Dueppers P, D’Oria M, Lepidi S, Calvagna C, Zimmermann A, Kopp R. An Expert-Based Review on the Relevance and Management of Type 2 Endoleaks Following Endovascular Repair of Ruptured Abdominal Aortic Aneurysms. J Clin Med 2024; 13:4300. [PMID: 39124566 PMCID: PMC11312779 DOI: 10.3390/jcm13154300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 07/18/2024] [Accepted: 07/20/2024] [Indexed: 08/12/2024] Open
Abstract
Ruptured abdominal aortic aneurysms (rAAAs) are life-threatening and require emergent surgical therapy. Endovascular aortic repair for rupture (rEVAR) has become the leading strategy due to its minimal invasive approach with expected lower morbidity and mortality, especially in patients presenting with hemodynamic instability and relevant comorbidities. Following rEVAR, intraoperative angiography or early postinterventional computed tomography angiography have to exclude early type 1 or 3 endoleaks requiring immediate reintervention. Persistent type 2 endoleaks (T2ELs) after rEVAR, in contrast to elective cases, can cause possibly lethal situations due to continuing extravascular blood loss through the remaining aortic aneurysm rupture site. Therefore, early identification of relevant persistent T2ELs associated with continuous bleeding and hemodynamic instability and immediate management is mandatory in the acute postoperative setting following rEVAR. Different techniques and concepts for the occlusion of T2ELs after rEVAR are available, and most of them are also used for relevant T2ELs after elective EVAR. In addition to various interventional embolization procedures for persistent T2ELs, some patients require open surgical occlusion of T2EL-feeding arteries, abdominal compartment decompression or direct surgical patch occlusion of the aneurysm rupture site after rEVAR. So far, in the acute situation of rAAAs, indications for preemptive or intraoperative T2EL embolization during rEVAR have not been established. In the long term, persistent T2ELs after rEVAR can lead to continuous aneurysm expansion with the possible development of secondary proximal type I endoleaks and an increased risk of re-rupture requiring regular follow-up and early consideration for reintervention. To date, only very few studies have investigated T2ELs after rEVAR or compared outcomes with those from elective EVAR regarding the special aspects of persisting T2ELs. This narrative review is intended to present the current knowledge on the incidence, natural history, relevance and strategies for T2EL management after rEVAR.
Collapse
Affiliation(s)
- Philip Dueppers
- Department of Vascular Surgery, University of Zurich (UZH), Raemistrasse 100, CH-8008 Zurich, Switzerland; (A.Z.); (R.K.)
- Department of Vascular Surgery, Kantonsspital St. Gallen, CH-9000 St. Gallen, Switzerland
| | - Mario D’Oria
- Division of Vascular and Endovascular Surgery, Department of Clinical Surgical and Health Sciences, University of Trieste, 34149 Trieste, Italy; (M.D.); (S.L.); (C.C.)
| | - Sandro Lepidi
- Division of Vascular and Endovascular Surgery, Department of Clinical Surgical and Health Sciences, University of Trieste, 34149 Trieste, Italy; (M.D.); (S.L.); (C.C.)
| | - Cristiano Calvagna
- Division of Vascular and Endovascular Surgery, Department of Clinical Surgical and Health Sciences, University of Trieste, 34149 Trieste, Italy; (M.D.); (S.L.); (C.C.)
| | - Alexander Zimmermann
- Department of Vascular Surgery, University of Zurich (UZH), Raemistrasse 100, CH-8008 Zurich, Switzerland; (A.Z.); (R.K.)
| | - Reinhard Kopp
- Department of Vascular Surgery, University of Zurich (UZH), Raemistrasse 100, CH-8008 Zurich, Switzerland; (A.Z.); (R.K.)
- Department of Vascular and Endovascular Surgery, University Hospital Regensburg, University of Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
2
|
Piazza M, Squizzato F, Pratesi G, Parlani G, Simonte G, Giudice R, Mansour W, Veraldi GF, Gennai S, Antonello M. Editor's Choice - Outcomes of Off the Shelf Outer Branched Versus Inner Branched Endografts in the Treatment of Thoraco-Abdominal Aortic Aneurysm in the B.R.I.O. (BRanched Inner - Outer) Study Group. Eur J Vasc Endovasc Surg 2024; 68:50-59. [PMID: 38636923 DOI: 10.1016/j.ejvs.2024.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/25/2024] [Accepted: 04/10/2024] [Indexed: 04/20/2024]
Abstract
OBJECTIVE This study aimed to compare two commercially available off the shelf branched endografts for thoraco-abdominal aortic aneurysm (TAAA) repair, namely the E-nside (Artivion) and Zenith t-Branch (Cook Medical) devices. METHODS This multicentre retrospective study (2020 - 2023) included patients treated by branched endovascular aortic repair (BEVAR) for TAAA using the inner branched E-nside or the outer branched t-Branch. Endpoints were 30 day technical success and major adverse events (MAEs) as well as one year freedom from target vessel instability and main endograft instability. RESULTS The study included 163 patients: 79 (307 target vessels) treated with E-nside and 84 (325 target vessels) with t-branch. Aneurysm extent was I - III in 91 patients (55.8%; 47% of E-nside and 66% of t-Branch) and IV in 72 patients (44.2%; 53% of E-nside and 34% of t-Branch) (p = .011). An adjunctive proximal thoracic endograft was used in 43% of E-nside vs. 69% of t-Branch (p < .001), with less frequent thoracic endografting (14% vs. 76%; p < .001) and shorter length of coverage (p = .024) in extent IV TAAA treated by E-nside. E-nside cases had shorter renal artery bridging lengths (66 ± 17 mm vs. 76 ± 20 mm; p < .010) and less frequent use of a distal bifurcated endograft (53% vs. 80%; p < .001). Comparing 30 day results, the mortality rate was 1% vs. 2% (p = .62), any MAE occurred in 18% vs. 21% (p = .55), the stroke rate was 3% vs. 0% (p = .23), and the elective spinal cord ischaemia rate was 5% vs. 8% (p = .40) for E-nside and t-Branch, respectively. At one year, freedom from target vessel instability was 96 ± 3% for E-nside and 95 ± 3% for t-Branch (p = .58), and freedom from endograft instability was 98 ± 2% vs. 97 ± 3% (p = .46), respectively. CONCLUSION Both off the shelf devices provided excellent early and one year results. The E-nside may require shorter thoracic aortic coverage and bridging length for the renal arteries, and less frequent implantation of a concomitant proximal thoracic or distal abdominal bifurcated endograft. However, these aspects did not determine significant differences in clinical outcomes.
Collapse
Affiliation(s)
- Michele Piazza
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
| | - Francesco Squizzato
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy. https://www.twitter.com/dr_fsquizzato
| | - Giovanni Pratesi
- Vascular and Endovascular Surgery Unit, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
| | - Gianbattista Parlani
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy
| | - Gioele Simonte
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy
| | - Rocco Giudice
- Vascular and Endovascular Surgery Unit, San Giovanni Addolorata Hospital, Rome, Italy
| | - Wassim Mansour
- Vascular Surgery Division, Department of Surgery "Paride Stefanini", Policlinico Umberto I -"La Sapienza" University of Rome, Rome, Italy
| | | | - Stefano Gennai
- Division of Vascular Surgery, University Hospital of Modena and Reggio Emilia, Baggiovara (MO), Italy
| | - Michele Antonello
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| |
Collapse
|
3
|
Piazza M, Squizzato F, Ferri M, Pratesi G, Gatta E, Orrico M, Giudice R, Antonello M. Outcomes of off-the-shelf preloaded inner branch device for urgent endovascular thoraco-abdominal aortic repair in the ItaliaN Branched Registry of E-nside EnDograft. J Vasc Surg 2024:S0741-5214(24)01235-7. [PMID: 38908806 DOI: 10.1016/j.jvs.2024.05.056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 05/21/2024] [Accepted: 05/28/2024] [Indexed: 06/24/2024]
Abstract
OBJECTIVE The aim of this study was to report the outcomes of endovascular urgent thoracoabdominal aortic (TAAA) repair, using an off-the-shelf preloaded inner branch device (E-nside; Artivion). METHODS Data from a physician-initiated national multicenter registry, including patients treated with E-nside endograft (INBREED) were prospectively collected (2020-2024); only urgent cases were included in this study. Primary outcomes were technical success and mortality at 30 days. Secondary outcomes were spinal cord ischemia rate, stroke rate, major adverse events (MAE) as also branch instability at 12 months. RESULTS Of 185 patients enrolled in the INBREED, 64 (34.5%) were treated in a urgent setting and were included in the study. Reason for urgent repair was presence of aneurysm-related symptoms in 31 patients (48.4%), a contained rupture in eight (12.5%), and a large aneurysm >80 mm in 25 (39.1%). Extent of repair was I to III in 32 patients (50%) and IV in 32 (50%); 18 (28%) had a narrow (<25 mm) paravisceral aortic lumen. An adjunctive proximal thoracic endograft was deployed in 29 patients (45.3%); a distal bifurcated abdominal endograft was used in 33 (51.5%). Two hundred forty-nine target vessels (97.2%) were successfully incorporated through an inner branch from an upper arm (81.2%) or femoral (18.8%) access. A balloon expandable stent was used in 184 (75.7%) target vessels, a self-expandable stent in 59 (24.3%). Mean time for target vessel bridging was 39.9 ± 28.4 minutes per target vessel. Thirty-day cumulative major adverse event (MAE) rate was 28%, and mortality occurred in five patients (9.1%). There was one postoperative stroke (1.6%), and the spinal cord ischemia (SCI) rate was 8% (n = 5). For the 249 target vessels successfully incorporated through an inner branch, 1-year freedom from target vessel instability was 93% ± 3% after 1 year. CONCLUSIONS The E-nside represents a valid solution for the urgent treatment of TAAAs, including symptomatic and ruptured TAAAs, as well as large asymptomatic TAAAs that cannot wait for a custom-made device. The preloaded inner branches and available proximal and distal graft diameters might be useful in urgent settings and provided satisfactory early and 1-year results, in terms of both endograft and target vessel stability. Further studies are required to assess the clinical role of E-nside for urgent TAAA repair.
Collapse
Affiliation(s)
- Michele Piazza
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
| | - Francesco Squizzato
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Michelangelo Ferri
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Giovanni Pratesi
- Vascular and Endovascular Surgery Unit, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
| | - Emanuele Gatta
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, Ancona, Italy
| | - Matteo Orrico
- Department of Vascular Surgery, Ospedale San Camillo-Forlanini, Rome, Italy
| | - Rocco Giudice
- Vascular and Endovascular Surgery Unit, San Giovanni Addolorata Hospital, Rome, Italy
| | - Michele Antonello
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| |
Collapse
|
4
|
Simonte G, Gatta E, Vento V, Parlani G, Simonte R, Montecchiani L, Isernia G. Partial Deployment to Save Space for Vessel Cannulation When Treating Complex Aortic Aneurysms with Narrow Paravisceral Lumen Is Also Feasible Using Inner-Branched Pre-Cannulated Endografts. J Clin Med 2024; 13:3060. [PMID: 38892771 PMCID: PMC11172520 DOI: 10.3390/jcm13113060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 05/21/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024] Open
Abstract
Introduction: The aim of this paper is to propose a sequential deployment technique for the E-nside off-the-shelf endograft that could potentially enhance target visceral vessel (TVV) cannulation and overstenting in narrow aortic anatomies. Methods: All data regarding patients consecutively treated in two aortic centers with the E-nside graft employing the partial deployment technique were included in the study cohort and analyzed. To execute the procedure with partial endograft deployment, the device should be prepared before insertion by advancing, under fluoroscopy, all four dedicated 400 cm long 0.018″ non-hydrophilic guidewires until their proximal ends reach the cranial graft's edge. Anticipating this guidewire placement prevents the inability to do so once the endograft is partially released, avoiding potentially increased friction inside the constricted pre-loaded microchannels. The endograft is then advanced and deployed in the standard fashion, stopping just after the inner branch outlets are fully expanded. Tip capture is released, and the proximal end of the device is opened. Visceral vessel bridging is completed from an upper access in the desired sequence, and the graft is fully released after revascularizing one or more arteries. Preventing the distal edge of the graft from fully expanding improves visceral vessel cannulation and bridging component advancement, especially when dealing with restricted lumina. Results: A total of 26 patients were treated during the period December 2019-March 2024 with the described approach. Procedure was performed in urgent settings in 14/26 cases. The available lumen was narrower than 24 mm at the origin of at least one target vessel in 11 out of 26 cases performed (42.3%). Technical success was obtained in 24 out of 26 cases (92.3%), with failures being due to TVVs loss. No intraoperative death or surgical conversion was recorded, and no early reintervention was needed in the perioperative period. Clinical success at 30 days was therefore 80.7%. Conclusions: The described technique could be considered effective in saving space outside of the graft, allowing for safe navigation and target vessel cannulation in narrow visceral aortas, similar to what has already been reported for outer-branched endografts.
Collapse
Affiliation(s)
- Gioele Simonte
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Emanuele Gatta
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Vincenzo Vento
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Gianbattista Parlani
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Rachele Simonte
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Luca Montecchiani
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Giacomo Isernia
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| |
Collapse
|
5
|
Becker D, Sikman L, Ali A, Mosbahi S, F. Prendes C, Stana J, Tsilimparis N. Analysis of Target Vessel Instability in Fenestrated Endovascular Repair (f-EVAR) in Thoraco-Abdominal Aortic Pathologies. J Clin Med 2024; 13:2898. [PMID: 38792439 PMCID: PMC11122549 DOI: 10.3390/jcm13102898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 04/28/2024] [Accepted: 05/08/2024] [Indexed: 05/26/2024] Open
Abstract
Objective: The aim of this study was to evaluate the influence of target vessel anatomy and post-stenting geometry on the outcome of fenestrated endovascular aortic repair (f-EVAR). Methods: A retrospective review of data from a single center was conducted, including all consecutive fenestrated endovascular aortic repairs (f-EVARs) performed between September 2018 and December 2023 for thoraco-abdominal aortic aneurysms (TAAAs) and complex abdominal aortic aneurysms (cAAAs). The analysis focused on the correlation of target vessel instability to target vessel anatomy and geometry after stenting. The primary endpoint was the cumulative incidence of target vessel instability. Secondary endpoints were the 30-day and follow-up re-interventions. Results: A total of 136 patients underwent f-EVAR with 481 stented target vessels. A total of ten target vessel instabilities occurred including three in visceral and seven instabilities in renal vessels. The cumulative incidence of target vessel instability with death as the competing risk was 1.4%, 1.8% and 3.4% at 1, 2 and 3 years, respectively. In renal target vessels (260/481), a diameter ≤ 4 mm (OR 1.21, 95% CI 1.035-1.274, p = 0.009) and an aortic protrusion ≥ 5.75 mm (OR 8.21, 95% CI 3.150-12-23, p = 0.027) was associated with an increased target vessel instability. In visceral target vessels (221/481), instability was significantly associated with a preoperative tortuosity index ≥ 1.25 (HR 15.19, CI 95% 2.50-17.47, p = 0.045) and an oversizing ratio of ≥1.25 (HR 7.739, CI % 4.756-12.878, p = 0.049). Conclusions: f-EVAR showed favorable mid-term results concerning target vessel instability in the current cohort. A diameter of ≤4 mm and an aortic protrusion of ≥5.75 mm in the renal target vessels as well as a preoperative tortuosity index and an oversizing of the bridging stent of ≥1.25 in the visceral target vessels should be avoided.
Collapse
Affiliation(s)
- Daniel Becker
- Department of Vascular Surgery, University Hospital, LMU Munich, 81377 Munich, Germany; (D.B.); (L.S.); (A.A.); (C.F.P.); (J.S.)
| | - Laura Sikman
- Department of Vascular Surgery, University Hospital, LMU Munich, 81377 Munich, Germany; (D.B.); (L.S.); (A.A.); (C.F.P.); (J.S.)
| | - Ahmed Ali
- Department of Vascular Surgery, University Hospital, LMU Munich, 81377 Munich, Germany; (D.B.); (L.S.); (A.A.); (C.F.P.); (J.S.)
- Department of Vascular Surgery, Cardiovascular and Vascular Surgery Center, University Hospital, Mansoura University, Mansoura 35516, Egypt
| | - Selim Mosbahi
- Department of Cardiac Sugery, University Hospital, Inselspital Bern, 3010 Bern, Switzerland;
| | - Carlota F. Prendes
- Department of Vascular Surgery, University Hospital, LMU Munich, 81377 Munich, Germany; (D.B.); (L.S.); (A.A.); (C.F.P.); (J.S.)
| | - Jan Stana
- Department of Vascular Surgery, University Hospital, LMU Munich, 81377 Munich, Germany; (D.B.); (L.S.); (A.A.); (C.F.P.); (J.S.)
| | - Nikolaos Tsilimparis
- Department of Vascular Surgery, University Hospital, LMU Munich, 81377 Munich, Germany; (D.B.); (L.S.); (A.A.); (C.F.P.); (J.S.)
| |
Collapse
|
6
|
Zhang HP, Ge YY, Wang JB, Fan TT, Guo W. Off the Shelf Multibranched Endograft for Thoraco-Abdominal and Pararenal Abdominal Aortic Aneurysms: a Prospective, Single Centre Study of the G-Branch Endograft. Eur J Vasc Endovasc Surg 2024; 67:417-425. [PMID: 37926150 DOI: 10.1016/j.ejvs.2023.11.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 10/04/2023] [Accepted: 11/02/2023] [Indexed: 11/07/2023]
Abstract
OBJECTIVE To investigate outcomes of a novel, off the shelf multibranched endovascular stent graft for the treatment of thoraco-abdominal aortic aneurysm (TAAA) and pararenal abdominal aortic aneurysm (PAAA). METHODS A prospective, single centre study including 15 patients (mean age, 63.4 ± 10.7 years; 13 male) with TAAA or PAAA treated from October 2019 to March 2021 with a G-Branch endograft (Lifetech Scientific, Shenzhen, China) featuring a mixed multibranch design with two inner and two outer branches for reconstruction of the visceral and bilateral renal arteries, respectively. Follow up assessments were scheduled before discharge and at 30 days, six and 12 months after the index procedure. Annual telephone interviews were performed beyond the initial 12 months. The Kaplan-Meier method was used to estimate cumulative mortality and morbidity rates after endovascular repair. RESULTS Technical success was achieved in all 15 patients. Nine patients (60%) had TAAA and six (40%) had PAAA (mean maximum aneurysm diameter, 73.7 ± 15.8 mm). The median follow up was 31.4 months (range, 10.1 - 44.0 months). At 30 days, there was no death and 7% morbidity (one case of temporary spinal cord ischaemia on Day 4). At one year, the mortality rate was 7% (one death from stroke at 10 months) and morbidity was 13% (one other case of renal function decline at six months). There were no aneurysm dilatations, re-interventions, or access related complications, and two (13%) persistent type II endoleaks. The one year primary branch patency rate was 100% for the four renovisceral arteries in all 13 patients who underwent computed tomography examinations. One patient died of hepatocellular carcinoma 29 months post-operatively, resulting in an estimated three year mortality rate of 13%. CONCLUSION The G-Branch endograft yielded high technical success with good early and midterm outcomes for the treatment of TAAA and PAAA. A large multicentre study is warranted.
Collapse
Affiliation(s)
- Hong P Zhang
- Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Yang Y Ge
- Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Jia B Wang
- Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Ting T Fan
- Department of Biomechanics and Rehabilitation Engineering, School of Biomedical Engineering, Capital Medical University, Beijing, China
| | - Wei Guo
- Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China.
| |
Collapse
|
7
|
Grima MJ, Wanhainen A, Lindström D. In Situ Laser Fenestration Technique: Bench-Testing of Aortic Endograft to Guide Clinical Practice. J Endovasc Ther 2024; 31:126-131. [PMID: 36000361 PMCID: PMC10773159 DOI: 10.1177/15266028221119315] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE In situ laser fenestration (ISLF) is a recently introduced technology that offers the potential to perform total endovascular treatment of aortic arch and thoracoabdominal aortic pathologies in the acute setting. This experiment's aim was to assess ISLF in some currently common aortic endografts and bridging stent-grafts. MATERIALS AND METHODS Three different aortic endografts were evaluated: (1) Zenith Alpha, (2) Zenith TX2, and (3) Conformable GORE TAG. Each endograft was submerged in 37°C saline to create fenestrations using the 308 nm CVX-300 Excimer Laser System fitted with a 2.3 mm diameter Turbo-Elite laser atherectomy catheter compatible with a 0.018″ guidewire. Three different 8 mm bridging stent-grafts were evaluated: (1) BeGraft peripheral, (2) BeGraft peripheral plus, and (3) GORE VIABAHN VBX Balloon Expandable. All bridging stent-grafts were deployed and exposed to different balloon sizes and pressures. The ISLFs and bridging stent-grafts were then evaluated for any tears, stenoses, and seal. RESULTS A laser fenestration was consistently rapidly obtained in the Zenith Alpha and the Zenith TX2 endografts while it proved difficult to achieve a timely fenestration in the C-TAG. No fabric tears were noted in the Zenith Alpha and Zenith TX2 when inflating Armada (Abbott) 8 mm balloon in the fenestrations with pressures up to 15 atmospheres (rated burst pressure) nor when flaring bridging stent-grafts with balloons up to 12 mm in diameter at 10 atmospheres, while major tears were frequently noted in the C-TAG when the Armada 8 mm balloons were inflated. BeGraft Peripheral and BeGraft Peripheral Plus were all firmly attached to the fenestrations showing good seal on manual testing, while every sixth VBX bridging stent-graft displayed poorer attachment to the fenestration before dilatation at high pressure. Commonly, significant stenoses remained in the bridging stent-grafts after dilatation at nominal pressure, which could only be eradicated with high-pressure balloons. CONCLUSION In this limited bench-test, Dacron endografts responded well to the ISLF technology. Satisfactory deployment of the bridging stent was noted only after inflation and/or flaring with high-pressure balloons. Further work with different types of commercially-available bridging stent-grafts and endografts to assess the durability of in situ fenestration (ISF) and bridging stents in ISF is recommended. CLINICAL IMPACT This report on experimental in situ laser fenestration provide important insights for clinicians considering using in situ laser fenestration of aortic stentgrafts in vivo. In particular, different laser settings were tested together with a selection of aortic stentgrafts. Also, the target pressure needed in PTA balloons to dilate the fenestrations and any subsequent tears in the fabric were noted. This was followed by deployment of assorted balloon-expandable stentgrafts with estimation of residual stenosis and seal.
Collapse
Affiliation(s)
- Matthew Joe Grima
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden
- Faculty of Medicine and Surgery, University of Malta, L-iMsida, Malta
- Department of General Surgery, Vascular Unit, Mater Dei Hospital, L-iMsida, Malta
| | - Anders Wanhainen
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden
- Department of Surgical and Perioperative Sciences, Surgery, Umeå University, Umeå, Sweden
| | - David Lindström
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden
| |
Collapse
|
8
|
Gao JP, Zhang HP, Xiong J, Jia X, Ma XH, Wang LJ, Xu YL, Zhang MH, Guo W. First-in-Human Clinical Trial of the WeFlow-JAAA Endograft System in Patients With Juxtarenal Abdominal Aortic Aneurysms. J Endovasc Ther 2023:15266028231210480. [PMID: 37997684 DOI: 10.1177/15266028231210480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2023]
Abstract
OBJECTIVE To preliminarily evaluate the safety and efficacy of the WeFlow-JAAA endograft, a novel off-the-shelf device designed for the repair of juxtarenal abdominal aortic aneurysms (JRAAAs) and pararenal abdominal aortic aneurysms (PRAAAs). METHODS This prospective single-arm first-in-human clinical trial included patients with JRAAAs (infrarenal necks ≤10 mm) or PRAAAs with at least a 5 mm sealing zone below the superior mesenteric artery (SMA) who underwent endovascular repair using the WeFlow-JAAA endograft system. With this system, the celiac artery was addressed with a wide scallop, the renal arteries (RAs) were addressed with 2 standard inner branches, and the SMA was addressed with a "mini-inner-cuff" reinforced fenestration. The primary efficacy endpoint was the clinical success at 12 months. The primary safety endpoint was the freedom from major adverse events (MAEs) in the first 30 days after surgery. RESULTS Fifteen patients (all men; mean age 68.5±6.0 years) were enrolled between October 2019 and August 2021. The median infrarenal neck length was 0 mm (IQR, 0-4 mm). Technical success was achieved in all patients. No MAEs occurred in the first 30 days. The mean fluoroscopy time was 73.1±27.8 minutes, and the mean volume of contrast media was 130.7±29.4 mL. Clinical success was maintained in all patients at 12 months. No aortic-related deaths, aneurysm rupture, type I or type III endoleak, or open surgery conversion occurred during the follow-up period. The secondary intervention was required only in 1 patient who developed an occluded right RA stent 14 months after the procedure. CONCLUSION The WeFlow-JAAA endograft device appears to be safe and efficacious in selected patients with JRAAAs or PRAAAs with more than 5 mm sealing zone below SMA. Large-scale, multicenter, and prospective studies with long-term follow-ups are ongoing to validate our findings in China. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT04745546 (URL: Guo's Visceral Arteries Reconstruction: The First in Man Study of WeFlow-JAAA Stent Graft System-Full-Text View-ClinicalTrials.gov). CLINICAL IMPACT The first-in-human clinical trial of the WeFlow-JAAA endograft system demonstrates promising safety and efficacy in treating juxtarenal abdominal aortic aneurysms (JRAAAs) and partial pararenal abdominal aortic aneurysms (PRAAAs). This innovative off-the-shelf device offers a potential alternative to traditional endovascular aortic repair. The successful outcomes, including technical success in all patients, freedom from major adverse events, and maintenance of clinical success at 12 months, suggest a potential shift in clinical practice towards using the WeFlow-JAAA endograft system for selected patients. This study paves the way for larger-scale, multicenter, prospective studies to further validate its long-term safety and efficacy, offering clinicians a new option for managing complex abdominal aortic aneurysms.
Collapse
Affiliation(s)
- Jiang-Ping Gao
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Hong-Peng Zhang
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Jiang Xiong
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Xin Jia
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Xiao-Hui Ma
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Li-Jun Wang
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Yong-Le Xu
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Min-Hong Zhang
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Wei Guo
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
9
|
Bilman V, Rinaldi E, Loschi D, Sheick-Yousif B, Melissano G. Suitability of current off-the-shelf devices for endovascular TAAA repair: a systematic review. THE JOURNAL OF CARDIOVASCULAR SURGERY 2023; 64:459-469. [PMID: 37199677 DOI: 10.23736/s0021-9509.23.12704-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
INTRODUCTION The aim of the present study is to perform a systematic review of published papers regarding the suitability of the current off-the-shelf (OTS) devices for endovascular thoracoabdominal aortic aneurysm (TAAA) repair. EVIDENCE ACQUISITION A systematic review of the MEDLINE database via PubMed was performed in March 2023. All studies reporting the outcomes of the three currently available OTS stent-grafts: the Zenith t-Branch (Cook Medical, Bloomington, IN, USA), the Gore Excluder thoracoabdominal branch endoprosthesis (TAMBE; W.L. Gore & Associates, Flagstaff, AZ, USA) and the E-nside Multibranch Stent-Graft System (Artivion, Kennesaw, GA, USA), were retrieved and further analyzed. The main endpoints were technical success, reintervention rate, and primary branch patency. Theoretical feasibility studies of these OTS devices were also included and separately analyzed. EVIDENCE SYNTHESIS A total of 19 studies were published between 2014 and 2023. Thirteen clinical studies and six theoretical feasibility studies were included. Eleven studies reported the clinical outcomes of the t-Branch stent-graft, one detailed the observational results of the use of the E-nside endoprosthesis, and one described the TAMBE stent-graft results. The following data primarily involve the t-Branch device outcomes. A total of 1131 patients that underwent aneurysm repair using an OTS stent-graft were identified. Among those, 1002, 116 and 13 patients received a t-Branch, E-nside, and TAMBE stent-grafts, respectively. A total of 767 (67.8%) were men, with a mean age of 71.6±7.4 years old, and a mean Body Mass Index (BMI) of 26.3±3.8 kg/m2. Technical success ranged from 64% to 100%. A total of 4172 target visceral vessels (TVV) were planned for bridging, with a success rate ranging from 92 to 100%. The total of early and late reinterventions reported were 64 and 48, respectively, mainly due to endoleaks and visceral branch occlusions. Among the theoretical feasibility studies, six described the feasibility of the t-Branch device in a total of 661 patients, two described the E-nside and the TAMBE devices feasibility comprising 351 patients for each stent-graft. The overall feasibility of the t-Branch device varied from 39% to 88%, the E-nside from 43% to 75%, and the TAMBE stent-graft ranged from 33% to 94%. CONCLUSIONS This systematic review demonstrated a good suitability for the use of OTS endografts for the treatment of TAAA.
Collapse
Affiliation(s)
- Victor Bilman
- Department of Vascular Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Enrico Rinaldi
- Department of Vascular Surgery, Vita-Salute San Raffaele University School of Medicine, IRCCS San Raffaele Hospital, Milan, Italy
| | - Diletta Loschi
- Department of Vascular Surgery, Vita-Salute San Raffaele University School of Medicine, IRCCS San Raffaele Hospital, Milan, Italy
| | - Basheer Sheick-Yousif
- Department of Vascular Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Germano Melissano
- Department of Vascular Surgery, Vita-Salute San Raffaele University School of Medicine, IRCCS San Raffaele Hospital, Milan, Italy -
| |
Collapse
|
10
|
Melloni A, Bertoglio L, Van den Eynde W, Agrusa CJ, Parlani G, Howard DPJ, Rio J, Fazzini S, Mansour W, Dias NV, Ronchey S, Branzan D. Outcomes of Percutaneous Access to the First Versus Third Segment of Axillary Artery During Aortic Procedures. J Endovasc Ther 2023:15266028231202456. [PMID: 37750487 DOI: 10.1177/15266028231202456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
PURPOSE This article aims at investigating the outcomes of percutaneous access via the first versus third axillary artery (AXA) segments with closure devices during aortic procedures. MATERIALS AND METHODS All patients receiving percutaneous AXA access closed with Perclose ProGlide device (Abbott, Santa Clara, California) from 2008 to 2021 were included in a retrospective multicenter registry (NCT: 04589962). Efficacy endpoint was the technically successful percutaneous procedure (no open conversion). Safety endpoints were stroke and access complications according to the Valve Academic Research Consortium-3 reporting standards. The first (AXA1) or third (AXA3) axillary puncture sites were compared. RESULTS A total of 412 percutaneous AXA accesses were included: 172 (42%) in AXA1 and 240 (58%) in AXA3. Left AXA was catheterized in 363 cases (76% of AXA1 vs 97% of AXA3, p<0.001) and 91% of fenestrated/branched endovascular repair (F/BEVAR) procedures were conducted from the left. A ≥12F internal diameter (ID) sheath was used in 49% of procedures. Open conversion rate was 1%, no major vascular complications occurred, and only one major non-vascular complication was recorded. Primary closure failure occurred in 18 AXA1 (11%) and 32 AXA3 accesses (13%), treated by covered (8.3%) or bare-metal (2.7%) stenting. Bailout stent patency was 100% at median follow-up of 12 months, with 6 of 6 stents still patent after >36 months of follow-up. Stroke rate was 4.4%. An introducer sheath >12F was independently associated with both access complications (p<0.001) and stroke (p=0.005), while a right-side access was associated with stroke only (p=0.034). Even after adjustment for covariates, AXA1 versus AXA3 showed an equal success rate (odds ratio [OR]=0.537, 95% confidence interval [CI]=0.011-1.22 for AXA3, p=0.104). The combination of AXA3 and a >10F introducer sheath provided worse outcomes compared with >10F sheaths through AXA1 (OR for success=0.367, 95% CI=0.176-0.767, p=0.008). This was not confirmed for >12F sheaths, associated with similar outcomes (p=0.31 AXA 1 vs AXA 3). CONCLUSION Major local complications with the percutaneous axillary approach and ≤12F sheaths are infrequent and solvable by complementary endovascular interventions. Stroke risk remains an issue. First and third AXA segments are both amenable for access with good results, but larger sheaths (12F) perform better in AXA1. CLINICAL IMPACT Percutaneous access with vascular closure devices at the first or third axillary artery (AXA) segments during aortic procedures is burdened by a negligible risk of open conversion. Local complications with the percutaneous axillary approach are infrequent and solvable by complementary endovascular interventions. First and third AXA segments are both amenable to access with excellent results, but larger sheaths (12F) perform better in the wider first AXA segment. In this setting, bailout stenting does not appear to be associated with mid-term stent occlusion.
Collapse
Affiliation(s)
- Andrea Melloni
- Division of Vascular Surgery, Vita-Salute San Raffaele University, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Luca Bertoglio
- Division of Vascular Surgery, Vita-Salute San Raffaele University, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Wouter Van den Eynde
- Department of Vascular and Thoracic Surgery, Imelda Hospital, Bonheiden, Belgium
| | - Christopher J Agrusa
- Division of Vascular Surgery, New York-Presbyterian Hospital/Weill Cornell Medical Center, New York, NY, USA
| | - Gianbattista Parlani
- Vascular and Endovascular Surgery Unit, S. Maria Misericordia Hospital, University of Perugia, Perugia, Italy
| | - Dominic P J Howard
- Department of Vascular Surgery, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Javier Rio
- Servicio de Angiología y Cirugía Vascular, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Stefano Fazzini
- Vascular Surgery Unit, Biomedicine and Prevention Department, University of Rome Tor Vergata, Rome, Italy
| | - Wassim Mansour
- Vascular and Endovascular Surgery Division, Department of Surgery "Paride Stefanini," Policlinico Umberto I, "Sapienza" University, Rome, Italy
| | - Nuno V Dias
- Department of Thoracic Surgery and Vascular Diseases, Vascular Centre, Skåne University Hospital, Malmö, Sweden
| | - Sonia Ronchey
- Department of Vascular Surgery, San Filippo Neri Hospital, Rome, Italy
| | - Daniela Branzan
- Department of Vascular Surgery, University Hospital Leipzig, and Helmholtz Institute for Metabolic, Obesity and Vascular Research (HI-MAG) of the Helmholtz Zentrum Munich at the University of Leipzig and University Hospital Leipzig, Leipzig, Germany
| |
Collapse
|
11
|
Benk J, Kreibich M, Berger T, Kondov S, Beyersdorf F, Czerny M, Rylski B. Branched endovascular iliac artery repair using the Zenith ® Branch Endovascular Iliac Bifurcation graft: outcomes and reinterventions in our retrospective cohort. Cardiovasc Diagn Ther 2023; 13:700-709. [PMID: 37675087 PMCID: PMC10478024 DOI: 10.21037/cdt-22-564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Accepted: 06/14/2023] [Indexed: 09/08/2023]
Abstract
Background The aim of this retrospective cohort study was to analyze the outcomes and the need for reinterventions following branched iliac artery repair using the Zenith® Branch Endovascular Iliac Bifurcation (ZBIS; Cook Medical Europe LTD, Limerick, Ireland) graft. Methods Patient characteristics and follow-up data on 63 patients following branched iliac artery repair using the ZBIS device were evaluated and compared between patients with and without iliac reinterventions. A competing risk regression model was analyzed to identify independent predictors of reinterventions, and to predict the reintervention risk. Results ZBIS implantation's technical success rate was 100%, and we observed no in-hospital mortality. Internal iliac artery patency was 93% during a median [first quartile, third quartile] follow-up of 19 [5, 39] months. Thirty-two iliac reinterventions were performed in 23 patients (37%) after a mean time of 3.0 months (IQR: 0.4-6.8) (time to first reintervention). Endoleaks type I and II were the most common indication for reinterventions (n=14, 61%). The internal iliac artery's diameter [subdistribution hazard ratio (sHR): 1.046; P=0.0015] and a prior abdominal aortic intervention (sHR: 0.3331; P=0.0370) were identified as significant variables in the competing risk regression model for a reintervention. The risk for reintervention was 33% (95% CI: 20-46%), and 46% (95% CI: 28-63%) after 12 and 36 months, respectively. Conclusions Endovascular repair of degenerative iliac artery aneurysms with Zenith Branch Iliac Bifurcation device is a feasible and safe option. Perioperative morbidity and mortality are low with good graft patency rates. The risk for secondary iliac artery interventions is considerable and highlights the need for patients with iliac disease to undergo continuous follow-up in a dedicated vascular center.
Collapse
Affiliation(s)
| | | | - Tim Berger
- Department of Cardiovascular Surgery, University Heart Center Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - Stoyan Kondov
- Department of Cardiovascular Surgery, University Heart Center Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - Friedhelm Beyersdorf
- Department of Cardiovascular Surgery, University Heart Center Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - Martin Czerny
- Department of Cardiovascular Surgery, University Heart Center Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - Bartosz Rylski
- Department of Cardiovascular Surgery, University Heart Center Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| |
Collapse
|
12
|
Kapalla M, Busch A, Lutz B, Nebelung H, Wolk S, Reeps C. Single-center initial experience with inner-branch complex EVAR in 44 patients. Front Cardiovasc Med 2023; 10:1188501. [PMID: 37396572 PMCID: PMC10309562 DOI: 10.3389/fcvm.2023.1188501] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 05/16/2023] [Indexed: 07/04/2023] Open
Abstract
Purpose The use of inner-branch aortic stent grafts in the treatment of complex aortic pathologies aims at broad applicability and stable bridging stent sealing compared to other endovascular technologies. The objective of this study was to evaluate the early outcomes with a single manufacturer custom-made and off-the-shelf inner-branched endograft in a mixed patient cohort. Methods This retrospective, monocentric study between 2019 and 2022 included 44 patients treated with inner-branched aortic stent grafts (iBEVAR) as custom-made device (CMD) or off-the-shelf device (E-nside) with at least four inner branches. The primary endpoints were technical and clinical success. Results Overall, 77% (n = 34) and 23% (n = 10) of the patients (mean age 77 ± 6.5 years, n = 36 male) were treated with a custom-made iBEVAR with at least four inner branches and an off-the-shelf graft, respectively. Treatment indications were thoracoabdominal pathologies in 52.2% (n = 23), complex abdominal aneurysms in 25% (n = 11), and type Ia endoleaks in 22.7% (n = 10). Preoperative spinal catheter placement was performed in 27% (n = 12) of patients. Implantation was entirely percutaneous in 75% (n = 33). Technical success was 100%. Target vessel success manifested at 99% (178/180). There was no in-hospital mortality. Permanent paraplegia developed in 6.8% (n = 3) of patients. The mean follow-up was 12 months (range 0-52 months). Three late deaths (6.8%) occurred, one related to an aortic graft infection. Kaplan-Meier estimated 1-year survival manifested at 95% and branch patency at 98% (177/180). Re-intervention was necessary for a total of six patients (13.6%). Conclusions Inner-branch aortic stent grafts provide a feasible option for the treatment of complex aortic pathologies, both elective (custom-made) and urgent (off-the-shelf). The technical success rate is high with acceptable short-term outcomes and moderate re-intervention rates comparable to existing platforms. Further follow-up will evaluate long-term outcomes.
Collapse
Affiliation(s)
- Marvin Kapalla
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Albert Busch
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Brigitta Lutz
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Heiner Nebelung
- Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Steffen Wolk
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Christian Reeps
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| |
Collapse
|
13
|
Piazza M, Squizzato F, Pratesi G, Tshomba Y, Gaggiano A, Gatta E, Simonte G, Piffaretti G, Frigatti P, Veraldi GF, Silingardi R, Antonello M. Editor's Choice - Early Outcomes of a Novel Off the Shelf Preloaded Inner Branch Endograft for the Treatment of Complex Aortic Pathologies in the ItaliaN Branched Registry of E-nside EnDograft (INBREED). Eur J Vasc Endovasc Surg 2023; 65:811-817. [PMID: 36871927 DOI: 10.1016/j.ejvs.2023.02.076] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 02/02/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023]
Abstract
OBJECTIVE The aim of this study was to investigate the early outcomes of a novel off the shelf pre-loaded inner branched thoraco-abdominal endograft (E-nside) in the treatment of aortic pathologies. METHODS Data from a physician initiated national multicentre registry on patients treated with the E-nside endograft, were prospectively collected and analysed. Pre-operative clinical and anatomical characteristics, procedural data, and early outcomes (90 days) were recorded in a dedicated electronic data capture system. The primary endpoint was technical success. Secondary endpoints were early mortality (90 days), procedural metrics, target vessel patency, endoleak rate, and major adverse events (MAEs) at 90 days. RESULTS In total, 116 patients from 31 Italian centres were included. Mean ± standard deviation (SD) patient age was 73 ± 8 years and 76 (65.5%) were male. Aortic pathologies included degenerative aneurysm in 98 (84.5%), post-dissection aneurysm in five (4.3%), pseudoaneurysm in six (5.2%), penetrating aortic ulcer or intramural haematoma in four (3.4%), and subacute dissection in three (2.6%). Mean ± SD aneurysm diameter was 66 ± 17 mm; aneurysm extent was Crawford I - III in 55 (50.4%), IV in 21 (19.2%), pararenal in 29 (26.7%), and juxtarenal in four (3.7%). The procedure setting was urgent in 25 (21.5%) patients. Median procedural time was 240 minutes (interquartile range [IQR] 195, 303), with a median contrast volume of 175 mL (IQR 120, 235). The endograft's technical success rate was 98.2% and the 90 day mortality rate was 5.2% (n = 6; 2.1% for elective repair and 16% for urgent repair). The 90-days cumulative MAE rate was 24.1% (n = 28). At 90 days, there were 10 (2.3%) target vessel related events (nine occlusions and one type IC endoleak) and one type 1A endoleak requiring re-intervention. CONCLUSION In this real life, non-sponsored registry, the E-nside endograft was used for the treatment of a broad spectrum of aortic pathologies, including urgent cases and different anatomies. The results showed excellent technical implantation safety and efficacy, as well as early outcomes. Longer term follow up is needed to better define the clinical role of this novel endograft.
Collapse
Affiliation(s)
- Michele Piazza
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
| | - Francesco Squizzato
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Giovanni Pratesi
- Vascular and Endovascular Surgery Unit, Ospedale Policlinico San Martino, University of Genoa, Genoa, Italy
| | - Yamume Tshomba
- Unit of Vascular Surgery, Fondazione Policlinico Universitario A. Gemelli I.R.C.C.S., Università Cattolica del Sacro Cuore, Rome, Italy
| | - Andrea Gaggiano
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Emanuele Gatta
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, Ancona, Italy
| | - Gioele Simonte
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy
| | - Gabriele Piffaretti
- Vascular Surgery, Department of Medicine and Surgery, ASST Settelaghi University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy
| | - Paolo Frigatti
- Division of Vascular Surgery, Azienda Sanitaria Universitaria Friuli Centrale, S. Maria della Misericordia University Hospital of Udine, Udine, Italy
| | | | - Roberto Silingardi
- Division of Vascular Surgery, University Hospital of Modena and Reggio Emilia, Baggiovara (MO), Italy
| | - Michele Antonello
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| |
Collapse
|
14
|
Spath P, Tsilimparis N, Furlan F, Hamwi T, Prendes CF, Stana J. Additional Aortic Coverage With an Off The Shelf, Multibranched Endograft Compared With Custom Made Devices For Endovascular Repair of Pararenal Abdominal Aortic Aneurysms. Eur J Vasc Endovasc Surg 2023; 65:710-718. [PMID: 36707021 DOI: 10.1016/j.ejvs.2023.01.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 10/07/2022] [Accepted: 01/16/2023] [Indexed: 01/26/2023]
Abstract
OBJECTIVE Pararenal abdominal aortic aneurysms (p-AAA) require complex endovascular aortic repair or open surgical repair with suprarenal clamping. Custom made devices (CMD), including fenestrated and branched endovascular aortic repair (F/B-EVAR) or off the shelf (OTS) multibranched devices, are available treatment options. The aim of this study was to determine the additional healthy aortic coverage using an OTS multibranched endograft vs. a CMD for the treatment of p-AAAs. METHODS This was a retrospective single centre analysis of prospectively collected data. Consecutive patients with p-AAAs requiring a proximal landing zone above the coeliac artery (CA), planned and treated with CMDs (Zenith Fenestrated) between January 2017 and December 2021 were included in this study. Treatment with supracoeliac coverage using available OTS multibranched devices was simulated using available pre-operative images: T-Branch; E-nside; and TAMBE. Study endpoints included the need for additional proximal aortic coverage, and the number of the segmental arteries additionally covered proximally from the CA for OTS devices compared with CMDs. RESULTS Eighty three patients with p-AAAs were treated with CMDs (all FEVAR), including juxtarenal AAAs (n = 46; 56%), suprarenal AAAs (n = 20; 24%), and short neck AAAs (n = 17; 20%). In this study, treatment with 249 (3 × 83) OTS endografts was simulated. When compared with CMDs, OTS devices required a mean of 74 ± 19 mm of additional proximal healthy aortic coverage from the CA (CMD: 33 ± 19 mm vs. OTS: 108 ± 6 mm; p ≤ .001), as well as an average sacrifice of 2.5 additional segmental arteries (CMD: 1.3 ± 0.8 vs. OTS: 3.8 ± 0.9; p ≤ .001). In 94% of patients, at least one of the available multibranched endografts could have been implanted in accordance with instructions for use. CONCLUSION Despite not requiring customisation time, OTS endografts for the treatment of p-AAA lead to more extensive healthy aortic coverage, as well as an average sacrifice of 2.5 additional segmental arteries, compared with CMDs. When compared with OTS devices, CMDs appear to limit the extent of unnecessary aortic coverage and the theoretical subsequent risk of spinal cord ischaemia.
Collapse
Affiliation(s)
- Paolo Spath
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| | - Nikolaos Tsilimparis
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany.
| | - Federico Furlan
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| | - Tarek Hamwi
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| | - Carlota F Prendes
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| | - Jan Stana
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| |
Collapse
|
15
|
Surgeon-modified fenestrated endograft for urgent an aortic arch aneurysm: case report. J Cardiothorac Surg 2023; 18:7. [PMID: 36611164 PMCID: PMC9824962 DOI: 10.1186/s13019-023-02102-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 01/02/2023] [Indexed: 01/09/2023] Open
Abstract
We report the case of an endovascular repair of an aortic arch aneurysm by a surgeon-modified fenestrated endograft with a single fenestration in a high-risk patient unfit for open surgery. A patient of 84 years, chronic ischemic cardiopathic, suffering from prostate adenocarcinoma in chemotherapy treatment, came to our hospital for post-traumatic fracture of the right femur. During the hospitalization, the patient exhibited dysphonia and respiratory disorders for several days, therefore, the patient performed Computed Tomography Angiography (CTA) that found the presence of voluminous aneurysm of the aortic arch with a maximum diameter of about 74 mm. The patient was treated with a hybrid-staged procedure; in the first instance, with a carotid-carotid-succlavium bypass to preserve the cerebral and upper limb vascularization and then, the procedure was completed by implanting the surgeon-modified fenestrated endograft with stent delivery to the patient with a fenestration on the anonymous trunk. This surgeon-modified fenestrated endograft was created by modifying a standard endograft by a single fenestration following the three-dimensional reconstructions of the CTA images. The procedure was successfully completed and postoperative course was uneventful. Computed Tomography Angiography demonstrated the exclusion of the aneurysm, patency of the implanted endograft modules, and absence of signs of endoleaks and / or cerebral or medullary ischemic complications.
Collapse
|
16
|
Lescan M. [Status of the Inner Branches in Complex Endovascular Aortic Repair]. Zentralbl Chir 2022; 147:447-452. [PMID: 36220065 DOI: 10.1055/a-1938-8269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Complex endovascular therapy of the aorta with fenestrated and branched endografts plays an essential role in modern vascular medicine. Innovative solutions for demanding aortic pathologies are therefore being constantly developed by the medical industry. The aim of this manuscript is to illustrate the growing importance of the inner branches in complex aortic repair and to show the advantages and limits of this technique with an overview of the current literature. The inner branches (iBEVAR) were therefore compared to the standard treatment options (fenestrations; [FEVAR], outer branches [BEVAR]) and the technical advantages of all platforms were evaluated. The widespread use of iBEVAR in the aortic arch stands in contrast to the thoracoabdominal aorta, which is mirrored by the scarce evidence for the thoracoabdominal inner branches. The published experience is based on smaller retrospective studies with a 1-year follow-up. The E-nside (Artivion, Hechingen, Germany) thoracoabdominal off-the-shelf inner-branch-based endograft was released 2 years ago. Its widespread deployment may increase the use of the inner branches in the thoracoabdominal aorta. Moreover, an ongoing industry-funded registry may provide new insights into the long-term durability of this innovative technique.
Collapse
Affiliation(s)
- Mario Lescan
- Klinik für Thorax-, Herz- und Gefäßchirurgie, Sektion Gefäßchirurgie, Universitätsklinikum Tübingen, Tübingen, Deutschland
| |
Collapse
|
17
|
Tinelli G, Minelli F, Donato F, Sica S, De Nigris F, Tshomba Y. Through-and-through femorofemoral wire retrograde technique for the E-nside precannulated inner branch thoracoabdominal stent graft. J Vasc Surg Cases Innov Tech 2022; 8:335-337. [PMID: 35812129 PMCID: PMC9263870 DOI: 10.1016/j.jvscit.2022.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Accepted: 04/11/2022] [Indexed: 11/16/2022] Open
Affiliation(s)
- Giovanni Tinelli
- Correspondence: Giovanni Tinelli, MD, PhD, Unit of Vascular Surgery, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Roma, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli, 8, Rome 00168, Italy
| | | | | | | | | | | |
Collapse
|
18
|
Szopiński P, Pleban E, Iwanowski J. The Colt Device for Treating Thoraco-Abdominal Aneurysms - Concept and Clinical Results. Rev Cardiovasc Med 2022; 23:239. [PMID: 39076916 PMCID: PMC11266783 DOI: 10.31083/j.rcm2307239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 04/03/2022] [Accepted: 04/11/2022] [Indexed: 07/31/2024] Open
Abstract
Objective To report results of application a new stent graft design for the treatment of patients with thoraco-abdominal aneurysms (TAAAs), which was co-invented by a vascular surgeon. This is a retrospective observational study. Methods The Colt is a self-expanding stent graft, composed of nitinol metal stents creating a special exoskeleton with asymmetric springs covered with polyester material. The Colt device offers some advantages over existing stent graft options. The main body is available in two different diameters on both ends and in three different lengths. It has four branches pointing downward and coming from the main stent graft at two levels. It offers the physician an opportunity to decide which branch to choose for the target vessel. It may be implanted alone or extended proximally and distally. Balloon expandable and/or self-expanding stent grafts are used to create the visceral branches. In complex extensive aneurysms, the procedure is divided into two or three stages to minimize the risks of spinal cord ischemia. Results Between August 2015 and December 2021, twenty-two Colt stent grafts were implanted in twenty males and two females (aged 56-81) with TAAAs (eight Type II; twelve Type III; two Type IV). The mean aneurysm diameter was 73.4 mm (range 64-83). All patients were asymptomatic. Eighty-five target vessels were reconstructed using either self-expanding or balloon-expandable stent grafts. Fourteen bifurcated, six custom-made tubes and two aortouniiliac (AUI) stent grafts were used as distal extensions to the Colt device. Completion angiography revealed no type I endoleaks. Five patients had Type II endoleaks which were treated conservatively. There were no intraoperative deaths. One patient died on the 7th postoperative day from multiorgan failure. We did not observe any other complications within 30 days after implantation. One patient died from Covid-19 two months after discharge. Follow-up ranged from three to 75 months. There was no migration or dislocation of the docking station or proximal and distal extensions. All Colt device prostheses remained patent, however, two branches leading to the coeliac trunk were found occluded at the time of the 12-month CTA, without any symptoms. In two patients, there were late problems with three renal bridging stent grafts. One of the Type II endoleaks resolved spontaneously after one year, while four others remain under observation. No patient had an increase in sac diameter. Conclusions Results from the current series are promising. The Colt stent graft can be applied to a large variety of TAAA anatomies, which may facilitate the development of new "off-the-shelf" devices in the future.
Collapse
Affiliation(s)
- Piotr Szopiński
- Clinic of Vascular Surgery, Institute of Hematology and Transfusion Medicine, 02-776 Warsaw, Poland
| | - Eliza Pleban
- Clinic of Vascular Surgery, Institute of Hematology and Transfusion Medicine, 02-776 Warsaw, Poland
| | - Jarosław Iwanowski
- Clinic of Vascular Surgery, Institute of Hematology and Transfusion Medicine, 02-776 Warsaw, Poland
| |
Collapse
|