1
|
Fiedorova K, Augustynek M, Kubicek J, Kudrna P, Bibbo D. Review of present method of glucose from human blood and body fluids assessment. Biosens Bioelectron 2022; 211:114348. [DOI: 10.1016/j.bios.2022.114348] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 03/22/2022] [Accepted: 05/05/2022] [Indexed: 12/15/2022]
|
2
|
Andriankaja OM, Muñoz-Torres FJ, Vergara JL, Pérez CM, Joshipura K. Utility of point-of-care vs reference laboratory testing for the evaluation of glucose levels. Diabet Med 2019; 36:626-632. [PMID: 30710457 PMCID: PMC6599708 DOI: 10.1111/dme.13922] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/30/2019] [Indexed: 10/27/2022]
Abstract
AIMS To assess the level of agreement between point-of-care and laboratory reference glucose values in defining glycaemic status. METHODS We analysed 1292 overweight/obese, non-institutionalized participants, aged 40-65 years, in the San Juan Overweight Adults Longitudinal Study. Fasting venous blood glucose was determined using a point-of-care Bayer Contour Blood Glucose Meter and by Vitros System 250 instrument (laboratory). American Diabetes Association thresholds were used to classify participants into normoglycaemia (< 5.6 mmol/l), prediabetes (5.6 to 6.9 mmol/l), or diabetes groups (≥ 7 mmol/l). RESULTS Bland-Altman plot analysis showed a slope of 0.04 (P=0.002) for the regression between the mean difference and the average of the two methods. The slopes were significantly different from zero among people with normoglycaemia (β=-0.57, P<0.001), and prediabetes (β=-0.75, P<0.001) but not among people with diabetes (β=-0.02, P=0.68). When the prediabetes and diabetes groups were merged into one group, the slope was 0.01, and the glucose values remained similar using the two methods (P=0.76). CONCLUSION Point-of-care blood glucose measurement may be useful to screen people with diabetes, and to assess glucose among individuals with diabetes where blood can be drawn, but laboratory tests are unavailable or untimely.
Collapse
Affiliation(s)
- O M Andriankaja
- Center for Clinical Research and Health Promotion, School of Dental Medicine, University of Puerto Rico Medical Sciences Campus, San Juan, Puerto Rico
| | - F J Muñoz-Torres
- Center for Clinical Research and Health Promotion, School of Dental Medicine, University of Puerto Rico Medical Sciences Campus, San Juan, Puerto Rico
| | - J L Vergara
- Center for Clinical Research and Health Promotion, School of Dental Medicine, University of Puerto Rico Medical Sciences Campus, San Juan, Puerto Rico
| | - C M Pérez
- Department of Biostatistics and Epidemiology, School of Public Health, University of Puerto Rico Medical Sciences Campus, San Juan, Puerto Rico
| | - K Joshipura
- Center for Clinical Research and Health Promotion, School of Dental Medicine, University of Puerto Rico Medical Sciences Campus, San Juan, Puerto Rico
- Harvard T. H. Chan School of Public Health, Boston, MA, USA
| |
Collapse
|
3
|
Li FF, Xie Y, Shi BY, Niu M, Guo H, Cao Y, Liu BL, Yan RN, Su XF, Wu JD, Zhang DF, Chen LM, Ma JH. The real world of blood glucose point-of-care testing (POCT) system running in China teaching hospital. Expert Rev Med Devices 2018; 15:445-451. [PMID: 29737214 DOI: 10.1080/17434440.2018.1473031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND The blood glucose point-of-care testing (POCT) system is important in the decision-making process involving patients suspected of having hypoglycemia. To investigate the real world of the POCT system being used in teaching hospitals in China. METHODS The survey was conducted by Hisend Research Group from May 2015 to July 2015 in four teaching hospitals in China. The survey questions were referred to the ISO 15197:2013 standard requirements for the use of the POCT system in a hospital setting. RESULTS A total of 170 subjects were included from 4 hospitals, which included nursing staff, nurse unit managers, employees from the department of medical instruments, and staff members employed by the clinical laboratories in the Tianjin Metabolism Hospital, Nanjing First Hospital, First Affiliated Hospital of Dalian Medical University, and the First hospital affiliated with the Xi'an Transportation University. The average score for the four hospitals surveyed in this study was 66.6, which varied from 46.1 to 79.7. The main factors influencing the scores were the multiple choices of blood-glucose meters, and the quality control assessment. CONCLUSION Our data indicates that the real world use of the POCT system in hospital settings in China needs more closer adherence to a quality management framework.
Collapse
Affiliation(s)
- Feng-Fei Li
- a Department of Endocrinology , Nanjing First Hospital, Nanjing Medical University , Nanjing , China
| | - Yun Xie
- b 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Key Laboratory of Hormone and Development (Ministry of Health), Metabolic Disease Hospital & Tianjin Institute of Endocrinology , Tianjin Medical University , Tianjin , China
| | - Bing-Yin Shi
- c Department of Endocrinology , First Affiliated Hospital of Xi'an Jiaotong University , Xi'an , Shaanxi , China
| | - Min Niu
- d Department of Endocrinology , First Affiliated Hospital of Dalian Medical University , Dalian , China
| | - Hui Guo
- c Department of Endocrinology , First Affiliated Hospital of Xi'an Jiaotong University , Xi'an , Shaanxi , China
| | - Yan Cao
- a Department of Endocrinology , Nanjing First Hospital, Nanjing Medical University , Nanjing , China
| | - Bing-Li Liu
- a Department of Endocrinology , Nanjing First Hospital, Nanjing Medical University , Nanjing , China
| | - Reng-Na Yan
- a Department of Endocrinology , Nanjing First Hospital, Nanjing Medical University , Nanjing , China
| | - Xiao-Fei Su
- a Department of Endocrinology , Nanjing First Hospital, Nanjing Medical University , Nanjing , China
| | - Jin-Dan Wu
- a Department of Endocrinology , Nanjing First Hospital, Nanjing Medical University , Nanjing , China
| | - Dan-Feng Zhang
- a Department of Endocrinology , Nanjing First Hospital, Nanjing Medical University , Nanjing , China
| | - Li-Ming Chen
- b 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Key Laboratory of Hormone and Development (Ministry of Health), Metabolic Disease Hospital & Tianjin Institute of Endocrinology , Tianjin Medical University , Tianjin , China
| | - Jian-Hua Ma
- a Department of Endocrinology , Nanjing First Hospital, Nanjing Medical University , Nanjing , China
| |
Collapse
|
4
|
Füzéry AK, Cembrowski GS. Requirements for Successful Adoption of a Glucose Measurement System Into a Hospital POC Program. J Diabetes Sci Technol 2016; 10:947-9. [PMID: 27130460 PMCID: PMC4928240 DOI: 10.1177/1932296816645363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Widespread and successful implementation of any glucose measurement system in a hospital point-of-care (POC) program requires a number of features in addition to accurate and reliable analytical performance. Such features include, but are not limited to, a system's glucose-hematocrit dependence, durability, information technology capabilities, and battery capacity and battery life. While the study of Ottiger et al in this issue supports the analytical accuracy and reliability of Bayer's CONTOUR XT® blood glucose monitoring system, the suitability of other features of this system for a hospital POC program remains to be established.
Collapse
|