Iwasaka-Neder J, Bedoya MA, Connors J, Warfield S, Bixby SD. Morphometric and clinical comparison of MRI-based synthetic CT to conventional CT of the hip in children.
Pediatr Radiol 2024;
54:743-757. [PMID:
38421417 DOI:
10.1007/s00247-024-05888-7]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 02/03/2024] [Accepted: 02/15/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND
MRI-based synthetic CT (sCT) generates CT-like images from MRI data.
OBJECTIVE
To evaluate equivalence, inter- and intraobserver reliability, and image quality of sCT compared to conventional (cCT) for assessing hip morphology and maturity in pediatric patients.
MATERIALS AND METHODS
We prospectively enrolled patients <21 years old with cCT and 3T MRI of the hips/pelvis. A dual-echo gradient-echo sequence was used to generate sCT via a commercially available post-processing software (BoneMRI v1.5 research version, MRIguidance BV, Utrecht, NL). Two pediatric musculoskeletal radiologists measured seven morphologic hip parameters. 3D surface distances between cCT and sCT were computed. Physeal status was established at seven locations with cCT as reference standard. Images were qualitatively scored on a 5-point Likert scale regarding diagnostic quality, signal-to-noise ratio, clarity of bony margin, corticomedullary differentiation, and presence and severity of artifacts. Quantitative evaluation of Hounsfield units (HU) was performed in bone, muscle, and fat tissue. Inter- and intraobserver reliability were measured by intraclass correlation coefficients. The cCT-to-sCT intermodal agreement was assessed via Bland-Altman analysis. The equivalence between modalities was tested using paired two one-sided tests. The quality parameter scores of each imaging modality were compared via Wilcoxon signed-rank test. For tissue-specific HU measurements, mean absolute error and mean percentage error values were calculated using the cCT as the reference standard.
RESULTS
Thirty-eight hips in 19 patients were included (16.6 ± 3 years, range 9.9-20.9; male = 5). cCT- and sCT-based morphologic measurements demonstrated good to excellent inter- and intraobserver correlation (0.77
CONCLUSION
sCT is equivalent to cCT for the assessment of hip morphology, physeal status, and radiodensity assessment in pediatric patients.
Collapse
Affiliation(s)
- Jade Iwasaka-Neder
- Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA.
| |
- M Alejandra Bedoya
- Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA
| |
- James Connors
- Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA
| |
- Simon Warfield
- Computational Radiology Laboratory, Boston Children's Hospital, 401 Park Drive, Boston, MA, 02215, USA
| |
- Sarah D Bixby
- Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA
| |
Collapse