Liu X, Van Slyke AL, Pearson E, Shoniyozov K, Redler G, Wiersma RD. Improving the efficiency of small animal 3D-printed compensator IMRT with beamlet intensity total variation regularization. Med Phys 2022; 49:5400-5408. [PMID: 35608256 DOI: 10.1002/mp.15764] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 02/23/2022] [Accepted: 05/11/2022] [Indexed: 12/30/2022] Open
Abstract
PURPOSE There is growing interest in the use of modern 3D printing technology to implement intensity-modulated radiation therapy (IMRT) on the preclinical scale that is analogous to clinical IMRT. However, current 3D-printed IMRT methods suffer from complex modulation patterns leading to long delivery times, excess filament usage, and less accurate compensator fabrication. In this work, we have developed a total variation regularization (TVR) approach to address these issues. METHODS TVR-IMRT was used to optimize the beamlet intensity map, which was then converted to a thickness of the corresponding compensator attenuation region in copper-doped polylactic acid (PLA) filament. IMRT and TVR-IMRT heart and lung plans were generated for two different mice using three, five, or seven gantry angles. The total compensator thickness, total variation of compensator beamlet thicknesses, total variation of beamlet intensities, and exposure time were compared. The individual field doses and composite dose were delivered to film for one plan and gamma analysis was performed. RESULTS In total, 12 mice heart and lung plans were generated for both IMRT and TVR-IMRT cases. Across all cases, it was found that TVR-IMRT reduced the total variation of compensator beamlet thicknesses and beamlet intensities by 54 ± 4 % $54\pm 4\%$ and 50 ± 3 % $50\pm 3\%$ on average when compared to standard 3D-printed compensator IMRT. On average, the total mass of compensator material consumed and radiation beam-on time were reduced by 45 ± 6 % $45\pm 6\%$ and 24 ± 4 % $24\pm 4\%$ , respectively, whereas dose metrics remained comparable. Heart plan compensators were printed and delivered to film and subsequent gamma analysis performed for each of the single fields as well as the composite dose. For the composite delivery, a passing rate of 89.1% for IMRT and 95.4% for TVR-IMRT was achieved for a 3 % / 0.3 $3\%/0.3$ mm criterion. CONCLUSIONS TVR can be applied to small animal IMRT beamlet intensities to produce fluence maps and subsequent 3D-printed compensator patterns with significantly less complexity while still maintaining similar dose conformity to traditional IMRT. This can simplify/accelerate the 3D printing process, reduce the amount of filament required, and reduce overall beam-on time to deliver a plan.
Collapse
Affiliation(s)
- Xinmin Liu
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Alexander L Van Slyke
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Erik Pearson
- Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois, USA
| | - Khayrullo Shoniyozov
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Gage Redler
- Moffitt Cancer Center, Department of Radiation Oncology, Tampa, Florida, USA
| | - Rodney D Wiersma
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
2
|
Entezam A, Fielding A, Moi D, Bradley D, Ratnayake G, Sim L, Kralik C, Fontanarosa D. Investigation of scattered dose in a mouse phantom model for pre-clinical dosimetry studies. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
3
|
Response to stereotactic ablative radiotherapy in a novel orthotopic model of non-small cell lung cancer. Oncotarget 2017; 9:1630-1640. [PMID: 29416719 PMCID: PMC5788587 DOI: 10.18632/oncotarget.22727] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2017] [Accepted: 10/28/2017] [Indexed: 12/12/2022] Open
Abstract
Stereotactic ablative radiotherapy (SABR) is the main treatment for inoperable early-stage non-small cell lung cancer (NSCLC). Despite the widespread use of SABR, the biological determinants of response to SABR remain poorly investigated. We developed an orthotopic NSCLC animal model to study the response to clinically-relevant doses of SABR. Image-guided intra-thoracic injection of NSCLC cells was performed in the right lung of nude rats. A highly conformal dose of 34 Gy was delivered in a single fraction using clinical photon energies. Animals were sacrificed 10–60 days post treatment. Lung tumors were assessed for tumor differentiation, proliferation and invasiveness. An analysis of 770 cancer-related genes was performed on tumor-derived cell lines from treated animals at early and late time points after SABR. The majority of animals receiving SABR demonstrated complete response (67%), while 33% demonstrated local failure. 50% of animals with complete response failed distantly. Analysis of cancer-related genes revealed significant differences between tumors treated with SABR and untreated tumors. SABR significantly modulated expression of genes involved in adhesion, migration and angiogenesis. In particular, interleukin-8 (IL8) which plays a critical role in promoting tumor invasion was found to be secreted at high levels after SABR. In vitro invasion assays confirmed SABR-induced invasion and demonstrated induction of IL-8 secretion in multiple NSCLC cell lines. Our findings underscore the importance of developing targeted therapies that can circumvent the pro-invasive effects of SABR in NSCLC.
Collapse
|
4
|
Karagounis IV, Abatzoglou IM, Koukourakis MI. Technical Note: Partial body irradiation of mice using a customized PMMA apparatus and a clinical 3D planning/LINAC radiotherapy system. Med Phys 2017; 43:2200. [PMID: 27147332 DOI: 10.1118/1.4945274] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In vivo radiobiology experiments involving partial body irradiation (PBI) of mice are of major importance because they allow for the evaluation of individual organ tolerance; overcoming current limitations of experiments using lower dose, whole body irradiation. In the current study, the authors characterize and validate an effective and efficient apparatus for multiple animal PBI, directed to the head, thorax, or abdomen of mice. METHODS The apparatus is made of polymethylmethacrylate and consists of a rectangular parallelepiped prism (40 cm × 16 cm × 8 cm), in which five holes were drilled to accomodate standard 60 ml syringes, each housing an unanesthetized, fully immobilized mouse. Following CT-scanning and radiotherapy treatment planning, radiation fields were designed to irradiate the head, thorax, or abdomen of the animal. Thermoluminescent dosimeters (TLDs) were used to confirm the treatment planning dosimetry for primary beam and scattered radiation. RESULTS Mice are efficiently placed into 60 ml syringes and immobilized, without the use of anesthetics. Although partial rotational movement around the longitudinal axis and a minor 2 mm forward/backward movement are permitted, this does not compromise the irradiation of the chosen body area. TLDs confirmed the dose values predicted by the treatment planning dosimetry, both for primary beam and scattered radiation. CONCLUSIONS The customized PMMA apparatus described and validated is cost-effective, convenient to use, and efficient in performing PBI without the use of anesthesia. The developed apparatus permits the isolated irradiation of the mouse head, thorax, and abdomen. Importantly, the apparatus allows the delivery of PBI to five mice, simultaneously, representing an efficient way to effectively expose a large number of animals to PBI through multiple daily fractions, simulating clinical radiotherapy treatment schedules.
Collapse
Affiliation(s)
- Ilias V Karagounis
- Department of Radiotherapy-Oncology, Radiopathology and Radiobiology Unit, Medical School, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Ioannis M Abatzoglou
- Medical Physics Department, University General Hospital of Alexandroupolis, Alexandroupolis 68100, Greece
| | - Michael I Koukourakis
- Department of Radiotherapy-Oncology, Radiopathology and Radiobiology Unit, Medical School, Democritus University of Thrace, Alexandroupolis 68100, Greece
| |
Collapse
|
5
|
Sharma S, Narayanasamy G, Przybyla B, Webber J, Boerma M, Clarkson R, Moros EG, Corry PM, Griffin RJ. Advanced Small Animal Conformal Radiation Therapy Device. Technol Cancer Res Treat 2017; 16:45-56. [PMID: 26792490 PMCID: PMC5616115 DOI: 10.1177/1533034615626011] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Revised: 12/01/2015] [Accepted: 12/16/2015] [Indexed: 11/16/2022] Open
Abstract
We have developed a small animal conformal radiation therapy device that provides a degree of geometrical/anatomical targeting comparable to what is achievable in a commercial animal irradiator. small animal conformal radiation therapy device is capable of producing precise and accurate conformal delivery of radiation to target as well as for imaging small animals. The small animal conformal radiation therapy device uses an X-ray tube, a robotic animal position system, and a digital imager. The system is in a steel enclosure with adequate lead shielding following National Council on Radiation Protection and Measurements 49 guidelines and verified with Geiger-Mueller survey meter. The X-ray source is calibrated following AAPM TG-61 specifications and mounted at 101.6 cm from the floor, which is a primary barrier. The X-ray tube is mounted on a custom-made "gantry" and has a special collimating assembly system that allows field size between 0.5 mm and 20 cm at isocenter. Three-dimensional imaging can be performed to aid target localization using the same X-ray source at custom settings and an in-house reconstruction software. The small animal conformal radiation therapy device thus provides an excellent integrated system to promote translational research in radiation oncology in an academic laboratory. The purpose of this article is to review shielding and dosimetric measurement and highlight a few successful studies that have been performed to date with our system. In addition, an example of new data from an in vivo rat model of breast cancer is presented in which spatially fractionated radiation alone and in combination with thermal ablation was applied and the therapeutic benefit examined.
Collapse
Affiliation(s)
- Sunil Sharma
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Ganesh Narayanasamy
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Beata Przybyla
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Jessica Webber
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Marjan Boerma
- Division of Radiation Health, Department of Pharmaceutical Sciences, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Richard Clarkson
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Eduardo G. Moros
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center, Tampa, FL, USA
| | - Peter M. Corry
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Robert J. Griffin
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| |
Collapse
|
6
|
Ford E, Deye J. Current Instrumentation and Technologies in Modern Radiobiology Research—Opportunities and Challenges. Semin Radiat Oncol 2016; 26:349-55. [DOI: 10.1016/j.semradonc.2016.06.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
7
|
Du S, Lockamy V, Zhou L, Xue C, LeBlanc J, Glenn S, Shukla G, Yu Y, Dicker AP, Leeper DB, Lu Y, Lu B. Stereotactic Body Radiation Therapy Delivery in a Genetically Engineered Mouse Model of Lung Cancer. Int J Radiat Oncol Biol Phys 2016; 96:529-37. [PMID: 27681749 DOI: 10.1016/j.ijrobp.2016.07.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 06/29/2016] [Accepted: 07/11/2016] [Indexed: 02/05/2023]
Abstract
PURPOSE To implement clinical stereotactic body radiation therapy (SBRT) using a small animal radiation research platform (SARRP) in a genetically engineered mouse model of lung cancer. METHODS AND MATERIALS A murine model of multinodular Kras-driven spontaneous lung tumors was used for this study. High-resolution cone beam computed tomography (CBCT) imaging was used to identify and target peripheral tumor nodules, whereas off-target lung nodules in the contralateral lung were used as a nonirradiated control. CBCT imaging helps localize tumors, facilitate high-precision irradiation, and monitor tumor growth. SBRT planning, prescription dose, and dose limits to normal tissue followed the guidelines set by RTOG protocols. Pathologic changes in the irradiated tumors were investigated using immunohistochemistry. RESULTS The image guided radiation delivery using the SARRP system effectively localized and treated lung cancer with precision in a genetically engineered mouse model of lung cancer. Immunohistochemical data confirmed the precise delivery of SBRT to the targeted lung nodules. The 60 Gy delivered in 3 weekly fractions markedly reduced the proliferation index, Ki-67, and increased apoptosis per staining for cleaved caspase-3 in irradiated lung nodules. CONCLUSIONS It is feasible to use the SARRP platform to perform dosimetric planning and delivery of SBRT in mice with lung cancer. This allows for preclinical studies that provide a rationale for clinical trials involving SBRT, especially when combined with immunotherapeutics.
Collapse
Affiliation(s)
- Shisuo Du
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Virginia Lockamy
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Lin Zhou
- Department of Thoracic Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Christine Xue
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Justin LeBlanc
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | | | - Gaurav Shukla
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Yan Yu
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Adam P Dicker
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Dennis B Leeper
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - You Lu
- Department of Thoracic Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Bo Lu
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania.
| |
Collapse
|
8
|
Tinnel B, Mendonca MS, Henderson M, Cummings O, Chin-Sinex H, Timmerman R, McGarry RC. Pulmonary Hilar Stereotactic Body Radiation Therapy in the Rat. Technol Cancer Res Treat 2016; 6:425-31. [PMID: 17877431 DOI: 10.1177/153303460700600508] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Stereotactic Body Radiation therapy (SBRT) is an emerging modality of treatment for early stage non-small cell lung carcinoma. Concerns have arisen related to increased toxicities for medial tumors. We have developed a model of high dose, hypofractionated radiotherapy to the pulmonary hilum using the Leksell Gamma-Knife™. Sprague-Dawley rats received hypofractionated SBRT to the unilateral lung hilum using a custom immobilization device on the Gamma Knife. Each animal was individually scanned, treatment planned, and treated with either two 4 mm or one 8 mm collimated shots at escalating doses of 20, 40, and 80 Gy to the 50% isodose volume, encompassing the right mainstem bronchus. All animals were carefully followed post-treatment and imaged by plain film and CT. In addition, histopathological analysis of all rats was performed at selected time points. Animals treated with 4 mm collimated shots demonstrated no appreciable changes on plain films or sequential, follow-up CT scans, or histopathologically. Animals irradiated with the 8 mm collimator were less active, gained weight at a reduced rate, and demonstrated histopathological changes in 7/34 animals six months post-irradiation. Cellular atypia and interstitial pneumonitis were found, three of the seven of the animals showed clear bronchial damage and two showed vascular damage. Significant volume and time effects were found. Utilizing a novel Gamma Knife based animal model to study SBRT toxicity, it was found that the bronchus will tolerate small volumes of very high dose radiotherapy. It was postulated that radiation of the surrounding support stroma and normal tissue are important in the etiology of bronchial or hilar damage.
Collapse
Affiliation(s)
- B Tinnel
- Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | | | | | | | | | | | | |
Collapse
|
9
|
Stewart JMP, Ansell S, Lindsay PE, Jaffray DA. Online virtual isocenter based radiation field targeting for high performance small animal microirradiation. Phys Med Biol 2015; 60:9031-46. [PMID: 26540304 DOI: 10.1088/0031-9155/60/23/9031] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Advances in precision microirradiators for small animal radiation oncology studies have provided the framework for novel translational radiobiological studies. Such systems target radiation fields at the scale required for small animal investigations, typically through a combination of on-board computed tomography image guidance and fixed, interchangeable collimators. Robust targeting accuracy of these radiation fields remains challenging, particularly at the millimetre scale field sizes achievable by the majority of microirradiators. Consistent and reproducible targeting accuracy is further hindered as collimators are removed and inserted during a typical experimental workflow. This investigation quantified this targeting uncertainty and developed an online method based on a virtual treatment isocenter to actively ensure high performance targeting accuracy for all radiation field sizes. The results indicated that the two-dimensional field placement uncertainty was as high as 1.16 mm at isocenter, with simulations suggesting this error could be reduced to 0.20 mm using the online correction method. End-to-end targeting analysis of a ball bearing target on radiochromic film sections showed an improved targeting accuracy with the three-dimensional vector targeting error across six different collimators reduced from [Formula: see text] mm (mean ± SD) to [Formula: see text] mm for an isotropic imaging voxel size of 0.1 mm.
Collapse
Affiliation(s)
- James M P Stewart
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3E2, Canada. Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
| | | | | | | |
Collapse
|
10
|
Tillner F, Thute P, Bütof R, Krause M, Enghardt W. Pre-clinical research in small animals using radiotherapy technology – a bidirectional translational approach. Z Med Phys 2014; 24:335-51. [DOI: 10.1016/j.zemedi.2014.07.004] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2013] [Revised: 07/18/2014] [Accepted: 07/18/2014] [Indexed: 01/17/2023]
|
11
|
Verhaegen F, van Hoof S, Granton PV, Trani D. A review of treatment planning for precision image-guided photon beam pre-clinical animal radiation studies. Z Med Phys 2014; 24:323-34. [DOI: 10.1016/j.zemedi.2014.02.004] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2013] [Revised: 02/14/2014] [Accepted: 02/17/2014] [Indexed: 12/31/2022]
|
12
|
Historical Development of Stereotactic Ablative Radiotherapy. STEREOTACTIC BODY RADIATION THERAPY 2012. [DOI: 10.1007/174_2012_540] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
13
|
Yoshizumi T, Brady SL, Robbins ME, Bourland JD. Specific issues in small animal dosimetry and irradiator calibration. Int J Radiat Biol 2011; 87:1001-10. [PMID: 21961967 DOI: 10.3109/09553002.2011.556178] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE In response to the increased risk of radiological terrorist attack, a network of Centers for Medical Countermeasures against Radiation (CMCR) has been established in the United States, focusing on evaluating animal model responses to uniform, relatively homogenous whole- or partial-body radiation exposures at relatively high dose rates. The success of such studies is dependent not only on robust animal models but on accurate and reproducible dosimetry within and across CMCR. To address this issue, the Education and Training Core of the Duke University School of Medicine CMCR organised a one-day workshop on small animal dosimetry. Topics included accuracy in animal dosimetry accuracy, characteristics and differences of cesium-137 and X-ray irradiators, methods for dose measurement, and design of experimental irradiation geometries for uniform dose distributions. This paper summarises the information presented and discussed. CONCLUSIONS Without ensuring accurate and reproducible dosimetry the development and assessment of the efficacy of putative countermeasures will not prove successful. Radiation physics support is needed, but is often the weakest link in the small animal dosimetry chain. We recommend: (i) A user training program for new irradiator users, (ii) subsequent training updates, and (iii) the establishment of a national small animal dosimetry center for all CMCR members.
Collapse
Affiliation(s)
- Terry Yoshizumi
- Department of Radiology, Duke University, Durham, NC 27157, USA
| | | | | | | |
Collapse
|
14
|
Ngwa W, Korideck H, Chin LM, Makrigiorgos GM, Berbeco RI. MOSFET assessment of radiation dose delivered to mice using the Small Animal Radiation Research Platform (SARRP). Radiat Res 2011; 176:816-20. [PMID: 21962005 DOI: 10.1667/rr2536.1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The Small Animal Radiation Research Platform (SARRP) is a novel isocentric irradiation system that enables state-of-the-art image-guided radiotherapy research to be performed with animal models. This paper reports the results obtained from investigations assessing the radiation dose delivered by the SARRP to different anatomical target volumes in mice. Surgically implanted metal oxide semiconductor field effect transistors (MOSFET) dosimeters were employed for the dose assessment. The results reveal differences between the calculated and measured dose of -3.5 to 0.5%, -5.2 to -0.7%, -3.9 to 0.5%, -5.9 to 2.5%, -5.5 to 0.5%, and -4.3 to 0% for the left kidney, liver, pancreas, prostate, left lung, and brain, respectively. Overall, the findings show less than 6% difference between the delivered and calculated dose, without tissue heterogeneity corrections. These results provide a useful assessment of the need for tissue heterogeneity corrections in SARRP dose calculations for clinically relevant tumor model sites.
Collapse
Affiliation(s)
- Wilfred Ngwa
- Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women's Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115, USA
| | | | | | | | | |
Collapse
|
15
|
Song KH, Pidikiti R, Stojadinovic S, Speiser M, Seliounine S, Saha D, Solberg TD. An x-ray image guidance system for small animal stereotactic irradiation. Phys Med Biol 2010; 55:7345-62. [DOI: 10.1088/0031-9155/55/23/011] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
16
|
Cho J, Kodym R, Seliounine S, Richardson JA, Solberg TD, Story MD. High dose-per-fraction irradiation of limited lung volumes using an image-guided, highly focused irradiator: simulating stereotactic body radiotherapy regimens in a small-animal model. Int J Radiat Oncol Biol Phys 2010; 77:895-902. [PMID: 20510200 DOI: 10.1016/j.ijrobp.2009.12.074] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2009] [Revised: 12/24/2009] [Accepted: 12/29/2009] [Indexed: 11/16/2022]
Abstract
PURPOSE To investigate the underlying biology associated with stereotactic body radiotherapy (SBRT), both in vivo models and image-guided, highly focal irradiation systems are necessary. Here, we describe such an irradiation system and use it to examine normal tissue toxicity in a small-animal model at lung volumes similar to those associated with human therapy. METHODS AND MATERIALS High-dose radiation was delivered to a small volume of the left lung of C3H/HeJCr mice using a small-animal stereotactic irradiator. The irradiator has a collimation mechanism to produce focal radiation beams, an imaging subsystem consisting of a fluorescent screen coupled to a charge-coupled device camera, and a manual positioning stage. Histopathologic examination and micro-CT were used to evaluate the radiation response. RESULTS Focal obliteration of the alveoli by fibrous connective tissue, hyperplasia of the bronchiolar epithelium, and presence of a small number of inflammatory cells are the main reactions to low-volume/high-dose irradiation of the mouse lung. The tissue response suggested a radiation dose threshold for early phase fibrosis lying between 40 and 100 Gy. The irradiation system satisfied our requirements of high-dose-rate, small beam diameter, and precise localization and verification. CONCLUSIONS We have established an experimental model and image-guided animal irradiation system for the study of high dose per fraction irradiations such as those used with SBRT at volumes analogous to those used in human beings. It will also allow the targeting of specific anatomical structures of the thorax or ultimately, orthotopic tumors of the lung.
Collapse
Affiliation(s)
- Jaeho Cho
- Division of Molecular Radiation Biology, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75093, USA
| | | | | | | | | | | |
Collapse
|
17
|
Henderson MA, Valluri S, DesRosiers C, Lopez JT, Batuello CN, Caperell-Grant A, Mendonca MS, Powers EM, Bigsby RM, Dynlacht JR. Effect of Gender on Radiation-Induced Cataractogenesis. Radiat Res 2009; 172:129-33. [DOI: 10.1667/rr1589.1] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
18
|
Rodriguez M, Zhou H, Keall P, Graves E. Commissioning of a novel microCT/RT system for small animal conformal radiotherapy. Phys Med Biol 2009; 54:3727-40. [PMID: 19478377 DOI: 10.1088/0031-9155/54/12/008] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The purpose of this work was to commission a 120 kVp photon beam produced by a micro-computed tomography (microCT) scanner for use in irradiating mice to therapeutic doses. A variable-aperture collimator has been integrated with a microCT scanner to allow the delivery of beams with pseudocircular profiles of arbitrary width between 0.1 and 6.0 cm. The dose rate at the isocenter of the system was measured using ion chamber and gafchromic EBT film as 1.56-2.13 Gy min(-1) at the water surface for field diameters between 0.2 and 6.0 cm. The dose rate decreases approximately 10% per every 5 mm depth in water for field diameters between 0.5 and 1.0 cm. The flatness, symmetry and penumbra of the beam are 3.6%, 1.0% and 0.5 mm, respectively. These parameters are sufficient to accurately conform the radiation dose delivered to target organs on mice. The irradiated field size is affected principally by the divergence of the beam. In general, the beam has appropriate dosimetric characteristics to accurately deliver the dose to organs inside the mice's bodies. Using multiple beams delivered from a variety of angular directions, targets as small as 2 mm may be irradiated while sparing surrounding tissue. This microCT/RT system is a feasible tool to irradiate mice using treatment planning and delivery methods analogous to those applied to humans.
Collapse
|
19
|
A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery. Int J Radiat Oncol Biol Phys 2009; 73:1588-95. [DOI: 10.1016/j.ijrobp.2008.11.038] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2008] [Revised: 10/31/2008] [Accepted: 11/22/2008] [Indexed: 11/21/2022]
|
20
|
Dynlacht JR, Valluri S, Lopez J, Greer F, Desrosiers C, Caperell-Grant A, Mendonca MS, Bigsby RM. Estrogen protects against radiation-induced cataractogenesis. Radiat Res 2009; 170:758-64. [PMID: 19138041 DOI: 10.1667/rr1416.1] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2008] [Accepted: 08/11/2008] [Indexed: 12/14/2022]
Abstract
Cataractogenesis is a complication of radiotherapy when the eye is included in the treatment field. Low doses of densely ionizing space radiation may also result in an increased risk of cataracts in astronauts. We previously reported that estrogen (17-beta-estradiol), when administered to ovariectomized rats commencing 1 week before gamma irradiation of the eye and continuously thereafter, results in a significant increase in the rate and incidence of cataract formation and a decreased latent period compared to an ovariectomized control group. We therefore concluded that estrogen accelerates progression of radiation-induced opacification. We now show that estrogen, if administered continuously, but commencing after irradiation, protects against radiation cataractogenesis. Both the rate of progression and incidence of cataracts were greatly reduced in ovariectomized rats that received estrogen treatment after irradiation compared to ovariectomized rats. As in our previous study, estradiol administered 1 week prior to irradiation at the time of ovariectomy and throughout the period of observation produced an enhanced rate of cataract progression. Estrogen administered for only 1 week prior to irradiation had no effect on the rate of progression but resulted in a slight reduction in the incidence. We conclude that estrogen may enhance or protect against radiation cataractogenesis, depending on when it is administered relative to the time of irradiation, and may differentially modulate the initiation and progression phases of cataractogenesis. These data have important implications for astronauts and radiotherapy patients.
Collapse
Affiliation(s)
- Joseph R Dynlacht
- Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202, USA.
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Matinfar M, Ford E, Iordachita I, Wong J, Kazanzides P. Image-guided small animal radiation research platform: calibration of treatment beam alignment. Phys Med Biol 2009; 54:891-905. [PMID: 19141881 DOI: 10.1088/0031-9155/54/4/005] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Small animal research allows detailed study of biological processes, disease progression and response to therapy with the potential to provide a natural bridge to the clinical environment. The small animal radiation research platform (SARRP) is a portable system for precision irradiation with beam sizes down to approximately 0.5 mm and optimally planned radiation with on-board cone-beam CT (CBCT) guidance. This paper focuses on the geometric calibration of the system for high-precision irradiation. A novel technique for the calibration of the treatment beam is presented, which employs an x-ray camera whose precise positioning need not be known. Using the camera system we acquired a digitally reconstructed 3D 'star shot' for gantry calibration and then developed a technique to align each beam to a common isocenter with the robotic animal positioning stages. The calibration incorporates localization by cone-beam CT guidance. Uncorrected offsets of the beams with respect to the calibration origin ranged from 0.4 mm to 5.2 mm. With corrections, these alignment errors can be reduced to the sub-millimeter range. The calibration technique was used to deliver a stereotactic-like arc treatment to a phantom constructed with EBT Gafchromic films. All beams were shown to intersect at a common isocenter with a measured beam (FWHM) of approximately 1.07 mm using the 0.5 mm collimated beam. The desired positioning accuracy of the SARRP is 0.25 mm and the results indicate an accuracy of 0.2 mm. To fully realize the radiation localization capabilities of the SARRP, precise geometric calibration is required, as with any such system. The x-ray camera-based technique presented here provides a straightforward and semi-automatic method for system calibration.
Collapse
Affiliation(s)
- Mohammad Matinfar
- Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA
| | | | | | | | | |
Collapse
|
22
|
Kiehl EL, Stojadinovic S, Malinowski KT, Limbrick D, Jost SC, Garbow JR, Rubin JB, Deasy JO, Khullar D, Izaguirre EW, Parikh PJ, Low DA, Hope AJ. Feasibility of small animal cranial irradiation with the microRT system. Med Phys 2008; 35:4735-43. [PMID: 18975718 DOI: 10.1118/1.2977762] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To develop and validate methods for small-animal CNS radiotherapy using the microRT system. MATERIALS AND METHODS A custom head immobilizer was designed and built to integrate with a pre-existing microRT animal couch. The Delrin couch-immobilizer assembly, compatible with multiple imaging modalities (CT, microCT, microMR, microPET, microSPECT, optical), was first imaged via CT in order to verify the safety and reproducibility of the immobilization method. Once verified, the subject animals were CT-scanned while positioned within the couch-immobilizer assembly for treatment planning purposes. The resultant images were then imported into CERR, an in-house-developed research treatment planning system, and registered to the microRTP treatment planning space using rigid registration. The targeted brain was then contoured and conformal radiotherapy plans were constructed for two separate studies: (1) a whole-brain irradiation comprised of two lateral beams at the 90 degree and 270 degree microRT treatment positions and (2) a hemispheric (left-brain) irradiation comprised of a single A-P vertex beam at the 0 degree microRT treatment position. During treatment, subject animals (n=48) were positioned to the CERR-generated treatment coordinates using the three-axis microRT motor positioning system and were irradiated using a clinical Ir-192 high-dose-rate remote after-loading system. The radiation treatment course consisted of 5 Gy fractions, 3 days per week. 90% of the subjects received a total dose of 30 Gy and 10% received a dose of 60 Gy. RESULTS Image analysis verified the safety and reproducibility of the immobilizer. CT scans generated from repeated reloading and repositioning of the same subject animal in the couch-immobilizer assembly were fused to a baseline CT. The resultant analysis revealed a 0.09 mm average, center-of-mass translocation and negligible volumetric error in the contoured, murine brain. The experimental use of the head immobilizer added 0.1 mm to microRT spatial uncertainty along each axis. Overall, the total spatial uncertainty for the prescribed treatments was +/-0.3 mm in all three axes, a 0.2 mm functional improvement over the original version of microRT. Subject tolerance was good, with minimal observed side effects and a low procedure-induced mortality rate. Throughput was high, with average treatment times of 7.72 and 3.13 min/animal for the whole-brain and hemispheric plans, respectively (dependent on source strength). CONCLUSIONS The method described exhibits conformality more in line with the size differential between human and animal patients than provided by previous prevalent approaches. Using pretreatment imaging and microRT-specific treatment planning, our method can deliver an accurate, conformal dose distribution to the targeted murine brain (or a subregion of the brain) while minimizing excess dose to the surrounding tissue. Thus, preclinical animal studies assessing the radiotherapeutic response of both normal and malignant CNS tissue to complex dose distributions, which closer resemble human-type radiotherapy, are better enabled. The procedural and mechanistic framework for this method logically provides for future adaptation into other murine target organs or regions.
Collapse
Affiliation(s)
- Erich L Kiehl
- Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Wong J, Armour E, Kazanzides P, Iordachita I, Tryggestad E, Deng H, Matinfar M, Kennedy C, Liu Z, Chan T, Gray O, Verhaegen F, McNutt T, Ford E, DeWeese TL. High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities. Int J Radiat Oncol Biol Phys 2008; 71:1591-9. [PMID: 18640502 DOI: 10.1016/j.ijrobp.2008.04.025] [Citation(s) in RCA: 279] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2008] [Revised: 04/10/2008] [Accepted: 04/11/2008] [Indexed: 10/21/2022]
Abstract
PURPOSE To demonstrate the computed tomography, conformal irradiation, and treatment planning capabilities of a small animal radiation research platform (SARRP). METHODS AND MATERIALS The SARRP uses a dual-focal spot, constant voltage X-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120 degrees from vertical. X-rays of 80-100 kVp from the smaller 0.4-mm focal spot are used for imaging. Both 0.4-mm and 3.0-mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam computed tomography is achieved by rotating the horizontal animal between the stationary X-ray source and a flat-panel detector. The radiation beams range from 0.5 mm in diameter to 60 x 60 mm(2). Dosimetry is measured with radiochromic films. Monte Carlo dose calculations are used for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. RESULTS The SARRP spans 3 ft x 4 ft x 6 ft (width x length x height). Depending on the filtration, the isocenter dose outputs at a 1-cm depth in water were 22-375 cGy/min from the smallest to the largest radiation fields. The 20-80% dose falloff spanned 0.16 mm. Cone-beam computed tomography with 0.6 x 0.6 x 0.6 mm(3) voxel resolution was acquired with a dose of <1 cGy. Treatment planning was performed at submillimeter resolution. CONCLUSION The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation.
Collapse
Affiliation(s)
- John Wong
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, 401 N. Broadway, Baltimore, MD 21231, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Keller BM, Peressotti C, Pignol JP. Optical imaging analysis of microscopic radiation dose gradients in Gafchromic EBT film using a digital microscope. Med Phys 2008; 35:3740-7. [DOI: 10.1118/1.2953565] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
25
|
Rodriguez M, Jeraj R. Design of a radiation facility for very small specimens used in radiobiology studies. Phys Med Biol 2008; 53:2953-70. [PMID: 18475005 DOI: 10.1088/0031-9155/53/11/013] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A design of a radiation facility for very small specimens used in radiobiology is presented. This micro-irradiator has been primarily designed to irradiate partial bodies in zebrafish embryos 3-4 mm in length. A miniature x-ray, 50 kV photon beam, is used as a radiation source. The source is inserted in a cylindrical brass collimator that has a pinhole of 1.0 mm in diameter along the central axis to produce a pencil photon beam. The collimator with the source is attached underneath a computer-controlled movable table which holds the specimens. Using a 45 degrees tilted mirror, a digital camera, connected to the computer, takes pictures of the specimen and the pinhole collimator. From the image provided by the camera, the relative distance from the specimen to the pinhole axis is calculated and coordinates are sent to the movable table to properly position the samples in the beam path. Due to its monitoring system, characteristic of the radiation beam, accuracy and precision of specimen positioning, and automatic image-based specimen recognition, this radiation facility is a suitable tool to irradiate partial bodies in zebrafish embryos, cell cultures or any other small specimen used in radiobiology research.
Collapse
Affiliation(s)
- Manuel Rodriguez
- Department of Medical Physics, University of Wisconsin-Madison, 1530 Medical Science Center, 1300 University Ave, Madison, WI 53706, USA.
| | | |
Collapse
|
26
|
Graves EE, Zhou H, Chatterjee R, Keall PJ, Gambhir SS, Contag CH, Boyer AL. Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner. Med Phys 2008; 34:4359-67. [PMID: 18072501 DOI: 10.1118/1.2789498] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Treatment of small animals with radiation has in general been limited to planar fields shaped with lead blocks, complicating spatial localization of dose and treatment of deep-seated targets. In order to advance laboratory radiotherapy toward what is accomplished in the clinic, we have constructed a variable aperture collimator for use in shaping the beam of microCT scanner. This unit can image small animal subjects at high resolution, and is capable of delivering therapeutic doses in reasonable exposure times. The proposed collimator consists of two stages, each containing six trapezoidal brass blocks that move along a frame in a manner similar to a camera iris producing a hexagonal aperture of variable size. The two stages are offset by 30 degrees and adjusted for the divergence of the x-ray beam so as to produce a dodecagonal profile at isocenter. Slotted rotating driving plates are used to apply force to pins in the collimator blocks and effect collimator motion. This device has been investigated through both simulation and measurement. The collimator aperture size varied from 0 to 8.5 cm as the driving plate angle increased from 0 to 41 degrees. The torque required to adjust the collimator varied from 0.5 to 5 N x m, increasing with increasing driving plate angle. The transmission profiles produced by the scanner at isocenter exhibited a penumbra of approximately 10% of the collimator aperture width. Misalignment between the collimator assembly and the x-ray source could be identified on the transmission images and corrected by adjustment of the collimator location. This variable aperture collimator technology is therefore a feasible and flexible solution for adjustable shaping of radiation beams for use in small animal radiotherapy as well as other applications in which beam shaping is desired.
Collapse
Affiliation(s)
- Edward E Graves
- Department of Radiology Oncology, Molecular Imaging Program at Stanford, Stanford University, Stanford, California 94305, USA.
| | | | | | | | | | | | | |
Collapse
|
27
|
Precision Radiotherapy for Small Animal Research. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION – MICCAI 2008 2008; 11:619-26. [DOI: 10.1007/978-3-540-85990-1_74] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
28
|
Stojadinovic S, Low DA, Vicic M, Mutic S, Deasy JO, Hope AJ, Parikh PJ, Grigsby PW. Progress toward a microradiation therapy small animal conformal irradiator. Med Phys 2006; 33:3834-45. [PMID: 17089848 DOI: 10.1118/1.2349693] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Microradiation therapy (microRT) systems are being designed to provide conformal radiation therapy to small animals enabling quantitative radiation response evaluation. We used a Monte Carlo approach to estimate the radiation dose distributions from proposed blueprints and developed a beam model to aid in the microRT system design process. This process was applied to a prototype irradiator that uses a small (3 mm long and 3 mm in diameter), cylindrical, high-activity 192Ir source delivering the radiation beam using custom-fabricated tungsten collimators. The BEAMnrc Monte Carlo code was used to simulate dose distributions from these prototype collimators. Simulations were performed at three source-to-surface distances (50, 60, and 70 mm), and with five circular field sizes (5, 7.5, 10, 12.5, and 15 mm). A dose to a 50 X 50 X 50 mm3 water phantom with 1 X 1 X 1 mm3 voxel spacing was computed. A multiparameter dose calculation algorithm was developed to efficiently and accurately calculate doses for treatment planning exercises. The parametrization was selected so that the parameters varied smoothly as a function of depth, source-to-surface distance, and field size, allowing interpolation for geometries that were not simulated using the Monte Carlo simulation. Direct comparison of the model with the Monte Carlo simulations showed that the variations were within 5% error for field sizes larger than 10 mm, and up to 10% for smaller field sizes.
Collapse
|
29
|
Dynlacht JR, Tyree C, Valluri S, DesRosiers C, Caperell-Grant A, Mendonca MS, Timmerman R, Bigsby RM. Effect of Estrogen on Radiation-Induced Cataractogenesis. Radiat Res 2006; 165:9-15. [PMID: 16392957 DOI: 10.1667/rr3481.1] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Cataractogenesis is a widely reported late effect that is observed in patients receiving total-body irradiation (TBI) prior to bone marrow transplantation or radiotherapy for ocular or head and neck cancers. Recent studies indicate that estrogens may protect against age-related and drug-induced cataracts. Moreover, other reports suggest that estrogen possesses antioxidant properties. Since the effect of estrogen on radiation cataractogenesis is unknown, we wished to determine whether estrogen modulates radiation-induced opacification of the lens. Intact or ovariectomized Sprague-Dawley rats were treated with either 17-beta-estradiol or an empty silastic capsule. The right orbit was then irradiated with either 10 or 15 Gy of (60)Co gamma rays using a Leksell Gamma Knife, and lenses were examined at various times postirradiation with a slit lamp or evaluated for light transmission. We found that for ovariectomized rats irradiated with 15 Gy, the lens opacity and the incidence of cataract formation in the estradiol-treated group were significantly increased compared to the control group at the end of the 25-week period of observation. Cataract incidence was also high in irradiated eyes of ovary-intact animals at 25 weeks postirradiation but was greatly reduced in the ovariectomized control group, with less than half of irradiated eyes showing evidence of cataractogenesis. Thus, after irradiation with 15 Gy of gamma rays, estrogen increased the incidence of cataract formation. We also observed that although the incidence of cataract formation in rats irradiated with 10 Gy and receiving continuous estrogen treatment was not altered compared to rats in the control group that did not receive estrogen, the latent period for posterior subcapsular cataract formation decreased and the severity of the anterior cataract increased. Taken together, our data suggest that estrogen accelerates progression of radiation-induced opacification.
Collapse
Affiliation(s)
- Joseph R Dynlacht
- Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202, USA.
| | | | | | | | | | | | | | | |
Collapse
|