Davis WT, Valdez-Delgado KK, Bennett C, Mann-Salinas E, Burnett GM, Bedford T, Albright-Trainer B, Savell SC, Sorensen D. Reliability of Continuous Noninvasive Hemoglobin Monitoring in Healthy Participants During En Route Care Training. Mil Med 2024; 189:448-455. [PMID: 39160881 DOI: 10.1093/milmed/usae151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 02/23/2024] [Accepted: 03/19/2024] [Indexed: 08/21/2024] Open
Abstract
INTRODUCTION Current standards for hemoglobin monitoring during air transports of U.S. combat wounded are invasive and intermittent. Fielded pulse co-oximeters can noninvasively measure total hemoglobin, but this parameter is not currently utilized. The primary objective of this study was to assess the percentage of vital sign measurements with successful capture of total noninvasive hemoglobin measurement using spectrophotometry-based technology for Hb (SpHb) measurements in healthy participants during training flights. Secondary objectives were to assess the feasibility of a novel electronic data capture mechanism from usual patient movement items and perform a pilot analysis of SpHb changes in healthy participants during transitions from ground to air transport. METHODS We conducted a feasibility study enrolling healthy participants who had hemodynamic monitoring during usual U.S. Air Force Critical Care Air Transport (CCAT) flight training exercises from 2022 to 2023. Usual CCAT monitoring equipment and currently used Masimo Rainbow® pulse co-oximeters had the capability to measure SpHb. After each training exercise, the study team wirelessly downloaded case files from patient monitors utilizing the Battlefield Assisted Trauma Distributed Observation Kit (BATDOKTM) Case Downloader application. We then calculated point and precision estimates for the percentage of time for successful SpHb capture during the exercise and compared this to pulse oximetry (SpO2) capture. An a priori precision analysis for percentage of flight-time with successful SpHb data capture and descriptive statistics were performed. This study received Exempt Determination by the 59th Medical Wing IRB. RESULTS We analyzed 26 records with mean monitoring durations of 94.5 [59.3-119.9] minutes during ground phases and 78.0 [59.9-106.5] minutes during flight phases. SpHb measures were successfully captured for 97.7% (n = 4,620) of possible ground measurements and 97.2% (n = 3,973) of possible in-flight measurements compared to 99.5% ground and 98.2% in-flight capture for SpO2. Mean intervals of missing SpHb data were 2 ± 5 minutes on the ground and 4 ± 6 minutes in-flight. Mean SpHb increased by 0.93 ± 0.96 g/dL during the ground phase, but had minimal changes during ascent, cruising altitude or descent. The BATDOKTM Case downloader completed transfer for all files. CONCLUSION Masimo Rainbow® SpHb pulse co-oximeters reliably captured continuous, noninvasive hemoglobin measurements using usual CCAT patient movement items in healthy participants during both ground and flight training. The BATDOKTM Case Downloader successfully imported case files from CCAT patient monitors. Mean SpHb measures had a small increase during the ground phase of monitoring followed by minimal changes when transitioning to flight altitude.
Collapse
Affiliation(s)
- William T Davis
- En route Care Research Center/59 MDW/ST, Defense Health Agency, Sam Houston, TX 78234, USA
- Department of Emergency Medicine, Brooke Army Medical Center, Fort Sam Houston, TX 78234, USA
- Department of Military and Emergency Medicine, Uniformed Services University, Bethesda, MD 20814, USA
| | | | - Christopher Bennett
- En route Care Research Center/59 MDW/ST, Defense Health Agency, Sam Houston, TX 78234, USA
| | - Elizabeth Mann-Salinas
- En route Care Research Center/59 MDW/ST, Defense Health Agency, Sam Houston, TX 78234, USA
| | - Gregory M Burnett
- Air Force Research Laboratory, 711 Human Performance Wing, Wright-Patterson AFB, OH 45433, USA
| | - Theresa Bedford
- Air Force Research Laboratory, 711 Human Performance Wing, Wright-Patterson AFB, OH 45433, USA
| | - Brooke Albright-Trainer
- Department of Anesthesiology, VCU Health, Richmond, VA 23249, USA
- Central VA Health Care System, Richmond, VA 23249, USA
| | - Shelia C Savell
- En route Care Research Center/59 MDW/ST, Defense Health Agency, Sam Houston, TX 78234, USA
| | - Derek Sorensen
- Air Force Research Laboratory, 711 Human Performance Wing, Wright-Patterson AFB, OH 45433, USA
| |
Collapse
|
2
|
Sekino M, Murakami Y, Sato S, Shintani R, Kaneko S, Iwasaki N, Araki H, Ichinomiya T, Higashijima U, Hara T. Modifications of peripheral perfusion in patients with vasopressor-dependent septic shock treated with polymyxin B-direct hemoperfusion. Sci Rep 2023; 13:7295. [PMID: 37147345 PMCID: PMC10163011 DOI: 10.1038/s41598-023-34084-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 04/24/2023] [Indexed: 05/07/2023] Open
Abstract
Abnormal peripheral perfusion (PP) worsens the prognosis of patients with septic shock. Polymyxin B-direct hemoperfusion (PMX-DHP) increases blood pressure and reduces vasopressor doses. However, the modification of PP following administration of PMX-DHP in patients with vasopressor-dependent septic shock have not yet been elucidated. A retrospective exploratory observational study was conducted in patients with septic shock treated with PMX-DHP. Pulse-amplitude index (PAI), vasoactive inotropic score (VIS), and cumulative fluid balance data were extracted at PMX-DHP initiation (T0) and after 24 (T24) and 48 (T48) h. Changes in these data were analyzed in all patients and two subgroups (abnormal PP [PAI < 1] and normal PP [PAI ≥ 1]) based on the PAI at PMX-DHP initiation. Overall, 122 patients (abnormal PP group, n = 67; normal PP group, n = 55) were evaluated. Overall and in the abnormal PP group, PAI increased significantly at T24 and T48 compared with that at T0, with a significant decrease in VIS. Cumulative 24-h fluid balance after PMX-DHP initiation was significantly higher in the abnormal PP group. PMX-DHP may be an effective intervention to improve PP in patients with abnormal PP; however, caution should be exercised as fluid requirements may differ from that of patients with normal PP.
Collapse
Affiliation(s)
- Motohiro Sekino
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
| | - Yu Murakami
- Department of Anesthesiology, Nagasaki Harbor Medical Center, 6-39 Shinchi, Nagasaki, 850-8555, Japan
| | - Shuntaro Sato
- Clinical Research Center, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Ryosuke Shintani
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Shohei Kaneko
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Naoya Iwasaki
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Hiroshi Araki
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Taiga Ichinomiya
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Ushio Higashijima
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| | - Tetsuya Hara
- Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan
| |
Collapse
|
3
|
Singleton M, Ghisi D, Memtsoudis S. Perioperative management in complex spine surgery: a narrative review. Minerva Anestesiol 2022; 88:396-406. [PMID: 35315618 DOI: 10.23736/s0375-9393.22.15933-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The last two decades have seen a significant increase in the number of spine surgical procedures performed worldwide. This type of surgery includes a wide variety of procedures, from mini-invasive discectomies to multi-level spinal arthrodesis and osteotomies. Moreover, different surgical approaches are described at different spine levels: the anesthesiologist should be aware of the potential benefits and risks for the patients and be prepared for their management. In this narrative review we seek to describe basic concepts of perioperative spine care and address evolving areas in which care is changing. We will discuss preoperative concerns, intraoperative management including airway management, choice of maintenance, intraoperative neuromonitoring and anesthetic effect, blood management and the dynamic topic of anesthetic and analgesic techniques. Finally, we will briefly address the issue of perioperative complications as they relate specifically to spine surgery.
Collapse
Affiliation(s)
- Michael Singleton
- Department of Anesthesiology, Critical Care, and Pain Management, Hospital for Special Surgery, New York, NY, USA.,Department of Anesthesiology, Weill Cornell Medical College, New York, NY, USA
| | - Daniela Ghisi
- Anesthesia, Intensive Care and Pain Therapy, Istituto Ortopedico Rizzoli, Bologna, Italy -
| | - Stavros Memtsoudis
- Department of Anesthesiology, Critical Care, and Pain Management, Hospital for Special Surgery, New York, NY, USA.,Department of Anesthesiology, Weill Cornell Medical College, New York, NY, USA.,Department of Public Health, Division of Epidemiology, Weill Cornell Medical College, New York, NY, USA
| |
Collapse
|
4
|
Kumar Y, Dogra A, Kaushik A, Kumar S. Progressive evaluation in spectroscopic sensors for non-invasive blood haemoglobin analysis - a review. Physiol Meas 2021; 43. [PMID: 34883473 DOI: 10.1088/1361-6579/ac41b7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 12/09/2021] [Indexed: 11/11/2022]
Abstract
Frequent monitoring of haemoglobin concentration is highly recommended by physicians to diagnose anaemia and polycythemia Vera. Moreover, Some other conditions also demand assessment of haemoglobin, and these conditions are blood loss, before blood donation, during pregnancy, preoperative, perioperative and postoperative conditions. Cyanmethaemoglobin/haemiglobincyanide method, portable haemoglobinometers and haematology analyzers are few standard methods to diagnose mentioned ailments. However, discomfort, delay and risk of infection are typical limitations of traditional measuring solutions. These limitations create the necessity to develop a non-invasive haemoglobin monitoring technique for a better lifestyle. Various methods and products are already developed and popular due to their non-invasiveness; however, invasive solutions are still considered as the reference standard method. Therefore, this review summarizes the attributes of existing non-invasive solutions. These attributes are finalized as brief details, accuracy, optimal benefits, and research challenges for exploring potential gaps, advancements and possibilities to consider as futuristic alternative methodologies. Non-invasive total haemoglobin assessing techniques are mainly based on optical spectroscopy (reflectance/transmittance) or digital photography or spectroscopic imaging in spot check/continuous monitoring mode. In all these techniques, we have noticed that there is a need to consider different light conditions, motion artefacts, melanocytes, other blood constituents, smoking and precise fixing of the sensor from the sensing spot for exact formulation. Moreover, based on careful and critical analysis of outcomes, none of these techniques or products is used independently or intended to replace invasive laboratory testing. Therefore there is a requirement for a more accurate technique that can eliminate the requirement of blood samples and likely end up as a reference standard method.
Collapse
Affiliation(s)
- Yogesh Kumar
- Biomedical Instrumentation, CSIR Central Scientific Instruments Organisation, ., Chandigarh, 160030, INDIA
| | | | - Ajeet Kaushik
- Department of Natural Sciences, Florida Polytechnic University, 4700 Research Way, IST#2018, Lakeland, Florida, 33805, UNITED STATES
| | - Sanjeev Kumar
- Biomedical Instrumentation, CSIR Central Scientific Instruments Organisation, ., Chandigarh, 160020, INDIA
| |
Collapse
|
5
|
Tayari H, Flaherty D, Schauvliege S, La Rosa L, Auckburally A. Accuracy and trending capability of haemoglobin measurement by noninvasive pulse co-oximetry in anaesthetized horses. Vet Anaesth Analg 2021; 49:76-84. [PMID: 34801406 DOI: 10.1016/j.vaa.2021.06.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 04/21/2021] [Accepted: 06/08/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To assess the accuracy and trending capability of continuous measurement of haemoglobin concentration [Hb], haemoglobin oxygen saturation (SaO2) and oxygen content (CaO2) measured by the Masimo Radical-7 pulse co-oximeter in horses undergoing inhalational anaesthesia. STUDY DESIGN Prospective observational clinical study. ANIMALS A group of 23 anaesthetized adult horses. METHODS In 23 healthy adult horses undergoing elective surgical procedures, paired measurements of pulse co-oximetry-based haemoglobin concentration (SpHb), SaO2 (SpO2), and CaO2 (SpOC) and simultaneous arterial blood samples were collected at multiple time points throughout anaesthesia. The arterial samples were analysed by a laboratory co-oximeter for total haemoglobin (tHb), SaO2 and manually calculated CaO2. Bland-Altman plots, linear regression analysis, error grid analysis, four-quadrant plot and Critchley polar plot were used to assess the accuracy and trending capability of the pulse co-oximeter. Data are presented as mean differences and 95% limits of agreement (LoA). RESULTS In 101 data pairs analysed, the pulse co-oximeter slightly underestimated tHb (bias 0.06 g dL-1; LoA -1.0 to 1.2 g dL-1), SaO2 (bias 1.4%; LoA -2.0% to 4.8%), and CaO2 (bias 0.3 mL dL-1; LoA -2.1 to 2.7 mL dL-1). Zone A of the error grid encompassed 99% of data pairs for SpHb. Perfusion index (PI) ≥ 1% was recorded in 58/101 and PI < 1% in 43/101. The concordance rate for consecutive changes in SpHb and tHb with PI ≥ 1% and < 1% was 80% and 91% with four-quadrant plot, and 45.8% and 66.6% with Critchley polar plot. CONCLUSIONS Pulse co-oximetry has acceptable accuracy for the values measured, even with low PI, whereas its trending ability requires further investigation in those horses with a higher [Hb] variation during anaesthesia.
Collapse
Affiliation(s)
- Hamaseh Tayari
- Southern Counties Veterinary Specialists, Anaesthesia Department, Ringwood, UK.
| | - Derek Flaherty
- Southern Counties Veterinary Specialists, Anaesthesia Department, Ringwood, UK
| | - Stijn Schauvliege
- Department of Surgery and Anaesthesia of Domestic Animals, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Lavinia La Rosa
- Department of Surgery and Anaesthesia of Domestic Animals, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Adam Auckburally
- Southern Counties Veterinary Specialists, Anaesthesia Department, Ringwood, UK
| |
Collapse
|
6
|
Selvaraj N, Jain G, Tripathy DK, Mittal A, Indulekha H. Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery. Indian J Anaesth 2021; 65:S62-S68. [PMID: 34188257 PMCID: PMC8191187 DOI: 10.4103/ija.ija_1067_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2020] [Revised: 10/04/2020] [Accepted: 01/12/2021] [Indexed: 11/25/2022] Open
Abstract
Background and Aims: The aim of this study was to evaluate the accuracy of non-invasive haemoglobin (SpHb) compared to laboratory venous haemoglobin (tHb) measurements among patients undergoing elective transurethral resection of prostate (TURP) surgery under spinal anaesthesia. Methods: In a prospective, observational, outcome-assessor blinded, cohort trial, we enroled 50 American Society of Anesthesiologists physical status (ASA-PS) I-II patients with benign prostatic hyperplasia. The primary outcome included SpHb and tHb measurements performed at four perioperative time-points: just before initiating the fluid preload (T1), and at 30 min (T2), 1 h (T3), and 2 h (T4) after starting the prostate resection, respectively. Statistical tool included intra-class correlation (ICC), Bland-Altman plots, and linear regression analysis. Results: We collected 200 SpHb/tHb data sets from 50 patients. The SpHb had a non-significant negative bias of –0.83 g/dL, –0.43 g/dL, –0.81 g/dL, and –0.46 g/dL, with limits of agreement of 2.6 g/dL to –4.2 g/dL, 2.4 g/dL to –3.3 g/dL, 1.3 g/dL to –2.8 g/dL, and 1.4 g/dL to –2.3 g/dL, for T1 to T4, respectively. The SpHb/tHb pairs correlated significantly (time-dependent increase in ICC from T1 to T4). The SpHb-tHb difference correlated significantly with corresponding serum sodium (T1 to T3), but not with perfusion index. No correlation existed between % change in SpHb-tHb difference (T1 to T4), and intraoperative blood loss or perioperative weight gain. Conclusion: The SpHb exhibited a clinically acceptable negative bias compared to tHb during TURP surgery. Although a wide limit of agreement between the SpHb/tHb pairs is a limitation, the real-time SpHb trends can still serve in clinical judgement.
Collapse
Affiliation(s)
- Naveen Selvaraj
- Departments of Anaesthesiology, All India Institute of Medical Sciences, Virbhadra Marg, Rishikesh, Uttarakhand, India
| | - Gaurav Jain
- Departments of Anaesthesiology, All India Institute of Medical Sciences, Virbhadra Marg, Rishikesh, Uttarakhand, India
| | - Debendra Kumar Tripathy
- Departments of Anaesthesiology, All India Institute of Medical Sciences, Virbhadra Marg, Rishikesh, Uttarakhand, India
| | - Ankur Mittal
- Department of Urology, All India Institute of Medical Sciences, Virbhadra Marg, Rishikesh, Uttarakhand, India
| | - Haritha Indulekha
- Departments of Anaesthesiology, All India Institute of Medical Sciences, Virbhadra Marg, Rishikesh, Uttarakhand, India
| |
Collapse
|
7
|
Hahn RG, Wuethrich PY, Zdolsek JH. Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin? BMC Anesthesiol 2021; 21:138. [PMID: 33957864 PMCID: PMC8101100 DOI: 10.1186/s12871-021-01351-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 04/19/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Trends in non-invasive measurements of blood hemoglobin (Hb) may be useful for identifying the need for transfusion in the perioperative period. METHODS Crystalloid fluid (5-20 mL/kg) was administered intravenously or by mouth to 30 volunteers and 33 surgical patients in five non-randomized clinical studies where Hb was measured on 915 occasions by non-invasive (Radical-7™) and invasive methodology. The hemodilution curves were compared by volume kinetic analysis and linear regression, with the slope and scattering of the data as key outcome measures. RESULTS The slope was 1.0, indicating unity between the two modes of measuring Hb when crystalloid fluid was infused in volunteers; however, only 40-45% of the variability in the non-invasive Hb could be explained by the invasive Hb. Patients undergoing major surgery, who showed the most pronounced hemodilution (median 24 g/L); non-invasive Hb explained 72% of the variability but indicated only half the magnitude of the invasive Hb changes (slope 0.48, P < 0.001 versus the volunteers). Simulations based on volume kinetic parameters from the volunteers showed 25% less plasma volume expansion after infusion when based on non-invasive as compared to invasive Hb, while no difference was found during infusion. CONCLUSIONS In volunteers the non-invasive Hb had good accuracy (low bias) but poor precision. In surgical patients the non-invasive Hb had good precision but systematically underestimated the hemodilution. Despite severe limitations, the non-invasive technology can be used to follow Hb trends during surgery if supported by occasional invasive measurements to assure acceptable quality of the hemodilution curve. TRIAL REGISTRATIONS ControlledTrials.gov NCT01195025, NCT01062776, NCT01458678, NCT03848507, and NCT01360333 on September 3, 2010, February 4, 2010, October 25, 2011, February 20, 2019, and May 25, 2011, respectively.
Collapse
Affiliation(s)
- Robert G Hahn
- Research Unit, Södertälje Hospital, Södertälje, and Karolinska Institutet at Danderyds Hospital (KIDS), Stockholm, Sweden.
| | - Patrick Y Wuethrich
- Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, CH-3010, Berne, Switzerland
| | - Joachim H Zdolsek
- Department of Anesthesiology and Intensive Care, and Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
8
|
Campos C, Calheiros J, Kreuzer M, Fernandes R, Pinto C, Seabra M, Vide S. Clinical implications of using non-invasive haemoglobin monitoring for red blood cell transfusion decision in hip arthroplasty. Transfus Apher Sci 2020; 59:102770. [PMID: 32381421 DOI: 10.1016/j.transci.2020.102770] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 03/23/2020] [Accepted: 03/24/2020] [Indexed: 01/28/2023]
Abstract
INTRODUCTION The decision to transfuse red blood cells requires accurate haemoglobin concentration values. In this study, we evaluated if continuous non-invasive haemoglobin (SpHb) measurement could substitute laboratory determined haemoglobin (LabHb) in patients undergoing elective hip replacement. As secondary objective, we analyzed the trend of the difference between techniques. MATERIALS/METHODS LabHb measurements were done using an automated analyser and SpHb measurements were acquired using Radical-7®. In randomly selected patients undergoing hip replacement, whenever blood was collected for LabHb, concomitant SpHb was recorded. Correlation, bias and accuracy of SpHb were calculated in comparison with LabHb. RESULTS 108 paired measurements were obtained from 43 patients. The Pearson R of the correlation between SpHb and LabHb was 0.7 (p < 0.001). Bland-Altman test revealed a bias of 1 ± 1.4 g dL-1, meaning Lab Hb was recurrently higher than SpHb. Limits of agreement were [-1.7; 3.8]. Considering RBC transfusion threshold of 8 g dL-1, we found that in two situations transfusion decision would differ based on the measurement considered. Trending ability of SpHb study showed a significant difference between preoperative and postoperative LabHb-SpHb. DISCUSSION There was a good correlation between SpHb and LabHb, while bias and limits of agreement were higher than those in literature. There was a limited trending ability of SpHb during the perioperative period. Despite this, using SpHb instead of LabHb for decision making regarding transfusion would only change the decision in 1.9 % of our cases. Our findings suggest that this device could be used as a reference but cannot replace venous puncture as gold standard.
Collapse
Affiliation(s)
- Cristiana Campos
- Department of Anesthesia, Unidade Local de Saúde de Matosinhos - Hospital Pedro Hispano, Matosinhos, Portugal
| | - José Calheiros
- Department of Anesthesia, Unidade Local de Saúde de Matosinhos - Hospital Pedro Hispano, Matosinhos, Portugal
| | - Matthias Kreuzer
- Technical University of Munich, School of Medicine, Department of Anesthesiology and Intensive Care, Klinikum rechts der Isar, Munich, Germany
| | - Raquel Fernandes
- Department of Anesthesia, Unidade Local de Saúde de Matosinhos - Hospital Pedro Hispano, Matosinhos, Portugal
| | - Carla Pinto
- Department of Anesthesia, Unidade Local de Saúde de Matosinhos - Hospital Pedro Hispano, Matosinhos, Portugal
| | - Manuel Seabra
- Department of Anesthesia, Unidade Local de Saúde de Matosinhos - Hospital Pedro Hispano, Matosinhos, Portugal
| | - Sérgio Vide
- Department of Anesthesia, Unidade Local de Saúde de Matosinhos - Hospital Pedro Hispano, Matosinhos, Portugal.
| |
Collapse
|
9
|
Multicenter comparison of three intraoperative hemoglobin trend monitoring methods. J Clin Monit Comput 2019; 34:883-892. [PMID: 31797199 PMCID: PMC7447626 DOI: 10.1007/s10877-019-00428-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 11/20/2019] [Indexed: 01/28/2023]
Abstract
Transfusion decisions are guided by clinical factors and measured hemoglobin (Hb). Time required for blood sampling and analysis may cause Hb measurement to lag clinical conditions, thus continuous intraoperative Hb trend monitoring may provide useful information. This multicenter study was designed to compare three methods of determining intraoperative Hb changes (trend accuracy) to laboratory determined Hb changes. Adult surgical patients with planned arterial catheterization were studied. With each blood gas analysis performed, pulse cooximetry hemoglobin (SpHb) was recorded, and arterial blood Hb was measured by hematology (tHb), arterial blood gas cooximetry (ABGHb), and point of care (aHQHb) analyzers. Hb change was calculated and trend accuracy assessed by modified Bland–Altman analysis. Secondary measures included Hb measurement change direction agreement. Trend accuracy mean bias (95% limits of agreement; g/dl) for SpHb was 0.10 (− 1.14 to 1.35); for ABGHb was − 0.02 (− 1.06 to 1.02); and for aHQHb was 0.003 (− 0.95 to 0.95). Changes more than ± 0.5 g/dl agreed with tHb changes more than ± 0.25 g/dl in 94.2% (88.9–97.0%) SpHb changes, 98.9% (96.1–99.7%) ABGHb changes and 99.0% (96.4–99.7%) aHQHb changes. Sequential changes in SpHb, ABGHb and aHQHb exceeding ± 0.5 g/dl have similar agreement to the direction but not necessarily the magnitude of sequential tHb change. While Hb blood tests should continue to be used to inform transfusion decisions, intraoperative continuous noninvasive SpHb decreases more than − 0.5 g/dl could be a good indicator of the need to measure tHb.
Collapse
|