1
|
Harmouch W, Karnkowska B, Thakker R, Rasmussen P, Shalaby M, Khalife W, Alwash H, Motiwala A, Kumfa P, Gilani S, Jneid H, Rangasetty U. Cerebral Embolic Protection in Transcatheter Aortic Valve Implantation Using the Sentinel Cerebral Protection System: A Systematic Review and Meta-Analysis. Cardiol Ther 2024; 13:299-314. [PMID: 38340292 PMCID: PMC11093944 DOI: 10.1007/s40119-024-00359-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Accepted: 01/24/2024] [Indexed: 02/12/2024] Open
Abstract
INTRODUCTION Transcatheter aortic valve implantation (TAVI) plays a vital role in patients with symptomatic aortic stenosis. Despite the mortality benefit of TAVI, embolic stroke remains a feared complication. As a result, transcatheter cerebral embolic protection (TCEP) devices have been developed to reduce this risk. Given the ongoing debate of TCEP in TAVI, we performed a systematic review and meta-analysis of all randomized controlled trials to date to identify outcomes of periprocedural stroke using the Sentinel™ cerebral protection system (CPS). METHODS MEDLINE, Cochrane, and Scopus databases were utilized from inception until 12/2023. PRISMA criteria was utilized. Keywords included "cerebral embolic protection", "sentinel cerebral protection system", "transcatheter aortic valve implantation", and "transcatheter aortic valve replacement". Primary outcome was periprocedural stroke. Secondary outcomes included periprocedural disabling and non-disabling stroke, all-cause mortality, transient ischemic attack, delirium, acute kidney injury, vascular complications, bleeding, and pacemaker implantation. Risk ratios (RR) were measured via Mantel-Haenszel method with fixed analysis. Heterogeneity was assessed via chi-squared and Higgin's I2 test. RESULTS Four trials with 3528 patients were assessed. SAPIEN 3 was the most common bioprosthetic valve used. The average age was 79.4 years with 41.9% of the sample size being females. The most prevalent comorbidities were hypertension, diabetes mellitus, and coronary artery disease. There was no difference in periprocedural stroke in patients who underwent TAVI with the Sentinel™ CPS compared to no TCEP (RR 0.75, P = 0.12). Periprocedural disabling strokes were less likely in those who underwent TAVI with the Sentinel™ CPS compared to no TCEP (RR 0.41, P = 0.02) with a number needed to treat (NNT) of 123. All other outcomes did not reach statistical significance. CONCLUSIONS In our analysis, there was no difference between TAVI with the Sentinel™ CPS compared to TAVI without TCEP in regard to risk of periprocedural stroke; however, it was associated with a decreased risk of periprocedural disabling stroke.
Collapse
Affiliation(s)
- Wissam Harmouch
- Department of Internal Medicine, University of Texas Medical Branch, Galveston, TX, USA.
| | - Barbara Karnkowska
- Department of Internal Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Ravi Thakker
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Peter Rasmussen
- Department of Internal Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Mostafa Shalaby
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Wissam Khalife
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Haider Alwash
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Afaq Motiwala
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Paul Kumfa
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Syed Gilani
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Hani Jneid
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| | - Umamahesh Rangasetty
- Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA
| |
Collapse
|
2
|
Caetano L, Gibicoski TB, Rodriguez F, Scabello I, da Silva Neto EP, Iplinski B. Impact of carotid artery stenosis on outcomes of transcatheter aortic valve replacement: A systematic review and meta-analysis. Int J Cardiol 2024; 399:131670. [PMID: 38141726 DOI: 10.1016/j.ijcard.2023.131670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 12/03/2023] [Accepted: 12/18/2023] [Indexed: 12/25/2023]
Abstract
INTRODUCTION Carotid Artery Stenosis (CAS) is common in elderly patients undergoing Transcatheter Aortic Valve Replacement (TAVR). However, the impact of CAS on the outcomes of TAVR is unclear. PURPOSE This systematic review and meta-analysis aimed to compare the clinical and periprocedural outcomes in patients with and without CAS undergoing TAVR. METHODS PubMed, Embase, and Cochrane databases were searched until February 2023. We included studies that performed a direct comparison of outcomes of TAVR in CAS versus non-CAS patients. Data was extracted from published reports and the ROBINS-I tool was utilized for quality assessment. The R studio software (version 4.2.2) was adopted for statistical analysis. RESULTS Five observational studies and 111.915 patients were included. The mean age was 80.7 ± 8.2 years and 46.3% were female. The risk of stroke or transient ischemic attack was elevated in the group of patients with CAS (OR 1.44; 95% CI 1.07-1.95; p = 0.016). In contrast, myocardial infarction (OR 1.24; 95% CI 1.05-1.47; p = 0.074) and all-cause mortality (OR 0.99; 95% CI 0.73-1.35; p = 0.95) were not significantly different between CAS and non-CAS groups. Acute kidney injury and new pacemaker implantation did not differ between patients with and without CAS. CONCLUSIONS Our findings suggest that CAS is significantly associated with cerebrovascular events in patients undergoing TAVR, without significantly impacting all-cause mortality. Further prospective studies are needed for a more granular assessment of additional determinants of this association, such as unilateral vs. bilateral involvement and whether there is a threshold of CAS severity for increased risk.
Collapse
Affiliation(s)
- Lucas Caetano
- Department of Medicine, Federal University of Paraiba, Joao Pessoa, Brazil.
| | | | | | | | | | | |
Collapse
|
3
|
Wang B, Mei Z, Ge X, Li Y, Zhou Q, Meng X, An G. Comparison of outcomes of self-expanding versus balloon-expandable valves for transcatheter aortic valve replacement: a meta-analysis of randomized and propensity-matched studies. BMC Cardiovasc Disord 2023; 23:382. [PMID: 37525092 PMCID: PMC10388567 DOI: 10.1186/s12872-023-03397-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Accepted: 07/14/2023] [Indexed: 08/02/2023] Open
Abstract
BACKGROUND The postoperative outcomes of transcatheter aortic valve replacement (TAVR) with the new generation of self-expanding valves (SEV) and balloon-expandable valves (BEV) remain uncertain. METHODS We conducted a meta-analysis based on randomized controlled trials (RCTs) and propensity score-matched (PSM) studies to evaluate the performance of the new generation TAVR devices, with a focus on Edwards SAPIEN 3/Ultra BEV, Medtronic Evolut R/PRO SEV, and Boston ACURATE neo SEV. Our primary endpoints were mortality and complications at both 30 days and one year post-operation. RESULTS A total of 4 RCTs and 14 PSM studies were included. Our findings showed no significant difference between SEV and BEV regarding 30-day and 1-year mortality rates. ACURATE SEV required less permanent pacemaker implantation (PPI) at 30-day as compared to SAPIEN BEV, while Evolut SEV required a higher rate of PPI than SAPIEN BEV. The incidence of stroke, major or life-threatening bleeding (MLTB), major vascular complications (MVC), coronary artery obstruction (CAO) and acute kidney injury (AKI) did not differ significantly between the two groups. SEV had a larger effective orifice area (EOA) and lower mean transvalvular gradients (MPG) compared to BEV. However, there was an increased risk of paravalvular leakage (PVL) associated with SEV. CONCLUSIONS In terms of 30-day mortality, stroke, bleeding, MVC, AKI, CAO, and one-year mortality, there was comparability between the two valve types following TAVR. SEV was associated with better hemodynamic outcomes, except for a higher incidence of PVL. Compared to SAPIEN BEV, ACURATE SEV had a lower risk of PPI at 30 days, while Evolut SEV was associated with a higher risk of PPI. These findings underscore the importance of personalized valve selection.
Collapse
Affiliation(s)
- Baiqiang Wang
- National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan, China
| | - Zeyuan Mei
- National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan, China
| | - Xiao Ge
- National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan, China
| | - Yunyi Li
- National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan, China
| | - Quan Zhou
- National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan, China
| | - Xiao Meng
- National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan, China
| | - Guipeng An
- National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan, China.
| |
Collapse
|