Woittiez KJ, Woittiez AJJ. Fatal endotracheal tube obstruction due to the ball valve effect.
BMJ Case Rep 2015;
2015:bcr-2014-208189. [PMID:
25618886 DOI:
10.1136/bcr-2014-208189]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
In patients suffering from pulmonary haemorrhage, or in patients who recently received a tracheostomy, acute occlusion of the endotracheal tube due to a blood clot is a rare, but well-known complication. Acute and complete occlusion of the tube is easily recognisable. There are various methods of removing the obstructive clot, such as using a bronchoscope with forceps, topical thrombolysis, saline lavage and suctioning. There are no guidelines concerning preventive routine bronchoscopic lavage. When there is a partial obstruction of the endotracheal tube, ventilation is possible, although high inspiratory pressures are necessary. If the clot functions as a ball valve ventil, raised intrathoracic pressure will cause right-sided heart failure or tension pneumothorax. It is important to recognise a partially obstructed tube in time and remove the obstruction.
Collapse