1
|
Wu PK, Chang WS, Chen KT, Huang PC, Ho CH, Chien CS, Wu TM. Does the utilization of fluoroscopy affect the accuracy of prosthesis position in patients undergoing hip replacement surgery via the direct anterior approach compared to the posterolateral approach for an experienced surgeon? A single-center retrospective study. BMC Musculoskelet Disord 2024; 25:816. [PMID: 39407225 PMCID: PMC11476075 DOI: 10.1186/s12891-024-07917-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Accepted: 10/03/2024] [Indexed: 10/20/2024] Open
Abstract
BACKGROUND The direct anterior approach (DAA) for total hip arthroplasty (THA) has gained popularity due to perceived advantages in achieving better early outcomes. However, the theoretical benefits such as precise implant positioning and accurate leg length restoration are still inconsistent. In this study, we compared implant position and leg length discrepancy (LLD) of the DAA and posterolateral approach (PLA) conducted by a single surgeon who had mastered both approaches. METHODS This study retrospectively reviewed the medical records and radiographic images of 244 patients who underwent THA between 2012 and 2021 by a single experienced surgeon using either the DAA (n = 120) or PLA (n = 124). Postoperative pelvic anteroposterior radiographs at 6 months follow-up were used to assess acetabular component inclination and anteversion, as well as LLD. Mann-Whitney U tests and Chi-squared test were performed to compare outcomes between the two approaches. RESULTS No significant differences were observed in patient demographics between the two groups. The DAA group demonstrated significantly lower postoperative LLD (0.00 mm) compared to the PLA group (5.00 mm, p < 0.0001). No significant difference was observed in the Lewinnek zone for cup anteversion and inclination angles between the two groups. CONCLUSIONS For experienced surgeons in other approaches, our findings suggest transferring to the DAA may not substantially improve cup positioning, but it might slightly enhance limb length measurement. For surgeons already proficient in other approaches and deciding to maintain those approaches, their primary concern for optimal THA outcome should be striving for leg length equivalence.
Collapse
Affiliation(s)
- Po-Kuan Wu
- Department of Orthopedic Surgery, Chi-Mei Medical Center, No. 901., ChungHua Road, YongHang District, Tainan, Taiwan
| | - Wen-Shuo Chang
- Department of Orthopedic Surgery, Chi-Mei Medical Center, No. 901., ChungHua Road, YongHang District, Tainan, Taiwan
| | - Kuan-Ting Chen
- Department of Orthopedic Surgery, Chi-Mei Medical Center, No. 901., ChungHua Road, YongHang District, Tainan, Taiwan
| | - Po-Chang Huang
- Department of Orthopedic Surgery, Chi-Mei Medical Center, No. 901., ChungHua Road, YongHang District, Tainan, Taiwan
| | - Chung-Han Ho
- Department of Medical Research, Chi-Mei Medical Center, Tainan, Taiwan
| | - Chi-Sheng Chien
- Department of Orthopedic Surgery, Chi-Mei Medical Center, No. 901., ChungHua Road, YongHang District, Tainan, Taiwan
| | - Tsung-Mu Wu
- Department of Orthopedic Surgery, Chi-Mei Medical Center, No. 901., ChungHua Road, YongHang District, Tainan, Taiwan.
| |
Collapse
|
2
|
Noor EA, Dilogo IH, Silitonga J, Ramadhani R. Analysis on association between sagittal stem alignment and early functional and radiological outcome following primary cementless total hip replacement. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:2129-2136. [PMID: 38557890 DOI: 10.1007/s00590-024-03904-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 03/07/2024] [Indexed: 04/04/2024]
Abstract
INTRODUCTION Accurate reconstruction of hip anatomy and biomechanics is mandatory for achieving good clinical outcomes following total hip replacement (THR). Optimal stem alignment is essential to avoid impingement or loosening. This study aimed to evaluate sagittal stem position following cementless THR and its relationship with patient's functional outcome and post-operative radiological parameters. METHOD We performed analytical observational study with cross-sectional design on 71 hips (67 patients, ranged 18-85 years old) that underwent primary cementless THR in two orthopedic centers in Jakarta, Indonesia. All hips were operated through either anterolateral or posterior approach using either extended/full-coating wedge-tapered stem or proximal-coated wedge-tapered stem. Clinical outcomes were evaluated at follow-up time using mHHS questionnaire, VAS level of thigh pain, and hip ROM. Stem sagittal alignment and other radiological parameters, including combined anteversion and offset, were measured from conventional radiograph. RESULTS There were no significant differences on mHHS score, VAS level on thigh pain, and ROM between stem alignment groups. Post-operative anteversion and offset of the implant were not affected by the stem sagittal position. All influencing factors have significant effect on sagittal stem alignment. Linear regression test on femur morphology showed 0.69° increase in stem posterior tilt for every 1° increase in the anterior bowing (coeff. = 0.502). CONCLUSION Stem tilting in sagittal plane did not affect patient's functional outcome or post-operative radiological parameters. In addition, for every degree of increased anterior femoral bowing, 0.69° increase in posterior stem tilting can be expected.
Collapse
Affiliation(s)
- Erwin Ardian Noor
- Department of Orthopaedic and Traumatology, Cipto Mangunkusumo General Hospital - Faculty of Medicine Universitas Indonesia, Pangeran Diponegoro Street Number 71, Central Jakarta, Jakarta, Indonesia
| | - Ismail Hadisoebroto Dilogo
- Department of Orthopaedic and Traumatology, Cipto Mangunkusumo General Hospital - Faculty of Medicine Universitas Indonesia, Pangeran Diponegoro Street Number 71, Central Jakarta, Jakarta, Indonesia
| | - Jamot Silitonga
- Department of Orthopaedic and Traumatology, Fatmawati General Hospital, Jakarta, Indonesia
| | - Rahadiansyah Ramadhani
- Department of Orthopaedic and Traumatology, Cipto Mangunkusumo General Hospital - Faculty of Medicine Universitas Indonesia, Pangeran Diponegoro Street Number 71, Central Jakarta, Jakarta, Indonesia.
| |
Collapse
|
3
|
Rodríguez-González FA, Bartrina-Tarrio A, Gómez-Muñoz E, Garríguez-Pérez D, Echevarría-Marin M, Llanos S, Francés-Borrego A. [Translated article] Clinical results of total hip arthroplasty assisted by robotic arm in Spain: Preliminary study. Rev Esp Cir Ortop Traumatol (Engl Ed) 2024; 68:T108-T120. [PMID: 37992860 DOI: 10.1016/j.recot.2023.11.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 05/22/2023] [Indexed: 11/24/2023] Open
Abstract
OBJECTIVES Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. MATERIAL AND METHODS Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4 months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. RESULTS Average age was 67.2 years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative haemoglobin decrease of 3.08±1.08g/dl, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min -12, max 3) to 1.29mm (SD: 1.96) after surgery registered with Mako®, with an increase of an average hip length of 5.64mm (SD: 3.35). Rx simple study results show a postoperative difference between both hips of 0.5±3.08mm, which is consistent with Mako® results. Native femoral offset was stable after surgery with a showing difference both pre and post operative of the intervened hip of 0.1mm (SD: 3.7), registered with Mako®. Preoperatory modified Harris punctuation was 41.6±13.3, improving to postoperative values of 74.6±9.7 after four months since the surgery. No complications were registered in immediate postoperative (4 months). CONCLUSIONS Total hip arthroplasty robot-assisted achieves an adequate precision and repeatability of the implant positioning and the postoperative hip dysmetry without showing an increase of associated complications to the technique applied. Surgery time, complications and functional results in a short-time period are similar to conventional techniques applied to great series previously published.
Collapse
Affiliation(s)
| | | | - E Gómez-Muñoz
- Hospital Universitario Clínico San Carlos, Madrid, Spain
| | | | | | - S Llanos
- Hospital Universitario Clínico San Carlos, Madrid, Spain
| | | |
Collapse
|
4
|
Rodríguez-González FA, Bartrina-Tarrio A, Gómez-Muñoz E, Garríguez-Pérez D, Echevarría-Marin M, Llanos S, Francés-Borrego A. Clinical results of total hip arthroplasty assisted by robotic arm in Spain: Preliminary study. Rev Esp Cir Ortop Traumatol (Engl Ed) 2024; 68:108-120. [PMID: 37245634 DOI: 10.1016/j.recot.2023.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 05/21/2023] [Accepted: 05/22/2023] [Indexed: 05/30/2023] Open
Abstract
OBJECTIVES Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. MATERIAL AND METHODS Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. RESULTS Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min -12, max 3) to 1.29mm (SD: 1.96) after surgery registered with Mako®, with an increase of an average hip length of 5.64mm (SD: 3.35). Rx simple study results show a postoperative difference between both hips of 0.5±3.08mm, which is consistent with Mako® results. Native femoral offset was stable after surgery with a showing difference both pre and post operative of the intervened hip of 0.1mm (SD: 3.7), registered with Mako®. Preoperatory modified Harris punctuation was 41.6±13.3, improving to postoperative values of 74.6±9.7 after four months since the surgery. No complications were registered in immediate postoperative (4month). CONCLUSIONS Total hip arthroplasty robot-assisted achieves an adequate precision and repeatability of the implant positioning and the postoperative hip dysmetry without showing an increase of associated complications to the technique applied. Surgery time, complications and functional results in a short-time period are similar to conventional techniques applied to great series previously published.
Collapse
Affiliation(s)
| | | | - E Gómez-Muñoz
- Hospital Universitario Clínico San Carlos, Madrid, España
| | | | | | - S Llanos
- Hospital Universitario Clínico San Carlos, Madrid, España
| | | |
Collapse
|
5
|
Geelen H, Vanryckeghem V, Leirs G. Evaluation of the native femoral neck and stem version reproducibility using robotic-arm assisted direct-anterior total hip arthroplasty. Acta Orthop Belg 2023; 89:595-602. [PMID: 38205747 DOI: 10.52628/89.4.10411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
The intraoperative measurement of the femoral version (FV) has gained attention in wake of an optimised combined version (CV) philosophy. Whereas some data is available utilising different approaches, to our belief this study provides the first in vivo FV data in DA-THA using the MAKO™ robot. To improve the accuracy of the femoral stem version in DA-THA, we want to ask the following question: How effectively can we reproduce the native femoral version in DA- THA using the MAKO™ robot? The first 125 total hip cases through DAA with the use of the combined anteversion concept and the help of the MAKO™ robot from a single institution, single surgeon from January 2020 to July 2021 were retrospectively analysed. The native version (NV) and broach version (BV) were determined with the use of the MAKO™ preoperative computed tomography planning software. The data of the NV and BV of 115 withheld patients was normally distributed. The native femoral version ranged from -12° till 33° (mean 7,8° +/- 8,1) and the broach version ranged from -18° till 43° (mean 8,2° +/- 9,9). The Pearson correlation coefficient between the NV and BV was 0,78. The native femoral version can be reproduced by broaching the proximal femur, in a robotically implanted direct anterior cementless THA, with 78% effectiveness. Stem placement seemed to be more precise with growing experience, however this appeared not to be significant.
Collapse
|
6
|
Soliman MM, Islam MT, Chowdhury MEH, Alqahtani A, Musharavati F, Alam T, Alshammari AS, Misran N, Soliman MS, Mahmud S, Khandakar A. Advancement in total hip implant: a comprehensive review of mechanics and performance parameters across diverse novelties. J Mater Chem B 2023; 11:10507-10537. [PMID: 37873807 DOI: 10.1039/d3tb01469j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
The UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) of 2022 revealed that total hip replacement (THR) is the most common orthopaedic joint procedure. The NJR also noted that 10-20% of hip implants require revision within 1 to 10 years. Most of these revisions are a result of aseptic loosening, dislocation, implant wear, implant fracture, and joint incompatibility, which are all caused by implant geometry disparity. The primary purpose of this review article is to analyze and evaluate the mechanics and performance factors of advancement in hip implants with novel geometries. The existing hip implants can be categorized based on two parts: the hip stem and the joint of the implant. Insufficient stress distribution from implants to the femur can cause stress shielding, bone loss, excessive micromotion, and ultimately, implant aseptic loosening due to inflammation. Researchers are designing hip implants with a porous lattice and functionally graded material (FGM) stems, femur resurfacing, short-stem, and collared stems, all aimed at achieving uniform stress distribution and promoting adequate bone remodeling. Designing hip implants with a porous lattice FGM structure requires maintaining stiffness, strength, isotropy, and bone development potential. Mechanical stability is still an issue with hip implants, femur resurfacing, collared stems, and short stems. Hip implants are being developed with a variety of joint geometries to decrease wear, improve an angular range of motion, and strengthen mechanical stability at the joint interface. Dual mobility and reverse femoral head-liner hip implants reduce the hip joint's dislocation limits. In addition, researchers reveal that femoral headliner joints with unidirectional motion have a lower wear rate than traditional ball-and-socket joints. Based on research findings and gaps, a hypothesis is formulated by the authors proposing a hip implant with a collared stem and porous lattice FGM structure to address stress shielding and micromotion issues. A hypothesis is also formulated by the authors suggesting that the utilization of a spiral or gear-shaped thread with a matched contact point at the tapered joint of a hip implant could be a viable option for reducing wear and enhancing stability. The literature analysis underscores substantial research opportunities in developing a hip implant joint that addresses both dislocation and increased wear rates. Finally, this review explores potential solutions to existing obstacles in developing a better hip implant system.
Collapse
Affiliation(s)
- Md Mohiuddin Soliman
- Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Mohammad Tariqul Islam
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Muhammad E H Chowdhury
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| | - Abdulrahman Alqahtani
- Department of Medical Equipment Technology, College of Applied, Medical Science, Majmaah University, Majmaah City 11952, Saudi Arabia
- Department of Biomedical Technology, College of Applied Medical Sciences in Al-Kharj, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia.
| | - Farayi Musharavati
- Department of Mechanical & Industrial Engineering, Qatar University, Doha 2713, Qatar.
| | - Touhidul Alam
- Pusat Sains Ankasa (ANGKASA), Institut Perubahan Iklim, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Selangor, Malaysia.
| | - Ahmed S Alshammari
- Department of Electrical Engineering, College of Engineering, University Hail, Hail 81481, Saudi Arabia.
- Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
| | - Norbahiah Misran
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Mohamed S Soliman
- Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
- Department of Electrical Engineering, Faculty of Energy Engineering, Aswan University, Aswan, 81528, Egypt
| | - Sakib Mahmud
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| | - Amith Khandakar
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| |
Collapse
|
7
|
Femoral Anteversion in Total Hip Arthroplasty: Retrospective Comparison of Short- and Straight-Stem Models Using CT Scans. J Clin Med 2023; 12:jcm12062391. [PMID: 36983391 PMCID: PMC10058265 DOI: 10.3390/jcm12062391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 03/08/2023] [Accepted: 03/16/2023] [Indexed: 03/22/2023] Open
Abstract
Data on reconstruction of the femoral anteversion (FA) and the center of rotation after total hip arthroplasty (THA) are rare. We aimed to answer whether a short-stem fixation enables improved anatomical reconstruction of the FA compared to a straight-stem. Methods: One hundred and thirty patients who underwent short- (n = 89, group A, prospective) or straight-stem THA (n = 41, group B, retrospective) were included. CT scans of the hip, knee, and ankle were performed pre- and postoperatively in group A and in group B during the last follow-up. Femoral torsion was determined using three-dimensional models. Results: The mean preoperative FA was 22.4° ± 11.0°, and the mean postoperative FA was 23.4° ± 10.1°. The relative difference was −0.8° ± 8°, and the absolute difference was 6.4° ± 4.9°. Gender analysis revealed significant differences in preoperative FA between female (f) and male (m) patients (28.1° ± 11.2° (f) vs. 18.4° ± 8.3° (m); p > 0.001) as well as in postoperative FA (26.7° ± 23.5° (f) vs. 21.0° ± 9.7° (m); p < 0.007) in group A. Postoperative FA was higher in group A (mean 6.8°; 23.9° ± 10.1° (f) vs. 16.6° ± 8.6° (m); p < 0.001). Conclusions: The study’s findings suggest that short-stem THA leads to improved anatomical FA reconstruction; however, a substantial postoperative gender-related FA difference was detectable, which may warrant consideration by surgeons when determining the final stem anteversion. It should be noted that the impact of the postoperative gender-related FA difference on clinical outcomes is not entirely clear, and further research is warranted to elucidate this relationship.
Collapse
|
8
|
Hochreiter J, Böhm G, Fierlbeck J, Anderl C, Birke M, Münger P, Ortmaier R. Femoral antetorsion after calcar-guided short-stem total hip arthroplasty: A cadaver study. J Orthop Res 2022; 40:2127-2132. [PMID: 34873734 PMCID: PMC9540338 DOI: 10.1002/jor.25228] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 10/19/2021] [Accepted: 11/20/2021] [Indexed: 02/04/2023]
Abstract
Calcar-guided short stems in total hip arthroplasty (THA) permit surgeons to successfully reconstruct postoperative femoroacetabular offset, accurately restore leg length, and adequately re-establish a wide range of caput-collum-diaphyseal angles. However, their effect on femoral antetorsion is less known. Indeed, controlling antetorsion of the femoral stem can be challenging because of the differences in individual femoral geometry and curvature. Therefore, we investigated if calcar-guided short-stem THA alters femoral antetorsion and compared it with conventional-stem THA. Using 12 Thiel-fixed, full-body cadaver specimens from donors without known hip disorders, we compared an uncemented calcar-guided femoral short-stem prosthesis with an uncemented conventional straight-stem prosthesis. In a paired study setup, each specimen received a calcar-guided short stem on one side and a conventional stem on the other. On the acetabular side, all specimens received a press-fit, monobloc acetabular cup. Femoral antetorsion angles were measured using the Waidelich method, and pre- and post-operative angles of both sides were recorded. The mean preoperative femoral antetorsion angles were similar in both groups (24.8° ± 7.5° vs. 23.8° ± 6.1°, p = 0.313). Mean postoperative femoral antetorsion angles were 23.0° ± 5.5° in short-stem and 13.5° ± 7.1° in conventional-stem hips. Short-stem hips had a small but nonsignificant difference in femoral antetorsion angles pre- and post-operatively (1.8° ± 3.2°, p = 0.109), while the difference for conventional-stem hips was much larger and highly significant (10.3° ± 5.8°, p < 0.001). Calcar-guided short-stem THA effectively restores femoral antetorsion. However, how this affects long-term clinical outcomes and complications warrants further exploration.
Collapse
Affiliation(s)
- Josef Hochreiter
- Department of Orthopedic Surgery, Ordensklinikum Linz GmbHBarmherzige Schwestern HospitalLinzAustria,Department of Orthopedics and TraumatologyParacelsus Medical UniversitySalzburgAustria
| | - Gernot Böhm
- Department of Diagnostic and Interventional RadiologyOrdensklinikum Linz GmbHLinzAustria
| | - Johann Fierlbeck
- Institute for Clinical InnovationParacelsus Medical UniversitySalzburgAustria
| | - Conrad Anderl
- Department of Orthopedic Surgery, Ordensklinikum Linz GmbHBarmherzige Schwestern HospitalLinzAustria
| | - Marco Birke
- Institute of Anatomy and Cell BiologyParacelsus Medical UniversitySalzburgAustria
| | | | - Reinhold Ortmaier
- Department of Orthopedic Surgery, Ordensklinikum Linz GmbHBarmherzige Schwestern HospitalLinzAustria,Department of Orthopedics and TraumatologyParacelsus Medical UniversitySalzburgAustria,Research Unit of Orthopedic Sports Medicine and Injury Prevention, Institute for Sports Medicine, Alpine Medicine and Health Tourism, UMIT Private University for Health SciencesMedical Informatics and Technology GmbHHall in TirolAustria
| |
Collapse
|
9
|
Kamath AF, Durbhakula SM, Pickering T, Cafferky NL, Murray TG, Wind MA, Méthot S. Improved accuracy and fewer outliers with a novel CT-free robotic THA system in matched-pair analysis with manual THA. J Robot Surg 2022. [PMID: 34709535 DOI: 10.1007/s11701-021-01315-3/figures/5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2023]
Abstract
Accurate component orientation and restoration of hip biomechanics remains a continuing challenge in total hip arthroplasty (THA). The goal of this study was to analyze the accuracy/reproducibility of a novel CT-free and pin-less robotic-assisted THA (RA-THA) platform compared to manual THA (mTHA). This matched-pair cadaveric study compared this RA-THA system to mTHA (n = 33/arm), both using the assistance of fluoroscopic imaging, in a group of 14 high-volume arthroplasty surgeons. In both groups, surgeons were asked to aim for 40°/15° for cup inclination/version, and 0 mm of leg length discrepancy (LLD). A validated and accurate method using radio-opaque markers measured cup inclination/version and LLD. The accuracy and reproducibility (fewer outliers) of cup inclination was significantly improved in the robotic group (1.8° ± 1.3° vs 6.4° ± 4.9°, respectively, robotic vs manual; p < 0.001), with no significant difference between groups for version. The reproducibility of LLD was significantly improved in the robotic group (p = 0.003). For all parameters studied, the robotic group had an improved accuracy and lower variance (fewer outliers). The percentage of cases within the more restrictive Callanan safe zone was 100% for RA-THA vs 73% for mTHA (p = 0.002). The CT-free RA-THA platform, using only fluoroscopic imaging, demonstrated more accurate acetabular cup positioning, when compared to the mTHA procedures performed by high-volume hip surgeons (naive to this RA-THA platform), with respect to cup inclination and placement within the Lewinnek/Callanan safe zones. Future study must incorporate economic factors, lower volume surgeons, clinical and patient-centric outcomes, and other radiographic parameters in controlled studies in large sample sizes.
Collapse
Affiliation(s)
- Atul F Kamath
- Orthopaedic and Rheumatologic Institute, Cleveland Clinic, 9500 Euclid Avenue, A40, Cleveland, OH, 44195, USA.
| | | | - Trevor Pickering
- Mississippi Sports Medicine and Orthopaedic Center, Jackson, MS, 39202, USA
| | | | - Trevor G Murray
- Orthopaedic and Rheumatologic Institute, Cleveland Clinic, 9500 Euclid Avenue, A40, Cleveland, OH, 44195, USA
| | | | | |
Collapse
|
10
|
Beckmann NA, Schonhoff M, Bastian JD, Renkawitz T, Jaeger S. Dissociation of liner from cup in THA: does liner damage affect the risk of dissociation? Arch Orthop Trauma Surg 2022; 143:2747-2754. [PMID: 35788763 PMCID: PMC10110686 DOI: 10.1007/s00402-022-04529-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 06/16/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION A rare catastrophic failure of modular component Total Hip Arthroplasty is dissociation between liner and cup, which has been associated with component malposition and/or impingement and seems to be more frequently associated with the Pinnacle system. The goal of this study was to evaluate the resistance of a polyethylene liner to lever-out-forces of the Pinnacle locking mechanism and the locking mechanisms of two other current cup/liner systems using a standardized testing method (ASTM). MATERIALS AND METHODS Five of each of the following cups were evaluated with their corresponding polyethylene liners: Pinnacle Multihole cup with and without intact anti-rotation tabs (ART's); Allofit-S-Alloclassic and Plasmafit Plus7 cups. The ASTM test set-up was used to evaluate the lever-out force resulting in liner dissociation for each construct. RESULTS The Pinnacle construct with intact ARTs required the greatest force (F) to achieve dissociation (263.2 ± 79.2 N) followed by the Plasmafit Plus7 (185.8 ± 36.9 N) and the Allofit-S (101.4 ± 35.3 N) constructs, respectively. However, after removal of the ARTs, the Pinnacle system required the least force to achieve dissociation (75.1 ± 22.2 N) (p < 0.001). CONCLUSIONS The intact Pinnacle system appeared the most stable in lever-out tests when compared to the other systems. However, after removal of the ARTs, the Pinnacle system required the least force for dissociation, consistent with locking mechanism failure, and suggesting that the ARTs are a critical component of the locking mechanism. Our findings are consistent with the clinical experience of dissociated Pinnacle constructs displaying damaged or missing ARTs, and that damage to these may increase risk of liner dissociation.
Collapse
Affiliation(s)
- Nicholas Andreas Beckmann
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
| | - Mareike Schonhoff
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Johannes Dominik Bastian
- Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Tobias Renkawitz
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - Sebastian Jaeger
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
11
|
van Erp JHJ, Snijders TE, Weinans H, Castelein RM, Schlösser TPC, de Gast A. The role of the femoral component orientation on dislocations in THA: a systematic review. Arch Orthop Trauma Surg 2022; 142:1253-1264. [PMID: 34101017 PMCID: PMC9110501 DOI: 10.1007/s00402-021-03982-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 05/26/2021] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Dislocation remains a major complication in total hip arthroplasty (THA), in which femoral component orientation is considered a key parameter. New imaging modalities and definitions on femoral component orientation have been introduced, describing orientation in different planes. This study aims to systematically review the relevance of the different orientation parameters on implant stability. METHODS A systematic review was performed according to the PRISMA guidelines to identify articles in the PubMed and EMBASE databases that study the relation between any femoral component orientation parameters and implant stability in primary THA. RESULTS After screening for inclusion and exclusion criteria and quality assessment, nine articles were included. Definitions to describe the femoral component orientation and methodologies to assess its relevance for implant stability differed greatly, with lack of consensus. Seven retrospective case-control studies reported on the relevance of the transversal plane orientation: Low femoral- or low combined femoral and acetabular anteversion was statistical significantly related with more posterior dislocations, and high femoral- or combined femoral and acetabular anteversion with anterior dislocations in two studies. There were insufficient data on sagittal and coronal component orientation in relation to implant stability. CONCLUSION Because of incomparable definitions, limited quality and heterogeneity in methodology of the included studies, there is only weak evidence that the degree of transverse component version is related with implant stability in primary THA. Recommendations about the optimal orientation of the femoral component in all three anatomical planes cannot be provided. Future studies should uniformly define the three-dimensional orientation of the femoral component and systematically describe implant stability.
Collapse
Affiliation(s)
- Joost H. J. van Erp
- Department of Orthopedics, Diakonessenhuis, Utrecht, Zeist, The Netherlands
- Clinical Orthopedic Research Center m-N, Zeist, The Netherlands
- Department of Orthopedics, UMC Utrecht, Utrecht, The Netherlands
| | - Thom E. Snijders
- Department of Orthopedics, Diakonessenhuis, Utrecht, Zeist, The Netherlands
- Clinical Orthopedic Research Center m-N, Zeist, The Netherlands
| | - Harrie Weinans
- Department of Orthopedics, UMC Utrecht, Utrecht, The Netherlands
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | | | | | - Arthur de Gast
- Department of Orthopedics, Diakonessenhuis, Utrecht, Zeist, The Netherlands
- Clinical Orthopedic Research Center m-N, Zeist, The Netherlands
| |
Collapse
|
12
|
Hidaka R, Matsuda K, Nakamura M, Nakamura S, Kawano H. Optimal combined anteversion range for obtaining a wider range of motion without prosthetic impingement after total hip arthroplasty: a three-dimensional analysis study. J Orthop Surg Res 2022; 17:226. [PMID: 35399103 PMCID: PMC8996486 DOI: 10.1186/s13018-022-03112-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 03/31/2022] [Indexed: 11/10/2022] Open
Abstract
Background Obtaining a larger theoretical range of motion (ROM) is crucial to avoid prosthetic impingement after total hip arthroplasty (THA); however, no reports have examined the permissible range values of combined anteversion (CA) satisfying targeted ROM without prosthetic impingement. This retrospective study aimed to evaluate the possible postoperative CA extent that would allow meeting target ROM criteria according to Yoshimine’s theory using computed tomography (CT)-based three-dimensional motion analysis after THA. Methods This study included 114 patients (133 hips) who underwent cementless primary THA using a CT-based navigation system and implants (oscillation angle ≥ 135°). Implant positions were determined using Yoshimine's CA formula. Postoperative evaluation was conducted using a three-dimensional templating software for CT data. The postoperative Yoshimine’s and Widmer’s CA was calculated, and the difference between the target and postoperative values was defined as the error of Yoshimine’s CA and Widmer’s CA. Prosthetic ROM was assessed by Yoshimine’s stringent criteria for activities of daily living. Based on fulfilling these criteria, all patients were divided into the ROM (+) and ROM (−) groups. Evaluation items were compared between the two groups. Results There were 111 and 22 hips in the ROM (+) and ROM (−) groups, respectively. A significant difference was noted in the absolute error of Yoshimine’s and Widmer’s CA between the two groups. Using receiver operating characteristic analysis, threshold values of 6.0 (higher values indicate greater disability; sensitivity 90.9%, specificity 72.1%) for the absolute Yoshimine’s CA difference (area under the curve [AUC] 0.87, P < 0.01) and 6.9 (higher values indicate greater disability; sensitivity 68.2%, specificity 88.3%) for the absolute Widmer’s CA difference (AUC 0.83, P < 0.01) were predictors in the ROM (−) group. Conclusions The target range of Yoshimine’s CA (90.8° ± 6.0°) and Widmer’s CA values (37.3° ± 6.9°) was crucial in implant orientation for obtaining theoretical ROM without prosthetic impingement after THA.
Collapse
|
13
|
Improved accuracy and fewer outliers with a novel CT-free robotic THA system in matched-pair analysis with manual THA. J Robot Surg 2021; 16:905-913. [PMID: 34709535 PMCID: PMC9314281 DOI: 10.1007/s11701-021-01315-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 10/03/2021] [Indexed: 11/26/2022]
Abstract
Accurate component orientation and restoration of hip biomechanics remains a continuing challenge in total hip arthroplasty (THA). The goal of this study was to analyze the accuracy/reproducibility of a novel CT-free and pin-less robotic-assisted THA (RA-THA) platform compared to manual THA (mTHA). This matched-pair cadaveric study compared this RA-THA system to mTHA (n = 33/arm), both using the assistance of fluoroscopic imaging, in a group of 14 high-volume arthroplasty surgeons. In both groups, surgeons were asked to aim for 40°/15° for cup inclination/version, and 0 mm of leg length discrepancy (LLD). A validated and accurate method using radio-opaque markers measured cup inclination/version and LLD. The accuracy and reproducibility (fewer outliers) of cup inclination was significantly improved in the robotic group (1.8° ± 1.3° vs 6.4° ± 4.9°, respectively, robotic vs manual; p < 0.001), with no significant difference between groups for version. The reproducibility of LLD was significantly improved in the robotic group (p = 0.003). For all parameters studied, the robotic group had an improved accuracy and lower variance (fewer outliers). The percentage of cases within the more restrictive Callanan safe zone was 100% for RA-THA vs 73% for mTHA (p = 0.002). The CT-free RA-THA platform, using only fluoroscopic imaging, demonstrated more accurate acetabular cup positioning, when compared to the mTHA procedures performed by high-volume hip surgeons (naive to this RA-THA platform), with respect to cup inclination and placement within the Lewinnek/Callanan safe zones. Future study must incorporate economic factors, lower volume surgeons, clinical and patient-centric outcomes, and other radiographic parameters in controlled studies in large sample sizes.
Collapse
|
14
|
O'Connor PB, Thompson MT, Esposito CI, Poli N, McGree J, Donnelly T, Donnelly W. The impact of functional combined anteversion on hip range of motion: a new optimal zone to reduce risk of impingement in total hip arthroplasty. Bone Jt Open 2021; 2:834-841. [PMID: 34633223 PMCID: PMC8558443 DOI: 10.1302/2633-1462.210.bjo-2021-0117.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
AIMS Pelvic tilt (PT) can significantly change the functional orientation of the acetabular component and may differ markedly between patients undergoing total hip arthroplasty (THA). Patients with stiff spines who have little change in PT are considered at high risk for instability following THA. Femoral component position also contributes to the limits of impingement-free range of motion (ROM), but has been less studied. Little is known about the impact of combined anteversion on risk of impingement with changing pelvic position. METHODS We used a virtual hip ROM (vROM) tool to investigate whether there is an ideal functional combined anteversion for reduced risk of hip impingement. We collected PT information from functional lateral radiographs (standing and sitting) and a supine CT scan, which was then input into the vROM tool. We developed a novel vROM scoring system, considering both seated flexion and standing extension manoeuvres, to quantify whether hips had limited ROM and then correlated the vROM score to component position. RESULTS The vast majority of THA planned with standing combined anteversion between 30° to 50° and sitting combined anteversion between 45° to 65° had a vROM score > 99%, while the majority of vROM scores less than 99% were outside of this zone. The range of PT in supine, standing, and sitting positions varied widely between patients. Patients who had little change in PT from standing to sitting positions had decreased hip vROM. CONCLUSION It has been shown previously that an individual's unique spinopelvic alignment influences functional cup anteversion. But functional combined anteversion, which also considers stem position, should be used to identify an ideal THA position for impingement-free ROM. We found a functional combined anteversion zone for THA that may be used moving forward to place total hip components. Cite this article: Bone Jt Open 2021;2(10):834-841.
Collapse
Affiliation(s)
- Patrick B O'Connor
- St Vincent's Private Hospital Northside, Brisbane, Queensland, Australia
| | | | | | - Nikola Poli
- Queensland University of Technology, Brisbane, Queensland, Australia
| | - James McGree
- Queensland University of Technology, Brisbane, Queensland, Australia
| | - Thomas Donnelly
- St Vincent's Private Hospital Northside, Brisbane, Queensland, Australia
| | - William Donnelly
- St Vincent's Private Hospital Northside, Brisbane, Queensland, Australia
| |
Collapse
|
15
|
Emara AK, Samuel LT, Acuña AJ, Kuo A, Khlopas A, Kamath AF. Robotic-arm assisted versus manual total hip arthroplasty: Systematic review and meta-analysis of radiographic accuracy. Int J Med Robot 2021; 17:e2332. [PMID: 34528372 DOI: 10.1002/rcs.2332] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 08/14/2021] [Accepted: 09/14/2021] [Indexed: 12/19/2022]
Abstract
BACKGROUND We systematically reviewed the radiological outcomes of studies comparing robotic-assisted (RA-THA) and manual total hip arthroplasty (mTHA). METHODS The PubMed, Embase, and Cochrane databases were queried from 1994-2021 for articles comparing radiographic outcomes between RA-THA and mTHA cohorts. A meta-analysis was conducted whenever sufficient data was present for common outcomes. RESULTS Our analysis included 20 articles reporting on 4140 patients (RA-THA: n = 1228; mTHA: n = 2912). No differences were demonstrated for acetabular inclination or anteversion. However, RA-THA demonstrated higher rates of cup orientation within the Lewinnek and Callanan safe zones, improved femoral stem alignment, and lower global offset difference (GOD) and limb length discrepancy (all p-values <0.05). Superior femoral canal fill and combined offset were seen among RA-THA patients. CONCLUSION Our review found that the use of RA-THA yields superior radiographic outcomes compared to mTHA counterparts. This information can inform healthcare systems considering investing in and implementing these technologies.
Collapse
Affiliation(s)
- Ahmed K Emara
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio, 44195, USA
| | - Linsen T Samuel
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio, 44195, USA
| | - Alexander J Acuña
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio, 44195, USA
| | - Andy Kuo
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio, 44195, USA
| | - Anton Khlopas
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio, 44195, USA
| | - Atul F Kamath
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio, 44195, USA
| |
Collapse
|
16
|
The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation. SENSORS 2021; 21:s21124232. [PMID: 34203107 PMCID: PMC8234047 DOI: 10.3390/s21124232] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/12/2021] [Accepted: 06/18/2021] [Indexed: 01/13/2023]
Abstract
The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intraoperatively. The main purpose of this study was to verify the reliability and accuracy of a patient-specific instrumentation (PSI) and laser-guided technique to replicate preoperative dynamic planning. Thirty-six patients were prospectively enrolled and received dynamic hip preoperative planning based on three functional lateral spinopelvic X-rays and a low dose CT scan. Three-dimensional (3D) printed PSI guides and laser-guided instrumentation were used intraoperatively. The orientation of the components, osteotomy level and change in hip length and offset were measured on postoperative CT scans and compared with the planned preoperative values. The length of surgery was compared with that of a matched group of thirty-six patients who underwent a conventional THA. The mean absolute deviation from the planned inclination and anteversion was 3.9° and 4.4°, respectively. In 92% of cases, both the inclination and anteversion were within +/− 10° of the planned values. Regarding the osteotomy level, offset change and limb length change, the mean deviation was, respectively, 1.6 mm, 2.6 mm and 2 mm. No statistically significant difference was detected when comparing the planned values with the achieved values. The mean surgical time was 71.4 min in the PSI group and 60.4 min in the conventional THA group (p < 0.05). Patient-specific and laser-guided instrumentation is safe and accurately reproduces dynamic planning in terms of the orientation of the components, osteotomy level, leg length and offset. Moreover, the increase in surgical time is negligible.
Collapse
|
17
|
Jackson JB, Martin JR, Christal A, Masonis JL, Springer BD, Mason JB. The Direct Anterior Approach Total Hip Arthroplasty Reliably Achieves "Safe Zones" for Combined Anteversion. Arthroplast Today 2020; 6:651-654. [PMID: 32875014 PMCID: PMC7451890 DOI: 10.1016/j.artd.2020.07.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 06/19/2020] [Accepted: 07/11/2020] [Indexed: 11/26/2022] Open
Abstract
Background In total hip arthroplasty (THA), component position is critical to avoid instability and improve longevity. Appropriate combined femoral and acetabular component anteversion is important for improved THA stability and increased impingement-free range of motion. In direct anterior THA (DA-THA), concern has been expressed regarding the accuracy of femoral component positioning. This study seeks to quantify acetabular, femoral, and combined component orientation relative to the accepted “safe zones” in patients who have undergone DA-THA. Methods Twenty-nine patients who had THA performed via direct anterior approach had postoperative computerized tomography scans done to assess femoral anteversion. Stem rotational alignment was measured relative to the transepicondylar axis (TEA) and the posterior condylar axis (PCA) of the femur at the knee. Acetabular abduction and version were recorded on anteroposterior pelvis radiographs. Results The mean stem anteversion was 17.5° (standard deviation = 10.8°) from the TEA and 21.7° (standard deviation = 11.3°) from the PCA. Ten of 30 cups were appropriately anteverted; however, all the cups had appropriate abduction. Combined version when using the TEA resulted in 79% (23/29) of patients within the “safe zone” of 25°-50°. Pearson correlation coefficients were high for both stem anteversion from the TEA (R = 0.96) and PCA (R = 0.98); however, interobserver reliability for combined component anteversion was greater for the TEA (kappa, 0.83 vs 0.65). Conclusions Combined anteversion within the “safe zone” was achieved 79% of the time with DA-THA. Interestingly, most of the “excessive” combined anteversion appears to be related to increased anteversion of the acetabular component with only 10 patients within the acetabular cup “safe zone” of 5°-25°.
Collapse
|
18
|
Flevas DA, Tsantes AG, Mavrogenis AF. Direct Anterior Approach Total Hip Arthroplasty Revisited. JBJS Rev 2020; 8:e0144. [DOI: 10.2106/jbjs.rvw.19.00144] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
19
|
Tanaka T, Takao M, Sakai T, Hamada H, Tanaka S, Sugano N. Variations in sagittal and coronal stem tilt and their impact on prosthetic impingement in total hip arthroplasty. Artif Organs 2018; 43:569-576. [PMID: 30412266 DOI: 10.1111/aor.13388] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 11/02/2018] [Accepted: 11/02/2018] [Indexed: 11/28/2022]
Abstract
Optimization of the combined anteversion of cup and stem has been emphasized to avoid prosthetic impingement in total hip arthroplasty (THA). However, no study has focused on the impact of variations in sagittal and coronal stem tilt against the whole femur on prosthetic range of motion. The purposes of the present study were a) to quantify the anatomical variation of sagittal and coronal tilt of the proximal canal axis against the femoral retrocondylar coordinate system, that is variation of sagittal and coronal stem tilt and b) to determine their impact on the zone of impingement-free cup position using computer simulation. Preoperative computed tomography images of 477 femurs from 409 consecutive patients who underwent THA using computed tomography-based computer navigation were stored. Virtual implantation of an anatomical stem was performed on the navigation workstation. The safe zone of the cup position with regard to prosthetic impingement was determined by motion simulation in the range of sagittal and coronal stem tilt of the subjects. The sagittal and coronal stem tilt varied by 10°, which was smaller than the stem anteversion variation. However, there was about 3 times the difference in the impingement-free zone of cup position in the ranges of sagittal and coronal stem tilt. The safe zone was significantly decreased by posterior tilt and valgus tilt of the stem. Range of motion simulation revealed that the variations in sagittal or coronal stem tilt significantly influenced the safe zone of the cup. In conclusion, although the variations in sagittal and coronal stem tilt against the femoral retrocondylar coordinate system were small, their impact on prosthetic impingement was significant.
Collapse
Affiliation(s)
- Takeyuki Tanaka
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan.,Orthopaedic Surgery, Sensory and Motor System Medicine, Surgical Sciences, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Masaki Takao
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Takashi Sakai
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Sakae Tanaka
- Orthopaedic Surgery, Sensory and Motor System Medicine, Surgical Sciences, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
20
|
Myers CA, Laz PJ, Shelburne KB, Judd DL, Huff DN, Winters JD, Stevens-Lapsley JE, Rullkoetter PJ. The impact of hip implant alignment on muscle and joint loading during dynamic activities. Clin Biomech (Bristol, Avon) 2018; 53:93-100. [PMID: 29482087 PMCID: PMC5890933 DOI: 10.1016/j.clinbiomech.2018.02.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Revised: 01/09/2018] [Accepted: 02/12/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Component alignment is an important consideration in total hip arthroplasty. The impact of changes in alignment on muscle forces and joint contact forces during dynamic tasks are not well understood, and have the potential to influence surgical decision making. The objectives of this study were to assess the impact of femoral head/stem and cup component placement on hip muscle and joint contact forces during tasks of daily living and to identify which alignment parameters have the greatest impact on joint loading. METHODS Using a series of strength-calibrated, subject-specific musculoskeletal models of patients performing gait, sit-to-stand and step down tasks, component alignments were perturbed and joint contact and muscle forces evaluated. FINDINGS Based on the range of alignments reported clinically, variation in head/stem anteversion-retroversion had the largest impact of any degree of freedom throughout all three tasks; average contact forces 413.5 (319.1) N during gait, 262.7 (256.4) N during sit to stand, and 572.7 (228.1) N during the step down task. The sensitivity of contact force to anteversion-retroversion of the head/stem was 31.5 N/° for gait, which was similar in magnitude to anterior-posterior position of the cup (34.6 N/m for gait). Additionally, superior-inferior cup alignment resulted in 16.4 (4.9)° of variation in the direction of the hip joint contact force across the three tasks, with the most inferior cup placements moving the force vector towards the cup equator at the point of peak joint contact force. INTERPRETATION A quantitative understanding of the impact and potential tradeoffs when altering component alignment is valuable in supporting surgical decision making.
Collapse
Affiliation(s)
- Casey A Myers
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA.
| | - Peter J Laz
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| | - Kevin B Shelburne
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| | - Dana L Judd
- Physical Therapy Program, University of Colorado, Aurora, CO, USA
| | | | - Joshua D Winters
- Physical Therapy Program, University of Colorado, Aurora, CO, USA
| | - Jennifer E Stevens-Lapsley
- Physical Therapy Program, University of Colorado, Aurora, CO, USA; Geriatric Research Education and Clinical Center, VA Eastern Colorado Healthcare System, Denver, CO, USA
| | - Paul J Rullkoetter
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| |
Collapse
|
21
|
Pierrepont J, Yang L, Arulampalam J, Stambouzou C, Miles B, Li Q. The effect of seated pelvic tilt on posterior edge-loading in total hip arthroplasty: A finite element investigation. Proc Inst Mech Eng H 2018; 232:241-248. [DOI: 10.1177/0954411917752028] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Edge-loading of a ceramic-on-ceramic total hip replacement can lead to reproducible squeaking and revision. A patient’s functional acetabular cup orientation, driven by their pelvic tilt, has been shown to be a significant factor in squeaking during hip flexion. The aim of this study was to investigate the effect of seated pelvic tilt on the contact mechanics at the ceramic bearing surface. A finite element model of a ceramic-on-ceramic total hip replacement was created. The cup was orientated at 40° inclination and 15° anteversion relative to the anterior pelvic plane. The stem was flexed 90° to replicate sitting in a chair. The model was loaded using data from in vivo measurements taken during a sit-to-stand activity. The pelvis was modelled in seven different sagittal positions, ranging from −30° to 30° of pelvic tilt, where a positive value denotes anterior pelvic tilt. Three different head sizes were investigated: 32, 36 and 40 mm. The maximum contact pressure and contact patch to rim distance were determined for each of the 21 simulations. Edge-loading (contact patch to rim distance < 0 mm) occurred with all head sizes when seated pelvic tilt was ≥10° and induced a large increase in contact pressure on the liner, with a maximum pressure exceeding 500 MPa. Edge-loading initiated at seated pelvic tilts of 7°, 9° and 5° for the 32, 36 and 40 mm heads, respectively. Patients with anterior pelvic tilts in the seated position are susceptible to posterior edge-loading. As the position of the pelvis when seated is patient specific, cup orientation should be adjusted on an individual basis to minimise edge-loading.
Collapse
Affiliation(s)
- Jim Pierrepont
- School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, Sydney, NSW, Australia
- Optimized Ortho, Millers Point, NSW, Australia
| | | | | | | | | | - Qing Li
- School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
22
|
Akiyama K, Shibuya T. Influence of femoral bowing on range of motion after total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2017; 42:1795-1802. [PMID: 29275431 DOI: 10.1007/s00264-017-3732-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Accepted: 12/10/2017] [Indexed: 11/29/2022]
Abstract
PURPOSE The influence of physiologic femoral bowing on range of motion (ROM) after total hip arthroplasty (THA) remains unknown. The purpose of this study was to investigate the morphology of the femur in patients who underwent THA, and to analyze the influence of femoral bowing on ROM due to implant impingement after THA. METHODS The ROM was calculated from 100 hips in 90 patients who underwent THA using computed tomography data with a 3D dynamic analysis software. Lateral and anterior bowing angles of the femur were measured. A modular implant (Modulus system, Lima Corporate, Villanova di San Daniele del Friuli, Italy) was used for simulation. In all subjects, cup inclination, anteversion, and stem anteversion were set to 40°, 15°, and 30°, respectively. Multiple linear regression analyses were performed to assess the relationship between the morphology of the femur and ROM. RESULTS Lateral bowing of the femur was demonstrated to be significantly correlated with age (r = 0.361, p < 0.001) and female sex (r = 0.315, p = 0.001). Lateral bowing of the femur was significantly positively correlated with flexion and internal rotation (Int-R) with 90° flexion. Anterior bowing was significantly associated with decreasing flexion, decreasing Int-R with 90° flexion and increasing Int-R with 45° flexion and 15° adduction. CONCLUSIONS A ROM-optimized cup position cannot be calculated from femoral stem anteversion values alone; therefore, when surgeons position the cup in relation to the femoral stem anteversion, the influence of femoral bowing may also require consideration.
Collapse
Affiliation(s)
- Keisuke Akiyama
- Department of Orthopaedic Surgery, National Hospital Organization, Osaka Minami Medical Center, 2-1 Kidohigashi, Kawachinagano City, Osaka, 586-0008, Japan.
| | - Takaaki Shibuya
- Department of Orthopaedic Surgery, Sumitomo Hospital, 5-3-20, Nakanoshima, Kita-ku, Osaka City, 530-0005, Japan
| |
Collapse
|
23
|
Weber M, Woerner ML, Sendtner E, Völlner F, Grifka J, Renkawitz TF. Even the Intraoperative Knowledge of Femoral Stem Anteversion Cannot Prevent Impingement in Total Hip Arthroplasty. J Arthroplasty 2016; 31:2514-2519. [PMID: 27236745 DOI: 10.1016/j.arth.2016.04.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2016] [Revised: 04/16/2016] [Accepted: 04/21/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In this prospective study of 66 patients undergoing cementless total hip arthroplasty through a minimally invasive anterolateral approach, we evaluated the impact of an intraoperative hybrid combined anteversion technique on postoperative range of motion (ROM). METHODS After navigation of femoral stem anteversion, trial acetabular components were positioned manually, and their position recorded with navigation. Then, final components were implanted with navigation at the goals prescribed by the femur-first impingement detection algorithm. Postoperatively, three-dimensional computed tomographies were performed to determine achieved component position and model impingement-free ROM by virtual hip movement, which was compared with published values necessary for activities of daily living. This model was run a second time with the implants in the position selected by the surgeon rather than the navigation program. In addition, we researched into risk factors for ROM differences between the freehand and navigated cup position. RESULTS We found a lower flexion of 8.3° (8.8°, P < .001) and lower internal rotation of 9.2° (9.5°, P < .001) for the freehand implanted cups in contrast to a higher extension of 9.8° (11.8°, P < .001) compared with the navigation-guided technique. For activities of daily living, 58.9% (33/56) in the freehand group compared with 85.7% (48/56) in the navigation group showed free flexion (P < .001) and similarly 50.0% (28/56) compared with 76.8% (43/56) free internal rotation (P < .001). Body mass index, incision length, and cup size were identified as independent risk factors for reduced flexion and internal rotation in the freehand group. CONCLUSION For implementation of a combined anteversion algorithm, intraoperative alignment guides for accurate cup positioning are required using a minimally invasive anterolateral approach. Obese patients are especially at risk of cup malpositioning.
Collapse
MESH Headings
- Acetabulum/surgery
- Activities of Daily Living
- Aged
- Arthroplasty, Replacement, Hip/adverse effects
- Arthroplasty, Replacement, Hip/instrumentation
- Arthroplasty, Replacement, Hip/methods
- Female
- Femoracetabular Impingement/etiology
- Femoracetabular Impingement/prevention & control
- Femur/surgery
- Hip Joint/diagnostic imaging
- Humans
- Male
- Middle Aged
- Models, Theoretical
- Postoperative Complications/etiology
- Postoperative Complications/prevention & control
- Postoperative Period
- Prospective Studies
- Range of Motion, Articular
- Rotation
- Surgery, Computer-Assisted/methods
- Tomography, X-Ray Computed
Collapse
Affiliation(s)
- Markus Weber
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| | - Michael L Woerner
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| | - Ernst Sendtner
- Department of Orthopedic and Trauma Surgery, Vilsbiburg Hospital, Vilsbiburg, Germany
| | - Florian Völlner
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| | - Joachim Grifka
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| | - Tobias F Renkawitz
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| |
Collapse
|
24
|
Worlicek M, Weber M, Craiovan B, Wörner M, Völlner F, Springorum HR, Grifka J, Renkawitz T. Native femoral anteversion should not be used as reference in cementless total hip arthroplasty with a straight, tapered stem: a retrospective clinical study. BMC Musculoskelet Disord 2016; 17:399. [PMID: 27646313 PMCID: PMC5028956 DOI: 10.1186/s12891-016-1255-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2015] [Accepted: 09/13/2016] [Indexed: 11/25/2022] Open
Abstract
Backround Improper femoral and acetabular component positioning can be associated with instability, impingement, component wear and finally patient dissatisfaction in total hip arthroplasty (THA). The concept of “femur first”/“combined anteversion”, incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position of the stem relative to the cup intraoperatively. In the present study we asked two questions: (1) Do native femoral anteversion and anteversion of the implant correlate? (2) Do anteversion of the final broach and implant anteversion correlate? Methods In a secondary analysis of a prospective controlled trial, a subgroup of 55 patients, who underwent computer-assisted, cementless THA with a straight, tapered stem through an anterolateral, minimally invasive (MIS) approach in a lateral decubitus position were examined retrospectivly. Intraoperative fluoroscopy was used to verify a “best-fit” position of the final broach. An image-free navigation system was used for measurement of the native femoral version, version of the final broach and the final implant. Femoral neck resection height was measured in postoperative CT-scans. This investigation was approved by the local Ethics Commission (No.10-121-0263) and is a secondary analysis of a larger project (DRKS00000739, German Clinical Trials Register May-02–2011). Results The mean difference between native femoral version and final implant was 1.9° (+/− 9.5), with a range from −20.7° to 21.5° and a Spearman’s correlation coefficient of 0.39 (p < 0.003). In contrast, we observed a mean difference between final broach and implant version of −1.9° (+/− 3.5), with a range from −12.7° to 8.7° and a Spearman’s correlation coefficient of 0.89 (p < 0.001). In 83.6 % (46/55) final stem version was outside the normal range as defined by Tönnis (15-20°). The mean femoral neck resection height was 7.3 mm (+/− 5.6). There was no correlation between resection height and version of the implant (Spearman’s correlation coefficient 0.14). Conclusion Native femoral version significantly differs from the final anteversion of a cementless, straight, tapered stem and therefore is not a reliable reference in cementless THA. Measuring anteversion of the final “fit and fill” broach is a feasible assistance in order to predict final stem anteversion intraoperatively. There is no correlation between femoral neck resection height and version of the implant.
Collapse
Affiliation(s)
- Michael Worlicek
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany.
| | - Markus Weber
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Benjamin Craiovan
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Michael Wörner
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Florian Völlner
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Hans R Springorum
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Joachim Grifka
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Tobias Renkawitz
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| |
Collapse
|
25
|
Weber T, Dendorfer S, Bulstra SK, Grifka J, Verkerke GJ, Renkawitz T. Gait six month and one-year after computer assisted Femur First THR vs. conventional THR. Results of a patient- and observer- blinded randomized controlled trial. Gait Posture 2016; 49:418-425. [PMID: 27513739 DOI: 10.1016/j.gaitpost.2016.06.035] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2015] [Revised: 06/22/2016] [Accepted: 06/25/2016] [Indexed: 02/02/2023]
Abstract
A prospective randomized controlled trial is presented that is used to compare gait performance between the computer assisted Femur First (CAS FF) operation method and conventional THR (CON). 60 patients underwent a 3D gait analysis of the lower extremity at pre-operative, 6 months post-operative and twelve months post-operative. Detailed verification experiments were facilitated to ensure the quality of data as well as to avoid over-interpreting of the data. The results confirm a similar data-quality as reported in the literature. Walking speed, range of motion and symmetry thereof improved over the follow-up period, without significant differences between the groups. While all parameters do significantly increase over the follow-up period for both groups, there were no significant differences between them at any given time-point. Patients undergoing CAS FF showed a trend to improved hip flexion angle indicating a possible long-term benefit.
Collapse
Affiliation(s)
- Tim Weber
- Ostbayerische Technische Hochschule Regensburg, Faculty of Mechanical Engineering, Laboratory for Biomechanics, Regensburg, Germany; Regensburg University Medical Center (UKR), Department of Orthopaedic Surgery, Regensburg, Germany.
| | - Sebastian Dendorfer
- Ostbayerische Technische Hochschule Regensburg, Faculty of Mechanical Engineering, Laboratory for Biomechanics, Regensburg, Germany.
| | - Sjoerd K Bulstra
- University of Groningen, University Medical Center Groningen (UMCG), Department of Orthopaedic Surgery, Groningen, The Netherlands.
| | - Joachim Grifka
- Regensburg University Medical Center (UKR), Department of Orthopaedic Surgery, Regensburg, Germany.
| | - Gijsbertus J Verkerke
- University of Groningen, University Medical Center Groningen (UMCG), Department of Rehabilitation Medicine, Groningen, The Netherlands; University of Twente, Department of Biomechanical Engineering, Enschede, The Netherlands.
| | - Tobias Renkawitz
- Regensburg University Medical Center (UKR), Department of Orthopaedic Surgery, Regensburg, Germany.
| |
Collapse
|
26
|
Current standard rules of combined anteversion prevent prosthetic impingement but ignore osseous contact in total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2016; 40:2495-2504. [PMID: 27106215 DOI: 10.1007/s00264-016-3171-x] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Accepted: 03/10/2016] [Indexed: 12/27/2022]
Abstract
PURPOSE In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). METHODS Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. RESULTS Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p ≤ 0.001) and internal rotation (p ≤ 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p ≤0.034). CONCLUSION Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.
Collapse
|
27
|
Range of Hip Joint Motion in Developmental Dysplasia of the Hip Patients Following Total Hip Arthroplasty With the Surgical Technique Using the Concept of Combined Anteversion: A Study of Crowe I and II Patients. J Arthroplasty 2015; 30:2248-55. [PMID: 26228491 DOI: 10.1016/j.arth.2015.06.056] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Revised: 06/17/2015] [Accepted: 06/23/2015] [Indexed: 02/01/2023] Open
Abstract
The combined anteversion surgical technique has been proposed and used in clinical practice. To more objectively evaluate the feasibility of this surgical technique using combined anteversion concept for DDH patients, we studied 34 DDH patients (40 hips) in this research. Every patient underwent pelvic CT scans before and after surgery and the HHSs were recorded. Optimal range of joint motion was measured using a three-dimensional reconstruction technique and a dynamic measurement technique. The results revealed that joint function met the requirements of daily life and the range of motion was not over-limited by impingement between the prosthesis and the skeleton. Moreover, the combined anteversion was found to be the most critical parameter in this study.
Collapse
|
28
|
Does Computer-Assisted Femur First THR Improve Musculoskeletal Loading Conditions? BIOMED RESEARCH INTERNATIONAL 2015; 2015:625317. [PMID: 26582355 PMCID: PMC4637031 DOI: 10.1155/2015/625317] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/14/2014] [Revised: 11/15/2014] [Accepted: 11/26/2014] [Indexed: 12/28/2022]
Abstract
We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of “femur first/combined anteversion,” which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient's gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome.
Collapse
|
29
|
Tsai TY, Li JS, Dimitriou D, Kwon YM. Does component alignment affect gait symmetry in unilateral total hip arthroplasty patients? Clin Biomech (Bristol, Avon) 2015; 30:802-7. [PMID: 26117163 DOI: 10.1016/j.clinbiomech.2015.06.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Revised: 06/11/2015] [Accepted: 06/11/2015] [Indexed: 02/07/2023]
Abstract
BACKGROUND Component malposition in total hip arthroplasty patients has been associated with adverse clinical outcomes. However, whether the component alignment influences hip dynamic performance following total hip arthroplasty remains unclear. The purpose of this study was to investigate the relationship between the component alignment and in vivo hip kinematics during gait. METHODS Nineteen unilateral total hip arthroplasty patients received CT scan for creation of 3D hip models. The component alignment between the non-implanted and implanted hips were measured and compared. Three-dimensional hip kinematics for both hips of the total hip arthroplasty patients during gait was quantified using a dual fluoroscopic imaging technique. The differences between the implanted and non-implanted hip kinematics during gait were calculated. A forward stepwise multiple linear regression was performed to evaluate the relationships between the changes in implanted hip kinematics and the differences in component alignment with respect to the non-implanted hips. FINDINGS An average 5.1° (SD 6.5°; range -11.1° to 18.3°) increase in internal rotation was observed in the implanted hip than the contralateral non-implanted hip and significantly correlated with a linear combination of the increase of cup anteversion, cup medial translation and leg lengthening (R=0.81). INTERPRETATION Results suggested that the total hip arthroplasty patients compensated the changes in hip geometry by altering the dynamic movement during gait. Restoration of the native hip geometry, including acetabular cup anteversion, position and leg length could be one of the factors that influence the hip kinematics symmetry in total hip arthroplasty patients during gait.
Collapse
Affiliation(s)
- Tsung-Yuan Tsai
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Jing-Sheng Li
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Dimitris Dimitriou
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
| |
Collapse
|
30
|
Difference in Stem Alignment Between the Direct Anterior Approach and the Posterolateral Approach in Total Hip Arthroplasty. J Arthroplasty 2015; 30:1761-6. [PMID: 25956522 DOI: 10.1016/j.arth.2015.04.026] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Revised: 03/31/2015] [Accepted: 04/07/2015] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to investigate the effects of different surgical approaches, the posterolateral approach (PLA) and the direct anterior approach (DAA), on postoperative femoral anteversion and stem coronal and sagittal alignment in total hip arthroplasty (THA), and to identify the factors related to postoperative femoral anteversion and stem alignment. A total of 209 hips of 181 patients were evaluated. THA was performed through the PLA in 80 hips and through the DAA in 129 hips. Femoral anteversion and stem alignment were measured on postoperative computed tomography images. The factor related to postoperative anteversion change was preoperative femoral anteversion, and the surgical approaches did not affect the postoperative anteversion change, while surgical approach did have an effect on stem sagittal alignment.
Collapse
|
31
|
Renkawitz T, Weber M, Springorum HR, Sendtner E, Woerner M, Ulm K, Weber T, Grifka J. Impingement-free range of movement, acetabular component cover and early clinical results comparing ‘femur-first’ navigation and ‘conventional’ minimally invasive total hip arthroplasty. Bone Joint J 2015; 97-B:890-8. [DOI: 10.1302/0301-620x.97b7.34729] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated ‘femur-first’ total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated ‘femur-first’ group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups’ Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated ‘femur-first’ technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups. Cite this article: Bone Joint J 2015; 97-B:890–8.
Collapse
Affiliation(s)
- T. Renkawitz
- Regensburg University Medical Centre, Asklepios
Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077
Bad Abbach, Germany
| | - M. Weber
- Regensburg University Medical Centre, Asklepios
Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077
Bad Abbach, Germany
| | - H-R. Springorum
- Regensburg University Medical Centre, Asklepios
Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077
Bad Abbach, Germany
| | - E. Sendtner
- Regensburg University Medical Centre, Asklepios
Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077
Bad Abbach, Germany
| | - M. Woerner
- Regensburg University Medical Centre, Asklepios
Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077
Bad Abbach, Germany
| | - K. Ulm
- Technische Universität München, Institut
für Medizinische Statistik und Epidemiologie, Germany
| | - T. Weber
- Regensburg University Medical Centre, Asklepios
Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077
Bad Abbach, Germany
| | - J. Grifka
- Regensburg University Medical Centre, Asklepios
Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077
Bad Abbach, Germany
| |
Collapse
|
32
|
Tsai TY, Dimitriou D, Li JS, Kwon YM. Does haptic robot-assisted total hip arthroplasty better restore native acetabular and femoral anatomy? Int J Med Robot 2015; 12:288-95. [PMID: 25906764 DOI: 10.1002/rcs.1663] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Revised: 02/08/2015] [Accepted: 03/17/2015] [Indexed: 11/12/2022]
Abstract
BACKGROUND The objective was to evaluate whether total hip arthroplasty (THA) using haptic robot assistance restores hip geometry better than the free-hand technique. METHODS Twelve robot-assisted and 14 free-hand unilateral THA patients underwent CT scan for three-dimensional (3D) hip models. The anteversion, inclination and hip joint centre locations of the native and implanted hips in each patient were quantified and compared. RESULTS Significant increase of combined anteversion by 19.1 ± 11.7° and 23.5 ± 23.6° and decrease of cup inclination by 16.5 ± 6.0° and 10.2 ± 6.8° were observed in the robot-assisted and the free-hand THAs, respectively. Less variation in the difference of the component orientations (max 11.1 vs 18.3°) and the femoral head centre (max 4.5 vs 6.3 mm) were found in the robot-assisted group. CONCLUSION This study demonstrated that neither robot-assisted nor free-hand THAs had fully restored native hip geometry. However, the higher precision of the robot-assisted THA suggested that it has potential utility in restoring the native hip geometry. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Tsung-Yuan Tsai
- Department of Orthopedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Dimitris Dimitriou
- Department of Orthopedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Jing-Sheng Li
- Department of Orthopedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Young-Min Kwon
- Department of Orthopedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
33
|
Weber M, Lechler P, von Kunow F, Völlner F, Keshmiri A, Hapfelmeier A, Grifka J, Renkawitz T. The validity of a novel radiological method for measuring femoral stem version on anteroposterior radiographs of the hip after total hip arthroplasty. Bone Joint J 2015; 97-B:306-11. [DOI: 10.1302/0301-620x.97b3.34618] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Femoral stem version has a major influence on impingement and early post-operative stability after total hip arthroplasty (THA). The main objective of this study was to evaluate the validity of a novel radiological method for measuring stem version. Anteroposterior (AP) radiographs and three-dimensional CT scans were obtained for 115 patients (female/male 63/72, mean age 62.5 years (50 to 75)) who had undergone minimally invasive, cementless THA. Stem version was calculated from the AP hip radiograph by rotation-based change in the projected prosthetic neck–shaft (NSA*) angle using the mathematical formula ST = arcos [tan (NSA*) / tan (135)]. We used two independent observers who repeated the analysis after a six-week interval. Radiological measurements were compared with 3D-CT measurements by an independent, blinded external institute. We found a mean difference of 1.2° (sd 6.2) between radiological and 3D-CT measurements of stem version. The correlation between the mean radiological and 3D-CT stem torsion was r = 0.88 (p < 0.001). The intra- (intraclass correlation coefficient ≥ 0.94) and inter-observer agreement (mean concordance correlation coefficient = 0.87) for the radiological measurements were excellent. We found that femoral tilt was associated with the mean radiological measurement error (r = 0.22, p = 0.02). The projected neck–shaft angle is a reliable method for measuring stem version on AP radiographs of the hip after a THA. However, a highly standardised radiological technique is required for its precise measurement. Cite this article: Bone Joint J 2015; 97-B:306–11.
Collapse
Affiliation(s)
- M. Weber
- Regensburg University Medical Centre, Kaiser-Karl
V.-Allee 3, 93077 Bad Abbach, Germany
| | - P. Lechler
- University of Giessen and Marburg , Baldingerstraße, 35043
Marburg, Germany
| | - F. von Kunow
- Regensburg University Medical Centre, Kaiser-Karl
V.-Allee 3, 93077 Bad Abbach, Germany
| | - F. Völlner
- Regensburg University Medical Centre, Kaiser-Karl
V.-Allee 3, 93077 Bad Abbach, Germany
| | - A. Keshmiri
- Regensburg University Medical Centre, Kaiser-Karl
V.-Allee 3, 93077 Bad Abbach, Germany
| | - A. Hapfelmeier
- Technische Universität München, Ismaninger
Strasse 22, 81675 Munich, Germany
| | - J. Grifka
- Regensburg University Medical Centre, Kaiser-Karl
V.-Allee 3, 93077 Bad Abbach, Germany
| | - T. Renkawitz
- Regensburg University Medical Centre, Kaiser-Karl
V.-Allee 3, 93077 Bad Abbach, Germany
| |
Collapse
|
34
|
Tsai TY, Dimitriou D, Li G, Kwon YM. Does total hip arthroplasty restore native hip anatomy? three-dimensional reconstruction analysis. INTERNATIONAL ORTHOPAEDICS 2014; 38:1577-83. [PMID: 24966079 DOI: 10.1007/s00264-014-2401-3] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2014] [Accepted: 05/29/2014] [Indexed: 12/01/2022]
Abstract
PURPOSE Component orientations and positions in total hip arthroplasty (THA) are important parameters in restoring hip function. However, measurements using plain radiographs and 2D computed tomography (CT) slices are affected by patient position during imaging. This study used 3D CT to determine whether contemporary THA restores native hip geometry. METHODS Fourteen patients with unilateral THA underwent CT scan for 3D hip reconstruction. Hip models of the nonoperated side were mirrored with the implanted side to quantify the differences in hip geometry between sides. RESULTS The study demonstrated that combined hip anteversion (sum of acetabular and femoral anteversion) and vertical hip offset significantly increased by 25.3° ± 29.3° (range, -25.7° to 55.9°, p = 0.003) and 4.1 ± 4.7 mm (range, -7.1 to 9.8 mm, p = 0.009) in THAs. CONCLUSIONS These data suggest that hip anatomy is not fully restored following THA compared with the contralateral native hip.
Collapse
Affiliation(s)
- Tsung-Yuan Tsai
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital/Harvard Medical School, 55 Fruit St., GRJ-1215, Boston, MA, 02114, USA
| | | | | | | |
Collapse
|
35
|
Evaluation of range of motion restriction within the hip joint. Med Biol Eng Comput 2012; 51:467-77. [PMID: 23263850 PMCID: PMC3589629 DOI: 10.1007/s11517-012-1016-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2012] [Accepted: 12/13/2012] [Indexed: 11/24/2022]
Abstract
In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are at risk from impingement and those which are constrained due to soft tissue. Two experimental methodologies were used to determine motions which were limited by impingement and those motions which were limited by both impingement and soft tissue restraint. By comparing these two experimental results, motions which were limited by impingement were able to be separated from those motions which were limited by soft tissue restraint. The results show motions in extension as well as flexion combined with adduction are limited by soft tissue restraint. Motions in flexion, flexion combined with abduction and adduction are at risk from osseous impingement. Consequently, these motions represent where the maximum likely damage will occur in femoroacetabular impingement or at most risk of prosthetic impingement in total hip arthroplasty.
Collapse
|