Iordanou S, Papathanassoglou E, Middleton N, Palazis L, Timiliotou-Matsentidou C, Raftopoulos V. Device-associated health care-associated infections: The effectiveness of a 3-year prevention and control program in the Republic of Cyprus.
Nurs Crit Care 2020;
27:602-611. [PMID:
33314424 DOI:
10.1111/nicc.12581]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 11/27/2020] [Accepted: 11/30/2020] [Indexed: 01/04/2023]
Abstract
BACKGROUND
Device-associated health care-associated infections (DA-HAIs) are a major threat to patient safety, particularly in the Intensive Care Unit (ICU). This study aimed to evaluate the effectiveness of a bundle of infection control measures to reduce DA-HAIs in the ICU of a General Hospital in the Republic of Cyprus, over a 3-year period.
METHODS
We studied 599 ICU patients with a length of stay (LOS) for at least 48 hours. Our prospective cohort study was divided into three surveillance phases. Ventilator-associated pneumonia (VAP), central line-associated blood-stream infections (CLABSI), and catheter-associated blood-stream infections (CAUTI) incidence rates, LOS, and mortality were calculated before, during, and after the infection prevention and control programme.
RESULTS
There was a statistically significant reduction in the number of DA-HAI events during the surveillance periods, associated with DA-HAIs prevention efforts. In 2015 (prior to programme implementation), the baseline DA-HAIs instances were 43: 16 VAP (10.1/1000 Device Days), 21 (15.9/1000DD) CLABSIs, and 6 (2.66/1000DD) CAUTIs, (n = 198). During the second phase (2016), CLABSIs prevention measures were implemented and the number of infections were 24: 14 VAP (12.21/1000DD), 4 (4.2/1000DD) CLABSIs, and 6 (3.22/1000DD) CAUTIs, (n = 184). During the third phase (2017), VAP and CAUTI prevention measures were again implemented and the rates were 6: (3 VAP: 12.21/1000DD), 2 (1.95/1000DD) CLABSIs, and 1 (0.41/1000DD) CAUTIs, (n = 217). There was an overall reduction of 87% in the total number of DA-HAIs instances for the period 1 January 2015 to 31 December 2017.
CONCLUSIONS
The significant overall reduction in DA-HAI rates indicates that a comprehensive infection control programme can affect DA-HAI rates.