1
|
Tsikandylakis G, Mortensen KRL, Gromov K, Mohaddes M, Malchau H, Troelsen A. The Use of Large Metal Heads in Thin Vitamin E-Doped Cross-Linked Polyethylene Inserts Does Not Increase Polyethylene Wear in Total Hip Arthroplasty: 5-Year Results From a Randomized Controlled Trial. J Arthroplasty 2024; 39:1804-1810. [PMID: 38350518 DOI: 10.1016/j.arth.2024.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 01/30/2024] [Accepted: 02/05/2024] [Indexed: 02/15/2024] Open
Abstract
BACKGROUND Vitamin E-doped cross-linked polyethylene (VEPE) has encouraged the use of larger heads in thinner liners in total hip arthroplasty (THA). However, there are concerns about wear and mechanical failure of the thin liner, especially when metal heads are used. The aim of this randomized controlled trial was to investigate if the use of a large metal head in thin VEPE liner would increase polyethylene wear compared with a standard 32-mm metal head and to compare periacetabular radiolucencies and patient-reported outcomes in THA. METHODS There were 96 candidates for uncemented THA who were randomly allocated to either the largest possible metal head (36 to 44 mm) that could be fitted in the thinnest available VEPE liner (intervention group) or a standard 32-mm metal head (control group). The primary outcome was proximal head penetration, measured with a model-based radiostereometric analysis. Secondary outcomes were periacetabular radiolucencies and patient-reported outcomes. The midterm results of the trial at 5 years are presented. RESULTS The median total proximal head penetration (interquartile range) was -0.04 mm (-0.12 to 0.02) in the intervention group and -0.03 mm (-0.14 to 0.05) in the control group (P = .691). The rates of periacetabular radiolucencies were 1 of 44 and 4 of 42 (P = .197), respectively. Patient-reported hip function and health-related quality of life did not differ between the groups, but participants in the intervention group reported a higher level of activity (median University of California Level of Activity score 7 versus 6, P = .020). There were 5 revisions caused by dislocations (2), periprosthetic fracture (1), stem subsidence (1), or iliopsoas impingement (1). CONCLUSIONS Large metal heads in thin VEPE liners did not increase liner wear and were not associated with liner failure 5 years after THA.
Collapse
Affiliation(s)
- Georgios Tsikandylakis
- Department of Orthopaedics, Region of Västra Götaland, Sahlgrenska University Hospital, Mölndal, Sweden; Institute of Clinical Sciences, Department of Orthopaedics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Kristian R L Mortensen
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark; Faculty of Health Sciences, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark; Faculty of Health Sciences, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Maziar Mohaddes
- Department of Orthopaedics, Region of Västra Götaland, Sahlgrenska University Hospital, Mölndal, Sweden; Institute of Clinical Sciences, Department of Orthopaedics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Henrik Malchau
- Department of Orthopaedics, Region of Västra Götaland, Sahlgrenska University Hospital, Mölndal, Sweden; Institute of Clinical Sciences, Department of Orthopaedics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Harvard University, Boston, Massachusetts
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark; Faculty of Health Sciences, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
2
|
Matsuoka T, Takahashi Y, Ishida T, Tateiwa T, Shishido T, Yamamoto K. In vivo creep and wear performance of vitamin-E-diffused highly crosslinked polyethylene in total hip arthroplasty. Arch Orthop Trauma Surg 2023; 143:7195-7203. [PMID: 37438580 DOI: 10.1007/s00402-023-04972-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Accepted: 06/26/2023] [Indexed: 07/14/2023]
Abstract
INTRODUCTION An acetabular liner thickness of around 6 mm remains the "gold standard" in total hip arthroplasty. Some surgeons have been recommending the use of the thickest possible liner because contact stress and strain in articulating surfaces decrease with increasing the wall thickness. The purpose of this study was to determine whether in vivo creep and wear performance could be enhanced using a thicker liner over the standard thickness in vitamin-E-diffused highly crosslinked polyethylene (HXLPE). MATERIALS AND METHODS One hundred and twenty-two hips were allocated to age-matched, sex-matched, and body mass index-matched two subgroups implanted either with a 6.8- or 8.9-mm-thick vitamin-E-diffused HXLPE liner against 28-mm cobalt-chrome femoral head, and followed-up for 7 years. Linear and volumetric penetration of femoral head into the liners attributed to creep and wear were analyzed for each group. RESULTS Compressive creep strain generated at the initial 6 months was significantly larger in the 6.8-mm group (2.6%) than in the 8.9-mm group (2.2%). The linear steady-state wear observed after 2 years was 0.0019 and 0.0015 mm/year, whereas the volumetric steady-state wear was 0.54 and 0.45 mm3/years in the 6.8- and 8.9-mm-thick groups, respectively. Although less strain in the thicker group resulted in a slightly less wear, it did not reach significant differences in the steady-state wear rates between the groups. CONCLUSION No clinical significance for using a thicker liner over the standard thickness (6.8 mm → 8.9 mm) was confirmed in the vitamin-E-diffused HXLPE according to the 7-year follow-up. The wear rates for both thicknesses were very low enough to prevent osteolysis, and no mechanical failure was observed at any follow-up interval. Nevertheless, since the significantly higher strain was seen in the thinner liner, further follow-up is needed to compare the longer term wear and the incidence of osteolysis and component fracture.
Collapse
Affiliation(s)
- Tsunehiro Matsuoka
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Yasuhito Takahashi
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
- Department of Bone and Joint Biomaterial Research, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
| | - Tsunehito Ishida
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Toshiyuki Tateiwa
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Takaaki Shishido
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Kengo Yamamoto
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| |
Collapse
|
3
|
El-Sahoury JAN, Kjærgaard K, Ovesen O, Hofbauer C, Overgaard S, Ding M. Vitamin E-diffused liners show less head penetration than cross-linked polyethylene liners in total hip arthroplasty: a ten-year multi-arm randomized trial. Bone Joint J 2023; 105-B:1052-1059. [PMID: 37777211 DOI: 10.1302/0301-620x.105b10.bjj-2023-0115.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/02/2023]
Abstract
Aims The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA). Methods A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size. Results A total of 116 patients participated, of whom 77 were male. The median ages of the vE-PE 32 mm and 36 mm groups were 65 (interquartile range (IQR) 57 to 67) and 63 years (IQR 56 to 66), respectively, and of the XLPE 32 mm and 36 mm groups were 64 (IQR 58 to 66) and 61 years (IQR 54 to 66), respectively. Mean total head penetration was significantly lower into vE-PE acetabular liner groups than into XLPE acetabular liner groups (-0.219 mm (95% confidence interval -0.348 to -0.090); p = 0.001). There were no differences in wear according to head size, acetabular component migration, or PROMs, except for UCLA. There were no cases of aseptic loosening or failures requiring revision at long-term follow-up. Conclusion Significantly lower wear was observed in vE-PE acetabular liners than in XLPE acetabular liners. No difference in wear was observed between different head size or PROMs except for the UCLA at ten years.
Collapse
Affiliation(s)
- Joseph A N El-Sahoury
- Department of Orthopaedic Surgery and Traumatology, and Department of Clinical Research, Orthopaedic Research Laboratory, Odense University Hospital, University of Southern Denmark, Odense, Denmark
| | - Kristian Kjærgaard
- Department of Orthopaedic Surgery and Traumatology, and Department of Clinical Research, Orthopaedic Research Laboratory, Odense University Hospital, University of Southern Denmark, Odense, Denmark
| | - Ole Ovesen
- Department of Orthopaedic Surgery and Traumatology, and Department of Clinical Research, Orthopaedic Research Laboratory, Odense University Hospital, University of Southern Denmark, Odense, Denmark
| | | | - Søren Overgaard
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Orthopaedic Surgery & Traumatology, Copenhagen University Hospital, Copenhagen, Denmark
| | - Ming Ding
- Department of Orthopaedic Surgery and Traumatology, and Department of Clinical Research, Orthopaedic Research Laboratory, Odense University Hospital, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
4
|
Jørgensen PB, Kaptein BL, Søballe K, Jakobsen SS, Stilling M. Five-year polyethylene cup migration and PE wear of the Anatomic Dual Mobility acetabular construct. Arch Orthop Trauma Surg 2023; 143:5957-5965. [PMID: 36802237 PMCID: PMC9942043 DOI: 10.1007/s00402-023-04774-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 01/07/2023] [Indexed: 02/23/2023]
Abstract
INTRODUCTION Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). MATERIALS AND METHODS A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. RESULTS Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI - 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. CONCLUSIONS Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.
Collapse
Affiliation(s)
- Peter Bo Jørgensen
- AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark.
| | - Bart L Kaptein
- Biomechanics and Imaging Group, Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Kjeld Søballe
- AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
| | - Stig S Jakobsen
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
| | - Maiken Stilling
- AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
| |
Collapse
|
5
|
Zheng C, Xu J, Wu L, Wu Y, Liu Y, Shen B. Comparisons of Different Bearing Surfaces in Cementless Total Hip Arthroplasty: A Systematic Review and Bayesian Network Analysis. J Arthroplasty 2023; 38:600-609. [PMID: 36265721 DOI: 10.1016/j.arth.2022.10.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 10/06/2022] [Accepted: 10/11/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND We aimed to make comparisons of different bearing surfaces in patients after cementless total hip arthroplasty. METHODS The network meta-analysis was guided by the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guideline. The primary outcomes were implant survival and Harris hip score (HHS). Secondary outcomes included linear wear rates and serum level of metal ions. Subgroup analyses were performed by: (1) classifying head sizes as small and large; (2) femoral heads as ceramic and metal; and (3) liners as metal, ceramic, polyethylene, highly cross-linked polyethylene (HXP), or vitamin E-infused highly cross-linked polyethylene (HXPE). A total of 64 eligible RCTs with different bearings were assessed. Overall inconsistency and heterogeneity were acceptable. RESULTS In the 10 years follow-up, metal-on-polythene and ceramic-on-polythene bearings with small heads showed higher risk for revisions compared with metal-on-HXP and ceramic-on-HXP bearings with small heads. Similarly, only metal or ceramic-on-polythene bearings with small heads showed inferiority in HHS compared with other bearings. Conventional polyethylene liners showed higher linear wear rates compared with HXP, HXPE, and ceramic liners at 5 and 10 years after surgery, while metal-on-metal and ceramic-on-metal bearings showed higher serum level of cobalt and chromium. CONCLUSION Bearings containing HXP, HXPE, and ceramic liners showed comparable survivorship and hip function at follow-up of 5 and 10 years. Hard-on-hard bearings containing metal had higher serum level of metal ions than others. Bearings containing conventional polyethylene had worse performance in terms of implant survival, hip function, and wear rates. LEVEL OF EVIDENCE Level I.
Collapse
Affiliation(s)
- Che Zheng
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Jiawen Xu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Liming Wu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Yuangang Wu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Yuan Liu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Bin Shen
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| |
Collapse
|
6
|
Spece H, Yarbrough RV, Kurtz SM. In Vivo Performance of Vitamin E Stabilized Polyethylene Implants for Total Hip Arthroplasty: A Review. J Arthroplasty 2022; 38:970-979. [PMID: 36481286 DOI: 10.1016/j.arth.2022.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/28/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Vitamin E stabilization was introduced to improve the oxidative stability, wear resistance, and mechanical properties of highly crosslinked polyethylene (HXLPE). In this literature review, we asked: (1) How has vitamin E-stabilized HXLPE (VEPE) performed in vivo for total hip arthroplasty (THA) and how does it compare with conventional ultra-high molecular weight polyethylene (UHMWPE) and HXLPE without vitamin E; and (2) Is there an apparent difference in the clinical performance of VEPE created by blending versus diffusion? METHODS We performed a systematic search of the literature according to the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines using PubMed and Embase. Included studies reported the in vivo behavior of VEPE in THA. We reviewed 41 studies. RESULTS For all studies that compared polyethylene with and without VE stabilization, outcomes for VEPE were either equivalent or superior to the control group (for HXLPE without VE and conventional UHMWPE controls, respectively). Hip insert wear rates were generally less than 0.1 mm/year and in most cases were less than 0.05 mm/year. No VEPE components were revised for osteolysis or adverse outcomes specific to VE incorporation. CONCLUSION Across the literature, we found that VEPE was reported to be clinically effective for THA applications, with much of the research indicating positive clinical outcomes and lower or equivalent wear rates compared to conventional UHMWPE and HXLPE controls without VE. Instances of early component fracture were reported, but have multiple potential causes. There is a gap in the literature for comparison of blended and diffused components, so the in vivo impact of VE incorporation method remains to be seen. Overall, this study provides a comprehensive summary of VEPE clinical performance for THA and may serve as a resource for future investigations.
Collapse
Affiliation(s)
- Hannah Spece
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA; Gyroid, LLC, Haddonfield, NJ
| | | | - Steven M Kurtz
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA; Gyroid, LLC, Haddonfield, NJ
| |
Collapse
|
7
|
Gromov K, Sillesen NH, Kallemose T, Husted H, Malchau H, Troelsen A. Safety of vitamin E-infused highwall liners for routine use in primary total hip arthroplasty: single centre, short-term follow-up of 1221 cases. Hip Int 2022; 32:56-61. [PMID: 33167730 DOI: 10.1177/1120700020969644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Introduction of new implants should be monitored closely to capture any signs of compromising patient safety. Vitamin E infused highly-crosslinked polyethylene liners (VEPE) offer the potential for reduced wear. Highwall liners have been hypothesised to result in increased wear and potential liner fractures. The aim of this study was to determine the 3-7-year follow-up of highwall VEPE for primary total hip arthroplasty (THA), focusing on liner-related complications. METHODS We included 1221 consecutive THA operations from July 2010 to May 2014 with minimum follow-up of 3 (3.1-6.8) years Data collected included demographics, implant data, complications, reoperations, and deaths. Data were cross-referenced with the Danish Hip Arthroplasty Registry in order to ensure validity and completeness. Acetabular shell position was measured using Martell Hip Analysis Suite in a subgroup of 931 THAs. RESULTS Cumulative stem revision and shell revision at 3-year follow-up was 3.4% and 0.4% respectively. There were no revisions due to liner failure. Reason for revision included 11 dislocations, 15 soft-tissue revisions for infection, 44 stem revisions of which 34 were periprosthetic fractures and 13 shell revisions of which 6 were combined shell and stem revisions. CONCLUSION Early follow-up of VEPE liners for primary THA have not shown any revisions associated with liner failure. Continued monitoring of new materials are necessary to capture any signs of compromised patient safety.
Collapse
Affiliation(s)
- Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark
| | - Nanna H Sillesen
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark
| | - Thomas Kallemose
- Clinical Research Centre, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark
| | - Henrik Husted
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark
| | - Henrik Malchau
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark.,Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark
| |
Collapse
|
8
|
Tsikandylakis G, Mortensen KRL, Gromov K, Mohaddes M, Malchau H, Troelsen A. Does the use of the largest possible metal head increase the wear of vitamin E-doped cross-linked polyethylene? Two-year results from a randomized controlled trial. Bone Joint J 2021; 103-B:1206-1214. [PMID: 34192938 DOI: 10.1302/0301-620x.103b7.bjj-2020-2064.r1] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty. METHODS In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes. RESULTS At two years, 44 patients in each group were available for RSA assessment. The median total two-year proximal head penetration was -0.02 mm (IQR -0.09 to 0.07; p = 0.548) for the largest possible head and -0.01 mm (IQR -0.07 to 0.10; p = 0.525) for 32 mm heads. Their difference was not statistically significant (p = 0.323). Neither group demonstrated a bedding-in period. The median steady-state volumetric wear rates were 6.1 mm3/year (IQR -59 to 57) and 3.5 mm3/year (-21 to 34) respectively, and did not differ between the groups (p = 0.848). There were no statistically significant differences in periacetabular radiolucencies or patient-reported outcomes. CONCLUSION The use of the largest possible metal head did not increase vitamin E-doped cross-linked polyethylene wear compared with 32 mm heads at two years. Linear wear was negligible and volumetric wear rates were very low in both head size groups. There was a tendency towards higher values of volumetric wear in large heads that warrants longer-term evaluation before any definite conclusions about the association between head size and wear can be drawn. Cite this article: Bone Joint J 2021;103-B(7):1206-1214.
Collapse
Affiliation(s)
- Georgios Tsikandylakis
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Orthopaedics, University of Gothenburg, Sahlgrenska Academy, Institute of Clinical Sciences, Gothenburg, Sweden
| | - Kristian R L Mortensen
- Department of Clinical Medicine, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Kirill Gromov
- Department of Clinical Medicine, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark.,Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Maziar Mohaddes
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Orthopaedics, University of Gothenburg, Sahlgrenska Academy, Institute of Clinical Sciences, Gothenburg, Sweden
| | - Henrik Malchau
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Orthopaedics, University of Gothenburg, Sahlgrenska Academy, Institute of Clinical Sciences, Gothenburg, Sweden.,Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts, USA.,Harvard Medical School, Harvard University, Boston, Massachusetts, USA
| | - Anders Troelsen
- Department of Clinical Medicine, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark.,Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| |
Collapse
|
9
|
Hemmilä M, Laaksonen I, Matilainen M, Eskelinen A, Haapakoski J, Puhto AP, Kettunen J, Pamilo K, Mäkelä KT. Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register. Acta Orthop 2021; 92:316-322. [PMID: 33517823 PMCID: PMC8231410 DOI: 10.1080/17453674.2021.1879513] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The use of crosslinked polyethylene in total hip arthroplasty (THA) has decreased wear remarkably. It has been suggested that the antioxidative effects of vitamin E may enhance the wear properties of polyethylene even further. This study evaluates revision rates between vitamin E-infused polyethylene liners (E1 and E-poly, ZimmerBiomet, Warsaw, IN, USA) versus moderately crosslinked polyethylene (ModXLPE) liners from the same manufacturer used in primary THA.Patients and methods - We conducted a study based on data from the Finnish Arthroplasty Register. The study group consisted of 2,723 THAs with a vitamin E-infused liner and a reference group of 2,707 THAs with a moderately crosslinked polyethylene liner. Survivorship, revision risk, and re-revision causes were compared between groups.Results - The 7-year survival of the vitamin E-infused polyethylene liner group and of the reference group with revision for any reason as the endpoint was comparable (94% [95% CI 92.9-94.9] and 93% [CI 91.9-93.9], respectively). The adjusted hazard ratio (HR) for any revision was similar between the groups (0.7 [CI 0.4-1.1]). When revision for aseptic loosening was studied as the endpoint, the survival for the study group was 99% (CI 98.6-99.4) and for the reference group 99% (CI 98.7-99.5), and the risk of revision was comparable between the study groups (HR 1.3 [CI 0.7-2.5]).Interpretation - After an observation period of 7 years vitamin E-infused liners shows results equal to results obtained with crosslinked polyethylene liners.
Collapse
Affiliation(s)
- Matias Hemmilä
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku; ,Correspondence:
| | - Inari Laaksonen
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku;
| | - Markus Matilainen
- Turku PET Centre, University of Turku and Turku University Hospital, Turku;
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement and Faculty of Medicine and Health Technologies, Tampere University, Tampere;
| | | | - Ari-Pekka Puhto
- Division of Operative Care, Department of Orthopaedic and Trauma Surgery, Oulu University Hospital, Oulu;
| | - Jukka Kettunen
- Department of Orthopaedics and Traumatology, Kuopio University Hospital, Kuopio, Finland
| | - Konsta Pamilo
- Coxa Hospital for Joint Replacement and Faculty of Medicine and Health Technologies, Tampere University, Tampere;
| | - Keijo T Mäkelä
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku;
| |
Collapse
|
10
|
Parekh A, Sood A, Monsef JB, Hamouda M, Hussain A, Gonzalez M. Second-Generation Highly Cross-Linked Polyethylene in Total Hip Arthroplasty. JBJS Rev 2021; 9:e20.00065. [PMID: 33982980 DOI: 10.2106/jbjs.rvw.20.00065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Amit Parekh
- Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois
| | - Anshum Sood
- Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois
| | - Jad Bou Monsef
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Awais Hussain
- Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois
| | - Mark Gonzalez
- Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois
| |
Collapse
|
11
|
Thoen PS, Nordsletten L, Pripp AH, Röhrl SM. Results of a randomized controlled trial with five-year radiostereometric analysis results of vitamin E-infused highly crosslinked versus moderately crosslinked polyethylene in reverse total hip arthroplasty. Bone Joint J 2020; 102-B:1646-1653. [DOI: 10.1302/0301-620x.102b12.bjj-2020-0721.r1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Aims Vitamin E-infused highly crosslinked polyethylene (VEPE) has been introduced into total hip arthroplasty (THA) with the aim of further improving the wear characteristics of moderately and highly crosslinked polyethylenes (ModXLPE and HXLPE). There are few studies analyzing the outcomes of vitamin E-infused components in cemented arthroplasty, though early acetabular component migration has been reported. The aim of this study was to measure five-year polyethylene wear and acetabular component stability of a cemented VEPE acetabular component compared with a ModXLPE cemented acetabular component. Methods In a prospective randomized controlled trial (RCT), we assessed polyethylene wear and acetabular component stability (primary outcome) with radiostereometric analysis (RSA) in 68 patients with reverse hybrid THA at five years follow-up. Patients were randomized to either a VEPE or a ModXLPE cemented acetabular component. Results Mean polyethylene wear in the proximal direction was 0.17 mm (SD 0.15) for the VEPE group and 0.20 mm (SD 0.09) for the ModXLPE group (p = 0.005) at five years. Annual proximal wear rates were 0.03 mm/year (VEPE) and 0.04 mm/year (ModXLPE). Total 3D wear was 0.21 mm (SD 0.26) and 0.23 mm (SD 0.10) for the VEPE and ModXLPE groups, respectively (p = 0.009). Total 3D cup translation was 0.72 mm (SD 0.70) (VEPE) and 0.50 mm (SD 0.44) (ModXLPE) (p = 0.409). Conclusion At five years, there was less polyethylene wear in the VEPE group than in the ModXLPE group. Both VEPE and ModXLPE cemented components showed low annual wear rates. Component stability was similar in the two groups and remained constant up to five years. Whether these results will equate to a lower long-term revision rate is still unknown. Cite this article: Bone Joint J 2020;102-B(12):1646–1653.
Collapse
Affiliation(s)
- Peder S. Thoen
- Division of Orthopedic Surgery, Oslo University Hospital Ullevål, Oslo, Norway
- Department of Surgery, Vestfold Hospital Trust, Tønsberg, Norway
- Institute for Clinical Medicine, University of Oslo, Oslo, Norway
| | - Lars Nordsletten
- Division of Orthopedic Surgery, Oslo University Hospital Ullevål, Oslo, Norway
- Institute for Clinical Medicine, University of Oslo, Oslo, Norway
| | - Are H. Pripp
- Department of Biostatistics, Oslo University Hospital Ullevål, Oslo, Norway
| | - Stephan M. Röhrl
- Division of Orthopedic Surgery, Oslo University Hospital Ullevål, Oslo, Norway
| |
Collapse
|
12
|
Kjærgaard K, Ding M, Jensen C, Bragdon C, Malchau H, Andreasen CM, Ovesen O, Hofbauer C, Overgaard S. Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial. Bone Joint J 2020; 102-B:1303-1310. [PMID: 32993343 PMCID: PMC7517722 DOI: 10.1302/0301-620x.102b10.bjj-2020-0138.r1] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Aims The most frequent indication for revision surgery in total hip arthroplasty (THA) is aseptic loosening. Aseptic loosening is associated with polyethylene liner wear, and wear may be reduced by using vitamin E-doped liners. The primary objective of this study was to compare proximal femoral head penetration into the liner between a) two cross-linked polyethylene (XLPE) liners (vitamin E-doped (vE-PE)) versus standard XLPE liners, and b) two modular femoral head diameters (32 mm and 36 mm). Methods Patients scheduled for a THA were randomized to receive a vE-PE or XLPE liner with a 32 mm or 36 mm metal head (four intervention groups in a 2 × 2 factorial design). Head penetration and acetabular component migration were measured using radiostereometric analysis at baseline, three, 12, 24, and 60 months postoperatively. The Harris Hip Score, University of California, Los Angeles (UCLA) Activity Score, EuroQol five-dimension questionnaire (EQ-5D), and 36-Item Short-Form Health Survey questionnaire (SF-36) were assessed at baseline, three, 12, 36, and 60 months. Results Of 220 screened patients, 127 were included in this study. In all, 116 received the allocated intervention, and 94 had their results analyzed at five years. Head penetration was similar between liner materials and head sizes at five years, vE-PE versus XLPE was -0.084 mm (95% confidence interval (CI) -0.173 to 0.005; p = 0.064), and 32 mm versus 36 mm was -0.020 mm (95% CI -0.110 to 0.071; p = 0.671), respectively. No differences were found in acetabular component migration or in the patient-reported outcome measures. Conclusion No significant difference in head penetration was found at five years between vE-PE and XLPE liners, nor between 32 mm and 36 mm heads. Cite this article: Bone Joint J 2020;102-B(10):1303–1310.
Collapse
Affiliation(s)
- Kristian Kjærgaard
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Ming Ding
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Carsten Jensen
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark.,Department of Orthopaedic Surgery, Kolding Hospital, Kolding, Denmark
| | - Charles Bragdon
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Christina M Andreasen
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Ole Ovesen
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
| | | | - Søren Overgaard
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
13
|
Langlois J, Hamadouche M. Recent update on crosslinked polyethylene in total hip arthroplasty. SICOT J 2020; 6:13. [PMID: 32412408 PMCID: PMC7227368 DOI: 10.1051/sicotj/2020013] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 04/23/2020] [Indexed: 02/02/2023] Open
Abstract
More than two decades after their clinical introduction, crosslinked polyethylenes (XLPE) have been widely adopted. Though concerns were initially raised regarding oxidation and brittleness, on a large scale, the first generation of XLPE continues to be highly effective 15 years after the surgery, even in a young and active population. Remelted XLPE might display lower wear rates than annealed XLPE. Second generation XLPEs, not only including sequentially irradiated and annealed but also associated with antioxidants, demonstrate encouraging short- to mid-term results. Registry data support clinical trial reports. Even in less favorable settings (lipped liners, dual mobility cups, revision surgery, hip resurfacing) results are promising. However, failures (fractures) have already been described. Therefore, a high level of surveillance remains crucial.
Collapse
Affiliation(s)
- Jean Langlois
-
Centre Orthopédique Santy 24, avenue Paul Santy 69008 Lyon France
-
Hôpital Privé Jean-Mermoz 55, avenue Jean-Mermoz 69008 Lyon France
| | - Moussa Hamadouche
-
Département de Chirurgie Orthopédique, Université Paris-Descartes, Assistance Publique-Hôpitaux de Paris, Hôpital Cochin 27, rue du Faubourg Saint-Jacques 75014 Paris France
| |
Collapse
|