1
|
Wong KW, Wang HW, Chien CS, Li CH, Li CB, Lin CL. Development and verification of a novel bone collector with automatic size separating function for orthopedics surgery. Expert Rev Med Devices 2024; 21:659-666. [PMID: 38884608 DOI: 10.1080/17434440.2024.2367688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Accepted: 06/04/2024] [Indexed: 06/18/2024]
Abstract
BACKGROUND Autologous bone dust can be filled in bone defects to promote effective bone healing but typically it is lost when using suction during surgery. The aim of this study was to develop a novel bone collector that can be used to collect bone chips/dust of varying sizes without changing current surgical procedures. RESEARCH DESIGN AND METHODS This collector was designed to connect to a surgical continuous suction system and comprised a plate filter with a 3 mm hole and featured a taper filter with a mesh size of 0.27 mm for the separation and collection of both coarse and fine bone chips/dust. The bone collector was manufactured using nylon 3D printing and plastic injection with biocompatible materials. RESULTS The bone collector functional test revealed high bone chip collection efficiency (93%) with automatic size separation function. Low (3.42%) filtration errors showed that most of the water can be drained smoothly from the bone collector. In clinical usability testing, bone collectors can provide functions demonstrated in in vivo spinal fusion and femoral fracture surgeries with different bone grafting size requirements. CONCLUSIONS The novel bone collector has been validated as a viable and effective surgical device, offering surgeons an additional option to enhance patient outcomes.
Collapse
Affiliation(s)
- Kin-Weng Wong
- Department of Orthopedic Surgery, Chi-Mei Medical Center, Tainan, Taiwan
| | - Hsuan-Wen Wang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chi-Sheng Chien
- Department of Orthopedic Surgery, Chi-Mei Medical Center, Tainan, Taiwan
| | - Chia-Hsuan Li
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Cun-Bin Li
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chun-Li Lin
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Medical Device Innovation & Translation Centre, National Yang Ming Chiao Tung University, Taipei, Taiwan
| |
Collapse
|
2
|
Sheng XQ, Yang Y, Ding C, Wang BY, Hong Y, Meng Y, Liu H. Uncovertebral Joint Fusion Versus End Plate Space Fusion in Anterior Cervical Spine Surgery: A Prospective Randomized Controlled Trial. J Bone Joint Surg Am 2023; 105:1168-1174. [PMID: 37228228 DOI: 10.2106/jbjs.22.01375] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
BACKGROUND The uncovertebral joint is a potential region for anterior cervical fusion. Currently, we are aware of no clinical trials on human uncovertebral joint fusion (UJF). The purpose of this study was to compare the time it took to achieve osseous union/fusion and the clinical efficacy of UJF to end plate space fusion (ESF)-i.e., traditional anterior cervical discectomy and fusion (ACDF)-in anterior cervical surgery. METHODS Patients with single-level cervical spondylosis were recruited from April 2021 through October 2022 and randomly divided into the UJF and ESF groups, with 40 patients in each group. Autologous iliac bone was used for bone grafting in both groups. The primary outcome was the early fusion rate at 3 months postoperatively. Secondary outcomes included the prevalence of complications and patient-reported outcome measures (PROMs), including the Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), and visual analog scale (VAS) scores for arm and neck pain. RESULTS A total of 74 patients (92.5%) with an average age of 49.8 years (range, 26 to 65 years) completed the trial and were included in the analysis. There was no significant difference between the 2 groups at baseline. The operative duration and intraoperative blood loss were also comparable between the 2 groups. The fusion rate in the UJF group was significantly higher than that in the ESF group at 3 months (66.7% compared with 13.2%, p < 0.0001) and 6 months (94.1% compared with 66.7%, p = 0.006) after the operation. No significant difference was found in the fusion rate between the 2 groups 12 months postoperatively. Overall, the PROMs significantly improved after surgery in both groups and did not differ significantly between the groups at any follow-up time point. The prevalence of complications was not significantly different between the 2 groups. CONCLUSIONS In our study of anterior cervical fusion surgery, we found that the early fusion rate after UJF was significantly higher than that after ESF. LEVEL OF EVIDENCE Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Xia-Qing Sheng
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Yi Yang
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Chen Ding
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Bei-Yu Wang
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Ying Hong
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
- Department of Anesthesia and Operation Center, West China School of Nursing, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Yang Meng
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Hao Liu
- Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
| |
Collapse
|
3
|
Wang S, Fang X, Qu Y, Lu R, Yu X, Jing S, Ding Q, Liu C, Wu H, Liu Y. Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis? Front Surg 2023; 10:1096080. [PMID: 36874465 PMCID: PMC9982008 DOI: 10.3389/fsurg.2023.1096080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 01/11/2023] [Indexed: 02/19/2023] Open
Abstract
Background To assess the clinical and radiographical outcomes of 3-level anterior cervical discectomy and fusion (ACDF) with a 3D-printed titanium cage in treating degenerative cervical spondylosis. Methods In this study, 25 patients with degenerative cervical spondylosis who underwent 3-level ACDF using a 3D-printed titanium cage from March 2019 to June 2021 were retrospectively enrolled. The patient-reported outcome measures (PROMs) were evaluated by visual analog scale (VAS) for the neck (VAS-neck) and arm pain (VAS-arm), Neck Disability Index (NDI) score, Japanese Orthopedic Association (JOA) score, SF-12 concise health survey, and the Odom criteria. The radiographical parameters, including C2-C7 lordosis, segmental angle, segmental height, and subsidence, were assessed. The mean duration of follow-up was 25.6 months. Results Bony fusion was achieved in all patients (100%). In three patients (12%) mild dysphagia was observed during the follow-up. The VAS-neck, VAS-arm, NDI score, JOA score, SF-12 score, C2-C7 lordosis, and segmental angle improved noticeably at the latest follow-up. Based on the Odom criteria, 22 patients (88%) reported satisfactory (excellent or good). The mean loss of C2-C7 lordosis and segmental angle between the immediate postoperative and the latest follow-up values were 1.6° ± 0.5° and 1.1° ± 0.5°, respectively. The mean subsidence was 0.9 ± 0.6 mm. Conclusion In patients with multi-level degenerative cervical spondylosis, 3-level ACDF using the 3D-printed titanium cage can effectively relieve the symptoms, stabilize the spine, and restore segmental height and cervical curvature. It is proven to be a reliable option for patients with 3-level degenerative cervical spondylosis. However, a future comparative study involving a larger population and longer follow-up time may be required to further evaluate the safety, efficacy and outcomes of our preliminary results.
Collapse
Affiliation(s)
- Shanxi Wang
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xuan Fang
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yunkun Qu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Rui Lu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaojun Yu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shaoze Jing
- Department of Orthopedics, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, China
| | - Qing Ding
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Chaoxu Liu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Hua Wu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yang Liu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
4
|
Deng Z, Hu B, Yang X, Wang L, Song Y. The improved bioactive n-HA/PA66 cage versus the PEEK cage in anterior cervical fusion: results from a 6-year follow-up and a case-matched study. BMC Musculoskelet Disord 2022; 23:1113. [PMID: 36544134 PMCID: PMC9768934 DOI: 10.1186/s12891-022-06081-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 12/12/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND The nanohydroxyapatite/polyamide 66 (n-HA/PA66) cage, a bioactive nonmetal cage, is fabricated in a hollow cylindrical shape and has been widely used for decades with good clinical outcomes for anterior cervical fusion. However, there remain some radiological complications, such as a slightly high subsidence rate. To improve the clinical outcomes, the improved n-HA/PA66 cage now has been developed into a trapezoidal and wedge shape, a better biomechanical shape matching the cervical spine that is similar to that of the PEEK cage. However, there have been no long-term comparisons of the improved n-HA/PA66 cage and PEEK cage in anterior cervical reconstruction. METHODS Fifty-eight patients who underwent single-level anterior cervical decompression and fusion (ACDF) with the improved n-HA/PA66 cage (n-HA/PA66 group) were matched with patients with the PEEK cage (PEEK group) by clinical presentation, segment, age and sex. All patients underwent a minimum of 6 years of follow-up. The radiographic parameters (cage subsidence, fusion status, cervical lordosis, and segmental sagittal alignment) and clinical parameters (10-point visual analogue scale, Neck Disability Index and Japanese Orthopedic Association scores) from patients were evaluated before surgery, immediately after surgery, and at the latest follow-up. RESULTS The n-HA/PA66 and PEEK groups were well matched in terms of clinical presentation, segment, age, and sex at surgery. The n-HA/PA66 and PEEK cages had similar fusion rates at 6 months postoperatively (n-HA/PA66: 58.6% vs. PEEK: 51.7%, P = 0.455) and at the last follow-up (n-HA/PA66: 96.6% vs. PEEK: 93.1%, P = 0.402). The respective cage subsidence rates in the n-HA/PA66 and PEEK groups were 6.9 and 12.1% (P = 0.342). The correction of SA was similar between the groups at the final follow-up (n-HA/PA66: 4.29 ± 1.99 vs. PEEK: 3.99 ± 2.59 P = 0.464). There were no significant differences between the two groups in mean cervical lordosis, visual analogue scale scores of the neck and arm, NDI scores, JOA scores or patients' overall satisfaction at the final follow-up. CONCLUSION After single-level ACDF, the improved n-HA/PA66 cage had similar excellent results in both radiological and clinical outcomes compared with the PEEK cage over 6 years of follow-up. According to these results, the improved n-HA/PA66 cage and the PEEK cage could be comparable for ACDF.
Collapse
Affiliation(s)
- Zhipeng Deng
- grid.412901.f0000 0004 1770 1022Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, 610041 Sichuan China
| | - Bowen Hu
- grid.412901.f0000 0004 1770 1022Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, 610041 Sichuan China
| | - Xi Yang
- grid.412901.f0000 0004 1770 1022Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, 610041 Sichuan China
| | - Lei Wang
- grid.412901.f0000 0004 1770 1022Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, 610041 Sichuan China
| | - Yueming Song
- grid.412901.f0000 0004 1770 1022Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, 610041 Sichuan China
| |
Collapse
|