Liu Y, Zhang J, Chun X, Gao Y, Yao R, Liang Y, Zhu L, He Y, Huang W. Performance of continuous glucose monitoring in patients with acute respiratory failure: a prospective, single-center observational study. Endocr Pract 2024:S1530-891X(24)00557-3. [PMID: 38876178 DOI: 10.1016/j.eprac.2024.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 05/23/2024] [Accepted: 06/06/2024] [Indexed: 06/16/2024]
Abstract
OBJECTIVE Continuous glucose monitoring (CGM) may have benefits in achieving glycemic control in critically ill patients. The aim of this study was to assess the accuracy of the Freestyle Libre H (professional version of the Libre Pro). in patients with acute respiratory failure (ARF) in the intensive care unit (ICU). METHODS 52 adult patients with ARF were selected. The performance of CGM was evaluated using arterial blood glucose (aBG) and point-of-care (POC) glucose as reference values. Numerical accuracy was evaluated by the mean absolute relative difference (MARD), Bland-Altman analysis, and %15/15(the percentage of CGM values within 15 mg/dL or 15% of reference values <100 mg/dL or >100mg/dL, respectively), %20/20 and %30/30; Clinical accuracy was assessed by Clarke error grid analysis. RESULTS 519 and 1504 pairs of aBG/CGM and POC/CGM glucose values were analyzed. The MARD values were 13.8% and 14.7%, respectively. The mean deviation of the Bland‒Altman analysis was 0.82 mmol/L and 0.81 mmol/L. %15/15, %20/20 and %30/30 of aBG values were 62.6%, 75.5%, and 92.4%, respectively; %15/15, %20/20 and %30/30 of POC values were 57.1%, 72.9%, and 88.7%, respectively. The Clarke error grid analysis showed that 97.8% and 99.3% of the values located in the (A+B) zone. Additionally, accuracy of CGM is not affected by general patient factors. CONCLUSION This study demonstrated that the accuracy of CGM in patients with ARF is lower than that in most outpatients, and it is not affected by general patient factors. Whether CGM is beneficial to glucose management in ICU needs further evaluation.
Collapse
Affiliation(s)
- Yanhua Liu
- Department of Emergency Medicine, West China Hospital, Sichuan University / West China School of Nursing / Disaster Medicine Center, Sichuan University, Chengdu, China; Institute of Disaster Medicine, Sichuan University, Chengdu, China; Nursing Key Laboratory of Sichuan Province, Chengdu, China
| | - Jianna Zhang
- Department of Emergency Medicine, West China Hospital, Sichuan University / West China School of Nursing / Disaster Medicine Center, Sichuan University, Chengdu, China; Institute of Disaster Medicine, Sichuan University, Chengdu, China; Nursing Key Laboratory of Sichuan Province, Chengdu, China
| | - Xueli Chun
- Center of Gerontology and Geriatrics,West China Hospital, Sichuan University/ West China School of Nursing, Sichuan University, Chengdu, China
| | - Yongli Gao
- Department of Emergency Medicine, West China Hospital, Sichuan University / West China School of Nursing / Disaster Medicine Center, Sichuan University, Chengdu, China; Institute of Disaster Medicine, Sichuan University, Chengdu, China; Nursing Key Laboratory of Sichuan Province, Chengdu, China
| | - Rong Yao
- Department of Emergency Medicine, West China Hospital, Sichuan University / West China School of Nursing / Disaster Medicine Center, Sichuan University, Chengdu, China; Institute of Disaster Medicine, Sichuan University, Chengdu, China; Nursing Key Laboratory of Sichuan Province, Chengdu, China
| | - Yin Liang
- Department of Emergency Medicine, West China Hospital, Sichuan University / West China School of Nursing / Disaster Medicine Center, Sichuan University, Chengdu, China; Institute of Disaster Medicine, Sichuan University, Chengdu, China; Nursing Key Laboratory of Sichuan Province, Chengdu, China
| | - Ling Zhu
- Department of Emergency Medicine, West China Hospital, Sichuan University / West China School of Nursing / Disaster Medicine Center, Sichuan University, Chengdu, China; Institute of Disaster Medicine, Sichuan University, Chengdu, China; Nursing Key Laboratory of Sichuan Province, Chengdu, China
| | - Ying He
- Anesthesia & Operation Center, West China Hospital, Sichuan University/ West China School of Nursing, Sichuan University, Chengdu, China
| | - Wenxia Huang
- General Practice Medical Center, West China Hospital, Sichuan University/ West China School of Nursing, Sichuan University, Chengdu, China.
| |
Collapse
|
2
|
Spanakis EK, Cook CB, Kulasa K, Aloi JA, Bally L, Davis G, Dungan KM, Galindo RJ, Mendez CE, Pasquel FJ, Shah VN, Umpierrez GE, Aaron RE, Tian T, Yeung AM, Huang J, Klonoff DC. A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials. J Diabetes Sci Technol 2023; 17:1527-1552. [PMID: 37592726 PMCID: PMC10658683 DOI: 10.1177/19322968231191104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/19/2023]
Abstract
Diabetes Technology Society organized an expert consensus panel to develop metrics for research in the use of continuous glucose monitors (CGMs) in a hospital setting. The experts met virtually in small groups both before and after an April 13, 2023 virtual meeting of the entire panel. The goal of the panel was to develop consensus definitions in anticipation of greater use of CGMs in hospital settings in the future. Establishment of consensus definitions of inpatient analytical metrics will be easier to compare outcomes between studies. Panelists defined terms related to 10 dimensions of measurements related to the use of CGMs including (1) hospital hypoglycemia, (2) hospital hyperglycemia, (3) hospital time in range, (4) hospital glycemic variability, (5) hospital glycemia risk index, (6) accuracy of CGM devices and reference methods for CGMs in the hospital, (7) meaningful time blocks for hospital glycemic goals, (8) hospital CGM data sufficiency, (9) using CGM data for insulin dosing, and (10) miscellaneous factors. The panelists voted on 51 proposed recommendations. Based on the panel vote, 51 recommendations were classified as either strong (43) or mild (8). Additional research is needed on CGM performance in the hospital. This consensus report is intended to support that type of research intended to improve outcomes for hospitalized people with diabetes.
Collapse
Affiliation(s)
- Elias K. Spanakis
- Baltimore VA Medical Center, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Curtiss B. Cook
- Division of Endocrinology, Mayo Clinic Arizona, Scottsdale, AZ, USA
| | - Kristen Kulasa
- Division of Endocrinology and Metabolism, Department of Medicine, University of California, San Diego, La Jolla, CA, USA
| | - Joseph A. Aloi
- Atrium Health Wake Forest Baptist, Winston-Salem, NC, USA
| | - Lia Bally
- Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Georgia Davis
- Emory University School of Medicine, Atlanta, GA, USA
| | - Kathleen M. Dungan
- Division of Endocrinology, Diabetes & Metabolism, The Ohio State University, Columbus, OH, USA
| | | | | | | | - Viral N. Shah
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, CO, USA
| | | | | | - Tiffany Tian
- Diabetes Technology Society, Burlingame, CA, USA
| | | | | | - David C. Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA
| |
Collapse
|
3
|
Tian T, Aaron RE, Yeung AM, Huang J, Drincic A, Seley JJ, Wallia A, Gilbert G, Spanakis EK, Masharani U, Faulds E, Hirsch IB, Dawood GE, Espinoza JC, Mendez CE, Kerr D, Klonoff DC. Use of Continuous Glucose Monitors in the Hospital: The Diabetes Technology Society Hospital Meeting Report 2023. J Diabetes Sci Technol 2023; 17:1392-1418. [PMID: 37559371 PMCID: PMC10563530 DOI: 10.1177/19322968231186575] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/11/2023]
Abstract
The annual Virtual Hospital Diabetes Meeting was hosted by the Diabetes Technology Society on April 14 and 15, 2023, with the goal of reviewing the progress made in the hospital use of continuous glucose monitors (CGMs). Meeting topics included (1) Nursing Issues, Protocols, Order Sets, and Staff Education for Using CGMs, (2) Implementing CGM Programs for Use in the Wards, (3) Quality Metrics and Financial Implications of CGMs in the Hospital, (4) CGMs in the Critical Care Setting, (5) Special Situations: Labor/Delivery and Hemodialysis, (6) Research Session on CGMs in the Hospital, (7) Starting a CGM on Hospitalized Patients, (8) Automated Insulin Delivery Systems in the Hospital, (9) CGMs in Children, (10) Data Integration of CGMs for Inpatient Use and Telemetry, (11) Accuracy of CGMs/Comparison with Point-of-care Blood Glucose Testing, and (12) Discharge Planning with CGMs. Outcome data as well as shared collective real-life experiences were reviewed, and expert recommendations for CGM implementation were formulated.
Collapse
Affiliation(s)
- Tiffany Tian
- Diabetes Technology Society, Burlingame, CA, USA
| | | | | | | | | | | | - Amisha Wallia
- School of Medicine, Northwestern University Feinberg, Chicago, IL, USA
| | | | - Elias K. Spanakis
- Baltimore VA Medical Center and School of Medicine, University of Maryland, Baltimore, MD, USA
| | - Umesh Masharani
- University of California San Francisco, San Francisco, CA, USA
| | - Eileen Faulds
- College of Nursing and Wexner Medical Center, The Ohio State University, Columbus, OH, USA
| | - Irl B. Hirsch
- University of Washington Medicine Diabetes Institute, Seattle, WA, USA
| | - Gigi E. Dawood
- Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Juan C. Espinoza
- Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
- Ann & Robert H. Lurie Children’s Hospital of Chicago, Chicago, IL, USA
| | | | - David Kerr
- Diabetes Technology Society, Burlingame, CA, USA
| | - David C. Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA
| |
Collapse
|
4
|
Bellido V, Aguilera E, Cardona-Hernandez R, Diaz-Soto G, González Pérez de Villar N, Picón-César MJ, Ampudia-Blasco FJ. Expert Recommendations for Using Time-in-Range and Other Continuous Glucose Monitoring Metrics to Achieve Patient-Centered Glycemic Control in People With Diabetes. J Diabetes Sci Technol 2023; 17:1326-1336. [PMID: 35470692 PMCID: PMC10563535 DOI: 10.1177/19322968221088601] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
New metrics for assessing glycemic control beyond HbA1c have recently emerged due to the increasing use of continuous glucose monitoring (CGM) in diabetes clinical practice. Among them, time in range (TIR) has appeared as a simple and intuitive metric that correlates inversely with HbA1c and has also been newly linked to the risk of long-term diabetes complications. The International Consensus on Time in Range established a series of target glucose ranges (TIR, time below range and time above range) and recommendations for time spent within these ranges for different diabetes populations. These parameters should be evaluated together with the ambulatory glucose profile (AGP). Using standardized visual reporting may help people with diabetes and healthcare professionals in the evaluation of glucose control in frequent clinical situations. The objective of the present review is to provide practical insights to quick interpretation of patient-centered metrics based on flash glucose monitoring data, as well as showing some visual examples of common clinical situations and giving practical recommendations for their management.
Collapse
Affiliation(s)
- Virginia Bellido
- Unidad de Gestión Clínica de Endocrinología y Nutrición, Hospital Universitario Virgen del Rocío, Sevilla, Spain
| | - Eva Aguilera
- Endocrinology and Nutrition Department, Health Sciences Research Institute and University, Hospital Germans Trias i Pujol, Badalona, Spain
| | | | - Gonzalo Diaz-Soto
- Endocrinology and Nutrition Department, Hospital Clínico Universitario de Valladolid, Valladolid, Spain
- Universidad de Valladolid, Valladolid, Spain
| | | | - María J. Picón-César
- Endocrinology and Nutrition Department, Hospital Universitario Virgen de la Victoria, Málaga, Spain
- Instituto de Investigación Biomédica de Málaga, Málaga, Spain
- Centro de Investigación Biomédica en Red de Fisiopatología de la Obesidad y Nutrición, Instituto de Salud Carlos III, Madrid, Spain
| | - Francisco Javier Ampudia-Blasco
- Endocrinology and Nutrition Department, Hospital Clínico Universitario de Valencia, Valencia, Spain
- INCLIVA Research Foundation, Valencia, Spain
- CIBERDEM, Madrid, Spain
- Universitat de Valencia, Valencia, Spain
| |
Collapse
|
5
|
Jin Z, Thackray AE, King JA, Deighton K, Davies MJ, Stensel DJ. Analytical Performance of the Factory-Calibrated Flash Glucose Monitoring System FreeStyle Libre2 TM in Healthy Women. SENSORS (BASEL, SWITZERLAND) 2023; 23:7417. [PMID: 37687871 PMCID: PMC10490447 DOI: 10.3390/s23177417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 08/21/2023] [Accepted: 08/22/2023] [Indexed: 09/10/2023]
Abstract
Continuous glucose monitoring (CGM) is used clinically and for research purposes to capture glycaemic profiles. The accuracy of CGM among healthy populations has not been widely assessed. This study assessed agreement between glucose concentrations obtained from venous plasma and from CGM (FreeStyle Libre2TM, Abbott Diabetes Care, Witney, UK) in healthy women. Glucose concentrations were assessed after fasting and every 15 min after a standardized breakfast over a 4-h lab period. Accuracy of CGM was determined by Bland-Altman plot, 15/15% sensor agreement analysis, Clarke error grid analysis (EGA) and mean absolute relative difference (MARD). In all, 429 valid CGM readings with paired venous plasma glucose (VPG) values were obtained from 29 healthy women. Mean CGM readings were 1.14 mmol/L (95% CI: 0.97 to 1.30 mmol/L, p < 0.001) higher than VPG concentrations. Ratio 95% limits of agreement were from 0.68 to 2.20, and a proportional bias (slope: 0.22) was reported. Additionally, 45% of the CGM readings were within ±0.83 mmol/L (±15 mg/dL) or ±15% of VPG, while 85.3% were within EGA Zones A + B (clinically acceptable). MARD was 27.5% (95% CI: 20.8, 34.2%), with higher MARD values in the hypoglycaemia range and when VPG concentrations were falling. The FreeStyle Libre2TM CGM system tends to overestimate glucose concentrations compared to venous plasma samples in healthy women, especially during hypoglycaemia and during glycaemic swings.
Collapse
Affiliation(s)
- Zhuoxiu Jin
- National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough LE11 3TU, UK; (Z.J.); (A.E.T.); (J.A.K.)
| | - Alice E. Thackray
- National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough LE11 3TU, UK; (Z.J.); (A.E.T.); (J.A.K.)
- National Institute for Health and Care Research (NIHR) Leicester Biomedical Research Centre, University Hospitals of Leicester National Health Service (NHS) Trust and the University of Leicester, Leicester LE1 5WW, UK;
| | - James A. King
- National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough LE11 3TU, UK; (Z.J.); (A.E.T.); (J.A.K.)
- National Institute for Health and Care Research (NIHR) Leicester Biomedical Research Centre, University Hospitals of Leicester National Health Service (NHS) Trust and the University of Leicester, Leicester LE1 5WW, UK;
| | | | - Melanie J. Davies
- National Institute for Health and Care Research (NIHR) Leicester Biomedical Research Centre, University Hospitals of Leicester National Health Service (NHS) Trust and the University of Leicester, Leicester LE1 5WW, UK;
- Diabetes Research Centre, University of Leicester, Leicester LE5 4PW, UK
| | - David J. Stensel
- National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough LE11 3TU, UK; (Z.J.); (A.E.T.); (J.A.K.)
- National Institute for Health and Care Research (NIHR) Leicester Biomedical Research Centre, University Hospitals of Leicester National Health Service (NHS) Trust and the University of Leicester, Leicester LE1 5WW, UK;
- Faculty of Sport Sciences, Waseda University, Tokorozawa 359-1192, Japan
- Department of Sports Science and Physical Education, The Chinese University of Hong Kong, Ma Liu Shui, Hong Kong 999077, China
| |
Collapse
|
6
|
Santana D, Mosteiro A, Pedrosa L, Llull L, Torné R, Amaro S. Clinical relevance of glucose metrics during the early brain injury period after aneurysmal subarachnoid hemorrhage: An opportunity for continuous glucose monitoring. Front Neurol 2022; 13:977307. [PMID: 36172028 PMCID: PMC9512056 DOI: 10.3389/fneur.2022.977307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 08/25/2022] [Indexed: 11/13/2022] Open
Abstract
Hyperglycaemia, hypoglycaemia and higher glucose variability during the Early Brain Injury (EBI) period of aneurysmal subarachnoid hemorrhage (aSAH) have been associated with poor clinical outcome. However, it is unclear whether these associations are due to direct glucose-driven injury or if hyperglycaemia simply acts as a marker of initial severity. Actually, strict glucose control with intensive insulin therapy has not been demonstrated as an effective strategy for improving clinical outcomes after aSAH. Currently published studies describing an association between hyperglycaemia and prognosis in aSAH patients have been based on isolated glucose measurements and did not incorporate comprehensive dynamic evaluations, such as those derived from subcutaneous continuous glucose monitoring devices (CMG). Arguably, a more accurate knowledge on glycaemic patterns during the acute phase of aSAH could increase our understanding of the relevance of glycaemia as a prognostic factor in this disease as well as to underpin its contribution to secondary focal and diffuse brain injury. Herein, we have summarized the available evidence on the diagnostic and prognostic relevance of glucose metrics during the acute phase of cerebrovascular diseases, focusing in the EBI period after aSAH. Overall, obtaining a more precise scope of acute longitudinal glucose profiles could eventually be useful for improving glucose management protocols in the setting of acute aSAH and to advance toward a more personalized management of aSAH patients during the EBI phase.
Collapse
Affiliation(s)
- Daniel Santana
- Comprehensive Stroke Center, Institute of Neuroscience, Hospital Clinic of Barcelona, Barcelona, Spain
| | - Alejandra Mosteiro
- Neurosurgery Department, Institute of Neuroscience, Hospital Clinic of Barcelona, Barcelona, Spain
| | - Leire Pedrosa
- Institut d'Investigacions Biomèdiques Agustí Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Laura Llull
- Comprehensive Stroke Center, Institute of Neuroscience, Hospital Clinic of Barcelona, Barcelona, Spain
- Institut d'Investigacions Biomèdiques Agustí Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Ramón Torné
- Neurosurgery Department, Institute of Neuroscience, Hospital Clinic of Barcelona, Barcelona, Spain
- Institut d'Investigacions Biomèdiques Agustí Pi i Sunyer (IDIBAPS), Barcelona, Spain
- Department of Medicine, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
- *Correspondence: Ramón Torné
| | - Sergi Amaro
- Comprehensive Stroke Center, Institute of Neuroscience, Hospital Clinic of Barcelona, Barcelona, Spain
- Institut d'Investigacions Biomèdiques Agustí Pi i Sunyer (IDIBAPS), Barcelona, Spain
- Department of Medicine, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
- Sergi Amaro
| |
Collapse
|
7
|
Moscardó V, Garcia A, Bondia J, Diaz J, Ramos-Prol A, Rossetti P. Effect of Ethanol Consumption on the Accuracy of a Glucose Oxidase-Based Subcutaneous Glucose Sensor in Subjects with Type 1 Diabetes. SENSORS (BASEL, SWITZERLAND) 2022; 22:3101. [PMID: 35590791 PMCID: PMC9104985 DOI: 10.3390/s22093101] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 04/12/2022] [Accepted: 04/15/2022] [Indexed: 06/15/2023]
Abstract
Continuous glucose monitors (CGM) have improved the management of patients with type 1 diabetes (T1D), with glucose oxidase (GOx)-based sensors being the most used. However, they are potentially subject to both electrochemical and enzymatic interferences, including those related to changes of pH. The objective of this study is to investigate the effect of ethanol, given as beer along with a mixed meal, on the accuracy of a commercial GOx-CGM. Data from 12 T1D participants in a randomized crossover trial to evaluate the effect of meal composition and alcohol consumption on postprandial glucose concentration were used. Absolute error (AE) and mean absolute relative difference (MARD) were calculated. The differences between the alcohol and nonalcohol scenarios were assessed using the Mann−Whitney U and Wilcoxon signed-rank tests. The AE in the alcohol study was low, but significantly greater as compared to the study without alcohol (p-value = 0.0418). The MARD was numerically but not significantly greater. However, both variables were greater at pH < 7.36 and significantly affected by time only in the alcohol arm. In T1D, alcohol consumption affects the accuracy of a GOx-CGM. This effect could be at least partially related to the ethanol-induced changes in pH.
Collapse
Affiliation(s)
- Vanessa Moscardó
- Facultad de Ciencia y Tecnología, Universidad Internacional de Valencia, 46002 Valencia, Spain
| | - Alia Garcia
- Department of Endocrinology, University Hospital of La Ribera, 46600 Alzira, Spain;
| | - Jorge Bondia
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, 46022 Valencia, Spain;
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM)—Grupo CB17/08/00004, Instituto de Salud Carlos III, 41092 Madrid, Spain;
| | - Julián Diaz
- Hospital Francesc de Borja, 46702 Gandia, Spain; (J.D.); (A.R.-P.)
| | | | - Paolo Rossetti
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM)—Grupo CB17/08/00004, Instituto de Salud Carlos III, 41092 Madrid, Spain;
- Department of Endocrinology, Hospital Universitari i Politècnic La Fe, 46026 Valencia, Spain
| |
Collapse
|