2
|
Gonçalves AC, Marson FAL, Mendonça RMH, Bertuzzo CS, Paschoal IA, Ribeiro JD, Ribeiro AF, Levy CE. Chloride and sodium ion concentrations in saliva and sweat as a method to diagnose cystic fibrosis. J Pediatr (Rio J) 2019; 95:443-450. [PMID: 29782810 DOI: 10.1016/j.jped.2018.04.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 04/14/2018] [Accepted: 04/16/2018] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVE Cystic fibrosis diagnosis is dependent on the chloride ion concentration in the sweat test (≥60mEq/mL - recognized as the gold standard indicator for cystic fibrosis diagnosis). Moreover, the salivary glands express the CFTR protein in the same manner as sweat glands. Given this context, the objective was to verify the correlation of saliva chloride concentration and sweat chloride concentration, and between saliva sodium concentration and sweat sodium concentration, in patients with cystic fibrosis and healthy control subjects, as a tool for cystic fibrosis diagnosis. METHODS There were 160 subjects enrolled: 57/160 (35.70%) patients with cystic fibrosis and two known CFTR mutations and 103/160 (64.40%) healthy controls subjects. Saliva ion concentration was analyzed by ABL 835 Radiometer® equipment and, sweat chloride concentration and sweat sodium concentration, respectively, by manual titration using the mercurimetric procedure of Schales & Schales and flame photometry. Statistical analysis was performed by the chi-squared test, the Mann-Whitney test, and Spearman's correlation. Alpha=0.05. RESULTS Patients with cystic fibrosis showed higher values of sweat chloride concentration, sweat sodium concentration, saliva chloride concentration, and saliva sodium concentration than healthy controls subjects (p-value<0.001). The correlation between saliva chloride concentration and sweat chloride concentration showed a positive Spearman's Rho (correlation coefficient)=0.475 (95% CI=0.346 to 0.587). Also, the correlation between saliva sodium concentration and sweat sodium concentration showed a positive Spearman's Rho=0.306 (95% CI=0.158 to 0.440). CONCLUSIONS Saliva chloride concentration and saliva sodium concentration are candidates to be used in cystic fibrosis diagnosis, mainly in cases where it is difficult to achieve the correct sweat amount, and/or CFTR mutation screening is difficult, and/or reference methods for sweat test are unavailable to implement or are not easily accessible by the general population.
Collapse
Affiliation(s)
- Aline Cristina Gonçalves
- Universidade Estadual de Campinas (Unicamp), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, Brasil
| | - Fernando Augusto Lima Marson
- Universidade Estadual de Campinas (Unicamp), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, Brasil; Universidade Estadual de Campinas (Unicamp), Faculdade de Ciências Médicas, Departamento de Genética Médica, Campinas, SP, Brasil.
| | | | - Carmen Sílvia Bertuzzo
- Universidade Estadual de Campinas (Unicamp), Faculdade de Ciências Médicas, Departamento de Genética Médica, Campinas, SP, Brasil
| | - Ilma Aparecida Paschoal
- Universidade Estadual de Campinas (Unicamp), Faculdade de Ciências Médicas, Departamento de Medicina Interna, Campinas, SP, Brasil
| | - José Dirceu Ribeiro
- Universidade Estadual de Campinas (Unicamp), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, Brasil
| | - Antônio Fernando Ribeiro
- Universidade Estadual de Campinas (Unicamp), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, Brasil
| | - Carlos Emílio Levy
- Universidade Estadual de Campinas (Unicamp), Faculdade de Ciências Médicas, Departamento de Patologia Clínica, Campinas, SP, Brasil.
| |
Collapse
|
4
|
Gomez CCS, Marson FAL, Servidoni MF, Ribeiro AF, Ribeiro MÂGO, Gama VAL, Costa ET, Ribeiro JD, Vieira Junior FU. Evaluation of continuous constant current and continuous pulsed current in sweat induction for cystic fibrosis diagnosis. BMC Pulm Med 2018; 18:153. [PMID: 30217179 PMCID: PMC6137935 DOI: 10.1186/s12890-018-0696-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 07/24/2018] [Indexed: 11/17/2022] Open
Abstract
Background The sweat test (ST) is the gold standard for the diagnosis of cystic fibrosis (CF). However, little is known about sweat induction using different types of currents and waves. In this context, our objective was to develop a device to induce sweat and compare the use of continuous constant current (CCC) and continuous pulsed current (CPC) in individuals with CF and healthy controls. Methods A prospective cross-sectional study with experimental intervention. The variables of gender, ethnicity, age, and body mass index (BMI) were considered. The method of Gibson and Cooke was used, and the following markers were evaluated: sweat weight, electrical impedance, sufficient sweat amount, and CF diagnosis. Triangular (TPC) or sinusoidal (SPC) pulsed current was applied to the right arm, and CCC was applied to the left arm. Results The study analyzed 260 individuals, 141/213 (54.2%) were female participants, 135/260 (51.9%) were Caucasians. The distribution of individuals by concentration of chloride at the ST was: (CF) 26/260 (10%); (borderlines) 109/260 (41.9%); (healthy) 97/260 (37.3%); (insufficient weight in sweat) 28/260 (10.8%). No association was observed between the sufficient sweat amount to perform the ST when we compared the currents. However, the SPC showed a higher amount of sweat weight. Using Bland and Altman plot considering the agreement between the sweat chloride values achieved from CPC [SPC and TPC] and CCC, there was no proportional bias and mean values are unrelated and only explain less than 8% of the variation. Moreover, TPC presented higher electrical impedance when compared with SPC and CCC. SPC presented lower electrical impedance and higher sweat weight than CCC. Male participants presented lower electrical impedance and higher sweat weight with CCC and TPC, and higher sweat weight with SPC. Conclusions The evaluated currents are safe and able to induce and produce sweat in sufficient quantities for the ST. SPC presented lower electrical impedance when compared with other currents. The use of SPC is recommended to induce sweat in patients with sweat problems. Finally, ethnicity, gender, age and BMI did not influence sweat induction at the ST, and no side effect was observed in our study. Electronic supplementary material The online version of this article (10.1186/s12890-018-0696-3) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Carla Cristina Souza Gomez
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil. .,Center for Research in Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil.
| | - Fernando Augusto Lima Marson
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil. .,Center for Research in Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil. .,Department of Medical Genetics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil.
| | - Maria Fátima Servidoni
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil.,Center for Research in Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil.,Gastrocentro - Endoscopy Unit, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-872, Brazil
| | - Antônio Fernando Ribeiro
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil.,Center for Research in Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil
| | - Maria Ângela Gonçalves Oliveira Ribeiro
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil.,Center for Research in Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil
| | - Veruska Acioli Lopes Gama
- Center for Biomedical Engineering, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-970, Brazil.,Department of Biomedical Engineering, Faculty of Electrical and Computer Engineering, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-881, Brazil.,Federal Institute of Education, Science and Technology of Sao Paulo, Campus Campinas, km 143.5, Campinas, São Paulo, 13069-901, Brazil
| | - Eduardo Tavares Costa
- Center for Biomedical Engineering, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-970, Brazil.,Department of Biomedical Engineering, Faculty of Electrical and Computer Engineering, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-881, Brazil
| | - José Dirceu Ribeiro
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil.,Center for Research in Pediatrics, School of Medical Sciences, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-887, Brazil
| | - Francisco Ubaldo Vieira Junior
- Center for Biomedical Engineering, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-970, Brazil.,Department of Biomedical Engineering, Faculty of Electrical and Computer Engineering, University of Campinas, Cidade Universitária Zeferino Vaz, Barão Geraldo, Campinas, São Paulo, 13083-881, Brazil.,Federal Institute of Education, Science and Technology of Sao Paulo, Campus Campinas, km 143.5, Campinas, São Paulo, 13069-901, Brazil
| |
Collapse
|
5
|
Hussain JN, Mantri N, Cohen MM. Working Up a Good Sweat - The Challenges of Standardising Sweat Collection for Metabolomics Analysis. Clin Biochem Rev 2017; 38:13-34. [PMID: 28798503 PMCID: PMC5548369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
INTRODUCTION Human sweat is a complex biofluid of interest to diverse scientific fields. Metabolomics analysis of sweat promises to improve screening, diagnosis and self-monitoring of numerous conditions through new applications and greater personalisation of medical interventions. Before these applications can be fully developed, existing methods for the collection, handling, processing and storage of human sweat need to be revised. This review presents a cross-disciplinary overview of the origins, composition, physical characteristics and functional roles of human sweat, and explores the factors involved in standardising sweat collection for metabolomics analysis. METHODS A literature review of human sweat analysis over the past 10 years (2006-2016) was performed to identify studies with metabolomics or similarly applicable 'omics' analysis. These studies were reviewed with attention to sweat induction and sampling techniques, timing of sweat collection, sweat storage conditions, laboratory derivation, processing and analytical platforms. RESULTS Comparative analysis of 20 studies revealed numerous factors that can significantly impact the validity, reliability and reproducibility of sweat analysis including: anatomical site of sweat sampling, skin integrity and preparation; temperature and humidity at the sweat collection sites; timing and nature of sweat collection; metabolic quenching; transport and storage; qualitative and quantitative measurements of the skin microbiota at sweat collection sites; and individual variables such as diet, emotional state, metabolic conditions, pharmaceutical, recreational drug and supplement use. CONCLUSION Further development of standard operating protocols for human sweat collection can open the way for sweat metabolomics to significantly add to our understanding of human physiology in health and disease.
Collapse
Affiliation(s)
- Joy N Hussain
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Vic. 3083
| | - Nitin Mantri
- Health Innovations Research Institute, School of Applied Sciences, RMIT University, Bundoora, Vic. 3083, Australia
| | - Marc M Cohen
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Vic. 3083
| |
Collapse
|
6
|
Faria AG, Marson FAL, Gomez CCS, Servidoni MDF, Ribeiro AF, Ribeiro JD. Thirty Years of Sweat Chloride Testing at One Referral Center. Front Pediatr 2017; 5:222. [PMID: 29124052 PMCID: PMC5662556 DOI: 10.3389/fped.2017.00222] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 10/03/2017] [Indexed: 01/21/2023] Open
Abstract
OBJECTIVE To conduct a descriptive analysis of the sweat test (ST), associating ST results with epidemiological data, CFTR (cystic fibrosis transmembrane conductance regulator) mutations and reasons to indicate the ST, as well as correlating sweat sodium and sweat chloride concentrations in subjects. METHODS Retrospective survey and descriptive analysis of 5,721 ST at a university referral center. RESULTS The inclusion of the subjects was based on clinical data related with cystic fibrosis (CF) phenotype. The samples were grouped by (i) sweat chloride concentrations (mEq/L): <30: 3,249/5,277 (61.6%); ≥30 to <60: 1,326/5,277 (25.1%); ≥60: 702/5,277 (13.3%) and (ii) age: (Group A--GA) 0 to <6 months; (Group B--GB) ≥6 months to <18 years; (Group C--GC) ≥18 years. Digestive symptoms showed higher prevalence ratio for the CF diagnosis as well as association between younger age and higher values of sweat chloride, sweat sodium, and chloride/sodium ratio. The indication of ST due to respiratory symptoms was higher in GB and associated with greater age, lower values of sweat chloride, sweat sodium, and chloride/sodium ratio. There was higher prevalence of ST with sweat chloride levels <30 mEq/L in GB, ≥60 mEq/L in GC, and with borderline level in GB. There was positive correlation between sweat sodium and sweat chloride. Sweat chloride/sweat sodium and sweat sodium-sweat chloride indexes showed association with sex, reason for ST indication, and CFTR mutations. Sex alters some values presented in the ST. The number of ST/year performed before and after the newborn screening implementation was the same; however, we observed a higher number of borderlines values. A wide spectrum of CFTR mutation was found. Severe CFTR mutations and F508del/F508del genotype were associated with highest probability of ST chloride levels ≥60 mEq/L, and the absence of CFTR mutations identified was associated with borderline ST and respiratory symptoms. CONCLUSIONS ST data showed wide variability dependent on age, sex, reason for examination indication, CFTR mutations, and weight of the collected sweat sample. Sweat sodium concentration is directly correlated with sweat chloride levels and it could be used as a quality parameter.
Collapse
Affiliation(s)
- Alethéa Guimarães Faria
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Campinas, Brazil.,Laboratory of Pulmonary Physiology, Center for Pediatrics Investigation, School of Medical Sciences, University of Campinas, Campinas, Brazil
| | - Fernando Augusto Lima Marson
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Campinas, Brazil.,Laboratory of Pulmonary Physiology, Center for Pediatrics Investigation, School of Medical Sciences, University of Campinas, Campinas, Brazil.,Department of Medical Genetics, School of Medical Sciences, University of Campinas, Campinas, Brazil
| | | | - Maria de Fátima Servidoni
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Campinas, Brazil.,Laboratory of Pulmonary Physiology, Center for Pediatrics Investigation, School of Medical Sciences, University of Campinas, Campinas, Brazil
| | | | - José Dirceu Ribeiro
- Department of Pediatrics, School of Medical Sciences, University of Campinas, Campinas, Brazil.,Laboratory of Pulmonary Physiology, Center for Pediatrics Investigation, School of Medical Sciences, University of Campinas, Campinas, Brazil
| |
Collapse
|