1
|
Ayobami OO, Goldring SR, Goldring MB, Wright TM, van der Meulen MCH. Contribution of joint tissue properties to load-induced osteoarthritis. Bone Rep 2022; 17:101602. [PMID: 35899096 PMCID: PMC9309407 DOI: 10.1016/j.bonr.2022.101602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Revised: 06/29/2022] [Accepted: 07/11/2022] [Indexed: 11/27/2022] Open
Abstract
Objective Clinical evidence suggests that abnormal mechanical forces play a major role in the initiation and progression of osteoarthritis (OA). However, few studies have examined the mechanical environment that leads to disease. Thus, using a mouse tibial loading model, we quantified the cartilage contact stresses and examined the effects of altering tissue material properties on joint stresses during loading. Design Using a discrete element model (DEA) in conjunction with joint kinematics data from a murine knee joint compression model, the magnitude and distribution of contact stresses in the tibial cartilage during joint loading were quantified at levels ranging from 0 to 9 N in 1 N increments. In addition, a simplified finite element (FEA) contact model was developed to simulate the knee joint, and parametric analyses were conducted to investigate the effects of altering bone and cartilage material properties on joint stresses during compressive loading. Results As loading increased, the peak contact pressures were sufficient to induce fibrillations on the cartilage surfaces. The computed areas of peak contact pressures correlated with experimentally defined areas of highest cartilage damage. Only alterations in cartilage properties and geometry caused large changes in cartilage contact pressures. However, changes in both bone and cartilage material properties resulted in significant changes in stresses induced in the bone during compressive loading. Conclusions The level of mechanical stress induced by compressive tibial loading directly correlated with areas of biological change observed in the mouse knee joint. These results, taken together with the parametric analyses, are the first to demonstrate both experimentally and computationally that the tibial loading model is a useful preclinical platform with which to predict and study the effects of modulating bone and/or cartilage properties on attenuating OA progression. Given the direct correlation between computational modeling and experimental results, the effects of tissue-modifying treatments may be predicted prior to in vivo experimentation, allowing for novel therapeutics to be developed.
Collapse
Affiliation(s)
- Olufunmilayo O Ayobami
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States of America
| | - Steven R Goldring
- Research Division, Hospital for Special Surgery, New York, NY, United States of America
| | - Mary B Goldring
- Research Division, Hospital for Special Surgery, New York, NY, United States of America
| | - Timothy M Wright
- Research Division, Hospital for Special Surgery, New York, NY, United States of America
| | - Marjolein C H van der Meulen
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, United States of America.,Research Division, Hospital for Special Surgery, New York, NY, United States of America
| |
Collapse
|
2
|
Orozco GA, Tanska P, Gustafsson A, Korhonen RK, Isaksson H. Crack propagation in articular cartilage under cyclic loading using cohesive finite element modeling. J Mech Behav Biomed Mater 2022; 131:105227. [DOI: 10.1016/j.jmbbm.2022.105227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 03/01/2022] [Accepted: 04/02/2022] [Indexed: 11/28/2022]
|
3
|
Henderson BS, Cudworth KF, Wale ME, Siegel DN, Lujan TJ. Tensile fatigue strength and endurance limit of human meniscus. J Mech Behav Biomed Mater 2022; 127:105057. [PMID: 35091175 PMCID: PMC9925119 DOI: 10.1016/j.jmbbm.2021.105057] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 12/06/2021] [Accepted: 12/17/2021] [Indexed: 11/29/2022]
Abstract
The knee menisci are prone to mechanical fatigue injury from the cyclic tensile stresses that are generated during daily joint loading. Here we characterize the tensile fatigue behavior of human medial meniscus and investigate the effect of aging on fatigue strength. Test specimens were excised from the medial meniscus of young (under 40 years) and older (over 65 years) fresh-frozen cadaver knees. Cyclic uniaxial tensile loads were applied parallel to the primary circumferential fibers at 70%, 50%, 40%, or 30% of the predicted ultimate tensile strength (UTS) until failure occurred or one million cycles was reached. Equations for fatigue strength (S-N curve) and the probability of fatigue failure (unreliability curves) were created from the measured number of cycles to failure. The mean number of cycles to failure at 70%, 50%, 40%, and 30% of UTS were estimated to be approximately 500, 40000, 340000, and 3 million cycles, respectively. The endurance limit, defined as the tensile stress that can be safely applied for the average lifetime of use (250 million cycles), was estimated to be 10% of UTS (∼1.0 MPa). When cyclic tensile stresses exceeded 30% of UTS (∼3.0 MPa), the probability of fatigue failure rapidly increased. While older menisci were generally weaker and more susceptible to fatigue failures at high-magnitude tensile stresses, both young and older age groups had similar fatigue resistance at low-magnitude tensile stresses. In addition, we found that fatigue failures occurred after the dynamic modulus decreased during cyclic loading by approximately 20%. This experimental study has quantified fundamental fatigue properties that are essential to properly predict and prevent injury in meniscus and other soft fibrous tissues.
Collapse
Affiliation(s)
- Bradley S. Henderson
- Department of Mechanical & Biomedical Engineering, Boise State University, Boise ID, USA
| | - Katelyn F. Cudworth
- Department of Mechanical & Biomedical Engineering, Boise State University, Boise ID, USA
| | - Madison E. Wale
- Department of Mechanical & Biomedical Engineering, Boise State University, Boise ID, USA
| | - Danielle N. Siegel
- Department of Mechanical & Biomedical Engineering, Boise State University, Boise ID, USA
| | - Trevor J. Lujan
- Department of Mechanical & Biomedical Engineering, Boise State University, Boise ID, USA
| |
Collapse
|
4
|
Ma Z, Huang B, Lu F, Zhao H, Ren L. In Situ Bending Reveals Simultaneous Enhancements of Strength and Ductility of Cortical and Cancellous Layers Induced by the Cartilage Layer. ACS OMEGA 2021; 6:31177-31183. [PMID: 34841160 PMCID: PMC8613877 DOI: 10.1021/acsomega.1c04635] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 11/03/2021] [Indexed: 05/14/2023]
Abstract
The energy absorption and toughening effect of cartilage could effectively protect bone from damage, and the enhancement mechanisms of cartilage on deformation resistance or strength need to be revealed. Using a self-developed in situ bending tester integrated with an optical microscope, in situ bending of the composite bone structure consisting of the cartilage layer and cortical and cancellous layers was carried out, accompanied by simultaneously obtained continuous morphological changes in diverse deformation layers. Although the bending resistance of pure cartilage layer was only 0.3 N, the significant enhancements of bone strength and ductility induced by the cartilage layer were experimentally revealed, as the peak loads and ultimate bending deflections of the composite structure increased by 1.49- to 2.14-fold and 1.43- to 2.12-fold, respectively. The scanning electron microscopy images of the composite bone structure at various locations with disparate stress conditions exhibited significant difference in crack sizes and degrees of tearing damage. The cartilage layer was verified to induce a layered tearing dimple feature to inhibit the crack propagation and further enhance the deformation resistance. The frequency shift comparison between the Raman spectroscopies of various microregions also indirectly verified the inhibition effect of the cartilage layer on the stress increment in the cortical layer.
Collapse
Affiliation(s)
- Zhichao Ma
- School
of Mechanical and Aerospace Engineering, Jilin University, Changchun 130025, China
| | - Bin Huang
- School
of Mechanical and Aerospace Engineering, Jilin University, Changchun 130025, China
| | - Fangzhou Lu
- School
of Mechanical and Aerospace Engineering, Jilin University, Changchun 130025, China
| | - Hongwei Zhao
- School
of Mechanical and Aerospace Engineering, Jilin University, Changchun 130025, China
| | - Luquan Ren
- Key
Laboratory of Bionic Engineering Ministry of Education, Jilin University, Changchun 130025, China
- Weihai
Institute for Bionics-Jilin University, Weihai 264207, China
| |
Collapse
|
5
|
Biomechanical properties of the bone during implant placement. BMC Oral Health 2021; 21:86. [PMID: 33632191 PMCID: PMC7908763 DOI: 10.1186/s12903-021-01442-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 02/14/2021] [Indexed: 11/29/2022] Open
Abstract
Background In this research the biomechanical properties of a bone model was examined. Porcine ribs are used as experimental model. The objective of this research was to investigate and compare the biomechanical properties of the bone model before and after implant placement. Methods The bone samples were divided in three groups, Group 1 where ALL-ON-FOUR protocol was used during pre-drilling and placing the implants, Group 2 where ALL-ON-FOUR protocol was used during pre-drilling, and implants were not placed, and Group 3 consisting of intact bones served as a control group. Static and dynamic loading was applied for examining the model samples. Kruskal–Wallis statistical test and as a post-hoc test Mann–Whitney U test was performed to analyze experimental results. Results According to the results of the static loading, there was no significant difference between the implanted and original ribs, however, the toughness values of the bones decreased largely on account of predrilling the bones. The analysis of dynamic fatigue measurements by Kruskal–Wallis test showed significant differences between the intact and predrilled bones. Conclusion The pre-drilled bone was much weaker in both static and dynamic tests than the natural or implanted specimens. According to the results of the dynamic tests and after a certain loading cycle the implanted samples behaved the same way as the control samples, which suggests that implantation have stabilized the skeletal bone structure.
Collapse
|
6
|
Rahmani Del Bakhshayesh A, Babaie S, Tayefi Nasrabadi H, Asadi N, Akbarzadeh A, Abedelahi A. An overview of various treatment strategies, especially tissue engineering for damaged articular cartilage. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2020; 48:1089-1104. [DOI: 10.1080/21691401.2020.1809439] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Azizeh Rahmani Del Bakhshayesh
- Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Tissue Engineering, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
- Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Soraya Babaie
- Department of Nanotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hamid Tayefi Nasrabadi
- Department of Tissue Engineering, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Nahideh Asadi
- Department of Nanotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Abolfazl Akbarzadeh
- Department of Nanotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ali Abedelahi
- Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Tissue Engineering, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
7
|
Miller RH, Krupenevich RL. Medial knee cartilage is unlikely to withstand a lifetime of running without positive adaptation: a theoretical biomechanical model of failure phenomena. PeerJ 2020; 8:e9676. [PMID: 32844066 PMCID: PMC7414768 DOI: 10.7717/peerj.9676] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 07/16/2020] [Indexed: 01/24/2023] Open
Abstract
Runners on average do not have a high risk of developing knee osteoarthritis, even though running places very high loads on the knee joint. Here we used gait analysis, musculoskeletal modeling, and a discrete-element model of knee contact mechanics to estimate strains of the medial knee cartilage in walking and running in 22 young adults (age 23 ± 3 years). A phenomenological model of cartilage damage, repair, and adaptation in response to these strains then estimated the failure probability of the medial knee cartilage over an adult lifespan (age 23-83 years) for 6 km/day of walking vs. walking and running 3 km/day each. With no running, by age 55 the cumulative probability of medial knee cartilage failure averaged 36% without repair and 13% with repair, similar to reports on incidence of knee osteoarthritis in non-obese adults with no knee injuries, but the probability for running was very high without repair or adaptation (98%) and remained high after including repair (95%). Adaptation of the cartilage compressive modulus, cartilage thickness, and the tibiofemoral bone congruence in response to running (+1.15 standard deviations of their baseline values) was necessary for the failure probability of walking and running 3 km/day each to equal the failure probability of walking 6 km/day. The model results suggest two conclusions for further testing: (i) unlike previous findings on the load per unit distance, damage per unit distance on the medial knee cartilage is greater in running vs. walking, refuting the "cumulative load" hypothesis for long-term joint health; (ii) medial knee cartilage is unlikely to withstand a lifetime of mechanical loading from running without a natural adaptation process, supporting the "cartilage conditioning" hypothesis for long-term joint health.
Collapse
Affiliation(s)
- Ross H Miller
- Department of Kinesiology, University of Maryland, College Park, MD, United States of America.,Neuroscience & Cognitive Science Program, University of Maryland, College Park, MD, United States of America
| | - Rebecca L Krupenevich
- Joint Department of Biomedical Engineering, University of North Carolina, Chapel Hill, NC, United States of America
| |
Collapse
|
8
|
Wasser JG, Acasio JC, Hendershot BD, Miller RH. Single-leg forward hopping exposures adversely affect knee joint health among persons with unilateral lower limb loss: A predictive model. J Biomech 2020; 109:109941. [PMID: 32807307 DOI: 10.1016/j.jbiomech.2020.109941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 06/08/2020] [Accepted: 07/02/2020] [Indexed: 11/16/2022]
Abstract
Single-leg hopping is an atypical, yet convenient, method of ambulation for individuals who have sustained unilateral lower limb-loss. Hopping is generally discouraged by therapists but many patients report hopping, and the potential deleterious effects of frequent hopping on knee joint health remains unclear. Mechanical fatigue due to repeated exposures to increased or abnormal loading on the intact limb is thought to be a primary contributor to the high prevalence of knee osteoarthritis among individuals with unilateral lower limb amputation. We aimed to compare knee joint mechanics between single-leg hopping and walking at self-selected paces among individuals with unilateral lower limb-loss, and estimated the associated probability of knee cartilage failure. Thirty-two males with traumatic unilateral lower limb-loss (22 transtibial, 10 transfemoral) hopped and walked at a self-selected pace along a 15-m walkway. Peak knee moments were input to a phenomenological model of cartilage fatigue to estimate the damage and long-term failure probability of the medial knee cartilage when hopping vs. walking. We estimate that each hop accumulates as much damage as at least 8 strides of walking (p < 0.001), and each meter of hopping accumulates as much damage as at least 12 m of walking (p < 0.001). The 30-year failure probability of the medial knee cartilage exceeded a "coin-flip" chance (50%) when performing more than 197 hops per day. Although a convenient mode of ambulation for persons with unilateral lower limb-loss, to mitigate risk for knee osteoarthritis it is advisable to minimize exposure to single-leg forward hopping.
Collapse
Affiliation(s)
- Joseph G Wasser
- Research and Development Section, Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD, USA; Henry M. Jackson Foundation, for the Advancement of Military Medicine, Bethesda, MD, USA
| | - Julian C Acasio
- Research and Development Section, Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD, USA; Henry M. Jackson Foundation, for the Advancement of Military Medicine, Bethesda, MD, USA
| | - Brad D Hendershot
- Research and Development Section, Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD, USA; DoD-VA Extremity Trauma & Amputation Center of Excellence, USA; Department of Rehabilitation Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Ross H Miller
- Department of Kinesiology, University of Maryland, College Park, MD, USA; Neuroscience & Cognitive Science Program, University of Maryland, College Park, MD, USA.
| |
Collapse
|
9
|
Shaktivesh S, Malekipour F, Whitton RC, Hitchens PL, Lee PV. Fatigue behavior of subchondral bone under simulated physiological loads of equine athletic training. J Mech Behav Biomed Mater 2020; 110:103920. [PMID: 32957215 DOI: 10.1016/j.jmbbm.2020.103920] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 06/02/2020] [Accepted: 06/04/2020] [Indexed: 11/30/2022]
Abstract
Fatigue-induced subchondral bone (SCB) injuries are prevalent among athletes due to the repetitive application of high magnitude loads on joints during intense physical training. Existing fatigue studies on bone utilize a standard fatigue test approach by applying loads of a constant magnitude and frequency even though physiological/realistic loading is a combination of various load magnitudes and frequencies. Metal materials in implant and aerospace applications have been studied for fatigue behavior under physiological or realistic loading, however, no such study has been conducted on biological materials like bones. In this study, we investigated fatigue behavior of SCB under the range of loads likely to occur during a fast-workout of an equine athlete in training. A loading protocol was developed by simulating physiological loads occurring during a fast-workout of a racehorse in training, which consisted of a sequence of compression-compression load cycles, including a warm-up (32, 54, 61 MPa) and cool-down (61, 54, 32 MPa) before and after the slow/fast/slow gallop phase of training, also referred to as a training loop. This loading protocol/training loop was applied at room temperature in load-control mode to cylindrical SCB specimens (n = 12) harvested from third metacarpal medial condyles (MCIII) of twelve thoroughbred racehorses and repeated until fatigue failure. The mean ± standard deviation for total time-to-failure (TTF) was 76,393 ± 64,243 s (equivalent to 18.3 ± 15.7 training workouts) for n = 12 specimens. We observed the highest relative energy loss (REL, hysteresis loss normalized to energy absorbed in a load cycle) under loads equivalent to gallop speeds and all specimens failed under these gallop loads. This demonstrates the importance of the gallop speeds in the development of SCB injury, consistent with observations made in live racehorses. Moreover, specimens with higher mean REL and lower mean stiffness during the first loop had a shorter fatigue life which further confirms the detrimental effect of high energy loss in SCB. Further studies are required to reconcile our results with fatigue injuries among equine athletes and understand the influence of different training programs on the fatigue behavior of subchondral bone.
Collapse
Affiliation(s)
- Shaktivesh Shaktivesh
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia
| | - Fatemeh Malekipour
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia
| | - R Christopher Whitton
- Equine Centre, Melbourne Veterinary School, Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Werribee, 3030, Victoria, Australia
| | - Peta L Hitchens
- Equine Centre, Melbourne Veterinary School, Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Werribee, 3030, Victoria, Australia
| | - Peter Vs Lee
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia.
| |
Collapse
|
10
|
Adebayo OO, Holyoak DT, van der Meulen MCH. Mechanobiological Mechanisms of Load-Induced Osteoarthritis in the Mouse Knee. J Biomech Eng 2020; 141:2736041. [PMID: 31209459 DOI: 10.1115/1.4043970] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Indexed: 12/18/2022]
Abstract
Osteoarthritis (OA) is a degenerative joint disease that affects millions of people worldwide, yet its disease mechanism is not clearly understood. Animal models have been established to study disease progression by initiating OA through modified joint mechanics or altered biological activity within the joint. However, animal models often do not have the capability to directly relate the mechanical environment to joint damage. This review focuses on a novel in vivo approach based on controlled, cyclic tibial compression to induce OA in the mouse knee. First, we discuss the development of the load-induced OA model, its different loading configurations, and other techniques used by research laboratories around the world. Next, we review the lessons learned regarding the mechanobiological mechanisms of load-induced OA and relate these findings to the current understanding of the disease. Then, we discuss the role of specific genetic and cellular pathways involved in load-induced OA progression and the contribution of altered tissue properties to the joint response to mechanical loading. Finally, we propose using this approach to test the therapeutic efficacy of novel treatment strategies for OA. Ultimately, elucidating the mechanobiological mechanisms of load-induced OA will aid in developing targeted treatments for this disabling disease.
Collapse
Affiliation(s)
| | - Derek T Holyoak
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853
| | - Marjolein C H van der Meulen
- Meinig School of Biomedical Engineering, Cornell University, 113 Weill Hall, Ithaca, NY 14853.,Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY 14853.,Research Division, Hospital for Special Surgery, New York, NY 10021 e-mail:
| |
Collapse
|
11
|
The status and challenges of replicating the mechanical properties of connective tissues using additive manufacturing. J Mech Behav Biomed Mater 2019; 103:103544. [PMID: 32090944 DOI: 10.1016/j.jmbbm.2019.103544] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 10/29/2019] [Accepted: 11/16/2019] [Indexed: 01/23/2023]
Abstract
The ability to fabricate complex structures via precise and heterogeneous deposition of biomaterials makes additive manufacturing (AM) a leading technology in the creation of implants and tissue engineered scaffolds. Connective tissues (CTs) remain attractive targets for manufacturing due to their "simple" tissue compositions that, in theory, are replicable through choice of biomaterial(s) and implant microarchitecture. Nevertheless, characterisation of the mechanical and biological functions of 3D printed constructs with respect to their host tissues is often limited and remains a restriction towards their translation into clinical practice. This review aims to provide an update on the current status of AM to mimic the mechanical properties of CTs, with focus on arterial tissue, articular cartilage and bone, from the perspective of printing platforms, biomaterial properties, and topological design. Furthermore, the grand challenges associated with the AM of CT replacements and their subsequent regulatory requirements are discussed to aid further development of reliable and effective implants.
Collapse
|
12
|
Riemenschneider PE, Rose MD, Giordani M, McNary SM. Compressive fatigue and endurance of juvenile bovine articular cartilage explants. J Biomech 2019; 95:109304. [DOI: 10.1016/j.jbiomech.2019.07.048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 07/31/2019] [Accepted: 07/31/2019] [Indexed: 11/24/2022]
|
13
|
Xie S, Manda K, Pankaj P. Effect of loading frequency on deformations at the bone-implant interface. Proc Inst Mech Eng H 2019; 233:1219-1225. [PMID: 31560261 DOI: 10.1177/0954411919877970] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
This study considers the time-dependent behaviour of bone in the context of loosening of metal implants, which is one of the typical complications of joint replacement and fracture-fixation surgeries. We employed viscoelastic properties developed from our previous experimental studies for trabecular bone in a representative bone-implant construct, which was subjected to cyclic loading at varying loading frequencies. We found that the separation between the bone and the implant is a function of loading frequency and increases with number of loading cycles applied. Our analysis shows that at the start of cyclic loading, a higher frequency results in a lower displacement response of bone at the bone-implant interface; however, after the bone-implant system has been subjected to a large number of cycles (>500 cycles in this study), higher interfacial displacements are observed at higher loading frequencies. In other words, higher loading frequencies will not result in bone-implant separation if limited number of cycles are applied. In all cases, interfacial displacements increase as bone volume ratio decreases. This simple approach can be used to evaluate the mechanical environment in bone-implant systems due to cyclic loading which commonly used time-independent models that are unable to simulate. The approach can also be used to evaluate implant loosening due to cyclic loading.
Collapse
Affiliation(s)
- Shuqiao Xie
- School of Engineering, Institute for Bioengineering, The University of Edinburgh, Edinburgh, UK
| | - Krishnagoud Manda
- School of Engineering, Institute for Bioengineering, The University of Edinburgh, Edinburgh, UK
- School of Mechanical and Aerospace Engineering, Queen's University Belfast, Belfast, UK
| | - Pankaj Pankaj
- School of Engineering, Institute for Bioengineering, The University of Edinburgh, Edinburgh, UK
| |
Collapse
|
14
|
Vazquez KJ, Andreae JT, Henak CR. Cartilage-on-cartilage cyclic loading induces mechanical and structural damage. J Mech Behav Biomed Mater 2019; 98:262-267. [PMID: 31280053 DOI: 10.1016/j.jmbbm.2019.06.023] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 05/20/2019] [Accepted: 06/25/2019] [Indexed: 02/01/2023]
Abstract
Cartilage breaks down during mechanically-mediated osteoarthritis (OA). While previous research has begun to elucidate mechanical, structural and cellular damage in response to cyclic loading, gaps remain in our understanding of the link between cyclic cartilage loading and OA-like mechanical damage. Thus, the aim of this study was to quantify irreversible cartilage damage in response to cyclic loading. A novel in vitro model of damage through cartilage-on-cartilage cyclic loading was established. Cartilage was loaded at 1 Hz to two different doses (10,000 or 50,000 cycles) between -6.0 ± 0.2 MPa and -10.3 ± 0.2 MPa 1st Piola-Kirchhoff stress. After loading, mechanical damage (altered mechanical properties: elastic moduli and dissipated energy) and structural damage (surface damage and specimen thickness) were quantified. Linear and tangential moduli were determined by fitting the loading portion of the stress-strain curves. Dissipated energy was calculated from the area between loading and unloading stress-strain curves. Specimen thickness was measured both before and after loading. Surface damage was assessed by staining samples with India ink, then imaging the articular surface. Cyclic loading resulted in dose-dependent decreases in linear and tangential moduli, energy dissipation, thickness, and intact area. Collectively, these results show that cartilage damage can be initiated by mechanical loading alone in vitro, suggesting that cyclic loading can cause in vivo damage. This study demonstrated that with increased number of cycles, cartilage undergoes both tissue softening and structural damage. These findings are a first step towards characterizing the cartilage response to cyclic loading, which can ultimately provide important insight for delaying the initiation and slowing the progression of OA.
Collapse
Affiliation(s)
- Kelly J Vazquez
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Jacob T Andreae
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Corinne R Henak
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA.
| |
Collapse
|
15
|
Mahmood H, Shepherd DET, Espino DM. Surface damage of bovine articular cartilage-off-bone: the effect of variations in underlying substrate and frequency. BMC Musculoskelet Disord 2018; 19:384. [PMID: 30355307 PMCID: PMC6201575 DOI: 10.1186/s12891-018-2305-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2018] [Accepted: 10/15/2018] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Changes in bone mineral density have been implicated with the onset of osteoarthritis, but its role in inducing failure of articular cartilage mechanically is unclear. This study aimed to determine the effect of substrate density, as the underlying bone, on the surface damage of cartilage-off-bone, at frequencies associated with gait, and above. METHODS Bovine articular cartilage samples were tested off-bone to assess induced damage with an indenter under a compressive sinusoidal load range of 5-50 N at frequencies of 1, 10 and 50 Hz, corresponding to normal and above normal gait respectively, for up to 10,000 cycles. Cartilage samples were tested on four underlying substrates with densities of 0.1556, 0.3222, 0.5667 and 0.6000 g/cm3. India ink was applied to identify damage as cracks, measured across their length using ImageJ software. Linear regression was performed to identify if statistical significance existed between substrate density, and surface damage of articular cartilage-off-bone, at all three frequencies investigated (p < 0.05). RESULTS Surface damage significantly increased (p < 0.05) with substrate density at 10 Hz of applied frequency. Crack length at this frequency reached the maximum of 10.95 ± 9.12 mm (mean ± standard deviation), across all four substrates tested. Frequencies applied at 1 and 50 Hz failed to show a significant increase (p > 0.05) in surface damage with an increase in substrate density, at which the maximum mean crack length were 3.01 ± 3.41 mm and 5.65 ± 6.54 mm, respectively. Crack formation at all frequencies tended to form at the periphery of the cartilage specimen, with multiple straight-line cracking observed at 10 Hz, in comparison to single straight-line configurations produced at 1 and 50 Hz. CONCLUSIONS The effect of substrate density on the surface damage of articular cartilage-off-bone is multi-factorial, with an above-normal gait frequency. At 1 Hz cartilage damage is not associated with substrate density, however at 10 Hz, it is. This study has implications on the effects of the factors that contribute to the onset of osteoarthritis.
Collapse
Affiliation(s)
- Humaira Mahmood
- Department of Mechanical Engineering, University of Birmingham, B15 2TT, Birmingham, UK
| | - Duncan E. T. Shepherd
- Department of Mechanical Engineering, University of Birmingham, B15 2TT, Birmingham, UK
| | - Daniel M. Espino
- Department of Mechanical Engineering, University of Birmingham, B15 2TT, Birmingham, UK
| |
Collapse
|
16
|
Orozco GA, Tanska P, Florea C, Grodzinsky AJ, Korhonen RK. A novel mechanobiological model can predict how physiologically relevant dynamic loading causes proteoglycan loss in mechanically injured articular cartilage. Sci Rep 2018; 8:15599. [PMID: 30348953 PMCID: PMC6197240 DOI: 10.1038/s41598-018-33759-3] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Accepted: 10/02/2018] [Indexed: 12/13/2022] Open
Abstract
Cartilage provides low-friction properties and plays an essential role in diarthrodial joints. A hydrated ground substance composed mainly of proteoglycans (PGs) and a fibrillar collagen network are the main constituents of cartilage. Unfortunately, traumatic joint loading can destroy this complex structure and produce lesions in tissue, leading later to changes in tissue composition and, ultimately, to post-traumatic osteoarthritis (PTOA). Consequently, the fixed charge density (FCD) of PGs may decrease near the lesion. However, the underlying mechanisms leading to these tissue changes are unknown. Here, knee cartilage disks from bovine calves were injuriously compressed, followed by a physiologically relevant dynamic compression for twelve days. FCD content at different follow-up time points was assessed using digital densitometry. A novel cartilage degeneration model was developed by implementing deviatoric and maximum shear strain, as well as fluid velocity controlled algorithms to simulate the FCD loss as a function of time. Predicted loss of FCD was quite uniform around the cartilage lesions when the degeneration algorithm was driven by the fluid velocity, while the deviatoric and shear strain driven mechanisms exhibited slightly discontinuous FCD loss around cracks. Our degeneration algorithm predictions fitted well with the FCD content measured from the experiments. The developed model could subsequently be applied for prediction of FCD depletion around different cartilage lesions and for suggesting optimal rehabilitation protocols.
Collapse
Affiliation(s)
- Gustavo A Orozco
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
| | - Petri Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Cristina Florea
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
- Departments of Biological Engineering, Electrical Engineering and Computer Science and Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Alan J Grodzinsky
- Departments of Biological Engineering, Electrical Engineering and Computer Science and Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Rami K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
17
|
Lawless BM, Sadeghi H, Temple DK, Dhaliwal H, Espino DM, Hukins DWL. Viscoelasticity of articular cartilage: Analysing the effect of induced stress and the restraint of bone in a dynamic environment. J Mech Behav Biomed Mater 2017; 75:293-301. [PMID: 28763685 PMCID: PMC5636614 DOI: 10.1016/j.jmbbm.2017.07.040] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2017] [Revised: 07/13/2017] [Accepted: 07/26/2017] [Indexed: 12/04/2022]
Abstract
The aim of this study was to determine the effect of the induced stress and restraint provided by the underlying bone on the frequency-dependent storage and loss stiffness (for bone restraint) or modulus (for induced stress) of articular cartilage, which characterise its viscoelasticity. Dynamic mechanical analysis has been used to determine the frequency-dependent viscoelastic properties of bovine femoral and humeral head articular cartilage. A sinusoidal load was applied to the specimens and out-of-phase displacement response was measured to determine the phase angle, the storage and loss stiffness or modulus. As induced stress increased, the storage modulus significantly increased (p < 0.05). The phase angle decreased significantly (p < 0.05) as the induced stress increased; reducing from 13.1° to 3.5°. The median storage stiffness ranged from 548N/mm to 707N/mm for cartilage tested on-bone and 544N/mm to 732N/mm for cartilage tested off-bone. On-bone articular cartilage loss stiffness was frequency independent (p > 0.05); however, off-bone, articular cartilage loss stiffness demonstrated a logarithmic frequency-dependency (p < 0.05). In conclusion, the frequency-dependent trends of storage and loss moduli of articular cartilage are dependent on the induced stress, while the restraint provided by the underlying bone removes the frequency-dependency of the loss stiffness.
Collapse
Affiliation(s)
- Bernard M Lawless
- Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
| | - Hamid Sadeghi
- Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
| | - Duncan K Temple
- Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
| | - Hemeth Dhaliwal
- Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
| | - Daniel M Espino
- Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK.
| | - David W L Hukins
- Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
| |
Collapse
|
18
|
Sadeghi H, Lawless BM, Espino DM, Shepherd DET. Effect of frequency on crack growth in articular cartilage. J Mech Behav Biomed Mater 2017; 77:40-46. [PMID: 28888932 PMCID: PMC5711256 DOI: 10.1016/j.jmbbm.2017.08.036] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 08/21/2017] [Accepted: 08/25/2017] [Indexed: 11/03/2022]
Abstract
Cracks can occur in the articular cartilage surface due to the mechanical loading of the synovial joint, trauma or wear and tear. However, the propagation of such cracks under different frequencies of loading is unknown. The objective of this study was to determine the effect of frequency of loading on the growth of a pre-existing crack in cartilage specimens subjected to cyclic tensile strain. A 2.26 mm crack was introduced into cartilage specimens and crack growth was achieved by applying a sinusoidally varying tensile strain at frequencies of 1, 10 and 100 Hz (i.e. corresponding to normal, above normal and up to rapid heel-strike rise times, respectively). These frequencies were applied with a strain of between 10–20% and the crack length was measured at 0, 20, 50, 100, 500, 1000, 5000 and 10,000 cycles of strain. Crack growth increased with increasing number of cycles. The maximum crack growth was 0.6 ± 0.3 (mean ± standard deviation), 0.8 ± 0.2 and 1.1 ± 0.4 mm at frequencies of 1, 10 and 100 Hz, respectively following 10,000 cycles. Mean crack growth were 0.3 ± 0.2 and 0.4 ± 0.2 at frequencies of 1 and 10 Hz, respectively. However, this value increased up to 0.6 ± 0.4 mm at a frequency of 100 Hz. This study demonstrates that crack growth was greater at higher frequencies. The findings of this study may have implications in the early onset of osteoarthritis. This is because rapid heel-strike rise times have been implicated in the early onset of osteoarthritis.
Collapse
Affiliation(s)
- H Sadeghi
- Department of Mechanical Engineering, University of Birmingham, B15 2TT, UK
| | - B M Lawless
- Department of Mechanical Engineering, University of Birmingham, B15 2TT, UK
| | - D M Espino
- Department of Mechanical Engineering, University of Birmingham, B15 2TT, UK.
| | - D E T Shepherd
- Department of Mechanical Engineering, University of Birmingham, B15 2TT, UK
| |
Collapse
|