1
|
Almutleb ES, Ramachandran S, Khan AA, El-Hiti GA, Alanazi SA. Synergistic Effect of Nilavembu Choornam-Gold Nanoparticles on Antibiotic-Resistant Bacterial Susceptibility and Contact Lens Contamination-Associated Infectious Pathogenicity. Int J Mol Sci 2024; 25:2115. [PMID: 38396792 PMCID: PMC10889799 DOI: 10.3390/ijms25042115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 01/31/2024] [Accepted: 02/06/2024] [Indexed: 02/25/2024] Open
Abstract
Antibiotic-resistant bacterial colonies mitigate rapid biofilm formation and have complex cell wall fabrications, making it challenging to penetrate drugs across their biofilm barriers. The objective of this study was to investigate the antibacterial susceptibility of antibiotic-resistant bacteria and contact lens barrenness. Nilavembu Choornam-Gold Nanoparticles (NC-GNPs) were synthesized using NC polyherbal extract and characterized by UV-visible spectrophotometer, SEM-EDX, XRD, Zeta sizer, FTIR, and TEM analysis. Contact lenses with overnight cultures of antibiotic-resistant bacteria K. pneumoniae and S. aureus showed significant differences in growth, biofilm formation, and infection pathogenicity. The NC-GNPs were observed in terms of size (average size is 57.6 nm) and surface chemistry. A zone of inhibition was calculated for K. pneumoniae 18.8 ± 1.06, S. aureus 23.6 ± 1.15, P. aeruginosa 24.16 ± 0.87, and E. faecalis 24.5 ± 1.54 mm at 24 h of NC-GNPs alone treatment. In electron microscopy studies, NC-GNP-treated groups showed nuclear shrinkage, nuclear disintegration, degeneration of cell walls, and inhibited chromosomal division. In contrast, normal bacterial colonies had a higher number of cell divisions and routinely migrated toward cell multiplications. NC-GNPs exhibited antibacterial efficacy against antibiotic-resistant bacteria when compared to NC extract alone. We suggest that NC-GNPs are highly valuable to the population of hospitalized patients and other people to reduce the primary complications of contact lens contamination-oriented microbial infection and the therapeutic efficiency of antibiotic-resistant bacterial pathogenicity.
Collapse
Affiliation(s)
| | - Samivel Ramachandran
- Cornea Research Chair, Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh 11433, Saudi Arabia; (E.S.A.); (A.A.K.); (G.A.E.-H.); (S.A.A.)
| | | | | | | |
Collapse
|
2
|
Abstract
ABSTRACT Contact lenses are a safe and effective method for correction of refractive error and worn by an estimated 45 million Americans. Because of the widespread availability and commercial popularity of contact lenses, it is not well appreciated by the public that contact lenses are U.S. Food and Drug Administration (FDA)-regulated medical devices. Contact lenses are marketed in numerous hard and soft materials that have been improved over decades, worn in daily or extended wear, and replaced in range of schedules from daily to yearly or longer. Lens materials and wear and care regimens have impact on the risks of contact lens-related corneal inflammatory events and microbial keratitis. This article reviews contact lens safety, with specific focus on the correction of refractive error in healthy eyes.
Collapse
|
3
|
Lourenco Nogueira C, Boegel SJ, Shukla M, Ngo W, Jones L, Aucoin MG. Antiviral Activity of Contemporary Contact Lens Care Solutions against Two Human Seasonal Coronavirus Strains. Pathogens 2022; 11:472. [PMID: 35456147 PMCID: PMC9026382 DOI: 10.3390/pathogens11040472] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 04/04/2022] [Accepted: 04/12/2022] [Indexed: 02/04/2023] Open
Abstract
Background: Given that reports have suggested SARS-CoV-2 can be transmitted via conjunctiva, the ability of contact lens (CL) care products to reduce the infectiousness of two seasonal human coronavirus (HCoV) (HCoV-229E and HCoV-OC43) surrogates for SARS-CoV-2 was investigated. Methods: Biotrue and Boston Simplus (Bausch&Lomb), OPTI-FREE Puremoist and Clear Care (Alcon), and cleadew and cleadew GP (Ophtecs) were tested. Their ability to inactivate HCoV was evaluated using contact times of 4 and 6 h as well as 1% and 10% of virus inoculum. Results: Non-oxidative systems (Biotrue, Boston Simplus, and OPTI-FREE) did not exhibit a significant log10 reduction compared to controls for the two viral strains for either incubation time (all p > 0.05) when 10% tests were performed. For the 1% test, while Boston Simplus and OPTI-FREE exhibited a significant log10 reduction of both HCoV-229E (after 6 h) and HCoV-OC43 (after either 4 or 6 h incubation), those products showed less than 1 log10 reduction of the two infectious viruses. Oxidative systems based on hydrogen peroxide or povidone-iodine showed a significant log10 reduction compared with the controls for both HCoV-229E and HCoV-OC43 in all tested conditions (all p < 0.01). Clear Care led to virus inactivation to below the limit of quantification for tests performed with 1% of inoculum after 6 h incubation, while cleadew and cleadew GP led to inactivation of the two viruses to below the limit of quantification in all tested conditions. Conclusion: Oxidative CL disinfection systems showed significant virucidal activity against HCoV-229E and HCoV-OC43, while non-oxidative systems showed minimal ability to inactivate the HCoV species examined.
Collapse
Affiliation(s)
| | - Scott Joseph Boegel
- Department of Chemical Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada; (C.L.N.); (S.J.B.)
| | - Manish Shukla
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON N2L 3G1, Canada; (M.S.); (W.N.); (L.J.)
- Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON N2L 3G1, Canada; (M.S.); (W.N.); (L.J.)
- Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON N2L 3G1, Canada; (M.S.); (W.N.); (L.J.)
- Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| | - Marc G. Aucoin
- Department of Chemical Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada; (C.L.N.); (S.J.B.)
| |
Collapse
|
4
|
ALIMU YIKELAMU, KUSUYA YOKO, YAMAMOTO TAKAKO, ARITA KANA, SHIGEMUNE NAOFUMI, TAKAHASHI HIROKI, YAGUCHI TAKASHI. Mechanism of Polyhexamethylene Biguanide Resistance in <i>Purpureocillium lilacinum</i> Strains. Biocontrol Sci 2022; 27:117-130. [DOI: 10.4265/bio.27.117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Affiliation(s)
| | | | | | - KANA ARITA
- R&D-Safety Science Research, Kao Corporation
| | | | | | | |
Collapse
|
5
|
Goble BJ, Boyd JD, Grady ME. Exploring microwave irradiation as a method to disinfect contact lens cases. Cont Lens Anterior Eye 2021; 45:101522. [PMID: 34642118 PMCID: PMC8993943 DOI: 10.1016/j.clae.2021.101522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 08/24/2021] [Accepted: 09/28/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE Biofilm formation caused by infrequent contact lens case replacement and the ineffectiveness of multi-purpose solutions (MPS) on biofilm removal is associated with high rates of bacterial keratitis infections. This study demonstrated biofilm elimination from the contact lens case by microwave irradiation. METHODS Staphylococcus aureus biofilms indicative of 3-9 months of contact wear were cultured in contact lens cases and visualized with crystal violet (CV) staining. Biofilms in contact cases were then exposed to four treatment regimens: No treatment (n = 8), 45 s microwave irradiation (n = 8), tap water (n = 6), and MPS (n = 9). Bacterial survival was assessed by colony forming unit (CFU) assay using streak dilutions. RESULTS Visualization of the biofilms through CV staining revealed that biofilms coalesce between ribs of the contact case. In 5/8 cases no CFU were cultivated from the case after treatment with microwave irradiation. In tap water and MPS the first dilution averaged 6 ± 2 and 31 ± 13 CFUs per plate, respectively, while microwave irradiation averaged < 1 CFU per plate. In Dilution 2, the average reduced to 0.7 ± 0.7 and 6 ± 5 CFUs per plate for tap water and MPS, respectively, while microwave irradiation had 0 CFUs in Dilution 2. CONCLUSION Biofilms that coalesce between the ribs of the contact case pose a threat because this area is difficult to thoroughly scrub and could act as a basis for infection through fouling of contact lenses. Of the four treatment regimens, microwave irradiation displayed the most consistent and highest rate of bacterial eradication. Tap water was less effective compared to microwave irradiation, and poses other harmful side effects, but greatly reduced CFU count compared to no treatment. MPS displayed the poorest bacterial eradication of the treatments. Thus, microwave irradiation is worth further investigation as a viable in-home disinfecting option.
Collapse
Affiliation(s)
- Brandon J Goble
- Agriculture and Medical Biotechnology, College of Agriculture, Food, and Environment, University of Kentucky, 506 Administration Drive, Lexington, KY 40506, United States; Department of Mechanical Engineering, College of Engineering, University of Kentucky, 506 Administration Drive, Lexington, KY, 40506, United States
| | - James D Boyd
- Department of Mechanical Engineering, College of Engineering, University of Kentucky, 506 Administration Drive, Lexington, KY, 40506, United States
| | - Martha E Grady
- Department of Mechanical Engineering, College of Engineering, University of Kentucky, 506 Administration Drive, Lexington, KY, 40506, United States.
| |
Collapse
|
6
|
Hoenes K, Wenzel U, Hessling M. Realisation and assessment of a low-cost LED device for contact lens disinfection by visible violet light. ACTA ACUST UNITED AC 2021; 65:485-490. [PMID: 31809261 DOI: 10.1515/bmt-2019-0231] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Accepted: 10/25/2019] [Indexed: 12/26/2022]
Abstract
This study presents a device for efficient, low-cost and eye-friendly overnight disinfection of contact lenses by visible violet light as an alternative to disinfection with biocide-containing solutions. Bacterial solutions with one Pseudomonas and one Staphylococcus strain each were irradiated for up to 8 h in commercial transparent contact lens cases by the presented light-emitting diode (LED) device. Samples were taken at different intervals and distributed on agar plates. The surviving bacteria were determined by counting of colony-forming units and compared to the specific requirements of the stand-alone test for contact lens disinfection of the hygiene standard ISO 14729. The concentration of both microorganisms was reduced by three orders of magnitude after less than 4 h of irradiation. The LED current and intensity have not yet been at maximum and could be further increased if necessary for other microorganisms. The presented device fulfils the requirement of the stand-alone test of the contact lens hygienic standard ISO 14729 for the tested Pseudomonas and Staphylococcus strains. According to literature data, the inactivation of Serratia marcescens, Candida albicans and Fusarium solani seems also possible, but may require increased LED current and intensity.
Collapse
Affiliation(s)
- Katharina Hoenes
- Ulm University of Applied Sciences, Institute of Medical Engineering and Mechatronics, Albert-Einstein-Allee 55, D-89081 Ulm, Germany
| | - Ulla Wenzel
- Ulm University of Applied Sciences, Institute of Medical Engineering and Mechatronics, Albert-Einstein-Allee 55, D-89081 Ulm, Germany
| | - Martin Hessling
- Ulm University of Applied Sciences, Institute of Medical Engineering and Mechatronics, Albert-Einstein-Allee 55, D-89081 Ulm, Germany
| |
Collapse
|
7
|
Vincent SJ, Cho P, Chan KY, Fadel D, Ghorbani-Mojarrad N, González-Méijome JM, Johnson L, Kang P, Michaud L, Simard P, Jones L. CLEAR - Orthokeratology. Cont Lens Anterior Eye 2021; 44:240-269. [DOI: 10.1016/j.clae.2021.02.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/25/2022]
|
8
|
Yee A, Walsh K, Schulze M, Jones L. The impact of patient behaviour and care system compliance on reusable soft contact lens complications. Cont Lens Anterior Eye 2021; 44:101432. [PMID: 33678542 DOI: 10.1016/j.clae.2021.02.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 01/07/2021] [Accepted: 02/23/2021] [Indexed: 11/19/2022]
Abstract
Reusable soft daily wear contact lenses (CLs) remain popular and were fit to just over half of all wearers in the most recent international CL prescribing survey. Unlike daily disposable CLs, reusables require cleaning and disinfecting after every use, along with storage in a CL case. These additional requirements add a number of steps to the daily wear and care routine, increasing the opportunities for CL wearers to exhibit non-compliant behaviour. The impact of non-compliance ranges from poor lens comfort through to potentially sight-threatening infective keratitis. The coronavirus pandemic has refocused the profession on the importance of hand hygiene in particular, and the need for promoting safe CL wear in general. This review summarises typical non-compliant behaviour related to reusable CLs, and examines strategies and opportunities to better support wearers. Patient education has a central role in encouraging compliant behaviour, although patient recall of information is low, and personal belief systems may result in continuation of non-compliant behaviour despite awareness of the risks. CL care solutions are required for the daily disinfection of lenses, however misuse of multipurpose solutions (MPS) and hydrogen peroxide (H2O2)-based care systems can challenge their ability to be fully efficacious. Standard efficacy testing is reviewed, with consideration of how well current protocols model real-world use of CL solutions. Although some recommendations are in place for the inclusion of additional variables such as lens cases, CL materials, organic soil and efficacy against Acanthamoeba, opportunity still exists to reevaluate global standards to ensure consistency of testing in all markets. Finally, potential future innovations are discussed which may further support increased safety in reusable lens wear through novel antimicrobial additions to both CL materials and cases.
Collapse
Affiliation(s)
- Alan Yee
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Canada.
| | - Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Canada.
| | - Marc Schulze
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Canada.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Canada.
| |
Collapse
|
9
|
Yamasaki K, Mizuno Y, Kitamura Y, McCanna DJ, Ngo W, Jones LW. The efficacy of povidone-iodine, hydrogen peroxide and a chemical multipurpose contact lens care system against Pseudomonas aeruginosa on various lens case surfaces. Cont Lens Anterior Eye 2021; 44:18-23. [DOI: 10.1016/j.clae.2020.02.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 02/18/2020] [Accepted: 02/20/2020] [Indexed: 10/24/2022]
|
10
|
Sowlati-Hashjin S, Carbone P, Karttunen M. Insights into the Polyhexamethylene Biguanide (PHMB) Mechanism of Action on Bacterial Membrane and DNA: A Molecular Dynamics Study. J Phys Chem B 2020; 124:4487-4497. [DOI: 10.1021/acs.jpcb.0c02609] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Affiliation(s)
- Shahin Sowlati-Hashjin
- Department of Chemistry, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada
- The Centre of Advanced Materials and Biomaterials Research, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada
| | - Paola Carbone
- Department of Chemical Engineering and Analytical Science, The University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| | - Mikko Karttunen
- Department of Chemistry, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada
- The Centre of Advanced Materials and Biomaterials Research, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada
- Department of Applied Mathematics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada
| |
Collapse
|
11
|
Shayani Rad M, Sabeti Z, Mohajeri SA, Fazly Bazzaz BS. Preparation, Characterization, and Evaluation of Zinc Oxide Nanoparticles Suspension as an Antimicrobial Media for Daily Use Soft Contact Lenses. Curr Eye Res 2020; 45:931-939. [DOI: 10.1080/02713683.2019.1705492] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Maryam Shayani Rad
- Student Research Committee (SRC), Mashhad University of Medical Sciences, Mashhad, Iran
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Zahra Sabeti
- Biotechnology Research Center, Pharmaceutical Research Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Seyed Ahmad Mohajeri
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Pharmacodynamics and Toxicology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Bibi Sedigheh Fazly Bazzaz
- Biotechnology Research Center, Pharmaceutical Research Institute, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Pharmaceutical Control, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
12
|
Di Onofrio V, Gesuele R, Maione A, Liguori G, Liguori R, Guida M, Nigro R, Galdiero E. Prevention of Pseudomonas aeruginosa Biofilm Formation on Soft Contact Lenses by Allium sativum Fermented Extract (BGE) and Cannabinol Oil Extract (CBD). Antibiotics (Basel) 2019; 8:antibiotics8040258. [PMID: 31835470 PMCID: PMC6963262 DOI: 10.3390/antibiotics8040258] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 12/03/2019] [Accepted: 12/09/2019] [Indexed: 01/09/2023] Open
Abstract
Two natural mixtures, Allium sativum fermented extract (BGE) and cannabinol oil extract (CBD), were assessed for their ability to inhibit and remove Pseudomonas aeruginosa biofilms on soft contact lenses in comparison to a multipurpose Soft Contact Lens-care solution present on the Italian market. Pseudomonas aeruginosa (ATCC 9027 strain) and Pseudomonas aeruginosa clinical strains isolated from ocular swabs were tested. Quantification of the biofilm was done using the microtiter plate assay and the fractional inhibitory concentration index was calculated. Both forms of Pseudomonas aeruginosa generated biofilms. BGE at minimal inhibitory concentration (MIC) showed inhibition percentages higher than 55% for both strains, and CBD inhibited biofilm formation by about 70%. The care solution at MIC inhibited biofilm formation by about 50% for both strains tested. The effect of BGE on the eradication of the microbial biofilm on soft contact lenses at MIC was 45% eradication for P. aeruginosa ATCC 9027 and 36% for P. aeruginosa clinical strain. For CBD, we observed 24% biofilm eradication for both strains. For the care solution, the eradication MICs were 43% eradication for P. aeruginosa ATCC 9027 and 41% for P. aeruginosa clinical strain. It was observed that both the test soft contact lenses solution/BGE (fractional inhibitory concentration index: 0.450) and the test soft contact lenses solution/CBD (fractional inhibitory concentration index: 0.153) combinations exhibited synergistic antibiofilm activity against most of the studied bacteria. The study showed that BGE and CBD have good effect on inhibition of biofilm formation and removal of preformed biofilms, which makes them promising agents that could be exploited to develop more effective care solutions.
Collapse
Affiliation(s)
- Valeria Di Onofrio
- Department of Sciences and Technologies, University of Naples “Parthenope”, Business District, Block C4, 80143 Naples, Italy;
- Correspondence:
| | - Renato Gesuele
- Department of Biology, University of Naples “Federico II”, Via Cinthia, 80126 Naples, Italy; (R.G.); (A.M.); (M.G.); (E.G.)
| | - Angela Maione
- Department of Biology, University of Naples “Federico II”, Via Cinthia, 80126 Naples, Italy; (R.G.); (A.M.); (M.G.); (E.G.)
| | - Giorgio Liguori
- Department of Movement Sciences and Wellbeing, University of Naples “Parthenope”, Via Medina 40, 80133 Naples, Italy;
| | - Renato Liguori
- Department of Sciences and Technologies, University of Naples “Parthenope”, Business District, Block C4, 80143 Naples, Italy;
| | - Marco Guida
- Department of Biology, University of Naples “Federico II”, Via Cinthia, 80126 Naples, Italy; (R.G.); (A.M.); (M.G.); (E.G.)
| | - Roberto Nigro
- Department of Chemical, Material and Production Engineering, University of Naples “Federico II”, Piazzale V. Tecchio 80, 80125 Naples, Italy;
| | - Emilia Galdiero
- Department of Biology, University of Naples “Federico II”, Via Cinthia, 80126 Naples, Italy; (R.G.); (A.M.); (M.G.); (E.G.)
| |
Collapse
|
13
|
Moreddu R, Vigolo D, Yetisen AK. Contact Lens Technology: From Fundamentals to Applications. Adv Healthc Mater 2019; 8:e1900368. [PMID: 31183972 DOI: 10.1002/adhm.201900368] [Citation(s) in RCA: 115] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 05/20/2019] [Indexed: 12/29/2022]
Abstract
Contact lenses are ocular prosthetic devices used by over 150 million people worldwide. Primary applications of contact lenses include vision correction, therapeutics, and cosmetics. Contact lens materials have significantly evolved over time to minimize adverse effects associated with contact lens wearing, to maintain a regular corneal metabolism, and to preserve tear film stability. This article encompasses contact lens technology, including materials, chemical and physical properties, manufacturing processes, microbial contamination, and ocular complications. The function and the composition of the tear fluid are discussed to assess its potential as a diagnostic media. The regulatory standards of contact lens devices with regard to biocompatibility and contact lens market are presented. Future prospects in contact lens technology are evaluated, with particular interest given to theranostic applications for in situ continuous monitoring the ocular physiology.
Collapse
Affiliation(s)
- Rosalia Moreddu
- Department of Chemical EngineeringImperial College London SW7 2AZ London UK
- School of Chemical EngineeringUniversity of Birmingham B15 2TT Birmingham UK
| | - Daniele Vigolo
- School of Chemical EngineeringUniversity of Birmingham B15 2TT Birmingham UK
| | - Ali K. Yetisen
- Department of Chemical EngineeringImperial College London SW7 2AZ London UK
| |
Collapse
|
14
|
Biocidal Efficacy of a Hydrogen Peroxide Lens Care Solution Incorporating a Novel Wetting Agent. Eye Contact Lens 2019; 45:164-170. [PMID: 30138250 DOI: 10.1097/icl.0000000000000549] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the antimicrobial effects of CLEAR CARE, a 3% hydrogen peroxide (H2O2) solution formulated for simultaneous cleaning, daily protein removal, disinfection, and storage of soft (hydrophilic) hydrogel, silicone hydrogel, and gas-permeable contact lenses, and CLEAR CARE PLUS, consisting of the 3% H2O2 solution plus a novel wetting agent, polyoxyethylene-polyoxybutylene (EOBO-21). METHODS Three lots each of the 2 solutions were incubated with 5 compendial microorganisms required by the Food and Drug Administration (FDA) 510(k) and International Organization for Standardization (ISO) 14729 stand-alone procedures, 4 clinical isolates of Gram-positive and Gram-negative bacteria, and trophozoites and cysts of 2 Acanthamoeba strains that are associated with microbial keratitis. Microbial loads were evaluated after disinfection and neutralization. RESULTS Both solutions exceeded the FDA/ISO stand-alone primary criteria against Gram-positive and Gram-negative compendial bacteria, yeast, and mold after only 1.5-hr disinfection/neutralization. At the recommended minimum disinfection time, bacteria were reduced by 4.4 to 5.1 logs, yeast by 4.4 to 4.9 logs, and mold by 2.9 to 3.5 logs with and without organic soil. In addition, both solutions eliminated or effectively reduced populations of clinically relevant ocular bacterial isolates (4.5-5.0 logs), Acanthamoeba trophozoites (3.4-4.2 logs), and cysts (1.5-2.1 logs). CONCLUSION Both solutions eliminated or reduced populations of FDA/ISO compendial bacteria and fungi as well as clinically relevant microorganisms and Acanthamoeba trophozoites and cysts. The addition of EOBO-21 to the 3% H2O2 lens care solution had no impact on antimicrobial activity.
Collapse
|
15
|
|
16
|
Study of Disinfectant Resistance Genes in Ocular Isolates of Pseudomonas aeruginosa. Antibiotics (Basel) 2018; 7:antibiotics7040088. [PMID: 30326554 PMCID: PMC6315377 DOI: 10.3390/antibiotics7040088] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 10/11/2018] [Accepted: 10/11/2018] [Indexed: 11/17/2022] Open
Abstract
Background: The prevalence of disinfectant resistance in Pseudomonas aeruginosa is on the rise. P. aeruginosa is the most common bacteria isolated from cases of microbial keratitis. Many multi-purpose contact lens disinfectant solutions are available to decontaminate contact lenses before use and to help reduce the incidence of infections. However, with increasing disinfectant resistance, the effect of multi-purpose disinfectant solutions may diminish. The goal of this study was to examine genes associated with disinfectant resistance in ocular isolates of P. aeruginosa and understand the strain’s susceptibility to different multipurpose disinfectant solutions. Methods: Seven potential disinfectant resistance genes were used in BLASTn searches against the whole genomes of 13 eye isolates of P. aeruginosa. A microdilution broth method was used to examine susceptibility to four different multipurpose disinfectant solutions. Results: All strains possessed the sugE2, sugE3 and emrE (qacE) genes. The sugE1 and qacEdelta1 genes were present in 6/13 isolates. No strains contained the qacF or qacG genes. All tested disinfectant solutions had the ability to kill all test strains at 100% concentration, with some strains being susceptible at 1:8 dilutions of the disinfecting solutions. However, the presence of disinfectant resistance genes was not associated with susceptibility to multi-purpose disinfectants. Conclusion: All four tested contact lens disinfectant preparations are effective against P. aeruginosa isolates regardless of the presence of disinfectant resistance genes.
Collapse
|
17
|
Laxmi Narayana B, Rao P, Bhat S, Vidyalakshmi K. Comparison of the Antimicrobial Efficacy of Various Contact Lens Solutions to Inhibit the Growth of Pseudomonas aeruginosa and Staphylococcus aureus. Int J Microbiol 2018; 2018:5916712. [PMID: 29955230 PMCID: PMC6000856 DOI: 10.1155/2018/5916712] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 05/06/2018] [Indexed: 11/18/2022] Open
Abstract
Soft contact lenses provide perfect conditions for the breeding of pathogens. The study is a prospective, experimental study, conducted to know the antimicrobial ability of multipurpose contact lens solution against standard strains of Staphylococcus aureus and Pseudomonas aeruginosa by the stand-alone test. The test method is based on the procedures in the ISO 14729 standard primary stand-alone test. Three multipurpose contact lens care solutions commercially available in Mangalore markets, namely, Biotrue (Bausch & Lomb), Opti-Free Replenish (Alcon), and Aquasoft (Stericon Pharma), were tested for its antimicrobial effect in the microbiology lab at Kasturba Medical College, Mangalore. According to this study, the solutions named "Biotrue" and "Aquasoft" met the primary stand-alone and reached the 3log reduction and 5log reduction criteria in the manufacturer recommended time, respectively. No conclusion could be drawn for Opti-Free Replenish since the minimum recommended disinfection time was overnight, whereas it was noted for 6 hr only, and it should have been experimented further. The effectiveness of multipurpose solutions varies against different bacterial species. We have observed that the antimicrobial activity of different solutions varies with respect to time of incubation, and also there was a marked difference in the activity of some solutions against S. aureus and P. aeruginosa. So, it is necessary for the contact lens users to store their lenses in solutions for longer duration of hours. It is also recommended to use solutions that clear the ISO 14729 standards for better health conditions of the eye.
Collapse
Affiliation(s)
- B. Laxmi Narayana
- Department of Microbiology, Kasturba Medical College, Manipal Academy Higher Education, Mangalore, Karnataka 575001, India
| | - Pooja Rao
- Department of Microbiology, Kasturba Medical College, Manipal Academy Higher Education, Mangalore, Karnataka 575001, India
| | - Sevitha Bhat
- Department of Microbiology, Kasturba Medical College, Manipal Academy Higher Education, Mangalore, Karnataka 575001, India
| | - K. Vidyalakshmi
- Department of Microbiology, Kasturba Medical College, Manipal Academy Higher Education, Mangalore, Karnataka 575001, India
| |
Collapse
|
18
|
Pfaender S, Helfritz FA, Siddharta A, Todt D, Behrendt P, Heyden J, Riebesehl N, Willmann W, Steinmann J, Münch J, Ciesek S, Steinmann E. Environmental Stability and Infectivity of Hepatitis C Virus (HCV) in Different Human Body Fluids. Front Microbiol 2018; 9:504. [PMID: 29636728 PMCID: PMC5881408 DOI: 10.3389/fmicb.2018.00504] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Accepted: 03/05/2018] [Indexed: 12/11/2022] Open
Abstract
Background: Hepatitis C virus (HCV) is a hepatotropic, blood-borne virus, but in up to one-third of infections of the transmission route remained unidentified. Viral genome copies of HCV have been identified in several body fluids, however, non-parental transmission upon exposure to contaminated body fluids seems to be rare. Several body fluids, e.g., tears and saliva, are renowned for their antimicrobial and antiviral properties, nevertheless, HCV stability has never been systematically analyzed in those fluids. Methods: We used state of the art infectious HCV cell culture techniques to investigate the stability of HCV in different body fluids to estimate the potential risk of transmission via patient body fluid material. In addition, we mimicked a potential contamination of HCV in tear fluid and analyzed which impact commercially available contact lens solutions might have in such a scenario. Results: We could demonstrate that HCV remains infectious over several days in body fluids like tears, saliva, semen, and cerebrospinal fluid. Only hydrogen-peroxide contact lens solutions were able to efficiently inactivate HCV in a suspension test. Conclusion: These results indicate that HCV, once it is present in various body fluids of infected patients, remains infective and could potentially contribute to transmission upon direct contact.
Collapse
Affiliation(s)
- Stephanie Pfaender
- Institute of Virology and Immunology, Mittelhäusern, Switzerland.,Department of Infectious Diseases and Pathobiology, Vetsuisse Faculty, University of Bern, Bern, Switzerland
| | - Fabian A Helfritz
- Department of General, Visceral and Transplantation Surgery, University Hospital of Essen, University of Duisburg-Essen, Essen, Germany
| | - Anindya Siddharta
- Institute of Experimental Virology, TWINCORE-Centre for Experimental and Clinical Infections Research, a joint venture between the Hannover Medical School and the Helmholtz Centre for Infection Research, Hanover, Germany
| | - Daniel Todt
- Institute of Experimental Virology, TWINCORE-Centre for Experimental and Clinical Infections Research, a joint venture between the Hannover Medical School and the Helmholtz Centre for Infection Research, Hanover, Germany.,Department of Molecular and Medical Virology, Ruhr-University Bochum, Bochum, Germany
| | - Patrick Behrendt
- Institute of Experimental Virology, TWINCORE-Centre for Experimental and Clinical Infections Research, a joint venture between the Hannover Medical School and the Helmholtz Centre for Infection Research, Hanover, Germany.,Department of Gastroenterology, Hepatology and Endocrinology, Hannover Medical School, Hanover, Germany
| | - Julia Heyden
- Institute of Experimental Virology, TWINCORE-Centre for Experimental and Clinical Infections Research, a joint venture between the Hannover Medical School and the Helmholtz Centre for Infection Research, Hanover, Germany
| | - Nina Riebesehl
- Institute of Experimental Virology, TWINCORE-Centre for Experimental and Clinical Infections Research, a joint venture between the Hannover Medical School and the Helmholtz Centre for Infection Research, Hanover, Germany
| | - Wiebke Willmann
- Institute of Experimental Virology, TWINCORE-Centre for Experimental and Clinical Infections Research, a joint venture between the Hannover Medical School and the Helmholtz Centre for Infection Research, Hanover, Germany
| | - Joerg Steinmann
- Institute of Medical Microbiology, University Hospital of Essen, University of Duisburg-Essen, Essen, Germany.,Institute for Clinical Hygiene, Medical Microbiology and Clinical Infectiology, Paracelsus Medical Private University, Nürnberg Hospital, Nürnberg, Germany
| | - Jan Münch
- Institute of Molecular Virology, Ulm University Medical Center, Ulm, Germany
| | - Sandra Ciesek
- Institute for Virology, University Hospital of Essen, University of Duisburg-Essen, Essen, Germany
| | - Eike Steinmann
- Institute of Experimental Virology, TWINCORE-Centre for Experimental and Clinical Infections Research, a joint venture between the Hannover Medical School and the Helmholtz Centre for Infection Research, Hanover, Germany.,Department of Molecular and Medical Virology, Ruhr-University Bochum, Bochum, Germany
| |
Collapse
|
19
|
El-Ganiny AM, Shaker GH, Aboelazm AA, El-Dash HA. Prevention of Bacterial Biofilm Formation on Soft Contact Lenses Using Natural Compounds. J Ophthalmic Inflamm Infect 2017; 7:11. [PMID: 28421562 PMCID: PMC5395510 DOI: 10.1186/s12348-017-0129-0] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2016] [Accepted: 03/31/2017] [Indexed: 01/24/2023] Open
Abstract
Purpose In eye care field, contact lenses (CL) have a great impact on improving vision, but their use can be limited by ocular infection. CL- associated infections can be reduced by good attention to CL storage case practice. CL-care solutions should be able to control microbial growth on CL. The aim of the study was to evaluate and compare the efficacy of CL-care solutions (found in Egyptian market) with some natural compounds in removal and inhibition of bacterial biofilm formed on soft CL. Clinical isolates were recovered from patients having conjunctivitis from Benha University Hospital and identified microbiologically. Quantification of biofilm was done using microtiter plate assay. Three multipurpose CL-care solutions were examined for their ability to remove and inhibit biofilm. Also four natural extracts having antibacterial activity and are safe on eye were tested for their anti-biofilm activity. Results The major bacterial isolates from eye infections were Pseudomonas aeruginosa (36%) and Staphylococcus spp. (37.8%). Only 33.3% of isolates showed ability to produce weak to moderate biofilm. The tested multi-purpose CL-care solutions showed moderate ability to remove preformed biofilm. Among the tested natural compounds, Calendula officinalis and Buddleja salviifolia extracts showed an excellent efficacy in inhibition of biofilm and also removal of preformed biofilm. Conclusion This study demonstrated that isolates from infected eye and CL-cases showed weak to moderate biofilm formation. Calendula officinalis and Buddleja salviifolia extracts showed excellent effect on inhibition and removal of biofilm, these extracts could be added into CL-care solutions which could markedly reduce eye-infections during CL-wear.
Collapse
Affiliation(s)
- Amira M El-Ganiny
- Microbiology and Immunology Department, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt.
| | - Ghada H Shaker
- Microbiology and Immunology Department, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt
| | - Abeer A Aboelazm
- Microbiology and Immunology Department, Faculty of Medicine, Benha University, Benha, Egypt
| | - Heba A El-Dash
- Microbiology and Immunology Department, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt
| |
Collapse
|
20
|
Component Analysis of Multipurpose Contact Lens Solutions To Enhance Activity against Pseudomonas aeruginosa and Staphylococcus aureus. Antimicrob Agents Chemother 2016; 60:4259-63. [PMID: 27139484 DOI: 10.1128/aac.00644-16] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Accepted: 04/28/2016] [Indexed: 11/20/2022] Open
Abstract
More than 125 million people wear contact lenses worldwide, and contact lens use is the single greatest risk factor for developing microbial keratitis. We tested the antibacterial activity of multipurpose contact lens solutions and their individual component preservatives against the two most common pathogens causing bacterial keratitis, Pseudomonas aeruginosa and Staphylococcus aureus The in vitro antibacterial activity of five multipurpose contact lens solutions (Opti-Free GP, Boston Simplus, Boston Advance, Menicare GP, and Lobob) was assayed by the standard broth dilution method. Synergy between the preservative components found in the top performing solutions was assayed using checkerboard and time-kill assays. The ISO 14729 criteria and the standard broth dilution method were used to define an optimized contact lens solution formulation against a clinical panel of drug-susceptible and drug-resistant P. aeruginosa and S. aureus strains. Preservatives with the biguanide function group, chlorhexidine and polyaminopropylbiguanide (PAPB), had the best antistaphylococcal activity, while EDTA was the best antipseudomonal preservative. The combination of chlorhexidine and EDTA had excellent synergy against P. aeruginosa A solution formulation containing chlorhexidine (30 ppm), PAPB (5 ppm), and EDTA (5,000 ppm) had three to seven times more antipseudomonal activity than anything available to consumers today. A multipurpose contact lens solution containing a combination of chlorhexidine, PAPB, and EDTA could help to reduce the incidence of microbial keratitis for contact lens users worldwide.
Collapse
|
21
|
Special Commentary: Food and Drug Administration, American Academy of Ophthalmology, American Academy of Optometry, American Optometric Association and the Contact Lens Association of Ophthalmologists Cosponsored Workshop: Revamping Microbiological Test Methods for Contact Lenses, Products, and Accessories to Protect Health and Ensure Safety. Eye Contact Lens 2016; 41:329-33. [PMID: 26469524 DOI: 10.1097/icl.0000000000000205] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
Infektionsschutz und spezielle Hygienemaßnahmen in klinischen Disziplinen. KRANKENHAUS- UND PRAXISHYGIENE 2016. [PMCID: PMC7152143 DOI: 10.1016/b978-3-437-22312-9.00005-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
Fungal isolation from disinfectant solutions of contact lens storage cases among asymptomatic users. Eye Contact Lens 2014; 41:87-90. [PMID: 25503912 DOI: 10.1097/icl.0000000000000069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To investigate the incidence of fungal contamination of store disinfectant solutions contained in contact lens storage cases belonging to asymptomatic contact lens users. METHODS Asymptomatic contact lens users were asked to bring their storage cases, lenses included, without having opened the lid of the cup after placing lenses inside. The following information was recorded: age, sex, type of refractive error, contact lens material, schedule of wear, and brand of disinfectant solution. Included subjects had to comply with lens handling, cleaning, and replacement instructions given by the manufacturer or their attending optometrist. One sample per cup of contact lens case was collected using a sterile syringe. Samples were cultured on proper media for 96 hr at 35°C. Fungi were identified to species level by standard methodology. RESULTS A total of 216 samples were collected from 117 contact lens storage cases. All participants were using monthly disposable hydrogel lenses on a daily wear basis. Seven fungal species were isolated from 15 specimens (6.9%) collected from 12 storage cases (10.2%). These included one Fusarium solani, four Aspergillus niger, two Aspergillus fumigatus, five Candida parapsilosis, one Candida tropicalis, one Rhodotorula rubra, and one F. solani in combination with Candida guilliermondii. Disinfectant solutions containing hydrogen peroxide were found to be less effective than various alternative solutions in eliminating fungal species. CONCLUSIONS The results of this study show that even when contact lens users report compliance for handling, cleaning, and replacement according to the manufacturer's instructions, the potential risk of contact lens-related fungal keratitis still remains.
Collapse
|
24
|
Schafer J, Steffen R, Rah MJ. Patient satisfaction with a novel one-step hydrogen peroxide solution. Clin Ophthalmol 2014; 8:2035-40. [PMID: 25336902 PMCID: PMC4199818 DOI: 10.2147/opth.s69701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
PURPOSE We aimed to evaluate the product performance of a novel one-step hydrogen peroxide cleaning and disinfecting solution, PeroxiClear ("Test" solution), when used by habitual Clear Care users to bilaterally clean and disinfect their soft contact lenses, for approximately 2 weeks. METHODS This was a 2-week, open-label, bilateral eye study designed to include subjects ranging in age from 18 to 55 years, inclusive. All subjects were habitual users of the Clear Care peroxide regimen for cleaning, disinfecting, and storage of their soft contact lenses, for at least 6 months prior to enrolling in the study. Subjects were examined at two study visits: a screening/dispensing visit and a 2-week follow-up visit. The primary end point, patient preference for the Test solution, was evaluated with an online survey administered after 7 days of using the Test cleaning and disinfecting solution. Respondents could answer questions with neutral or nonneutral responses (better or worse). Statistical analyses were conducted to compare differences for nonneutral responses. RESULTS Of the 299 eligible subjects enrolled, 297 completed the study, conducted at 21 sites by 21 investigators in the United States. A significantly higher proportion of nonneutral respondents reported the Test solution was better overall (85.9%) than their habitual contact lens solution (14.1%) (P<0.001). The proportion of subjects who preferred the Test solution over their habitual solution was significantly higher for each of the preference questions regarding comfort (85.4% vs 14.6%), moistness (90.0% vs 10.0%), cleanness (91.6% vs 8.4%), and clarity of vision (85.8% vs 14.2%). CONCLUSION After 7 days of using the Test cleaning and disinfecting solution, survey results indicated high levels of patient satisfaction and preference over the habitual solution, particularly in the areas of comfort, moisture, and cleanness.
Collapse
|
25
|
|
26
|
Müller G, Koburger T, Kramer A. Interaction of polyhexamethylene biguanide hydrochloride (PHMB) with phosphatidylcholine containing o/w emulsion and consequences for microbicidal efficacy and cytotoxicity. Chem Biol Interact 2013; 201:58-64. [PMID: 23313712 DOI: 10.1016/j.cbi.2013.01.001] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2012] [Revised: 12/05/2012] [Accepted: 01/02/2013] [Indexed: 11/27/2022]
Abstract
Oil-in-water (o/w) emulsions containing egg yolk phosphatidylcholine (EPC) were combined with aqueous polyhexamethylene biguanide hydrochloride (PHMB). The PHMB concentration in the aqueous phase was estimated by filtration centrifugation experiments. In parallel, PHMB concentration was assessed utilizing cytotoxicity assays (neutral red) on cultured murine fibroblasts (L929 cells) and tests of bactericidal efficacy on either Pseudomonas aeruginosa or Staphylococcus aureus. Biological tests were performed in cell culture medium. Filtration centrifugation experiments demonstrated much higher aqueous PHMB concentrations than did the assays for biologically effective PHMB. Therefore, biological test systems should preferably be used to verify effective PHMB concentrations. Tests of microbicidal efficacy in which the same 0.05% PHMB o/w emulsion was re-used 8 times revealed a drug delivery system activated by the presence of test bacteria.
Collapse
Affiliation(s)
- Gerald Müller
- Institute of Hygiene and Environmental Medicine, Ernst-Moritz-Arndt-University Greifswald, W.-Rathenau-Str. 49a, 17487 Greifswald, Germany
| | | | | |
Collapse
|