraocular pressure (IOP), glaucoma medication use, visual acuity, and the presence of complications were assessed at each visit. Complete success was defined as IOP reduction of at least 20% without the use of glaucoma medications. RESULTS Thirty-seven eyes with angle closure disease were included in this study. At 1-year, postoperative mean IOP (14.8 ± 3.94 mmHg) was significantly decreased compared with preoperative medicated (17.5 ± 3.82 mmHg, p = 0.008) and unmedicated (24.6 ± 3.41 mmHg, p < 0.001) IOP. Complete success was achieved in 89.2% of the eyes. The number of glaucoma medications decreased from 1.49 ± 0.77 to 0.14 ± 0.48 (p < 0.001). Preoperative medicated IOP was a risk factor for failure (hazard ratio 3.45, 95% confidence interval 1.52-7.85, p = 0.003), after adjustment for age, gender, and race. The most common postoperative complications were iStent occlusion with iris (27.0%) and hyphema (18.9%). There were no sight-threatening intraoperative or postoperative complications. CONCLUSION Combined iStent implantation with cataract surgery was effective in lowering the IOP and the number of glaucoma medications for at least 12 months, with a favorable safety profile. FUNDING Glaukos Corporation; NMRC Science Translational and Applied Research (STAR) award.
Collapse
Affiliation(s)
| | - Jason Cheng
- Department of Ophthalmology, Khoo Teck Puat Hospital, Singapore, Singapore
- Vision Eye Institute, Sydney, Australia
- Department of Ophthalmology, Liverpool Hospital, Sydney, Australia
| | | | - Tiakumzuk Sangtam
- Department of Ophthalmology, Khoo Teck Puat Hospital, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore
| | - Anoop Thomas
- Department of Ophthalmology, Khoo Teck Puat Hospital, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore
| | - Chelvin Cheryl Agnes Sng
- Department of Ophthalmology, National University Hospital, Singapore, Singapore.
- Singapore Eye Research Institute, Singapore, Singapore.
- Moorfields Eye Hospital, London, UK.
| |
Collapse
|
24
|
Kim WJ, Kim JM, Lee WH, Kim KN, Kim CS. Effect of combined goniotomy and phacoemulsification on intraocular pressure in open-angle glaucoma patients. Clin Exp Ophthalmol 2019; 47:757-765. [PMID: 30924282 DOI: 10.1111/ceo.13506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 03/17/2019] [Accepted: 03/24/2019] [Indexed: 11/27/2022]
Abstract
IMPORTANCE Although goniotomy is known to be successful in treating congenital glaucoma, its effect in adult glaucoma patients remains unclear. BACKGROUND To evaluate the efficacy and safety of goniotomy performed simultaneously with cataract surgery in treatment of open-angle glaucoma (OAG). DESIGN Retrospective comparative study. PARTICIPANTS A total of 76 patients with moderately controlled OAG (intraocular pressure [IOP] ≤ 21 mmHg using medications) undergoing cataract surgery. METHODS Comparison of patients who underwent the conventional goniotomy during cataract surgery (combined goniotomy group) with those who underwent cataract surgery alone (phaco group). MAIN OUTCOME MEASURES Changes in IOP and medications, and complications through 12 months. RESULTS Baseline IOP was 18.2 ± 2.4 mmHg in the combined goniotomy group and 17.4 ± 1.9 mmHg in the phaco group; number of medications was 2.6 ± 1.1 and 2.4 ± 0.9, respectively (P > 0.05). The reduction in IOP and medication use from baseline in the combined goniotomy group was significantly greater at 12 months compared to the phaco group (-3.1 ± 2.9 mmHg vs -1.3 ± 2.4 mmHg and -1.2 ± 0.9 vs -0.7 ± 0.9, respectively, both P < 0.05). The success rate was 76.7% in the combined goniotomy group and 50.0% in the phaco group at 12 months (P = 0.021). No significant complication was observed in either group. CONCLUSIONS AND RELEVANCE Combined goniotomy and cataract surgery showed a significantly greater reduction in IOP and number of medications compared to cataract surgery alone at 1 year after surgery, with similarly favourable safety profiles.
Collapse
Affiliation(s)
- Woo-Jin Kim
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea
| | - Ju-Mi Kim
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea
| | - Woo-Hyuk Lee
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea
| | - Kyoung Nam Kim
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea.,Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Korea
| | - Chang-Sik Kim
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea.,Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Korea
| |
Collapse
|
25
|
Ordóñez JE, Ordóñez A, Osorio UM. Cost-effectiveness analysis of iStent trabecular micro-bypass stent for patients with open-angle glaucoma in Colombia. Curr Med Res Opin 2019; 35:329-340. [PMID: 30049226 DOI: 10.1080/03007995.2018.1506022] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
OBJECTIVE To estimate the cost-effectiveness of trabecular micro bypass stent vs laser trabeculoplasty or medications only, for patients with open-angle glaucoma in a setting of the Colombian System Health. METHODS This is a cost-effectiveness analysis that based its assumptions in external data sources, used to extrapolate the quality-of-life related to health, survival, and costs. A Markov model, with stages from 0 (ocular hypertension without glaucoma) to 5 and bilateral blindness, was developed inclusive of Colombians older than 40 years in 2018, from a societal perspective, comparing trabecular micro-bypass stents vs laser trabeculoplasty, timolol + dorzolamide + brimonidine, timolol + dorzolamide + latanoprost, or timolol + dorzolamide + brimatoprost, in terms of clinical and economic outcomes over a lifetime horizon. Both costs and health outcomes had an annual rate discount of 5%. Health outcomes were evaluated in terms of QALYs related with loss of visual acuity. Trabecular micro-bypass costs include the joint use of timolol, and the costs of laser trabeculoplasty include the combined use of timolol + dorzolamide. RESULTS Trabecular micro-bypass stents were estimated to have 127,971 more discounted QALYs vs laser trabeculoplasty; 405,982 vs timolol + dorzolamide + brimonidine; and 378,287 vs timolol + dorzolamide + latanoprost or timolol + dorzolamide + brimatoprost. Cumulative costs with trabecular micro-bypass stents at 40 years was $13,252,318 lower than laser trabeculoplasty; $6,403,534, lower than timolol + dorzolamide + brimonidine; $22,311,064, lower than timolol + dorzolamide + latanoprost; and $29,156,113 lower than timolol + dorzolamide + brimatoprost. CONCLUSIONS The trabecular micro-bypass stent is a highly cost-saving strategy due to more QALYs related to a lower rate of the population with loss of visual acuity in the long-term, and because the costs associated with additional medications and complications are lower with trabecular micro-bypass stents.
Collapse
|
26
|
Mahdavi Fard A, Patel SP, Pourafkari L, Nader ND. Comparing iStent versus CyPass with or without phacoemulsification in patients with glaucoma: a meta-analysis. Ther Adv Chronic Dis 2019; 10:2040622318820850. [PMID: 30728930 PMCID: PMC6357298 DOI: 10.1177/2040622318820850] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Accepted: 09/24/2018] [Indexed: 11/15/2022] Open
Abstract
Bacground The aim of this study was to conduct a meta-analysis to compare the overall intraocular pressure (IOP)-lowering effect of iStent or CyPass as isolated procedures or in combination with cataract extraction. Materials and methods Cochrane review manager 5.3 software (RevMan® 5.3) was used for a meta-analysis of IOPs and the number of antiglaucoma medications in six groups according to the type and number of stents and whether the procedure was isolated or in combination with cataract extraction. Main results A total of 33 out of 446 publications retrieved have been enrolled. The mean changes in IOP in the groups with one iStent and more than two iStents with concurrent cataract extraction were -3.78 ± 0.53 mmHg and -3.89 ± 0.73 mmHg, respectively. The mean differences in IOP in the groups with one iStent and more than two iStents without concurrent cataract extraction were -3.96 ± 0.25 mmHg and -7.48 ± 0.55 mmHg, respectively. The mean changes in IOP in the groups with CyPass implantation with and without concurrent cataract extraction were -4.97 ± 1.38 mmHg and -8.96 ± 0.16 mmHg, respectively. Conclusions Both iStent and CyPass either in combination with cataract extraction or as isolated procedures effectively decrease IOP. This effect is greatest with isolated implantation of CyPass followed by multiple iStents and then single iStent implantation and lasts up to 2 years.
Collapse
Affiliation(s)
- Ali Mahdavi Fard
- Department of Ophthalmology, University at Buffalo, Buffalo, NY, USA Tabriz University of Medical Sciences, Tabriz, Iran
| | - Sangita P Patel
- Department of Ophthalmology, Ross Eye Institute, The State University of New York at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Buffalo, NY, USA Ophthalmology and Research Service, Veterans Administration Western New York Healthcare, System, Buffalo, NY, USA SUNY Eye Institute, Buffalo, NY, USA
| | | | - Nader D Nader
- Department of Anesthesiology, University at Buffalo, 77 Goodell Street, Suite #550, Buffalo, NY 14203, USA
| |
Collapse
|
27
|
A Schlemm Canal Microstent for Intraocular Pressure Reduction in Primary Open-Angle Glaucoma and Cataract. Ophthalmology 2019; 126:29-37. [DOI: 10.1016/j.ophtha.2018.05.012] [Citation(s) in RCA: 113] [Impact Index Per Article: 22.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Revised: 05/01/2018] [Accepted: 05/09/2018] [Indexed: 11/22/2022] Open
|
28
|
Shah S, Rana M, Pandey P, Masood I. Endoscopic Goniosynechialysis for Acute Angle Closure Glaucoma Following Descemet\'s Stripping Automated Endothelial Keratoplasty. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
29
|
Elbably A, Othman TM, Mousa A, Elridy M, Badawy W, Elbably M. Deep Sclerectomy with Porous Collagen in Open-angle Glaucoma, Short-term Study. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
30
|
Popovic M, Campos-Moller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018; 12:67-84. [PMID: 30473602 PMCID: PMC6236117 DOI: 10.5005/jp-journals-10008-1248] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 07/27/2018] [Indexed: 11/23/2022] Open
Abstract
Aim This meta-analysis explores the efficacy and adverse event profile of the iStent, an ab interno implant for the treatment of open-angle glaucoma. Methods A systematic literature search of Ovid MEDLINE and EMBASE was used to identify peer-reviewed original studies that provided efficacy data on the first or second generation iStent for at least five eyes. Intraocular pressure (IOP) was the primary efficacy endpoint, while the number of medication classes was the secondary outcome. Weighted mean differences were reported for continuous endpoints, while a relative risk was computed for dichotomous variables. Review Results The search revealed 545 results, of which 1767 eyes from 28 studies were included. The cohort age was 71.4 ± 5.4 years, and 44.9% of patients were male. There was a significantly greater IOP reduction after the use of two first-generation stents compared to one, irrespective of phacoemulsification status (p < 0.001). Additionally, there was a significantly greater IOP reduction following iStent alone relative to phaco-iStent for the first-generation iStent (p < 0.001) and the iStent inject (p < 0.001). For the first generation stent, combined phaco-iStent provided a greater level of IOP reduction (p < 0.001) and reduction in the number of medication classes relative to phacoemulsification alone (p < 0.001). In total, 22.5% of eyes that received iStent implantation sustained some type of adverse event. The most common adverse events were intraocular pressure elevation, stent blockage or obstruction, stent malposition and hyphema. Conclusion and Clinical Significance Statistically significant differences in efficacy outcomes exist between different numbers of stents and the presence or absence of concurrent phacoemulsification. How to cite this article: Popovic M, Campos-Moller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018;12(2):67-84.
Collapse
Affiliation(s)
- Marko Popovic
- Research Assistant, Faculty of Medicine, University of Toronto, Toronto, Canada
| | - Xavier Campos-Moller
- Ophthalmologist, Western Health Eye Care Centre, Corner Brook, Newfoundland, Canada
| | - Hady Saheb
- Ophthalmologist, Department of Ophthalmology, McGill University, Montreal, Quebec, Canada
| | - Iqbal Ike K Ahmed
- Ophthalmologist, Department of Ophthalmology and Vision Sciences, University of Toronto, Mississauga, Ontario, Canada
| |
Collapse
|
31
|
|
32
|
Singh K, Mutreja A, Bhattacharyya M, Dangda S, Jaisingh K. Bilateral Phacomatosis Pigmentovascularis in a Young Male with Developmental Glaucoma and Varicose Veins. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1251] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
33
|
Popovic M, Campos-Möller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1248] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
34
|
|
35
|
Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis. PLoS One 2017; 12:e0183142. [PMID: 28850575 PMCID: PMC5574616 DOI: 10.1371/journal.pone.0183142] [Citation(s) in RCA: 282] [Impact Index Per Article: 40.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2016] [Accepted: 07/31/2017] [Indexed: 11/19/2022] Open
Abstract
Background MIGS have been developed as a surgical alternative for glaucomatous patients. Purpose To analyze the change in intraocular pressure (IOP) and glaucoma medications using different MIGS devices (Trabectome, iStent, Excimer Laser Trabeculotomy (ELT), iStent Supra, CyPass, XEN, Hydrus, Fugo Blade, Ab interno canaloplasty, Goniscopy-assisted transluminal trabeculotomy) as a solo procedure or in association with phacoemulsification. Methods Randomized control trials (RCT) and non-RCT (non randomized comparative studies, NRS, and before-after studies) were included. Studies with at least one year of follow-up in patients affected by primary open angle glaucoma, pseudoexfoliative glaucoma or pigmentary glaucoma were considered. Risk of Bias assessment was performed using the Cochrane Risk of Bias and the ROBINS-I tools. The main outcome was the effect of MIGS devices compared to medical therapy, cataract surgery, other glaucoma surgeries and other MIGS on both IOP and use of glaucoma medications 12 months after surgery. Outcomes measures were the mean difference in the change of IOP and glaucoma medication compared to baseline at one and two years and all ocular adverse events. The current meta-analysis is registered on PROSPERO (reference n° CRD42016037280). Results Over a total of 3,069 studies, nine RCT and 21 case series with a total of 2.928 eyes were included. Main concerns about risk of bias in RCTs were lack of blinding, allocation concealment and attrition bias while in non-RCTs they were represented by patients’ selection, masking of participants and co-intervention management. Limited evidence was found based on both RCTs and non RCTs that compared MIGS surgery with medical therapy or other MIGS. In before-after series, MIGS surgery seemed effective in lowering both IOP and glaucoma drug use. MIGS showed a good safety profile: IOP spikes were the most frequent complications and no cases of infection or BCVA loss due to glaucoma were reported. Conclusions Although MIGS seem efficient in the reduction of the IOP and glaucoma medication and show good safety profile, this evidence is mainly derived from non-comparative studies and further, good quality RCTs are warranted.
Collapse
|
36
|
Safety and Efficacy of Microinvasive Glaucoma Surgery. J Ophthalmol 2017; 2017:3182935. [PMID: 28512578 PMCID: PMC5420434 DOI: 10.1155/2017/3182935] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Accepted: 03/20/2017] [Indexed: 01/27/2023] Open
Abstract
Microinvasive glaucoma surgery (MIGS) is emerging as a new therapeutic option for glaucoma patients who wish to reduce their medication burden and avoid the postoperative complications of conventional glaucoma filtration surgery. These devices differ in terms of their efficacy and safety profile. Schlemm's canal devices have the most favorable safety profile at the compromise of modest efficacy, while subconjunctival and suprachoroidal devices are potentially more effective at lowering the intraocular pressure at the expense of a higher rate of complications. This review consolidates the latest evidence on the efficacy and safety of the MIGS devices in clinical use and provides an overview on upcoming devices which would likely also become viable treatment options in the near future. These clinical data would assist a glaucoma surgeon in selecting the most appropriate MIGS device for each patient based on the glaucoma severity and patient expectations.
Collapse
|
37
|
Chang DF, Donnenfeld ED, Katz LJ, Voskanyan L, Ahmed IIK, Samuelson TW, Giamporcaro JE, Hornbeak DM, Solomon KD. Efficacy of two trabecular micro-bypass stents combined with topical travoprost in open-angle glaucoma not controlled on two preoperative medications: 3-year follow-up. Clin Ophthalmol 2017; 11:523-528. [PMID: 28352151 PMCID: PMC5359133 DOI: 10.2147/opth.s121041] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To evaluate the long-term intraocular pressure (IOP)-lowering effect and safety parameters following treatment with two trabecular micro-bypass stents and topical prostaglandin in phakic eyes with open-angle glaucoma (OAG) not controlled on two preoperative medications. Methods This prospective, single-arm, unmasked study enrolled 39 qualified phakic eyes with OAG not controlled on 2 medications, preoperative medicated IOP of 18–30 mmHg, and IOP following medication washout of 22–38 mmHg. Two trabecular micro-bypass stents were implanted as a standalone procedure, and travoprost was started on postoperative day 1. Evaluations included IOP, best-corrected visual acuity, medication use, fundus and slit-lamp examinations, visual field, cup:disc ratio, central corneal thickness, and ocular complications. Data through 18 months were summarized previously. Thirty-seven of the original 39 subjects have been followed for 3 years postoperatively; follow-up is continuing for 5 years. Results At 3 years postoperative, 97% of eyes had achieved an IOP reduction of ≥20% from baseline with a reduction of 1 medication. Eighty-six percent of eyes had IOP of ≤18 mmHg with a reduction of 1 medication. Mean medicated IOP decreased to 14.0±2.6 mmHg on 1 medication versus 22.4±2.3 mmHg on 2 medications preoperatively. The mean unmedicated IOP decreased to 17.7±1.7 mmHg at 37 months from 25.3±1.9 mmHg preoperatively. Long-term postoperative adverse events included cataract surgery in 3 eyes due to cataract progression, and trabeculectomy in 1 eye due to uncontrolled IOP of 23 mmHg. No intraoperative or device-related adverse events occurred. Conclusion Significant and sustained reduction in IOP and medications with a favorable safety profile was shown through 3 years after implantation of 2 trabecular micro-bypass stents combined with postoperative travoprost in phakic OAG eyes uncontrolled on 2 preoperative medications. These findings demonstrate the long-term performance and safety of trabecular bypass stents in combination with topical prostaglandin for OAG patients.
Collapse
Affiliation(s)
| | | | - L Jay Katz
- Department of Ophthalmology, Wills Eye Hospital, Jefferson Medical College, Philadelphia, PA, USA
| | | | - Iqbal Ike K Ahmed
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada
| | | | | | | | | |
Collapse
|
38
|
Kaplowitz K, Abazari A, Kronberg BP, Honkanen R, Loewen NA. Outcomes analysis of trabecular meshwork bypass devices. EXPERT REVIEW OF OPHTHALMOLOGY 2017. [DOI: 10.1080/17469899.2017.1259564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Kevin Kaplowitz
- Department of Ophthalmology, VA Loma Linda, Loma Linda, CA, USA
| | - Azin Abazari
- Department of Ophthalmology, State University of New York at Stony Brook, Stony Brook, NY, USA
| | | | - Robert Honkanen
- Department of Ophthalmology, State University of New York at Stony Brook, Stony Brook, NY, USA
| | - Nils A Loewen
- Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| |
Collapse
|
39
|
Abstract
PURPOSE In this case report, we describe the successful implantation of multiple trabecular micro-bypass iStents in a patient with necrotizing scleritis. DESIGN The study design is a case report. PARTICIPANTS The participant was a patient who underwent multiple micro-bypass iStent surgery. METHODS A 71-year-old man with primary open-angle glaucoma, diagnosed with necrotizing scleritis and treated with steroids consequently resulting in significantly elevated intraocular pressure in the right eye. RESULTS Following uncomplicated surgery, IOP was reduced from 42 to 12 mm Hg 18 months after surgery on 2 drops and prednisone 40 mg daily CONCLUSIONS:: iStents may be considered as a possible intervention to lower IOP in patients with necrotizing scleritis in whom traditional glaucoma surgery is challenging or contraindicated.
Collapse
|
40
|
Evaluation of a Trabecular Micro-Bypass Stent in Pseudophakic Patients With Open-Angle Glaucoma. J Glaucoma 2016; 25:896-900. [DOI: 10.1097/ijg.0000000000000529] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
41
|
Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study. J Ophthalmol 2016; 2016:1056573. [PMID: 27882243 PMCID: PMC5108856 DOI: 10.1155/2016/1056573] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 09/09/2016] [Accepted: 10/05/2016] [Indexed: 11/22/2022] Open
Abstract
Purpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA) combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT). Methods. A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle glaucoma or OHT and cataract. Patients underwent cataract surgery along with the implant of two iStent inject devices. Outcome measures were intraocular pressure (IOP), topical hypotensive medications required, and best-corrected visual acuity (BCVA). Results. 20 patients were enrolled. Mean follow-up was 47.4 ± 18.46 months. Mean baseline IOP was 19.95 ± 3.71 mmHg with medication and 26 ± 3.11 mmHg after washout. Mean end-follow-up IOP was 16.25 ± 1.99 mmHg, representing an IOP decrease of 36.92%, 9.74 ± 3.14 mmHg (P < 0.001), from baseline washout IOP. The mean number of medications was significantly reduced from 1.3 ± 0.66 to 0.75 ± 0.79 (P = 0.017). 45% of patients were medication-free by the end of follow-up. Mean logMAR BCVA improved significantly from 0.42 ± 0.16 to 0.18 ± 0.16 (P < 0.001). No complications of surgery were observed. Conclusion. The iStent inject device combined with cataract surgery served to significantly reduce both IOP and medication use in the long term in patients with coexistent open-angle glaucoma or ocular hypertension (OHT) and cataract.
Collapse
|
42
|
Gallardo MJ, Supnet RA, Giamporcaro JE, Hornbeak DM. Outcomes of combined trabecular micro-bypass and phacoemulsification in a predominantly Hispanic patient population. Clin Ophthalmol 2016; 10:1931-1937. [PMID: 27784981 PMCID: PMC5067003 DOI: 10.2147/opth.s117403] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
PURPOSE The purpose of this study was to evaluate intraocular pressure (IOP) and topical ocular hypotensive medication burden at 12 months postoperatively in a predominantly Hispanic patient population with primary open-angle glaucoma each implanted with one trabecular micro-bypass stent during cataract surgery. METHODS This was a retrospective, consecutive case series. The main objective was to assess reduction of IOP and/or medication burden in all eyes at the 12-month postoperative exam. A secondary objective was to assess outcomes in 3 subgroups, distinguished preoperatively by IOP control and by medication burden (suboptimal or maximum therapy) and with different treatment goals. Group 1 had medication-controlled IOP and goal to reduce medications while maintaining IOP control (n=65); Group 2 had uncontrolled IOP on ≤2 medications and goal to reduce IOP and maintain/reduce medication burden (n=31); and Group 3 had uncontrolled IOP on ≥3 medications and goal to reduce IOP and avoid filtering surgery (n=38). Evaluations included IOP, medication use, cup-to-disc ratio, visual fields, complications, and interventions. One hundred subjects (134 eyes) have been followed for 12 months. RESULTS Most patients (80%) were Hispanic and had moderate or severe glaucoma (87%). At 12 months, mean IOP reduced to 12.9 mmHg vs 16.5 mmHg preoperatively; 92% had an IOP ≤15 mmHg at 12 months (99% had ≤18 mmHg). Mean medication burden had decreased to 0.9 vs 2.3 preoperatively. At the 12-month time point, 94% of all eyes achieved their predefined treatment goal of reduced IOP and/or medications. Reductions in medication burden for Group 1, and in IOP for Groups 2 and 3, were highly statistically significant (P<0.001). Two eyes in Group 3 had filtering surgery; the remaining 95% avoided such treatment. No other complications were reported. CONCLUSION This mainly Hispanic population with predominantly moderate or severe glaucoma had substantial reduction of IOP and medication and favorable safety for 12 months following stent implantation during cataract surgery, with treatment success achieved in all 3 subgroups. These data show this stent technology to be effective in Hispanic eyes with more advanced disease.
Collapse
Affiliation(s)
- Mark J Gallardo
- El Paso Eye Surgeons, PA, El Paso; Department of Ophthalmology, University of Texas Health Science Center at San Antonio, San Antonio, TX
| | | | - Jane Ellen Giamporcaro
- Division of Clinical Research and Medical Affairs, Glaukos Corporation, Laguna Hills, CA, USA
| | - Dana M Hornbeak
- Division of Clinical Research and Medical Affairs, Glaukos Corporation, Laguna Hills, CA, USA
| |
Collapse
|
43
|
Ferguson TJ, Berdahl JP, Schweitzer JA, Sudhagoni RG. Clinical evaluation of a trabecular microbypass stent with phacoemulsification in patients with open-angle glaucoma and cataract. Clin Ophthalmol 2016; 10:1767-1773. [PMID: 27695280 PMCID: PMC5028087 DOI: 10.2147/opth.s114306] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate the safety and efficacy of the iStent trabecular microbypass stent in combination with cataract surgery in patients with open-angle glaucoma (OAG). Methods Retrospective, consecutive case series from October 2012 to December 2015 with no exclusion criteria. The series comprised of 350 eyes with OAG and cataract. Data were collected both preoperatively and postoperatively at day 1 week 1, months 1, 3, 6, 12, 18, and 24. Data included intraocular pressure (IOP), number of glaucoma medications, visual acuity, the incidence of postoperative IOP pressure spikes of greater than ≥15 mmHg at any time point, and need for additional surgery. Results The mean preoperative IOP was 19.13±6.34 mmHg. At 2 years postoperation, mean IOP was 15.17±3.53 mmHg (P<0.0001). The mean number of glaucoma medications was 1.19±1.00 preoperatively and 0.61±0.96 (P<0.0001) at 2 years postoperation. At 1 day postoperatively, 31 eyes (12.4%) experienced an IOP increase of 15 mmHg above their baseline IOP that responded to topical therapy. Two patients required additional tube shunt surgery. Conclusion The insertion of the iStent trabecular microbypass stent in combination with cataract surgery effectively lowers IOP in OAG patients. The magnitude of IOP reduction was more significant in patients with higher preoperative pressure. Medication use was also significantly reduced postoperatively. The safety profile appears favorable with a low rate of IOP spikes and only two eyes (<1%) requiring additional surgery.
Collapse
Affiliation(s)
- Tanner J Ferguson
- Sanford School of Medicine, University of South Dakota, Sanford School of Medicine, Sioux Falls, SD, USA
| | | | | | - Ramu G Sudhagoni
- Sanford School of Medicine, University of South Dakota, Sanford School of Medicine, Sioux Falls, SD, USA
| |
Collapse
|
44
|
Vold SD, Voskanyan L, Tetz M, Auffarth G, Masood I, Au L, Ahmed IIK, Saheb H. Newly Diagnosed Primary Open-Angle Glaucoma Randomized to 2 Trabecular Bypass Stents or Prostaglandin: Outcomes Through 36 Months. Ophthalmol Ther 2016; 5:161-172. [PMID: 27619225 PMCID: PMC5125126 DOI: 10.1007/s40123-016-0065-3] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Indexed: 12/04/2022] Open
Abstract
Purpose To examine outcomes through 36 months in phakic eyes with newly diagnosed primary open-angle glaucoma (POAG) naïve to therapy randomized to treatment with two trabecular micro-bypass stents or topical prostaglandin. Methods Subjects with POAG naïve to therapy, with intraocular pressure (IOP) ≥21 and ≤40 mmHg, were randomized to implantation of two stents or travoprost. Additional medication was to be prescribed post-treatment for elevated IOP or glaucomatous optic nerve findings. Of 101 randomized subjects, 100 subjects were followed for 24 months and 73 subjects were followed for 36 months. Follow-up on all subjects is ongoing. Results In this randomized cohort of 101 POAG subjects, 54 subjects underwent 2-stent surgery and 47 received topical travoprost. Mean pre-treatment IOP was 25.5 ± 2.5 mmHg in stent-treated eyes and 25.1 ± 4.6 mmHg in medication-treated eyes. By 3 years, mean IOP was 14.6 mmHg in stent eyes (with medication added in 6 eyes) and 15.3 mmHg in travoprost eyes (with a second medication added in 11 eyes). In the subset of eyes that did not require additional medical therapy, mean IOP was 14.5 mmHg and 15.7 mmHg in the respective groups. Ninety-one percent of stent eyes had 3-year IOP ≤18 mmHg without additional therapy (62% ≤ 15 mmHg) and 79% of travoprost eyes had 3-year IOP ≤18 mmHg (21% ≤ 15 mmHg). Safety was favorable in both groups. Conclusions In this prospective, randomized comparison of subjects with newly diagnosed POAG naïve to therapy, substantial IOP reduction with a favorable low complication rate was shown through 3 years after either 2 trabecular stents implanted as the sole procedure or topical travoprost therapy. These data suggest 2-stent implantation may be a viable initial treatment option comparable to topical prostaglandin in newly diagnosed POAG patients. Trial registration: ClinicalTrials.gov identifier, NCT01443988. Funding Glaukos Corporation, Laguna Hills, CA. Electronic supplementary material The online version of this article (doi:10.1007/s40123-016-0065-3) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
| | | | - Manfred Tetz
- Berlin Eye Research Institute and Augenklinik Spreebogen, Berlin, Germany
| | | | | | - Leon Au
- Manchester Royal Eye Hospital, Manchester, UK
| | | | | |
Collapse
|
45
|
A New Expander for Schlemm Canal Surgery in Primary Open-angle Glaucoma—Interim Clinical Results. J Glaucoma 2016; 25:657-62. [DOI: 10.1097/ijg.0000000000000397] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
46
|
iStent® Trabecular Microbypass Stent: An Update. J Ophthalmol 2016; 2016:2731856. [PMID: 27413541 PMCID: PMC4931099 DOI: 10.1155/2016/2731856] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2015] [Accepted: 05/15/2016] [Indexed: 11/28/2022] Open
Abstract
Due to the high rates of complications and failure experienced with current glaucoma procedures, there is a continuous search for a safer and more effective glaucoma surgery. A new class of procedures termed minimally invasive glaucoma surgeries (MIGS) aim to fill this void by offering an alternative method of IOP reduction associated with markedly reduced complication rates and shorter recovery times. The iStent, a trabecular microbypass stent, is a MIGS device that has quickly gained popularity. The device allows aqueous humor to directly drain from the anterior chamber into Schlemm's canal by bypassing an obstructed trabecular meshwork. This review examines publications about the iStent, focusing on the device's efficacy, safety, and cost when a single iStent or multiple iStents are implanted in combination with cataract surgery or as a solo procedure. Current data suggest that the iStent is a safe and effective tool in the management of mild-to-moderate glaucoma, notable for its limited complications and absence of serious adverse events following implantation. As valuable experience is gained performing ab interno MIGS, increasing familiarity with angle anatomy and iStent placement, and as newer stent designs are developed, there is promise of continual improvement in the surgical management of glaucoma.
Collapse
|
47
|
Managing coexistent cataract and glaucoma with iStent. Surv Ophthalmol 2016; 62:706-711. [PMID: 27217122 DOI: 10.1016/j.survophthal.2016.01.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 01/09/2016] [Accepted: 01/15/2016] [Indexed: 11/24/2022]
Abstract
The iStent is an intraocular implant that resides within Schlemm canal and allows for direct bypass of the trabecular meshwork by aqueous fluid. It is one of several procedures termed microinvasive glaucoma surgery. The prominence of microinvasive glaucoma surgery is growing because of its role in lowering intraocular pressure in mild to moderate glaucoma combined with its favorable safety profile. With transcleral glaucoma filtering surgery, there is an increased potential for significant complications including hypotony, suprachoroidal hemorrhage, and long-term risk of endophthalmitis. In comparison, the iStent minimizes this risk and has been shown to be similar to cataract surgery in terms of associated complications. As will be discussed, multiple publications have addressed both the safety and efficacy of the implant. This review additionally presents an overview of implantation technique as well as what to expect postoperatively. Looking forward, the second-generation models may ease implantation and the use of multiple stents may potentially play a role in more advanced disease.
Collapse
|
48
|
Jo S. Glaucoma Schlemm's canal stent insertion: a systematic review. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION 2016. [DOI: 10.5124/jkma.2016.59.8.637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Affiliation(s)
- Sunyoung Jo
- Division for New Health Technology Assessment, National Evidence-based Healthcare Collaborating Agency, Seoul, Korea
| |
Collapse
|
49
|
Donnenfeld ED, Solomon KD, Voskanyan L, Chang DF, Samuelson TW, Ahmed IIK, Katz LJ. A prospective 3-year follow-up trial of implantation of two trabecular microbypass stents in open-angle glaucoma. Clin Ophthalmol 2015; 9:2057-65. [PMID: 26604675 PMCID: PMC4639560 DOI: 10.2147/opth.s91732] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Purpose To evaluate 3-year safety and intraocular pressure (IOP) following two trabecular microbypass stents in phakic and pseudophakic subjects with open-angle glaucoma (OAG) not controlled on preoperative medication. Patients and methods In this prospective pilot study, phakic or pseudophakic subjects with OAG and IOP between 18 mmHg and 30 mmHg on one preoperative topical ocular hypotensive medication underwent medication washout. Thirty-nine qualified subjects with preoperative unmedicated IOP ≥22 mmHg and ≤38 mmHg received two stents. Postoperative examinations were scheduled at Day 1, Week 1, Months 1, 3, 6, and 12, and semiannually through Month 60. Ocular hypotensive medication was considered if postoperative IOP exceeded 21 mmHg. IOP, medication use, and safety were assessed at each visit. Subject follow-up through Month 36 was completed. Results Thirty-six eyes (92.3%; 95% confidence interval [CI] 79.1%, 98.4%) achieved the primary efficacy end point of Month 12 reduction in IOP ≥20% from baseline (unmedicated IOP) without ocular hypotensive medication. Four subjects required medication during the Month 36 follow-up period. Mean IOP at 36 months for subjects not taking medication was 15.2 mmHg. At 36 months, subjects sustained mean IOP decrease of 9.1±2.7 mmHg (95% CI 8.0 mmHg, 10.14 mmHg), or 37% IOP reduction, from unmedicated baseline IOP. Compared to preoperative medicated IOP, subjects had mean reduction at Month 36 of 5.5±2.7 mmHg (95% CI 4.5 mmHg, 6.6 mmHg), or 26% reduction. Both measures of IOP reduction were highly significant (P<0.001). Other than one case of early postoperative hyphema that resolved at 1 week, no postoperative adverse events were attributed to stent implantation. Conclusion In a pilot study, two trabecular microbypass stents to treat OAG subjects on one preoperative medication provided statistically significant, sustained, and safe reduction of IOP to ≤15 mmHg without medication through 36 months.
Collapse
Affiliation(s)
| | | | | | | | | | | | - L Jay Katz
- Wills Eye Hospital, Jefferson Medical College, Philadelphia, PA, USA
| |
Collapse
|
50
|
Kaplowitz K, Kuei A, Klenofsky B, Abazari A, Honkanen R. The use of endoscopic cyclophotocoagulation for moderate to advanced glaucoma. Acta Ophthalmol 2015; 93:395-401. [PMID: 25123160 DOI: 10.1111/aos.12529] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Accepted: 07/10/2014] [Indexed: 11/30/2022]
Abstract
Endoscopic Cyclophotocoagulation (ECP) is a glaucoma surgery designed to reduce the intraocular pressure (IOP) by partially ablating the ciliary processes to decrease aqueous humour production and secretion. The aim of this paper is to review the literature regarding the background, indications and results of the surgery. Although there are case reports of visually devastating complications, including persistent hypotony and phthisis, the use of ECP is often reported in eyes with advanced diseases. When compared with both trabeculectomy and aqueous shunt implantation, the visual outcomes were better with ECP while the IOP outcomes were very similar. The evidence supports ECP as a very effective surgical option in recalcitrant glaucoma while some evidence supports its safety for use as a primary procedure.
Collapse
Affiliation(s)
- Kevin Kaplowitz
- Department of Ophthalmology; Stony Brook University Medical Center; Stony Brook New York USA
| | - Andrew Kuei
- Department of Ophthalmology; Stony Brook University Medical Center; Stony Brook New York USA
| | - Britany Klenofsky
- Department of Ophthalmology; Stony Brook University Medical Center; Stony Brook New York USA
| | - Azin Abazari
- Department of Ophthalmology; Stony Brook University Medical Center; Stony Brook New York USA
| | - Robert Honkanen
- Department of Ophthalmology; Stony Brook University Medical Center; Stony Brook New York USA
| |
Collapse
|