1
|
Abdelkhalek E, Hamama HH, Mahmoud SH. HEMA-free versus HEMA-containing adhesive systems: a systematic review. Syst Rev 2025; 14:17. [PMID: 39838443 PMCID: PMC11748282 DOI: 10.1186/s13643-025-02763-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 01/08/2025] [Indexed: 01/23/2025] Open
Abstract
BACKGROUND Hydrophilic monomer 2-hydroxyethyl methacrylate (HEMA)-free adhesive systems are gaining increasing popularity nowadays. Although the addition of HEMA to dental adhesives improves dentin wettability and resin diffusion into demineralized collagen fibrils, HEMA's high hydrophilicity can lead to hydrolytic degradation of the adhesive interface. Thus, HEMA-free adhesive systems have been developed. Unfortunately, the lack of HEMA in the adhesive composition may lead to a separation phase between hydrophobic and hydrophilic components. The aim of this systematic review was to evaluate the clinical performance of HEMA-free adhesive systems and compare them with HEMA-containing ones. METHODS An electronic search of The National Library of Medicine (MEDLINE/PubMed) was conducted. Eligibility criteria were reporting empirical data from clinical studies published between 2013 and 2023 about the clinical performance of HEMA-free adhesive systems for direct resin composite restorations. Studies with at least 2-year clinical follow-up done in permanent dentition in any form of cavities were selected. The included studies were assessed for risk of bias using the modified Cochrane Collaboration tool criteria. RESULTS The database search returned 147 studies; a total of 7 studies were included in this review; the majority of studies reported no significant difference between the two types of adhesives for the parameter of retention. CONCLUSIONS HEMA-free adhesive systems exhibited good clinical performance with regard to retention. There was some concern about their influence on marginal adaptation and marginal discoloration due to the conflicted results reported by the included trials. Thus, the results need to be confirmed with long-term evaluations. SYSTEMATIC REVIEW REGISTRATION PROSPERO CRD42023448952.
Collapse
Affiliation(s)
- Esraa Abdelkhalek
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Postal Code, 35516, Egypt
| | - Hamdi H Hamama
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Postal Code, 35516, Egypt.
| | - Salah H Mahmoud
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Postal Code, 35516, Egypt
| |
Collapse
|
2
|
Luo X, Rong Q, Luan Q, Yu X. Effect of partial restorative treatment on stress distributions in non-carious cervical lesions: a three-dimensional finite element analysis. BMC Oral Health 2022; 22:607. [PMID: 36522633 PMCID: PMC9753429 DOI: 10.1186/s12903-022-02647-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 12/05/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Partial restoration combined with periodontal root coverage surgery can be applied to the treatment of non-carious cervical lesions (NCCLs) accompanied with gingival recessions in clinical practice. However, the feasibility of NCCL partial restorative treatment from a biomechanical perspective remains unclear. This study aimed to investigate the effect of partial restorations on stress distributions in the NCCLs of mandibular first premolars via three-dimensional finite element analysis. METHODS Three-dimensional finite element models of buccal wedge-shaped NCCLs in various locations of a defected zenith (0 mm, 1 mm, and 2 mm) were constructed and divided into three groups (A, B, and C). Three partially restored NCCL models with different locations of the lower restoration border (1 mm, 1.5 mm, and 2 mm), and one completely restored NCCL model were further constructed for each group. The following restorative materials were used in all restoration models: composite resin (CR), glass-ionomer cement (GIC), and mineral trioxide aggregate (MTA). The first principal stress distributions under buccal oblique loads of 100 N were analyzed. Restoration bond failures were also evaluated based on stress distributions at dentin-restoration interfaces. RESULTS When the partial restoration fully covered the defected zenith, the first principal stress around the zenith decreased and the maximum tensile stress was concentrated at the lower restoration border. When the partial restoration did not cover the defected zenith, the first principal stress distribution patterns were similar to those in unrestored models, with the maximum tensile stress remaining concentrated at the zenith. As the elastic modulus of the restorative material was altered, the stress distributions at the interface were not obviously changed. Restoration bond failures were not observed in CR, but occurred in GIC and MTA in most models. CONCLUSIONS Partial restorations that fully covered defected zeniths improved the stress distributions in NCCLs, while the stress distributions were unchanged or worsened under other circumstances. CR was the optimal material for partial restorations compared to GIC and MTA.
Collapse
Affiliation(s)
- Xin Luo
- grid.11135.370000 0001 2256 9319Department of Periodontology, Peking University School and Hospital of Stomatology, No. 22, Zhongguancun South Avenue, Haidian District, Beijing, 100081 China
| | - Qiguo Rong
- grid.11135.370000 0001 2256 9319Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, China
| | - Qingxian Luan
- grid.11135.370000 0001 2256 9319Department of Periodontology, Peking University School and Hospital of Stomatology, No. 22, Zhongguancun South Avenue, Haidian District, Beijing, 100081 China
| | - Xiaoqian Yu
- grid.11135.370000 0001 2256 9319Department of Periodontology, Peking University School and Hospital of Stomatology, No. 22, Zhongguancun South Avenue, Haidian District, Beijing, 100081 China
| |
Collapse
|
3
|
Da Silva D, Ceballos L, Fuentes MV. Influence of the adhesive strategy in the sealing ability of resin composite inlays after deep margin elevation. J Clin Exp Dent 2021; 13:e886-e893. [PMID: 34603617 PMCID: PMC8464384 DOI: 10.4317/jced.58689] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 07/05/2021] [Indexed: 01/18/2023] Open
Abstract
Background The aim of this study was to determine the influence of the gingival margin position and the adhesive strategy selected to perform deep margin elevation (DME) in marginal sealing of resin composite inlays by a nanoleakage test. Material and Methods 12 sound third molars were selected and expulsive MOD cavities for inlays were prepared. Experimental groups were established according to gingival margin location (enamel: 1 mm above cemento-enamel junction (CEJ), dentin: 1 mm below CEJ, or DME, and the adhesive strategy used to lute inlays and elevate the gingival margin. Therefore, the six experimental groups were: 1) Enamel + etch-and-rinse adhesive (ERA) Adper Scotchbond 1XT (SB1XT); 2) Dentin + SB1XT; 3) DME + SB1XT; 4) Enamel + self-etching adhesive (SEA) with enamel selective etching Clearfil SE Bond (CSE); 5) Dentin + CSE; 6) DME + CSE. Resin composite inlays were constructed (Gradia Indirect) and all luted with the same resin cement (RelyX ARC). Specimens were submitted to nanoleakage test. Results were analyzed by Kruskal-Wallis and Mann-Whitney U tests with Bonferroni correction (p<0.05). Results A perfect sealing ability was evidenced for experimental groups with gingival margins on enamel. Similar nanoleakage values were determined when CSE adhesive was applied regardless the gingival margin position. The highest silver nitrate infiltration was detected for elevated margins with the ERA SB1XT. Conclusions The SEA Clearfil SE Bond showed higher sealing ability than the ERA Adper Scotchbond 1XT when margins were located on dentin, regardless margin elevation. Gingival margins on enamel together with enamel acid etching provided an excellent sealing with both adhesive systems. Key words:Adhesion, composite inlays, gingival margin, deep margin elevation, marginal seal, nanoleakage test.
Collapse
Affiliation(s)
- Dayana Da Silva
- DDS, PhD, Assistant Professor, IDIBO Research Group, Nursing and Stomatology Department, Health Sciences Faculty, Rey Juan Carlos University. Av. de Atenas, S/N, 28922. Alcorcón, Madrid, Spain
| | - Laura Ceballos
- DDS, PhD, Professor, IDIBO Research Group, Nursing and Stomatology Department, Health Sciences Faculty, Rey Juan Carlos University. Av. de Atenas, S/N, 28922. Alcorcón, Madrid, Spain
| | - María-Victoria Fuentes
- DDS, PhD, Associate Professor, IDIBO Research Group, Nursing and Stomatology Department, Health Sciences Faculty, Rey Juan Carlos University. Av. de Atenas, S/N, 28922. Alcorcón, Madrid, Spain
| |
Collapse
|
4
|
Bond stability of conventional adhesive system with MMP inhibitors to superficial and deep dentin. J Mech Behav Biomed Mater 2019; 100:103402. [DOI: 10.1016/j.jmbbm.2019.103402] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 08/13/2019] [Accepted: 08/19/2019] [Indexed: 11/22/2022]
|
5
|
El Mourad AM. Assessment of Bonding Effectiveness of Adhesive Materials to Tooth Structure using Bond Strength Test Methods: A Review of Literature. Open Dent J 2018; 12:664-678. [PMID: 30369976 PMCID: PMC6182887 DOI: 10.2174/1745017901814010664] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 07/30/2018] [Accepted: 09/03/2018] [Indexed: 12/13/2022] Open
Abstract
Background The rapid developments in the field of adhesive dental materials have led to improvements in many aspects of clinical dentistry. Adhesive bond strength plays an important role in determining the clinical performance and longevity of dental restorations. Nevertheless, bond strength tests have never been well-standardized, although a number of important recommendations have been made. Objective The aim of this paper is to critically review the validity of different bond strength testing methods for assessment of bonding effectiveness of adhesive materials to tooth structure and discuss factors that may affect bond strength measurement. Data Collection Relevant literature published between 1983 and 2018 was collected and reviewed from the PubMed database and Google scholar resources. Review Results Results of the current bond testing methods should be used to compare materials tested under the same laboratory settings, but they shouldn't be used to make direct inferences on their clinical behaviour. Shear and micro-shear tests, result in non-uniform stress distribution, stress concentration at the substrate area, and predominantly tensile stresses rather than shear stresses. Micro-tensile bond tests provide many advantages over the shear tests, although these methods are technique sensitive and labour intensive. Conclusion Bond strength testing methods should be well-standardized, but there are many factors that cannot be fully controlled which leads to variation and misinterpretation of the data about the bonding abilities of adhesives. Clinical Significance New adhesive materials should be subjected to a combination of testing protocols to properly assess their bonding effectiveness.
Collapse
Affiliation(s)
- Aminah M El Mourad
- Department of Restorative Dental Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
6
|
The effect of Er:YAG laser irradiation on the bond stability of self-etch adhesives at different dentin depths. Lasers Med Sci 2017; 32:967-974. [PMID: 28357598 PMCID: PMC5486492 DOI: 10.1007/s10103-017-2194-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Accepted: 03/14/2017] [Indexed: 11/20/2022]
Abstract
The aim of this study was to evaluate the effect of Er:YAG laser irradiation on the micro-shear bond strength of self-etch adhesives to the superficial dentin and the deep dentin before and after thermocycling. Superficial dentin and deep dentin surfaces were prepared by flattening of the occlusal surfaces of extracted human third molars. The deep or superficial dentin specimens were randomized into three groups according to the following surface treatments: group I (control group), group II (Er:YAG laser; 1.2 W), and group III (Er:YAG laser; 0.5 W). Clearfil SE Bond or Clearfil S3 Bond was applied to each group’s dentin surfaces. After construction of the composite blocks on the dentin surface, the micro-shear bond testing of each adhesive was performed at 24 h or after 15,000 thermal cycles. The data were analyzed using a univariate analysis of variance and Tukey’s test (p < 0.05). Laser irradiation in superficial dentin did not significantly affect bond strength after thermocycling (p > 0.05). However, deep-dentin specimens irradiated with laser showed significantly higher bond strengths than did control specimens after thermocycling (p < 0.05). Thermocycling led to significant deterioration in the bond strengths of all deep-dentin groups. The stable bond strength after thermocycling was measured for all of the superficial-dentin groups. No significant difference was found between the 0.5 and 1.2 W output power settings. In conclusion, the effect of laser irradiation on the bond strength of self-etch adhesives may be altered by the dentin depth. Regardless of the applied surface treatment, deep dentin showed significant bond degradation.
Collapse
|
7
|
Combined effect of smear layer characteristics and hydrostatic pulpal pressure on dentine bond strength of HEMA-free and HEMA-containing adhesives. J Dent 2013; 41:861-71. [PMID: 23851133 DOI: 10.1016/j.jdent.2013.07.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Revised: 07/01/2013] [Accepted: 07/03/2013] [Indexed: 11/20/2022] Open
Abstract
OBJECTIVE This study evaluated the combined effect of smear layer characteristics with hydrostatic pulpal pressure (PP) on bond strength and nanoleakage expression of HEMA-free and -containing self-etch adhesives. METHODS Flat dentine surfaces were obtained from extracted human molars. Smear layers were created by grinding with #180- or #600-SiC paper. Three HEMA-free adhesives (Xeno V, G Bond Plus, Beautibond Multi) and two HEMA-containing adhesives (Bond Force, Tri-S Bond) were applied to the dentine surfaces under hydrostatic PP or none. Dentine bond strengths were determined using the microtensile bond test (μTBS). Data were statistically analyzed using three- and two-way ANOVA with Tukey post hoc comparison test. Nanoleakage evaluation was carried out under a scanning electron microscope (SEM). RESULTS Coarse smear layer preparation and hydrostatic PP negatively affected the μTBS of HEMA-free and -containing adhesives, but there were no significant differences. The combined experimental condition significantly reduced μTBS of the HEMA-free adhesives, while the HEMA-containing adhesives exhibited no significant differences. Two-way ANOVA indicated that for HEMA-free adhesives, there were significant interactions in μTBS between smear layer characteristics and pulpal pressure, while for HEMA-containing adhesives, there were no significant interactions between them. Nanoleakage formation within the adhesive layers of both adhesive systems distinctly increased in the combined experimental group. CONCLUSION The combined effect of coarse smear layer preparation with hydrostatic PP significantly reduced the μTBS of HEMA-free adhesives, while in HEMA-containing adhesives, these effects were not obvious. CLINICAL SIGNIFICANCE Smear layer characteristics and hydrostatic PP would additively compromise dentine bonding of self-etch adhesives, especially HEMA-free adhesives.
Collapse
|
8
|
Shear bond strengths and morphological evaluation of filled and unfilled adhesive interfaces to enamel and dentine. Int J Dent 2012; 2012:858459. [PMID: 23209471 PMCID: PMC3502849 DOI: 10.1155/2012/858459] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2012] [Revised: 09/24/2012] [Accepted: 09/28/2012] [Indexed: 11/17/2022] Open
Abstract
In this laboratory study shear bond strengths of three filled and one unfilled adhesive systems to enamel and dentine were compared. Forty-eight extracted intact noncarious human mandibular molars were randomly assigned to two groups of 24 one for bonding to enamel and the other for bonding to dentine. Buccal and lingual surfaces of each tooth were randomly assigned for application of each one of filled (Prime & Bond NT (PBNT), Optibond Solo Plus (OBSP), and Clearfil SE Bond (CSEB)) and unfilled (Single Bond (SB)) adhesive systems (n = 12). A universal resin composite was placed into the translucent plastic cylinders (3 mm in diameter and 2 mm in length) and seated against the enamel and dentine surfaces and polymerized for 40 seconds. Shear bond strength was determined using a universal testing machine, and the results were statistically analyzed using two-way ANOVA, one-way ANOVA, t-test, and Tukey HSD post hoc test with a 5% level of significance.There were no statistically significant differences in bond strength between the adhesive systems in enamel, but CSEB and SB exhibited significantly higher and lower bond strength to dentine, respectively, than the other tested adhesive systems while there were no statistically significant differences between PBNT and OBSP.
Collapse
|
9
|
Two-year bond strengths of “all-in-one” adhesives to dentine. J Dent 2012; 40:549-55. [DOI: 10.1016/j.jdent.2012.03.003] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 01/25/2012] [Accepted: 03/09/2012] [Indexed: 11/17/2022] Open
|
10
|
Khoroushi M, Mansoori M. Marginal sealing durability of two contemporary self-etch adhesives. ISRN DENTISTRY 2012; 2012:204813. [PMID: 22611501 PMCID: PMC3350979 DOI: 10.5402/2012/204813] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2011] [Accepted: 01/29/2012] [Indexed: 11/23/2022]
Abstract
Introduction. Sealing abilities of two self-etch adhesives were evaluated after two aging processes: storage in water and thermocycling. Materials and Methods. Cl V cavities were prepared on the buccal and lingual aspects of 48 human premolars, with cervical margins 1 mm below the CEJ. Clearfil Protect Bond (CPB) and BeautiBond (BB) (two-step and one-step self-etch adhesives, resp.) were applied, each to half of the cavities and restored with composite resin. Each group was randomly subdivided into 4 subgroups (n = 12) and evaluated for dye penetration after 24 hours, after 3000 thermocycling rounds, after a 6-month water storage, and after 3000 thermocycling rounds plus 6-month water storage, respectively. Data was analyzed using SPSS 11.5 and Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). Results. There were no significant differences in enamel and dentin microleakage between the adhesives (P = 0.683; P = 0.154). Furthermore, no significant differences were observed in enamel microleakage of each one of CPB and BB (P = 0.061 and P = 0.318, resp.). However, significant decrease was observed in subgroups 3 and 4 (P = 0.001) for CPB dentinal margins. Conclusion. In this study, limited aging procedures had no influence on marginal integrity of composite resin restorations bonded with self-etch adhesives of CPB and BB. Furthermore, CPB dentinal sealing improved after aging.
Collapse
Affiliation(s)
- Maryam Khoroushi
- Dental Materials Research Center and Department of Operative Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Hezar Jerib Street, Isfahan 81746-73461, Iran
| | | |
Collapse
|
11
|
Effect of cavity configuration (C factor) on the marginal adaptation of low-shrinking composite: a comparative ex vivo study. Int J Dent 2011; 2011:159749. [PMID: 21949664 PMCID: PMC3178442 DOI: 10.1155/2011/159749] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2011] [Revised: 07/12/2011] [Accepted: 07/14/2011] [Indexed: 11/19/2022] Open
Abstract
Aim. To investigate the effect of C factor on marginal adaptation of low-shrinking composite (Silorane).The null hypothesis was that the marginal adaptation of “Silorane” is not affected by the cavity configuration. Materials and Methods. A Silorane based and a methacrylate based composites, with their corresponding self-etch adhesive systems “Filtek Silorane/Silorane Adhesive Bond System and Filtek Z250/Prompt L-Pop” respectively were used. Standardized cavities were prepared on the buccal surfaces of 100 maxillary premolars. Teeth were grouped into 5 groups (n = 20), for the 5 C factors. Restored teeth were subjected to thermocycling. Microleakage testing was done and linear dye penetration was assessed using a stereomicroscope. Statistical analysis was done using the Student's t-test. Results. For the methacrylate based systems' overall leakage score was significantly higher than the Silorane-based one (P = 0.034). For the methacrylate-based, leakage was found in all tested teeth groups except group 1 (C factor 1/5). For the Silorane, One-way ANOVA revealed a statistically significant increase in dye penetration in the 5th group (P = 0.010). Conclusions. The null hypothesis was rejected. The Silorane-based resin although it resulted in a statistically significant good marginal adaptation, it showed tendency toward a high leakage score with C-factor of 5.
Collapse
|
12
|
Nikaido T, Inoue G, Takagaki T, Waidyasekera K, Iida Y, Shinohara MS, Sadr A, Tagami J. New strategy to create “Super Dentin” using adhesive technology: Reinforcement of adhesive–dentin interface and protection of tooth structures. JAPANESE DENTAL SCIENCE REVIEW 2011. [DOI: 10.1016/j.jdsr.2010.04.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
13
|
SHINODA Y, NAKAJIMA M, HOSAKA K, OTSUKI M, FOXTON RM, TAGAMI J. Effect of smear layer characteristics on dentin bonding durability of HEMA-free and HEMA-containing one-step self-etch adhesives. Dent Mater J 2011; 30:501-10. [PMID: 21778604 DOI: 10.4012/dmj.2011-001] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
14
|
Van Landuyt K, De Munck J, Mine A, Cardoso M, Peumans M, Van Meerbeek B. Filler Debonding & Subhybrid-layer Failures in Self-etch Adhesives. J Dent Res 2010; 89:1045-50. [PMID: 20631093 DOI: 10.1177/0022034510375285] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The mechanisms behind bond degradation are still largely unknown, in particular with respect to self-etch adhesives. One-step adhesives have been especially documented with problems, such as insufficient polymerization, water-uptake and subsequent plasticization, water- and enzyme-induced nanoleakage, and/or the presence of voids due to phase-separation or osmosis. It was hypothesized that these shortcomings may weaken the adhesive layer and, as such, may jeopardize long-term bonding. In contrast to the control three-step etch & rinse adhesive, the bond strength to dentin of both one-step and two-step self-etch adhesives decreased after six-month water storage. TEM revealed not only that they exhibited filler de-bonding within the adhesive resin layer, due to hydrolysis of the filler-matrix coupling, but also that they failed predominantly directly under the hybrid layer at dentin, in spite of the presence of interfacial droplets and nanoleakage in the adhesive layer. These failures just under the hybrid layer may be attributed to insufficient encapsulation of surface smear.
Collapse
Affiliation(s)
- K.L. Van Landuyt
- Leuven BIOMAT Research Cluster, Department of Conservative Dentistry, School of Dentistry, Oral Pathology and Maxillo-Facial Surgery, Catholic University of Leuven, Kapucijnenvoer 7, B-3000 Leuven, Belgium
| | - J. De Munck
- Leuven BIOMAT Research Cluster, Department of Conservative Dentistry, School of Dentistry, Oral Pathology and Maxillo-Facial Surgery, Catholic University of Leuven, Kapucijnenvoer 7, B-3000 Leuven, Belgium
| | - A. Mine
- Leuven BIOMAT Research Cluster, Department of Conservative Dentistry, School of Dentistry, Oral Pathology and Maxillo-Facial Surgery, Catholic University of Leuven, Kapucijnenvoer 7, B-3000 Leuven, Belgium
| | - M.V. Cardoso
- Leuven BIOMAT Research Cluster, Department of Conservative Dentistry, School of Dentistry, Oral Pathology and Maxillo-Facial Surgery, Catholic University of Leuven, Kapucijnenvoer 7, B-3000 Leuven, Belgium
| | - M. Peumans
- Leuven BIOMAT Research Cluster, Department of Conservative Dentistry, School of Dentistry, Oral Pathology and Maxillo-Facial Surgery, Catholic University of Leuven, Kapucijnenvoer 7, B-3000 Leuven, Belgium
| | - B. Van Meerbeek
- Leuven BIOMAT Research Cluster, Department of Conservative Dentistry, School of Dentistry, Oral Pathology and Maxillo-Facial Surgery, Catholic University of Leuven, Kapucijnenvoer 7, B-3000 Leuven, Belgium
| |
Collapse
|
15
|
Liu HL, Lin CL, Sun MT, Chang YH. 3D micro-crack propagation simulation at enamel/adhesive interface using FE submodeling and element death techniques. Ann Biomed Eng 2010; 38:2004-12. [PMID: 20414728 DOI: 10.1007/s10439-010-0047-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2009] [Accepted: 04/13/2010] [Indexed: 11/29/2022]
Abstract
This study investigates micro-crack propagation at the enamel/adhesive interface using finite element (FE) submodeling and element death techniques. A three-dimensional (3D) FE macro-model of the enamel/adhesive/ceramic subjected to shear bond testing was generated and analyzed. A 3D micro-model with interfacial bonding structure was constructed at the upper enamel/adhesive interface where the stress concentration was found from the macro-model results. The morphology of this interfacial bonding structure (i.e., resin tag) was assigned based on resin tag geometry and enamel rod arrangement from a scanning electron microscopy micrograph. The boundary conditions for the micro-model were determined from the macro-model results. A custom iterative code combined with the element death technique was used to calculate the micro-crack propagation. Parallel experiments were performed to validate this FE simulation. The stress concentration within the adhesive occurred mainly at the upper corner near the enamel/adhesive interface and the resin tag base. A simulated fracture path was found at the resin tag base along the enamel/adhesive interface. A morphological observation of the fracture patterns obtained from in vitro testing corresponded with the simulation results. This study shows that the FE submodeling and element death techniques could be used to simulate the 3D micro-stress pattern and the crack propagation noted at the enamel/adhesive interface.
Collapse
Affiliation(s)
- Heng-Liang Liu
- Department of Mechanical Engineering, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, 33302 Tao-Yuan, Taiwan.
| | | | | | | |
Collapse
|
16
|
Van Landuyt KL, Cardoso MV, De Munck J, Peumans M, Mine A, Lambrechts P, Van Meerbeek B. Optimization of the concentration of photo-initiator in a one-step self-etch adhesive. Dent Mater 2009; 25:982-8. [PMID: 19304315 DOI: 10.1016/j.dental.2009.02.008] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2008] [Accepted: 02/18/2009] [Indexed: 11/30/2022]
Abstract
OBJECTIVES The objective of this study was to determine the optimal concentration of photo-initiator (camphorquinone) in an experimental one-step self-etch adhesive and to investigate the role of the photo-initiator. METHODS Seven experimental one-step adhesives with a varying amount of camphorquinone ranging from 0 to 5.25wt% were prepared. Their micro-tensile bond strength to enamel and dentin was determined. In addition, the bond strength was also determined when the adhesive was not light-cured prior to the application of the composite. SEM and TEM were used for further evaluation of the resultant interfacial ultrastructure. RESULTS The bond strength to enamel was not influenced by the amount of photo-initiator, whereas the bond strength to dentin dropped significantly when concentrations below 0.35wt% camphorquinone were used. Besides phase-separation droplets, electron microscopy revealed the presence of many small droplets at the bottom of the adhesive layer when the adhesive contained no or only a low concentration of initiator, or when the adhesive was not light-cured. SIGNIFICANCE Since polymerization is severely hampered by oxygen inhibition in thin layers, one-step self-etch adhesives depend greatly on the polymerization of the first layer of lining composite to achieve their ultimate mechanical strength. Consequently, the bond strength to enamel is not influenced by the amount of photo-initiator, but on dentin, bond strength is compromised by droplets, probably due to water absorption, and additionally by the negative effect of water on polymerization and by continuing demineralization of unpolymerized acidic monomers. Overall, it was found that minimally 0.7wt% camphorquinone was needed.
Collapse
Affiliation(s)
- Kirsten L Van Landuyt
- Leuven BIOMAT Research Cluster, Department of Conservative Dentistry, School of Dentistry, Oral Pathology and Maxillo-Facial Surgery, Catholic University of Leuven, Kapucijnenvoer 7, BE-3000 Leuven, Belgium.
| | | | | | | | | | | | | |
Collapse
|
17
|
Donovan TE, Becker W, Brodine AH, Burgess JO, Cagna DR, Summitt JB. Annual review of selected dental literature: report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2008; 100:110-41. [PMID: 18672128 DOI: 10.1016/s0022-3913(08)60159-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Terence E Donovan
- Department of Operative Dentistry, University of North Carolina, Chapel Hill, NC 27599-7450, USA. Terry_Donovan @dentistry.unc.edu
| | | | | | | | | | | |
Collapse
|
18
|
Ansari ZJ, Sadr A, Moezizadeh M, Aminian R, Ghasemi A, Shimada Y, Tagami J, Ansari SJ, Moayedi S. Effects of one-year storage in water on bond strength of self-etching adhesives to enamel and dentin. Dent Mater J 2008; 27:266-72. [PMID: 18540402 DOI: 10.4012/dmj.27.266] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this study was to compare the bond strengths of three self-etching materials during one year of storage. Clearfil SE Bond (SE), Clearfil Protect Bond (PB), and Clearfil Tri-S Bond (TS) were used for bonding to dentin and enamel according to manufacturer's instructions. Microshear bond strength values were measured after 24 hours, six months, and one year. Two-way ANOVA showed that the interaction of material type and storage time was significant for dentin. At baseline, SE had the highest bond strength to dentin. There were no significant changes in bond strength for each material during the storage period, except for PB which showed increased bond strength to dentin after one year. All materials performed reliably after one year. However, the antibacterial and fluoride-releasing effects of PB would further contribute to the long-term clinical benefits of this material.
Collapse
Affiliation(s)
- Zahra Jaberi Ansari
- Department of Restorative Dentistry, Dental School, Shahid Beheshti University, M.C., Daneshjou Blvd, Evin, Tehran 19834, Iran
| | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Yuan Y, Shimada Y, Ichinose S, Tagami J. Effect of dentin depth on hybridization quality using different bonding tactics in vivo. J Dent 2007; 35:664-72. [PMID: 17574319 DOI: 10.1016/j.jdent.2007.05.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2007] [Revised: 05/02/2007] [Accepted: 05/03/2007] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES Incomplete resin infiltration and polymerization of adhesive contributed to nanoleakage formation. This study tested the null hypothesis that adoption of different bonding tactics and dentine depth will not affect hybridization quality in vivo. METHODS Class V cavities were prepared on the labial/buccal surface of monkey teeth. They were bonded by Single Bond (a two-step total-etch adhesive), Clearfil SE Bond (a two-step self-etch adhesive), or Clearfil S(3) Bond (an all-in-one self-etch adhesive). Combined nanoleakage analysis and quantitative immunolabeling evaluation were carried out in the hybrid layer formed in both cervical superficial and deep dentine. RESULTS Single Bond showed reticular and spotted nanoleakage while Clearfil SE Bond and Clearfil S(3) Bond presented only a spotted one. While Single Bond showed increased concentration of labeling of type I collagen within the deep part of the hybrid layer, two self-etch adhesives-Clearfil SE Bond and Clearfil S(3) Bond revealed a homogeneous labeling pattern, even if the latter presented a significantly increased labeling index in deep dentine. CONCLUSIONS Different bonding tactics showed different nanoleakage patterns and immunolabeling index, and was influenced by dentine depth at different levels in vivo.
Collapse
Affiliation(s)
- Y Yuan
- Department of Cariology and Operative Dentistry, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
| | | | | | | |
Collapse
|