1
|
Rodríguez-Fernández C, Ruiz-Garcia P, Garcia-Sanchez MJ, Manrique-Zegarra M, Toledano-Illán C, Escartin J, Vences MA, Rubio LA, Luttich A, Pumar JM. Technical success, procedural safety, and efficacy of the Silk Vista Baby in the treatment of cerebral aneurysms over a mid-to-long-term follow-up. Front Neurol 2024; 15:1369443. [PMID: 38638309 PMCID: PMC11025534 DOI: 10.3389/fneur.2024.1369443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 03/14/2024] [Indexed: 04/20/2024] Open
Abstract
Background Long-term follow-up of cerebral aneurysms treated with the Silk Vista Baby (SVB) flow diverter is lacking. This study aimed to assess the technical success, procedural safety, and efficacy of the SVB (Balt, Montmorency, France) for the treatment of intracranial aneurysms in small cerebral vessels over a mid-to long-term follow-up. Methods We retrospectively analyzed a prospectively maintained database of patients treated with the SVB between September 2018 and June 2021. Data regarding patient demographics, aneurysm characteristics, and technical procedures were also collected. Angiographic and clinical findings were recorded during the procedure and over a period of at least 12 months. Results Angiographic and clinical follow-up data were available for 50 patients/50 aneurysms. The procedural complication rate was 8%. At 12 months, the final results showed a technical success rate of 100%, the re rupture rate was 0%, neuromorbidity and mortality rates of 4 and 0%, respectively, and an almost complete occlusion rate of 94%. Conclusion Treatment of complex intracranial aneurysms with the SVB was safe and effective. Long-term results showed high rates of adequate and stable occlusions.
Collapse
Affiliation(s)
| | - Pedro Ruiz-Garcia
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | | | - Martiel Manrique-Zegarra
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | - Carlos Toledano-Illán
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | - Jorge Escartin
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | - Miguel Angel Vences
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
- School of Medicine, Universidad César Vallejo, Piura, Peru
| | - Luis Angel Rubio
- Interventional Neuroradiology Department, Hospital Universitario Fundación Jiménez Diaz, Madrid, Spain
| | - Alex Luttich
- Interventional Neuroradiology Department, Hospital Universitario Donostia, San Sebastian, Spain
| | - José Manuel Pumar
- Chair of Interventional Neuroradiology, University of Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|
2
|
Hanel RA, Cortez GM, Benalia VHC, Sheffels E, Sutphin DJ, Pederson JM, Pereira VM. Patient outcomes after treatment of brain aneurysm in small diameter vessels with the silk vista baby flow diverter: A systematic review. Interv Neuroradiol 2024; 30:5-13. [PMID: 35392703 PMCID: PMC10956459 DOI: 10.1177/15910199221091645] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 03/16/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND The Silk Vista Baby (SVB, BALT) is a first-in-class flow-diverter device delivered using a 0.017" microcatheter, designed for the treatment of intracranial aneurysms, including those in small diameter vessels. This study reports a systematic literature review (SLR) to evaluate the safety and efficacy of using SVB to treat intracranial aneurysms in vessels less than 3.5 mm in diameter. METHODS We performed a PRISMA-compliant SLR to evaluate the outcomes of SVB in the treatment of aneurysms in small intracranial vessels. Primary outcomes were occlusion status and major stroke, and secondary outcomes included all-cause mortality, procedure-related neurologic death, and post-operative aneurysm rupture. Data were expressed as descriptive statistics only. RESULTS A total of four studies, including 163 patients with 173 intracranial aneurysms, were included. The most common aneurysm locations were the anterior cerebral artery (24.9% [43/173]), the middle cerebral artery (24.3% [42/173]), and the anterior communicating artery (23.1% [40/173]). Parent artery diameter ranged from 0.9 mm to 3.6 mm, and 29% were acutely or previously ruptured aneurysms. Overall, complete or near-complete occlusion was 72.1% on early-term follow-up. Mortality rate among the studies was 2.5%, with 3 instances adjudicated as neurologic deaths (1.8%). Major stroke was noted in 1.2% of cases, and branch occlusion or stent thrombus formation in 5.5%. CONCLUSION Our review suggests that SVB is a safe and effective treatment for intracranial aneurysms in small vessels. Further prospective and comparative studies with patient outcome data specific to aneurysm location are needed to confirm the safety and efficacy of SVB.
Collapse
Affiliation(s)
- Ricardo A Hanel
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, FL, USA
| | - Gustavo M Cortez
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, FL, USA
- Research Department, Jacksonville University, Jacksonville, FL, USA
| | - Victor H C Benalia
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, FL, USA
- Research Department, Jacksonville University, Jacksonville, FL, USA
| | | | | | | | - Vitor M Pereira
- Departments of Surgery and Medical Imaging, Division of Neurosurgery, St Michaels Hospital, University of Toronto, Ontario, Canada
| |
Collapse
|
3
|
Endovascular treatment of challenging aneurysms with FRED Jr flow diverter stents: a single-center experience. Jpn J Radiol 2023; 41:322-334. [PMID: 36315360 PMCID: PMC9619020 DOI: 10.1007/s11604-022-01354-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Accepted: 10/20/2022] [Indexed: 01/24/2023]
Abstract
PURPOSE To analyze clinical safety and efficacy of flow re-direction endoluminal device (FRED) Jr flow diverter for treatment of unruptured, ruptured, or recanalyzed aneurysms. MATERIALS AND METHODS Between October 2019 and February 2022, 25 patients with 31 aneurysms treated with FRED Jr were included in the study. Clinical and radiological records, procedural details, and follow-up outcomes were retrospectively evaluated. Eighteen (72%) patients were female. Median age was 48.8 (age range 9-85). Mean follow-up was 21 months (6-28 months). Location of the aneurysms were as follows; 13 in middle cerebral artery (MCA), 7 in anterior cerebral artery (ACA), 4 in posterior cerebral artery (PCA), 3 in true posterior communicating artery (PCom), 2 in anterior communicating artery (ACom), 1 in superior cerebellar artery (SCA), 1 in true ophthalmic artery. Five patients (20%) presented with acute subarachnoid hemorrhage (aSAH). RESULTS In all procedures, FRED Jr was successfully deployed. Three true Pcom aneurysms and a true ophthalmic aneurysm were treated with FRED Jr. Three patients with two adjacent aneurysms were treated with a single FRED Jr. In two (8%) patients in-stent thrombosis occurred intraoperatively, they were treated with iv tirofiban and thrombectomy without any sequelae. Post-discharge 2 weeks later, intraparenchymal hemorrhage occurred in a patient. He was treated with surgical drainage, the clinical course was modified Rankin score (mRS) 2. Digital subtraction angiography (DSA) was performed on 16 (64%) patients with 21 (67%) aneurysms. Near complete-complete occlusion (O'Kelly-Morata grading scale (OKM C-D) was documented in 15/16 (93.7%) patients, 20/21 (95.2%) aneurysms. In nine (36%) patients, no residual filling was observed in the magnetic resonance angiography (MRA). Good clinical outcome (mRS 0-1) was achieved in 24/25 (96%) of patients. CONCLUSION Endovascular treatment of small cerebral aneurysms with FRED Jr is safe and effective even in complex and challenging morphologies allowing high rates of aneurysm occlusion with low periprocedural complications. Our cohort, consisting of a rate 20% acute ruptured aneurysms, is the major additive data to the published literature.
Collapse
|
4
|
Benalia VHC, Cortez GM, Brasiliense LBC, Starke RM, Killer-Oberpfalzer M, Lopes DK, Kan PT, Nogueira RG, Johnson JN, Pereira VM, Kilburg C, Khalili S, Hanel RA. Silk Vista Baby for the Treatment of Complex Posterior Inferior Cerebellar Artery Aneurysms. Neurosurgery 2022; 91:547-554. [PMID: 35830269 DOI: 10.1227/neu.0000000000002072] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 05/09/2022] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Treatment of small-caliber vessel lesions using flow diverters remains challenging because of vasculature's narrow luminal diameter and tortuosity. This in turn makes navigation and delivery of conventional devices with standard microcatheters more difficult. The Silk Vista Baby (SVB, Balt) flow diversion device was designed for ease of use in vessels with a smaller diameter, distal lesions, and 0.017 ″ microcatheter delivery systems. OBJECTIVE To report the outcomes of the SVB device on the treatment of posterior inferior cerebellar artery (PICA) aneurysms. METHODS Databases from different centers were retrospectively reviewed for PICA aneurysms treated with SVB. Demographic information, clinical presentation, radiographic characteristics, procedural complications, and immediate postprocedure outcomes were obtained. RESULTS Fourteen patients harboring 15 true PICA aneurysms were treated between January 2019 and June 2021. Nine were female (n = 9/14; 64.2%), and the mean age was 51 ± 14.9 years. Most patients had previously ruptured aneurysms, treated by another endovascular technique. Six aneurysms were located distally (n = 6/15; 40%). The mean neck size was 3 mm (SD 1.35, range 2.5-5 mm), whereas the mean PICA diameter was 1.6 mm (SD 0.26, range 1.5-1.7 mm). The mean length of follow-up was 6 months (SD 8.28, range 4.5-16 months). Treatment-related adverse events included 1 case of transient hypoesthesia. Two additional events were reported, but adjudicated as unrelated to the procedure. Complete occlusion, measured as Raymond-Roy class I, was achieved in all cases. CONCLUSION The SVB device was safely and effectively used in the treatment of PICA aneurysms. The smaller delivery system profile reduces the risk of procedure complications and creates new treatment options for distal lesions.
Collapse
Affiliation(s)
- Victor H C Benalia
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA.,Research Department, Jacksonville University, Jacksonville, Florida, USA
| | - Gustavo M Cortez
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA.,Research Department, Jacksonville University, Jacksonville, Florida, USA
| | - Leonardo B C Brasiliense
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA.,Department of Neurosurgery, College of Medicine Tucson, University of Arizona, Tucson, Arizona, USA
| | - Robert M Starke
- Department of Neurological Surgery, University of Miami School of Medicine, Miami, Florida, USA
| | - Monika Killer-Oberpfalzer
- Institute of Neurointervention/Department of Neurology, University Hospital Salzburg, Salzburg, Austria
| | - Demetrius K Lopes
- Brain and Spine Institute, Advocate Aurora Health, Chicago, Illinois, USA
| | - Peter T Kan
- Department of Neurosurgery, University of Texas Medical Branch, Galveston, Texas, USA
| | - Raul G Nogueira
- Neuroendovascular Service Marcus Stroke & Neuroscience Center, Grady Memorial Hospital, Atlanta, Georgia, USA
| | - Jeremiah N Johnson
- Department of Neurosurgery, University of California, Los Angeles, California, USA
| | - Vitor M Pereira
- Division of Neurosurgery, Departments of Surgery and Medical Imaging, St Michaels Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Craig Kilburg
- Neurosurgery Department, University of Utah Health, Salt Lake City, Utah, USA
| | - Susan Khalili
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA
| | - Ricardo A Hanel
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA
| |
Collapse
|