Muacevic A, Adler JR. A Study Linking Axial Length, Corneal Curvature, and Eye Axis With Demographic Characteristics in the Emmetropic Eyes of Bangladeshi People.
Cureus 2022;
14:e29925. [PMID:
36225244 PMCID:
PMC9536359 DOI:
10.7759/cureus.29925]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2022] [Indexed: 11/05/2022] Open
Abstract
Background Axial length (AL) and corneal curvature (CC) are one of the furthest critical parameters for optometry and oculoplastic surgery. These two variables are crucial in biometry for accurately measuring the power of the intraocular lens in cataract surgery. This research aimed to determine the association linking axial length and corneal curvature with demographic characteristics in emmetropic eyes of Bangladeshi people. Methods This descriptive cross-sectional research was carried out among 200 emmetropic eyes of Bangladeshi people attending the Department of Ophthalmology at Rajshahi Medical College, Bangladesh, with different eye conditions, between July 2017 and June 2018. Data was gathered by conducting person-to-person interviews, checking visual activity using the Snellen chart, and measuring corneal curvature using an auto-keratometer and axial eyeball length using A-scan ultrasonography. Results A total of 200 attendances were studied, 90 males and 110 females. All were emmetropic. The age range was 21-52 years, and the highest contributors were in the 21-30-year age group. The association between right axial length and right corneal curvature shows a negative relation among both sexes. It was -0.61 (β-coefficient (β-coff)), and highly significant in females at -0.89 (β-coff). Additionally, the association between left axial length and left corneal curvature shows a negative relation of -0.65 (β-coff), which was again highly significant in females at -0.87 (β-coff). Both were not significant in males. There was no significant association linking axial length and eye axis in both sexes. The multivariate regression model was used to assess the p-value, and the regression model was adjusted by age. Conclusion Optical parametric measurement is a noninvasive diagnostic and assessment tool that might help in the actual measurement of intraocular lens implantation in cataract surgery and may also provide supplementary information to the researcher domain.
Collapse