Yadav R, Gerrickens MWM, Teijink JAW, Scheltinga MRM. Abnormal preoperative digital brachial index is associated with lower 2-year arteriovenous fistula access patency.
J Vasc Surg 2021;
74:237-245. [PMID:
33359237 DOI:
10.1016/j.jvs.2020.12.075]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 12/09/2020] [Indexed: 11/16/2022]
Abstract
OBJECTIVE
The aim of the present study was to assess whether a single measurement of the digital brachial index (DBI; systolic finger pressure/systemic pressure ratio), reflecting the arm's circulation, was associated with access patency in patients with severe chronic kidney disease scheduled for arteriovenous fistula (AVF) creation.
METHODS
A bilateral DBI was obtained using digital plethysmography just before construction of the patient's first AVF from January 2009 to December 2017 at one center. A DBI of 80% to 99% was considered normal, and a DBI of <80% (low) or DBI of ≥100% (high) were considered abnormal. DBI values ipsilateral to the AVF were used for analysis. The primary and secondary access patency rates were calculated using reported standards and compared using standard statistical techniques.
RESULTS
Data sets of 163 patients were obtained (69 women; age, 71 ± 12 years). The median follow-up was 40 weeks (range, 0-104 weeks; follow-up index, 99% ± 1%). Patients with abnormal preoperative DBI values had lower 2-year primary patency rates (low DBI, 25% ± 11%; high DBI, 28% ± 6%; normal DBI, 49% ± 8%; P = .018). After correction for age, sex, hypertension, diabetes mellitus, cardiovascular disease, smoking status, and a history of ipsilateral central venous catheter use, an adjusted model demonstrated that abnormal DBI values conferred an increased risk of primary patency failure (low DBI [<80%]: hazard ratio [HR], 2.25; 95% confidence interval [CI], 1.13-4.48; high DBI [≥100%]: HR, 1.74; 95% CI, 1.06-2.85; P < .030 for both). Patients with a low preoperative DBI had also had diminished secondary patency (HR, 2.86; 95% CI, 1.08-7.59; P = .035). In contrast, the diameters of the outflow veins did not determine access patency.
CONCLUSIONS
Patients with abnormal DBI values before AVF construction for hemodialysis had lower 2-year access patency rates compared with patients with a normal DBI. Plethysmographic finger measurements might have a role in the preoperative counseling of patients with severe chronic kidney disease requiring an AVF.