1
|
Lall R, Lee K, Chopra S, Kandala A, Evans M, Seo Y, Niknejad A, Anwar M. Low cost, high temporal resolution optical fiber-based γ-photon sensor for real-time pre-clinical evaluation of cancer-targeting radiopharmaceuticals. Biosens Bioelectron 2024; 247:115956. [PMID: 38145595 DOI: 10.1016/j.bios.2023.115956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 12/17/2023] [Accepted: 12/20/2023] [Indexed: 12/27/2023]
Abstract
Cancer radiopharmaceutical therapies (RPTs) have demonstrated great promise in the treatment of neuroendocrine and prostate cancer, giving hope to late-stage metastatic cancer patients with currently very few treatment options. These therapies have sparked a large amount of interest in pre-clinical research due to their ability to target metastatic disease, with many research efforts focused towards developing and evaluating targeted RPTs for different cancer types in in vivo models. Here we describe a method for monitoring real-time in vivo binding kinetics for the pre-clinical evaluation of cancer RPTs. Recognizing the significant heterogeneity in biodistribution of RPTs among even genetically identical animal models, this approach offers long-term monitoring of the same in vivo organism without euthanasia in contrast to ex vivo tissue dosimetry, while providing high temporal resolution with a low-cost, easily assembled platform, that is not present in small-animal SPECT/CTs. The method utilizes the developed optical fiber-based γ-photon biosensor, characterized to have a wide linear dynamic range with Lutetium-177 (177Lu) activity (0.5-500 μCi/mL), a common radioisotope used in cancer RPT. The probe's ability to track in vivo uptake relative to SPECT/CT and ex vivo dosimetry techniques was verified by administering 177Lu-PSMA-617 to mouse models bearing human prostate cancer tumors (PC3-PIP, PC3-flu). With this method for monitoring RPT uptake, it is possible to evaluate changes in tissue uptake at temporal resolutions <1 min to determine RPT biodistribution in pre-clinical models and better understand dose relationships with tumor ablation, toxicity, and recurrence when attempting to move therapies towards clinical trial validation.
Collapse
Affiliation(s)
- Rahul Lall
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, Berkeley, CA, 94720, USA.
| | - Kyoungtae Lee
- Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA, 94107, USA
| | - Shalini Chopra
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, 94107, USA
| | - Averal Kandala
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, Berkeley, CA, 94720, USA
| | - Michael Evans
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, 94107, USA
| | - Youngho Seo
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, 94107, USA
| | - Ali Niknejad
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, Berkeley, CA, 94720, USA
| | - Mekhail Anwar
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, Berkeley, CA, 94720, USA; Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA, 94107, USA
| |
Collapse
|
2
|
Investigation of the light output of 3D-printed plastic scintillators for dosimetry applications. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2022.106864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
3
|
Ding L, Wu Q, Wang Q, Li Y, Perks RM, Zhao L. Advances on inorganic scintillator-based optic fiber dosimeters. EJNMMI Phys 2020; 7:60. [PMID: 33025267 PMCID: PMC7538482 DOI: 10.1186/s40658-020-00327-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2019] [Accepted: 09/03/2020] [Indexed: 12/19/2022] Open
Abstract
This article presents a new perspective on the development of inorganic scintillator-based fiber dosimeters (IOSFDs) for medical radiotherapy dosimetry (RTD) focusing on real-time in vivo dosimetry. The scintillator-based optical fiber dosimeters (SFD) are compact, free of electromagnetic interference, radiation-resistant, and robust. They have shown great potential for real-time in vivo RTD. Compared with organic scintillators (OSs), inorganic scintillators (IOSs) have larger X-ray absorption and higher light output. Variable IOSs with maximum emission peaks in the red part of the spectrum offer convenient stem effect removal. This article outlines the main advantages and disadvantages of utilizing IOSs for SFD fabrication. IOSFDs with different configurations are presented, and their use for dosimetry in X-ray RT, brachytherapy (BT), proton therapy (PT), and boron neutron capture therapy (BNCT) is reviewed. Challenges including the percentage depth dose (PDD) deviation from the standard ion chamber (IC) measurement, the angular dependence, and the Cherenkov effect are discussed in detail; methods to overcome these problems are also presented.
Collapse
Affiliation(s)
- Liang Ding
- School of Engineering, Cardiff University, Cardiff, UK
| | - Qiong Wu
- Department of Pharmacy, General Hospital of Southern Theatre Command, Guangzhou, China
| | - Qun Wang
- Department of Pharmacy, Shanghai Baoshan Luodian Hospital, Shanghai, China
| | - Yamei Li
- Department of Pharmacy, Shanghai Baoshan Luodian Hospital, Shanghai, China
| | | | - Liang Zhao
- Department of Pharmacy, Shanghai Baoshan Luodian Hospital, Shanghai, China
- Institute for Translational Medicine Research, Shanghai University, Shanghai, China
| |
Collapse
|
4
|
Gamma Radiation-Induced Effects over an Optical Fiber Laser: Towards New Sensing Applications. SENSORS 2020; 20:s20113017. [PMID: 32466449 PMCID: PMC7308955 DOI: 10.3390/s20113017] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 05/22/2020] [Accepted: 05/24/2020] [Indexed: 11/16/2022]
Abstract
In the present work, the effect of gamma radiation on the performance of different types of erbium-doped fibers (EDFs) when they are used in a fiber ring cavity (FRC) configuration is studied. Several pieces of commercial EDF are gamma-ray irradiated with different doses to evaluate the output power variations over time. The influence of different doses, from 150 Gy to 1000 Gy, over the output power level measurement and their amplified spontaneous emission (ASE) are experimentally evaluated both in the C and L bands. By using an FRC configuration we can detect the presence of gamma radiation. We can also estimate the irradiation doses applied to EDFs by measuring the slope of the short-term emission power.
Collapse
|