1
|
A Selective and Sensitive LC-MS/MS Method for Quantitation of Indole in Mouse Serum and Tissues. Metabolites 2022; 12:metabo12080716. [PMID: 36005588 PMCID: PMC9416675 DOI: 10.3390/metabo12080716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 07/22/2022] [Accepted: 07/25/2022] [Indexed: 12/04/2022] Open
Abstract
Indole is an endogenous substance currently being evaluated as a biomarker for ulcerative colitis, irritable bowel syndrome, Crohn’s disease and non-alcoholic fatty liver disease. A novel, selective, and sensitive method using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed for quantitation of indole concentrations in mouse plasma and tissues. Samples were prepared by protein precipitation using ice-cold acetonitrile (ACN) followed by injecting the extracted analyte to LC-MS/MS system. Indole was separated using Synergi Fusion C18 (4 µm, 250 × 2.0 mm) column with mobile phase 0.1% aqueous formic acid (A) and methanol (B) using gradient flow with run time 12 min. The mass spectrometer was operated in atmospheric pressure chemical ionization (APCI) positive mode at unit resolution in multiple reaction monitoring (MRM) mode, using precursor ion > product ion combinations of 118.1 > 91.1 m/z for indole and 124.15 > 96.1 m/z for internal standard (IS) indole d7. The MS/MS response was linear over the range of indole concentrations (1−500 ng/mL). The validated method was applied for quantitation of indole concentrations range in mouse lungs (4.3−69.4 ng/g), serum (0.8−38.7 ng/mL) and cecum (1043.8−12,124.4 ng/g). This method would help investigate the role of indole as a biomarker and understand its implications in different disease states.
Collapse
|
2
|
Fang H, Wu M, Ji W, Wang L, Chen Y, Chen D, Yang N, Wu Q, Yu C, Liu J, Liu J, Bai H, Peng B, Huang X, Yu HD, Li L. Simultaneously Detecting Monoamine Oxidase A and B in Disease Cell/Tissue Samples Using Paper-Based Devices. ACS APPLIED BIO MATERIALS 2021; 4:1395-1402. [PMID: 35014490 DOI: 10.1021/acsabm.0c01288] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
As enzymes in the outer membrane of the mitochondrion, monoamine oxidases (MAOs) can catalyze the oxidative deamination of monoamines in the human body. According to different substrates, MAOs can be divided into MAO-A and MAO-B. The imbalance of the MAO-A is associated with neurological degeneration, while excess MAO-B activity is closely connected with Parkinson's disease (PD) and Alzheimer's disease (AD); therefore, detection of MAOs is of great significance for the diagnosis and treatment of these diseases. This work reports the multiplexed detection of MAO-A and MAO-B using paper-based devices based on chemiluminescence (CL). The detection limits were 5.01 pg/mL for MAO-A and 8.50 pg/mL for MAO-B in human serum. In addition, we used paper-based devices to detect MAOs in human cells and tissue samples and found that the results of paper-based detection and Western blotting (WB) showed the same trend. While only one antibody can be incubated on the same membrane by WB, multiple antibodies incubated on the same paper enabled simultaneous detection of MAO-A and MAO-B by paper-based devices. The paper-based assay could be used for preliminary early screening of clinical samples for MAOs and can be extended as an alternative to WB for multiplexed detection of various proteins in disease cell or tissue samples.
Collapse
Affiliation(s)
- Haixiao Fang
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Meirong Wu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Wenhui Ji
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Limin Wang
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Yipei Chen
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Ding Chen
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Naidi Yang
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Qiong Wu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Changmin Yu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Jie Liu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Jinhua Liu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Hua Bai
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Bo Peng
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Xiao Huang
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Hai-Dong Yu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China.,Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Lin Li
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| |
Collapse
|