1
|
Ko YS, Kang SY, Kim HS, Yoo JJ. Computed Tomography Evaluation of Alumina Ceramic-on-Ceramic Total Hip Arthroplasty With More Than 20 years of Follow-Up: Is a Follow-Up Computed Tomography Scan Necessary? J Arthroplasty 2025; 40:144-151. [PMID: 38944063 DOI: 10.1016/j.arth.2024.06.058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 06/20/2024] [Accepted: 06/24/2024] [Indexed: 07/01/2024] Open
Abstract
BACKGROUND Ceramic-on-ceramic (CoC) bearings have been increasingly used in total hip arthroplasty (THA) because of their superior wear resistance and biocompatibility. However, there is a scarcity of reports on the computed tomography (CT) evaluation of CoC bearings with more than 10 years. The aim of this study was to evaluate the long-term CT results of THA using CoC bearings for more than 20 years of follow-up. We hypothesized that there would be no wear, osteolysis, or ceramic fracture. METHODS Between November 1997 and June 2003, 956 hips underwent THA using alumina-on-alumina bearings at a tertiary referral hospital. Among them, 107 hips were assessed, all of which underwent a CT examination more than 20 years after the index surgery. The mean age at the time of surgery was 41 years, and a CT scan was performed at an average of 22.0 years postoperatively (range, 20.0 to 25.1). The CT scans were thoroughly assessed for osteolysis, stem notching, and ceramic component fracture. RESULTS No loosening was observed in the acetabular cup or femoral stem. Stem notching was observed in 3 hips (2.8%). In the CT scan taken after a minimum of 20 years of follow-up, 1 case (0.9%) of osteolysis around the cup and 2 cases (1.9%) of osteolysis around the femoral stem were noted. Suspected chip fractures of the ceramic insert were discovered in 4 cases (3.7%). Despite these findings, the patients remained asymptomatic, and no subsequent surgical intervention was needed after close follow-up. CONCLUSIONS Routine CT examinations for patients who underwent THA using CoC bearings over 20 years ago revealed unexpected findings, such as osteolysis and suspected chip fractures of the ceramic liner. However, routine CT scans may not be universally necessary. The CT evaluation in this cohort should be selectively performed for patients who have relevant clinical symptoms. LEVEL OF EVIDENCE Level III, Therapeutic study.
Collapse
Affiliation(s)
- Young-Seung Ko
- Department of Orthopedic Surgery, Seoul National University Hospital, College of Medicine, Seoul National University, Seoul, South Korea; Department of Orthopaedic Surgery, Hallym university Dong-Tan Sacred Heart Hospital, Hwaseong, South Korea
| | - Sang Yoon Kang
- Department of Orthopedic Surgery, Seoul National University Hospital, College of Medicine, Seoul National University, Seoul, South Korea
| | - Hong Seok Kim
- Department of Orthopedic Surgery, Seoul National University Hospital, College of Medicine, Seoul National University, Seoul, South Korea
| | - Jeong Joon Yoo
- Department of Orthopedic Surgery, Seoul National University Hospital, College of Medicine, Seoul National University, Seoul, South Korea
| |
Collapse
|
2
|
Kim HS, Park JW, Ha JH, Lee YK, Ha YC, Koo KH. Third-Generation Ceramic-on-Ceramic Total Hip Arthroplasty in Patients with Osteonecrosis of the Femoral Head: A 10- to 16-year Follow-up Study. J Bone Joint Surg Am 2022; 104:68-75. [PMID: 34780390 DOI: 10.2106/jbjs.20.00720] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Long-term follow-up results of ceramic-on-ceramic (COC) total hip arthroplasty (THA), specifically, in patients with osteonecrosis of the femoral head (ONFH) are unknown. We evaluated (1) clinical results and radiological outcomes, (2) ceramic-related complications: noise and ceramic fracture, (3) osteolysis, and (4) survivorship after alumina COC THA in ONFH patients with longer than 10-year follow-up. METHODS From May 2003 to June 2009, 325 ONFH patients (403 hips) underwent primary THAs at our department. Among them, 231 patients (293 THAs) were followed for 10 to 16 (mean, 12.9) years. There were 148 men and 83 women, their mean age at the time of THA was 47.2 years, and their mean body index was 24.0 kg/m2. The postoperative CT scans were done in 160 hips. RESULTS Grinding sensation or squeak was noted in 6.8% (20/293), ceramic head fracture occurred in 2.4% (7/293) and acetabular osteolysis developed in 0.7% (2/293). All 7 ceramic fractures occurred in 28-mm short-neck heads. There was no detectable wear or prosthetic loosening, and the 16-year survivorship was 96.0% (95% confidence interval; 93.8% to 98.2%). The mean Harris hip score was 91.7 (range, 84 to 100) points at the final follow-up. CONCLUSIONS The 10- to 16-year results of alumina COC THAs were encouraging with an excellent survivorship. However, ceramic fracture and noise still remain matters of concern. We recommend not to use 28-mm short-neck ceramic head to avoid ceramic head fractures. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Hong Seok Kim
- Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jung Wee Park
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Joo Hyung Ha
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.,Department of Orthopedic Surgery, Seoul National University College of Medicine, 166 Gumi-ro, Bundang-gu, Seongnam-si, 463-707, Republic of Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, Republic of Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.,Department of Orthopedic Surgery, Seoul National University College of Medicine, 166 Gumi-ro, Bundang-gu, Seongnam-si, 463-707, Republic of Korea
| |
Collapse
|
3
|
Schopper C, Luger M, Hipmair G, Schauer B, Gotterbarm T, Klasan A. The race for the classification of proximal periprosthetic femoral fractures : Vancouver vs Unified Classification System (UCS) - a systematic review. BMC Musculoskelet Disord 2022; 23:280. [PMID: 35321671 PMCID: PMC8944079 DOI: 10.1186/s12891-022-05240-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Accepted: 03/16/2022] [Indexed: 11/10/2022] Open
Abstract
Background Periprosthetic femoral fractures (PFFs) represent a major cause for surgical revision after hip arthroplasty with detrimental consequences for patients. The Vancouver classification has been traditionally used since its introduction in 1995. The Unified Classification System (UCS) was described in 2014, to widen the spectrum by aiming for a more comprehensive approach. The UCS also aimed to replace the Vancouver classification by expanding the idea of the Vancouver classification to the whole musculoskeletal apparatus. After introduction of the UCS, the question was raised, whether the UCS found its place in the field of analysing PFFs. Therefore, this systematic review was performed to investigate, the use of the UCS compared to the established Vancouver classification. Methods Medline was searched for reports published between 1 January 2016 and 31 November 2020, without language restriction. Included were original articles, irrespective of the level of evidence and case reports reporting on a PFF and using either the Vancouver or the UCS to classify the fractures. Excluded were reviews and systematic reviews. Results One hundred forty-six studies were included in the analysis. UCS has not been used in a single registry study, giving a pooled cohort size of 3299 patients, compared to 59,178 patients in studies using the Vancouver classification. Since 2016, one study using UCS was published in a top journal, compared to 37 studies using the Vancouver classification (p=0.29). During the study period, the number of yearly publications remained stagnant (p=0.899). Conclusions Despite valuable improvement and expansion of the latter UCS, to date, the Vancouver system clearly leads the field of classifying PFFs in the sense of the common use. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-022-05240-w.
Collapse
Affiliation(s)
- Clemens Schopper
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstrasse 9, 4020 Linz and Altenberger Strasse 69, 4040, Linz, Austria
| | - Matthias Luger
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstrasse 9, 4020 Linz and Altenberger Strasse 69, 4040, Linz, Austria.
| | - Günter Hipmair
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstrasse 9, 4020 Linz and Altenberger Strasse 69, 4040, Linz, Austria
| | - Bernhard Schauer
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstrasse 9, 4020 Linz and Altenberger Strasse 69, 4040, Linz, Austria
| | - Tobias Gotterbarm
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstrasse 9, 4020 Linz and Altenberger Strasse 69, 4040, Linz, Austria
| | - Antonio Klasan
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstrasse 9, 4020 Linz and Altenberger Strasse 69, 4040, Linz, Austria
| |
Collapse
|
4
|
Logroscino G, Saracco M, Maccauro G, Urbani A, Ciavardelli D, Consalvo A, Ferraro D, Falez F. Ceramic-on-metal coupling in THA: long term clinical and radiographic outcomes using two different short stems. BMC Musculoskelet Disord 2022; 22:1065. [PMID: 35193540 PMCID: PMC8864779 DOI: 10.1186/s12891-022-05077-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 01/31/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Hip prosthetic replacement surgery is the gold standard for patients affected by symptomatic osteoarthritis. The ceramic-on-metal hybrid hard-on-hard bearing was initially launched on the market with the purpose of reducing adhesive and corrosion wear, loss of metal debris and ions and risk of fracture and squeaking. However, this bearing was withdrawn from the market, in the apprehension of local and systemic toxicity. The aim of this study is to evaluate the reliability and safety of ceramic-on-metal bearing at long term follow-up. METHODS From 2 cohorts of patients suffering of hip osteoarthritis who underwent total hip arthroplasty using ceramic-on-metal bearing with two different short stems, 19 of the GROUP A and 25 of the GROUP B were suitable for this study. All patients were compared clinically using the Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), visual analogue scale (VAS), 12-item Short Form Health Survey (SF12P/M), and radiographically. Blood samples were collected in order to evaluate chromium and cobalt ions level. The two groups were compared in terms of metal ions blood levels, and finally all the implanted prostheses were compared with a healthy control group. RESULTS All the implanted stems were well-positioned and osseointegrated at a mean follow-up of 114 months. Improvements were observed for all clinical scores comparing preoperative and postoperative values in both groups. Radiographic evaluation showed a good ability to restore proper articular geometry. Chromium and cobalt ion analysis revealed values below the safety threshold except for 1 case in GROUP A (cup malposition) and 2 cases in GROUP B (6.1%). No revision occurred. CONCLUSIONS Ceramic-on-metal bearing is safe and reliable at long term follow-up in association to short stems arthroplasty, if the implant is correctly positioned. Chromium and cobalt metal ions blood levels evaluation should be performed annually.
Collapse
Affiliation(s)
- Giandomenico Logroscino
- Mininvasive and Computer-Assisted Orthopaedic Surgery, Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| | - Michela Saracco
- Department of Orthopaedics, Catholic University of Rome-Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo F. Vito,1, 00168, Rome, Italy.
| | - Giulio Maccauro
- Department of Orthopaedics, Catholic University of Rome-Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo F. Vito,1, 00168, Rome, Italy
| | - Andrea Urbani
- Institute of Biochemistry and Clinical Biochemistry, Catholic University of Rome-Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Domenico Ciavardelli
- School of Medicine and Surgery, University "Kore" of Enna, Enna, Italy
- Center for Advanced Studies and Technology (C.A.S.T.), University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Ada Consalvo
- Center for Advanced Studies and Technology (C.A.S.T.), University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Daniele Ferraro
- Department of Orthopaedics and Traumatology, ASL Roma 1, S. Filippo Neri Hospital and S. Spirito Hospital, Rome, Italy
| | - Francesco Falez
- Department of Orthopaedics and Traumatology, ASL Roma 1, S. Filippo Neri Hospital and S. Spirito Hospital, Rome, Italy
| |
Collapse
|
5
|
Hallan G, Fenstad AM, Furnes O. What Is the Frequency of Fracture of Ceramic Components in THA? Results from the Norwegian Arthroplasty Register from 1997 to 2017. Clin Orthop Relat Res 2020; 478:1254-1261. [PMID: 32348085 PMCID: PMC7319382 DOI: 10.1097/corr.0000000000001272] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Accepted: 03/31/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Ceramic bearings in THA have been used to reduce wear and, more recently, to avoid metals in the bearing because of the risk of metal ions adverse effects. Potential disadvantages to ceramic bearings are their brittleness and the ceramic fracture risk, which may lead to revision surgery. The frequency of revision for a fracture ceramic bearing, however, has not been thoroughly studied. QUESTIONS/PURPOSES (1) What is the frequency of revision for a fractured ceramic bearing in ceramic-on-polyethylene (CoP) and ceramic-on-ceramic (CoC) THAs, and is there any difference between alumina ceramics and alumina matrix composites (AMC)? (2) What are the factors associated with this complication? (3) To what extent did the patients who underwent revision for a fractured ceramic bearing undergo subsequent revisions, and for what reason? METHODS The Norwegian Arthroplasty Register has collected data on hip arthroplasty since 1987 and has a completeness of reporting of 97.3% for primary THAs and 93.3% for revision. From 1997 to 2017, 146,171 primary THAs were registered in the Norwegian Arthroplasty Register. Of these, 31,479 had a CoP articulation and 5790 had a CoC articulation. Two manufacturers produced ceramic heads; one produced 25,678 alumina heads and the other made 2465 alumina heads. All 7901 AMC heads were made by the same manufacturer. Patients who underwent CoP THA were a median (range) of 63 years old (11 to 98) and CoC THA were a median (range) 61 years old (17 to 95); 38% (11,833 of 31,479) of the patients who underwent CoP THA and 41% (2379 of 5790) of the patients who underwent CoC THA were males. Femoral heads made of alumina (n = 28,143), zirconia (n = 1225), and AMC (n = 7901) ceramics were used. To assess revision frequency, we identified patients who underwent revision because of fracture of a ceramic head and/or liner, and calculated the Kaplan-Meier survivorship free of revision for fracture in CoC and CoP articulations. Alumina ceramics and AMC were compared. In terms of factors potentially associated with revision, patient factors (age, sex, and diagnosis), type of articulation (CoP or CoC), femoral head size, and femoral head/neck length were evaluated with Cox regression models to evaluate any association with ceramic fracture and a Poisson regression to compare alumina and AMC head fractures. To evaluate subsequent revisions, hips that were revised for ceramic fracture were evaluated for any further revisions; Kaplan-Meier survivorship free of further revisions was calculated, and revision causes were identified. RESULTS Survivorship free from revision for ceramic fracture was 99.9% (95% CI 99.9 to 99.9) for CoP bearings, and 99.8% (95% CI 99.6 to 100) for CoC bearings at 10 years, with 7467 and 1884 hips at risk in the two groups, respectively. The hazard ratio for ceramic head fracture was 3.6 (95% CI 1.7 to 7.6) for CoC compared with CoP. The risk of fracture was greater for alumina ceramics than for AMC heads (adjusted HR 14.1 [95% CI 4.2 to 47.0]; p < 0.001). Factors that were associated with revision for fracture of a ceramic head were male sex (HR 5.2 [95% CI 2.6 to 10.4]; p < 0.001), a CoC articulation compared with CoP (HR 3.6 [95% CI 1.7 to 7.6]; p = 0.001), a 28-mm femoral head compared with a 32-mm head (HR 2.7 [95% CI 1.1 to 6.4]; p = 0.02), and short head/neck length compared with a medium head/neck length (HR 2.5 [95% CI 1.1 to 5.3]; p = 0.03). Five of 50 patients undergoing revision for ceramic fracture underwent further revisions, resulting in a 5-year survivorship free from re-revision of 86% (95% CI 74.4 to 98.0). The reasons for re-revision were infection (n = 2), another ceramic head fracture (n = 2), and cup loosening (n = 1). CONCLUSIONS Fracture of a ceramic THA bearing is rare and seems to affect about one in 1000 patients who receive such a bearing. To minimize the risk of this complication, surgeons should avoid small femoral heads (< 32 mm) and the shortest head/neck lengths. Surgeons should also know that the risk is increased in CoC articulations and in males. Bearings made of AMC appear to be at lower risk than those made from alumina ceramics. However, the long-term clinical wear performance of AMC bearings has not been extensively studied and should be studied further. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Geir Hallan
- G. Hallan, A. M. Fenstad, O. Furnes, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway
- G. Hallan, O. Furnes, Department of Clinical Medicine, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Anne Marie Fenstad
- G. Hallan, A. M. Fenstad, O. Furnes, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Ove Furnes
- G. Hallan, A. M. Fenstad, O. Furnes, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway
- G. Hallan, O. Furnes, Department of Clinical Medicine, Faculty of Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
6
|
Kanzaki N, Chinzei N, Yamamoto T, Yamashita T, Ibaraki K, Kuroda R. Clinical Outcomes of Total Ankle Arthroplasty With Total Talar Prosthesis. Foot Ankle Int 2019; 40:948-954. [PMID: 31056931 DOI: 10.1177/1071100719847135] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Total ankle arthroplasty (TAA) has been developed to treat patients with end-stage ankle osteoarthritis (OA). However, there is often difficulty in treating complicated pathologies such as ankle OA with subtalar joint OA and severe talar collapse. Therefore, this study aimed to explore the short-term results and complications of TAA with total talar prosthesis, known as combined TAA, as the new techniques to treat such complicated pathology. METHODS We examined postoperative results including ankle range of motion, Japanese Society for Surgery of the Foot (JSSF) scale, and complications. There were 22 patients (15 women), with mean follow-up of 34.9 (range, 24-53 months), and the mean age was 72 (range, 62-80) years. The main indications for combined TAA included osteoarthritis (18 patients), rheumatoid arthritis (3 patients), and talar osteonecrosis with osteoarthritis (one patient). RESULTS The mean range of motion improved from 4.0 to 14.4 degrees in dorsiflexion and from 23.8 to 32.0 degrees in plantarflexion. The JSSF scale improved from 50.5 to 91.5 points. Prolonged wound healing occurred in 3 patients, and medial malleolus fracture occurred in 4 patients. CONCLUSION Combined TAA was a reliable procedure for the treatment of not only ankle OA following avascular necrosis of talus but also of degeneration of both ankle and subtalar joints. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
- Noriyuki Kanzaki
- 1 Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Nobuaki Chinzei
- 1 Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan.,2 Department of Orthopaedic Surgery, Konan Hospital, Kobe, Japan
| | - Tetsuya Yamamoto
- 1 Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Takahiro Yamashita
- 1 Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Kazuyuki Ibaraki
- 1 Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Ryosuke Kuroda
- 1 Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| |
Collapse
|