Liu MX, Zhu KY, Li DL, Dong XX, Liang G, Grzybowski A, Pan CW. Corneal Biomechanical Characteristics in Myopes and Emmetropes Measured by Corvis ST: A Meta-Analysis. Am J Ophthalmol 2024; 264:154-161. [PMID: 38556185 DOI: 10.1016/j.ajo.2024.03.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 02/17/2024] [Accepted: 03/25/2024] [Indexed: 04/02/2024]
Abstract
PURPOSE To comprehensively identify the corneal biomechanical differences measured by Corvis ST between different degrees of myopia and emmetropia. DESIGN Systematic review and meta-analysis. METHODS Electronic databases, including PubMed, Embase, and Web of Science, were systematically searched for studies comparing the corneal biomechanics among various degrees of myopes and emmetropes using Corvis ST. The weighted mean differences and 95% confidence intervals were calculated. Meta-analysis was performed in high and nonhigh myopes and in myopes and emmetropes, respectively. RESULTS Eleven studies were included in this study. The meta-analysis among myopes and emmetropes included 1947 myopes and 621 emmetropes, and 443 high myopes and 449 nonhigh myopes were included in the meta-analysis among high and nonhigh myopia. Myopes showed the cornea with significantly longer time at the first applanation (A1t) and lower length at the second applanation (A2L) than emmetropes. High myopes showed significantly greater A1t, velocity at the second applanation (A2v), deformation amplitude at the highest concavity (HC-DA), and peak distance at the highest concavity (HC-PD) and decreased time at the second applanation (A2t) and radius of the highest concavity (HC-R). CONCLUSIONS Corneal biomechanics is different in myopia, especially in high myopia. Compared with nonhigh myopes, the corneas of high myopes deformed slower during the first applanation, faster during the second applanation, and showed greater deformation amplitude, indicating greater elasticity and viscidity.
Collapse
Affiliation(s)
- Min-Xin Liu
- School of Public Health (M.X.L., D.L.L., X.X.D., C.W.P.), Suzhou Medical College of Soochow University, Suzhou, China
| | - Ke-Yao Zhu
- Pasteurien College of Soochow University (K.Y.Z.), Suzhou, China
| | - Dan-Lin Li
- School of Public Health (M.X.L., D.L.L., X.X.D., C.W.P.), Suzhou Medical College of Soochow University, Suzhou, China
| | - Xing-Xuan Dong
- School of Public Health (M.X.L., D.L.L., X.X.D., C.W.P.), Suzhou Medical College of Soochow University, Suzhou, China
| | - Gang Liang
- Department of Ophthalmology (G.L.), The Affiliated Hospital of Yunnan University, Kunming, China
| | - Andrzej Grzybowski
- Institute for Research in Ophthalmology (A.G.), Foundation for Ophthalmology Development, Poznan, Poland
| | - Chen-Wei Pan
- School of Public Health (M.X.L., D.L.L., X.X.D., C.W.P.), Suzhou Medical College of Soochow University, Suzhou, China.
| |
Collapse
|
2
|
Wang D, Chang Y, Nan W, Zhang Y. Comparative analysis of corneal parameters in simple myopic anisometropia using Scheimpflug technology. Front Bioeng Biotechnol 2024; 12:1366408. [PMID: 38840667 PMCID: PMC11150699 DOI: 10.3389/fbioe.2024.1366408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/06/2024] [Indexed: 06/07/2024] Open
Abstract
Purpose This study aims to investigate the differences in binocular corneal parameters and their interrelation with binocular biometric parameters asymmetry in patients with simple myopic anisometropia, thereby elucidating the influence of myopia process on various corneal parameters. Methods In this cross-sectional study, 65 patients with anisometropia in monocular myopia were included. They were divided into low anisometropia group: 3.00D<Δ spherical equivalent (SE)≤-1.00D (Δ represents the difference between the two eyes, i.e., myopic data minus emmetropic data) and high anisometropia group: ΔSE ≤ -3.00D. Corneal and ocular biometric parameters were measured using Pentacam, Corvis ST, and IOL Master 700. Statistical analyses focused on the binocular corneal parameters asymmetry, using the contralateral emmetropia as a control. Results The mean age of participants was 18.5 ± 1.3 years, with the average SE for myopia and emmetropia being -2.93 ± 1.09D and -0.16 ± 0.41D, respectively. The central corneal thickness (CCT), flat keratometry (Kf), keratometry astigmatism (Ka), total corneal aberration (6 mm) (TOA), surface variance index (ISV), vertical asymmetry index (IVA), stress-strain index (SSI), and first applanation stiffness parameter (SPA1) and ambrosia relational thickness-horizontal (ARTh) showed significant differences between anisometropic fellow eyes (p < 0.05). There were significant differences in ΔIVA, Δ the difference between the mean refractive power of the inferior and superior corneas (I-S), Δ deviation value of Belin/Ambrósio enhanced ectasia display (BAD-D), Δ deformation amplitude ratio max (2 mm) (DAR)and Δ tomographic biomechanical index (TBI) (p < 0.05) in two groups. Asymmetry of corneal parameters was correlated with asymmetry of ocular biometric parameters. Anisometropia (ΔSE) was positively correlated with ΔIVA (r = 0.255, p = 0.040), ΔBAD-D (r = 0.360, p = 0.006), and ΔSSI (r = 0.276, p = 0.039) and negatively correlated with ΔDAR (r = -0.329, p = 0.013) in multiple regression analysis. Δ mean keratometry (Km), Δ anterior chamber depth (ACD), and Δ biomechanically corrected intraocular pressure (bIOP) were also associated with binocular corneal differences. Conclusion Compared to contralateral emmetropia, myopic eyes have thinner corneas and smaller corneal astigmatism. Myopic corneas exhibit relatively more regular surface morphology but are more susceptible to deformation and possess marginally inferior biomechanical properties. In addition, there is a certain correlation between anisometropia and corneal parameter asymmetry, which would be instrumental in predicting the development of myopia.
Collapse
Affiliation(s)
- Di Wang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
| | - Yue Chang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
| | - Weijin Nan
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yan Zhang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
3
|
Borrego-Sanz L, Morales-Fernández L, Saénz-Francés San Baldomero F, Díaz Valle D, Pato Cour E, Méndez Fernández R, García Feijóo J, Rodríguez Rodríguez L. Corneal Biomechanics in Non-infectious Uveitis Measured by Corvis ST: A Pilot Study. Ocul Immunol Inflamm 2023; 31:1765-1771. [PMID: 35980346 DOI: 10.1080/09273948.2022.2108462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 07/26/2022] [Indexed: 10/15/2022]
Abstract
PURPOSE To assess differences between corneal biomechanical properties in patients with non-infectious uveitis and healthy subjects using CorVis. METHODS 77 patients with non-infectious uveitis and 47 control subjects were recruited. Biomechanical parameters were measured: deformation amplitude (DA), A-1 length and A-2 length (L1, L2), A-1 velocity and A-2 velocity (V1, V2), peak distance (PD) and HC radius (highest concavity radius). AUC ROC and correlation between clinical variables and biomechanical properties were determined. RESULTS Lower HC Radius and IOPb and higher DA and V1 was found in uveitis group. Statistical differences between cases using systemic medications and those with topical treatment were found in L1. Differences were showed between those cases with active and inactive uveitis in PD, DA, V2 and L2. The biomechanical parameter with the best discriminatory capacity of uveitis disease was HC Radius. CONCLUSION Differences in corneal biomechanical properties between non-infectious uveitis and healthy eyes were found.
Collapse
Affiliation(s)
- Lara Borrego-Sanz
- Ophthalmology Department, Clínico San Carlos Hospital, Madrid, Spain
| | | | | | - David Díaz Valle
- Ophthalmology Department, Clínico San Carlos Hospital, Madrid, Spain
| | | | | | | | | |
Collapse
|
4
|
Xiang K, Chen J, Zhao W, Zhu Z, Ding L, Bulloch G, Du L, Xu X, Zhu M, He X. Changes of corneal biomechanics in children using orthokeratology and their roles in predicting axial length progression-A prospective 2-year study. Acta Ophthalmol 2023; 101:755-765. [PMID: 36959685 DOI: 10.1111/aos.15662] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 02/19/2023] [Accepted: 03/08/2023] [Indexed: 03/25/2023]
Abstract
PURPOSE To determine how orthokeratology (ortho-k) affects corneal biomechanical properties in myopia control and whether corneal biomechanical parameters can predict clinical efficacy of ortho-k. METHODS A total of 125 children 7-15 years of age using ortho-k lenses were followed in this clinical practice and data of their right eyes were analysed. Corneal biomechanical parameters and most ocular biometry were measured at baseline, 1 week, and at 1, 3, 6, 12, 18 and 24 months. Axial length (AL) was collected every 6 months after baseline measurements. RESULTS During the 2-year follow up, nine corneal biomechanical parameters, including deformation amplitude maximum (DA), varied between baseline and 1 week (p < 0.05) and stabilized during the rest of wearing period (p > 0.05). The mean AL increased from 25.02 ± 0.84 mm to 25.38 ± 0.81 mm and baseline DA strongly correlated with AL progression (Pearson r = 0.37). In the multiple regression models, baseline age, AL and DA were the independent factors for AL progression (R2 : 0.7849, 0.2180 in low and moderate myopes). The area under the receiver operating characteristic curves using the three variables for predicting excessive AL progression (>0.35 mm during 2 years) in low and moderate myopes was 0.902 and 0.698. CONCLUSIONS Corneal biomechanics firstly fluctuated before becoming stable with long-term ortho-k use. Corneal biomechanics was associated with AL progression in children wearing ortho-k lenses. DA combined with age and AL at baseline could predict AL progression in low myopes using ortho-k.
Collapse
Affiliation(s)
- Kaidi Xiang
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
- Department of Ophthalmology, Shanghai General Hospital, National Clinical Research Center for Eye Diseases, Center of Eye Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jun Chen
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
| | - Wenchen Zhao
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
- Department of Ophthalmology, Shanghai General Hospital, National Clinical Research Center for Eye Diseases, Center of Eye Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiao Tong University, Shanghai, China
| | - Zhuoting Zhu
- Ophthalmology, Centre for Eye Research Australia, University of Melbourne, Melbourne, Australia
| | - Li Ding
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
| | - Gabriella Bulloch
- Ophthalmology, Centre for Eye Research Australia, University of Melbourne, Melbourne, Australia
| | - Linlin Du
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
| | - Xun Xu
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
- Department of Ophthalmology, Shanghai General Hospital, National Clinical Research Center for Eye Diseases, Center of Eye Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiao Tong University, Shanghai, China
| | - Mengjun Zhu
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
| | - Xiangui He
- Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai Vision Health Center & Shanghai Children Myopia Institute, Shanghai, China
- Department of Ophthalmology, Shanghai General Hospital, National Clinical Research Center for Eye Diseases, Center of Eye Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
5
|
Yang Z, Wu B, Li Z, Yu M, Jiang J, Chen S, Xu S, Zeng J, Wang M, Yang X. Changes in Stress-Strain Index in School-Aged Children: A 3-Year Longitudinal Study. J Ophthalmol 2023; 2023:6680748. [PMID: 37868693 PMCID: PMC10590269 DOI: 10.1155/2023/6680748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 09/22/2023] [Accepted: 09/23/2023] [Indexed: 10/24/2023] Open
Abstract
Purpose To determine three-year change of the corneal biomechanical parameter stress-strain index (SSI) in schoolchildren aged 7- 9 years and their correlation with refractive error and axial length (AL). Methods This is a prospective cohort study. Data of the AL, refractive error, and corneal biomechanical parameter SSI were collected at baseline and a 3-year follow-up for 217 schoolchildren. SSI, AL, and refractive error were measured via corneal visualization Scheimpflug technology (Corvis ST), IOLMaster biometry, and cycloplegic refraction. Three years of changes in SSI and its association with refractive error and AL were analyzed. Participants were divided into persistent nonmyopia (PNM), newly developed myopia (NDM), and persistent myopia (PM). The three-year difference in SSI among the three groups was analyzed. Results After three years of follow-up, the corneal biomechanical parameter SSI decreased in all participants (P < 0.01). There was a negative correlation between the change in SSI and the change in AL (r = -0.205, P=0.002) and a positive correlation between the change in refractive error (r = 0.183, P=0.007). After three years of follow-up, there was a decrease in the SSI for the NDM, PM, and PNM participants, with a median change of -0.05 for PNM and -0.13 and -0.09 for the NDM and PM, respectively. There was a significant decrease in corneal biomechanical properties for NDM patients compared with PNM patients (P < 0.01). Conclusion In 7- to 9-year-old schoolchildren, SSI decreased after three years of the longitudinal study, and the change in SSI was correlated with the change in AL and refractive error. There was a rapid decrease in corneal biomechanical properties among newly developed myopic patients.
Collapse
Affiliation(s)
- Zhengfei Yang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Bo Wu
- South China Hospital, Shenzhen University, Shenzhen, China
| | - Zhouyue Li
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Mengting Yu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Jinyun Jiang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Shuyuan Chen
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Shengsong Xu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Junwen Zeng
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Mengyi Wang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Xiao Yang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
6
|
Huang T, Wang Y, Wang Z, Long Q, Li Y, Chen D. Complement-mediated inflammation and mitochondrial energy metabolism in the proteomic profile of myopic human corneas. J Proteomics 2023; 285:104949. [PMID: 37331426 DOI: 10.1016/j.jprot.2023.104949] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/23/2023] [Accepted: 06/05/2023] [Indexed: 06/20/2023]
Abstract
Myopia is one of the most common causes of visual impairment worldwide. To identify proteins related to myopiagenesis, data-independent acquisition proteomic analysis was performed using corneal lenticules of myopic patients who underwent small incision lenticule extraction surgery. A total of 19 lenticules from 19 age and sex-matched patients were analyzed, 10 in high refractive error (HR, spherical equivalent over -6.00 D) group and 9 in low refractive error (LR, spherical equivalent between -3.00 and - 1.00 D) group. Differentially expressed proteins (DEPs) were identified by comparing the corneal proteome between the two groups. Functional analyses were performed to explore the biological pathways and interactions of the DEPs. 107 DEPs (67 upregulated and 40 downregulated in HR group, compared to LR) were identified from 2138 quantified proteins. Functional analyses indicated that upregulated proteins were primarily involved in the complement pathways and extracellular matrix (ECM) remodeling, while downregulated proteins were involved in mitochondrial energy metabolism. Western blot analysis confirmed increased complement C3a and apolipoprotein E in HR samples, further supporting the proteomics data. In conclusion, this proteomic study reveals that proteins associated with the complement system, ECM remodeling, and mitochondrial energy metabolism might be key effectors in myopiagenesis. SIGNIFICANCE: Myopia has become one of the most prevalent causes of visual impairment, especially in Asia. The underlying mechanism of myopia development is still up for debate. This study compares the proteomic profiles of high and low myopic corneas, identifying differentially expressed proteins associated with the complement system, ECM remodeling, and mitochondrial energy metabolism. The findings of this study could provide novel insights into the pathogenesis of myopia. The complement system and mitochondrial energy metabolism may provide potential therapeutic targets in the treatment and prevention of myopia.
Collapse
Affiliation(s)
- Tianze Huang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100005, China
| | - Yuchen Wang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100005, China
| | - Zhonghai Wang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100005, China
| | - Qin Long
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100005, China
| | - Ying Li
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100005, China
| | - Di Chen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100005, China.
| |
Collapse
|
7
|
Hsia Y, Wei YH, Liao SL. The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease. Invest Ophthalmol Vis Sci 2023; 64:31. [PMID: 37494009 PMCID: PMC10382999 DOI: 10.1167/iovs.64.10.31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/27/2023] Open
Abstract
Purpose To investigate changes in ocular biomechanical response parameters and intraocular pressure (IOP) in patients with thyroid eye disease (TED) undergoing orbital decompression or anterior blepharotomy. Methods Eighty-three eyes from 46 patients receiving orbital decompression (the orbital decompression group) and 45 eyes from 28 patients receiving anterior blepharotomy (the anterior blepharotomy group) were retrospectively enrolled from a tertiary center. Corvis ST tonometry was used to assess ocular biomechanical response and biomechanically corrected IOP (bIOP) pre- and postoperatively. Non-contact tonometry (IOP-NCT) was also performed. Results In the anterior blepharotomy group, the margin reflex distance decreased (P < 0001). The highest concavity radius (P = 0.026) and whole eye movement (P = 0.003) increased. Neither IOP-NCT nor bIOP had a significant change. In the orbital decompression group, the extent of exophthalmos decreased (P < 0.001). The A2 length (P = 0.009) decreased. The bIOP did not show a significant change (16.4 ± 2.7 vs. 16.7 ± 4.5; P = 0.415), but the IOP-NCT decreased significantly (17.5 ± 3.3 vs. 16.0 ± 3.3; P < 0.001). Higher baseline IOP-NCT (β = -0.40, P < 0.001) and greater reduction in stiffness parameter A1 (SP-A1; β = 0.05, P = 0.002) were associated with more significant IOP-NCT reduction after the orbital decompression. Conclusions Ocular biomechanical response parameters may change after TED surgery, potentially affecting IOP measurements, particularly in patients receiving orbital decompression.
Collapse
Affiliation(s)
- Yun Hsia
- Department of Ophthalmology, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan
- Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan
| | - Yi-Hsuan Wei
- Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan
- College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Shu-Lang Liao
- Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan
- College of Medicine, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
8
|
Chen L, Huang Y, Zhang X, Shi Y, Gao Z, Sun B, Shen Y, Sun L, Cao Y, Zhang Q, Guo J, Li F, Chen W, Li X, Zhou X. Corneal Biomechanical Properties Demonstrate Anisotropy and Correlate With Axial Length in Myopic Eyes. Invest Ophthalmol Vis Sci 2023; 64:27. [PMID: 37477932 PMCID: PMC10365135 DOI: 10.1167/iovs.64.10.27] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 06/12/2023] [Indexed: 07/22/2023] Open
Abstract
Purpose The purpose of this study was to investigate the ex vivo and in vivo biomechanical characteristic of cornea in myopic eyes. Methods Fifty-one corneal stromal lenticules were obtained from myopic eyes during the SMILE procedure and were tested by a biaxial tensile system within 24 hours postoperatively. The material properties of the lenticules were described using stress-strain curves and were compared among axial length (AL) <26 mm and AL ≥ 26 mm group. Pre-operative stress-strain index (SSI) parameters were used to evaluate the biomechanical properties of the cornea in vivo. Results Compared with AL < 26 mm, the tangent modulus significantly decreased in horizontal and vertical directions when AL ≥ 26 mm (P < 0.05); SSI also significantly decreased when AL ≥ 26 mm (P < 0.05). Anisotropic parameter is positively correlated with AL (r = 0.307, P < 0.05). Compared with AL < 26 mm, anisotropic parameter significantly increased when AL ≥ 26 mm (P < 0.05). SSI was negatively correlated with AL (r = -0.380, P < 0.05) in the AL < 26 mm group but not in the AL ≥ 26 mm group (P > 0.05). Compared with 26 mm ≤ AL < 27 mm group, the tangent modulus significantly decreased in the horizontal direction (P < 0.05) but not in the vertical direction when 27 mm ≤ AL < 28 mm (P > 0.05). Conclusions The biomechanical properties of cornea decreased with the increase of AL. Tangent modulus significantly decreased in the horizontal direction compared with vertical direction. AL should be taken into account during calculation of corneal biomechanical parameters in order to improve validity.
Collapse
Affiliation(s)
- Lingfeng Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Yangyi Huang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Xiaoyu Zhang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yike Shi
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Zhipeng Gao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Bingqing Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yang Shen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Ling Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yifan Cao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Qianqian Zhang
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
- School of Automation and Software Engineering, Shanxi University, Taiyuan, Shanxi, China
| | - Jiqiang Guo
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
| | - Fen Li
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, Taiyuan, China
- Institute of Applied Mechanics, Taiyuan University of Technology, Taiyuan, China
| | - Weiyi Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Xiaona Li
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| |
Collapse
|
9
|
Özdoğan S, Gürelik G, Bilgihan K. Analysis of corneal biomechanical properties 25 years after myopic photorefractive keratectomy. Int Ophthalmol 2023; 43:325-331. [PMID: 35918497 DOI: 10.1007/s10792-022-02436-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 07/05/2022] [Indexed: 02/07/2023]
Abstract
PURPOSE To evaluate corneal biomechanical changes using Corvis ST in patients treated with photorefractive keratectomy (PRK) 25 years ago. METHODS In this study, 32 post-PRK and 38 normal eyes underwent Corvis ST (CST) assessments. The measured CST factors were: time of highest concavity (HC), time of applanation 1 (AT1), time of applanation 2 (AT2), length of applanation 1 (AL1), length of applanation 2 (AL2), velocity of applanation 1 (AV1), velocity of applanation 2 (AV2), deformation amplitude (DA), peak distance (PD), integrated radius (IR), Ambrosio relational thickness horizontal (ARTh), stiffness parameter at first applanation (SP-A1), DA ratio (2 mm), Belin/Ambrosio enhanced ectasia display (BAD) and corneal biomechanical index (CBI). RESULTS The mean [± standard deviation (SD)] age was 51.4 ± 7.36 years in PRK, 51.4 ± 3.62 in control group. PRK was performed 24.69 ± 1.78 years ago. ARTh, SP-A1, AT1, AL1, and AL2 were lower in PRK. PD, AT2, DA ratio (2 mm), and IR were statistically higher in PRK (P < 0.01). In PRK and control group the mean value of CBI was 0.91 ± 0.11 and 0.50 ± 0.27 (P < 0.001), and mean value of BAD was 3.34 ± 1.53 and 1.1 ± 0.70 (P < 0.001). In PRK 71.9% of eyes were classed "high risk CBI plus diseased BAD" and 25% remained in the "high risk CBI and normal BAD" group. CONCLUSIONS In this study, most of the post-PRK eyes which were clinically and topographically normal were classified as "high risk CBI plus diseased BAD" and had significantly worse CBI and BAD values than the control group. This leads to the conclusion that CBI and BAD alone are not appropriate to evaluate post-PRK ectasia.
Collapse
Affiliation(s)
- Sibel Özdoğan
- Dr. Abdurrahman Yurtarslan Oncology Training and Research Hospital, 06400, Ankara, Turkey.
| | - Gökhan Gürelik
- Departments of Ophthalmology, Gazi University Medical School, Ankara, Turkey
| | - Kamil Bilgihan
- Departments of Ophthalmology, Gazi University Medical School, Ankara, Turkey
| |
Collapse
|
10
|
Lu W, Ding W, Ji R, Tian Y, Zhao C, Li H, Jiao M, Guo Z, Leng L. Repeatability and correlation of corneal biomechanical measurements obtained by Corvis ST in orthokeratology patients. Cont Lens Anterior Eye 2022; 46:101793. [PMID: 36509642 DOI: 10.1016/j.clae.2022.101793] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 12/02/2022] [Accepted: 12/04/2022] [Indexed: 12/14/2022]
Abstract
PURPOSE To evaluate the repeatability of the corneal biomechanical measurements obtained by Corvis ST in post-orthokeratology patients and analyze the correlation between the biomechanical and ocular parameters. METHODS Fifty-one eyes of 51 myopic subjects were included in this study. The biomechanical parameters were assessed using Corvis ST. Repeatability was assessed using one-way ANOVA based on within-subject standard deviation (Sw), repeatability coefficient (RC), intraclass correlation coefficient (ICC) and correlation of variation (CoV). The correlation was evaluated using Pearson correlation analysis. RESULTS All parameters measured by Corvis ST, except length of flattened cornea at the first and second applanations (A1L and A2L), showed a good intraobserver repeatability after a 3-month follow-up period. The ICC values for A1L and A2L were 0.444 and 0.654, whereas the other parameters were higher than 0.8. Similar trends were obtained for CoV, wherein the CoV values for A1L and A2L were greater than 13 %. The corneal biomechanical parameters were correlated with age, refraction, axial length (AL), steep and flat keratometry before and after orthokeratology, and central corneal thickness (CCT). Following orthokeratology treatment, post-keratometry demonstrated a higher correlation with stiffness parameter at first applanation (SP-A1), velocity of corneal apex at the first applanation (A1V), and radius than pre-keratometry, which showed a weak correlation with SP-A1. CONCLUSION Corneal biomechanical parameters assessed using Corvis ST demonstrated a good repeatability, except A1L and A2L. The corneal biomechanical parameters were correlated with age, refraction, AL and pre- and post-keratometry. Thus, Corvis ST is a suitable device for investigating biomechanical parameter.
Collapse
Affiliation(s)
- Weicong Lu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China
| | - Wenzhi Ding
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China
| | - Rongyuan Ji
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China
| | - Yuyin Tian
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China
| | - Chenpei Zhao
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China
| | - Honglei Li
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China
| | - Mengjun Jiao
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China
| | - Zhen Guo
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China
| | - Lin Leng
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Shandong, China; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong, China; School of Ophthalmology, Shandong First Medical University, Shandong, China.
| |
Collapse
|
11
|
Solano MM, Richer E, Cheriet F, Lesk MR, Costantino S. Mapping Pulsatile Optic Nerve Head Deformation Using OCT. OPHTHALMOLOGY SCIENCE 2022; 2:100205. [PMID: 36531582 PMCID: PMC9754981 DOI: 10.1016/j.xops.2022.100205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 07/18/2022] [Accepted: 07/18/2022] [Indexed: 06/17/2023]
Abstract
OBJECTIVE To develop a noninvasive technique to quantitatively assess the pulsatile deformation due to cardiac contractions of the optic nerve head (ONH). DESIGN Evaluation of a diagnostic test or technology. PARTICIPANTS Healthy subjects with no history of refractive surgery, divided into 2 cohorts on the basis of their axial length (AL). METHODS We present a noninvasive technique to quantitatively assess the pulsatile deformation of the ONH tissue by combining high-frequency OCT imaging and widely available image processing algorithms. We performed a thorough validation of the approach, numerically and experimentally, evaluating the sensitivity of the method to artificially induced deformation and its robustness to different noise levels. We performed deformation measurements in cohorts of healthy (n = 9) and myopic (n = 5) subjects in different physiological strain conditions by calculating the amplitude of tissue displacement in both the primary position and abduction. The head rotation was measured using a goniometer. During imaging in abduction, the head was rotated 40° ± 3°, and subjects were instructed to direct their gaze toward the OCT visual target. MAIN OUTCOME MEASURES Pulsatile tissue displacement maps. RESULTS The robustness of the method was assessed using artificial deformations and increasing noise levels. The results show acceptable absolute errors before the noise simulations grossly exaggerate image degradation. For the group of subjects with AL of < 25 mm (n = 9), the median pulsatile displacement of the ONH was 7.8 ± 1.3 μm in the primary position and 8.9 ± 1.2 μm in abduction. The Wilcoxon test showed a significant difference (P ≤ 0.005) between the 2 paired measures. Reproducibility was tested in 2 different sessions in 5 different subjects with the same intraocular pressure, and an intraclass correlation coefficient of 0.99 was obtained (P < 0.005). CONCLUSIONS The computational pipeline demonstrated good reproducibility and had the capacity to accurately map the pulsatile deformation of the optic nerve. In a clinical setting, we detected physiological changes in normal subjects supporting its translation potential as a novel biomarker for the diagnosis and progression of optic nerve diseases.
Collapse
Affiliation(s)
- Marissé Masís Solano
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Quebec, Canada
- Department of Ophthalmology. Université de Montréal, Montreal, Quebec, Canada
| | - Emmanuelle Richer
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Quebec, Canada
- Department of Computer Engineering and Software Engineering, École Polytechnique de Montréal, Montreal, Quebec, Canada
| | - Farida Cheriet
- Department of Computer Engineering and Software Engineering, École Polytechnique de Montréal, Montreal, Quebec, Canada
| | - Mark R. Lesk
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Quebec, Canada
- Department of Ophthalmology. Université de Montréal, Montreal, Quebec, Canada
| | - Santiago Costantino
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Quebec, Canada
- Department of Ophthalmology. Université de Montréal, Montreal, Quebec, Canada
| |
Collapse
|
12
|
Gao R, Ren Y, Li S, Xu H, Lin X, McAlinden C, Ye J, Huang J, Yu J. Assessment of corneal biomechanics in anisometropia using Scheimpflug technology. Front Bioeng Biotechnol 2022; 10:994353. [PMID: 36338123 PMCID: PMC9632863 DOI: 10.3389/fbioe.2022.994353] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Accepted: 09/12/2022] [Indexed: 10/24/2023] Open
Abstract
Purpose: To investigate the relationship between corneal biomechanical and ocular biometric parameters, and to explore biomechanical asymmetry between anisometropic eyes using the corneal visualization Scheimpflug technology device (Corvis ST). Methods: 180 anisometropic participants were included. Participants were divided into low (1.00≤△Spherical equivalent (SE) < 2.00D), moderate (2.00D≤△SE < 3.00D) and high (△SE ≥ 3.00D) anisometropic groups. Axial length (AL), keratometry, anterior chamber depth (ACD) and corneal biomechanical parameters were assessed using the OA-2000 biometer, Pentacam HR and Corvis ST, respectively. Results: The mean age of participants was 16.09 ± 5.64 years. Stress-Strain Index (SSI) was positively correlated with SE (r = 0.501, p < 0.001) and negatively correlated with AL (r = -0.436, p < 0.001). Some other Corvis ST parameters had weak correlation with SE or AL. Corneal biomechanical parameters except for time of first applanation (A1T), length of second applanation (A2L), deformation amplitude (DA), first applanation stiffness parameter (SPA1) and ambrosia relational thickness-horizontal (ARTh) were correlated with ametropic parameters (SE or AL) in multiple regression analyses. A1T, velocity of first applanation (A1V), time of second applanation (A2T), A2L, velocity of second applanation (A2V), corneal curvature radius at highest concavity (HCR), peak distance (PD), DA, deformation amplitude ratio max (2 mm) (DAR), SPA1, integrated radius (IR), and SSI showed significant differences between fellow eyes (p < 0.05). There was no significant difference in asymmetry of corneal biomechanics among the three groups (p > 0.05). Asymmetry of some biomechanical parameters had weak correlation with asymmetry of mean corneal curvatures and ACD. However, asymmetry of corneal biomechanical parameters was not correlated with asymmetry of SE or AL (p > 0.05). Conclusion: More myopic eyes had weaker biomechanical properties than the contralateral eye in anisometropia. However, a certain linear relationship between anisometropia and biomechanical asymmetry was not found.
Collapse
Affiliation(s)
- Rongrong Gao
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Yuecheng Ren
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Siheng Li
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Huilin Xu
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Xuanqiao Lin
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Colm McAlinden
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Department of Ophthalmology, Singleton Hospital, Swansea Bay University Health Board, Swansea, United Kingdom
- Department of Ophthalmology, Royal Gwent Hospital, Aneurin Bevan University Health Board, Newport, United Kingdom
| | - Junming Ye
- Department Ophthalmology, Yiwu Central Hospital, Yiwu, Zhejiang, China
| | - Jinhai Huang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jinjin Yu
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| |
Collapse
|
13
|
Chu Z, Ren Q, Chen M, Cheng L, Cheng H, Cui W, Bi W, Wu J. The relationship between axial length/corneal radius of curvature ratio and stress–strain index in myopic eyeballs: Using Corvis ST tonometry. Front Bioeng Biotechnol 2022; 10:939129. [PMID: 36046672 PMCID: PMC9420864 DOI: 10.3389/fbioe.2022.939129] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Accepted: 07/13/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose: This study aimed to investigate the correlation of axial length/corneal radius of curvature ratio with stress–strain index (SSI).Methods: Retrospective analysis was conducted to compare the right eyes of those with high myopia (HM, n = 132; age and 10–48 years) with those without high myopia (NHM, n = 135; age and 7–48 years), where the baseline axial length, corneal radius of curvature ratio, and central corneal thickness were analyzed; the differences in two groups were compared; and the relationship of axial length and axial length/corneal radius of curvature ratio with SSI were explored.Results: Compared with AL < 26mm, SSI significantly decreased when AL ≥ 26 mm (p = 0.001), while there was no correlation with AL in the NHM group (r = -0.14, p = 0.12) or HM group (r = -0.09, p = 0.32). AL/CR was significantly associated with SSI in both the NHM (r = -0.4, p < 0.001) and HM (r = -0.18, p = 0.04) groups. In the NHM group, AL/CR was significantly associated with SSI (unstandardized beta = -0.514, se = 0.109, p < 0.001) with the adjustment of age and gender. Additionally, a significant association of SSI with AL/CR was also found after adjusting for age and gender (unstandardized beta = -0.258, se = 0.096, and p = 0.0082) in the HM group.Conclusion: SSI showed a significant negative correlation with AL/CR in patients without high myopia and in patients with high myopia. However, SSI exhibited no decrease with the worsening of myopia, but it gradually remained stable at a low level. The findings of this study validate, to some extent, the possibility of analyzing the dynamic changes in ocular wall stiffness during the development of myopia by measuring in vivo corneal biomechanical parameters.
Collapse
Affiliation(s)
- Zhe Chu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Qi Ren
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Meizhen Chen
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University Guangzhou, Guangzhou, China
| | - Lu Cheng
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University Guangzhou, Guangzhou, China
| | - Hao Cheng
- Department of Ophthalmology, the First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Wei Cui
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Wenjiao Bi
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
| | - Jie Wu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, China
- *Correspondence: Jie Wu,
| |
Collapse
|
14
|
Association of Iris Structural Measurements with Corneal Biomechanics in Myopic Eyes. DISEASE MARKERS 2022; 2021:2080962. [PMID: 35003388 PMCID: PMC8741339 DOI: 10.1155/2021/2080962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 12/07/2021] [Indexed: 11/25/2022]
Abstract
Purpose To evaluate the relationship between iris sectional parameters on swept-source optical coherence tomography (SS-OCT) with corneal biomechanics measured by Corneal Visualization Scheimpflug Technology (Corvis ST) in young adults with myopia. Methods 117 patients with myopia aged ≥18 years were recruited from the Eye Hospital of Wenzhou Medical University, who had complete SS-OCT and Corvis ST data. Only the left eye of each participant was selected for analysis. Iris sectional parameters included iris thickness at 750 μm from the scleral spur (IT750), iris sectional area (I-area), and iris curvature (I-curv) measured from four quadrants. Associations between the iris parameters and corneal biomechanics were analyzed using linear regression models. Results The mean age of the included young adults was 26.26 ± 6.62 years old with 44 males and 73 females. The iris parameters were different among the four quadrants. The nasal, temporal, and inferior quadrants of IT750, together with nasal and temporal quadrants of I-area, were correlated with corneal biomechanical parameters after being adjusted for age, gender, pupil diameter, and axial length. Thicker IT750 and larger I-area were related to a softer cornea. However, no association was found between I-curv and corneal biomechanics. Conclusions Iris sectional parameters measured from SS-OCT images were associated with corneal biomechanical properties in myopic eyes. Thicker IT750 and larger I-area indicate a softer cornea. IT750 and I-area may provide useful information on corneal biomechanical properties in myopic eyes.
Collapse
|
15
|
Lin Q, Shen Z. Effect of white-to-white corneal diameter on biomechanical indices assessed by Pentacam Scheimpflug corneal tomography and corneal visualization Scheimpflug technology. Int Ophthalmol 2022; 42:1537-1543. [PMID: 34988748 DOI: 10.1007/s10792-021-02144-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 11/19/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE To provide evidence for more accurate evaluation of refractive surgery candidates in clinics, this retrospective study investigated the effect of corneal diameter on the biomechanical indices assessed by Pentacam Scheimpflug cornea tomography (Pentacam) and corneal visualization Scheimpflug technology (Corvis ST). METHODS The relevant data were collected of 132 eyes from 132 participants with moderate myopia who were candidates for refractive surgery. Eligible participants were apportioned to 2 groups based on the white-to-white (WTW) corneal diameter: Group A, ≤ 11.5 mm, and Group B, ≥ 11.6 mm. A single clinician performed Pentacam and Corvis ST imaging on each subject for 3 consecutive measurements, and the means were used for statistical analyses. RESULTS Each group comprised 66 eyes. As measured by Pentacam, the 2 groups were comparable regarding Df and Da. For other measurements, Group A had significantly higher K1, K2, Db, Dp, Dt, Do, PPImin, PPImax, PPIavg, while Group B had significantly higher CCT, BFSf, BFSb, and ARTmax. Corvis ST data included DA ratio, SPA1, CBI, TBI, and ARTh. Only the latter showed a significant difference, with ARTh of group A (437.04 ± 76.60) larger than group B (470.46 ± 103.36, p = 0.04). CONCLUSION In a Chinese population, WTW corneal diameter showed effect on biomechanical indices assessed by Pentacam and Corvis ST. Personalized evaluation of these measurements based on corneal diameter should improve the sensitivity and specificity for screening of keratoconus by these devices.
Collapse
Affiliation(s)
- Qinghong Lin
- Department of Refractive Surgery, Hefei Bright Eye Hospital, No. 299 Feixi Road, Hefei, 230000, China
| | - Zhengwei Shen
- Department of Refractive Surgery, Hefei Bright Eye Hospital, No. 299 Feixi Road, Hefei, 230000, China.
| |
Collapse
|
16
|
Liu G, Rong H, Zhang P, Xue Y, Du B, Wang B, Hu J, Chen Z, Wei R. The Effect of Axial Length Elongation on Corneal Biomechanical Property. Front Bioeng Biotechnol 2021; 9:777239. [PMID: 34926423 PMCID: PMC8677453 DOI: 10.3389/fbioe.2021.777239] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 11/15/2021] [Indexed: 01/15/2023] Open
Abstract
Background: To investigate the correlation between the corneal biomechanical parameter stress-strain index (SSI) and axial length (AL) in moderately elongated eye (MEE) and severely elongated eye (SEE). Methods: This study included 117 eyes from 117 participants. Among them, 59 (50.4%) had MEE (AL<26 mm) and 58 (49.6%) had SEE (AL≥26 mm). AL was measured using Lenstar LS-900, and central corneal thickness (CCT) and anterior chamber volume (ACV) were measured using Pentacam. SSI was measured via corneal visualisation Scheimpflug technology (Corvis ST). Kolmogorov-Smirnov test, Student’s t-test, and Pearson and partial correlation analyses were used for statistical analyses. Results: The mean (±SD) SSI was 1.08 ± 0.15 in the MEE group and 0.92 ± 0.13 in the SEE group (p < 0.01). SSI was positively correlated with age (MEE: r = 0.326, p < 0.05; SEE: r = 0.298, p < 0.05) in both groups; it was negatively correlated with AL (r = −0.476, p < 0.001) in the MEE group but not in the SEE group (p > 0.05). CCT was negatively correlated with AL (r = −0.289, p < 0.05) and ACV positively correlated with AL (r = 0.444, p < 0.001) in the MEE group. Neither CCT nor ACV was correlated with AL (p > 0.05) in the SEE group. Conclusion: Corneal biomechanical parameter SSI, which represents the stiffness of corneal tissue, was lower in the SEE group than in the MEE group. When analyzed separately, SSI was negatively correlated with AL in the MEE group, but not in the SEE group, which may provide insight into different ocular growth patterns between lower myopia and higher myopia.
Collapse
Affiliation(s)
- Guihua Liu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Hua Rong
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Ping Zhang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yu Xue
- NHC Key Laboratory of Myopia, Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China.,Key Laboratory of Myopia, Shanghai Research Center of Ophthalmology and Optometry, Chinese Academy of Medical Sciences, Shanghai, China
| | - Bei Du
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Biying Wang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Jiamei Hu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Zhi Chen
- NHC Key Laboratory of Myopia, Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China.,Key Laboratory of Myopia, Shanghai Research Center of Ophthalmology and Optometry, Chinese Academy of Medical Sciences, Shanghai, China
| | - Ruihua Wei
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| |
Collapse
|
17
|
Xin Y, Kang BS, Zheng YP, Shan SW, Kee CS, Tan Y. Biophysical properties of corneal cells reflect high myopia progression. Biophys J 2021; 120:3498-3507. [PMID: 34022236 DOI: 10.1016/j.bpj.2021.05.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 04/07/2021] [Accepted: 05/17/2021] [Indexed: 01/07/2023] Open
Abstract
Myopia is a common ocular disorder with significant alterations in the anterior ocular structure, including the cornea. The cell biophysical phenotype has been proposed to reflect the state of various diseases. However, the biophysical properties of corneal cells have not been characterized during myopia progression and their relationship with myopia remains unknown. This study characterizes the biophysical properties of corneal cells in normal, myopic, and recovered conditions, using two classical myopia models. Surprisingly, myopic corneal cells considerably reduce F-actin and microtubule content and cellular stiffness and generate elevated traction force compared with control cells. When myopia is restored to the healthy state, these biophysical properties are partially or fully restored to the levels of control cells. Furthermore, the level of chromatin condensation is significantly increased in the nucleus of myopic corneal cells and reduced to a level similar to healthy cells after recovery. These findings demonstrate that the reversible biophysical alterations of corneal cells reflect myopia progression, facilitating the study of the role of corneal cell biophysics in myopia.
Collapse
Affiliation(s)
- Ying Xin
- The Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China; Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Byung Soo Kang
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong, China
| | - Yong-Ping Zheng
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Sze Wan Shan
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong, China
| | - Chea-Su Kee
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong, China.
| | - Youhua Tan
- The Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China; Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
| |
Collapse
|
18
|
Comparison of corneal biomechanics among primary open-angle glaucoma with normal tension or hypertension and controls. Chin Med J (Engl) 2021; 134:1087-1092. [PMID: 33813516 PMCID: PMC8116033 DOI: 10.1097/cm9.0000000000001399] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Background: Normal tension glaucoma (NTG) is a less pressure-dependent type of glaucoma with characteristic optic neuropathy. Recently, the biomechanical mechanism has been thought to account for glaucomatous optic neuropathy to some degree. We intended to compare dynamic corneal response parameters (DCRs) among patients with primary open-angle glaucoma with normal tension or hypertension and controls. The correlations between DCRs and known risk factors for glaucoma were also analyzed. Methods: In this cross-sectional study, 49 NTG subjects, 45 hypertension glaucoma (HTG) subjects, and 50 control subjects were enrolled. We compared the differences in DCRs using corneal visualization Scheimpflug technology among the NTG, HTG, and control groups. We also analyzed the correlations between DCRs and known risk factors for glaucoma (eg, central corneal thickness [CCT], intraocular pressure [IOP], etc). Results: The maximum inverse concave radius (NTG: 0.18 [0.17, 0.20] mm−1; control: 0.17 [0.16, 0.18] mm−1; P = 0.033), deformation amplitude ratio of 2 mm (DAR 2 mm, NTG: 4.87 [4.33, 5.39]; control: 4.37 [4.07, 4.88]; P < 0.001), and DAR 1 mm (NTG: 1.62 [1.58, 1.65]; control: 1.58 [1.54, 1.61]; P < 0.001) were significantly higher in NTG than in the controls. The integrated radius (IR, NTG: 8.40 ± 1.07 mm−1; HTG: 7.64 ± 1.31 mm−1; P = 0.026) and DAR 2 mm (NTG: 4.87 [4.33, 5.39]; HTG: 4.44 [4.12, 5.02]; P < 0.007) were significantly higher, whereas the stiffness parameter at the first applanation (SP-A1, NTG: 91.23 [77.45, 107.45]; HTG: 102.36 [85.77, 125.12]; P = 0.007) was lower in NTG than in HTG. There were no significant differences in the DCRs between HTG and control groups (P > 0.05). In the univariate and multivariate analyses, some of the DCRs, such as IR, were negatively correlated with CCT and IOP, whereas SP-A1 was positively correlated with CCT and IOP. Conclusions: The cornea was more deformable in NTG than in HTG or controls. There were no significant differences in corneal deformability between HTG and controls. The cornea was more deformable with the thinner cornea and lower IOP.
Collapse
|