1
|
Assaf AH, Samy H, Fawky N, Kamel MA. Evaluation of Visual Outcomes, Postoperative Angle Alpha, and Angle Kappa After Implantation of Isofocal Intraocular Lenses. Clin Ophthalmol 2024; 18:2879-2890. [PMID: 39415938 PMCID: PMC11480658 DOI: 10.2147/opth.s478471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 09/30/2024] [Indexed: 10/19/2024] Open
Abstract
Purpose To evaluate the effect of angles kappa and alpha on the visual outcomes after implantation of isofocal intraocular lens (IOL) during cataract surgery. Methods This prospective study involved 66 eyes undergoing cataract surgery with Isopure IOLs. Exclusion criteria comprised irregular corneal astigmatism exceeding 1.0D, and ocular co-morbidities affecting visual outcomes post-surgery. Evaluation parameters included postoperative refraction, uncorrected and corrected-distance visual acuity (UDVA, CDVA), uncorrected intermediate visual acuity (UIVA), and distance-corrected intermediate visual acuity (DCIVA) at 80 cm. Additionally, postoperative angles alpha, kappa, and wavefront aberrations at a 3-mm pupil using ray tracing were assessed post-surgery at least 60 days later. Results Patients had a mean age of 64.48 ± 9.92 years. Mean postoperative manifest refraction spherical equivalent (MRSE) was -0.21 ± 0.27 D. Mean UDVA and CDVA were LogMAR 0.06 ± 0.04 and 0.02 ± 0.06, respectively. Mean UIVA LogMAR 0.32 ± 0.08 while mean DCIVA was LogMAR 0.29 ± 0.08. Postoperative angles kappa and alpha were 0.39 ± 0.14 mm and 0.45 ± 0.15 mm, respectively. Mean postoperative ocular RMS higher-order aberrations (HOAs) 0.23 ± 0.08. Spherical aberration, coma, and trefoil averaged 0.05 ± 0.07, 0.12 ± 0.03, and 0.07 ± 0.03, respectively. No significant correlations were observed between postoperative angle kappa and alpha with UDVA, CDVA, or HOAs. A non-significant weak positive correlation was noted between angle kappa and UIVA/DCIVA, while no correlation was found between angle alpha and UIVA/DCIVA. Conclusion No substantial correlations were found between various postoperative angles kappa and alpha values and postoperative visual acuity metrics (UDVA, CDVA, UIVA, and DCIVA) or higher order ocular aberrations (including, spherical aberration, coma, and trefoil with a 3.0 mm diameter) in pseudophakic eyes implanted with isofocal intraocular lenses (IOLs).
Collapse
Affiliation(s)
- Ahmed Hassan Assaf
- Department of Ophthalmology, Ain Shams University, Cairo, Egypt
- Watany Eye Hospital, Cairo, Egypt
| | | | | | | |
Collapse
|
2
|
Ribeiro F, Piñero DP, Dick HB, Findl O, Cochener B, Kohnen T. Should enhanced monofocal intraocular lenses be the standard of care? An evidence-based appraisal by the ESCRS Functional Vision Working Group. J Cataract Refract Surg 2024; 50:789-793. [PMID: 39083406 DOI: 10.1097/j.jcrs.0000000000001479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 05/06/2024] [Indexed: 08/02/2024]
Affiliation(s)
- Filomena Ribeiro
- From the Hospital da Luz, Lisbon University, Lisbon, Portugal (Ribeiro); Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain (Piñero); Ruhr University Eye Hospital, Bochum, Germany (Dick); Vienna Institute for Research in Ocular Surgery (VIROS), Department of Ophthalmology, Hanusch Hospital, Vienna, Austria (Findl); Service d'ophtalmologie, CHRU de Brest-Hôpital Morvan, Brest, France (Cochener); Department of Ophthalmology, Goethe University, Frankfurt, Germany (Kohnen)
| | | | | | | | | | | |
Collapse
|
3
|
Danzinger V, Schartmüller D, Lisy M, Schranz M, Schwarzenbacher L, Abela-Formanek C, Menapace R, Leydolt C. Intraindividual Comparison of an Enhanced Monofocal and an Aspheric Monofocal Intraocular Lens of the Same Platform. Am J Ophthalmol 2024; 261:95-102. [PMID: 37944686 DOI: 10.1016/j.ajo.2023.11.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 11/03/2023] [Accepted: 11/03/2023] [Indexed: 11/12/2023]
Abstract
PURPOSE To compare intraindividual differences in visual performance of a monofocal and enhanced monofocal intraocular lens (IOL) of the same platform. DESIGN Prospective, interventional, fellow-eye comparison clinical study. METHODS In total, 55 patients (110 eyes) with bilateral age-related cataract were enrolled. All patients received a monofocal ZCB00 IOL in the dominant and an enhanced monofocal Eyhance ICB00 IOL in the nondominant eye. After 2 to 4 months, monocular best-corrected distant visual acuity (BCDVA), distance-corrected intermediate visual acuity (DCIVA), distance-corrected near visual acuity (DCNVA), contrast visual acuity, monocular defocus curves, internal higher-order aberrations (HOAs) and spherical aberrations (SA), decentration, and tilt were compared. RESULTS The monocular mean BCDVA, DCIVA at 80 cm and 66 cm, and DCNVA were -0.03 ± 0.07, 0.24 ± 0.12, 0.32 ± 0.13, and 0.50 ± 0.13 logarithm of the minimum angle of resolution for the enhanced ICB00 and -0.06 ± 0.06 (P = .014), 0.30 ± 0.11 (P = .005), 0.38 ± 0.12 (P = .004), and 0.55 ± 0.14 (P = .034) logarithm of the minimum angle of resolution for the ZCB00, respectively. Internal HOAs (P = .001) and negative SA (P < .001) were increased with the ICB00 at 3 mm and comparable at 5 mm (P > .05). Contrast acuity, tilt, and decentration were similar (P > .05). CONCLUSIONS Significantly increased monocular DCIVA at 80 cm and 66 cm and DCNVA at 40 cm were observed with the enhanced ICB00 IOL, and the ZCB00 IOL demonstrated better BCDVA. This would result in a mean gain of 2 to 3 Early Treatment of Diabetic Retinopathy Study letters at near and intermediate distance. Monocular defocus curves displayed highest differences of 5 Early Treatment of Diabetic Retinopathy Study letters at -1.25 diopters (D) and -1.50 D levels of defocus and a depth of focus of 1.23 D for the ICB00 IOL and 0.94 D for the ZCB00 IOL. Decentration, tilt, and HOAs were generally low.
Collapse
Affiliation(s)
- Victor Danzinger
- From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Daniel Schartmüller
- From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Marcus Lisy
- From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Markus Schranz
- From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Luca Schwarzenbacher
- From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Claudette Abela-Formanek
- From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Rupert Menapace
- From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Christina Leydolt
- From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria..
| |
Collapse
|
4
|
Dell SJ, Hannan SJ, Venter JA, Teenan D, Hannan NC, Raju D, Berry CW, Kiss HJ, Schallhorn JM. Comparative Analysis of Clinical and Patient-Reported Outcomes of a New Enhanced Monofocal IOL and a Conventional Monofocal IOL. Clin Ophthalmol 2024; 18:1157-1169. [PMID: 38707771 PMCID: PMC11070167 DOI: 10.2147/opth.s456332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Accepted: 04/05/2024] [Indexed: 05/07/2024] Open
Abstract
Purpose To compare the outcomes of the Tecnis Eyhance ICB00 IOL, designed to enhance intermediate vision, to a conventional Tecnis Monofocal ZCB00 IOL. Methods This retrospective analysis compared two cohorts of patients undergoing lens replacement surgery with bilateral implantation of the Tecnis ICB00 or the Tecnis ZCB00 IOL (383 patients in each group). Monocular and binocular uncorrected distance (UDVA), intermediate (UIVA; 66cm), and near (UNVA; 40cm) visual acuities, refractive predictability, and patient-reported outcomes were compared. A sub-analysis of patients with the Eyhance IOL was performed to compare patients who achieved bilateral emmetropia to those with mini-monovision. One-month postoperative outcomes were analyzed. Results Both groups had comparable UDVA outcomes. On average, both monocular and binocular UIVAs were approximately one Snellen line better in patients implanted with Eyhance IOL (monocular UIVA: ICB00 0.23 ± 0.18 logMAR, ZCB00 0.33 ± 0.19 logMAR; binocular UIVA: ICB00 0.18 ± 0.18 logMAR, ZCB00 0.26 ± 0.20 logMAR, p < 0.01). Likewise, the mean UNVA was also one Snellen line better with the ICB00 model (monocular UNVA: ICB00 0.51 ± 0.20 logMAR, ZCB00 0.61 ± 0.18 logMAR; binocular UNVA: ICB00 0.42 ± 0.19 logMAR, ZCB00 0.51 ± 0.22 logMAR, p < 0.01). There was no difference between the two groups in overall satisfaction or visual phenomena. A subgroup of patients who achieved mini-monovision with Eyhance IOL had, on average, one Snellen line better UIVA and UNVA compared to patients with bilateral emmetropia. Conclusion Patients receiving the enhanced monofocal IOL had better intermediate and near vision compared to those receiving the conventional monofocal IOL, with similar levels of patient-reported photic phenomena in both groups.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Julie M Schallhorn
- University of California, San Francisco, Department of Ophthalmology, San Francisco, CA, USA
- F.I. Proctor Foundation, University of California, San Francisco, CA, USA
| |
Collapse
|
5
|
Sandoval HP, Potvin R, Solomon KD. Comparing Visual Performance and Subjective Outcomes with an Enhanced Monofocal Intraocular Lens When Targeted for Emmetropia or Monovision. Clin Ophthalmol 2023; 17:3693-3702. [PMID: 38058694 PMCID: PMC10697088 DOI: 10.2147/opth.s442752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Accepted: 11/29/2023] [Indexed: 12/08/2023] Open
Abstract
Purpose To evaluate relative visual performance and subjective outcomes after implantation of the TECNIS Eyhance™ intraocular lens (IOL) targeted for bilateral emmetropia or monovision. Methods This was a prospective, single-center randomized, patient-masked trial. Patients were implanted with the enhanced IOL targeted for bilateral emmetropia or slight monovision (-0.75 D in the non-dominant eye). At 3 months the binocular visual acuity (VA) was measured at distance, intermediate and near, along with low contrast VA in photopic and mesopic conditions, and the distance corrected defocus curve. Questionnaires related to spectacle independence, satisfaction, visual symptoms, and functional vision were administered. Results Data from 71 subjects (34 Emmetropia, 37 Monovision) were analyzed. There was no difference in the mean uncorrected distance VA (p = 0.11), but uncorrected intermediate and near VAs were one line better in the Monovision group (p = 0.02 and 0.01, respectively). Mesopic and photopic low contrast VA were similar between groups. There was a trend for less difficulty and higher satisfaction with near and intermediate vision in the Monovision group, but no significant differences in any of the subjective questionnaires. Difficulty reading was the most reported concern in both groups, though 93% of all subjects reported "little" or "no" difficulty with daily activities. Overall, 82% of subjects were "completely" or "very" happy with their lens choice. Conclusion Using this enhanced IOL with slight monovision in the non-dominant eye increased intermediate and near VA with no apparent effect on low contrast distance VA, subjective visual quality, or satisfaction.
Collapse
|
6
|
De Rojas JO, Sandoval HP, Potvin R, Solomon KD. Visual Outcomes, Quality of Vision, Patient Satisfaction and Spectacle Independence After Bilateral Implantation of the Synergy™ Intraocular Lens. Clin Ophthalmol 2023; 17:2277-2285. [PMID: 37581096 PMCID: PMC10423583 DOI: 10.2147/opth.s421185] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 06/26/2023] [Indexed: 08/16/2023] Open
Abstract
Purpose To evaluate vision, visual quality, patient satisfaction and spectacle independence after bilateral implantation of the TECNIS Synergy™ intraocular lens. Setting Two clinical practices in the USA. Design Ambispective unmasked non-randomized clinical trial. Methods Patients with a history of uneventful bilateral femtosecond laser assisted cataract surgery with the study IOL implanted, targeted for emmetropia, at least 3 months prior to the study visit were enrolled. Monocular and binocular visual acuity (VA) were measured at distance, intermediate and near, along with binocular mesopic VA. Low contrast binocular VA and reading speed in mesopic and photopic conditions were also measured. Patient satisfaction, spectacle independence, visual symptoms, and functional vision questionnaires were completed. Results Results from 52 subjects were available for analysis. Mean binocular unaided visual acuity was ~0.1 logMAR (20/20) from distance to 33 cm, with 81% of subjects having 0.2 logMAR (20/25) vision or better at all test distances and 92% reporting never needing glasses at any distance. Average reading speed at 40 cm was only 10 words/minute slower in dim light (p = 0.03). Mesopic and low contrast acuity appeared good. Halos were the most frequent and bothersome visual disturbances, with the greatest effect on driving at night. Eighty-eight percent of subjects reported being "completely" or "mostly" satisfied with their overall unaided vision. Conclusion This hybrid technology IOL provided a range of binocular visual acuity from distance to 33 cm and good functional vision, even in dim light. Patients should be advised of the likelihood of visual disturbances, particularly halos.
Collapse
|
7
|
Fernández J, Rocha-de-Lossada C, Zamorano-Martín F, Rodríguez-Calvo-de-Mora M, Rodríguez-Vallejo M. Positioning of enhanced monofocal intraocular lenses between conventional monofocal and extended depth of focus lenses: a scoping review. BMC Ophthalmol 2023; 23:101. [PMID: 36918799 PMCID: PMC10015679 DOI: 10.1186/s12886-023-02844-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 03/06/2023] [Indexed: 03/15/2023] Open
Abstract
BACKGROUND New intraocular lenses (IOLs) have emerged since the originally coined monofocal and multifocal IOLs. The extended depth of focus (EDoF) and enhanced monofocal IOLs (mono-EDoF) that have appeared in the last decade have caused some confusion in their classification. The aim of this review was to summarize the outcomes provided by mono-EDOF IOLs and to determine which of the endpoints, described by the American National Standard (ANSI) for EDoF IOLs, are fulfilled. METHODS The MEDLINE, EMBASE, and WEB OF SCIENCE databases were searched. Two independent reviewers screened the studies for inclusion and data extraction. The search strategy was limited to studies published between 2020 and 2022, but not by language. The results are presented as a narrative summary accompanied by tables, in alignment with the objectives of this scoping review. Compliance with the endpoints for clinical outcomes described in the American National Standard Z80.35-2018 (ANSI) for EDoF lenses was checked and additional endpoints were defined. RESULTS Two systematic reviews, 13 laboratory, 21 clinical, and two mixed studies were included. Tecnis Eyhance was the mono-EDOF with the highest volume of evidence to date. Although laboratory studies included other IOLs, clinical evidence for them is still scarce, with only one study of IsoPure compared to a standard monofocal IOL. Evidence in comparison to EDoF lenses is also scarce, even for Tecnis Eyhance, with only three studies including this lens in comparison to an EDoF lens. After evaluation of the ANSI criteria, agreement was found in the failure for the increase in depth of field equal to or greater than 0.5 D for a visual acuity (VA) level of 0.2 logMAR and none of the studies supported that the median monocular VA at intermediate distance was at least 0.2 logMAR. CONCLUSIONS Additional clinical evidence is required for other mono-EDOF IOLs beyond Tecnis Eyhance. Until the arrival of a standard classification, mono-EDOF should be better still classified as monofocal because the ANSI standards were not fully met.
Collapse
Affiliation(s)
- Joaquín Fernández
- Qvision. Ophthalmology Department, VITHAS Almería Hospital, 04120, Almería, Spain
| | - Carlos Rocha-de-Lossada
- Qvision. Ophthalmology Department, VITHAS Almería Hospital, 04120, Almería, Spain
- Ophthalmology Department, VITHAS Málaga. 29016, Málaga, Spain
- Hospital Regional Universitario de Málaga. Plaza del Hospital Civil, 29009, Málaga, S/N, Spain
- Departamento de Cirugía, Área de Oftalmología. Doctor Fedriani, Universidad de Sevilla, 41009, Sevilla, S/N, Spain
| | | | - Marina Rodríguez-Calvo-de-Mora
- Qvision. Ophthalmology Department, VITHAS Almería Hospital, 04120, Almería, Spain
- Ophthalmology Department, VITHAS Málaga. 29016, Málaga, Spain
- Hospital Regional Universitario de Málaga. Plaza del Hospital Civil, 29009, Málaga, S/N, Spain
| | | |
Collapse
|