1
|
Madanchi M, Attinger-Toller A, Gjergjizi V, Majcen I, Cioffi GM, Epper A, Gnan E, Koch T, Zhi Y, Cuculi F, Bossard M. Treatment of coronary lesions with a novel crystalline sirolimus-coated balloon. Front Cardiovasc Med 2024; 11:1316580. [PMID: 38414923 PMCID: PMC10896972 DOI: 10.3389/fcvm.2024.1316580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 01/31/2024] [Indexed: 02/29/2024] Open
Abstract
Background There is mounting data supporting the use of drug-coated balloons (DCB) not only for treatment of in-stent restenosis (ISR), but also in native coronary artery disease. So far, paclitaxel-coated balloons represented the mainstay DCBs. The SeQuent® crystalline sirolimus-coated balloon (SCB) (B.Braun Medical Inc, Germany) represents a novel DCB, which allows a sustained release of the limus-drug. We evaluated its performance in an all-comer cohort, including complex coronary lesions. Methods Consecutive patients treated with the SeQuent® SCB were analyzed from the prospective SIROOP registry (NCT04988685). We assessed clinical outcomes, including major adverse cardiovascular events (MACE), target lesion revascularization (TLR), target vessel myocardial infarction (TV-MI) and cardiovascular death. Angiograms and outcomes were independently adjudicated. Results From March 2021 to March 2023, we enrolled 126 patients and lesions, of which 100 (79%) treated using a "DCB-only" strategy and 26 (21%) with a hybrid approach (DES + DCB). The mean age was 68 ± 10 years, 48 (38%) patients had an acute coronary syndrome. Regarding lesion characteristics, ISR was treated in 27 (21%), 11 (9%) underwent CTO-PCI and 59 (47%) of the vessels were moderate to severe calcified. Procedural success rate was 100%. At a median follow-up time of 12.7 (IQR 12; 14.2) months, MACE occurred in 5 patients (4.3%). No acute vessel closure was observed. Conclusions Our data indicates promising outcomes following treatment with this novel crystalline SCB in an all-comer cohort with complex coronary lesions. These results require further investigation with randomized trials.
Collapse
Affiliation(s)
- Mehdi Madanchi
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
- Department of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland
| | | | - Varis Gjergjizi
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
| | - Irena Majcen
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
- Department of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland
| | - Giacomo M. Cioffi
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
- McMaster University, Hamilton, ON, Canada
- Hamilton Health Sciences, Hamilton, ON, Canada
| | - Angelika Epper
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| | - Eleonora Gnan
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
- Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico di Milano, University of Milan, Milan, Italy
| | - Tanja Koch
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
| | - Yuan Zhi
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
| | - Florim Cuculi
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
- Department of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland
| | - Matthias Bossard
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
- Department of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland
| |
Collapse
|
2
|
Liu D, Xue Z, Qi J, Yin L, Duan B, Wu L, Yang K, Gao B, Cao Q, Mi J. Risk factors for instent restenosis of sirolimus-coated stents in coronary intervention for patients with unstable angina. Sci Rep 2024; 14:2537. [PMID: 38291094 PMCID: PMC10827786 DOI: 10.1038/s41598-024-52567-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Accepted: 01/20/2024] [Indexed: 02/01/2024] Open
Abstract
To investigate the instent restenosis rate of sirolimus-coated stents in percutaneous coronary intervention (PCI) and risk factors for in-stent restenosis, patients with unstable angina (UA) caused by coronary artery stenosis were enrolled, and all clinical and imaging data were analyzed. Among 143 enrolled patients with UA aged 35-83 (mean 60.9 ± 10.0) years enrolled, there were 114 (79.7%) male and 29 (20.3%) female patients. Arterial stenosis was present in one coronary artery in 6 (4.2%) patients, in two coronary arteries in 20 (14.0%) patients, in three arteries in 116 (81.1%), and in four coronary arteries in 1 (0.7%) patient. Stenting was successfully performed in all (100%) patients, and 181 stents were deployed. The quantitative flow ratio (QFR) was 0.92 ± 0.03 (range 0.84-0.96) immediately after stenting, and the TIMI was grade 3 in all patients. The diameter of the stents deployed ranged 2.25-4 mm (mean 3.04 ± 0.44) with a length ranging 10 mm to 104 mm (mean 32.73 ± 15.5). Follow-up angiography was performed in all patients with a duration of 1-92 (mean 15.0 ± 18.8) months. Instent restenosis ≥ 50% occurred in 25 (17.5%) patients. In univariate logistic regression analysis, significant (P < 0.05) risk factors for instent restenosis ≥ 50% were QFR (OR 0.036, 95% CI 0.13-0.97), stent diameter (OR 0.43, 95% CI 0.18-0.92), hypertension (OR 3.16, 95% CI 1.02-9.82), smoking (OR 0.31, 95% CI 0.11-0.89), and neutrophil count (OR 2.22, 95% CI 1.10-5.44). In multivariate analysis, QFR (OR 0.02, 95% CI 0.002-0.19), stent diameter (OR 0.06, 95% CI 0.005-0.59), hypertension (OR 6.75, 95% CI 1.83-35.72) and neutrophil count (OR 276.07, 95% CI 12.32-10,959.95) were significant (P < 0.05) independent risk factors for instent restenosis ≥ 50%. In conclusion, certain instent restenosis rates occurs after the sirolimus-eluted coronary stent deployment for the treatment of coronary artery stenosis in patients with UA, and quantitative flow ratio after stenting, stent diameter, hypertension, and neutrophil count are significant risk factors for instent restenosis of the sirolimus-coated stents in coronary intervention.
Collapse
Affiliation(s)
- Dongchao Liu
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Zheng Xue
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Jingxian Qi
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Liang Yin
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Bing Duan
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Lin Wu
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Kun Yang
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Bulang Gao
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Qinying Cao
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China
| | - Jie Mi
- Department of Cardiology, Shijiazhuang People's Hospital, 365 South Jianhua Street, Shijiazhuang, 050011, Hebei, China.
| |
Collapse
|