1
|
Chen X, Li S, Wang Y, Liu X, Zhang Y, Qiu G, Qian W. Artificially Intelligent Three-Dimensionally-Printed Patient-Specific Instrument Improves Total Hip Arthroplasty Accuracy. J Arthroplasty 2023; 38:2060-2067.e1. [PMID: 36535443 DOI: 10.1016/j.arth.2022.12.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 12/03/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Patient-specific instrumentation (PSI) has the potential to improve the accuracy of implant positioning in total hip arthroplasty (THA). This prospective clinical study aimed to develop artificial intelligence to increase PSI production efficiency and assess accuracy, clinical outcomes, and learning curves. METHODS A convolutional neural network was applied to automatically process computer tomography images. PSI size and position were designed to guide the acetabular preparation and femoral neck resection. Thirty patients who underwent PSI-assisted THAs were matched to thirty patients who underwent free-hand THAs, and the component positions, as well as radiographic and clinical outcomes were analyzed. RESULTS PSI-assisted THA was significantly more accurate than free-hand THA at achieving the target component position. The mean absolute errors of cup inclination (P = .004) and anteversion (P < .001) were significantly smaller in the PSI group with fewer outliers. Calcar length (P = .002) and neck length (P = .026) were also more accurate in the PSI group. The leg length discrepancy was significantly lower in the PSI group (P = .002). There were no significant differences in operation time, blood loss, leg length discrepancy, or cup position among the first, second, and last 10 cases. CONCLUSION PSI-assisted THA offered more accurate component positions and better radiographic outcomes than free-hand THA. There was no evidence of a learning curve. Our findings suggest that PSI is a convenient and practical option to help surgeons achieve accurate surgical outcomes.
Collapse
Affiliation(s)
- Xi Chen
- Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China; Department of Orthopedic Surgery, West China Hospital, Sichuan, China; Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| | - Songlin Li
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| | - Yiou Wang
- Plastic Surgery Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| | - Xingyu Liu
- School of Life Sciences, Tsinghua University, Beijing, China; Institute of Biomedical and Health Engineering (iBHE), Tsinghua Shenzhen International Graduate School, Shenzhen, China; Department of Biomedical Engineering, School of Medicine, Tsinghua Univsersity, Beijing, China; Longwood Valley Medical Technology Co Ltd, Beijing, China
| | - Yiling Zhang
- Longwood Valley Medical Technology Co Ltd, Beijing, China
| | - Guixing Qiu
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| | - Wenwei Qian
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| |
Collapse
|
2
|
Zheng W, Liu X, Mei R, Deng G, Li Z, Lin R, Xiong S, Wu B. Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty. Biomed Eng Online 2023; 22:90. [PMID: 37705017 PMCID: PMC10500796 DOI: 10.1186/s12938-023-01152-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 08/31/2023] [Indexed: 09/15/2023] Open
Abstract
BACKGROUND The aim of this study was to evaluate the precision and feasibility of patient-specific instruments (PSI) in total hip arthroplasty (THA) as compared to the traditional free-hand (FRH) approach. METHODS During the period of January 1, 2021 to December 31, 2022, a randomized allocation was used for patients receiving unilateral primary THA to either the PSI or conventional operation group. The placement and size of the PSI were specifically chosen to guide femoral neck resection and prosthesis implantation. The study analyzed component positions and evaluated radiographic and clinical outcomes in 30 patients who received PSI-assisted THAs and 30 patients who received FRH THAs. This study was registered at China Clinical Trial Registry (number: ChiCTR2300072325) on June 9th, 2023. RESULTS The use of PSI in THA resulted in significantly higher precision in achieving the desired component position as compared to the FRH approach. The PSI group showed significantly smaller absolute errors of femoral anteversion (p < 0.001). No significant differences were found in operation time, intra-operative blood loss, hospitalization duration, or time to walk after surgery. CONCLUSION In conclusion, the application of patient-specific instruments in THA provides a simple and reliable solution to enhance the precision of femoral prosthesis placement with high accuracy and feasibility. This study highlights the potential benefits of using the PSI in THA.
Collapse
Affiliation(s)
- Wei Zheng
- Department of Orthopaedics, The Fourth Affiliated Hospital, Nanchang University, Nanchang, 330003, China
| | - Xuefeng Liu
- Department of Orthopaedics, The Fourth Affiliated Hospital, Nanchang University, Nanchang, 330003, China
| | - Runhong Mei
- Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital, Nanchang University, Nanchang, 330006, China
| | - Gaorong Deng
- Department of Orthopaedics, The Fourth Affiliated Hospital, Nanchang University, Nanchang, 330003, China
| | - Zhipeng Li
- Department of Orthopaedics, The Fourth Affiliated Hospital, Nanchang University, Nanchang, 330003, China
| | - Rongji Lin
- Department of Orthopaedics, The Fourth Affiliated Hospital, Nanchang University, Nanchang, 330003, China
| | - Shui Xiong
- Department of Orthopaedics, The Fourth Affiliated Hospital, Nanchang University, Nanchang, 330003, China
| | - Binghua Wu
- Department of Orthopaedics, The Fourth Affiliated Hospital, Nanchang University, Nanchang, 330003, China.
| |
Collapse
|
3
|
Buchalter DB, Gall AM, Buckland AJ, Schwarzkopf R, Meftah M, Hepinstall MS. Creating Consensus in the Definition of Spinopelvic Mobility. J Am Acad Orthop Surg Glob Res Rev 2023; 7:01979360-202306000-00005. [PMID: 37294841 PMCID: PMC10256344 DOI: 10.5435/jaaosglobal-d-22-00290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 03/29/2023] [Indexed: 06/11/2023]
Abstract
INTRODUCTION The term "spinopelvic mobility" is most often applied to motion within the spinopelvic segment. It has also been used to describe changes in pelvic tilt between various functional positions, which is influenced by motion at the hip, knee, ankle and spinopelvic segment. In the interest of establishing a consistent language for spinopelvic mobility, we sought to clarify and simplify its definition to create consensus, improve communication, and increase consistency with research into the hip-spine relationship. METHODS A literature search was performed using the Medline (PubMed) library to identify all existing articles pertaining to spinopelvic mobility. We reported on the varying definitions of spinopelvic mobility including how different radiographic imaging techniques are used to define mobility. RESULTS The search term "spinopelvic mobility" returned a total of 72 articles. The frequency and context for the varying definitions of mobility were reported. 41 papers used standing and upright relaxed-seated radiographs without the use of extreme positioning, and 17 papers discussed the use of extreme positioning to define spinopelvic mobility. DISCUSSION Our review suggests that the definitions of spinopelvic mobility is not consistent in the majority of published literature. We suggest descriptions of spinopelvic mobility independently consider spinal motion, hip motion, and pelvic position, while recognizing and describing their interdependence.
Collapse
Affiliation(s)
- Daniel B. Buchalter
- From the Department of Orthopedic Surgery, NYU Langone Health, New York, NY (Dr. Buchalter, Ms. Gall, Dr. Buckland, Dr. Schwarzkopf, Dr. Meftah, and Dr. Hepinstall); and the Melbourne Orthopaedic Group, Spine and Scoliosis Research Associates, Melbourne, Australia (Dr. Buckland)
| | - Ashley M. Gall
- From the Department of Orthopedic Surgery, NYU Langone Health, New York, NY (Dr. Buchalter, Ms. Gall, Dr. Buckland, Dr. Schwarzkopf, Dr. Meftah, and Dr. Hepinstall); and the Melbourne Orthopaedic Group, Spine and Scoliosis Research Associates, Melbourne, Australia (Dr. Buckland)
| | - Aaron J. Buckland
- From the Department of Orthopedic Surgery, NYU Langone Health, New York, NY (Dr. Buchalter, Ms. Gall, Dr. Buckland, Dr. Schwarzkopf, Dr. Meftah, and Dr. Hepinstall); and the Melbourne Orthopaedic Group, Spine and Scoliosis Research Associates, Melbourne, Australia (Dr. Buckland)
| | - Ran Schwarzkopf
- From the Department of Orthopedic Surgery, NYU Langone Health, New York, NY (Dr. Buchalter, Ms. Gall, Dr. Buckland, Dr. Schwarzkopf, Dr. Meftah, and Dr. Hepinstall); and the Melbourne Orthopaedic Group, Spine and Scoliosis Research Associates, Melbourne, Australia (Dr. Buckland)
| | - Morteza Meftah
- From the Department of Orthopedic Surgery, NYU Langone Health, New York, NY (Dr. Buchalter, Ms. Gall, Dr. Buckland, Dr. Schwarzkopf, Dr. Meftah, and Dr. Hepinstall); and the Melbourne Orthopaedic Group, Spine and Scoliosis Research Associates, Melbourne, Australia (Dr. Buckland)
| | - Matthew S. Hepinstall
- From the Department of Orthopedic Surgery, NYU Langone Health, New York, NY (Dr. Buchalter, Ms. Gall, Dr. Buckland, Dr. Schwarzkopf, Dr. Meftah, and Dr. Hepinstall); and the Melbourne Orthopaedic Group, Spine and Scoliosis Research Associates, Melbourne, Australia (Dr. Buckland)
| |
Collapse
|
4
|
Ameztoy Gallego J, Cruz Pardos A, Gomez Luque J, Cuadrado Rubio LE, Fernández Fernández R. Dislocation and survival rate of dual mobility cups in revision total hip arthroplasty in patients with high risk of instability. INTERNATIONAL ORTHOPAEDICS 2023:10.1007/s00264-023-05816-8. [PMID: 37085676 DOI: 10.1007/s00264-023-05816-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 04/13/2023] [Indexed: 04/23/2023]
Abstract
PURPOSE Instability remains as an unsolved complication after revision total hip arthroplasty (rTHA). Dual mobility (DM) cups have decreased dislocation rate in rTHA; however, there are few clinical studies that evaluate the risk of dislocation after rTHA in patients with high risk of instability. METHODS Between 2007 and 2019, 95 consecutive rTHA using a DM cup, in 93 patients with instability risk factors were retrospectively reviewed. Instability risk factors were defined as follows: deficient abductor mechanism (22.1%), previous dislocation (68.4%), Paprosky 3 acetabular bone defect (21.1%), neuromuscular disease (4.2%), lumbar spine arthrodesis (6.3%), and more than one previous surgery (33.6%). Mean follow-up was 4.3 ± 2.4 years. Clinical and radiographic parameters were reported. DM cup survival was determined using a Kaplan-Meier analysis with re-revision for any cause as the end-point. Surgical complications and re-dislocation rate was recorded. RESULTS Seven DM cups were re-revised; three due to aseptic loosening, three due to peri-prosthetic joint infection (PJI), and one due to instability. At seven years follow-up, the survival rate of the DM cup using re-revision for any reason as the end-point was 82.4% (95% confidence interval, 66.4-98.4%). There were 12 (12.6%) complications: two (2.1%) dislocations, six (6.3%) PJI, four (4.2%) peri-prosthetic fractures. CONCLUSION Our findings suggest DM cups are effective reducing dislocation rate in rTHA in patients with a high risk of instability, without increasing early aseptic loosening and with a low rate of dislocation. Nevertheless, longer follow-up is needed to confirm implant stability and dislocation rates in the long term.
Collapse
Affiliation(s)
- Juan Ameztoy Gallego
- Hospital Universitario La Paz, Paseo de La Castellana 261, 28046, Madrid, Spain.
| | - Ana Cruz Pardos
- Hospital Universitario La Paz, Paseo de La Castellana 261, 28046, Madrid, Spain
| | - Javier Gomez Luque
- Hospital Universitario La Paz, Paseo de La Castellana 261, 28046, Madrid, Spain
| | | | | |
Collapse
|
5
|
ÇATALTEPE A. The length of distal skin incision of the postero-lateral approach affects the cup inclination during the total hip arthroplasty. JOURNAL OF HEALTH SCIENCES AND MEDICINE 2022. [DOI: 10.32322/jhsm.1071852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Aim: The primary aim of the study was to determine whether the length of the distal skin incision of the posterolateral approach affects the cup inclination during total hip arthroplasty (THA).
Material and Method: In this study, a cohort of 71 consecutive patients who performed between January 2017 and December 2021 with unilateral THA using a posterolateral approach was retrospectively assessed. Two groups were formed according to acetabular cup inclination with normal anteversion angle. There were 56 hips in the inside group and 17 in the outside group. A curvilinear skin incision of around 13 cm was performed. Component position evaluation was carried out through a radiographic assessment of the acetabular component on an anteroposterior pelvis radiograph. The rate of an outlier was compared between groups according to the safe zone defined as 30° to 50° of inclination and 5° to 25° of anteversion, which was described by Lewinnek et al.
Results: No significant difference in the average total incision length was found between the two groups (p=0.207). While the average distal incision length was 7.91±0.62 cm (range, 6.8-9 cm) in the inside group and 6.37±0.21 cm (range, 6-6.7 cm) in the outside group. According to ROC analysis, a patient with ≤6.7 cm of the distal length of incision (DLI) was 5.71 times more likely to be outside than a patient with >6.7 cm of DLI. Seventeen hips (23.3%) were found outside the safe range. Substantial differences were observed regarding radiographic cup inclination between the two groups (p=0.0001). In the inside group, the average cup inclination was 44.11°±3.44° (range, 37°-50°), whereas, in the outside group, it was 55.41°±2.5° (range, 52°-59°). However, there were no significant differences in the average radiographic cup anteversion between the two groups (p=0.960). Although 11 of 17 (64.5%) patients were classified as obese (BMI ≥30) in the outside group experienced higher rates of inaccurate cup orientation, logistic regression analysis showed that the individual effects of obesity on the occurrence of the inaccurate cup position were not observed (p=0.884). One posterior hip dislocation occurred after one month postoperative in the outside group.
Conclusions: Longer distal portion of the skin incision of the posterolateral approach should be performed to achieve optimal operative inclination angles of the acetabular cup during THA. The surgeon must have no hesitation in extending the distal skin incision when adopting the posterolateral approach.
Collapse
|
6
|
Kort N, Stirling P, Pilot P, Müller JH. Clinical and surgical outcomes of robot-assisted versus conventional total hip arthroplasty: a systematic overview of meta-analyses. EFORT Open Rev 2021; 6:1157-1165. [PMID: 35839094 PMCID: PMC8693228 DOI: 10.1302/2058-5241.6.200121] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Robot-assisted total hip arthroplasty (THA), in comparison to conventional THA, improves radiographic outcomes, but it remains unclear whether it alters complication rates, clinical and functional outcomes, and implant survival. The purpose of this systematic overview was to summarize the findings of the most recent meta-analyses that compare clinical and surgical outcomes of robot-assisted versus conventional THA. Two readers independently conducted an electronic literature search, screening and data extraction from five electronic databases. Inclusion criteria were: meta-analyses evaluating robot-assisted versus conventional THA in terms of radiographic outcomes, clinical and functional scores, and complications and revision rates. The literature search returned 67 records, of which 14 were duplicates and 49 were excluded, leaving three meta-analyses published within the past two years for data extraction and analysis. The present overview of meta-analyses suggests that, compared to conventional THA (n = 3011), robot-assisted THA (n = 1813) improves component placement and reduces intraoperative complications. The overview also affirms that robot-assisted THA could extend surgery by 20 minutes, and increases risks of postoperative heterotopic ossification, dislocation, and revision. None of the meta-analyses found significant differences in clinical or functional scores between robot-assisted and conventional THA. Future studies and reviews should make a clear distinction between active and semi-active robotic assistance, address technology matureness, and describe the experience of surgeons with robotic assistance.
Cite this article: EFORT Open Rev 2021;6:1157-1165. DOI: 10.1302/2058-5241.6.200121
Collapse
|