Goldstein K, Tyndall W, Nickol ME, van der Merwe JM. Inclinometer use in primary total hip arthroplasty does not improve acetabular component positioning: a non-randomized control trial. ARTHROPLASTY 2024; 6:41. [PMID: 38965583 PMCID: PMC11229020 DOI: 10.1186/s42836-024-00258-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 04/26/2024] [Indexed: 07/06/2024] Open
Abstract
INTRODUCTION Total hip arthroplasty (THA) is a common surgical procedure that aims to relieve pain, improve function, and increase mobility in patients with hip joint pathology. One of the most challenging aspects of THA is to determine the correct angle of the acetabular component's placement. Intraoperative inclinometers have emerged as a promising tool to obtain accurate measurements of the acetabular component's inclination. The primary objective of this study was to evaluate the accuracy and efficacy of using intraoperative inclinometers for THA. METHODS This non-randomized control trial evaluated patients undergoing primary THA. Patients in the inclinometer group had an inclinometer used intraoperatively to measure acetabular component inclination, and patients in the control group had no inclinometer. Inclination and anteversion of the acetabular component were measured on postoperative radiographs. RESULTS A total of 223 patients were included in the study. The mean inclination angle of the acetabular cup was significantly higher in the inclinometer group (43.9° vs. 41.5°, P < 0.001). This difference was not clinically significant. There was no significant difference in anteversion. There were no significant differences in the number of patients within the safe zones for inclination or anteversion, or in the number of patients experiencing a dislocation. No correlation was found between inclinometer measurement and measured acetabular component inclination. Inclinometer use and body mass index (BMI) were the sole statistically significant factors in determining acetabular component inclination. CONCLUSIONS This study indicated no current benefit to inclinometer use during primary THA, as measured by inclination, anteversion, and dislocation rate. However, this might be confounded by subtle variations in patient positioning, which may be a strong area of study in the future.
Collapse
Affiliation(s)
- Kyle Goldstein
- Adult Reconstruction Subdivision, Orthopaedic Division, University of Saskatchewan, Saskatoon, SK, S7K0M5, Canada
| | - Wyatt Tyndall
- Adult Reconstruction Subdivision, Orthopaedic Division, University of Saskatchewan, Saskatoon, SK, S7K0M5, Canada
| | - Michaela E Nickol
- Adult Reconstruction Subdivision, Orthopaedic Division, University of Saskatchewan, Saskatoon, SK, S7K0M5, Canada
| | - Johannes M van der Merwe
- Adult Reconstruction Subdivision, Orthopaedic Division, University of Saskatchewan, Saskatoon, SK, S7K0M5, Canada.
| |
Collapse
|
2
|
Meermans G, Grammatopoulos G, Innmann M, Beverland D. Cup placement in primary total hip arthroplasty: how to get it right without navigation or robotics. EFORT Open Rev 2022; 7:365-374. [PMID: 35638598 PMCID: PMC9257731 DOI: 10.1530/eor-22-0025] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Acetabular component orientation and position are important factors in the short- and long-term outcomes of total hip arthroplasty. Different definitions of inclination and anteversion are used in the orthopaedic literature and surgeons should be aware of these differences and understand their relationships. There is no universal safe zone. Preoperative planning should be used to determine the optimum position and orientation of the cup and assess spinopelvic characteristics to adjust cup orientation accordingly. A peripheral reaming technique leads to a more accurate restoration of the centre of rotation with less variability compared with a standard reaming technique. Several intraoperative landmarks can be used to control the version of the cup, the most commonly used and studied is the transverse acetabular ligament. The use of an inclinometer reduces the variability associated with the use of freehand or mechanical alignment guides.
Collapse
|
5
|
van Duren BH, Royeca JM, Cunningham CM, Lamb JN, Brew CJ, Pandit H. Can the use of an inclinometer improve acetabular cup inclination in total hip arthroplasty? A review of the literature. Hip Int 2021; 31:609-617. [PMID: 32750263 PMCID: PMC8488637 DOI: 10.1177/1120700020946716] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The angle of acetabular (cup) radiographic inclination is an important measurement in total hip arthroplasty (THA) procedures. Abnormal radiographic inclination is associated with dislocation, edge loading and higher failure rates. Consistently achieving a satisfactory radiographic inclination remains a challenge. Inclinometers have been increasingly used over the last decade. This paper reviews the literature to determine whether using an inclinometer improves the accuracy of acetabular cup inclination in THA. METHODS A systematic literature search was performed. The following search terms were used: ('hip' OR 'hip replacement' OR 'hip arthroplasty' OR 'primary hip replacement' OR 'THR' OR 'THA' OR 'Acetabular cup Inclination') AND ('Inclinometer'). Titles and abstracts were screened for relevance. Both radiographic and operative inclination comparisons were included. RESULTS 7 studies met the inclusion criteria. 2 were randomised control trials with level I evidence, and the remaining studies were cohort studies with level III/IV evidence. 5 were clinical and 2 experimental. In total there were 16 cohorts: 7 using an inclinometer, 6 freehand, and 3 using MAG techniques. All studies comparing radiographic inclination and 1 of 2 studies comparing operative inclination showed an improvement in the attainment of the optimal inclination. Similarly, the use of an inclinometer showed a reduction in the number of outliers when compared to MAG and freehand techniques. DISCUSSION This review demonstrates that using an inclinometer improved the surgeon's ability to achieve their intended inclination (both operative and radiographic) and reduced the incidence of positioning outside the safe-zone. However, only 2 of the studies were randomised control trials and these resulted in opposing conclusions. Therefore, further studies looking at the use of inclinometers would prove useful in understanding their true benefit.
Collapse
Affiliation(s)
- Bernard H van Duren
- Leeds Orthopaedic and Trauma Sciences, Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK,Bernard H van Duren, Leeds Institute of Rheumatic and Musculoskeletal Medicine, 2nd Floor, Chapel Allerton Hospital, Chapeltown Road, Leeds, LS7 4SA, UK.
| | | | | | - Jonathan N Lamb
- Leeds Orthopaedic and Trauma Sciences, Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| | | | - Hemant Pandit
- Leeds Orthopaedic and Trauma Sciences, Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| |
Collapse
|
6
|
van Duren BH, Al Ashqar M, Lamb JN, Pandit HG, Brew C. A novel mechanical inclinometer device to measure acetabular cup inclination in total hip arthroplasty. J Med Eng Technol 2020; 44:481-488. [PMID: 33118407 DOI: 10.1080/03091902.2020.1825846] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
It is well recognised that acetabular cup orientation influences patient function and implant survival post-THR. Reliable intra-operative determination of cup orientation remains a challenge. We describe the design and testing of a novel mechanical inclinometer to measure intra-operative acetabular cup inclination. The aim was to design a generic inclinometer to measure acetabular inclination to within + 5° without requiring modification to existing instrumentation while remaining easy to handle, robust/reusable, and sterilizable. The device was drafted using CAD software, prototyped using a 3D printer and constructed using stainless steel. Two experiments were undertaken to test accuracy: (1) the absolute accuracy was tested; (2) placement of an acetabular component using the device was compared to a freehand technique using a sawbone pelvis. 18 surgeons were asked to place an uncemented acetabular cup in a saw bone pelvis to a target of 40°. The average root-mean-square error was 1.1° (SD: 0.9°). Comparison showed that with the freehand component placement 50% of the surgeons were outside the specified range (35°-45°) where all participants achieved placement within range when using the inclinometer. This work demonstrates that the design and initial testing of a mechanical inclinometer which is suitable for use in determining the acetabular cup inclination in THR.
Collapse
Affiliation(s)
- B H van Duren
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| | | | - J N Lamb
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| | - H G Pandit
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| | - C Brew
- Bradford Royal Infirmary, Bradford, UK
| |
Collapse
|
7
|
Clarke A, Pulikottil-Jacob R, Grove A, Freeman K, Mistry H, Tsertsvadze A, Connock M, Court R, Kandala NB, Costa M, Suri G, Metcalfe D, Crowther M, Morrow S, Johnson S, Sutcliffe P. Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): systematic review and economic evaluation. Health Technol Assess 2015; 19:1-668, vii-viii. [PMID: 25634033 DOI: 10.3310/hta19100] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Total hip replacement (THR) involves the replacement of a damaged hip joint with an artificial hip prosthesis. Resurfacing arthroplasty (RS) involves replacement of the joint surface of the femoral head with a metal surface covering. OBJECTIVES To undertake clinical effectiveness and cost-effectiveness analysis of different types of THR and RS for the treatment of pain and disability in people with end-stage arthritis of the hip, in particular to compare the clinical effectiveness and cost-effectiveness of (1) different types of primary THR and RS for people in whom both procedures are suitable and (2) different types of primary THR for people who are not suitable for hip RS. DATA SOURCES Electronic databases including MEDLINE, EMBASE, The Cochrane Library, Current Controlled Trials and UK Clinical Research Network (UKCRN) Portfolio Database were searched in December 2012, with searches limited to publications from 2008 and sample sizes of ≥ 100 participants. Reference lists and websites of manufacturers and professional organisations were also screened. REVIEW METHODS Systematic reviews of the literature were undertaken to appraise the clinical effectiveness and cost-effectiveness of different types of THR and RS for people with end-stage arthritis of the hip. Included randomised controlled trials (RCTs) and systematic reviews were data extracted and risk of bias and methodological quality were independently assessed by two reviewers using the Cochrane Collaboration risk of bias tool and the Assessment of Multiple Systematic Reviews (AMSTAR) tool. A Markov multistate model was developed for the economic evaluation of the technologies. Sensitivity analyses stratified by sex and controlled for age were carried out to assess the robustness of the results. RESULTS A total of 2469 records were screened of which 37 were included, representing 16 RCTs and eight systematic reviews. The mean post-THR Harris Hip Score measured at different follow-up times (from 6 months to 10 years) did not differ between THR groups, including between cross-linked polyethylene and traditional polyethylene cup liners (pooled mean difference 2.29, 95% confidence interval -0.88 to 5.45). Five systematic reviews reported evidence on different types of THR (cemented vs. cementless cup fixation and implant articulation materials) but these reviews were inconclusive. Eleven cost-effectiveness studies were included; four provided relevant cost and utility data for the model. Thirty registry studies were included, with no studies reporting better implant survival for RS than for all types of THR. For all analyses, mean costs for RS were higher than those for THR and mean quality-adjusted life-years (QALYs) were lower. The incremental cost-effectiveness ratio for RS was dominated by THR, that is, THR was cheaper and more effective than RS (for a lifetime horizon in the base-case analysis, the incremental cost of RS was £11,284 and the incremental QALYs were -0.0879). For all age and sex groups RS remained clearly dominated by THR. Cost-effectiveness acceptability curves showed that, for all patients, THR was almost 100% cost-effective at any willingness-to-pay level. There were age and sex differences in the populations with different types of THR and variations in revision rates (from 1.6% to 3.5% at 9 years). For the base-case analysis, for all age and sex groups and a lifetime horizon, mean costs for category E (cemented components with a polyethylene-on-ceramic articulation) were slightly lower and mean QALYs for category E were slightly higher than those for all other THR categories in both deterministic and probabilistic analyses. Hence, category E dominated the other four categories. Sensitivity analysis using an age- and sex-adjusted log-normal model demonstrated that, over a lifetime horizon and at a willingness-to-pay threshold of £20,000 per QALY, categories A and E were equally likely (50%) to be cost-effective. LIMITATIONS A large proportion of the included studies were inconclusive because of poor reporting, missing data, inconsistent results and/or great uncertainty in the treatment effect estimates. This warrants cautious interpretation of the findings. The evidence on complications was scarce, which may be because of the absence or rarity of these events or because of under-reporting. The poor reporting meant that it was not possible to explore contextual factors that might have influenced study results and also reduced the applicability of the findings to routine clinical practice in the UK. The scope of the review was limited to evidence published in English in 2008 or later, which could be interpreted as a weakness; however, systematic reviews would provide summary evidence for studies published before 2008. CONCLUSIONS Compared with THR, revision rates for RS were higher, mean costs for RS were higher and mean QALYs gained were lower; RS was dominated by THR. Similar results were obtained in the deterministic and probabilistic analyses and for all age and sex groups THR was almost 100% cost-effective at any willingness-to-pay level. Revision rates for all types of THR were low. Category A THR (cemented components with a polyethylene-on-metal articulation) was more cost-effective for older age groups. However, across all age-sex groups combined, the mean cost for category E THR (cemented components with a polyethylene-on-ceramic articulation) was slightly lower and the mean QALYs gained were slightly higher. Category E therefore dominated the other four categories. Certain types of THR appeared to confer some benefit, including larger femoral head sizes, use of a cemented cup, use of a cross-linked polyethylene cup liner and a ceramic-on-ceramic as opposed to a metal-on-polyethylene articulation. Further RCTs with long-term follow-up are needed. STUDY REGISTRATION This study is registered as PROSPERO CRD42013003924. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Aileen Clarke
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Amy Grove
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Karoline Freeman
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Hema Mistry
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Martin Connock
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Rachel Court
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Matthew Costa
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Gaurav Suri
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - David Metcalfe
- Warwick Orthopaedics, University Hospitals Coventry and Warwickshire, Coventry, UK
| | - Michael Crowther
- Department of Health Sciences, University of Leicester, Leicester, UK
| | - Sarah Morrow
- Oxford Medical School, University of Oxford, Oxford, UK
| | - Samantha Johnson
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Paul Sutcliffe
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| |
Collapse
|
8
|
Meermans G, Goetheer-Smits I, Lim RF, Van Doorn WJ, Kats J. The difference between the radiographic and the operative angle of inclination of the acetabular component in total hip arthroplasty: use of a digital protractor and the circumference of the hip to improve orientation. Bone Joint J 2015; 97-B:603-10. [PMID: 25922452 DOI: 10.1302/0301-620x.97b5.34781] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A high radiographic inclination angle (RI) contributes to accelerated wear and has been associated with dislocation after total hip arthroplasty (THA). With freehand positioning of the acetabular component there is a lack of accuracy, with a trend towards a high radiographic inclination angle. The aim of this study was to investigate whether the use of a digital protractor to measure the operative inclination angle (OI) could improve the positioning of the acetabular component in relation to a 'safe zone'. We measured the radiographic inclination angles of 200 consecutive uncemented primary THAs. In the first 100 the component was introduced freehand and in the second 100 a digital protractor was used to measure the operative inclination angle. The mean difference between the operative and the radiographic inclination angles (∆RI-OI) in the second cohort was 12.3° (3.8° to 19.8°). There was a strong correlation between the circumference of the hip and ∆RI-OI. The number of RI outliers was significantly reduced in the protractor group (p = 0.002). Adjusting the OI, using a digital protractor and taking into account the circumference of the patient's hip, improves the RI significantly (p < 0.001) and does not require additional operating time.
Collapse
Affiliation(s)
- G Meermans
- Lievensberg Hospital, 4624 VT Bergen Op Zoom, The Netherlands
| | | | - R F Lim
- Lievensberg Hospital, 4624 VT Bergen Op Zoom, The Netherlands
| | - W J Van Doorn
- Lievensberg Hospital, 4624 VT Bergen Op Zoom, The Netherlands
| | - J Kats
- Lievensberg Hospital, 4624 VT Bergen Op Zoom, The Netherlands
| |
Collapse
|
9
|
Vendittoli PA, Ganapathi M, Roy AG, Lusignan D, Lavigne M. A comparison of clinical results of hip resurfacing arthroplasty and 28 mm metal on metal total hip arthroplasty: a randomised trial with 3-6 years follow-up. Hip Int 2010; 20:1-13. [PMID: 20235065 DOI: 10.1177/112070001002000101] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 11/13/2009] [Indexed: 02/04/2023]
Abstract
Two hundred and nine hips were randomised to receive either a 28 mm total hip athroplasty (THA, 100 hips) or hybrid hip resurfacing (HR, 109 hips). At 1 and 2 years post-operatively, patients with HR achieved statistically significantly better WOMAC functional scores. However, differences in scores were of slight clinical relevance with a difference of 2.2/100 and 3.3/100, at 1 and 2 years respectively (p=0.007). After an average follow-up of 56 months (range 36-72) there were similar re-operation rates 7/100 THA and 6/109 HR (p=0.655) and revision rates 2/100 THA and 4/109 HR (p=0.470). However, the types of complications were different. Higher early aseptic loosening rate was found in HR and long-term survival analysis of both patient cohorts is necessary to determine whether the potential bone preservation advantage offers by HR will overcome its earlier higher failure rate.
Collapse
Affiliation(s)
- Pascal-André Vendittoli
- Surgery Department, Maisonneuve Rosemont Hospital, University of Montreal, Montreal, Quebec, Canada.
| | | | | | | | | |
Collapse
|