Foukas AF, Hadjimichael AC, Nicolaou C, Savvidou OD, Papagelopoulos PJ. A 3D-printed load sharing implant achieved union of a 9-cm femoral segmental bone defect within three months using a hybrid Masquelet induction membrane technique. A case-report.
Trauma Case Rep 2024;
49:100978. [PMID:
38312114 PMCID:
PMC10835288 DOI:
10.1016/j.tcr.2024.100978]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/15/2024] [Indexed: 02/06/2024] Open
Abstract
Case
A 30-year-old male was admitted in our hospital having an open left distal femoral fracture with 9-cm segmental bone defect and a closed proximal left tibial fracture. He was treated successfully using a Hybrid (Titanium Cage and Bone Graft) Masquelet Induction Membrane Technique (MIMT). His femoral fracture united 3-months post - operatively. The left tibia was treated initially with two locking plates. Following infection, a 3-cm tibial bone gap was treated with external fixation and conventional MIMT. The tibial fracture united 12-months post- operatively.
Conclusion
The Hybrid MIMT achieved a successful healing outcome in this challenging case.