Li Y, Wang N, Fan LF, Zhao PF, Li JH, Huang L, Wang ZY. Robust electrical impedance tomography for biological application: A mini review. Heliyon 2023; 9:e15195. [PMID: 37089335 PMCID: PMC10113865 DOI: 10.1016/j.heliyon.2023.e15195] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 03/10/2023] [Accepted: 03/29/2023] [Indexed: 04/05/2023] Open
Abstract
Electrical impedance tomography (EIT) has been used by researchers across several areas because of its low-cost and no-radiation properties. Researchers use complex conductivity in bioimpedance experiments to evaluate changes in various indicators within the image target. The diverse volumes and edges of biological tissues and the large impedance range impose dedicated demands on hardware design. The EIT hardware with a high signal-to-noise ratio (SNR), fast scanning and suitable for the impedance range of the image target is a fundamental foundation that EIT research needs to be equipped with. Understanding the characteristics of this technique and state-of-the-art design will accelerate the development of the robust system and provide a guidance for the superior performance of next-generation EIT. This review explores the hardware strategies for EIT proposed in the literature.
Collapse
|
2
|
Liu JZ, Li XB, Xiong H. A FPGA-based adaptive differential current source for electrical impedance tomography. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:094707. [PMID: 34598505 DOI: 10.1063/5.0062640] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 08/23/2021] [Indexed: 06/13/2023]
Abstract
A high output impedance current source with a wide bandwidth is needed in electrical impedance tomography systems. Limitations appear mainly at higher frequencies and non-simple loads. In order to adjust the output current, the amplitude and phase are made to achieve the expected value automatically. A current source based on the field programmable gate array is designed. In this paper, we proposed a double DAC differential current source structure. By measuring the voltage of the sampling resistor in series with the load and using the proposed dynamic reference point demodulation algorithm, the actual current amplitude and phase on the load can be quickly obtained. Through the adaptive compensation module, the output current is adjusted to the expected value. The experimental results show that the output resistance of the current source can reach 10 MΩ and the output capacitance can be less than 0.8 pF in the frequency range of 10 kHz-1.28 MHz. At the same time, the current amplitude attenuation is less than 0.016%, and the phase error is less than 0.0025° after compensation. Therefore, the proposed current source achieves widebands, biocompatibility, and high precision.
Collapse
Affiliation(s)
- J Z Liu
- The School of Control Science and Engineering, Tiangong University, Tianjin 300387, People's Republic of China
| | - X B Li
- The School of Control Science and Engineering, Tiangong University, Tianjin 300387, People's Republic of China
| | - H Xiong
- The School of Control Science and Engineering, Tiangong University, Tianjin 300387, People's Republic of China
| |
Collapse
|
3
|
Development of a Portable, Reliable and Low-Cost Electrical Impedance Tomography System Using an Embedded System. ELECTRONICS 2020. [DOI: 10.3390/electronics10010015] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Electrical impedance tomography (EIT) is a useful procedure with applications in industry and medicine, particularly in the lungs and brain area. In this paper, the development of a portable, reliable and low-cost EIT system for image reconstruction by using an embedded system (ES) is introduced herein. The novelty of this article is the hardware development of a complete low-cost EIT system, as well as three simple and efficient algorithms that can be implemented on ES. The proposed EIT system applies the adjacent voltage method, starting with an impedance acquisition stage that sends data to a Raspberry Pi 4 (RPi4) as ES. To perform the image reconstruction, a user interface was developed by using GNU Octave for RPi4 and the EIDORS library. A statistical analysis is performed to determine the best average value from the samples measured by using an analog-to-digital converter (ADC) with a capacity of 30 kSPS and 24-bit resolution. The tests for the proposed EIT system were performed using materials such as metal, glass and an orange to simulate its application in food industry. Experimental results show that the statistical median is more accurate with respect to the real voltage measurement; however, it represents a higher computational cost. Therefore, the mean is calculated and improved by discarding data values in a transitory state, achieving better accuracy than the median to determine the real voltage value, enhancing the quality of the reconstructed images. A performance comparison between a personal computer (PC) and RPi4 is presented. The proposed EIT system offers an excellent cost-benefit ratio with respect to a traditional PC, taking into account precision, accuracy, energy consumption, price, light weight, size, portability and reliability. The proposed EIT system has potential application in mechanical ventilation, food industry and structural health monitoring.
Collapse
|
4
|
Tomicic V, Cornejo R. Lung monitoring with electrical impedance tomography: technical considerations and clinical applications. J Thorac Dis 2019; 11:3122-3135. [PMID: 31463141 DOI: 10.21037/jtd.2019.06.27] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
In recent years there has been substantial progress in the imaging evaluation of patients with lung disease requiring mechanical ventilatory assistance. This has been demonstrated by the inclusion of pulmonary ultrasound, positron emission tomography, electrical impedance tomography (EIT), and magnetic resonance imaging (MRI). The EIT uses electric current to evaluate the distribution of alternating current conductivity within the thoracic cavity. The advantage of the latter is that it is non-invasive, bedside radiation-free functional imaging modality for continuous monitoring of lung ventilation and perfusion. EIT can detect recruitment or derecruitment, overdistension, variation of poorly ventilated lung units (silent spaces), and pendelluft phenomenon in spontaneously breathing patients. In addition, the regional expiratory time constants have been recently explored.
Collapse
Affiliation(s)
- Vinko Tomicic
- Jefe Unidad de Cuidados Intensivos Respiratorios, Clínica Indisa, Universidad Andres Bello, Santiago, Chile
| | - Rodrigo Cornejo
- Jefe Unidad de Pacientes Críticos, Departamento de Medicina, Hospital Clínico Universidad de Chile, Chile
| |
Collapse
|
5
|
FPGA Implementation of ECT Digital System for Imaging Conductive Materials. ALGORITHMS 2019. [DOI: 10.3390/a12020028] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This paper presents the hardware implementation of a stand-alone Electrical Capacitance Tomography (ECT) system employing a Field Programmable Gate Array (FPGA). The image reconstruction algorithms of the ECT system demand intensive computation and fast processing of large number of measurements. The inner product of large vectors is the core of the majority of these algorithms. Therefore, a reconfigurable segmented parallel inner product architecture for the parallel matrix multiplication is proposed. In addition, hardware-software codesign targeting FPGA System-On-Chip (SoC) is applied to achieve high performance. The development of the hardware-software codesign is carried out via commercial tools to adjust the software algorithms and parameters of the system. The ECT system is used in this work to monitor the characteristic of the molten metal in the Lost Foam Casting (LFC) process. The hardware system consists of capacitive sensors, wireless nodes and FPGA module. The experimental results reveal high stability and accuracy when building the ECT system based on the FPGA architecture. The proposed system achieves high performance in terms of speed and small design density.
Collapse
|
6
|
Aguiar Santos S, Czaplik M, Orschulik J, Hochhausen N, Leonhardt S. Lung pathologies analyzed with multi-frequency electrical impedance tomography: Pilot animal study. Respir Physiol Neurobiol 2018; 254:1-9. [DOI: 10.1016/j.resp.2018.03.016] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Revised: 03/13/2018] [Accepted: 03/30/2018] [Indexed: 11/26/2022]
|
7
|
Han B, Xu Y, Dong F. Design of current source for multi-frequency simultaneous electrical impedance tomography. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:094709. [PMID: 28964244 DOI: 10.1063/1.5004185] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 09/11/2017] [Indexed: 06/07/2023]
Abstract
Multi-frequency electrical impedance tomography has been evolving from the frequency-sweep approach to the multi-frequency simultaneous measurement technique which can reduce measuring time and will be increasingly attractive for time-varying biological applications. The accuracy and stability of the current source are the key factors determining the quality of the image reconstruction. This article presents a field programmable gate array-based current source for a multi-frequency simultaneous electrical impedance tomography system. A novel current source circuit was realized by combining the classic current mirror based on the feedback amplifier AD844 with a differential topology. The optimal phase offsets of harmonic sinusoids were obtained through the crest factor analysis. The output characteristics of this current source were evaluated by simulation and actual measurement. The results include the following: (1) the output impedance was compared with one of the Howland pump circuit in simulation, showing comparable performance at low frequencies. However, the proposed current source makes lower demands for resistor tolerance but performs even better at high frequencies. (2) The output impedance in actual measurement below 200 kHz is above 1.3 MΩ and can reach 250 KΩ up to 1 MHz. (3) An experiment based on a biological RC model has been implemented. The mean error for the demodulated impedance amplitude and phase are 0.192% and 0.139°, respectively. Therefore, the proposed current source is wideband, biocompatible, and high precision, which demonstrates great potential to work as a sub-system in the multi-frequency electrical impedance tomography system.
Collapse
Affiliation(s)
- Bing Han
- Tianjin Key Laboratory of Process Measurement and Control, School of Electrical and Information Engineering, Tianjin University, Tianjin, People's Republic of China
| | - Yanbin Xu
- Tianjin Key Laboratory of Process Measurement and Control, School of Electrical and Information Engineering, Tianjin University, Tianjin, People's Republic of China
| | - Feng Dong
- Tianjin Key Laboratory of Process Measurement and Control, School of Electrical and Information Engineering, Tianjin University, Tianjin, People's Republic of China
| |
Collapse
|
8
|
Orschulik J, Petkau R, Wartzek T, Hochhausen N, Czaplik M, Leonhardt S, Teichmann D. Improved electrode positions for local impedance measurements in the lung-a simulation study. Physiol Meas 2016; 37:2111-2129. [PMID: 27811407 DOI: 10.1088/0967-3334/37/12/2111] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Impedance spectroscopy can be used to analyze the dielectric properties of various materials. In the biomedical domain, it is used as bioimpedance spectroscopy (BIS) to analyze the composition of body tissue. Being a non-invasive, real-time capable technique, it is a promising modality, especially in the field of lung monitoring. Unfortunately, up to now, BIS does not provide any regional lung information as the electrodes are usually placed in hand-to-hand or transthoracic configurations. Even though transthoracic electrode configurations are in general capable of monitoring the lung, no focusing to specific regions is achieved. In order to resolve this issue, we use a finite element model (FEM) of the human body to study the effect of different electrode configurations on measured BIS data. We present evaluation results and show suitable electrode configurations for eight lung regions. We show that, using these optimized configurations, BIS measurements can be focused to desired regions allowing local lung analysis.
Collapse
Affiliation(s)
- Jakob Orschulik
- Philips Chair for Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | | | | | | | | | | | | |
Collapse
|
9
|
System Description and First Application of an FPGA-Based Simultaneous Multi-Frequency Electrical Impedance Tomography. SENSORS 2016; 16:s16081158. [PMID: 27463715 PMCID: PMC5017324 DOI: 10.3390/s16081158] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 06/02/2016] [Accepted: 07/21/2016] [Indexed: 11/16/2022]
Abstract
A new prototype of a multi-frequency electrical impedance tomography system is presented. The system uses a field-programmable gate array as a main controller and is configured to measure at different frequencies simultaneously through a composite waveform. Both real and imaginary components of the data are computed for each frequency and sent to the personal computer over an ethernet connection, where both time-difference imaging and frequency-difference imaging are reconstructed and visualized. The system has been tested for both time-difference and frequency-difference imaging for diverse sets of frequency pairs in a resistive/capacitive test unit and in self-experiments. To our knowledge, this is the first work that shows preliminary frequency-difference images of in-vivo experiments. Results of time-difference imaging were compared with simulation results and shown that the new prototype performs well at all frequencies in the tested range of 60 kHz-960 kHz. For frequency-difference images, further development of algorithms and an improved normalization process is required to correctly reconstruct and interpreted the resulting images.
Collapse
|
10
|
Saied I, Meribout M. Electronic hardware design of electrical capacitance tomography systems. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2016; 374:rsta.2015.0331. [PMID: 27185964 DOI: 10.1098/rsta.2015.0331] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 02/22/2016] [Indexed: 06/05/2023]
Abstract
Electrical tomography techniques for process imaging are very prominent for industrial applications, such as the oil and gas industry and chemical refineries, owing to their ability to provide the flow regime of a flowing fluid within a relatively high throughput. Among the various techniques, electrical capacitance tomography (ECT) is gaining popularity due to its non-invasive nature and its capability to differentiate between different phases based on their permittivity distribution. In recent years, several hardware designs have been provided for ECT systems that have improved its resolution of measurements to be around attofarads (aF, 10(-18) F), or the number of channels, that is required to be large for some applications that require a significant amount of data. In terms of image acquisition time, some recent systems could achieve a throughput of a few hundred frames per second, while data processing time could be achieved in only a few milliseconds per frame. This paper outlines the concept and main features of the most recent front-end and back-end electronic circuits dedicated for ECT systems. In this paper, multiple-excitation capacitance polling, a front-end electronic technique, shows promising results for ECT systems to acquire fast data acquisition speeds. A highly parallel field-programmable gate array (FPGA) based architecture for a fast reconstruction algorithm is also described. This article is part of the themed issue 'Supersensing through industrial process tomography'.
Collapse
Affiliation(s)
- I Saied
- Department of Electrical Engineering, Petroleum Institute, Abu Dhabi, United Arab Emirates
| | - M Meribout
- Department of Electrical Engineering, Petroleum Institute, Abu Dhabi, United Arab Emirates
| |
Collapse
|