1
|
Singh N, Awasthi A, Pisulkar G, Taywade S, Samal N. Adverse Metal Reaction in a Case of Metal-on-Polyethylene Hip Arthroplasty. Cureus 2024; 16:e60810. [PMID: 38910664 PMCID: PMC11189828 DOI: 10.7759/cureus.60810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 04/30/2024] [Indexed: 06/25/2024] Open
Abstract
Soft tissue inflammatory responses to metal debris from prostheses, categorised as adverse reactions to metal debris (ARMD), are frequent complications of total hip arthroplasty (THA) and often result in implant failure. Introducing modular implant designs in modern orthopaedics has brought benefits to total hip replacements but has also increased patients' susceptibility to corrosion-related risks. ARMD can develop from various metal articulating surfaces, including ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), metal-on-metal (MoM), and metal-on-polyethylene (MoP) configurations. In this case study, a 68-year-old male who underwent a MoP implant for osteoarthritis of the right hip 16 years ago presented with pain and difficulty walking, exacerbated over the past three months. Clinical examination revealed tenderness around the implant and a limited range of motion. Imaging studies, including X-rays and ultrasound-guided aspiration, coupled with normal serum and urinary cobalt (Co) and chromium (Cr) levels, confirmed the diagnosis of ARMD. Given the severity of symptoms and radiographic findings, surgical intervention was warranted, leading to a two-stage revision with implant augmentation using a Burch-Schneider cage. Three months post operation, the patient experienced significant improvements in pain levels, range of motion (ROM), and hip function. This case underscores the importance of vigilant surveillance for ARMD in patients undergoing non-MoM THA, even years post surgery. Prompt recognition and management of ARMD are crucial to mitigate the risk of long-term complications and optimise patient outcomes. Further research is needed to understand the risk factors and mechanisms underlying ARMD in MoP THA, aiding in developing preventive strategies and refined treatment protocols.
Collapse
Affiliation(s)
- Nikhil Singh
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| | - Abhiram Awasthi
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| | - Gajanan Pisulkar
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| | - Shounak Taywade
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| | - Nitin Samal
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| |
Collapse
|
2
|
Cannella A, Greco T, Polichetti C, De Martino I, Mascio A, Maccauro G, Perisano C. A Rare Case of Adverse Reaction to Metal Debris in a Ceramic-on-Ceramic Total Hip Replacement. J Funct Biomater 2022; 13:145. [PMID: 36135580 PMCID: PMC9501357 DOI: 10.3390/jfb13030145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 09/02/2022] [Accepted: 09/05/2022] [Indexed: 11/17/2022] Open
Abstract
Adverse Reaction to Metal Debris (ARMD) is one of the most frequent complications after Total Hip Replacement (THR) and often a cause of surgical revision. This is true especially for implants with Metal-on-Metal (MoM) and Large Diameter Heads (LDHs), which are frequently used to improve stability and reduce the risk of dislocation. However, ARMD is not exclusive to MoM replacement, as it can also occur in other implants such Ceramic-on-Ceramic (CoC), Metal-on-Polyethylene (MoP), and Ceramic-on-Polyethylene (CoP). In these non-MoM implants, ARMD is not caused by the tribo-corrosion between bearing surfaces but, rather, by the fretting at the interface between neck and stem of dissimilar metals. A case of a severe ARMD that happened to a 73-year-old female patient with CoC bearing THR at the right hip is presented in this case report. In this case, the ARMD was misdiagnosed for over a year, resulting in the development of a massive pseudotumor. The treatment of choice was a two-stage revision with the implant of a hip megaprosthesis. After more than 2 years of follow-up, complete recovery of hip Range of Motion (ROM) and normalization of chromium and cobalt levels in blood and urine were achieved. Despite the relatively short follow-up period, this can be considered a successful treatment of a major and misdiagnosed ARMD in a non-MoM hip replacement.
Collapse
Affiliation(s)
- Adriano Cannella
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Tommaso Greco
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Chiara Polichetti
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Ivan De Martino
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Antonio Mascio
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Giulio Maccauro
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Carlo Perisano
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| |
Collapse
|
3
|
Abstract
Choice of articulating materials, head size and the design of the articulation will become decisive for the long-term performance of a total hip arthroplasty (THA) and especially in terms of risk for dislocation and wear-related problems. Here we account for common alternatives based on available studies and the evidence that can be derived from them.Metal or ceramic femoral heads articulating against a liner or cup made of highly cross-linked polyethylene and ceramic-on-ceramic articulations have about similar risk for complications leading to revision, whereas the performance of metal-on-metal articulations, especially with use of big heads, is inferior. The clinical significance of problems related to ceramic-on-ceramic articulations such as squeaking remains unclear. With use of current technology ceramic fractures are rare.Large femoral heads have the potential to increase the range of hip movement before impingement occurs and are therefore expected to reduce dislocation rates. On the other hand, issues related to bearing wear, corrosion at the taper-trunnion junction and groin pain may arise with larger heads and jeopardize the longevity of THA. Based on current knowledge, 32-mm heads seem to be optimal for metal-on-polyethylene bearings. Patients with ceramic-on-ceramic bearings may benefit from even larger heads such as 36 or 40 mm, but so far there are no long-term reports that confirm the safety of bearings larger than 36 mm.Assessment of lipped liners is difficult because randomized studies are lacking, but retrospective clinical studies and registry data seem to indicate that this liner modification will reduce the rate of dislocation or revision due to dislocation without clear evidence of clinically obvious problems due to neck-liner impingement.The majority of studies support the view that constrained liners and dual mobility cups (DMC) will reduce the risk of revision due to dislocation both in primary and revision THA, the latter gaining increasing popularity in some countries. Both these devices suffer from implant-specific problems, which seem to be more common for the constrained liner designs. The majority of studies of these implants suffer from various methodological problems, not least selection bias, which calls for randomized studies preferably in a multi-centre setting to obtain sufficient power. In the 2020s, the orthopaedic profession should place more effort on such studies, as has already been achieved within other medical specialties, to improve the level of evidence in the choice of articulation when performing one of the most common in-hospital surgical procedures in Europe. Cite this article: EFORT Open Rev 2020;5:763-775. DOI: 10.1302/2058-5241.5.200002.
Collapse
Affiliation(s)
- Georgios Tsikandylakis
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Region Västra Götaland, Sahlgrenska University Hospital, Department of Orthopaedics, Gothenburg, Sweden
| | - Soren Overgaard
- The Danish Hip Arthroplasty Register, Aarhus, Denmark
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
- Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Johan Kärrholm
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Region Västra Götaland, Sahlgrenska University Hospital, Department of Orthopaedics, Gothenburg, Sweden
- The Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
4
|
Lubchak VV, Sivkov VS, Tsybin AV, Denisov AO, Maligin RV, Shubnyakov MI. [Mid-term and long-term results of metal-on-metal total hip arthroplasty]. Khirurgiia (Mosk) 2019:55-61. [PMID: 31626240 DOI: 10.17116/hirurgia201910155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To assess mid-term and long-term results of metal-on-metal total hip arthroplasty. MATERIAL AND METHODS There were 349 operations for the period 2006-2012 in our clinic. Sixty-four patients underwent a full examination. All patients underwent X-ray examination of the pelvis, MRI of hip joint with metal artifact reduction sequence (MARS). The concentration of cobalt and chromium metal ions was determined in blood serum. Each patient completed a questionnaire (Harris, Oxford, Womac, SF-36). 'Survival' of endoprostheses was calculated using the Kaplan-Meier method. RESULTS According to the Oxford scale, 76.6% of patients had excellent clinical and functional outcomes, 10.9% - good, 9.4% - satisfactory, 3.1% - unsatisfactory. According to the Harris scale, 57.9% of patients had excellent results, 15.6% - good, 7.8% - satisfactory, 18.7% - unsatisfactory. Inclination less than 45 degrees was noted in 77.2% of acetabular components. It is optimal installation angle. According to MRI data, effusion was the main type of periprosthetic changes (16 cases). There were no periprosthetic changes in 33 cases. Pseudotumor was diagnosed in 5 cases. Mean concentrations of cobalt and chromium ions were 1.27 (13.57-0.12) and 0.59 (0.4-0.87) µg/l, respectively. Normal concentration of chromium ions was observed in all cases. Kaplan-Meier survival rate of endoprostheses was 89% (80-97%). CONCLUSION There was no correlation between female sex, young age of patients and incidence of complications. It is necessary to exclude pseudotumor in case of pain syndrome and no signs of aseptic loosening of the components of the endoprosthesis.
Collapse
Affiliation(s)
- V V Lubchak
- Vreden Russian Institute of Traumatology and Orthopedics, Saint-Petersburg, Russia
| | - V S Sivkov
- Vreden Russian Institute of Traumatology and Orthopedics, Saint-Petersburg, Russia
| | - A V Tsybin
- Vreden Russian Institute of Traumatology and Orthopedics, Saint-Petersburg, Russia
| | - A O Denisov
- Vreden Russian Institute of Traumatology and Orthopedics, Saint-Petersburg, Russia
| | - R V Maligin
- Vreden Russian Institute of Traumatology and Orthopedics, Saint-Petersburg, Russia
| | - M I Shubnyakov
- Vreden Russian Institute of Traumatology and Orthopedics, Saint-Petersburg, Russia
| |
Collapse
|
5
|
Lehtovirta L, Reito A, Parkkinen J, Peräniemi S, Vepsäläinen J, Eskelinen A. Association between periprosthetic tissue metal content, whole blood and synovial fluid metal ion levels and histopathological findings in patients with failed metal-on-metal hip replacement. PLoS One 2018; 13:e0197614. [PMID: 29768492 PMCID: PMC5955572 DOI: 10.1371/journal.pone.0197614] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 05/04/2018] [Indexed: 02/08/2023] Open
Abstract
Adverse Reaction to Metal Debris (ARMD) is a major cause of implant failure leading to revision surgery in patients with metal-on-metal (MoM) hip arthroplasties. However, the pathogenesis and its association to implant wear are poorly understood and previous studies have yielded discrepant results. We sought to investigate the associations between histological findings, whole blood and synovial fluid metal ion concentrations and periprosthetic tissue metal concentrations in patients with MoM total hip replacements and hip resurfacings revised for ARMD. 107 hips in total were included in our study. Of these, 87 were total hip replacements and 20 were hip resurfacings, respectively. We found that whole blood, synovial fluid and periprosthetic tissue metal concentrations correlated poorly with histological findings. We suggest that the lack of a clear association between histological findings and wear measures in the present study as well as in previous studies is mostly influenced by variability in patient susceptibility. However, patients presenting with perivascular lymphocytic infiltration had lower chromium concentration in their periprosthetic tissues than patients with no perivascular lymphocytic infiltration. This may reflect the role of metal hypersensitivity in implant failure in these patients. Patients with total hip replacements evinced more necrosis and lymphocytic infiltration in their tissues than patients with hip resurfacings. This suggests that trunnion wear debris is more cytotoxic and/or immunogenic than bearing wear debris leading to higher failure rates seen in patients with total hip replacements.
Collapse
Affiliation(s)
- Lari Lehtovirta
- University of Tampere, Tampere, Finland
- Coxa Hospital for Joint Replacement, Tampere, Finland
- * E-mail:
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | |
Collapse
|
6
|
Tsikandylakis G, Mohaddes M, Cnudde P, Eskelinen A, Kärrholm J, Rolfson O. Head size in primary total hip arthroplasty. EFORT Open Rev 2018; 3:225-231. [PMID: 29951260 PMCID: PMC5994615 DOI: 10.1302/2058-5241.3.170061] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
The use of larger femoral head size in total hip arthroplasty (THA) has increased during the past decade; 32 mm and 36 mm are the most commonly used femoral head sizes, as reported by several arthroplasty registries.The use of large femoral heads seems to be a trade-off between increased stability and decreased THA survivorship.We reviewed the literature, mainly focussing on the past 5 years, identifying benefits and complications associated with the trend of using larger femoral heads in THA.We found that there is no benefit in hip range of movement or hip function when head sizes > 36 mm are used.The risk of revision due to dislocation is lower for 36 mm or larger bearings compared with 28 mm or smaller and probably even with 32 mm.Volumetric wear and frictional torque are increased in bearings bigger than 32 mm compared with 32 mm or smaller in metal-on-cross-linked polyethylene (MoXLPE) THA, but not in ceramic-on-XLPE (CoXLPE).Long-term THA survivorship is improved for 32 mm MoXLPE bearings compared with both larger and smaller ones.We recommend a 32 mm femoral head if MoXLPE bearings are used. In hips operated on with larger bearings the use of ceramic heads on XLPE appears to be safer. Cite this article: EFORT Open Rev 2018;3 DOI: 10.1302/2058-5241.3.170061.
Collapse
Affiliation(s)
- Georgios Tsikandylakis
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Maziar Mohaddes
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Peter Cnudde
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
- Department of Orthopaedics, Prince Philip Hospital, HDUHB, Wales
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Tampere, Finland
- Finnish Arthroplasty Register, Helsinki, Finland
| | - Johan Kärrholm
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Ola Rolfson
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
7
|
Laaksonen I, Galea VP, Connelly JW, Matuszak SJ, Muratoglu OK, Malchau H. Inferior Radiographic and Functional Outcomes With Modular Stem in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2018; 33:464-469. [PMID: 28947371 DOI: 10.1016/j.arth.2017.08.042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2017] [Revised: 08/25/2017] [Accepted: 08/30/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Data on the association between stem type and metal-on-metal (MoM) total hip arthroplasty (THA) performance are limited. The aim of this study is to investigate the effect of stem type on the prevalence of osteolysis and radiolucency, blood metal ion levels, and functional outcomes in patients with Articular Surface Replacement THA (ASR XL), a type of MoM THA. METHODS We analyzed 539 unilateral MoM THAs coupled with Summit (48%), Corail (35%), or S-ROM (17%) hip stems at a mean follow-up of 6.4 years. Fifty-four percent of the patients were male, and the mean age was 60 years. We studied radiographs, patient-reported outcome measures, and ion levels. RESULTS Patients with S-ROM hip stems were 3.8 times more likely to have osteolysis (P = .003) and 7.6 times more likely to have radiolucency (P < .001) than those treated with Summit hip stems. In addition, patients treated with S-ROM hip stems scored worse than those with Summit hip stems in 4 of the 5 patient-reported outcome measures: Harris Hip Score, Visual Analog Scale pain, University of California at Los Angeles activity, and EQ-5D index. All these differences were statistically significant and ranged from 5% to 10%, which is clinically significant. CONCLUSION Patients with S-ROM hip stems had inferior functional and radiographic results compared to patients with Summit hip stems. Retrieval studies on large diameter head MoM THA and close follow-up of these patients with hip stems are needed to understand the mechanism causing the differences in outcomes between these stem types.
Collapse
Affiliation(s)
- Inari Laaksonen
- Department of Orthopedic Surgery, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Vincent P Galea
- Department of Orthopedic Surgery, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - James W Connelly
- Department of Orthopedic Surgery, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Sean J Matuszak
- Department of Orthopedic Surgery, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Orhun K Muratoglu
- Department of Orthopedic Surgery, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Henrik Malchau
- Department of Orthopedic Surgery, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
8
|
Risk factors for mid-term revision surgery in patients with articular surface replacement total hip arthroplasty. Hip Int 2018; 28:44-49. [PMID: 28574125 DOI: 10.5301/hipint.5000524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION This study assessed the associations between gender and implant survival, as well as adverse local tissue reaction (ALTR), in patients with articular surface replacement (ASR) XL total hip arthroplasty (THA). Secondly, we sought to report the differences between genders in metal ion levels and patient reported outcome measures (PROMs) in these patients. METHODS 563 unilateral ASR XL THA patients were enrolled in a multicentre follow-up study at a mean of 6.4 years after index surgery. All patients had blood metal ion levels and PROMs obtained annually, and a valid anteroposterior pelvis radiograph. A sub-set of patients from a single centre had annual MRI performed and were analysed for the presence of moderate-to-severe ALTR. RESULTS 60 hips (11%) were revised during the study period. The only variables found to be associated with revision surgery in patients with unilateral THA were VAS pain (hazard ratio [HR], 1.35; p<0.001) and elevated cobalt metal ion levels (HR, 1.05; p<0.001). No variables assessed were found to be associated with prevalence of ALTR. Chromium concentrations were greater in female patients than males, while cobalt levels were similar between genders. Males reported higher HHS, EQ-5D and UCLA scores than females. CONCLUSIONS Both males and females with metal-on-metal THA implants should be followed with equal vigilance as gender does not appear to be associated with poor outcomes, such as revision surgery and presence of ALTR.
Collapse
|
9
|
Evidence based recommendations for reducing head-neck taper connection fretting corrosion in hip replacement prostheses. Hip Int 2017; 27:523-531. [PMID: 29027189 DOI: 10.5301/hipint.5000545] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/26/2017] [Indexed: 02/04/2023]
Abstract
INTRODUCTION This systematic review seeks to summarise the published studies investigating prosthetic design, manufacture and surgical technique's effect on fretting corrosion at the head-neck taper connection, and provide clinical recommendations to reduce its occurrence. METHODS PubMed, MEDLINE and EMBASE electronic databases were searched using the terms taper, trunnion, cone and head-neck junction. Articles investigating prosthetic design, manufacture and surgical technique's effect on fretting corrosion were retrieved, reviewed and graded according to OCEBM levels of evidence and grades of recommendation. RESULTS The initial search yielded 1,224 unique articles, and 91 were included in the analysis. CONCLUSIONS There is fair evidence to recommend against the use of high offset femoral heads, larger diameter femoral heads, and to pay particular consideration to fretting corrosion's progression with time and risk with heavier or more active patients. Particular to metal-on-metal hip prostheses, there is fair evidence to recommend positioning the acetabular component to minimise edge loading. Particular to metal-on-polyethylene hip prostheses, there is fair evidence to recommend the use of ceramic femoral heads, against use of cast cobalt alloy femoral heads, and against use of low flexural rigidity femoral stems. Evidence related to taper connection design is largely conflicting or inconclusive. Head-neck taper connection fretting corrosion is a multifactorial problem. Strict adherence to the guidelines presented herein does not eliminate the risk. Prosthesis selection is critical, and well-controlled studies to identify each design parameter's relative contribution to head-neck taper connection fretting corrosion are required.
Collapse
|
10
|
Pernaa K, Saltychev M, Mäkelä K. Relationship between Pelvic Incidence Angle and Blood Concentration of Chromium and Cobalt Ions after Metal-on-Metal Hip Replacement: A Brief Report. Scand J Surg 2017; 107:91-94. [PMID: 28931352 DOI: 10.1177/1457496917731182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND AIMS The wear of metal-on-metal hip implants may increase chromium or cobalt ion blood level. This phenomenon may depend among other things on the particularity of spinopelvic anatomy. The effect of pelvic incidence angle on the wear of metal-on-metal hip implants is not known. The objective of the study was to investigate whether such effect does exist. MATERIAL AND METHODS The pelvic incidence and inclination of acetabular component angles of 89 patients after unilateral metal-on-metal hip replacement were compared with blood level of chromium and cobalt ions using Pearson correlation coefficient. RESULTS No significant correlations between pelvic incidence angle and the metal ion blood levels were observed. The correlation coefficients varied from -0.02 to 0.2 and all p values were >0.05. CONCLUSION No evidence was found on the effect of pelvic incidence angle on metal wear after metal-on-metal hip replacement when measured by the blood levels of chromium and cobalt ions. It is reasonable to assume that other factors than pelvic tilt may affect the rate of implant wear.
Collapse
Affiliation(s)
- K Pernaa
- 1 Department of Orthopedics and Traumatology, Turku University Hospital, Turku, Finland.,2 University of Turku, Turku, Finland
| | - M Saltychev
- 2 University of Turku, Turku, Finland.,3 Department of Physical and Rehabilitation Medicine, Turku University Hospital, Turku, Finland
| | - K Mäkelä
- 1 Department of Orthopedics and Traumatology, Turku University Hospital, Turku, Finland.,2 University of Turku, Turku, Finland
| |
Collapse
|
11
|
Laitinen M, Nieminen J, Reito A, Pakarinen TK, Suomalainen P, Pamilo K, Parkkinen J, Lont T, Eskelinen A. High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements. Acta Orthop 2017; 88:269-274. [PMID: 28122467 PMCID: PMC5434594 DOI: 10.1080/17453674.2017.1283846] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood and the rate of revision due to ARMDs in patients treated with MoM hinge total knee arthroplasty (TKA). Patients and methods - 22 patients with TKAs and MoM hinge connecting mechanisms were studied for whole-blood chromium and cobalt levels at 6 months, 1 year, and/or ≥2 years after surgery. Possible ARMDs were investigated by MRI. 12 patients with TKAs and metal-on-polyethylene (MoP) connecting mechanisms served as controls. Results - The cobalt levels were over 5 ppb in 19 of the 22 patients in the MoM group and in 1 of the 12 patients in the MoP group. The chromium levels were over 5 ppb in 11 of the 22 patients in the MoM group and in none of the 12 patients in the MoP group. Pseudotumors were operated in 4 of the 22 patients in the MoM group and in none of the patients in the MoP group. Interpretation - Our results clearly show that the MoM hinge TKA carries a high risk of increased levels of systemic metal ions and also local ARMD, leading to complicated knee revisions. We therefore discourage the use of MoM hinge TKA.
Collapse
Affiliation(s)
- Minna Laitinen
- Department of Orthopedics, Musculoskeletal Surgery Unit, Tampere University Hospital;,Coxa Hospital for Joint Replacement, Tampere;,Correspondence:
| | | | - Aleksi Reito
- Department of Orthopedics, Central Finland Central Hospital, Jyväskylä
| | - Toni-Karri Pakarinen
- Department of Orthopedics, Musculoskeletal Surgery Unit, Tampere University Hospital;,Coxa Hospital for Joint Replacement, Tampere
| | - Piia Suomalainen
- Department of Orthopedics, Musculoskeletal Surgery Unit, Tampere University Hospital
| | - Konsta Pamilo
- Department of Orthopedics, Central Finland Central Hospital, Jyväskylä
| | | | - Tonis Lont
- Coxa Hospital for Joint Replacement, Tampere
| | | |
Collapse
|
12
|
Maurer-Ertl W, Friesenbichler J, Holzer LA, Leitner L, Ogris K, Maier M, Leithner A. Recall of the ASR XL Head and Hip Resurfacing Systems. Orthopedics 2017; 40:e340-e347. [PMID: 27992643 DOI: 10.3928/01477447-20161213-04] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Accepted: 10/31/2016] [Indexed: 02/03/2023]
Abstract
At the beginning of the 21st century, use of large-diameter, metal-on-metal devices was a popular procedure for hip replacement in young and physically active patients; however, within a few years, the number of revisions increased, resulting in a worldwide recall for the articular surface replacement (ASR) system. Complication rates for the ASR devices implanted at the authors' department are reported, with revision rates of 32% and 30% in the ASR XL Head and ASR Resurfacing groups, respectively. Reasons for revision surgery were serum metal ion elevation, luxation or subluxation, aseptic loosening, soft tissue compromise (adverse reactions to metal debris [ARMD]), and infection. The calculated implant survival for the ASR XL Head system and the ASR Resurfacing device (DePuy Orthopaedics Inc, Warsaw, Indiana) in the current series was 79% and 90%, respectively, at 60 months. Symptomatic patients with metal-on-metal devices, with or without elevated metal ion concentrations, should undergo cross sectional imaging to exclude ARMD. In cases of increased metal ion concentrations, local pain, or ARMD, revision surgery has to be evaluated. In the future, closer monitoring of new implants is needed to prevent high failure rates, as seen with the ASR design. Furthermore, the withdrawal of the device highlights the importance of national implant registries. [Orthopedics. 2017; 40(2):e340-e347.].
Collapse
|
13
|
Outcomes of the Recalled Articular Surface Replacement Metal-on-Metal Hip Implant System: A Systematic Review. J Arthroplasty 2017; 32:341-346. [PMID: 27546469 DOI: 10.1016/j.arth.2016.06.060] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Revised: 06/05/2016] [Accepted: 06/27/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of this review was to synthesize the main findings of clinical studies that have evaluated outcomes of the articular surface replacement (ASR) Hip System. METHODS We performed a systematic literature search to identify all articles published between January 2008 and June 2015 that included ASR hip resurfacing arthroplasty (ASR HRA) or ASR total hip arthroplasty (ASR XL THA) outcomes according to the PRISMA statement. RESULTS A total of 56 studies were assessed. The prevalence of adverse local tissue reactions (ALTRs) and revision rates were found to be high. ALTR prevalence varied from 12.5% to 69% (mean, 33.5%). Mean revision rate for any reason at 4-year to 7-year follow-up was 13.8% (range, 5.6%-31%) for ASR HRA and 14.5% (range, 0%-37%) for ASR XL THA. Femoral head size <53 mm was found to correlate with higher blood metal ion levels. Femoral head size >44 mm was not associated with higher ALTR prevalence or revision rates in ASR XL THA. High blood metal ion levels (>7 μg/L Co, >7 μg/L Cr) were associated with higher failure rates and bearing-related complications. The role of cup positioning was found to be controversial. CONCLUSION ALTR prevalence and failure rates were high. High blood metal ion levels were a risk factor for ALTR and failure. Surprisingly, the role of cup positioning and large femoral head size in ASR XL THA were controversial. These findings should be considered in the clinical follow-up and risk stratification of patients with the ASR Hip System.
Collapse
|
14
|
Reito A, Lainiala O, Elo P, Eskelinen A. Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements--The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis. PLoS One 2016; 11:e0147872. [PMID: 26930057 PMCID: PMC4773181 DOI: 10.1371/journal.pone.0147872] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Accepted: 11/25/2015] [Indexed: 11/18/2022] Open
Abstract
Metal-on-metal (MoM) hip replacements were used for almost a decade before adverse reactions to metal debris (ARMD) were found to be a true clinical problem. Currently, there is a paucity of evidence regarding the usefulness of systematic screening for ARMD. We implemented a systematic review and meta-analysis to establish the prevalence of revision confirmed ARMD stratified by the use of different screening protocols in patients with MoM hip replacements. Five levels of screening were identified: no screening (level 0), targeted blood metal ion measurement and/or cross-sectional imaging (level 1), metal ion measurement without imaging (level 2), metal ion measurement with targeted imaging (level 3) and comprehensive screening (both metal ions and imaging for all; level 4). 122 studies meeting our eligibility criteria were included in analysis. These studies included 144 study arms: 100 study arms with hip resurfacings, 33 study arms with large-diameter MoM total hip replacements (THR), and 11 study arms with medium-diameter MoM THRs. For hip resurfacing, the lowest prevalence of ARMD was seen with level 0 screening (pooled prevalence 0.13%) and the highest with level 4 screening (pooled prevalace 9.49%). Pooled prevalence of ARMD with level 0 screening was 0.29% and with level 4 screening 21.3% in the large-diameter MoM THR group. In metaregression analysis of hip resurfacings, level 4 screening was superior with regard to prevalence of ARMD when compared with other levels. In the large diameter THR group level 4 screening was superior to screening 0,2 and 3. These outcomes were irrespective of follow-up time or study publication year. With hip resurfacings, routine cross-sectional imaging regardless of clinical findings is advisable. It is clear, however, that targeted metal ion measurement and/or imaging is not sufficient in the screening for ARMD in any implant concepts. However, economic aspects should be weighed when choosing the preferred screening level.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
- * E-mail:
| | - Olli Lainiala
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| | - Petra Elo
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| |
Collapse
|
15
|
Reito A, Parkkinen J, Puolakka T, Pajamäki J, Eskelinen A. Diagnostic utility of joint fluid metal ion measurement for histopathological findings in metal-on-metal hip replacements. BMC Musculoskelet Disord 2015; 16:393. [PMID: 26693704 PMCID: PMC4687336 DOI: 10.1186/s12891-015-0851-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2015] [Accepted: 11/06/2015] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND In vivo assessment of inflammatory responses in the synovia of patients with MoM hip replacements would be useful in the determination of the prognosis of the hip replacement. Aims of the study was to investigate the correlation between cobalt and chrome levels in joint fluid with histopathological findings and the predictive ability of metal ion levels for these findings. METHODS In 163 revision surgeries (141 ASR THAs and 22 ASR hip resurfacings) joint fluid chrome and cobalt levels were assessed and histological analysis of synovial tissues was performed. Histological analysis included assessment of histiocytes, particle load, surface necrosis, lymphocyte cuffs and ALVAL-score. RESULTS Surface necrosis correlated positively with cobalt levels both in both groups. Neither chrome nor cobalt level had even fair discriminative ability to predict the presence or severity of any histological finding in the THA group. In the hip resurfacing group, cobalt level had good discriminative ability to predict the presence of perivascular lymphocytes and ALVAL-score of ≥ 7 whereas chrome had good discriminative ability to predict surface necrosis, metal particle load and ALVAL-score of ≥ 7. CONCLUSIONS Measurement of metal ion levels following joint fluid aspirate offers no relevant information with regard to histopathological findings in patients with large-diameter MoM THAs. Limited information may be gained from assessment of joint fluid metal ion levels in patients with hip resurfacings, but disadvantages of an aspirate must be carefully reviewed.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33520, Tampere, Finland.
| | | | - Timo Puolakka
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33520, Tampere, Finland.
| | - Jorma Pajamäki
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33520, Tampere, Finland.
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33520, Tampere, Finland.
| |
Collapse
|