1
|
Sanders JE, Vamos AC, Mertens JC, Allyn KJ, Larsen BG, Ballesteros D, Wang H, DeGrasse NS, Garbini JL, Hafner BJ, Friedly JL. An adaptive prosthetic socket for people with transtibial amputation. Sci Rep 2024; 14:11168. [PMID: 38750086 PMCID: PMC11096356 DOI: 10.1038/s41598-024-61234-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 05/01/2024] [Indexed: 05/18/2024] Open
Abstract
It is essential that people with limb amputation maintain proper prosthetic socket fit to prevent injury. Monitoring and adjusting socket fit, for example by removing the prosthesis to add prosthetic socks, is burdensome and can adversely affect users' function and quality-of-life. This study presents results from take-home testing of a motor-driven adaptive socket that automatically adjusted socket size during walking. A socket fit metric was calculated from inductive sensor measurements of the distance between the elastomeric liner surrounding the residual limb and the socket's inner surface. A proportional-integral controller was implemented to adjust socket size. When tested on 12 participants with transtibial amputation, the controller was active a mean of 68% of the walking time. In general, participants who walked more than 20 min/day demonstrated greater activity, less doff time, and fewer manual socket size adjustments for the adaptive socket compared with a locked non-adjustable socket and a motor-driven socket that participants adjusted with a smartphone application. Nine of 12 participants reported that they would use a motor-driven adjustable socket if it were available as it would limit their socket fit issues. The size and weight of the adaptive socket were considered the most important variables to improve.
Collapse
Affiliation(s)
- Joan E Sanders
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA, 98195, USA.
| | - Andrew C Vamos
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA, 98195, USA
| | - Joseph C Mertens
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA, 98195, USA
| | - Katheryn J Allyn
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA, 98195, USA
| | - Brian G Larsen
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA, 98195, USA
| | - Daniel Ballesteros
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA, 98195, USA
| | - Horace Wang
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA, 98195, USA
| | - Nicholas S DeGrasse
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA, 98195, USA
| | - Joseph L Garbini
- Department of Mechanical Engineering, University of Washington, 3900 E Stevens Way NE, Box 352600, Seattle, WA, 98195, USA
| | - Brian J Hafner
- Department of Rehabilitation Medicine, University of Washington, 1959 NE Pacific St, Box 356490, Seattle, WA, 98195, USA
| | - Janna L Friedly
- Department of Rehabilitation Medicine, University of Washington, 325 Ninth Ave, Box 359612, Seattle, WA, 98104, USA
| |
Collapse
|
2
|
Mollaee S, Fuentes-Aguilar RQ, Huegel JC, Budgett DM, Taberner AJ, Nielsen PMF. A pneumatic reconfigurable socket for transtibial amputees. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3801. [PMID: 38185908 DOI: 10.1002/cnm.3801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 11/06/2023] [Accepted: 12/07/2023] [Indexed: 01/09/2024]
Abstract
Many transtibial amputees rate the fit between their residual limb and prosthetic socket as the most critical factor in satisfaction with using their prosthesis. This study aims to address the issue of prosthetic socket fit by reconfiguring the socket shape at the interface of the residual limb and socket. The proposed reconfigurable socket shifts pressure from sensitive areas and compensates for residual limb volume fluctuations, the most important factors in determining a good socket fit. Computed tomography scan images are employed to create the phantom limb of an amputee and to manufacture the reconfigurable socket. The performance of the reconfigurable socket was evaluated both experimentally and numerically using finite element modelling. The study showed that the reconfigurable socket can reduce interface pressure at targeted areas by up to 61%.
Collapse
Affiliation(s)
- Saeed Mollaee
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Rita Q Fuentes-Aguilar
- Institute of Advanced Materials for Sustainable Manufacturing, Tecnologico de Monterrey, Zapopan, Mexico
| | - Joel C Huegel
- School of Engineering and Sciences, Tecnologico de Monterrey, Zapopan, Mexico
| | - David M Budgett
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Andrew J Taberner
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
- Department of Engineering Science and Biomedical Engineering, The University of Auckland, Auckland, New Zealand
| | - Poul M F Nielsen
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
- Department of Engineering Science and Biomedical Engineering, The University of Auckland, Auckland, New Zealand
| |
Collapse
|