Lu H, Li Y, Ren K, Li Z, Liu J, Duan X, Ren J, Han X. Covered SEMS failed to cure airway fistula closed by an amplatzer device.
BMC Pulm Med 2023;
23:270. [PMID:
37474964 PMCID:
PMC10357874 DOI:
10.1186/s12890-023-02548-8]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 07/03/2023] [Indexed: 07/22/2023] Open
Abstract
BACKGROUND
Airway fistula is a rare but threatening complication associated with high rates of morbidity and mortality. We report the experience of Amplatzer device application in airway fistulae that failed to be cured with a covered self-expandable metallic stent (SEMS).
MATERIALS AND METHODS
Patients who failed occlusion with a covered self-expandable metallic stent and received Amplatzer device placement from Jan 2015 to Jan 2020 were retrospectively enrolled. A total of 14 patients aged 42 to 66 years (55.14 ± 7.87) were enrolled in this study. The primary diseases, types of fistula, types of stents, duration, size of fistula, and follow-up were recorded.
RESULTS
All 14 patients with airway fistula failed to be occluded with a covered metallic stent and received Amplatzer device placement. Among the 14 patients, 6 had BPF, 3 had TEF and 5 had GBF. The average stent time was 141.93 ± 65.83 days. The sizes of the fistulae ranged from 3 to 6 mm. After Amplatzer device placement, the KPS score improved from 62.14 ± 4.26 to 75.71 ± 5.13 (P < 0.05). No procedure-related complications occurred. During the 1-month, 3-month and 6-month follow-ups, all the Amplatzer devices were partially surrounded with granulation. Only 1 patient with BPF failed with Amplatzer device occlusion due to the recurrence of lung cancer.
CONCLUSION
In conclusion, the application of the Amplatzer device is a safe and effective option in the treatment of airway fistula that failed to be occluded with SEMSs.
Collapse