Mohamed AMA, Askar MG, El Homossany MEMB. Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study.
BMC Oral Health 2022;
22:196. [PMID:
35599323 PMCID:
PMC9125928 DOI:
10.1186/s12903-022-02228-9]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Accepted: 05/11/2022] [Indexed: 11/10/2022] Open
Abstract
Background
Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® concept and the conventional two piece ones under simulated lateral occlusal schemes using nonlinear finite element analysis.
Methods
Two finite element models of the maxilla, implants, and prostheses were designed according to the All-on-4® concept. In the model TP, two piece dental implants were placed while in the model OP one piece dental implants were used. Two loading scenarios were applied to each model; the first one simulated a group function occlusal scheme while the second scenario simulated a canine guided one.
Results
The highest stress value was recorded in the model TP with the group function occlusion and the lowest stress value was in the model OP with the canine guidance occlusion.
Conclusion
The one-piece dental implants can be concluded to induce less stress compared to the two piece dental implants when used in the All-on-4® implant supported prosthesis in the different lateral occlusal schemes. Canine guided occlusion can be concluded to cause lower stress values in comparison to the group function occlusal scheme.
Collapse