1
|
Nekooeian M, Roozbeh J, Ezzatzadegan Jahromi S, Moaref A, Masjedi F. The superiority of bioimpedance vs. echocardiography and pitting edema in predicting automated office blood pressure in continuous ambulatory peritoneal dialysis patients. Ther Apher Dial 2024; 28:272-283. [PMID: 37850431 DOI: 10.1111/1744-9987.14074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 09/22/2023] [Accepted: 10/09/2023] [Indexed: 10/19/2023]
Abstract
INTRODUCTION To achieve optimal blood pressure control in continuous ambulatory peritoneal dialysis (CAPD) patients, identifying methods of volume assessment with the strongest correlation with blood pressure is essential. METHODS In this cross-sectional study, 52 CAPD patients were assigned to automated office blood pressure (AOBP) measurement, assessment of pedal pitting edema, bioimpedance analysis (BIA), and inferior vena cava collapsibility index (IVCCI%) measurement. Data were analyzed using STATA ver.17, and the significance level was p < 0.05. RESULTS Fifty-two patients were divided based on their AOBP readings. 29 (55.8%) of patients had uncontrolled AOBP. Overhydration (OH) and the grade of pitting edema were significantly higher in the uncontrolled AOBP group. OH was identified as the best variable for predicting blood pressure (p ≤ 0.001) and detecting uncontrolled blood pressure (AUC = 0.832) using multivariate linear regression and ROC analysis, respectively. CONCLUSION BIA-derived OH was the best variable for predicting systolic and diastolic AOBP, outperforming IVCCI% and pitting edema.
Collapse
Affiliation(s)
- Mohammad Nekooeian
- Shiraz Nephro-Urology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Jamshid Roozbeh
- Shiraz Nephro-Urology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Shahrokh Ezzatzadegan Jahromi
- Shiraz Nephro-Urology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
- Department of Internal Medicine, School of Medicine, Shiraz University of Medical Science, Shiraz, Iran
| | - Alireza Moaref
- Department of Cardiology, School of Medicine, Shiraz University of Medical Science, Shiraz, Iran
- Cardiovascular Research Center, Shiraz University of Medical Science, Shiraz, Iran
| | - Fatemeh Masjedi
- Shiraz Nephro-Urology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
2
|
Tian N, Yang X, Guo Q, Zhou Q, Yi C, Lin J, Cao P, Ye H, Chen M, Yu X. Bioimpedance Guided Fluid Management in Peritoneal Dialysis: A Randomized Controlled Trial. Clin J Am Soc Nephrol 2021; 15:685-694. [PMID: 32349977 PMCID: PMC7269207 DOI: 10.2215/cjn.06480619] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2019] [Accepted: 03/26/2020] [Indexed: 01/20/2023]
Abstract
BACKGROUND AND OBJECTIVES Bioelectrical impedance analysis (BIA) devices can help assess volume overload in patients receiving maintenance peritoneal dialysis. However, the effects of BIA on the short-term hard end points of peritoneal dialysis lack consistency. This study aimed to test whether BIA-guided fluid management could improve short-term outcomes in patients on peritoneal dialysis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS A single-center, open-labeled, randomized, controlled trial was conducted. Patients on prevalent peritoneal dialysis with volume overload were recruited from July 1, 2013 to March 30, 2014 and followed for 1 year in the initial protocol. All participants with volume overload were 1:1 randomized to the BIA-guided arm (BIA and traditional clinical methods) and control arm (only traditional clinical methods). The primary end point was all-cause mortality and secondary end points were cardiovascular disease mortality and technique survival. RESULTS A total of 240 patients (mean age, 49 years; men, 51%; diabetic, 21%, 120 per group) were enrolled. After 1-year follow-up, 11(5%) patients died (three in BIA versus eight in control) and 21 patients were permanently transferred to hemodialysis (eight in BIA versus 13 in control). The rate of extracellular water/total body water decline in the BIA group was significantly higher than that in the control group. The 1-year patient survival rates were 96% and 92% in BIA and control groups, respectively. No significant statistical differences were found between patients randomized to the BIA-guided or control arm in terms of patient survival, cardiovascular disease mortality, and technique survival (P>0.05). CONCLUSIONS Although BIA-guided fluid management improved the fluid overload status better than the traditional clinical method, no significant effect was found on 1-year patient survival and technique survival in patients on peritoneal dialysis.
Collapse
Affiliation(s)
- Na Tian
- Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.,Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China.,Department of Nephrology, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, China
| | - Xiao Yang
- Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.,Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China
| | - Qunying Guo
- Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.,Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China
| | - Qian Zhou
- Department of Medical Statistics, Clinical Trials Unit, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China
| | - Chunyan Yi
- Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.,Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China
| | - Jianxiong Lin
- Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.,Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China
| | - Peiyi Cao
- Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.,Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China
| | - Hongjian Ye
- Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.,Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China
| | - Menghua Chen
- Department of Nephrology, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, China
| | - Xueqing Yu
- Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China .,Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China.,Department of Nephrology, Guangdong Provincial People's Hospital, Guangzhou, Guangdong, China
| |
Collapse
|
3
|
Schwaiger E, Simon A, Wabel P, Schairer B, Berner C, Signorini L, Ernstbrunner M, Evstatiev R, Schwabl P, Hinterholzer G, Frommlet F, Vychytil A, Müller CJ, Hecking M. Bioimpedance spectroscopy for fluid status assessment in patients with decompensated liver cirrhosis: Implications for peritoneal dialysis. Sci Rep 2020; 10:2869. [PMID: 32071351 PMCID: PMC7028989 DOI: 10.1038/s41598-020-59817-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 01/31/2020] [Indexed: 01/08/2023] Open
Abstract
Bioimpedance spectroscopy (BIS) is routinely used in peritoneal dialysis patients and might aid fluid status assessment in patients with liver cirrhosis, but the effect of ascites volume removal on BIS-readings is unknown. Here we determined changes in BIS-derived parameters and clinical signs of fluid overload from before to after abdominal paracentesis. Per our pre-specified sample size calculation, we studied 31 cirrhotic patients, analyzing demographics, labs and clinical parameters along with BIS results. Mean volume of the abdominal paracentesis was 7.8 ± 2.6 L. From pre-to post-paracentesis, extracellular volume (ECV) decreased (20.2 ± 5.2 L to 19.0 ± 4.8 L), total body volume decreased (39.8 ± 9.8 L to 37.8 ± 8.5 L) and adipose tissue mass decreased (38.4 ± 16.0 kg to 29.9 ± 12.9 kg; all p < 0.002). Correlation of BIS-derived parameters from pre to post-paracentesis ranged from R² = 0.26 for body cell mass to R² = 0.99 for ECV. Edema did not correlate with BIS-derived fluid overload (FO ≥ 15% ECV), which occurred in 16 patients (51.6%). In conclusion, BIS-derived information on fluid status did not coincide with clinical judgement. The changes in adipose tissue mass support the BIS-model assumption that fluid in the peritoneal cavity is not detectable, suggesting that ascites (or peritoneal dialysis fluid) mass should be subtracted from adipose tissue if BIS is used in patients with a full peritoneal cavity.
Collapse
Affiliation(s)
- Elisabeth Schwaiger
- Department of Internal Medicine III, Clinical Division of Nephrology and Dialysis, Medical University of Vienna, Vienna, Austria.,Department of Internal Medicine II, Kepler University Hospital, Med Campus III, Linz, Austria
| | - Amrei Simon
- Department of Internal Medicine III, Clinical Division of Nephrology and Dialysis, Medical University of Vienna, Vienna, Austria
| | - Peter Wabel
- Fresenius Medical Care, Research and Development, Bad Homburg, Germany
| | - Benjamin Schairer
- Department of Internal Medicine III, Clinical Division of Nephrology and Dialysis, Medical University of Vienna, Vienna, Austria
| | - Carolin Berner
- 1st Medical Department, Division for Nephrology, Sozialmedizinisches Zentrum Süd, Vienna, Austria
| | - Lorenzo Signorini
- Dipartimento di Nefrologia e Dialis, Azienda Ospedaliera Universitaria Integrata, Verona, Italy
| | - Matthäus Ernstbrunner
- Department of Anaesthesiology and Critical Care Medicine, Medical University of Vienna, Vienna, Austria
| | - Rayko Evstatiev
- Department of Internal Medicine III, Clinical Division of Gastroenterology and Hepatology, Medical University of Vienna, Vienna, Austria
| | - Philipp Schwabl
- Department of Internal Medicine III, Clinical Division of Gastroenterology and Hepatology, Medical University of Vienna, Vienna, Austria
| | - Georg Hinterholzer
- 1st Medical Department, Division for Nephrology, Sozialmedizinisches Zentrum Süd, Vienna, Austria
| | - Florian Frommlet
- Center for Medical Statistics, Informatics and Intelligent Systems, Medical University of Vienna, Vienna, Austria
| | - Andreas Vychytil
- Department of Internal Medicine III, Clinical Division of Nephrology and Dialysis, Medical University of Vienna, Vienna, Austria
| | - Christian J Müller
- Department of Internal Medicine III, Clinical Division of Gastroenterology and Hepatology, Medical University of Vienna, Vienna, Austria
| | - Manfred Hecking
- Department of Internal Medicine III, Clinical Division of Nephrology and Dialysis, Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
4
|
Oh KH, Baek SH, Joo KW, Kim DK, Kim YS, Kim S, Oh YK, Han BG, Chang JH, Chung W, Na KY. Does Routine Bioimpedance-Guided Fluid Management Provide Additional Benefit to Non-Anuric Peritoneal Dialysis Patients? Results from COMPASS Clinical Trial. Perit Dial Int 2018; 38:131-138. [PMID: 29386302 DOI: 10.3747/pdi.2016.00241] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Accepted: 10/22/2017] [Indexed: 01/29/2023] Open
Abstract
INTRODUCTION In peritoneal dialysis (PD) patients, volume overload is related to cardiac dysfunction and mortality, while intravascular volume depletion is associated with a rapid decline in the residual renal function (RRF). This study sought to determine the clinical usefulness of bioimpedance spectroscopy (BIS)-guided fluid management for preserving RRF and cardiac function in PD patients. SUBJECTS AND METHODS This is a multicenter, prospective, open-label study that was conducted over a 1-year period (NCT01887262). Non-anuric (urine volume > 500 mL/day) subjects on PD were enrolled. Subjects in the control group received fluid management based on the clinical information alone. Those in the BIS group received BIS-guided fluid management along with clinical information. RESULTS The subjects (N = 137, mean age 51.3 ± 12.8 years, 54% male) were randomly assigned to the BIS group (n = 67) or to the control group (n = 70). There were no significant differences between the 2 groups with regard to age, sex ratio, cause of kidney failure, duration of PD, baseline comorbidity, RRF, PD method, or peritoneal transport type. At baseline, the 2 groups were not different in terms of RRF (glomerular filtration rate [GFR], 5.1 ± 2.9 vs 5.5 ± 3.7 mL/min/1.73 m2). After follow-up, changes in the GFR between the 2 groups were not different (-1.5 ± 2.4 vs -1.3 ± 2.6 mL/min/1.73 m2, p = 0.593). Over the 1-year study period, both groups maintained stability of various fluid status parameters. Between the 2 groups, there were no differences in the net change of various fluid status parameters such as overhydration (OH) and extracellular water/total body water (ECW/TBW). A net change in ECW over 1 year was slightly but significantly higher in the control group (net increase, 0.57 ± 1.27 vs 0.05 ± 1.63 L, p = 0.047). However, this difference was not translated into an improvement in RRF in the BIS group. There were no differences in echocardiographic parameters or arterial stiffness at the end of follow-up. CONCLUSION Routine BIS-guided fluid management in non-anuric PD patients did not provide additional benefit in volume control, RRF preservation, or cardiovascular (CV) parameters. However, our study cannot be generalized to the whole PD population. Further research is warranted in order to investigate the subpopulation of PD patients who may benefit from routine BIS-guided fluid management.
Collapse
Affiliation(s)
- Kook-Hwan Oh
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Seon Ha Baek
- Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Gyeonggi Do, Korea
| | - Kwon-Wook Joo
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Dong Ki Kim
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Yon Su Kim
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Sejoong Kim
- Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Gyeonggi Do, Korea
| | - Yun Kyu Oh
- Department of Internal Medicine, Seoul National University Boramae Medical Center, Seoul, Korea
| | - Byoung Geun Han
- Department of Internal Medicine, Wonju Severance Christian Hospital, Wonju, Korea
| | - Jae Hyun Chang
- Department of Internal Medicine, Gachon University Gil Hospital, Incheon, Korea
| | - Wookyung Chung
- Department of Internal Medicine, Gachon University Gil Hospital, Incheon, Korea
| | - Ki Young Na
- Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Gyeonggi Do, Korea
| | | |
Collapse
|
5
|
Scotland G, Cruickshank M, Jacobsen E, Cooper D, Fraser C, Shimonovich M, Marks A, Brazzelli M. Multiple-frequency bioimpedance devices for fluid management in people with chronic kidney disease receiving dialysis: a systematic review and economic evaluation. Health Technol Assess 2018; 22:1-138. [PMID: 29298736 PMCID: PMC5776406 DOI: 10.3310/hta22010] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Chronic kidney disease (CKD) is a long-term condition requiring treatment such as conservative management, kidney transplantation or dialysis. To optimise the volume of fluid removed during dialysis (to avoid underhydration or overhydration), people are assigned a 'target weight', which is commonly assessed using clinical methods, such as weight gain between dialysis sessions, pre- and post-dialysis blood pressure and patient-reported symptoms. However, these methods are not precise, and measurement devices based on bioimpedance technology are increasingly used in dialysis centres. Current evidence on the role of bioimpedance devices for fluid management in people with CKD receiving dialysis is limited. OBJECTIVES To evaluate the clinical effectiveness and cost-effectiveness of multiple-frequency bioimpedance devices versus standard clinical assessment for fluid management in people with CKD receiving dialysis. DATA SOURCES We searched major electronic databases [e.g. MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, EMBASE, Science Citation Index and Cochrane Central Register of Controlled Trials (CENTRAL)] conference abstracts and ongoing studies. There were no date restrictions. Searches were undertaken between June and October 2016. REVIEW METHODS Evidence was considered from randomised controlled trials (RCTs) comparing fluid management by multiple-frequency bioimpedance devices and standard clinical assessment in people receiving dialysis, and non-randomised studies evaluating the use of the devices for fluid management in people receiving dialysis. One reviewer extracted data and assessed the risk of bias of included studies. A second reviewer cross-checked the extracted data. Standard meta-analyses techniques were used to combine results from included studies. A Markov model was developed to assess the cost-effectiveness of the interventions. RESULTS Five RCTs (with 904 adult participants) and eight non-randomised studies (with 4915 adult participants) assessing the use of the Body Composition Monitor [(BCM) Fresenius Medical Care, Bad Homburg vor der Höhe, Germany] were included. Both absolute overhydration and relative overhydration were significantly lower in patients evaluated using BCM measurements than for those evaluated using standard clinical methods [weighted mean difference -0.44, 95% confidence interval (CI) -0.72 to -0.15, p = 0.003, I2 = 49%; and weighted mean difference -1.84, 95% CI -3.65 to -0.03; p = 0.05, I2 = 52%, respectively]. Pooled effects of bioimpedance monitoring on systolic blood pressure (SBP) (mean difference -2.46 mmHg, 95% CI -5.07 to 0.15 mmHg; p = 0.06, I2 = 0%), arterial stiffness (mean difference -1.18, 95% CI -3.14 to 0.78; p = 0.24, I2 = 92%) and mortality (hazard ratio = 0.689, 95% CI 0.23 to 2.08; p = 0.51) were not statistically significant. The economic evaluation showed that, when dialysis costs were included in the model, the probability of bioimpedance monitoring being cost-effective ranged from 13% to 26% at a willingness-to-pay threshold of £20,000 per quality-adjusted life-year gained. With dialysis costs excluded, the corresponding probabilities of cost-effectiveness ranged from 61% to 67%. LIMITATIONS Lack of evidence on clinically relevant outcomes, children receiving dialysis, and any multifrequency bioimpedance devices, other than the BCM. CONCLUSIONS BCM used in addition to clinical assessment may lower overhydration and potentially improve intermediate outcomes, such as SBP, but effects on mortality have not been demonstrated. If dialysis costs are not considered, the incremental cost-effectiveness ratio falls below £20,000, with modest effects on mortality and/or hospitalisation rates. The current findings are not generalisable to paediatric populations nor across other multifrequency bioimpedance devices. FUTURE WORK Services that routinely use the BCM should report clinically relevant intermediate and long-term outcomes before and after introduction of the device to extend the current evidence base. STUDY REGISTRATION This study is registered as PROSPERO CRD42016041785. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Graham Scotland
- Health Economics Research Unit, University of Aberdeen, Aberdeen, UK
| | | | - Elisabet Jacobsen
- Health Economics Research Unit, University of Aberdeen, Aberdeen, UK
| | - David Cooper
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | - Cynthia Fraser
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | | | | | - Miriam Brazzelli
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| |
Collapse
|
6
|
Oei E, Paudel K, Visser A, Finney H, Fan SL. Is overhydration in peritoneal dialysis patients associated with cardiac mortality that might be reversible? World J Nephrol 2016; 5:448-454. [PMID: 27648408 PMCID: PMC5011251 DOI: 10.5527/wjn.v5.i5.448] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 05/02/2016] [Accepted: 07/13/2016] [Indexed: 02/06/2023] Open
Abstract
AIM To study the relationship between overhydration (OH) in peritoneal dialysis (PD) patients and cardiac mortality.
METHODS OH, as measured by body composition monitor (BCM), is associated with increased mortality in dialysis patients. BCM has been used to guide treatment on the assumption that correcting OH will improve cardiac morbidity and mortality although data demonstrating causality that is reversible is limited. We wished to determine if OH in PD patients predicted cardiac mortality, and if there was a correlation between OH and cardiac troponin-T (cTnT) levels. Finally, we wished to determine if improving OH values would lead to a decrement in cTnT. All prevalent PD patients over the study period of 57 mo who had contemporaneous BCM and cTnT measurements were followed irrespective of transplantation or PD technique failure. We also studied a cohort of patients with who had severe OH (> +2L). The Fresenius Body Composition Monitor was used to obtain hydration parameters. cTnT levels were done as part of routine clinical care. Data was analysed using SPSS version 20.0.
RESULTS There were 48 deaths in the 336 patients. The patients that died from cardiac or non-cardiac causes were similar with respect to their age, incidence of diabetes mellitus, gender, ethnicity and cause of renal failure. However, the patients with cardiac causes of death had significantly shorter dialysis vintage (10.3 mo vs 37.0 mo, P < 0.0001) and were significantly more overhydrated by BCM measurement (2.95 L vs 1.35 L, P < 0.05). The mean (standard error of the means) hydration status of the 336 patients was +1.15 (0.12) L and the median [interquartile range (IQR)] cTnT level was 43.5 (20-90) ng/L. The cTnT results were not normally distributed and were therefore transformed logarithmically. There was a statistically significant correlation between Log (cTnT) with the OH value (Spearman r value 0.425, P < 0.0001). We identified a sub-group of patients that were severely overhydrated; median (IQR) hydration at baseline was +2.7 (2.3 to 3.7) L. They were followed up for a minimum of 6 mo. Reduction in OH values in these patients over 6 mo correlated with lowering of cTnT levels (Spearman r value 0.29, P < 0.02).
CONCLUSION Patients that were overhydrated had higher cTnT, and had deaths that were more likely to be cardiac related. Reduction in OH correlated with lowering of cTnT.
Collapse
|