1
|
Petusseau AF, Ochoa M, Reed M, Doyley MM, Hasan T, Bruza P, Pogue BW. Pressure-enhanced sensing of tissue oxygenation via endogenous porphyrin: Implications for dynamic visualization of cancer in surgery. Proc Natl Acad Sci U S A 2024; 121:e2405628121. [PMID: 39141355 PMCID: PMC11348300 DOI: 10.1073/pnas.2405628121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 06/21/2024] [Indexed: 08/15/2024] Open
Abstract
Fluorescence guidance is routinely used in surgery to enhance perfusion contrast in multiple types of diseases. Pressure-enhanced sensing of tissue oxygenation (PRESTO) via fluorescence is a technique extensively analyzed here, that uses an FDA-approved human precursor molecule, 5-aminolevulinic acid (ALA), to stimulate a unique delayed fluorescence signal that is representative of tissue hypoxia. The ALA precontrast agent is metabolized in most tissues into a red fluorescent molecule, protoporphyrin IX (PpIX), which has both prompt fluorescence, indicative of the concentration, and a delayed fluorescence, that is amplified in low tissue oxygen situations. Applied pressure from palpation induces transient capillary stasis and a resulting transient PRESTO contrast, dominant when there is near hypoxia. This study examined the kinetics and behavior of this effect in both normal and tumor tissues, with a prolonged high PRESTO contrast (contrast to background of 7.3) across 5 tumor models, due to sluggish capillaries and inhibited vasodynamics. This tissue function imaging approach is a fundamentally unique tool for real-time palpation-induced tissue response in vivo, relevant for chronic hypoxia, such as vascular diseases or oncologic surgery.
Collapse
Affiliation(s)
| | - Marien Ochoa
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI53705
| | - Matthew Reed
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI53705
| | - Marvin M. Doyley
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY14627
| | - Tayyaba Hasan
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA02114
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College, Hanover, NH03755
| | - Brian W. Pogue
- Thayer School of Engineering, Dartmouth College, Hanover, NH03755
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI53705
| |
Collapse
|
2
|
Manivasagam SS. Efficacy of near-infrared fluorescence cholangiography using indocyanine green in 21 laparoscopic cholecystectomy: A retrospective study. J Minim Access Surg 2024; 20:237-238. [PMID: 38572840 PMCID: PMC11095805 DOI: 10.4103/jmas.jmas_287_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 09/18/2023] [Indexed: 04/05/2024] Open
|
3
|
Khalaf MH, Abdelrahman H, El-Menyar A, Afifi I, Kloub A, Al-Hassani A, Rizoli S, Al-Thani H. Utility of indocyanine green fluorescent dye in emergency general surgery: a review of the contemporary literature. Front Surg 2024; 11:1345831. [PMID: 38419940 PMCID: PMC10899482 DOI: 10.3389/fsurg.2024.1345831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 01/29/2024] [Indexed: 03/02/2024] Open
Abstract
For decades, indocyanine green (ICG) has been available for medical and surgical use. The indications for ICG use in surgery have expanded where guided surgery directed by fluorescence and near-infrared fluorescent imaging offers numerous advantages. Recently, surgeons have reported using ICG operative navigation in the emergency setting, with fluorescent cholangiography being the most common procedure. The utility of ICG also involves real-time perfusion assessment, such as ischemic organs and limbs. The rising use of ICG in surgery can be explained by the ICG's rapid technological evolution, accuracy, ease of use, and great potential to guide precision surgical diagnosis and management. The review aims to summarize the current literature on the uses of ICG in emergency general surgery. It provides a comprehensive and practical summary of the use of ICG, including indication, route of administration, and dosages. To simplify the application of ICG, we subdivided its use into anatomical mapping and perfusion assessment. Anatomical mapping includes the biliary tree, ureters, and bowel. Perfusion assessment includes bowel, pancreas, skin and soft tissue, and gonads. This review provides a reference to emergency general surgeons to aid in implementing ICG in the emergency setting for more enhanced and safer patient care.
Collapse
Affiliation(s)
| | - Husham Abdelrahman
- Department of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar
| | - Ayman El-Menyar
- Clinical Research, Trauma & Vascular Surgery Section, Hamad Medical Corporation, Doha, Qatar
- Department of Clinical Medicine, Weill Cornell Medicine, Doha, Qatar
| | - Ibrahim Afifi
- Department of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar
| | - Ahmad Kloub
- Department of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar
| | - Ammar Al-Hassani
- Department of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar
| | - Sandro Rizoli
- Department of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar
| | - Hassan Al-Thani
- Department of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar
| |
Collapse
|
4
|
Pogue BW, Zhu TC, Ntziachristos V, Wilson BC, Paulsen KD, Gioux S, Nordstrom R, Pfefer TJ, Tromberg BJ, Wabnitz H, Yodh A, Chen Y, Litorja M. AAPM Task Group Report 311: Guidance for performance evaluation of fluorescence-guided surgery systems. Med Phys 2024; 51:740-771. [PMID: 38054538 DOI: 10.1002/mp.16849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 11/02/2023] [Accepted: 11/06/2023] [Indexed: 12/07/2023] Open
Abstract
The last decade has seen a large growth in fluorescence-guided surgery (FGS) imaging and interventions. With the increasing number of clinical specialties implementing FGS, the range of systems with radically different physical designs, image processing approaches, and performance requirements is expanding. This variety of systems makes it nearly impossible to specify uniform performance goals, yet at the same time, utilization of different devices in new clinical procedures and trials indicates some need for common knowledge bases and a quality assessment paradigm to ensure that effective translation and use occurs. It is feasible to identify key fundamental image quality characteristics and corresponding objective test methods that should be determined such that there are consistent conventions across a variety of FGS devices. This report outlines test methods, tissue simulating phantoms and suggested guidelines, as well as personnel needs and professional knowledge bases that can be established. This report frames the issues with guidance and feedback from related societies and agencies having vested interest in the outcome, coming from an independent scientific group formed from academics and international federal agencies for the establishment of these professional guidelines.
Collapse
Affiliation(s)
- Brian W Pogue
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - Timothy C Zhu
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Vasilis Ntziachristos
- Institute for Biological and Medical Imaging, Technical University of Munich, Helmholtz Zentrum Munich, Munich, Germany
| | - Brian C Wilson
- Department of Medical Biophysics, University of Toronto, University Health Network, Toronto, Ontario, Canada
| | - Keith D Paulsen
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - Sylvain Gioux
- Department of Biomedical Engineering, University of Strasbourg, Strasbourg, France
| | - Robert Nordstrom
- Cancer Imaging Program, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - T Joshua Pfefer
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Bruce J Tromberg
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA
| | | | - Arjun Yodh
- Department of Physics, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Yu Chen
- Department of Biomedical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts, USA
| | - Maritoni Litorja
- Sensor Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| |
Collapse
|
5
|
Huang J, Hu W, Liu J, Tang X, Fan Y, Ran L, Li B, Zhang J, Xiong H, Li W, Liang B, Fang L, Fu X. Real-time fluorescence imaging with indocyanine green during laparoscopic duodenum-preserving pancreatic head resection. Pancreatology 2024; 24:130-136. [PMID: 38016861 DOI: 10.1016/j.pan.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 11/12/2023] [Accepted: 11/13/2023] [Indexed: 11/30/2023]
Abstract
BACKGROUND Laparoscopic duodenum-preserving pancreatic head resection (LDPPHR) is a surgical method used to treat benign and low-grade malignant pancreatic head tumors. This study aimed to determine the protective effect of common bile duct in LDPPHR using indocyanine green (ICG) fluorescence imaging. METHODS A retrospective analysis of 30 patients treated with LDPPHR at the Second Affiliated Hospital of Nanchang University between January 2015 and November 2022 was performed. Patients were divided into two groups based on ICG use: ICG and non-ICG. RESULTS Thirty patients received LDPPHR, 11 males and 19 females, and the age was 50.50 (M (IQR)) years (range: 19-76 years). LDPPHR was successfully performed in 27 (90 %) patients, LPD was performed in 1 (3 %) patient, and laparotomy conversion was performed in 2 (7 %) patients. One patient (3 %) died 21 days after surgery. The incidence of intraoperative bile duct injury in the ICG group was lower than that in the non-ICG group (10 % vs 60 %, P = 0.009), and the operation time in the ICG group was shorter than that in the non-ICG group (311.9 ± 14.97 vs 338.05 ± 18.75 min, P < 0.05). Postoperative pancreatic fistula occurred in 16 patients (53 %), including 10 with biochemical leakage (62.5 %), four with grade B (25 %), and two with grade C (12.5 %). Postoperative bile leakage occurred in four patients (13 %). CONCLUSIONS The ICG fluorescence imaging technology in LDPPHR helps protect the integrity of the common bile duct and reduce the occurrence of intraoperative bile duct injury, postoperative bile leakage, and bile duct stenosis.
Collapse
Affiliation(s)
- Jian Huang
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Wei Hu
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Jinghang Liu
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Xinguo Tang
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Yuting Fan
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Longjian Ran
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Bowen Li
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Jia Zhang
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Hu Xiong
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Wen Li
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Bo Liang
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China
| | - Lu Fang
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China.
| | - Xiaowei Fu
- Department of General Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University School of Medicine, Jiangxi, China.
| |
Collapse
|
6
|
Zhu C, Zeitouni F, Vaughan J, Santos AP. Laparoscopic management of combined cholecystogastric and cholecystocolonic fistulae. BMJ Case Rep 2023; 16:e255951. [PMID: 37558278 PMCID: PMC10414080 DOI: 10.1136/bcr-2023-255951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2023] Open
Abstract
Cholecystogastric and cholecystocolonic fistulae are rare sequelae of longstanding cholelithiasis and can complicate surgical management. Our case involves a male patient in his early 40s with a history of chronic cholelithiasis who presented to the emergency department with severe abdominal pain. Findings on imaging were consistent with acute calculous cholecystitis. During laparoscopic cholecystectomy, the presence of both cholecystogastric and cholecystocolonic fistulae was discovered. Fistula resection with cholecystectomy in a one-step approach using indocyanine green (ICG) angiography was performed. The patient improved and was discharged 3 days later. Laparoscopic management complemented by ICG angiography is a viable surgical approach in patients with cholecystogastric and cholecystocolonic fistulae.
Collapse
Affiliation(s)
- Christina Zhu
- Surgery, Texas Tech University Health Sciences Center, Lubbock, Texas, USA
| | - Ferris Zeitouni
- Surgery, Texas Tech University Health Sciences Center, Lubbock, Texas, USA
| | - Justin Vaughan
- Surgery, Texas Tech University Health Sciences Center, Lubbock, Texas, USA
- Covenant Medical Center, Lubbock, Texas, USA
| | - Ariel P Santos
- Surgery, Texas Tech University Health Sciences Center, Lubbock, Texas, USA
- Covenant Medical Center, Lubbock, Texas, USA
| |
Collapse
|
7
|
Piccolo G, Barabino M, Lecchi F, Formisano G, Salaj A, Piozzi GN, Bianchi PP. Utility of near infrared fluorescent cholangiography in detecting biliary structures during challenging minimally invasive cholecystectomy. Langenbecks Arch Surg 2023; 408:282. [PMID: 37462733 DOI: 10.1007/s00423-023-02995-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 06/17/2023] [Indexed: 07/21/2023]
Abstract
BACKGROUND Surgeons can minimize the risk of bile duct injury (BDI) during challenging mini-invasive cholecystectomy through technical standardization by means of a precise anatomical landmark identification (Critical View of Safety) and advanced technology for biliary visualization. Among these systems, the adoption of magnified stereoscopic 3-dimensional view provided by robotic platforms and near infrared fluorescent cholangiography (NIRF-C) is the most promising. METHODS In this prospective cohort study, we evaluated all consecutive minimally invasive cholecystectomies (laparoscopic and robotic) performed with NIRF-C between May 2022 and January 2023 at General Surgery Unit, Department of Health Sciences, University of Milan, San Paolo Hospital (Milan, Italy). Inclusions criteria were as follows: (1) acute cholecystitis (emergency group), (2) history of chronic cholecystitis or complicated cholelithiasis (deferred urgent group), (3) difficult cases (patients affected by cirrhosis, with scleroatrophic gallbladder or BMI > 35 kg/m2). For each group, the detection rate and visualization order of the main biliary structures were reported (cystic duct, CD; common hepatic duct, CHD; common bile duct, CBD; and CD-CHD junction). RESULTS A total of 101 consecutive patients were enrolled, including 83 laparoscopic and 18 robotic cholecystectomies. All patients were stratified into three subgroups: (a) emergency group (n = 33, 32.7%), (b) deferred urgent group (n = 46, 45.5%), (c) difficult group (n = 22, 21.8%). Visualization of at least one biliary structure was possible in 94.1% of cases (95/101). Interestingly, all four main structures were detected in 43.6% of cases (44/101). The CD was the structure identified most frequently, being recognized in 91/101 patients (90.1%), followed by CBD (83.2%), CHD (62.4%), and CD-CHD junction (52.5%). In the subset of patients that underwent emergency surgery for AC, the CD-CHD confluence was identified in only 45.5% of cases. However, early and precise identification of CBD (75.8%) and CD (87.9%) allowed safe isolation, clipping, and transection of the cystic duct. In the deferred urgent group, the CBD and the CD were easily identified as first structure in a high percentage of cases (65.2% and 41.3% respectively), whereas the CD-CHD junction was the third structure to be identified in 67.4% of cases, the highest value among the three subgroups. In the difficult group, NIRF-C did not prove to be a useful tool for biliary visualization. The rates of failure of visualization were elevated: CBD (27.3%), CD (18.2%), CHD (54.5%), and CD-CHD (68.2%). CONCLUSIONS NIRF-C is a powerful real-time diagnostic tool to detect CBD and CD during minimally invasive cholecystectomy, especially when inflammation due to acute or chronic cholecystitis subverted the anatomy of the hepatoduodenal ligament.
Collapse
Affiliation(s)
- Gaetano Piccolo
- General Surgery Unit, Department of Health Sciences (DISS), University of Milan, San Paolo Hospital, Via Antonio Di Rudinì 8, Milan, 20142, Italy.
| | - Matteo Barabino
- General Surgery Unit, Department of Health Sciences (DISS), University of Milan, San Paolo Hospital, Via Antonio Di Rudinì 8, Milan, 20142, Italy
| | - Francesca Lecchi
- General Surgery Unit, Department of Health Sciences (DISS), University of Milan, San Paolo Hospital, Via Antonio Di Rudinì 8, Milan, 20142, Italy
| | - Giampaolo Formisano
- General Surgery Unit, Department of Health Sciences (DISS), University of Milan, San Paolo Hospital, Via Antonio Di Rudinì 8, Milan, 20142, Italy
| | - Adelona Salaj
- General Surgery Unit, Department of Health Sciences (DISS), University of Milan, San Paolo Hospital, Via Antonio Di Rudinì 8, Milan, 20142, Italy
| | | | - Paolo Pietro Bianchi
- General Surgery Unit, Department of Health Sciences (DISS), University of Milan, San Paolo Hospital, Via Antonio Di Rudinì 8, Milan, 20142, Italy
| |
Collapse
|
8
|
Di Mitri M, Thomas E, Di Carmine A, Manghi I, Cravano SM, Bisanti C, Collautti E, Ruspi F, Cordola C, Vastano M, D'Antonio S, Libri M, Gargano T, Lima M. Intraoperative Ultrasound in Minimally Invasive Laparoscopic and Robotic Pediatric Surgery: Our Experiences and Literature Review. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1153. [PMID: 37508649 PMCID: PMC10378675 DOI: 10.3390/children10071153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Revised: 06/12/2023] [Accepted: 06/27/2023] [Indexed: 07/30/2023]
Abstract
Ultrasound (US) is a non-invasive imaging technique frequently used to examine internal organs and superficial tissues, and invaluable in pediatric patients. In a surgical setting, intraoperative ultrasound allows to highlight anatomical structures in detail during traditional open and minimally invasive surgery, thanks to the use of specific probes. In fact, laparoscopic and robotic ultrasonography requires the development of specialized transducers that fit through laparoscopic trocars. In adults, laparoscopic ultrasound is used during cholecystectomy before dissection of the triangle of Calot, to guide liver biopsies and ablation procedures and for the staging of patients with pancreas adenocarcinoma. However, the applications in the pediatric field are still limited. This paper aims to share our preliminary experience with ultra-sound in minimally invasive laparoscopic and robotic pediatric surgery, describing two cases in which intra-operative ultrasound was applied, and to present a review of the literature on the state of the art of the actual uses in pediatric surgery.
Collapse
Affiliation(s)
- Marco Di Mitri
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Eduje Thomas
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Annalisa Di Carmine
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Ilaria Manghi
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Sara Maria Cravano
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Cristian Bisanti
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Edoardo Collautti
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Francesca Ruspi
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Chiara Cordola
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Marzia Vastano
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Simone D'Antonio
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Michele Libri
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Tommaso Gargano
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| | - Mario Lima
- Pediatric Surgery Department, IRCCS Sant'Orsola-Malpighi Polyclinic, Alma Mater Studiorum-University of Bologna, 40126 Bologna, Italy
| |
Collapse
|
9
|
Potharazu AV, Gangemi A. Indocyanine green (ICG) fluorescence in robotic hepatobiliary surgery: A systematic review. Int J Med Robot 2023; 19:e2485. [PMID: 36417426 PMCID: PMC10078519 DOI: 10.1002/rcs.2485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 11/08/2022] [Accepted: 11/21/2022] [Indexed: 11/25/2022]
Abstract
BACKGROUND Indocyanine green fluorescence (ICG-F) stains hepatic tumours and delineates vascular and biliary structures in real-time. We detail the efficacy of ICG-F in robotic hepatobiliary surgery. METHODS PubMed, EMBASE, Web of Science, and Cochrane Central were searched for original articles and meta-analyses detailing the outcomes of ICG-F in robotic hepatobiliary surgery. RESULTS 214 abstracts were reviewed; 16 studies are presented. One single-institution study reported ICG-F in robotic right hepatectomy reduced postoperative bile leakage (0% vs. 12%, p = 0.023), R1 resection (0% vs. 16%, p = 0.019), and readmission (p = 0.023) without prolonging operative time (288 vs. 272 min, p = 0.778). Improved visualisation aided in attainment of R0 resection in partial hepatectomies and radical gallbladder adenocarcinoma resections. Fewer ICG-F-aided robotic cholecystectomies were converted to open procedure compared to laparoscopic cholecystectomies (2.1% vs. 8.9%, p = 0.03; 0.15% vs. 2.6%, p < 0.001). CONCLUSIONS ICG-F improves clinical outcomes in robotic hepatobiliary surgery without prolonging operative time. There is an opportunity to standardise ICG administration protocols, especially for hepatectomies.
Collapse
Affiliation(s)
| | - Antonio Gangemi
- Department of Medical and Surgical SciencesAlma Mater Studiorum University of Bologna, Policlinico Sant’Orsola IRCCSBolognaItaly
| |
Collapse
|
10
|
Zagainov EV, Karachun AM, Sapronov PA, Khromova EA, Kazantsev AI. [Modern possibilities of fluorescent imaging in liver surgery]. Khirurgiia (Mosk) 2023:98-106. [PMID: 37916563 DOI: 10.17116/hirurgia202310198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
The article presents a literature review of modern methods of fluorescent navigation in liver surgery. The technique of tumor «staining», mapping of liver segments, fluorescent cholangiography is covered. The own results of the use of indocyanine green in liver surgery are presented.
Collapse
Affiliation(s)
- E V Zagainov
- FSBI «National Medical Research Center of Oncology named after N.N. Petrov» of the Ministry of Health of Russia, St. Petersburg, Russia
| | - A M Karachun
- FSBI «National Medical Research Center of Oncology named after N.N. Petrov» of the Ministry of Health of Russia, St. Petersburg, Russia
| | - P A Sapronov
- FSBI «National Medical Research Center of Oncology named after N.N. Petrov» of the Ministry of Health of Russia, St. Petersburg, Russia
| | - E A Khromova
- FSBI «National Medical Research Center of Oncology named after N.N. Petrov» of the Ministry of Health of Russia, St. Petersburg, Russia
| | - A I Kazantsev
- FSBI «National Medical Research Center of Oncology named after N.N. Petrov» of the Ministry of Health of Russia, St. Petersburg, Russia
| |
Collapse
|
11
|
A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery. Surgery 2023; 173:132-137. [PMID: 36511281 DOI: 10.1016/j.surg.2022.07.057] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 06/24/2022] [Accepted: 07/19/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND The usefulness of incorporating near-infrared autofluorescence into the surgical workflow of endocrine surgeons is unclear. Our aim was to develop a prospective registry and gather expert opinion on appropriate use of this technology. METHODS This was a prospective multicenter collaborative study of patients undergoing thyroidectomy and parathyroidectomy at 7 academic centers. A questionnaire was disseminated among 24 participating surgeons. RESULTS Overall, 827 thyroidectomy and parathyroidectomy procedures were entered into registry: 42% of surgeons found near-infrared autofluorescence useful in identifying parathyroid glands before they became apparent; 67% correlated near-infrared autofluorescence pattern to normal and abnormal glands; 38% of surgeons used near-infrared autofluorescence, rather than frozen section, to confirm parathyroid tissue; and 87% and 78% of surgeons reported near-infrared autofluorescence did not improve the success rate after parathyroidectomy or the ability to find ectopic glands, respectively. During thyroidectomy, 66% of surgeons routinely used near-infrared autofluorescence to rule out inadvertent parathyroidectomy. However, only 36% and 45% felt near-infrared autofluorescence decreased inadvertent parathyroidectomy rates and improved ability to preserve parathyroid glands during central neck dissections, respectively. CONCLUSION This survey study identified areas of greatest potential use for near-infrared autofluorescence, which can form the basis of future objective trials to document the usefulness of this technology.
Collapse
|
12
|
Kashchenko VA, Emelyanov SI, Strizheletsky VV, Kossovich MA, Tariverdiev ML, Rutenburg GM, Bogatikov AA, Lodygin AV, Gornov SV, Sultanova FM. [Integration of ICG-fluorescence cholangiography into the safety system of laparoscopic cholecystectomy]. Khirurgiia (Mosk) 2023:89-98. [PMID: 38010022 DOI: 10.17116/hirurgia202311189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2023]
Abstract
THE AIM OF THE STUDY Is evaluating the possibility of integrating ICG-fluorescent cholangiography into the general safety system for laparoscopic cholecystectomy to prevent damage to the extrahepatic bile ducts by working out the methodological aspects of navigation technologies. MATERIALS AND METHODS The analysis of literature data on various approaches to improve the perioperative identification of anatomical structures during laparoscopic cholecystectomy, including the ICG-fluorescent cholangiography, was carried out. This program was implemented during the provision of elective surgical care to 24 patients with cholelithiasis who underwent laparoscopic cholecystectomy with ICG-fluorescent navigation. RESULTS AND DISCUSSION The developed program included: preoperative assessment of the anatomy of the biliary tree using MRCP; intraoperative technique of safe laparoscopic cholecystectomy with mandatory application of the concept of «critical view of safety» (CVS), which allows the most effective identification of the necessary anatomical structures; the use of ICG-fluorescent cholangiography, which allows to improve the control of anatomical structures at all stages of the operations. CONCLUSIONS The first experience of using ICG-fluorescent cholangiography testifies to the high informative value of the method, the possibility and prospects of integrating the technology into a comprehensive safety system during laparoscopic cholecystectomy.
Collapse
Affiliation(s)
- V A Kashchenko
- North-Western district scientific and clinical center named after L.G. Sokolov Federal Medical and Biological Agency, St. Petersburg, Russia
- Saint-Petersburg State University, St. Petersburg, Russia
| | - S I Emelyanov
- Evdokimov Moscow State University of Medicine and Dentistry, Moscow, Russia
| | - V V Strizheletsky
- Saint-Petersburg State University, St. Petersburg, Russia
- St George Martyr Municipal Hospital, St. Petersburg, Russia
| | | | | | - G M Rutenburg
- St George Martyr Municipal Hospital, St. Petersburg, Russia
| | - A A Bogatikov
- North-Western district scientific and clinical center named after L.G. Sokolov Federal Medical and Biological Agency, St. Petersburg, Russia
- Saint-Petersburg State University, St. Petersburg, Russia
| | - A V Lodygin
- North-Western district scientific and clinical center named after L.G. Sokolov Federal Medical and Biological Agency, St. Petersburg, Russia
- Saint-Petersburg State University, St. Petersburg, Russia
| | - S V Gornov
- Russian Biotechnological University (BIOTECH University), Moscow, Russia
| | - F M Sultanova
- St George Martyr Municipal Hospital, St. Petersburg, Russia
| |
Collapse
|
13
|
Patankar R, Mishra RK, Bindal V, Kothari CP, Rahate P, Patnaik S, Kankaria J, Nayak SR. Efficacy of near-infrared fluorescence cholangiography using indocyanine green in laparoscopic cholecystectomy: A retrospective study. J Minim Access Surg 2023; 19:57-61. [PMID: 36722531 PMCID: PMC10034797 DOI: 10.4103/jmas.jmas_369_21] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 02/16/2022] [Accepted: 03/31/2022] [Indexed: 02/03/2023] Open
Abstract
Context While laparoscopy has been the standard procedure for gallstone treatment, recent advances including the use of indocyanine green (ICG) in laparoscopic cholecystectomy have made it easier to understand the biliary tree and reduce the risk of bile duct injury. Aims In this retrospective study, we aim to determine the efficacy of ICG in near-infrared fluorescence cholangiography (NIRFC) for visualising biliary anatomy. Settings and Design A total of 90 patients with the symptoms of cholelithiasis were enrolled for this retrospective study. Subjects and Methods All the patients underwent cholecystectomy approximately 53.8 min (40-90 min) after the intravenous administration of mean volume 1.6 ml (1-2 ml) ICG. The surgeons used NIRFC along with ICG for real-time visualisation of biliary anatomy. Results The mean operative time for the surgery was 65.7 min (25-120 min) with no post-surgical complications observed in the patients. The average length of stay was 2 days (1-3 days). ICG usage with NIRFC enabled identification of cystic duct, common hepatic and common bile duct, the junction between common hepatic and bile duct, right and left hepatic duct in 87.7%, 94.4%, 80% and 14.4% of cases, respectively. Conclusions ICG fluorescence allowed successful visualisation of at least 1 biliary structure in 100% of cases.
Collapse
Affiliation(s)
- Roy Patankar
- Department of General Surgery, World Laparoscopy Hospital, Delhi NCR, Gurgaon, Haryana, India
| | - R. K. Mishra
- Department of General Surgery, Zen Multispecialty Hospital, Mumbai, Maharashtra, India
| | - Vivek Bindal
- Department of General Surgery, Max Super Specialty Hospital, New Delhi, India
| | - C. P. Kothari
- Department of General Surgery, CHL Apollo Hospital, Indore, Madhya Pradesh, India
| | - Prashant Rahate
- Department of General Surgery, Rahate Surgical Hospital, Nagpur, Maharashtra, India
| | - Sreejoy Patnaik
- Department of General Surgery, Shanti Memorial Hospital, Cuttack, Odisha, India
| | - Jeevan Kankaria
- Department of General Surgery, SMS Hospital, Jaipur, Rajasthan, India
| | - Samir Ranjan Nayak
- Department of General Surgery, GSL Medical College and General Hospital, Rajahmundry, Andhra Pradesh, India
| |
Collapse
|
14
|
Omori T, Hara H, Shinno N, Yamamoto M, Kanemura T, Takeoka T, Akita H, Wada H, Yasui M, Matsuda C, Nishimura J, Ohue M, Sakon M, Miyata H. Safety and efficacy of preoperative indocyanine green fluorescence marking in laparoscopic gastrectomy for proximal gastric and esophagogastric junction adenocarcinoma (ICG MAP study). Langenbecks Arch Surg 2022; 407:3387-3396. [PMID: 36227384 DOI: 10.1007/s00423-022-02680-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Accepted: 09/12/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE The incidence of adenocarcinoma of the esophagogastric junction (AEG) and proximal gastric cancer (PGC) is rising worldwide. Recently, the use of indocyanine green (ICG) tracer-guided surgery has been reported; however, its efficacy for total/proximal gastrectomy has not been clarified. We evaluated the feasibility and safety of ICG fluorescent marking for tumor localization in AEG/PGC treatment by laparoscopic surgery. METHODS We enrolled patients with AEG/PGC from October 2016 to March 2019 from a prospectively registered database. On the day before surgery, ICG markings were made at four locations just at the edge of the tumor by gastrointestinal fiberscope examination. Surgery was performed while viewing the fluorescence image of ICG, and the proximal portions of the esophagus and the distal portion of the stomach were resected at the edge of the area where ICG had spread. RESULTS We enrolled 130 patients with AEG/PGC. Overall, 107 patients were eventually included in the study: AEG n = 64 (60%) and PGC n = 43 (40%). ICG markings were detected intraoperatively in all cases, and cancer invasion into the resection lines of the esophagus and stomach, performed based on ICG fluorescence images, was negative in all cases. The median visible range of ICG fluorescence was 22.5 mm. ICG diffusion expanded 20 mm proximal for AEG. There were no adverse events associated with endoscopic ICG injection. CONCLUSION ICG fluorescence imaging is feasible and safe and can potentially be used as a tumor-marking agent for determining the surgical resection line for total/proximal gastrectomy in AEG and PGC treatment.
Collapse
Affiliation(s)
- Takeshi Omori
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan.
| | - Hisashi Hara
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Naoki Shinno
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Masaaki Yamamoto
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Takashi Kanemura
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Tomohira Takeoka
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Hirofumi Akita
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Hiroshi Wada
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Masayoshi Yasui
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Chu Matsuda
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Junichi Nishimura
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Masayuki Ohue
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Masato Sakon
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| | - Hiroshi Miyata
- Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Japan
| |
Collapse
|
15
|
Pavone G, Fersini A, Pacilli M, De Fazio M, Panzera P, Ambrosi A, Tartaglia N. Can indocyanine green during laparoscopic sleeve gastrectomy be considered a new intraoperative modality for leak testing? BMC Surg 2022; 22:341. [PMID: 36114496 PMCID: PMC9482312 DOI: 10.1186/s12893-022-01796-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 09/14/2022] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Indocyanine green (ICG) when injected intravenously into the bloodstream allows us to show stomach vascularity in real time. The aim of our study was to observe the preliminary results of the application of indocyanine green fluorescence (IGF) during laparoscopic sleeve gastrectomy (LSG) in our center and how the perfusion of the staple line of the stomach affects the onset of fistula. MATERIALS AND METHODS 82 patients underwent LSG with ICG fluorescence angiography at our center from January 2020 to December 2021. 5 ml of ICG was injected intravenously to identify the blood supply of the stomach, carefully assessing the angle of His. RESULTS In the ICG-tested LSG, we recorded adequate perfusion in all patients but one: the leakage rate was 1.2%. This data is inferior to the non-tested patients' group. CONCLUSION Intraoperative ICG testing may be helpful in determining which patients are at an increased risk for leakage but there are multiple factors contribute to the pathophysiology and the incidence of gastric fistula not only the perfusion. Trial registration Retrospectively registrated.
Collapse
Affiliation(s)
- Giovanna Pavone
- Department of Medical and Surgical Sciences, University of Foggia, Viale Pinto 1, 71122 Foggia, Italy
| | - Alberto Fersini
- Department of Medical and Surgical Sciences, University of Foggia, Viale Pinto 1, 71122 Foggia, Italy
| | - Mario Pacilli
- Department of Medical and Surgical Sciences, University of Foggia, Viale Pinto 1, 71122 Foggia, Italy
| | - Michele De Fazio
- Department of General Surgery and Liver Transplantation, University of Bari, 70124 Bari, Italy
| | - Piercarmine Panzera
- Department of General Surgery and Liver Transplantation, University of Bari, 70124 Bari, Italy
| | - Antonio Ambrosi
- Department of Medical and Surgical Sciences, University of Foggia, Viale Pinto 1, 71122 Foggia, Italy
| | - Nicola Tartaglia
- Department of Medical and Surgical Sciences, University of Foggia, Viale Pinto 1, 71122 Foggia, Italy
| |
Collapse
|
16
|
Chandhok S, Chao P, Koea J, Srinivasa S. Robotic-assisted cholecystectomy: Current status and future application. LAPAROSCOPIC, ENDOSCOPIC AND ROBOTIC SURGERY 2022. [DOI: 10.1016/j.lers.2022.06.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
|
17
|
Morales-Conde S, Licardie E, Alarcón I, Balla A. Indocyanine green (ICG) fluorescence guide for the use and indications in general surgery: recommendations based on the descriptive review of the literature and the analysis of experience. Cir Esp 2022; 100:534-554. [PMID: 35700889 DOI: 10.1016/j.cireng.2022.06.023] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 11/26/2021] [Indexed: 06/15/2023]
Abstract
Indocyanine Green is a fluorescent substance visible in near-infrared light. It is useful for the identification of anatomical structures (biliary tract, ureters, parathyroid, thoracic duct), the tissues vascularization (anastomosis in colorectal, esophageal, gastric, bariatric surgery, for plasties and flaps in abdominal wall surgery, liver resection, in strangulated hernias and in intestinal ischemia), for tumor identification (liver, pancreas, adrenal glands, implants of peritoneal carcinomatosis, retroperitoneal tumors and lymphomas) and sentinel node identification and lymphatic mapping in malignant tumors (stomach, breast, colon, rectum, esophagus and skin cancer). The evidence is very encouraging, although standardization of its use and randomized studies with higher number of patients are required to obtain definitive conclusions on its use in general surgery. The aim of this literature review is to provide a guide for the use of ICG fluorescence in general surgery procedures.
Collapse
Affiliation(s)
- Salvador Morales-Conde
- Unit of Innovation in Minimally Invasive Surgery, Department of General and Digestive Surgery, University Hospital Virgen del Rocio, University of Sevilla, Sevilla, Spain; Unit of General and Digestive Surgery, Hospital Quironsalud Sagrado Corazón, Sevilla, Spain.
| | - Eugenio Licardie
- Unit of General and Digestive Surgery, Hospital Quironsalud Sagrado Corazón, Sevilla, Spain.
| | - Isaias Alarcón
- Unit of Innovation in Minimally Invasive Surgery, Department of General and Digestive Surgery, University Hospital Virgen del Rocio, University of Sevilla, Sevilla, Spain.
| | - Andrea Balla
- Unit of Innovation in Minimally Invasive Surgery, Department of General and Digestive Surgery, University Hospital Virgen del Rocio, University of Sevilla, Sevilla, Spain; UOC of General and Minimally Invasive Surgery, Hospital "San Paolo", Civitavecchia, Rome, Italy.
| |
Collapse
|
18
|
Reinisch A, Liese J, Padberg W, Ulrich F. Robotic operations in urgent general surgery: a systematic review. J Robot Surg 2022; 17:275-290. [PMID: 35727485 PMCID: PMC10076409 DOI: 10.1007/s11701-022-01425-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 05/06/2022] [Indexed: 12/07/2022]
Abstract
Robotically assisted operations are the state of the art in laparoscopic general surgery. They are established predominantly for elective operations. Since laparoscopy is widely used in urgent general surgery, the significance of robotic assistance in urgent operations is of interest. Currently, there are few data on robotic-assisted operations in urgent surgery. The aim of this study was to collect and classify the existing studies. A two-stage, PRISMA-compliant literature search of PubMed and the Cochrane Library was conducted. We analyzed all articles on robotic surgery associated with urgent general surgery resp. acute surgical diseases of the abdomen. Gynecological and urological diseases so as vascular surgery, except mesenterial ischemia, were excluded. Studies and case reports/series published between 1980 and 2021 were eligible for inclusion. In addition to a descriptive synopsis, various outcome parameters were systematically recorded. Fifty-two studies of operations for acute appendicitis and cholecystitis, hernias and acute conditions of the gastrointestinal tract were included. The level of evidence is low. Surgical robots in the narrow sense and robotic camera mounts were used. All narrow-sense robots are nonautonomous systems; in 82%, the Da Vinci® system was used. The most frequently published emergency operations were urgent cholecystectomies (30 studies, 703 patients) followed by incarcerated hernias (9 studies, 199 patients). Feasibility of robotic operations was demonstrated for all indications. Neither robotic-specific problems nor extensive complication rates were reported. Various urgent operations in general surgery can be performed robotically without increased risk. The available data do not allow a final evidence-based assessment.
Collapse
Affiliation(s)
- Alexander Reinisch
- Department of General, Visceral and Oncologic Surgery, Wetzlar Hospital and Clinics, Forsthausstr. 1, 35578, Wetzlar, Germany.
| | - Juliane Liese
- Department of General, Visceral, Thoracic, Transplant and Pediatric Surgery, University Hospital Giessen, Giessen, Germany
| | - Winfried Padberg
- Department of General, Visceral, Thoracic, Transplant and Pediatric Surgery, University Hospital Giessen, Giessen, Germany
| | - Frank Ulrich
- Department of General, Visceral and Oncologic Surgery, Wetzlar Hospital and Clinics, Forsthausstr. 1, 35578, Wetzlar, Germany
| |
Collapse
|
19
|
Alghoul H, Farajat FA, Alser O, Snyr AR, Harmon CM, Novotny NM. Intraoperative uses of near-infrared fluorescence spectroscopy in pediatric surgery: A systematic review. J Pediatr Surg 2022; 57:1137-1144. [PMID: 35256157 DOI: 10.1016/j.jpedsurg.2022.01.039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 01/22/2022] [Indexed: 11/25/2022]
Abstract
BACKGROUND The application of near infrared spectroscopy (NIRS) imaging in surgery is growing. This study aimed to systematically review the literature to summarize the intraoperative uses of NIRS in pediatric surgery. METHODS A PRISMA-compliant literature search was conducted in PubMed, Embase, Scopus, and Web of Science from inception to February 2020. Title/abstract and then full-text screening were performed. The Oxford centre for Evidence Based Medicine tool (OCEBM) was used to evaluate the level of evidence of included studies. RESULTS Reviewers identified 53 articles. Of which, 34 studies (64.2%) were case-series and 11 (20.8%) were case reports. Most of the studies (n = 45, 84.9%) were level 4 on the OCEBM tool. The most common uses of NIRS were to visualize the biliary tree and to identify primary and metastatic malignant tissues. Other applications include assessment of perfusion of tissues including bowel anastomoses, and lymphatic surgery. Several advantages of the introduction of NIRS in pediatric surgery exist including having the potential to reduce operative time and intra/post-operative complications. Moreover, NIRS helps in detecting malignant tissues that can be missed by conventional imaging. However, NIRS has important limitations such as difficulty in identification of the biliary tree in obese patients or inflamed gallbladder, detection of small deeply localized malignant tissues, as well as the high cost. CONCLUSIONS NIRS is a promising modality that can be used intraoperatively to augment different pediatric surgical procedures. NIRS has important advantages and limitations compared to conventional surgery, however, more studies are required to evaluate its outcomes and cost-effectiveness. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Heba Alghoul
- Faculty of Medicine, Islamic University of Gaza, Palestine
| | - Farah Al Farajat
- Faculty of Medicine, Jordan University of Science and Technology, Jordan
| | - Osaid Alser
- Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| | - Andrea Rogers Snyr
- Beaumont Children's and Oakland University William Beaumont School of Medicine, 3535 W 13 Mile Rd, Ste 307, Royal Oak, MI 48073, United States
| | - Carroll M Harmon
- Division of Pediatric Surgery, Department of Surgery, Jacobs School of Medicine and Biomedical Sciences, University in Buffalo, NY, United States
| | - Nathan M Novotny
- Beaumont Children's and Oakland University William Beaumont School of Medicine, 3535 W 13 Mile Rd, Ste 307, Royal Oak, MI 48073, United States; Monroe Carell, Jr. Children's Hospital at Vanderbilt, Nashville, TN, United States.
| |
Collapse
|
20
|
Noureldine SI, Nazli Avci S, Isiktas G, Ergun O, Elshamy M, Berber E. Detection of near-infrared autofluorescence from adrenal neoplasms: An initial experience. J Surg Oncol 2022; 126:257-262. [PMID: 35319103 DOI: 10.1002/jso.26863] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Accepted: 03/11/2022] [Indexed: 01/18/2023]
Abstract
BACKGROUND AND OBJECTIVES Fluorescence from adrenal tumors can be detected with near-infrared imaging after injection with indocyanine green. However, it is unknown if adrenal tumors exhibit autofluorescence. The aim of this study was to determine whether adrenal tumors emit near-infrared autofluorescence (NIRAF). METHODS This was a prospective study of patients who underwent minimally invasive adrenalectomy at a tertiary center. Intraoperative images were analyzed to detect NIRAF with a 750 nm camera. Descriptive and comparative statistical analyses were performed. RESULTS Twenty-five adrenalectomies were examined. Only 11 tumors (44%), that originated from the cortex exhibited autofluorescence. A contrast distinction between the tumor and retroperitoneum was observed in 23 patients, whereas a contrast distinction between the tumor and normal adrenocortical tissue was seen in 12 patients. The overall fluorescence intensity of adrenal tumors was found to be variable and ranging between 0.3 and 5.6 times that of the background tissue. Pheochromocytoma, malignancy and adrenal cyst did not demonstrate NIRAF. CONCLUSION This is the first study to show that adrenocortical tissue can demonstrate NIRAF. The pattern of fluorescence was similar to that observed after indocyanine green injection in our historical experience. NIRAF has a potential to be used as an intraoperative optical adjunct during adrenalectomy.
Collapse
Affiliation(s)
- Salem I Noureldine
- Department of Endocrine Surgery, Endocrinology and Metabolism Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Seyma Nazli Avci
- Department of Endocrine Surgery, Endocrinology and Metabolism Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Gizem Isiktas
- Department of Endocrine Surgery, Endocrinology and Metabolism Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Onuralp Ergun
- Department of Endocrine Surgery, Endocrinology and Metabolism Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Mohammed Elshamy
- Department of Endocrine Surgery, Endocrinology and Metabolism Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Eren Berber
- Department of Endocrine Surgery, Endocrinology and Metabolism Institute, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
21
|
Guía de uso e indicaciones de la fluorescencia con verde de indocianina (ICG) en cirugía general: recomendaciones basadas en la revisión descriptiva de la literatura y el análisis de la experiencia. Cir Esp 2022. [DOI: 10.1016/j.ciresp.2021.11.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
22
|
Global trends of indocyanine green fluorescence navigation in laparoscopic cholecystectomy: bibliometrics and knowledge atlas analysis. Surg Endosc 2022; 36:6419-6431. [PMID: 35029767 DOI: 10.1007/s00464-021-08988-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 12/31/2021] [Indexed: 10/19/2022]
Abstract
BACKGROUND Indocyanine green fluorescence cholangiography is a new type of cholangiography that has emerged in recent years. It has many advantages, such as simplicity, safety, and efficiency, and is expected to become a routine procedure for intraoperative cholangiography in the future. However, there is no bibliometric analysis of horizontal generalization in this field. Therefore, this study aims to assess the current research status and developmental trends in this field from a global perspective and to help guide the focus of future research. METHODS This study was conducted by retrieving the literature related to ICG fluorescence cholangiography published in English from 2000 to 2021 from Web of Science. The Histcite. Pro tool was used to analyze the bibliometric indicators, and VOSviewer was used to visualize the research trends and hotspots in this field. RESULTS 192 related studies were finally included. For the past 20 years, the number of related publications in this field have increased yearly, with 2010 being a breakthrough point for research in this field. Research has developed rapidly since 2013 and may continue to expand in the next several years. The USA and Japan play leading roles in this field. "SURG ENDOSC", "SURG INNOV", and "J LAPAROENDOSC ADV S" are core journals that publish high-quality literature and the latest developments in this field. Some authors who have a large number of high-quality publications include Ishizawa T and Kokudo N. The current research hotspots in this field are focused on exploring the factors that affect ICG cholangiography and optimization measures. CONCLUSIONS In general, the number of documents related to ICG fluorescence cholangiography is growing rapidly, with the USA and Japan being influential countries and China being one of the major producers of these documents. The optimization of this new technology will affect key developments in future research.
Collapse
|
23
|
Serban D, Badiu D, Davitoiu D, Tanasescu C, Tudosie M, Sabau A, Dascalu A, Tudor C, Balasescu S, Socea B, Costea D, Zgura A, Costea A, Tribus L, Smarandache C. Systematic review of the role of indocyanine green near‑infrared fluorescence in safe laparoscopic cholecystectomy (Review). Exp Ther Med 2021; 23:187. [DOI: 10.3892/etm.2021.11110] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 09/30/2021] [Indexed: 11/06/2022] Open
Affiliation(s)
- Dragos Serban
- Department of General Surgery, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Dumitru Badiu
- Department of General Surgery, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Dragos Davitoiu
- Department of General Surgery, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Ciprian Tanasescu
- Third Clinical Department, Faculty of Medicine, ‘Lucian Blaga’ University of Sibiu, 550169 Sibiu, Romania
| | - Mihail Tudosie
- Discipline of Clinical Toxicology, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Alexandru Sabau
- Third Clinical Department, Faculty of Medicine, ‘Lucian Blaga’ University of Sibiu, 550169 Sibiu, Romania
| | - Ana Dascalu
- Department of General Surgery, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Corneliu Tudor
- Fourth Department of Surgery, Emergency University Hospital, 050098 Bucharest, Romania
| | - Simona Balasescu
- Fourth Department of Surgery, Emergency University Hospital, 050098 Bucharest, Romania
| | - Bogdan Socea
- Department of General Surgery, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Daniel Costea
- Department of Clinical Surgical Disciplines I, Faculty of Medicine, Ovidius University, 900527 Constanta, Romania
| | - Anca Zgura
- Department of Radiology, Oncology, and Hematology, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020011 Bucharest, Romania
| | - Andreea Costea
- Department of Nephrology and Dialysis, ‘Diaverum’ Clinic, 900612 Constanta, Romania
| | - Laura Tribus
- Department of Internal Medicine Gastroenterology, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020011 Bucharest, Romania
| | - Catalin Smarandache
- Department of General Surgery, Faculty of Medicine, ‘Carol Davila’ University of Medicine and Pharmacy, 020021 Bucharest, Romania
| |
Collapse
|
24
|
Abstract
Laparoscopic cholecystectomy is a common operation; approximately 20 million Americans have gallstones, the most common indication. Surgeons who operate on the biliary tree must be familiar with the presentations and treatment options for acute and chronic biliary pathology. We focus on the difficult "bad" gallbladder. We explore the available evidence as to what to do when a gallbladder is too inflamed, too technically challenging, or a patient is too sick to undergo standard laparoscopic cholecystectomy. We discuss whether or not open cholecystectomy is a relevant tool and what can be done to manage common bile duct stones found unexpectedly intraoperatively.
Collapse
Affiliation(s)
- Miloš Buhavac
- Texas Tech University Health Sciences Center, Department of Surgery, 3601 4th Street, Lubbock, TX 79430, USA.
| | - Ali Elsaadi
- Texas Tech University Health Sciences Center, Department of Surgery, 3601 4th Street, Lubbock, TX 79430, USA
| | - Sharmila Dissanaike
- Texas Tech University Health Sciences Center, Department of Surgery, 3601 4th Street, Lubbock, TX 79430, USA
| |
Collapse
|
25
|
Pesce A, Piccolo G, Lecchi F, Fabbri N, Diana M, Feo CV. Fluorescent cholangiography: An up-to-date overview twelve years after the first clinical application. World J Gastroenterol 2021; 27:5989-6003. [PMID: 34629815 PMCID: PMC8476339 DOI: 10.3748/wjg.v27.i36.5989] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 07/10/2021] [Accepted: 08/30/2021] [Indexed: 02/06/2023] Open
Abstract
Laparoscopic cholecystectomy (LC) is one of the most frequently performed gastrointestinal surgeries worldwide. Bile duct injury (BDI) represents the most serious complication of LC, with an incidence of 0.3%-0.7%, resulting in significant perioperative morbidity and mortality, impaired quality of life, and high rates of subsequent medico-legal litigation. In most cases, the primary cause of BDI is the misinterpretation of biliary anatomy, leading to unexpected biliary lesions. Near-infrared fluorescent cholangiography is widely spreading in clinical practice to delineate biliary anatomy during LC in elective and emergency settings. The primary aim of this article was to perform an up-to-date overview of the evolution of this method 12 years after the first clinical application in 2009 and to highlight all advantages and current limitations according to the available scientific evidence.
Collapse
Affiliation(s)
- Antonio Pesce
- Department of Surgery, Section of General Surgery, Ospedale del Delta, Azienda USL of Ferrara, University of Ferrara, Ferrara 44023, Italy
| | - Gaetano Piccolo
- Department of Health Sciences, University of Milan, Unit of Hepato-Bilio-Pancreatic and Digestive Surgery, San Paolo Hospital, Milano 20142, Italy
| | - Francesca Lecchi
- Department of Health Sciences, University of Milan, Unit of Hepato-Bilio-Pancreatic and Digestive Surgery, San Paolo Hospital, Milano 20142, Italy
| | - Nicolò Fabbri
- Department of Surgery, Section of General Surgery, Ospedale del Delta, Azienda USL of Ferrara, University of Ferrara, Ferrara 44023, Italy
| | - Michele Diana
- Department of General, Digestive and Endocrine Surgery, University Hospital of Strasbourg, IRCAD, Research Institute Against Digestive Cancer, ICUBE lab, PHOTONICS for Health, University of Strasbourg, Strasbourg Cedex F-67091, France
| | - Carlo Vittorio Feo
- Department of Surgery, Section of General Surgery, Ospedale del Delta, Azienda USL of Ferrara, University of Ferrara, Ferrara 44023, Italy
| |
Collapse
|
26
|
Lee YJ, van den Berg NS, Orosco RK, Rosenthal EL, Sorger JM. A narrative review of fluorescence imaging in robotic-assisted surgery. LAPAROSCOPIC SURGERY 2021; 5. [PMID: 34549180 PMCID: PMC8452263 DOI: 10.21037/ls-20-98] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Objective In this review, we provide examples of applications of fluorescence imaging in urologic, gynecologic, general, and endocrine surgeries. Background While robotic-assisted surgery has helped increase the availability of minimally invasive procedures across surgical specialties, there remains an opportunity to reduce adverse events associated with open, laparoscopic, and robotic-assisted methods. In 2011, fluorescence imaging was introduced as an option to the da Vinci Surgical System, and has been standard equipment since 2014. Without interfering with surgical workflow, this fluorescence technology named Firefly® allows for acquisition and display of near-infrared fluorescent signals that are co-registered with white light endoscopic images. As a result, robotic surgeons of all specialties have been able to explore the clinical utility of fluorescence guided surgery. Methods Literature searches were performed using the PubMed and MEDLINE databases using the keywords "robotic-assisted fluorescence surgery", "ICG robotic surgery", and "fluorescence guided surgery" covering the years 2011-2020. Conclusions Real-time intraoperative fluorescence guidance has shown great potential in helping guide surgeons in both simple and complex surgical interventions. Indocyanine green is one of the most widely-used imaging agents in fluorescence guided surgery, and other targeted, near-infrared imaging agents are in various stages of development. Fluorescence is becoming a reliable tool that can help surgeons in their decision-making process in some specialties, while explorations continue in others.
Collapse
Affiliation(s)
- Yu-Jin Lee
- Department of Otolaryngology-Head and Neck Surgery, Stanford University, Palo Alto, CA, USA
| | | | - Ryan K Orosco
- Moores Cancer Center, La Jolla, CA, USA.,Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, University of California, San Diego, San Diego, CA, USA
| | - Eben L Rosenthal
- Department of Otolaryngology-Head and Neck Surgery, Stanford University, Palo Alto, CA, USA
| | - Jonathan M Sorger
- Department of Research, Intuitive Surgical, Inc., Sunnyvale, CA, USA
| |
Collapse
|
27
|
Cosco ED, Lim I, Sletten EM. Photophysical Properties of Indocyanine Green in the Shortwave Infrared Region. CHEMPHOTOCHEM 2021; 5:727-734. [PMID: 34504949 PMCID: PMC8423351 DOI: 10.1002/cptc.202100045] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Indexed: 02/04/2023]
Abstract
With the growing development of new contrast agents for optical imaging using near-infrared and shortwave infrared (SWIR) wavelengths, it is essential to have consistent bench-marks for emitters in these regions. Indocyanine green (ICG), a ubiquitous and FDA-approved organic dye and optical imaging agent, is commonly employed as a standard for photophysical properties and biological performance for imaging experiments at these wavelengths. Yet, its reported photophysical properties across organic and aqueous solvents vary greatly in the literature, which hinders its ability to be used as a consistent benchmark. Herein, we measure photophysical properties in organic and aqueous solvents using InGaAs detection (~950-1,700 nm), providing particular relevance for SWIR imaging.
Collapse
Affiliation(s)
- Emily D Cosco
- Dr. E. D. Cosco, I. Lim, Prof. E. M. Sletten Department of Chemistry and Biochemistry, California NanoSystems Institute, University of California, Los Angeles, 607 Charles E. Young Dr. East, Los Angeles, CA 90095 (USA)
| | - Irene Lim
- Dr. E. D. Cosco, I. Lim, Prof. E. M. Sletten Department of Chemistry and Biochemistry, California NanoSystems Institute, University of California, Los Angeles, 607 Charles E. Young Dr. East, Los Angeles, CA 90095 (USA)
| | - Ellen M Sletten
- Dr. E. D. Cosco, I. Lim, Prof. E. M. Sletten Department of Chemistry and Biochemistry, California NanoSystems Institute, University of California, Los Angeles, 607 Charles E. Young Dr. East, Los Angeles, CA 90095 (USA)
| |
Collapse
|
28
|
Keeratibharat N. Initial experience of intraoperative fluorescent cholangiography during laparoscopic cholecystectomy: A retrospective study. Ann Med Surg (Lond) 2021; 68:102569. [PMID: 34345426 PMCID: PMC8319025 DOI: 10.1016/j.amsu.2021.102569] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/10/2021] [Accepted: 07/13/2021] [Indexed: 11/29/2022] Open
Abstract
Background Fluorescent cholangiography (FC) during laparoscopic cholecystectomy (LC) is a novel method to facilitate real-time visualization of extrahepatic biliary structures that avoiding risk of bile duct injury. Aims of this study are to investigate the feasibility and the safety of FC during LC. Method We evaluated the outcomes of FC during elective LC at our hospital from August 2017 to April 2018. Fifty-five patients who underwent FC during elective LC were enrolled in this study. Demographic and peri-operative data were recorded and analyzed. The primary endpoints were visualization rate of FC during LC. The secondary endpoint was the optimal conditions and technical details for FC included to detect any potential adverse event. Results The visualization rate after FC of the cystic duct, common hepatic duct and common bile duct were increased significantly compared to before FC. The identification rate of the cystic duct and common bile duct were not associated with BMI and history of acute cholecystitis. Conclusions FC enabled real-time visualization of extrahepatic biliary structures during LC. FC appears to be a safe and efficient approach for elective LC. Bile duct injury is one of the most complication of laparoscopic cholecystectomy. Fluorescent cholangiography is offer real-time detection of the biliary anatomy. Cholangiogram was associated with a low incidence of bile duct injury.
Collapse
Affiliation(s)
- Nattawut Keeratibharat
- School of Surgery, Institute of Medicine, Suranaree University of Technology, 111 Mahawitthayalai Ave., Suranaree, Muang, Nakhon Ratchasima, 30000, Thailand
| |
Collapse
|
29
|
Hernandez Vargas S, Lin C, Tran Cao HS, Ikoma N, AghaAmiri S, Ghosh SC, Uselmann AJ, Azhdarinia A. Receptor-Targeted Fluorescence-Guided Surgery With Low Molecular Weight Agents. Front Oncol 2021; 11:674083. [PMID: 34277418 PMCID: PMC8279813 DOI: 10.3389/fonc.2021.674083] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 05/10/2021] [Indexed: 12/16/2022] Open
Abstract
Cancer surgery remains the primary treatment option for most solid tumors and can be curative if all malignant cells are removed. Surgeons have historically relied on visual and tactile cues to maximize tumor resection, but clinical data suggest that relapse occurs partially due to incomplete cancer removal. As a result, the introduction of technologies that enhance the ability to visualize tumors in the operating room represents a pressing need. Such technologies have the potential to revolutionize the surgical standard-of-care by enabling real-time detection of surgical margins, subclinical residual disease, lymph node metastases and synchronous/metachronous tumors. Fluorescence-guided surgery (FGS) in the near-infrared (NIRF) spectrum has shown tremendous promise as an intraoperative imaging modality. An increasing number of clinical studies have demonstrated that tumor-selective FGS agents can improve the predictive value of fluorescence over non-targeted dyes. Whereas NIRF-labeled macromolecules (i.e., antibodies) spearheaded the widespread clinical translation of tumor-selective FGS drugs, peptides and small-molecules are emerging as valuable alternatives. Here, we first review the state-of-the-art of promising low molecular weight agents that are in clinical development for FGS; we then discuss the significance, application and constraints of emerging tumor-selective FGS technologies.
Collapse
Affiliation(s)
- Servando Hernandez Vargas
- The Brown Foundation Institute of Molecular Medicine, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX, United States.,Therapeutics & Pharmacology Program, The University of Texas MD Anderson UTHealth Graduate School of Biomedical Sciences, Houston, TX, United States
| | | | - Hop S Tran Cao
- Department of Surgical Oncology, Division of Surgery, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Naruhiko Ikoma
- Department of Surgical Oncology, Division of Surgery, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Solmaz AghaAmiri
- The Brown Foundation Institute of Molecular Medicine, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX, United States
| | - Sukhen C Ghosh
- The Brown Foundation Institute of Molecular Medicine, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX, United States
| | | | - Ali Azhdarinia
- The Brown Foundation Institute of Molecular Medicine, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX, United States.,Therapeutics & Pharmacology Program, The University of Texas MD Anderson UTHealth Graduate School of Biomedical Sciences, Houston, TX, United States
| |
Collapse
|
30
|
Shibata H, Aoki T, Koizumi T, Kusano T, Yamazaki T, Saito K, Hirai T, Tomioka K, Wada Y, Hakozaki T, Tashiro Y, Nogaki K, Yamada K, Matsuda K, Fujimori A, Enami Y, Murakami M. The Efficacy of Intraoperative Fluorescent Imaging Using Indocyanine Green for Cholangiography During Cholecystectomy and Hepatectomy. Clin Exp Gastroenterol 2021; 14:145-154. [PMID: 33958888 PMCID: PMC8096340 DOI: 10.2147/ceg.s275985] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 04/06/2021] [Indexed: 12/18/2022] Open
Abstract
Purpose Bile duct injury is one of the most serious complications of laparoscopic cholecystectomy. Intraoperative indocyanine green (ICG) cholangiography is a safe and useful navigation modality for confirming the biliary anatomy. ICG cholangiography is expected to be a routine method for helping avoid bile duct injuries. Patients and Methods We examined 25 patients who underwent intraoperative cholangiography using ICG fluorescence. Two methods of ICG injection are used: intrabiliary injection (percutaneous transhepatic gallbladder drainage [PTGBD], gallbladder [GB] puncture and endoscopic nasobiliary drainage [ENBD]) at a dosage of 0.025 mg during the operation or intravenous injection with 2.5 mg ICG preoperatively. Results There were 24 patients who underwent laparoscopic cholecystectomy and 1 patient who underwent hepatectomy. For laparoscopic cholecystectomy, the average operation time was 127 (50–197) minutes, and estimated blood loss was 43.2 (0–400) g. The ICG administration route was intravenous injections in 12 cases and intrabiliary injection in 12 cases (GB injection: 3 cases, PTGBD: 8 cases, ENBD:1 case). The course of the biliary tree was able to be confirmed in all cases that received direct injection into the biliary tract, whereas bile structures were recognizable in only 10 cases (83.3%) with intravenous injection. The postoperative hospital stay was 4.6 (3–9) days, and no postoperative complications (Clavien–Dindo ≧IIIa) were observed. For hepatectomy, a tumor located near the left Glissonian pedicle was resected using a fluorescence image guide. Biliary structures were fluorescent without injury after resecting the tumor. No adverse events due to ICG administration were observed, and the procedure was able to be performed safely. Conclusion ICG fluorescence imaging allows surgeons to visualize the course of the biliary tree in real time during cholecystectomy and hepatectomy. This is considered essential for hepatobiliary surgery to prevent biliary tree injury and ensure safe surgery.
Collapse
Affiliation(s)
- Hideki Shibata
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Takeshi Aoki
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Tomotake Koizumi
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Tomokazu Kusano
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Tatsuya Yamazaki
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Kazuhiko Saito
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Takahito Hirai
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Kodai Tomioka
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Yusuke Wada
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Tomoki Hakozaki
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Yoshihiko Tashiro
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Koji Nogaki
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Kosuke Yamada
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Kazuhiro Matsuda
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Akira Fujimori
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Yuta Enami
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| | - Masahiko Murakami
- Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, Tokyo, Japan
| |
Collapse
|
31
|
Laparoscopic surgery and robotic surgery for single-incision cholecystectomy: an updated systematic review. Updates Surg 2021; 73:2039-2046. [PMID: 33886106 DOI: 10.1007/s13304-021-01056-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Accepted: 04/13/2021] [Indexed: 12/15/2022]
Abstract
The role of single-incision laparoscopic cholecystectomy (SILC) and single-incision robotic cholecystectomy (SIRC) is still unclear. We update the summarization of the feasibility and safety of SILC and SIRC. A comprehensive search of SILC and SIRC of English literature published on PubMed database between January 2015 and November 2020 was performed. A total of 70 articles were included: 41 covering SILC alone, 21 showing SIRC alone, 7 reporting both, and 1 study not specified. In total, 7828 cases were recorded (SILC/SIRC/not specified, 6234/1544/50); and the gender of 7423 cases was definitively reported: the female rate was 64.0% (SILC/SIRC/not specified, 62.1%/71.5%/74.0%). The weighted mean for body mass index (BMI), operative time, blood loss and post-operative hospital stay was 25.5 kg/m2 (SILC/SIRC, 25.0/27.0 kg/m2), 73.8 min (SILC/SIRC, 68.2/88.8 min), 12.6 mL (SILC/SIRC, 12.1/14.8 mL) and 2.5 days (SILC/SIRC, 2.8/1.9 days), respectively. The pooled prevalence of an additional port, conversion to open surgery, post-operative complications, intraoperative biliary injury, and incisional hernia was 4.1% (SILC/SIRC, 4.7%/1.9%), 0.9% (SILC/SIRC, 0.7%/1.5%), 5.9% (SILC/SIRC, 6.2%/4.1%), 0.1% (SILC/SIRC, 0.2%/0.09%), and 2.1% (SILC/SIRC, 1.4%/4.8%), respectively. Compared with conventional laparoscopic cholecystectomy, SIRC has experienced more postoperative incisional hernias (risk difference = 0.05, 95% confidence interval 0.02-0.07; P < 0.0001). By far, SILC and SIRC have not been considered a standard procedure. With the innovation of medical devices and gradual accumulation of surgical experience, feasibility and safety of performing SILC and SIRC will improve.
Collapse
|
32
|
Wu D, Liu S, Zhou J, Chen R, Wang Y, Feng Z, Lin H, Qian J, Tang BZ, Cai X. Organic Dots with Large π-Conjugated Planar for Cholangiography beyond 1500 nm in Rabbits: A Non-Radioactive Strategy. ACS NANO 2021; 15:5011-5022. [PMID: 33706510 DOI: 10.1021/acsnano.0c09981] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Iatrogenic extrahepatic bile duct injury remains a dreaded complication while performing cholecystectomy. Although X-ray based cholangiography could reduce the incidence of biliary tract injuries, the deficiencies including radiation damage and expertise dependence hamper its further clinical application. The effective strategy for intraoperative cholangiography is still urgently required. Herein, a fluorescence-based imaging approach for cholangiography in the near-infrared IIb window (1500-1700 nm) using TT3-oCB, a bright aggregation-induced emission luminogen with large π-conjugated planar unit, is reported. In phantom studies, TT3-oCB nanoparticles exhibit high near-infrared IIb emission and show better image clarity at varying penetrating depths. When intrabiliary injected into the gallbladder or the common bile duct of the rabbit, TT3-oCB nanoparticles enable the real-time imaging of the biliary structure with deep penetrating capability and high signal-to-background ratio. Moreover, the tiny iatrogenic biliary injuries and the gallstones in established disease models could be precisely diagnosed by TT3-oCB nanoparticle assisted near-infrared IIb imaging. In summary, we reported a feasible application for aggregation-induced emission dots as biliary contrast agent and realized high-quality cholangiography in the near-infrared IIb window with precise diagnostic ability and nonradioactive damage, which could possibly be applied for intraoperative diagnosis.
Collapse
Affiliation(s)
- Di Wu
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, China
| | - Shunjie Liu
- Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology, Kowloon, Hong Kong, China
| | - Jing Zhou
- State Key Laboratory of Modern Optical Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou 310058, China
| | - Runze Chen
- State Key Laboratory of Modern Optical Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou 310058, China
| | - Yifan Wang
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, China
| | - Zhe Feng
- State Key Laboratory of Modern Optical Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou 310058, China
| | - Hui Lin
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, China
| | - Jun Qian
- State Key Laboratory of Modern Optical Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou 310058, China
| | - Ben Zhong Tang
- Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology, Kowloon, Hong Kong, China
- Center for Aggregation-Induced Emission, SCUT-HKUST Joint Research Institute, State Key Laboratory of Luminescent Materials and Devices, South China University of Technology, Guangzhou 510640, China
- HKUST-Shenzhen Research Institute, Nanshan, Shenzhen 518057, China
| | - Xiujun Cai
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, China
- Key Laboratory of Laparoscopic Technology of Zhejiang Province; Zhejiang Minimal Invasive Diagnosis and Treatment Technology Research Center of Severe Hepatobiliary Disease; Zhejiang Research and Development Engineering Laboratory of Minimally Invasive Technology and Equipment, Zhejiang University Cancer Center, Hangzhou 310016, China
| |
Collapse
|
33
|
Dip F, Aleman R, Frieder JS, Gomez CO, Menzo EL, Szomstein S, Rosenthal RJ. Understanding intraoperative fluorescent cholangiography: ten steps for an effective and successful procedure. Surg Endosc 2021; 35:7042-7048. [PMID: 33475844 DOI: 10.1007/s00464-020-08219-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 12/03/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND Common bile duct injuries (BDI) during laparoscopic cholecystectomy (LC) continue to be the source of morbidity and mortality. The reason for BDI is mostly related to the misidentification of the extrahepatic bile duct structures and the anatomic variability. Near-infrared fluorescent cholangiography (NIFC) has proven to enhance visualization of extrahepatic biliary structures during LCs. The purpose of this study was to describe the most important steps in the performance of NIFC. METHODS In accordance to the most current surgical practice of LC at our institution, a consensus was achieved on the most relevant steps to be followed when utilizing NIFC. Dose of indocyanine green (ICG), time of administration, and identification of critical structures were previously determined based on prospective and randomized controlled studies performed at CCF. RESULTS The ten steps identified as critical when performing NIFC during LC are preoperative administration of ICG, exposure of the hepatoduodenal ligament, initial anatomical evaluation, identification of the cystic duct and common bile duct junction, the cystic duct and its junction to the gallbladder, the CHD, the common bile duct, accessory ducts, cystic artery and, time-out and identification of Calot's triangle, and evaluation of the liver bed. CONCLUSIONS Routine use of NIFC is a useful diagnostic tool to better visualize the extrahepatic biliary structures during LC. The implementation of specific standardized steps might provide the surgeon with a better algorithm to use this technology and consequently reduce the incidence of BDI.
Collapse
Affiliation(s)
- Fernando Dip
- Department of Minimally Invasive Surgery and The Bariatric and Metabolic Institute at the Cleveland Clinic Florida, Weston, FL, USA. .,Hospital de Clinicas "Jose de San Martin", Av. Córdoba 2351, Buenos Aires, Argentina.
| | - Rene Aleman
- Department of Minimally Invasive Surgery and The Bariatric and Metabolic Institute at the Cleveland Clinic Florida, Weston, FL, USA
| | - Joel S Frieder
- Department of Minimally Invasive Surgery and The Bariatric and Metabolic Institute at the Cleveland Clinic Florida, Weston, FL, USA
| | - Camila Ortiz Gomez
- Department of Minimally Invasive Surgery and The Bariatric and Metabolic Institute at the Cleveland Clinic Florida, Weston, FL, USA
| | - Emanuele Lo Menzo
- Department of Minimally Invasive Surgery and The Bariatric and Metabolic Institute at the Cleveland Clinic Florida, Weston, FL, USA
| | - Samuel Szomstein
- Department of Minimally Invasive Surgery and The Bariatric and Metabolic Institute at the Cleveland Clinic Florida, Weston, FL, USA
| | - Raul J Rosenthal
- Department of Minimally Invasive Surgery and The Bariatric and Metabolic Institute at the Cleveland Clinic Florida, Weston, FL, USA
| |
Collapse
|
34
|
Does near-infrared fluorescent cholangiography with indocyanine green reduce bile duct injuries and conversions to open surgery during laparoscopic or robotic cholecystectomy? - A meta-analysis. Surgery 2021; 169:859-867. [PMID: 33478756 DOI: 10.1016/j.surg.2020.12.008] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 11/10/2020] [Accepted: 12/07/2020] [Indexed: 12/20/2022]
Abstract
BACKGROUND Bile duct injury and conversion-to-open-surgery rates remain unacceptably high during laparoscopic and robotic cholecystectomy. In a recently published randomized clinical trial, using near-infrared fluorescent cholangiography with indocyanine green intraoperatively markedly enhanced biliary-structure visualization. Our systematic literature review compares bile duct injury and conversion-to-open-surgery rates in patients undergoing laparoscopic or robotic cholecystectomy with versus without near-infrared fluorescent cholangiography. METHODS A thorough PubMed search was conducted to identify randomized clinical trials and nonrandomized clinical trials with ≥100 patients. Because all near-infrared fluorescent cholangiography studies were published since 2013, only studies without near-infrared fluorescent cholangiography published since 2013 were included for comparison. Incidence estimates, weighted and unweighted for study size, were adjusted for acute versus chronic cholecystitis, and for robotic versus laparoscopic cholecystectomy and are reported as events/10,000 patients. All studies were assessed for bias risk and high-risk studies excluded. RESULTS In total, 4,990 abstracts were reviewed, identifying 5 near-infrared fluorescent cholangiography studies (3 laparoscopic cholecystectomy/2 robotic cholecystectomy; n = 1,603) and 11 not near-infrared fluorescent cholangiography studies (5 laparoscopic cholecystectomy/4 robotic cholecystectomy/2 both; n = 5,070) for analysis. Overall weighted rates for bile duct injury and conversion were 6 and 16/10,000 in near-infrared fluorescent cholangiography patients versus 25 and 271/10,000 in patients without near-infrared fluorescent cholangiography. Among patients undergoing laparoscopic cholecystectomy, bile duct injuries, and conversion rates among near-infrared fluorescent cholangiography versus patients without near-infrared fluorescent cholangiography were 0 and 23/10,000 versus 32 and 255/10,000, respectively. Bile duct injury rates were low with robotic cholecystectomy with and without near-infrared fluorescent cholangiography (12 and 8/10,000), but there was a marked reduction in conversions with near-infrared fluorescent cholangiography (12 vs 322/10,000). CONCLUSION Although large comparative trials remain necessary, preliminary analysis suggests that using near-infrared fluorescent cholangiography with indocyanine green intraoperatively sizably decreases bile duct injury and conversion-to-open-surgery rates relative to cholecystectomy under white light alone.
Collapse
|
35
|
Matsumura M, Kawaguchi Y, Kobayashi Y, Kobayashi K, Ishizawa T, Akamatsu N, Kaneko J, Arita J, Kokudo N, Hasegawa K. Indocyanine green administration a day before surgery may increase bile duct detectability on fluorescence cholangiography during laparoscopic cholecystectomy. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2020; 28:202-210. [PMID: 33091224 DOI: 10.1002/jhbp.855] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 09/09/2020] [Accepted: 10/09/2020] [Indexed: 12/24/2022]
Abstract
BACKGROUND The optimal indocyanine green (ICG) administration protocol for fluorescence cholangiography during laparoscopic cholecystectomy (LC) has yet to be determined. METHODS A prospective study including 20 cases of ICG fluorescence-navigated LC was conducted. Accordingly, the first 10 patients were administered 2.5 mg of ICG on the day of surgery after intubation (surgery-day group), while the remaining 10 consecutive patients were administered 0.25 mg/kg of ICG on the evening before surgery (one-day-before group). Fluorescence intensity (FI) of each tissue and FI ratios were then compared between both groups. RESULTS The median interval between observation and ICG administration was 27 minutes and 16 hours 24 minutes in the surgery-day and one-day-before group, respectively. Although FI values for the common bile duct (CBD), liver, and hepatoduodenal ligament (HDL) were significantly lower in the one-day-before group than in the surgery-day group, CBD- , 0.6-1.2 vs 2.5, 0.9 = -4.8; P < .001), and CBD-HDL contrast (1.7, 1.4-2.4 vs 2.3, 1.5-13.3; P = .038) were significantly higher in the one-day-before group than in the surgery-day group. CONCLUSION ICG administration a day before LC may offer better CBD background contrast compared to administration just prior to surgery.
Collapse
Affiliation(s)
- Masaru Matsumura
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Yoshikuni Kawaguchi
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Yuta Kobayashi
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Kosuke Kobayashi
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Takeaki Ishizawa
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Nobuhisa Akamatsu
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Junichi Kaneko
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Junichi Arita
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Norihiro Kokudo
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, National Center for Global Health and Medicine, Tokyo, Japan
| | - Kiyoshi Hasegawa
- Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
36
|
Lwin TM, Hoffman RM, Bouvet M. Fluorescence-guided hepatobiliary surgery with long and short wavelength fluorophores. Hepatobiliary Surg Nutr 2020; 9:615-639. [PMID: 33163512 DOI: 10.21037/hbsn.2019.09.13] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Importance Fluorescence-guided surgery (FGS) is a potentially powerful tool for hepatobiliary (HPB) surgery. The high sensitivity of fluorescence navigation is especially useful in settings where tactile feedback is limited. Objective The present narrative review evaluates literature on the use of FDA-approved fluorophores such as methylene blue (MB), 5-aminolevulinic acid (5-ALA), and indocyanine green (ICG) for clinical intra-operative image-guidance during HPB surgery. Evidence Review Approaches such as dosing, timing, imaging devices and comparative endpoints are summarized. The feasibility and safety of fluorophores in visualizing the biliary tree, identify biliary leaks, outline anatomic hepatic segments, identify tumors, and evaluate perfusion and graft function in liver transplants are discussed. Findings Tumor-specific probes are a promising advancement in FGS with a greater degree of specificity. The current status of tumor-specific probes being evaluated in clinical trials are summarized. Conclusions and Relevance for Reviews Relevant discussion of promising tumor-specific probes in pre-clinical development are discussed. Fluorescence-guidance in HPB surgery is relatively new, but current literature shows that the dyes are reliably able to outline desired structures with a variety of dosing, timing, and imaging devices to provide real-time intra-operative anatomic information to surgeons. Development of tumor-specific probes will further advance the field of HPB surgery especially during oncologic resections.
Collapse
Affiliation(s)
- Thinzar M Lwin
- Department of Surgery, University of California San Diego, San Diego, CA, USA
| | - Robert M Hoffman
- Department of Surgery, University of California San Diego, San Diego, CA, USA.,AntiCancer, Inc., San Diego, CA, USA.,VA San Diego Healthcare System, San Diego, CA, USA
| | - Michael Bouvet
- Department of Surgery, University of California San Diego, San Diego, CA, USA.,VA San Diego Healthcare System, San Diego, CA, USA
| |
Collapse
|
37
|
Bustos R, Fernandes E, Mangano A, Aguiluz G, Valle V, Masrur M, Bianco F, Giulianotti PC. Robotic hepaticojejunostomy: surgical technique and risk factor analysis for anastomotic leak and stenosis. HPB (Oxford) 2020; 22:1442-1449. [PMID: 32192850 DOI: 10.1016/j.hpb.2020.02.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/12/2019] [Accepted: 02/14/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND A variety of techniques have been described for the construction of the HJ (hepaticojejunostomy). Due to its technical challenges, HJ is rarely performed in a pure laparoscopic setting. In stark contrast, the increasing availability of the robotic platform has sparked new interest in pursuing this procedure in a minimally invasive fashion. The aim of our study was to describe our surgical technique and to identify risk factors for anastomotic leak and stenosis following robotic surgery. METHODS We performed a retrospective analysis of a prospectively collected database, including all consecutive HJ carried out for different indications over a 10 year period. RESULTS One hundred fifty-two patients undergoing robotic HJ performed by the same surgeon were analyzed. Bile leak occurred in 2.6% of the patients. Stricture rate was 3.3%. The median follow up was 25.5 months. There was no mortality related to anastomotic complications. On univariate analysis, patient's age less than 65 years was the only risk factor for anastomotic stricture. On multivariate analysis, no predictor factors for leak or stenosis were identified. CONCLUSION HJs carried out in a robotic fashion allow highly satisfactory results. No independent risk factors for bile leak of stenosis were identified on multivariate analysis.
Collapse
Affiliation(s)
- Roberto Bustos
- Division of General, Minimally Invasive and Robotic Surgery, University of Illinois at Chicago, Chicago, IL, USA.
| | - Eduardo Fernandes
- Division of General, Minimally Invasive and Robotic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Alberto Mangano
- Division of General, Minimally Invasive and Robotic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Gabriela Aguiluz
- Division of General, Minimally Invasive and Robotic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Valentina Valle
- Division of General, Minimally Invasive and Robotic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Mario Masrur
- Division of General, Minimally Invasive and Robotic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Francesco Bianco
- Division of General, Minimally Invasive and Robotic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Pier C Giulianotti
- Division of General, Minimally Invasive and Robotic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
38
|
Wu Y, Zhang F. Exploiting molecular probes to perform near‐infrared fluorescence‐guided surgery. VIEW 2020. [DOI: 10.1002/viw.20200068] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Affiliation(s)
- Yifan Wu
- Department of Chemistry State Key Laboratory of Molecular Engineering of Polymers Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials and iChem Fudan University Shanghai China
| | - Fan Zhang
- Department of Chemistry State Key Laboratory of Molecular Engineering of Polymers Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials and iChem Fudan University Shanghai China
| |
Collapse
|
39
|
Sevieri M, Silva F, Bonizzi A, Sitia L, Truffi M, Mazzucchelli S, Corsi F. Indocyanine Green Nanoparticles: Are They Compelling for Cancer Treatment? Front Chem 2020; 8:535. [PMID: 32766203 PMCID: PMC7378786 DOI: 10.3389/fchem.2020.00535] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 05/25/2020] [Indexed: 12/14/2022] Open
Abstract
Indocyanine green (ICG) is a Food and Drug Administration–approved near-infrared fluorescent dye, employed as an imaging agent for different clinical applications due to its attractive physicochemical properties, high sensitivity, and safety. However, free ICG suffers from some drawbacks, such as relatively short circulation half-life, concentration-dependent aggregation, and rapid clearance from the body, which would confine its feasible application in oncology. Here, we aim to discuss encapsulation of ICG within a nanoparticle formulation as a strategy to overcome some of its current limitations and to enlarge its possible applications in cancer diagnosis and treatment. Our purpose is to provide a short but exhaustive overview of clinical outcomes that these nanocomposites would provide, discussing opportunities, limitations, and possible impacts with regard to the main clinical needs in oncology.
Collapse
Affiliation(s)
- Marta Sevieri
- Laboratorio di Nanomedicina, Dipartimento di Scienze Biomediche e Cliniche "L. Sacco", Università di Milano, Milan, Italy
| | - Filippo Silva
- Laboratorio di Nanomedicina, Dipartimento di Scienze Biomediche e Cliniche "L. Sacco", Università di Milano, Milan, Italy
| | - Arianna Bonizzi
- Laboratorio di Nanomedicina, Dipartimento di Scienze Biomediche e Cliniche "L. Sacco", Università di Milano, Milan, Italy
| | - Leopoldo Sitia
- Laboratorio di Nanomedicina, Dipartimento di Scienze Biomediche e Cliniche "L. Sacco", Università di Milano, Milan, Italy
| | - Marta Truffi
- Laboratorio di Nanomedicina e Imaging Molecolare, Istituti Clinici Scientifici Spa-Società Benefit IRCCS, Pavia, Italy
| | - Serena Mazzucchelli
- Laboratorio di Nanomedicina, Dipartimento di Scienze Biomediche e Cliniche "L. Sacco", Università di Milano, Milan, Italy
| | - Fabio Corsi
- Laboratorio di Nanomedicina, Dipartimento di Scienze Biomediche e Cliniche "L. Sacco", Università di Milano, Milan, Italy.,Laboratorio di Nanomedicina e Imaging Molecolare, Istituti Clinici Scientifici Spa-Società Benefit IRCCS, Pavia, Italy
| |
Collapse
|
40
|
Robotic liver surgery—advantages and limitations. Eur Surg 2020. [DOI: 10.1007/s10353-020-00650-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
|
41
|
Rajanbabu A, Patel VJ. Ureteric mapping with Indocyanine green: A new tool to prevent ureteral injury in complex gynecological surgery. JOURNAL OF ENDOMETRIOSIS AND PELVIC PAIN DISORDERS 2020. [DOI: 10.1177/2284026520934272] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Introduction: The aim of this video is to show that ureteric injection of Indocyanine green dye in difficult gynecological operations is a useful tool to identify and safeguard ureters. Case description: A 56-year-old lady with a large 10.5 × 14.5 × 13 cm3 multiloculated endometriotic cyst in the right adnexa was scheduled for robotic-assisted hysterectomy with bilateral salphingooophorectomy. She had undergone a laparotomy and three laparoscopic surgeries for endometriosis and fibroid uterus. Before starting surgery, cystoscopy was performed and with 6 Fr ureteral catheter inserted into ureteral orifice, 5 mL of 0.5% Indocyanine green dye (Aurolab, Madurai, India) was injected into both ureters. Intraoperatively bilateral adnexal cysts were seen densely adherent to omentum, sigmoid colon, sigmoid mesocolon, bladder, and lateral pelvic wall. Bladder and rectosigmoid were pulled up both anteriorly and posteriorly, respectively, and densely adherent to uterus and to adnexal cysts. During surgery, the course of ureter was identified by the green fluorescence emitted by the Indocyanine green dye under near-infrared light on da Vinci Xi camera. During this difficult surgery, the real-time visualization of ureteric course helped to identify and safeguard ureter during adhesiolysis and surgery could be completed without any injury to ureter. Patient did not experience any side effects due to the ureteric Indocyanine green injection. Conclusion: Endometriosis can distort the pelvic anatomy making surgery very challenging. Identifying the course of ureter during surgery can help in avoiding injuries and reduce surgical morbidity.
Collapse
Affiliation(s)
- Anupama Rajanbabu
- Gynecologic Oncology Division, Amrita Institute of Medical Sciences and Research Centre, Cochin, India
| | - Viral J Patel
- Gynecologic Oncology Division, Amrita Institute of Medical Sciences and Research Centre, Cochin, India
| |
Collapse
|
42
|
Wu D, Xue D, Zhou J, Wang Y, Feng Z, Xu J, Lin H, Qian J, Cai X. Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis. Theranostics 2020; 10:3636-3651. [PMID: 32206113 PMCID: PMC7069080 DOI: 10.7150/thno.41127] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2019] [Accepted: 01/31/2020] [Indexed: 12/16/2022] Open
Abstract
Rationale: Biliary tract injury remains the most dreaded complication during laparoscopic cholecystectomy. New intraoperative guidance technologies, including near-infrared (NIR) fluorescence cholangiography with indocyanine green (ICG), are under comprehensive evaluation. Previous studies had shown the limitations of traditional NIR light (NIR-I, 700-900 nm) in visualizing the biliary tract structures in specific clinical situations. The aim of this study was to evaluate the feasibility of performing the extrahepatic cholangiography in the second NIR window (NIR-II, 900-1700 nm) and compare it to the conventional NIR-I imaging. Methods: The absorption and emission spectra, as well as fluorescence intensity and photostability of ICG-bile solution in the NIR-II window were recorded and measured. In vitro intralipid® phantom imaging was performed to evaluate tissue penetrating depth in NIR-I and NIR-II window. Different clinical scenarios were modeled by broadening the penetration distance or generating bile duct injuries, and bile duct visualization and lesion site diagnosis in the NIR-II window were evaluated and compared with NIR-I imaging. Results: The fluorescence spectrum of ICG-bile solution extends well into the NIR-II region, exhibiting intense emission value and excellent photostability sufficient for NIR-II biliary tract imaging. Extrahepatic cholangiography using ICG in the NIR-II window obviously reduced background signal and enhanced penetration depth, providing more structural information and improved visualization of the bile duct or lesion location in simulated clinical scenarios, outperforming the NIR-I window imaging. Conclusions: The conventional clinically approved agent ICG is an excellent fluorophore for NIR-II bile duct imaging. Fluorescence cholangiography with ICG in the NIR-II window could provide adequate visualization of the biliary tract structures with increased resolution and penetration depth and might be a valid option to increase the safety of cholecystectomy in difficult cases.
Collapse
Affiliation(s)
- Di Wu
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
| | - Dingwei Xue
- Department of Urology, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
| | - Jing Zhou
- State Key Laboratory of Modern Optical Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, China
| | - Yifan Wang
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
| | - Zhe Feng
- State Key Laboratory of Modern Optical Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, China
| | - Junjie Xu
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
| | - Hui Lin
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
| | - Jun Qian
- State Key Laboratory of Modern Optical Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, China
| | - Xiujun Cai
- Department of General Surgery, Sir Run-Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
- Zhejiang Provincial Key Laboratory of Laparoscopic Technology, Hangzhou, 310016, China
| |
Collapse
|
43
|
Abstract
Robotic surgery has rapidly evolved. It is particularly attractive as an alternative minimally invasive approach in liver surgery because of improvements in visualization and articulated instruments. Limitations include increased operative times and lack of tactile feedback, but these have not been shown in studies. Considerations unique to robotic surgery, including safety protocols, must be put in place and be reviewed at the beginning of every procedure to ensure safety in the event of an emergent conversion. Despite the lack of early adoption by many hepatobiliary surgeons, robotic liver surgery continues to evolve and find its place within hepatobiliary surgery.
Collapse
Affiliation(s)
- Kelly J Lafaro
- Department of Surgery, Johns Hopkins University School of Medicine, Blalock Building, 600 N. Wolfe St, Baltimore, MD 21205, USA
| | - Camille Stewart
- Department of Surgery, City of Hope National Medical Center, 1500 East Duarte Road, Duarte, CA 91010, USA
| | - Abigail Fong
- Department of Surgery, City of Hope National Medical Center, 1500 East Duarte Road, Duarte, CA 91010, USA; Department of Surgery, Cedars Sinai Medical Center, 8700 Beverly Blvd, Los Angeles, CA 90048, USA
| | - Yuman Fong
- Department of Surgery, City of Hope National Medical Center, 1500 East Duarte Road, Duarte, CA 91010, USA.
| |
Collapse
|
44
|
Troisi RI, Pegoraro F, Giglio MC, Rompianesi G, Berardi G, Tomassini F, De Simone G, Aprea G, Montalti R, De Palma GD. Robotic approach to the liver: Open surgery in a closed abdomen or laparoscopic surgery with technical constraints? Surg Oncol 2019; 33:239-248. [PMID: 31759794 DOI: 10.1016/j.suronc.2019.10.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2019] [Accepted: 10/24/2019] [Indexed: 02/07/2023]
Abstract
The application of the minimally invasive approach has shown to be safe and effective for liver surgery and is in constant growth. The indications for laparoscopic surgery are steadily increasing across the field. In the early 2000s, robotic surgery led to some additional improvements, such as tremor filtration, instrument stability, 3D view and more comfort for the surgeon. These techniques bring in some advantages compared to the traditional OLR: less blood loss, shorter admissions, fewer adhesions, and a faster postoperative recovery and better outcomes in case of further hepatectomy for tumor recurrence has been shown. Concerning which is the best minimally invasive approach between laparoscopic and robotic surgery, the evidence is still conflicting. The latter shows good potential, since the endo-wristed instruments work similarly to the surgeon's hands, even with an intact abdominal wall. However, the technique is still under development, burdened by important costs, and limited by the lack of some instruments available for the laparoscopic approach. The paucity of universally accepted and proven data, especially concerning long-term outcomes, hampers drawing univocal acceptance at present. Furthermore, the number of variables related both to the patient and the disease further complicates the decision leading to a treatment tailored to each patient with strict selection. This review aims to explore the main differences between laparoscopic and robotic surgery, focusing on indications, operative technique and current debated clinical issues in recent literature.
Collapse
Affiliation(s)
- Roberto Ivan Troisi
- Department of Clinical Medicine and Surgery, Interuniversity Center for Technological Innovation Interdepartmental Center for Robotic Surgery, Federico II University Naples, Italy; Department of Human Structure and Repair, Ghent University Faculty of Medicine, Belgium.
| | - Francesca Pegoraro
- Department of Clinical Medicine and Surgery, Interuniversity Center for Technological Innovation Interdepartmental Center for Robotic Surgery, Federico II University Naples, Italy
| | - Mariano Cesare Giglio
- Department of Clinical Medicine and Surgery, Interuniversity Center for Technological Innovation Interdepartmental Center for Robotic Surgery, Federico II University Naples, Italy
| | | | - Giammauro Berardi
- Department of Human Structure and Repair, Ghent University Faculty of Medicine, Belgium
| | - Federico Tomassini
- Department of Human Structure and Repair, Ghent University Faculty of Medicine, Belgium
| | - Giuseppe De Simone
- Department of Clinical Medicine and Surgery, Interuniversity Center for Technological Innovation Interdepartmental Center for Robotic Surgery, Federico II University Naples, Italy
| | - Giovanni Aprea
- Department of Clinical Medicine and Surgery, Interuniversity Center for Technological Innovation Interdepartmental Center for Robotic Surgery, Federico II University Naples, Italy
| | - Roberto Montalti
- Department of Public Health, Federico II University Naples, Italy
| | - Giovanni Domenico De Palma
- Department of Clinical Medicine and Surgery, Interuniversity Center for Technological Innovation Interdepartmental Center for Robotic Surgery, Federico II University Naples, Italy
| |
Collapse
|
45
|
Clinical application and technical standardization of indocyanine green (ICG) fluorescence imaging in pediatric minimally invasive surgery. Pediatr Surg Int 2019; 35:1043-1050. [PMID: 31273452 DOI: 10.1007/s00383-019-04519-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/28/2019] [Indexed: 12/27/2022]
Abstract
PURPOSE We reported our preliminary experience using ICG fluorescence in pediatric minimally invasive surgery (MIS) with the aim to standardize indications, dose, timing, and modality of administration of ICG according to different organs. METHODS ICG technology was adopted in 46 MIS procedures performed in our unit over the last 18 months: 30 left varicocele repairs; 5 cholecystectomies in obese adolescents; 3 tumor excisions; 3 nephrectomies; 2 partial nephrectomies; 3 lymphoma excisions. ICG solution was injected intravenously in all cases except for varicocelectomy in which it was injected into the testis. The ICG injection was performed intra-operatively in all cases except for cholecystectomy in which it was injected 18 h prior to the procedure. RESULTS All procedures were completed laparoscopically without conversions or intra-operative complications. No adverse or allergic reactions to ICG were reported. CONCLUSION Our preliminary experience showed that ICG fluorescence is a safe, useful, and versatile technique to adopt in pediatric MIS to achieve a better identification of anatomy and an easier surgical dissection or resection in challenging cases. Currently, the main indications are varicocelectomy, difficult cholecystectomy, tumor excision, nephrectomy, and partial nephrectomy. The main limitation is the needing of a special equipment to use ICG technology.
Collapse
|
46
|
Jang EJ, Roh YH, Kang CM, Kim DK, Park KJ. Single-Port Laparoscopic and Robotic Cholecystectomy in Obesity (>25 kg/m 2). JSLS 2019; 23:JSLS.2019.00005. [PMID: 31148915 PMCID: PMC6535466 DOI: 10.4293/jsls.2019.00005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
Background and Objectives Single-port cholecystectomy has emerged as an alternative technique to reduce the number of ports and improve cosmesis. Few previous studies have assessed obesity-related surgical outcomes following single-port cholecystectomy. In this study, technical feasibility and surgical outcomes of single-port laparoscopic cholecystectomy (SPLC) and robotic single-site cholecystectomy (RSSC) in obese patients were investigated. Methods We conducted a two-center collaborative study and retrospectively reviewed initial experiences of RSSC and SPLC in patients whose body mass index was over 25 kg/m2. Medical records of patients were reviewed. Clinical characteristics and short-term oncologic outcomes were considered and compared between SPLC and RSSC groups. Results RSSC and SPLC were performed in 39 and 78 patients, respectively. In comparative analysis, the total operative time was longer in the RSSC group (109.92 minutes vs. 60.99 minutes; P < .001).However, requiring additional port for completion of surgical procedure was less frequent in the RSSC group (0% vs. 12.8%; P = .029). Immediate postoperative pain score was not significantly different between the two groups (4.95 vs. 5.00; P = .882). However, pain score was significantly lower in the RSSC group at the time of discharge (1.79 vs. 2.38; P = .010). Conversion to conventional multiport cholecystectomy, intraoperative bile spillage, or complication rate was not significantly different between the two groups (P > .05). Conclusions SPLC and RSSC could be safely performed in selected patients with high body mass index, showing no significant clinical differences.
Collapse
Affiliation(s)
- Eun Jeong Jang
- Department of Surgery, Dong-A University College of Medicine, Busan, Korea
| | - Young Hoon Roh
- Department of Surgery, Dong-A University College of Medicine, Busan, Korea
| | - Chang Moo Kang
- Department of Surgery, Yonsei University College of Medicine, Seoul, Korea
| | - Dong Kyun Kim
- Department of Internal Medicine, Dona-A University Medical center, Busan, Korea
| | - Ki Jae Park
- Department of Surgery, Dong-A University College of Medicine, Busan, Korea
| |
Collapse
|
47
|
Quaresima S, Balla A, Palmieri L, Seitaj A, Fingerhut A, Ursi P, Paganini AM. Routine near infra-red indocyanine green fluorescent cholangiography versus intraoperative cholangiography during laparoscopic cholecystectomy: a case-matched comparison. Surg Endosc 2019; 34:1959-1967. [PMID: 31309307 DOI: 10.1007/s00464-019-06970-0] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Accepted: 07/01/2019] [Indexed: 12/18/2022]
Abstract
BACKGROUND The aim is to evaluate safety and efficacy of near infra-red (NIR) indocyanine green (ICG) fluorescence structural imaging during laparoscopic cholecystectomy (LC) (Group A) and to compare perioperative data, including operative time, with a series of patients who underwent LC with routine traditional intraoperative cholangiography (IOC) (Group B). METHODS Forty-four patients with acute or chronic cholecystitis underwent NIR-ICG fluorescent cholangiography during LC. ICG was administered intravenously at different time intervals or by direct gallbladder injection during surgery. Fluorescence intensity and anatomy identification were scored according to a visual analogue scale between 1 (least accurate) and 5 (most accurate). Group B patients (n = 44) were chosen from a prospectively maintained database of patients who underwent LC with routine IOC, matched for age, sex, body mass index, and diagnosis with group A patients. RESULTS No adverse reactions were recorded. In group A, mean time between intravenous administration of ICG and surgery was 10.7 ± 8.2 (range 2-52) h. Administered doses ranged from 3.5 to 13.5 mg. Fluorescence was present in all cases, scoring ≥ 3 in 41 patients. Mean operative time was 86.9 ± 36.9 (30-180) min in group A and 117.9 ± 43.4 (40-220) min in group B (p = 0.0006). No conversion to open surgery nor bile duct injuries were observed in either group. CONCLUSIONS LC with NIR-ICG fluorescent cholangiography is safe and effective for early recognition of anatomical landmarks, reducing operative time as compared to LC with IOC, even when residents were the main operator. NIR-ICG fluorescent cholangiography was effective in patients with acute cholecystitis and in the obese. Data collection into large registries on the results of NIR-ICG fluorescent cholangiography during LC should be encouraged to establish whether this technique might set a new safety standard for LC.
Collapse
Affiliation(s)
- Silvia Quaresima
- Department of General Surgery and Surgical Specialties "Paride Stefanini", Sapienza University of Rome, Azienda Policlinico Umberto I, Viale del Policlinico 155, 00161, Rome, Italy.
| | - Andrea Balla
- Department of General Surgery and Surgical Specialties "Paride Stefanini", Sapienza University of Rome, Azienda Policlinico Umberto I, Viale del Policlinico 155, 00161, Rome, Italy
| | - Livia Palmieri
- Department of General Surgery and Surgical Specialties "Paride Stefanini", Sapienza University of Rome, Azienda Policlinico Umberto I, Viale del Policlinico 155, 00161, Rome, Italy
| | - Ardit Seitaj
- Department of General Surgery and Surgical Specialties "Paride Stefanini", Sapienza University of Rome, Azienda Policlinico Umberto I, Viale del Policlinico 155, 00161, Rome, Italy
| | - Abe Fingerhut
- Section for Surgical Research, Department of Surgery, Medical University of Graz, 8036, Graz, Austria
- Department of Gastrointestinal Surgery, Ruijin Hospital and Jiao Tong University School of Medicine, Shanghai, 20025, China
| | - Pietro Ursi
- Department of General Surgery and Surgical Specialties "Paride Stefanini", Sapienza University of Rome, Azienda Policlinico Umberto I, Viale del Policlinico 155, 00161, Rome, Italy
| | - Alessandro M Paganini
- Department of General Surgery and Surgical Specialties "Paride Stefanini", Sapienza University of Rome, Azienda Policlinico Umberto I, Viale del Policlinico 155, 00161, Rome, Italy
| |
Collapse
|
48
|
1st report of unexpected true left-sided gallbladder treated with robotic approach. Int J Surg Case Rep 2019; 58:100-103. [PMID: 31035225 PMCID: PMC6488559 DOI: 10.1016/j.ijscr.2019.04.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 03/27/2019] [Accepted: 04/08/2019] [Indexed: 11/20/2022] Open
Abstract
For left-sided gallbladder, no change of port setting is needed using the robot. ICG helps to recognize associated vascular and biliary anomalies. Anatomical variations assessment is crucial to avoid biliary or vascular injuries.
Introduction True left-sided gallbladder (T-LSG) occur when the gallbladder is positioned to the left of the ligamentum teres and falciform ligament and under the surface of the left liver lobe. Presentation of case Patient is 29-year-old caucasian male, presenting with 9-month history of epigastric right upper quadrant (RUQ) colic pain. RUQ Ultrasound reported cholelithiasis, gallbladder wall thickening, and no intrahepatic biliary dilation. Discussion Robotic cholecystectomy was the chosen approach. When visceral surface of the liver was exposed, anomalous location of the gallbladder was noted, left to the round ligament. A cystic duct with a “hairpin” configuration and a very cephalad cystic artery were identified. Cholecystectomy was performed safely and uneventfully. Conclusion No change of port setting was required with the robotic approach. The ICG-aided cholangiography improved surgeon’s ability to recognize the concomitant vascular and biliary anomalies. However, no definitive conclusion can be drown until further experience and volume are achieved.
Collapse
|
49
|
The Feasibility and Safety of Preoperative Fluorescence Marking with Indocyanine Green (ICG) in Laparoscopic Gastrectomy for Gastric Cancer. J Gastrointest Surg 2019; 23:468-476. [PMID: 30084063 DOI: 10.1007/s11605-018-3900-0] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2018] [Accepted: 07/23/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Securing the surgical margin is the most essential and important task in curative surgery. However, it is difficult to accurately identify the tumor location during laparoscopic surgery for gastric cancer, and existing methods, such as preoperative endoscopic marking with tattooing and clipping, have multiple disadvantages. AIMS We investigated the feasibility and safety of indocyanine green (ICG) fluorescence marking for determining the tumor location during laparoscopic gastrectomy. METHODS We retrospectively analyzed preoperative and perioperative data from consecutive patients with gastric cancer undergoing planned laparoscopic distal gastrectomy. Data was maintained in a prospectively compiled surgical database, and patients were categorized into ICG (n = 84) or non-ICG (n = 174) groups based on whether they underwent preoperative endoscopic mucosal ICG injection. One-to-one propensity score matching (PSM) was performed to compare outcomes between the two groups. RESULTS We included 84 patient pairs after PSM, and there were no significant differences in preoperative patient characteristics. The ICG group had shorter procedure time (p < 0.001), lower estimated blood loss (p = 0.005), and significantly shorter postoperative hospital stay (p < 0.001). Positive resection margins were confirmed in five cases (6.0%) in the non-ICG group, whereas there were none in the ICG group (p = 0.008). Real-time confirmation was possible during laparoscopy, and the injected ICG did not affect the surgical procedure or result in adverse events. CONCLUSION ICG fluorescence imaging is feasible and safe and can potentially be used as a tumor-marking agent for determining the surgical resection line.
Collapse
|
50
|
Safe laparoscopic cholecystectomy: A systematic review of bile duct injury prevention. Int J Surg 2018; 60:164-172. [PMID: 30439536 DOI: 10.1016/j.ijsu.2018.11.006] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Revised: 10/14/2018] [Accepted: 11/04/2018] [Indexed: 12/13/2022]
Abstract
BACKGROUND Since the introduction of laparoscopic cholecystectomy (LC), a substantial increase in bile duct injury (BDI) incidence was noted. Multiple methods to prevent this complication have been developed and investigated. The most suitable method however is subject to debate. In this systematic review, the different modalities to aid in the safe performance of LC and prevent BDI are delineated. MATERIALS AND METHODS A systematic search for articles describing methods for the prevention of BDI in LC was conducted using EMBASE, Medline, Web of science, Cochrane CENTRAL and Google scholar databases from inception to 11 June 2018. RESULTS 90 studies were included in this systematic review. Overall, BDI preventive techniques can be categorized as dedicated surgical approaches (Critical View of Safety (CVS), fundus first, partial laparoscopic cholecystectomy), supporting imaging techniques (intraoperative radiologic cholangiography, intraoperative ultrasonography, fluorescence imaging) and others. Dedicated surgical approaches demonstrate promising results, yet limited research is provided. Intraoperative radiologic cholangiography and ultrasonography demonstrate beneficial effects in BDI prevention, however the available evidence is low. Fluorescence imaging is in its infancy, yet this technique is demonstrated to be feasible and larger trials are in preparation. CONCLUSION Given the low sample sizes and suboptimal study designs of the studies available, it is not possible to recommend a preferred method to prevent BDI. Surgeons should primarily focus on proper dissection techniques, of which CVS is most suitable. Additionally, recognition of hazardous circumstances and knowledge of alternative techniques is critical to complete surgery with minimal risk of injury to the patient.
Collapse
|