1
|
Abstract
BACKGROUND Cystic fibrosis (CF) is an inherited progressive life-limiting disease characterised by the build-up of abnormally thick, sticky mucus affecting mostly the lungs, pancreas, and digestive system. Airway clearance techniques (ACTs), traditionally referred to as chest physiotherapy, are recommended as part of a complex treatment programme for people with CF. The aim of an ACTs is to enhance mucociliary clearance and remove viscous secretions from the airways within the lung to prevent distal airway obstruction. This reduces the infective burden and associated inflammatory effects on the airway epithelia. There are a number of recognised ACTs, none of which have shown superiority in improving short-term outcomes related to mucus transport. This systematic review, which has been updated regularly since it was first published in 2000, considers the efficacy of ACTs compared to not performing any ACT in adults and children with CF. It is important to continue to review this evidence, particularly the long-term outcomes, given the recent introduction of highly effective modulator therapies and the improved health outcomes and potential changes to CF management associated with these drugs. OBJECTIVES To determine the effectiveness and acceptability of airway clearance techniques compared to no airway clearance techniques or cough alone in people with cystic fibrosis. SEARCH METHODS We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register, which comprises references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings, to 17 October 2022. We searched ongoing trials registers (Clinicaltrials.gov and the WHO International Clinical Trials Registry Platform) to 7 November 2022. SELECTION CRITERIA We included randomised or quasi-randomised studies that compared airway clearance techniques (chest physiotherapy) with no airway clearance techniques or spontaneous cough alone in people with CF. DATA COLLECTION AND ANALYSIS Both review authors independently assessed study eligibility, extracted data, and assessed the risk of bias of the included studies. We used GRADE methodology to assess the certainty of the evidence. MAIN RESULTS We included 11 cross-over studies (153 participants) and one parallel study (41 participants). There were differences between studies in how the interventions were delivered, with several intervention groups combining more than one ACT. One study used autogenic drainage; five used conventional chest physiotherapy; nine used positive expiratory pressure (PEP), with one study varying the water pressure between arms; three studies used oscillating PEP; two used exercise; and two used high-frequency chest wall oscillation (HFCWO). Of the 12 included studies, 10 were single-treatment studies, and two delivered the intervention over two consecutive days (once daily in one study, twice daily in the second). This substantial heterogeneity in the treatment interventions precluded pooling of data for meta-analysis. Blinding of participants, caregivers, and clinicians is impossible in airway clearance studies; we therefore judged all studies at unclear risk of performance bias. Lack of information in eight studies made assessment of risk of bias unclear for most other domains. We rated the certainty of evidence as low or very low due to the short-term cross-over trial design, small numbers of participants, and uncertain risk of bias across most or all domains. Six studies (84 participants) reported no effect on pulmonary function variables following intervention; but one study (14 participants) reported an improvement in pulmonary function following the intervention in some of the treatment groups. Two studies reported lung clearance index: one (41 participants) found a variable response to treatment with HFCWO, whilst another (15 participants) found no effect on lung clearance index with PEP therapy (low-certainty evidence). Five studies (55 participants) reported that ACTs, including coughing, increased radioactive tracer clearance compared to control, while a further study (eight participants) reported no improvement in radioactive tracer clearance when comparing PEP to control, although coughing was discouraged during the PEP intervention. We rated the certainty of evidence on the effect of ACTs on radioactive tracer clearance as very low. Four studies (46 participants) investigated the weight of mucus cleared from the lungs and reported greater secretions during chest physiotherapy compared to a control. One study (18 participants) reported no differences in sputum weight (very low-certainty evidence). AUTHORS' CONCLUSIONS The evidence from this review shows that ACTs may have short-term effects on increasing mucus transport in people with CF. All included studies had short-term follow-up; consequently, we were unable to draw any conclusions on the long-term effects of ACTs compared to no ACTs in people with CF. The evidence in this review represents the use of airway clearance techniques in a CF population before widespread use of cystic fibrosis transmembrane conductance regulator (CFTR) modulators. Further research is needed to determine the effectiveness and acceptability of airway clearance in those treated with highly effective CFTR modulators.
Collapse
Affiliation(s)
- Louise Warnock
- Oxford Adult Cystic Fibrosis Centre, Oxford Centre for Respiratory Medicine, The Churchill Hospital, Oxford, UK
| | - Alison Gates
- Oxford Adult Cystic Fibrosis Centre, Oxford Centre for Respiratory Medicine, The Churchill Hospital, Oxford, UK
| |
Collapse
|
2
|
Andrejeva J, Mockute E, Sniepiene G, Malyško E, Istomina N, Hendrixson V. The impact of WATSU as Physiotherapy Method on Fatigue for People Diagnosed with Multiple Sclerosis. ACTA BALNEOLOGICA 2023. [DOI: 10.36740/abal202301103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
Abstract
Aim: To identify the impact of WATSU method on fatigue which has an impact on sleep and quality of life, pain and depression or its
aggravation.
Materials and Methods: The study involved the four participants. The following instruments were used: Multiple Sclerosis Quality of Life questionnaire; Pittsburgh Sleep Quality Index; Burns Depression Checklist; Fatigue Impact Scale. The study was carried out in medical center in Lithuania from 09-11-2019 till 18-01-2020 during 10 weeks. Each participant of the study received ten WATSU sessions. The research data was processed using SPSS Statistics 20. Qualitative Outcome Measures were conducted by content analysis, observation, semi-structured individual interview methods.
Results: After 10 sessions, fatigue lessened in all people investigated. Initially, the average of fatigue was 70 points and decreased to 34 points after the investigation. The average sleep quality index was as high as 5 points, after ten weeks the average decreased to 3 points. Changes in assessment of major to mild depression: initially, the average was 36 points, which decreased to 14 points after ten weeks.
Conclusions: The WATSU method was effective in reducing fatigue as a physiotherapy method. Along with changes in fatigue, the Pittsburgh Sleep Quality Index decreased, energy and motivation increased, quality of life improved, level of depression reduced, and the change was statistically significant. While assessing the quality of life, pain was found to be decreased – it became less frequent after ten weeks of sessions and less intense or even absent, its influence on daily activities decreased.
Collapse
Affiliation(s)
- Julija Andrejeva
- Klaipeda State University of Applied Sciences, Klaipeda, Lithuania
| | - Elinga Mockute
- Klaipeda State University of Applied Sciences, Klaipeda, Lithuania
| | | | | | | | | |
Collapse
|
3
|
Methods Used to Evaluate the Immediate Effects of Airway Clearance Techniques in Adults with Cystic Fibrosis: A Systematic Review and Meta-Analysis. J Clin Med 2021; 10:jcm10225280. [PMID: 34830562 PMCID: PMC8625729 DOI: 10.3390/jcm10225280] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 11/01/2021] [Accepted: 11/08/2021] [Indexed: 12/17/2022] Open
Abstract
This review reports on methods used to evaluate airway clearance techniques (ACT) in adults with CF and examined data for evidence of any effect. Sixty-eight studies described ACT in adequate detail and were included in this review. Frequently reported outcomes were sputum expectoration (72%) and spirometric lung function (60%). Compared with cough alone, following any ACT, there was a trend for greater sputum wet weight, however FEV1 was not different. The mean (95% CI) within-group effect for sputum wet weight following any ACT was 12.43 g (9.28 to 15.58) (n = 30 studies) and for FEV1 was 0.03 L (−0.17 to 0.24) (n = 14 studies). Meta-regression demonstrated that, when compared with cough alone, greater sputum wet weight was reported in groups that received additional ACT by between 2.45 and 3.94 g (F3,66 = 2.97, p = 0.04). These data suggest the addition of ACT to cough alone may optimise sputum clearance; however, FEV1 lacked sensitivity to detect this change. Importantly, this review highlights the lack of appropriate measures to assess ACT efficacy.
Collapse
|
4
|
Abstract
BACKGROUND Chest physiotherapy is widely prescribed to assist the clearance of airway secretions in people with cystic fibrosis. Oscillating devices generate intra- or extra-thoracic oscillations orally or external to the chest wall. Internally they create variable resistances within the airways, generating controlled oscillating positive pressure which mobilises mucus. Extra-thoracic oscillations are generated by forces outside the respiratory system, e.g. high frequency chest wall oscillation. This is an update of a previously published review. OBJECTIVES To identify whether oscillatory devices, oral or chest wall, are effective for mucociliary clearance and whether they are equivalent or superior to other forms of airway clearance in the successful management of secretions in people with cystic fibrosis. SEARCH METHODS We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches and hand searches of relevant journals and abstract books of conference proceedings. Latest search of the Cystic Fibrosis Trials Register: 29 July 2019. In addition we searched the trials databases ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform. Latest search of trials databases: 15 August 2019. SELECTION CRITERIA Randomised controlled studies and controlled clinical studies of oscillating devices compared with any other form of physiotherapy in people with cystic fibrosis. Single-treatment interventions (therapy technique used only once in the comparison) were excluded. DATA COLLECTION AND ANALYSIS Two authors independently applied the inclusion criteria to publications, assessed the quality of the included studies and assessed the evidence using GRADE. MAIN RESULTS The searches identified 82 studies (330 references); 39 studies (total of 1114 participants) met the inclusion criteria. Studies varied in duration from up to one week to one year; 20 of the studies were cross-over in design. The studies also varied in type of intervention and the outcomes measured, data were not published in sufficient detail in most of these studies, so meta-analysis was limited. Few studies were considered to have a low risk of bias in any domain. It is not possible to blind participants and clinicians to physiotherapy interventions, but 13 studies did blind the outcome assessors. The quality of the evidence across all comparisons ranged from low to very low. Forced expiratory volume in one second was the most frequently measured outcome and while many of the studies reported an improvement in those people using a vibrating device compared to before the study, there were few differences when comparing the different devices to each other or to other airway clearance techniques. One study identified an increase in frequency of exacerbations requiring antibiotics whilst using high frequency chest wall oscillation when compared to positive expiratory pressure (low-quality evidence). There were some small but significant changes in secondary outcome variables such as sputum volume or weight, but not wholly in favour of oscillating devices and due to the low- or very low-quality evidence, it is not clear whether these were due to the particular intervention. Participant satisfaction was reported in 13 studies but again with low- or very low-quality evidence and not consistently in favour of an oscillating device, as some participants preferred breathing techniques or techniques used prior to the study interventions. The results for the remaining outcome measures were not examined or reported in sufficient detail to provide any high-level evidence. AUTHORS' CONCLUSIONS There was no clear evidence that oscillation was a more or less effective intervention overall than other forms of physiotherapy; furthermore there was no evidence that one device is superior to another. The findings from one study showing an increase in frequency of exacerbations requiring antibiotics whilst using an oscillating device compared to positive expiratory pressure may have significant resource implications. More adequately-powered long-term randomised controlled trials are necessary and outcomes measured should include frequency of exacerbations, individual preference, adherence to therapy and general satisfaction with treatment. Increased adherence to therapy may then lead to improvements in other parameters, such as exercise tolerance and respiratory function. Additional evidence is needed to evaluate whether oscillating devices combined with other forms of airway clearance is efficacious in people with cystic fibrosis.There may also be a requirement to consider the cost implication of devices over other forms of equally advantageous airway clearance techniques. Using the GRADE method to assess the quality of the evidence, we judged this to be low or very low quality, which suggests that further research is very likely to have an impact on confidence in any estimate of effect generated by future interventions.
Collapse
Affiliation(s)
- Lisa Morrison
- West of Scotland Adult CF Unit, Queen Elizabeth University Hospital (The Southern General Hospital), Glasgow, UK
| | | |
Collapse
|
5
|
Wilson LM, Morrison L, Robinson KA. Airway clearance techniques for cystic fibrosis: an overview of Cochrane systematic reviews. Cochrane Database Syst Rev 2019; 1:CD011231. [PMID: 30676656 PMCID: PMC6353051 DOI: 10.1002/14651858.cd011231.pub2] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Cystic fibrosis is a life-limiting genetic condition in which thick mucus builds up in the lungs, leading to infections, inflammation, and eventually, deterioration in lung function. To clear their lungs of mucus, people with cystic fibrosis perform airway clearance techniques daily. There are various airway clearance techniques, which differ in terms of the need for assistance or equipment, and cost. OBJECTIVES To summarise the evidence from Cochrane Reviews on the effectiveness and safety of various airway clearance techniques in people with cystic fibrosis. METHODS For this overview, we included Cochrane Reviews of randomised or quasi-randomised controlled trials (including cross-over trials) that evaluated an airway clearance technique (conventional chest physiotherapy, positive expiratory pressure (PEP) therapy, high-pressure PEP therapy, active cycle of breathing techniques, autogenic drainage, airway oscillating devices, external high frequency chest compression devices and exercise) in people with cystic fibrosis.We searched the Cochrane Database of Systematic Reviews on 29 November 2018.Two review authors independently evaluated reviews for eligibility. One review author extracted data from included reviews and a second author checked the data for accuracy. Two review authors independently graded the quality of reviews using the ROBIS tool. We used the GRADE approach for assessing the overall strength of the evidence for each primary outcome (forced expiratory volume in one second (FEV1), individual preference and quality of life). MAIN RESULTS We included six Cochrane Reviews, one of which compared any type of chest physiotherapy with no chest physiotherapy or coughing alone and the remaining five reviews included head-to-head comparisons of different airway clearance techniques. All the reviews were considered to have a low risk of bias. However, the individual trials included in the reviews often did not report sufficient information to adequately assess risk of bias. Many trials did not sufficiently report on outcome measures and had a high risk of reporting bias.We are unable to draw definitive conclusions for comparisons of airway clearance techniques in terms of FEV1, except for reporting no difference between PEP therapy and oscillating devices after six months of treatment, mean difference -1.43% predicted (95% confidence interval -5.72 to 2.87); the quality of the body of evidence was graded as moderate. The quality of the body of evidence comparing different airway clearance techniques for other outcomes was either low or very low. AUTHORS' CONCLUSIONS There is little evidence to support the use of one airway clearance technique over another. People with cystic fibrosis should choose the airway clearance technique that best meets their needs, after considering comfort, convenience, flexibility, practicality, cost, or some other factor. More long-term, high-quality randomised controlled trials comparing airway clearance techniques among people with cystic fibrosis are needed.
Collapse
Affiliation(s)
- Lisa M Wilson
- Johns Hopkins UniversityEvidence‐based Practice CenterHampton House, 6th Floor624 North BroadwayBaltimoreMDUSA21205‐1901
| | - Lisa Morrison
- Queen Elizabeth University Hospital (The Southern General Hospital)West of Scotland Adult CF Unit1345 Govan RoadGlasgowUKG51 4TF
| | - Karen A Robinson
- Johns Hopkins UniversityDepartment of Medicine1830 E. Monument St., Suite 8068BaltimoreMDUSA21287
| | | |
Collapse
|
6
|
Abstract
BACKGROUND Chest physiotherapy is widely prescribed to assist the clearance of airway secretions in people with cystic fibrosis. Oscillating devices generate intra- or extra-thoracic oscillations orally or external to the chest wall. Internally they create variable resistances within the airways, generating controlled oscillating positive pressure which mobilises mucus. Extra-thoracic oscillations are generated by forces outside the respiratory system, e.g. high frequency chest wall oscillation. This is an update of a previously published review. OBJECTIVES To identify whether oscillatory devices, oral or chest wall, are effective for mucociliary clearance and whether they are equivalent or superior to other forms of airway clearance in the successful management of secretions in people with cystic fibrosis. SEARCH METHODS We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches and hand searches of relevant journals and abstract books of conference proceedings. Latest search of the Cystic Fibrosis Trials Register: 27 April 2017.In addition we searched the trials databases ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform. Latest search of trials databases: 26 April 2017. SELECTION CRITERIA Randomised controlled studies and controlled clinical studies of oscillating devices compared with any other form of physiotherapy in people with cystic fibrosis. Single-treatment interventions (therapy technique used only once in the comparison) were excluded. DATA COLLECTION AND ANALYSIS Two authors independently applied the inclusion criteria to publications and assessed the quality of the included studies. MAIN RESULTS The searches identified 76 studies (302 references); 35 studies (total of 1138 participants) met the inclusion criteria. Studies varied in duration from up to one week to one year; 20 of the studies were cross-over in design. The studies also varied in type of intervention and the outcomes measured, data were not published in sufficient detail in most of these studies, so meta-analysis was limited. Few studies were considered to have a low risk of bias in any domain. It is not possible to blind participants and clinicians to physiotherapy interventions, but 11 studies did blind the outcome assessors.Forced expiratory volume in one second was the most frequently measured outcome. One long-term study (seven months) compared oscillatory devices with either conventional physiotherapy or breathing techniques and found statistically significant differences in some lung function parameters in favour of oscillating devices. One study identified an increase in frequency of exacerbations requiring antibiotics whilst using high frequency chest wall oscillation when compared to positive expiratory pressure. There were some small but significant changes in secondary outcome variables such as sputum volume or weight, but not wholly in favour of oscillating devices. Participant satisfaction was reported in 15 studies but this was not specifically in favour of an oscillating device, as some participants preferred breathing techniques or techniques used prior to the study interventions. The results for the remaining outcome measures were not examined or reported in sufficient detail to provide any high level evidence. AUTHORS' CONCLUSIONS There was no clear evidence that oscillation was a more or less effective intervention overall than other forms of physiotherapy; furthermore there was no evidence that one device is superior to another. The findings from one study showing an increase in frequency of exacerbations requiring antibiotics whilst using an oscillating device compared to positive expiratory pressure may have significant resource implications. More adequately-powered long-term randomised controlled trials are necessary and outcomes measured should include frequency of exacerbations, individual preference, adherence to therapy and general satisfaction with treatment. Increased adherence to therapy may then lead to improvements in other parameters, such as exercise tolerance and respiratory function. Additional evidence is needed to evaluate whether oscillating devices combined with other forms of airway clearance is efficacious in people with cystic fibrosis.There may also be a requirement to consider the cost implication of devices over other forms of equally advantageous airway clearance techniques. Using the GRADE method to assess the quality of the evidence, we judged this to be low or very low quality, which suggests that further research is very likely to have an impact on confidence in any estimate of effect generated by future interventions.
Collapse
Affiliation(s)
- Lisa Morrison
- Queen Elizabeth University Hospital (The Southern General Hospital)West of Scotland Adult CF Unit1345 Govan RoadGlasgowUKG51 4TF
| | - Stephanie Milroy
- Queen Elizabeth University Hospital1345 Govan RoadGlasgowUKG51 4TF
| |
Collapse
|
7
|
Gursli S, Sandvik L, Bakkeheim E, Skrede B, Stuge B. Evaluation of a novel technique in airway clearance therapy - Specific Cough Technique (SCT) in cystic fibrosis: A pilot study of a series of N-of-1 randomised controlled trials. SAGE Open Med 2017; 5:2050312117697505. [PMID: 28540046 PMCID: PMC5433674 DOI: 10.1177/2050312117697505] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Accepted: 02/06/2017] [Indexed: 11/15/2022] Open
Abstract
Objectives: The aim of this pilot study was to evaluate the efficacy, safety and participants’ perception of a novel technique in airway clearance therapy – specific cough technique in cystic fibrosis. Methods: We conducted randomised controlled individual trials (N-of-1 randomised controlled trials) in six adults. Each trial included 8 weeks of treatment with two interventions each week, one with specific cough technique and one with forced expiration technique. The efficacy was investigated by a blinded assessor measuring wet weight of sputum (g) after each session. Perceived usefulness and preference was self-reported at the end of study. Additional measurements included oxygen saturation and heart rate before and after each session and lung function (week 2). Results: Three of six participants produced significantly higher mean sputum weight when using specific cough technique, differences being 21%, 38% and 23%, respectively. In three of the six participants, mean sputum weight was lower after forced expiration technique than after specific cough technique in each of the eight treatment pairs. Participant-reported outcomes were completed in all participants. Specific cough technique was reported to be easier to use in daily treatments and more normalising in everyday life. Conclusion: Specific cough technique was well tolerated and accepted by the participants with cystic fibrosis. Specific cough technique was non-inferior to forced expiration technique in terms of sputum production, thus specific cough technique appears to represent a promising alternative for clearing sputum in airway clearance therapy.
Collapse
Affiliation(s)
- Sandra Gursli
- Norwegian Resource Centre for Cystic Fibrosis, Oslo University Hospital, Oslo, Norway
| | - Leiv Sandvik
- Oslo Centre for Biostatistics & Epidemiology (OCBE), Research Support Services, Oslo University Hospital, Oslo, Norway
| | - Egil Bakkeheim
- Norwegian Resource Centre for Cystic Fibrosis, Oslo University Hospital, Oslo, Norway
| | - Bjørn Skrede
- Department of Pulmonary Medicine, Oslo University Hospital, Oslo, Norway
| | - Britt Stuge
- Department of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
8
|
Abstract
BACKGROUND Chest physiotherapy is widely used in people with cystic fibrosis in order to clear mucus from the airways. This is an updated version of previously published reviews. OBJECTIVES To determine the effectiveness and acceptability of chest physiotherapy compared to no treatment or spontaneous cough alone to improve mucus clearance in cystic fibrosis. SEARCH METHODS We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register which comprises references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings.Date of the most recent search of the Group's Cystic Fibrosis Trials Register: 02 June 2015. SELECTION CRITERIA Randomised or quasi-randomised clinical studies in which a form of chest physiotherapy (airway clearance technique) were taken for consideration in people with cystic fibrosis compared with either no physiotherapy treatment or spontaneous cough alone. DATA COLLECTION AND ANALYSIS Both authors independently assessed study eligibility, extracted data and assessed the risk of bias in the included studies. There was heterogeneity in the published outcomes, with variable reporting which meant pooling of the data for meta-analysis was not possible. MAIN RESULTS The searches identified 157 studies, of which eight cross-over studies (data from 96 participants) met the inclusion criteria. There were differences between studies in the way that interventions were delivered, with several of the intervention groups combining more than one treatment modality. One included study looked at autogenic drainage, six considered conventional chest physiotherapy, three considered oscillating positive expiratory pressure, seven considered positive expiratory pressure and one considered high pressure positive expiratory pressure. Of the eight studies, six were single-treatment studies and in two, the treatment intervention was performed over two consecutive days (once daily in one, twice daily in the other). This enormous heterogeneity in the treatment interventions prevented any meta-analyses from being performed. Blinding of participants, caregivers or clinicians in airway clearance studies is impossible; therefore this was not considered as a high risk of bias in the included studies. Lack of protocol data made assessment of risk of bias unclear for the majority of other criteria.Four studies, involving 28 participants, reported a higher amount of expectorated secretions during chest physiotherapy as compared to a control. One study, involving 18 participants, reported no significant differences in sputum weight. In five studies radioactive tracer clearance was used as an outcome variable. In three of these (28 participants) it was reported that chest physiotherapy, including coughing, increased radioactive tracer clearance as compared to the control period. One study (12 participants) reported increased radioactive tracer clearance associated with all interventions compared to control, although this was only reported to have reached significance for postural drainage with percussion and vibrations; and the remaining study (eight participants) reported no significant difference in radioactive tracer clearance between chest physiotherapy, without coughing, compared to the control period. Three studies, involving 42 participants reported no significant effect on pulmonary function variables following intervention; but one further study did report significant improvement in pulmonary function following the intervention in some of the treatment groups. AUTHORS' CONCLUSIONS The results of this review show that airway clearance techniques have short-term effects in the terms of increasing mucus transport. No evidence was found on which to draw conclusions concerning the long-term effects.
Collapse
Affiliation(s)
- Louise Warnock
- Oxford Centre for Respiratory Medicine, The Churchill HospitalOxford Adult Cystic Fibrosis CentreOld RoadHeadingtonOxfordUKOX3 7LJ
| | - Alison Gates
- Oxford Centre for Respiratory Medicine, The Churchill HospitalOxford Adult Cystic Fibrosis CentreOld RoadHeadingtonOxfordUKOX3 7LJ
| | | |
Collapse
|
9
|
Gastaldi AC, Paredi P, Talwar A, Meah S, Barnes PJ, Usmani OS. Oscillating Positive Expiratory Pressure on Respiratory Resistance in Chronic Obstructive Pulmonary Disease With a Small Amount of Secretion: A Randomized Clinical Trial. Medicine (Baltimore) 2015; 94:e1845. [PMID: 26496331 PMCID: PMC4620777 DOI: 10.1097/md.0000000000001845] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
This study aims to evaluate the acute effects of an oscillating positive expiratory pressure device (flutter) on airways resistance in patients with chronic obstructive pulmonary disease (COPD).Randomized crossover study: 15 COPD outpatients from Asthma Lab-Royal Brompton Hospital underwent spirometry, impulse oscillometry (IOS) for respiratory resistance (R) and reactance (X), and fraction exhaled nitric oxide (FeNO) measures.Thirty minutes of flutter exercises: a "flutter-sham" procedure was used as a control, and airway responses after a short-acting bronchodilator were also assessed.Respiratory system resistance (R): in COPD patients an increase in X5insp (-0.21 to -0.33 kPa/L/s) and Fres (24.95 to 26.16 Hz) occurred immediately after flutter exercises without bronchodilator. Following 20 min of rest, a decrease in the R5, ΔR5, R20, X5, and Ax was observed, with R5, R20, and X5 values lower than baseline, with a moderate effect size; there were no changes in FeNO levels or spirometry.The use of flutter can decrease the respiratory system resistance and reactance and expiratory flow limitation in stable COPD patients with small amounts of secretions.
Collapse
Affiliation(s)
- Ada Clarice Gastaldi
- From the Physiotherapy Course, School of Medicine of Ribeirão Preto, São Paulo University, Brazil (ACG); Airway Disease Section, National Heart and Lung Institute, Imperial College London& Royal Brompton Hospital, United Kingdom (PP, SM, PJB, OSU); and Department of Physiology, All India Institute of Medical Sciences, India (AT)
| | | | | | | | | | | |
Collapse
|
10
|
Schitter AM, Nedeljkovic M, Baur H, Fleckenstein J, Raio L. Effects of Passive Hydrotherapy WATSU (WaterShiatsu) in the Third Trimester of Pregnancy: Results of a Controlled Pilot Study. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE : ECAM 2015; 2015:437650. [PMID: 25815033 PMCID: PMC4359846 DOI: 10.1155/2015/437650] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Revised: 08/26/2014] [Accepted: 09/15/2014] [Indexed: 12/03/2022]
Abstract
Background. WATSU (WaterShiatsu) is a complementary therapeutic treatment method comprising passive stretches and massage techniques administered in 35°C warm water. Pregnant women claim safe methods to reduce pain, stress, and fatigue. Therefore, we conducted a pilot study evaluating the effects of WATSU on pregnancy-related complaints in third trimester pregnant women. Methods. Nine healthy pregnant women at gestational week ≥34 were included in an intervention group (receiving WATSU) and compared to eight women in a passive control group (receiving no treatment). WATSU was performed on days 1 and 4 of the study, accompanied by ultrasound examinations. Outcomes include physiological and psychometric as well as qualitative data. Participants in the control group completed questionnaires only. Results. WATSU was found to significantly lower participants' levels of stress and pain and to improve their mental health-related quality of life and mood. In comparison to the passive control group, participants in the intervention group reported reduction in perceived stress from day 1 to day 8 (P = 0.036, Cohen's f = 0.57). Qualitative data indicate that WATSU was appreciated as enjoyable and deeply relaxing. No negative side effects were reported. Conclusion. Our findings support the notion that WATSU yields therapeutic benefits for pregnant women and warrant further research. This study has been registered at ClinicalTrials.gov: NCT01708018.
Collapse
Affiliation(s)
- Agnes M. Schitter
- Department of TCM/Acupuncture, Institute of Complementary Medicine IKOM, University of Bern, Imhoof-Pavillon, Inselspital, 3010 Bern, Switzerland
| | - Marko Nedeljkovic
- Department of TCM/Acupuncture, Institute of Complementary Medicine IKOM, University of Bern, Imhoof-Pavillon, Inselspital, 3010 Bern, Switzerland
| | - Heiner Baur
- Department of Health, Bern University of Applied Sciences, Murtenstrasse 10, 3008 Bern, Switzerland
| | - Johannes Fleckenstein
- Department of TCM/Acupuncture, Institute of Complementary Medicine IKOM, University of Bern, Imhoof-Pavillon, Inselspital, 3010 Bern, Switzerland
| | - Luigi Raio
- Department of Obstetrics and Gynecology Inselspital, University Hospital of Bern, Effingerstrasse 102, 3010 Bern, Switzerland
| |
Collapse
|
11
|
Abstract
BACKGROUND Chest physiotherapy is widely prescribed to assist the clearance of airway secretions in people with cystic fibrosis. Oscillating devices generate intra- or extra-thoracic oscillations orally or external to the chest wall. Internally they create variable resistances within the airways, generating controlled oscillating positive pressure which mobilises mucus. Extra-thoracic oscillations are generated by forces outside the respiratory system, e.g. high frequency chest wall oscillation. OBJECTIVES To identify whether oscillatory devices, oral or chest wall, are effective for mucociliary clearance and whether they are equivalent or superior to other forms of airway clearance in the successful management of secretions in people with cystic fibrosis. SEARCH METHODS We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches and hand searches of relevant journals and abstract books of conference proceedings. Latest search of the Cystic Fibrosis Trials Register: 13 January 2014. SELECTION CRITERIA Randomised controlled studies and controlled clinical studies of oscillating devices compared with any other form of physiotherapy in people with cystic fibrosis. Single-treatment interventions (therapy technique used only once in the comparison) were excluded. DATA COLLECTION AND ANALYSIS Two authors independently applied the inclusion criteria to publications and assessed the quality of the included studies. MAIN RESULTS The searches identified 68 studies with a total of 288 references; 35 studies (total of 1050 participants) met the inclusion criteria. Studies varied in duration from up to one week to one year; 20 of the studies were cross-over in design. The studies also varied in type of intervention and the outcomes measured, furthermore data were not published in sufficient detail in most of these studies, so meta-analysis was limited. Few studies were considered to have a low risk of bias in any domain. It is not possible to blind participants and clinicians to physiotherapy interventions, but 10 studies did blind the outcome assessors.Forced expiratory volume in one second was the most frequently measured outcome. One long-term study (seven months) compared oscillatory devices with either conventional physiotherapy or breathing techniques and found statistically significant differences in some lung function parameters in favour of oscillating devices. One study identified an increase in frequency of exacerbations requiring antibiotics whilst using high frequency chest wall oscillation when compared to positive expiratory pressure. There were some small but significant changes in secondary outcome variables such as sputum volume or weight, but not wholly in favour of oscillating devices. Participant satisfaction was reported in 15 studies but this was not specifically in favour of an oscillating device, as some participants preferred breathing techniques or techniques used prior to the study interventions. The results for the remaining outcome measures were not examined or reported in sufficient detail to provide any high level evidence. AUTHORS' CONCLUSIONS There was no clear evidence that oscillation was a more or less effective intervention overall than other forms of physiotherapy; furthermore there was no evidence that one device is superior to another. The findings from one study showing an increase in frequency of exacerbations requiring antibiotics whilst using an oscillating device compared to positive expiratory pressure may have significant resource implications. More adequately-powered long-term randomised controlled trials are necessary and outcomes measured should include frequency of exacerbations, patient preference, adherence to therapy and general satisfaction with treatment. Increased adherence to therapy may then lead to improvements in other parameters, such as exercise tolerance and respiratory function. Additional evidence is needed to evaluate whether oscillating devices combined with other forms of airway clearance is efficacious in people with cystic fibrosis.
Collapse
Affiliation(s)
- Lisa Morrison
- West of Scotland Adult CF Unit, Gartnavel General Hospital, 1053 Great Western Road, Glasgow, UK, G12 0YN
| | | |
Collapse
|
12
|
Warnock L, Gates A, van der Schans CP. Chest physiotherapy compared to no chest physiotherapy for cystic fibrosis. Cochrane Database Syst Rev 2013:CD001401. [PMID: 24006212 DOI: 10.1002/14651858.cd001401.pub2] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Chest physiotherapy is widely used in people with cystic fibrosis in order to clear mucus from the airways. OBJECTIVES To determine the effectiveness and acceptability of chest physiotherapy compared to no treatment or spontaneous cough alone to improve mucus clearance in cystic fibrosis. SEARCH METHODS We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register which comprises references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings.Date of the most recent search of the Group's Cystic Fibrosis Trials Register: 04 February 2013. SELECTION CRITERIA Randomised or quasi-randomised clinical studies in which a form of chest physiotherapy (airway clearance technique) were taken for consideration in people with cystic fibrosis compared with either no physiotherapy treatment or spontaneous cough alone. DATA COLLECTION AND ANALYSIS Both authors independently assessed study eligibility, extracted data and assessed study quality. There was heterogeneity in the published outcomes, with variable reporting which meant pooling of the data for meta-analysis was not possible. MAIN RESULTS The searches identified 144 studies, of which eight cross-over studies (data from 96 participants) met the inclusion criteria. There were differences between studies in the way that interventions were delivered, with several of the intervention groups combining more than one treatment modality. One included study looked at autogenic drainage, six considered conventional chest physiotherapy, three considered oscillating positive expiratory pressure, seven considered positive expiratory pressure and one considered high pressure positive expiratory pressure. Of the eight studies, six were single-treatment studies and in two, the treatment intervention was performed over two consecutive days (once daily in one, twice daily in the other). This enormous heterogeneity in the treatment interventions prevented any meta-analyses from being performed.Four studies, involving 28 participants, reported a higher amount of expectorated secretions during chest physiotherapy as compared to a control. One study, involving 18 participants, reported no significant differences in sputum weight. In five studies radioactive tracer clearance was used as an outcome variable. In three of these (28 participants) it was reported that chest physiotherapy, including coughing, increased radioactive tracer clearance as compared to the control period. One study (12 participants) reported increased radioactive tracer clearance associated with all interventions compared to control, although this was only reported to have reached significance for postural drainage with percussion and vibrations; and the remaining study (eight participants) reported no significant difference in radioactive tracer clearance between chest physiotherapy, without coughing, compared to the control period. Three studies, involving 42 participants reported no significant effect on pulmonary function variables following intervention; but one further study did report significant improvement in pulmonary function following the intervention in some of the treatment groups. AUTHORS' CONCLUSIONS The results of this review show that airway clearance techniques have short-term effects in the terms of increasing mucus transport. No evidence was found on which to draw conclusions concerning the long-term effects.
Collapse
Affiliation(s)
- Louise Warnock
- Oxford Adult Cystic Fibrosis Centre, Oxford Centre for Respiratory Medicine, The Churchill Hospital, Old Road, Headington, Oxford, UK, OX3 7LJ
| | | | | |
Collapse
|