1
|
Battista F, Ficarelli R, Perrotta A, Gualtieri P, Casciola CM, Romano GP, Taurino M. The Fluid-Dynamics of Endo Vascular Aneurysm Sealing (EVAS) System failure. Cardiovasc Eng Technol 2021; 12:300-310. [PMID: 33565030 PMCID: PMC8169503 DOI: 10.1007/s13239-021-00520-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 01/13/2021] [Indexed: 12/14/2022]
Abstract
Purpose The main objective of this work is to investigate hemodynamics phenomena occurring in EVAS (Endo Vascular Aneurysm Sealing), to understand if and how they could lead to type 1a endoleaks and following re-intervention. To this aim, methods based on computational fluid mechanics are implemented as a tool for checking the behavior of a specific EVAS configuration, starting from the post-operative conditions. Pressure and velocity fields are detailed and compared, for two configurations of the Nellix, one as attained after correct implantation and the other in pathological conditions, as a consequence of migration or dislocation of endobags. Methods The computational fluid dynamics (CFD) approach is used to simulate the behavior of blood within a segment of the aorta, before and after the abdominal bifurcation. The adopted procedure allows reconstructing the detailed vascular geometry from high-resolution computerized tomography (CT scan) and generating the mesh on which the equations of fluid mechanics are discretized and solved, in order to derive pressure and velocity field during heartbeats. Results The main results are obtained in terms of local velocity fields and wall pressures. Within the endobags, velocities are usually quite regular during the whole cardiac cycle for the post-implanted condition, whereas they are more irregular for the migrated case. The largest differences among the two cases are observed in the shape and location of the recirculation region in the rear part of the aorta and the region between the endobags, with the formation of a gap due to the migration of one or both of the two. In this gap, the pressure fields are highly different among the two conditions, showing pressure peaks and pressure gradients at least four times larger for the migrated case in comparison to the post-implanted condition. Conclusions In this paper, the migration of one or both endobags is supposed to be related to the existing differential pressures acting in the gap formed between the two, which could go on pushing the two branches one away from the other, thus causing aneurysm re-activation and endoleaks. Regions of flow recirculation and low-pressure drops are revealed only in case of endobag migration and in presence of an aneurysm. These regions are supposed to lead to possible plaque formation and atherosclerosis.
Collapse
Affiliation(s)
- F Battista
- Department of Mechanical and Aerospace Engineering, Sapienza University of Roma, Roma, Italy.
| | - R Ficarelli
- Department of Clinical and Molecular Medicine, Sapienza University of Roma, Roma, Italy
| | - A Perrotta
- Department of Mechanical and Aerospace Engineering, Sapienza University of Roma, Roma, Italy
| | - P Gualtieri
- Department of Mechanical and Aerospace Engineering, Sapienza University of Roma, Roma, Italy
| | - C M Casciola
- Department of Mechanical and Aerospace Engineering, Sapienza University of Roma, Roma, Italy
| | - G P Romano
- Department of Mechanical and Aerospace Engineering, Sapienza University of Roma, Roma, Italy
| | - M Taurino
- Department of Clinical and Molecular Medicine, Sapienza University of Roma, Roma, Italy
| |
Collapse
|
2
|
Proper technical procedures improved outcomes in a retrospective analysis of EVAS FORWARD IDE trial 3-year results. J Vasc Surg 2020; 72:918-930.e2. [DOI: 10.1016/j.jvs.2019.11.039] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Accepted: 11/12/2019] [Indexed: 11/17/2022]
|
3
|
Yoshii Y, Teramura S, Oyama K, Ogawa T, Hara Y, Ishii T. Development of three-dimensional preoperative planning system for the osteosynthesis of distal humerus fractures. Biomed Eng Online 2020; 19:56. [PMID: 32660498 PMCID: PMC7359224 DOI: 10.1186/s12938-020-00801-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Accepted: 07/04/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To reproduce anatomical reduction and appropriate implant placement/choices during osteosynthesis for elbow fractures, we developed a 3D preoperative planning system. To assess the utility of 3D digital preoperative planning for the osteosynthesis of distal humerus fractures, we evaluated the reproducibility of implant reduction shapes and placements in patients with distal humerus fractures. METHODS Twelve patients with distal humerus fractures who underwent osteosynthesis using 3D preoperative planning were evaluated. Reduction shapes were evaluated by the angle between the diaphysis axis and a line connecting the vertices of the medial epicondyle and the lateral epicondyle (epicondyle angle), and the angle between the diaphysis axis and the articular surface (joint angle) in the coronal plane, and the distance between the anterior diaphysis and the anterior articular surface in the sagittal plane (anterior distance) based on 3D images of the distal humerus. In addition, the implant positions were evaluated by the positions of the proximal and posterior edge of the plate, and the angle of the plate to the epicondyle line. The reproducibility was evaluated by intra-class correlation coefficients of the parameters between pre- and postoperative images. RESULTS The intra-class correlation coefficients were 0.545, 0.802, and 0.372 for the epicondyle angle, joint angle, and anterior distance, respectively. The differences in the measurements between the preoperative plan and postoperative reduction were 2.1 ± 2.1 degrees, 2.3 ± 1.8 degrees, and 2.8 ± 2.0 mm, for the epicondyle angle, joint angle, and anterior distance, respectively. The intra-class correlation coefficients were 0.983, 0.661, and 0.653 for the proximal and posterior plate positions, and the angle to the epicondyle, respectively. The differences in the measurements between the preoperative plan and postoperative reduction were 3.3 ± 2.1 mm, 2.7 ± 1.7 mm and 9.7 ± 9.8 degrees, for the plate positions of proximal and posterior edge, and the angle of the plate to the epicondyle line, respectively. There were significant correlations for the epicondyle angle, joint angle, and plate positions. CONCLUSIONS 3D preoperative planning for osteosynthesis of distal humerus fracture was reproducible for the reduction shape of the coronal view and the plate positions. It may be helpful for acquiring practical images of osteosynthesis in distal humerus fractures. LEVEL OF EVIDENCE Level III, a case-control study.
Collapse
Affiliation(s)
- Yuichi Yoshii
- Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, 3-20-1 Chuo, Ami, Inashiki, Ibaraki, 300-0395, Japan.
| | - Shin Teramura
- Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, 3-20-1 Chuo, Ami, Inashiki, Ibaraki, 300-0395, Japan
| | - Kazuki Oyama
- Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, 3-20-1 Chuo, Ami, Inashiki, Ibaraki, 300-0395, Japan
| | - Takeshi Ogawa
- Department of Orthopaedic Surgery, University of Tsukuba Hospital, Tsukuba, Ibaraki, 305-8576, Japan
| | - Yuki Hara
- Department of Orthopaedic Surgery, University of Tsukuba Hospital, Tsukuba, Ibaraki, 305-8576, Japan
| | - Tomoo Ishii
- Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, 3-20-1 Chuo, Ami, Inashiki, Ibaraki, 300-0395, Japan
| |
Collapse
|
4
|
Overeem SP, Goudeketting SR, Schuurmann RC, Heyligers JM, Verhagen HJ, Versluis M, de Vries JPP. Assessment of changes in stent graft geometry after chimney endovascular aneurysm sealing. J Vasc Surg 2019; 70:1754-1764. [DOI: 10.1016/j.jvs.2019.02.058] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2018] [Accepted: 02/19/2019] [Indexed: 11/24/2022]
|
5
|
van Schaik TG, Meekel JP, Jongkind V, Lely RJ, Truijers M, Hoksbergen AWJ, Wisselink W, Blankensteijn JD, Yeung KK. Secondary Fill Minimizes Gutter Size in Chimney EVAS Configurations In Vitro. J Endovasc Ther 2018; 26:62-71. [PMID: 30572773 PMCID: PMC6330694 DOI: 10.1177/1526602818819494] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Purpose: To investigate in an in vitro model if secondary endobag filling can reduce gutter size during chimney endovascular aneurysm sealing (chEVAS). Materials and Methods: Nellix EVAS systems were deployed in 2 silicone juxtarenal aneurysm models with suprarenal aortic diameters of 19 and 24 mm. Four configurations were tested: EVAS with 6-mm balloon-expandable (BE) or self-expanding (SE) chimney grafts (CGs) in the renal branches of both models. Balloons were inflated simultaneously in the CGs and main endografts during primary and secondary endobag filling and polymer curing. Computed tomography (CT) was performed immediately after the primary and secondary fills. Cross-sectional lumen areas were measured on the CT images to calculate gutter volumes and percent change. CG compression was calculated as the reduction in lumen surface area measured perpendicular to the central lumen line. The largest gutter volume and highest compression were presented per CG configuration per model. Results: Secondary endobag filling reduced the largest gutter volumes from 99.4 to 73.1 mm3 (13.2% change) and 84.2 to 72.0 mm3 (27.6% change) in the BECG configurations and from 67.2 to 44.0 mm3 (34.5% change) and 92.7 to 82.3 mm3 (11.2% change) in the SECG configurations in the 19- and 24-mm models, respectively. Secondary endobag filling increased CG compression in 6 of 8 configurations. BECG compression changed by −0.2% and 5.4% and by −1.0% and 0.4% in the 19- and 24-mm models, respectively. SECG compression changed by 10.2% and 16.0% and by 7.2% and 7.3% in the 19- and 24-mm models, respectively. Conclusion: Secondary endobag filling reduced paragraft gutters; however, this technique did not obliterate them. Increased CG compression and prolonged renal ischemia time should be considered if secondary endobag filling is used.
Collapse
Affiliation(s)
- Theodorus G van Schaik
- 1 Department of Vascular Surgery, VU University Medical Center, Amsterdam, the Netherlands
| | - Jorn P Meekel
- 1 Department of Vascular Surgery, VU University Medical Center, Amsterdam, the Netherlands
| | - Vincent Jongkind
- 3 Department of Surgery, Westfriesgasthuis, Hoorn, the Netherlands
| | - Rutger J Lely
- 2 Department of Interventional Radiology, VU University Medical Center, Amsterdam, the Netherlands
| | - Maarten Truijers
- 1 Department of Vascular Surgery, VU University Medical Center, Amsterdam, the Netherlands
| | - Arjan W J Hoksbergen
- 1 Department of Vascular Surgery, VU University Medical Center, Amsterdam, the Netherlands
| | - Willem Wisselink
- 1 Department of Vascular Surgery, VU University Medical Center, Amsterdam, the Netherlands
| | - Jan D Blankensteijn
- 1 Department of Vascular Surgery, VU University Medical Center, Amsterdam, the Netherlands
| | - Kak Khee Yeung
- 1 Department of Vascular Surgery, VU University Medical Center, Amsterdam, the Netherlands
| |
Collapse
|
6
|
van Noort K, Boersen JT, Zoethout AC, Schuurmann RCL, Heyligers JMM, Reijnen MMPJ, Zeebregts CJ, Slump CH, de Vries JPPM. Anatomical Predictors of Endoleaks or Migration After Endovascular Aneurysm Sealing. J Endovasc Ther 2018; 25:719-725. [DOI: 10.1177/1526602818808296] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose: To identify preoperative anatomical aortic characteristics that predict seal failures after endovascular aneurysm sealing (EVAS) and compare the incidence of events experienced by patients treated within vs outside the instructions for use (IFU). Methods: Of 355 patients treated with the Nellix EndoVascular Aneurysm Sealing System (generation 3SQ+) at 3 high-volume centers from March 2013 to December 2015, 94 patients were excluded, leaving 261 patients (mean age 76±8 years; 229 men) for regression analysis. Of these, 83 (31.8%) suffered one or more of the following events: distal migration ⩾5 mm of one or both stent frames, any endoleak, and/or aneurysm growth >5 mm. Anatomical characteristics were determined on preoperative computed tomography (CT) scans. Patients were divided into 3 groups: treated within the original IFU (n=166), outside the original IFU (n=95), and within the 2016 revised IFU (n=46). Categorical data are presented as the median (interquartile range Q1, Q3). Results: Neck diameter was significantly larger in the any-event cohort vs the control cohort [23.7 mm (21.7, 26.3) vs 23.0 mm (20.9, 25.2) mm, p=0.022]. Neck length was significantly shorter in the any-event cohort [15.0 mm (10.0, 22.5) vs 19.0 mm (10.0, 21.8), p=0.006]. Maximum abdominal aortic aneurysm (AAA) diameter and the ratio between the maximum AAA diameter and lumen diameter in the any-event group were significantly larger than the control group (p=0.041 and p=0.002, respectively). Regression analysis showed aortic neck diameter (p=0.006), neck length (p=0.001), and the diameter ratio (p=0.011) as significant predictors of any event. In the comparison of events to IFU status, 52 (31.3%) of 166 patients in the inside the original IFU group suffered an event compared to 13 (28.3%) of 46 patients inside the 2016 IFU group (p=0.690). Conclusion: Large neck diameter, short aortic neck length, and the ratio between the maximum AAA and lumen diameters are preoperative anatomical predictors of the occurrence of migration (⩾5 mm), any endoleak, and/or aneurysm growth (>5 mm) after EVAS. Even under the refined 2016 IFU, more than a quarter of patients suffered from an event. Improvements in the device seem to be necessary before this technique can be implemented on a large scale in endovascular AAA repair.
Collapse
Affiliation(s)
- Kim van Noort
- Department of Vascular Surgery, St Antonius Hospital, Nieuwegein, the Netherlands
- MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - Johannes T. Boersen
- Department of Vascular Surgery, St Antonius Hospital, Nieuwegein, the Netherlands
- MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - Aleksandra C. Zoethout
- Department of Vascular Surgery, Rijnstate Hospital, Arnhem, the Netherlands
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, the Netherlands
| | - Richte C. L. Schuurmann
- Department of Vascular Surgery, St Antonius Hospital, Nieuwegein, the Netherlands
- MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - Jan M. M. Heyligers
- Department of Vascular Surgery, Elisabeth-TweeSteden Hospital, Tilburg, the Netherlands
| | | | - Clark J. Zeebregts
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, the Netherlands
| | - Cornelis H. Slump
- MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - Jean-Paul P. M. de Vries
- Department of Vascular Surgery, St Antonius Hospital, Nieuwegein, the Netherlands
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, the Netherlands
| | | |
Collapse
|