Three-Dimensional Free-Breathing Whole-Heart Coronary Magnetic Resonance Angiography at 1.5 T: Gadobutrol-Enhanced Gradient-Echo Acquisition Sequence Versus Non-Contrast-Enhanced Steady-State Free Precession Sequence.
J Comput Assist Tomogr 2019;
43:919-925. [PMID:
31738205 DOI:
10.1097/rct.0000000000000933]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES
The objective of this study was to compare gadobutrol-enhanced gradient-echo sequence (GRE) acquisition with T2-prepared non-contrast-enhanced steady-state free precession (SSFP) in coronary magnetic resonance angiography at 1.5 T.
METHODS
Twenty-one subjects successfully completed GRE and SSFP acquisition. Signal-to-noise ratio (SNR), contrast-to-noise ratio, image quality, sharpness, visibility, length, and lumen diameter of vessels were analyzed by 2 experienced radiologists.
RESULTS
The SNR at whole left circumflex artery, left main artery, and proximal left descending artery (LAD) was significantly higher in SSFP acquisition (P < 0.05). The SNR of distal LAD was slightly higher in GRE acquisition (P < 0.05). The contrast-to-noise ratio at distal LAD, proximal and distal RCA were significantly higher with GRE acquisition (P < 0.05).
CONCLUSIONS
Double-dose gadobutrol-enhanced GRE and unenhanced SSFP coronary magnetic resonance angiography at 1.5 T have their own characteristics, and the combined use of the 2 methods may be taken into consideration.
Collapse